Home

VP107 User manual

image

Contents

1. non adjustable at the maximum volume level Tuning the volume control varies only the voice message volume level Time Out Auto Reset This feature allows the VP107 to be automatically reset after a predetermined amount of time This places the VP107 back in standby mode to help The VP107 has following programmable options Priority scan Non priority scan Silent scan Alert duration Priority alert Reset options Carrier reset Delayed N carrier Reset Manual Reset Revert Reset Time out Reset Delayed N revert Reset Stored voice options Max message lengths call reminder Push to listen Battery life 13 Battery life depends upon the number of calls received and length of each call capacity and charge of the battery and the mode of operation A battery gauge will be showed on the green LED located between the knobs on top of the pager can be used to determine remaining battery capacity To enable the battery gauge press the reset button or rotate function switch This will illuminate the LED in the battery gauge by flash times The green LED on the top of the pager show remaining battery strength Flash Green LED 3 time full capacity Flash Green LED 2 time 2 3 capacity Flash Green LED 1 time 1 3 capacity Flash RED LED low battery 14 Accessories Gold Apollo offers these accessories below to increase communications efficiently and provide many unique benefits 5 5V 1A Po
2. by either incoming new messages replacing older messages or by turning the VP107 off Unread Message Indicator The red LED turns on if there are any unread messages Reminder Alert The pager generates a reminder alert approximately every two minutes when an unread message exists Voice Memo When the VP107 is powered on or the function select switch is moved to a new position a voice prompt will be played to announce the mode that the pager is in This feature is available with the stored voice pagers only and can be disabled through the programming software 10 Stored Voice Operation Selective Call Position In this position the message is simultaneously stored as you receive the voice communication The message recording cycle is complete under any of the following conditions When the maximum message length is complete When the squelch circuit no longer detects carrier signal When the delayed N cycle is complete When the timed out reset cycle is complete Reminder Alert The pager generates a reminder alert approximately every two minutes when an unread message exists Voice Memo When the VP107 is powered on or the function select switch is moved to a new position a voice prompt will be played to announce the mode that the pager is in This feature is available with the stored voice pagers only and can be disabled through the programming software If channel traffic occurs after the page and messa
3. is sounded until the decoder circuit power up is complete Thereafter whenever a properly encoded message is received the red LED flashes and an audio alert is sounded If the battery voltage falls below the level required for operation a low battery pulse tones sounds and the red LED Power LED of Battery Alert Indicators flashes to indicate a low battery state Product Overview 3 Function Switch According to the specific model ordered the function switch will be configured to 4 positions Different function modes monitor selective call scan etc can be configured for any position of the switch Channel Monitoring When the function switch is set to a monitor position all voice communications on the selected channel is heard through the speaker When monitoring channel 1 or 2 all ordered alert options are functional Reset Button After receipt of a properly coded message and after completion of that message the VP107 will automatically reset to the programmed operational mode see reset on pager 2 options Some of these reset functions will place the pager in the monitor mode In these cases or when the manual reset function is programmed into the pager press the reset button to return your VP107 to the standby mode External Speaker Jack When the VP107 is used in high noise environments or when privacy is needed an optional Gold Apollo approved lapel speaker or earpiece can be connected to the external access
4. If the VP107 is programmed for priority scan the requency programmed as frequency 1 F1 is designated as the priority channel If thereis no traffic on F1 the VP107 alternately listens to F1 and F2 Frequency 2 until a transmission is detected on F1 the VP200 VP200pro stays on that channel until he transmission ceases The VP107 only decodes tones on F1 channel No tones are decoded on the F2 channel Ifthe VP107 detects a transmission on F2 it stops on F2 then listens for transmissions on F1 Scan back time is programmable and can be set to 0 5 1 or 2 second increments If a transmission is detected on F1 the VP107 switches to F1 cutting off any ransmission on F2 When switching from F2 to F1 the VP107 listens for any tones and alerts if the proper tones are detected It should be noted that the detection of tones is very dependent on the duration of the tone sent over the air To ensure reliable alerting it is recommended that this feature only be used when the first tone duration transmitted is one second or more Scan Operation 7 Non priority Scan Normal Scan If the non priority scan mode the VP107 alternately listens on F1 and F2 for any transmission A transmission on either channel causes the VP107 to stop on that channel until the signal disappears In non priority scan the VP107 decodes tones on either F1 or F2 provided the VP107 has listened to the appropriate channel at the correct time However it should be
5. Voice Pager VP 107 User Manual Contents Product Overview ees ese ee ke ke ee 1 Operations ER EE ER EG ed 4 Scan Operatii mssi naa 6 Features And Control 9 Stored Voice Operation ee ee 10 Fiele Installed Options ke 12 Battery lila adi nin 13 Accessories Product Overview 1 Product Overview On Off Switch Function Switch volume control Green Red Charging LED C gt Amber External Accessory jack Plugged Reset Button NOTE To prevent entry of PlayBack Button dust and moisture the plug should be inserted whenever the external accessory jack is not being used 2 Product Overview VP107 Function description ON OFF Switch Volume Control The ON OFF SWTCH VOLUME CONTROL is a combined single control located on the top of the VP107 Turning the control knob a few degrees in a clockwise direction applies power to the receiver and an audible beep is sounded to indicate that the VP107 is turned on As the control is rotated in a clockwise direction the volume level of any received message and alert tone is increased Rotating the control in the opposite direction reduces the audio level and turns the VP107 Off Audible Visual Alert Indicators When your VP107 is initially turned on both the red and a green LEDs on the control panel light and an alert tone
6. ge and before carrier signal is lost that will also be stored in memory After storage is complete and carries drops the VP107 responds according to the programmed reset mode the VP107 can be reset by pressing the RESET button at any time Stored Voice Operation 11 Scan Monitor PositionsIn these positions the message is stored only when a properly encoded message is received Other communications monitored on the channel that do not alert your monitor are not stored Selective Playback of Message s To playback a particular message in memory press the PLAYBACK button Pressing once replays the newest message in memory Twice replays the second most recent message and so on Messages cannot be played back during message recording You may also playback older messages by pressing the PLAYBACK button as you are listening to a message If you are listening to the most recent message and want to listen to an older message press the PLAYBACK button while listening to the current message The playback switches to an older message if it is still in storage lf there are no messages in memory a memory empty one short beep tone is heard while the PLAYBACK button is pressed NOTE A message is considered read if playback has been initiated for the end of the message is reached whichever occurs 12 Fiele Installed Options Fixed Alert Audio Only Volume Control When this option is installed the alert tone is factory preset
7. noted that if the VP107 is listening to traffic on F2 and an alert is transmitted on F1 the VP107 will not hear that signal until the transmission on F2 is finished Therefore an emergency alert could be missed if the VP107 is listening to traffic on one channel with tones being sent out on the other channel 8 Scan Operation Silent Scan In the silent scan mode the VP107 alternately listens on F1 and F2 for transmissiion and alert tones Tone A Detection of alert tones on each channel causes the VP107 to stop on that channel until the signal disappears In the silent scan mode the VP107 decodes tones on either F1 or F2 provided the VP107 has listened to the appropriate channel at the correct time However it should be noted that if the VP107 is listening to traffic on F2 and an alert is transmitted on F1 the VP107 will not hear that signal until the transmission on F2 is finished Therefore an emergency alert could be missed if the VP107 is listening to traffic on one channel with tones being sent out on the other channel Scan back time is programmable To ensure reliable alerting it is recommended that this feature only be used when the first tone duration transmitted is one second or more Deleting Messages 9 The VP107 that includes the stored voice feature can store up to 8 minutes of voice messages The VP107 can be programmed for stored voice fixed message lengths of 15 30 60 or 120 seconds Messages can be deleted
8. ory jack located at the bottom of the VP107 The jack is fitted with a protective plug 4 Operation Perform the following steps to prepare your VP107 for operation 1 2 Set the FUNCTON switch to a tone alart position Rotate the ON OFF SWITCH VOLUME CONTROL clockwise to turn on the VP107 Four short beep sounds occur and both LEDs light indicating that power is applied Set the FUNCTION switch to a monitor position Listen for a transmission and adjust the volume control to a comfortable listening level If no transmimssion is heard hold down the RESET button and adjust the background noise to a comfortable listening level It may be necessary to readjust the volume when a voice signal is present Set the FUNCTION switch to the desired operating mode i e selective call tone selective call vibrate monitor scan etc Turn off the VP107 by rotating the ON OFF SWITCH VOLUME CONTROL counterclockwise until a click is heard and the mechanical stop is reached Operation 5 Belt Clip Feature An integral part of the clip on the back of your VP107 is a security hook This hook is intended to allow easy removal of the VP107 while at the same time preventing the unit from being pulled off your belt Scan function Two Frequency Models Only All VP107 that are equipped with two frequencies are capable of scanning the two channels for selective call or monitoring purposes 6 Scan Operation Priority Scan
9. wer Adapter Micro USB Battery Charging Description When USB plug insert to the USB jack of the VP107 it will start charging and turn on the Charging LED when it fully charged the charging LED will be turned off A G3 USB Jack Make sure to read this manual before using the machine Please keep it in hand for future reference