1. 10 1 Once the power is applied three beeping sounds can be heard and the LED toggles the color to red green red indicating that the reader is in standby mode after a successful initialization and diagnostics 10 2 Present proximity card to the reader until you hear a beep sound The LED is changing the color to Green simultaneously and sends the RF card data to the controller Afterwards the LED changes the color to red again for the next reading 10 3 LED Control To change the LED colors you may connect the LED Control Input Yellow wire to power ground The green LED is indicating that the reader is in standby mode Present proximity card The LED changes the color to red simultaneously then to green again for the next reading 10 4 Buzzer Control When the reader reads the proximity card one beep sound generates in normal operation mode but you can generate more beep sounds to distinguish whether the access is granted or denied To generate more beeps you may control the Buzzer Control Input Blue wire to power ground Afterwards you can turn the beeper on while holding the Buzzer Control Input to power ground 10 5 Wiegand ABA Track II Output Format Select When you remain open circuit of Wiegand ABA select input Brown wire then the reader will generate 26bit Wiegand output When you want ABA Track Il Magstripe output then connect Wiegand ABA select input Brown wire to system ground level connect this wire to Black w
2. b p 4 31cm Q adu X 8 38cm 1 9 hole ye SN o uds ud ME eps a d z 6 32 hol non a x T x BOTTOM Reader Module gt 2 Reader Module gt p CN C raar MA gerens iPASS 6 32 or MI3 screws Wall Mount Mullion Mount s Electric Gangbox Mount Bezel IDTECK 8 Wire Color Table of the Reader iPass P10 20 SIGNAL COLOR Main Power 12V Red Power Ground GND Black Wiegand ABA Track Il Out Select In Brown ABA Track Il CP Out Orange Wiegand Data 0 Out ABA Track Il Data Out Green Wiegand Version Wiegand Data 1 Out ABA Track II Clock Out 3 RS232 Version Optional RS232 TX Buzzer Control In Blue LED Control In Yellow Please cut the connector off the end of the cable before installation Brown Orange and Green wires are not used for RS 232 version of IP 10 20 9 Wire Connection to Controller ABA or Wiegand Applicable to IP10 20 with Wiegand option ALLE Optional Orange ABA Track Il CP Out Green ABA Track Il Data Out Wiegand Data 0 Out Buzzer Control In Yellow White ABA Track Il Clock Out Wiegand Data 1 Out LED Control n TENUENURENTIUSUTSTEPUEROEUUUEENI J H Brown Wiegand ABA Out Select In RS232 Applicable to 1P 10 20 with RS232 option To use these options White RS232 TX connect each wire to the GND IP1 0 20 Red DC12V Black GND Power iPAss IP10 20 10 Operation
3. basement or swimming pool 5 This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company 6 Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c If the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d If the product exhibits a distinct change in
4. of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR OTHER LOSS AND IDTECK S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT To obtain repair or replacement under the terms of this warranty visit IDTECK s Website http www idteck com and place an online RMA request After an RMA code is issued return the product along with the authorization RMA code Warranty Period Warranty item Period 1 RF READER FINGERPRINT READER 2 RF CARD Active type 3 STANDALONE CONTROLLER 2 years 4 CONTROL PANEL 5 FINGERPRINT CONTROLLER MOLDED RF READER 6 RF10 RF20 RF30 RF TINY IP10 IP20 IP30 SR10E SR10UE SR10SE SR10RWE SR10BE Lifetime RF CARD Passive type T IDC80 IDC170 IDK50 IMC125 LXK50 IPC80 IPC170 IPK50 ISC80 ISC80S ISK50 IMC135 IHC80 IP100 IP200 10 iPAss IP10 20 RMA REQUEST FORM IDTECK accepts only on line RMA requests on our Website www idteck com Please provide us with basic information in the below form so that we can understand your problems better send us back this form with your products after an RMA code is issued on our Website This form is not compulsory Authorization RMA Code 1 Company Na
5. performance wo N 2 General The iPASS IP10 20 Reader is an elegant looking reader which can be mounted to metal door frame mullion or any flat wall surface The iPASS IP 10 20 Reader uses an electronic module in epoxy potting that ensures successful operation even in harsh environments Two color LED green and red and built in beeper sound provides accurate and reliable system operations There are two output formats of 26bit Wiegand output and ABA Track II Magstripe output available and the user can select the output format as they want 3 iPAss IP10 20 3 Features 125KHz Proximity Card Reader ASK EM Format Read Range Up to 4inch 10cm User Format Available 26bit Wiegand Default ABA Track Il and RS232 Optional Output Format Dual Reading Technology Reader Active and Passive Cards Easy to Install on Metal Door Frame or Mullion IP10 and Wall Mount IP20 Suitable External LED Control and External Buzzer Control Solid Epoxy Potted Waterproof IP65 IP66 Reverse Polarity Protection Options Supervisory Signal 4 Identifying Supplied Parts Please unpack and check the contents of the box Li TZEE Reader Module IPASS IP10 IP20 Bezel User s Manual lea lea 1copy 5 opecification Model IPK50 Up to 2 inch 5cm ies eese IPC170 IPC180 Up to 4 inch 10cm 30ms InputPot 2ea Exteral LED Control External Buzzer Control 26bit Wiegand Default R
6. S232 and ABA Track II Optional 2 Color LED Red and Green Piezo Buzzer Piezo Buzzer Operating 5 5 Operating Humidi 10 to 90 relative humidity non condensing Color Material Dark Pearl Gray Polycarbonate Dimension 46mm x 122mm x 23mm 76mm x 124mm x 23 5mm IDTECK pass P10 20 W xH x T 3 x 4 89 x 0 87 Weight 160g 0 35lbs 185g 0 41lbs Life time LOU Wo s Index of Protection IP65 IP66 Certification UL FCC CE MIC 6 Check Points and Tip Recommended cable type and permissible length of cable Description Cable Specification Distance Belden 9512 22 AWG Reader Power and Data 4 conductor shielded 150m Reader gt ACU Belden 9514 22 AWG 8 conductor shielded Need thicker wire if you connect the reader with high current consumption Reader connection If you install the reader in a long distance between the ACU and the reader you have to remind that there will be a voltage drop between both ends of GND wire For example if you connect a reader with 100mA current consumption at 100m distance assume to using DC resistance of cable of 100 0 100m and the reader power is supplied from the ACU the voltage drop of the GND wire will be 1V In this case the Wiegand data signal can not be measured lower than 1V The most of ACU is capturing the signal by the voltage level of data input and 1V is the critical point whether the ACU read the data logic 1 or l
7. User s Manual iPASS P10 20 ASK EM Format Proximity Card Reader iPAss IP10 20 Table of Contents Tee IMIPOMENT Sally SUUCHONS ecoute RU tr oues me ede tta etuer 3 a EIE 2 ee 3 FOIOS aardman i e a tat tates ease encanta ania aod 4 4 Identifying Supplied Parts ccc ccccscsssssssesssssesssesseesseseesssesseseseseesseesessaeeeeens 4 mole se UON NN E E E D DET 4 OCG FONS IPO HDi Ge euntdcoi a Srt tuni riu I 9 MMS CAN lier ER 6 8 Wire Color Table of the Reader isst iulitu Pre tuslentesut pner ameta kae desta inum onm un T 9 Wire Connection to CODIFOIIGE saccos netto itte tuv t ach tarta petens T ODAU a AE m 8 11 FOC Registration Information eeeennnnn 9 12 Warranty Policy and Limitation of Liability sessesssss 10 IDTECK aPASS P10 20 1 Important Safety Instructions When using your ASK EM Format Proximity Reader basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following should also be followed Read and understand all instructions Follow all warnings and instructions marked on the product Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap 4 Do not use this product near water such as bath tub wash bowl kitchen sink laundry tub in a wet
8. interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help IDTECK aPASS P10 20 12 Warranty Policy and Limitation of Liability IDTECK warrants this product against defects in material and workmanship for the period specified below from the date of purchase under normal customer use This Warranty doesn t apply 1 to any product which has been dismantled without authorization of IDTECK or and has a damaged or detached QC label on its back side 2 to any losses defects or damages caused by improper testing operation installation maintenance modification alteration or adjustment 3 to any product with a damaged or faded serial number on it or 4 to any losses defects or damages caused by lightning or other electrical discharge natural disaster misuse accident or neglect This Limited Warranty is in lieu of all other warranties obligations or liabilities on the part of IDTECK and IDTECK DISCLAIMS ANY AND ALL WARRANTY WHETHER EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure
9. ire then the reader will generate ABA Track II output After you select output format preferred output format will be selected after the power on reset Both 26bit Wiegand and ABA Track Il Magstripe outputs are all pulled up to 5V DC by 1K ohm pull up resistors IDTECK iPass P10 20 11 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the responsible for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct
10. me 2 Model Name 3 Serial No 4 Original Invoice No 9 Distributor 6 Purchasing Date 7 RMA Request Date Please check your problems o Card Reading o Power o Keypad o Communication o Relay o LCD o LED amp Buzzer o Registration o Others IDTECK RMA Center gt gt 3F 10 10 1 10 2 Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 157 030 Korea Telephone 82 2 2659 0055 HQ 82 32 671 5642 RMA Center Fax 82 2 2659 0086 HQ 82 32 671 5641 RMA Center Website www idteck com e Training Center www idtecktraining com 11 iPAss IP10 20 The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com MARIPASHE 2X May 2008 Copyright OIDTECK Co Ltd
11. ogic 0 therefore the reader output can not be read correctly from the ACU You have to think about how you reduce the voltage drop between both ends of GND wire There will be two methods to reduce the voltage drop and ACU can read data correctly B Reduce the DC resistance of GND wire Using thick cable or add more wires to GND wire in parallel If you connect 4 wires in parallel for GND the DC resistance of GND wire will be reduced to 1 4 of single wire m Use separate power for the reader Disconnect 12V wire from the ACU and connect external power supply to the reader nearby then there will be no current flow through the GND wire and no voltage drop between both ends of GND wire RF Reader ACU Reader connection using additional wires 5 IDTECK aPASS P10 20 RF Reader lt Reader connection using external power supply gt T Installation 7 1 Mullion Wall Mount Drill two 6 32 or M3 holes 3 3 8 38cm apart in vertical and drill one 1 2 hole for the reader cable 1 7 4 31cm apart from the top hole Skip this step if you have installed an electric gang box 1 2 Put reader cable into the center hole and install the reader module by using two 6 32 or M3 screws Not included 7 3 Put bezel on to the reader module Then push bezel until you hear the locking sound 7 4 To detach the bezel hold both sides of the bezel push the bezel to the bottom and pull the bezel forward TOP 6 32 hole oO