Home
Compressor EasyAir 15 Manual
Contents
1. Medical Inc shall upon written notifi cation thereof and substantiation that the goods have been stored installed maintained and operated in accordance with Precision Medical Inc s instructions and standard industry practice and that no modifications substitutions or alterations have been made to the goods correct such defect by suitable repair or replacement at its own expense ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES The representatives of Precision Medical Inc or any retailers are not authorized to make oral warranties about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive statement of the terms of that contract THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY WHETHER EXPRESS OR IMPLIED Precision Medical Inc shall not under any circumstances be liable for special incidental or consequential damages including but not limited to lost profits lost sales or injury to person or property Correction of non conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical Inc whether based on contract negligence strict tort or otherwise Precision Medical Inc reserves the rightto discontinue manufacture of any product or change product materials desig
2. can result in a risk of electrical shock AWARNING Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked Hospital Grade IMPORTANT SAFEGUARDS When using electrical products especially when children are present basic safety precautions should always be followed including the following READ ALL INSTRUCTIONS BEFORE USING Read and understand this manual before using the product This manual is provided for your safety and to prevent damage to the product If there is anything you do not understand do not use the product contact your Equipment Provider ADANGER TO REDUCE THE RISK OF ELECTROCUTION Always unplug product immediately after using DO NOT use while bathing DO NOT place or store product where it can fall or be pulled into a tub or sink DO NOT place or drop into water or other liquid DO NOT reach for a product that has fallen into water Unplug immediately EASY AIR 15 ADANGER e DO NOT attempt to repair product Any attempt could result in electrical shock e Never use near any type of flame or flammable explosive substances e Caution must be exercised when using this product where oxygen is being administered e Never allow product to exceed Operating or Storage Temperature specifications AWARNING TO REDUCE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS e The product should never be left unattended when produc
3. EASY AIR 15 Models PM15F shown PM15P SAVE THESE INSTRUCTIONS ACAUTION Federal USA law restricts this device to sale by or on the order of a physician PRECISION MEDICAL 300 Held Drive Tel 610 262 6090 Northampton PA 18067 Fax 610 262 6080 CONTENTS SAFETY SYMBOL DEFINITIONS c ccccccsesssecesecesessseeeeeeessssseeeeeeeseeaes 1 RECEIVING INSPECTION c sssssssssssssessessssssscssessesssssssessesssssssesseeseceseesseessesseesseeseesseesnees 2 SPECIFICATIONG csssssssssssesssssssessessesssssssessssssessnessssussssessessucssesssesucsneesnesscsueessesseesseensesss 2 INTENDED USE e E E E E EE EET 2 GROUNDING INSTRUCTIONS c scscsssssssssssssessssssesssessesssssseessessssssesssesssessessnesseesseessesss 3 SAFEGUARDS zarren E E E p E EE AS E 3 WARNINGS virsiin iiaeiai afeti aaant iia aditi annia 4 COMPONENT IDENTIFICATION c ssssssssssssssessesssssssessssssesssessessssssessseesssssecsneeseesseeseenss 5 OPERATING INSTRUCTIONS csssscssessssssssssessesssesssesssssssseessesscssessseessessessnesseesseenseess 6 CLEANING MAINTENANCE c csccssscssessesssssssessesssesssessssssesseessesssssesssesssessecsneeseesseensesss 7 REPLACEMENT PARTS LIST ccccsesecececesessseseseceseeeeeeeeeseeeeeeeeeeseaaes 8 RETURNS isccisvecsiesevtecnscctteceecedtvenss E EEE A E E os eaidrataneedanienci 8 TROUBLESHOOTING scssssssssssssssssssssssessessssssesssessessusssseesessse
4. OTING If the Easy Air 15 Compressor fails to function consult the Troubleshooting guide below AWARNING There are no user serviceable parts inside To avoid injury DO NOT open cabinet If the problem cannot be corrected consult your Equipment Provider or Precision Medical Inc Problem Probable Cause Remedy A Product does not 1 On Off Switch in Off Push On Off Switch operate position to On position 2 Power Cord not 2 Check Power Cord connected properly connections 3 Product overheated 3 Shut product Off Wait 15 minutes Ensure vents are clear Replace Fuse Turn off product When Power restored repeat Start Up Procedure e 4 Blown Fuse 5 Power Interruption B Unable to adjust 1 Locked Regulator pressure flow Knob C Overheating 1 Poor Ventilation ol 4 Pull Regulator Knob out Move product to a cooler better ventilated area Clean Air Filters N 2 Dirty Air Filters D Low pressure flow 1 Loose connection at outlet fitting 2 Improper regulator 2 Re adjust regulator adjustment Tighten connection EASY AIR 15 m AND LIMITATION OF LIABILITY Precision Medical Inc warrants that EASY AIR 15 Compressor the Product will be free of defects in workmanship and or material for the following period One 1 year from shipment Should any failure to conform to this warranty appear within the applicable period Precision
5. filters to their original locations CAUTION e Excessive dust buildup on external filters will reduce performance of product If this occurs clean or replace with new filters e The Air Filter on top of the compressor does not filter out saline Treatments using nebulized saline will draw the saline mist back into the product Saline causes rapid deterioration of the compressor seals and will void the warranty AS NEEDED Clean exterior surfaces with a cloth or sponge dampened with soap and water Wipe dry with a clean cloth or paper towel AWARNING e DO NOT immerse product in liquid If product is used for treatment of infectious disease consult your physician or healthcare professional for recommended cleaning procedures EASY AIR 15 AT 8500 HRS Return product to Equipment Provider for compressor maintenance including rebuilding pump Call Precision Medical Inc for Preventative Maintenance Services REPLACEMENT PARTS LIST 503237 Filter Large 502391 Filter Small 502597 User Manual RETURNS Refer to Precision Medical Inc s Return Policy at www precisionmedical com or contact Precision Medical Inc Note When returning this product disconnect the power cord from the back of the unit MAINTENANCE RECORD Unit Serial No In Service Date Date Hours Maintenance Performed EASY AIR 15 TROUBLESHO
6. ns or specifications without notice Precision Medical Inc reserves the right to correct clerical or typographical errors without penalty EASY AIR 15 10 Contact your Equipment Provider for replacement parts and accessories Your Equipment Provider is PRECISIONE MEDICAL Precision Medical Inc 300 Held Drive Northampton PA 18067 USA Toll Free Tel 800 272 7285 Toll Free Fax 800 352 1240 Tel 610 262 6090 Fax 610 262 6080 Visit us on the Web www precisionmedical com 502597 Rev 7 10 06 M PRINTED IN USA
7. ons Length 16 40 6 cm Width 74 18 4 cm Height 1014 26 0 cm Weight 20 4 Ibs 9 3 kg Shipping Weight 241lbs 10 9 kg Electrical PM15F amp PM15P 108 132 VAC 60 Hz 5 Amps Operating Temperature Range 50 F to 104 F 10 C to 40 C Storage Temperature Range 4 F to 104 F 20 C to 40 C Storage Operating Humidity Maximum 95 Non condensing Outlet Grounded 9 16 18 Male Threaded Fitting Safety Systems High Temperature Motor Shutdown Thermal Protector Class B Thermal Limit Automatic Reset Equipment Classification Class with respect to protection from electrical shock Type B degree of protection against electrical shock IPXO degree of protection against ingress of liquids Mode of Operation continuous This device meets the EMC requirements of EN 550011 1998 Group 1 Class B This device meets the requirements of CGA V 5 2005 section 5 4 This product is not suitable for use in the presence of a flammable anesthetic mixture with air with oxygen or with nitrous oxide EASY AIR 15 GROUNDING INSTRUCTIONS The product should be grounded In the event of an electrical short circuit grounding reduces the risk of electrical shock by providing an escape wire for the electrical current This product is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded ADANGER Improper use of the grounding plug
8. r any device labels are missing or illegible contact your Equipment Provider Become familiar with the product see Component Identification Position product near a properly grounded electrical receptacle Allow a minimum of 4 10 cm clearance on all sides to ensure adequate air flow for cooling of product Be sure the On Off I O Switch is in the Off O position Be sure the Power Cord is properly connected Attach appropriate device to the Outlet Fitting securely without overtightening Pull Regulator Knob OUT to unlock regulator then turn Knob fully counterclockwise Press the On Off I O Switch to the On I position Adjust pressure flow To INCREASE pressure flow Turn Knob CLOCKWISE To DECREASE pressure flow Turn Knob COUNTERCLOCKWISE Push Regulator Knob IN to lock pressure flow setting Compressor is now ready to use When the compressor is not in use press the On Off I O Switch to the OFF O position BEFORE STARTING UNIT Pull out regulator Knob to unlock then turn Knob fully counterclockwise EASY AIR 15 CLEANING MAINTENANCE AWARNING Disconnect product from any external power source before cleaning WEEKLY 1 Check both Air Filters on top rear of cabinet for dust buildup 2 If dust buildup occurs unplug product remove Air Filters from their recessed areas and wash in warm soapy water and rinse 3 Absorb excess water from filters with a dry towel 4 Return
9. ssnecsessucsseesseesssseesseeseesseesses 9 WARRANTY sssssessssssssessssssesscsssssssssssssssssssussussusssssassussucsussaseacesceseessssueseeasesscsssssuesseeneensens 10 DANGER indicat n imminently hazardous E Pea fac avoided i result in death or AWARNING ACAUTION CAUTION A 1 O serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Attention Consult ACCOMPANYING DOCUMENTS Type B Equipment Protective Earth Ground Power On Power Off EASY AIR 15 RECEIVING INSPECTION Remove product from package and inspect for damage If there is any damage do not use Contact your Equipment Provider INTENDED USE To supply breathable compressed air for respiratory care devices having performance requirements within the stated performance of the PM15F or PM15P see Specifications SPECIFICATIONS Operating Range PM15P Output PM15F Output 1 LPM Models Equiped with a Pressure Gage Models Equiped with a Flow Gage 5O PSis wis ireas minimum 15 LPM LPM as set and read on the gauge Maximum Rated Sustained Pressure 60 psi Dimensi
10. t is running e Close supervision is necessary when this product is used by on or near children or invalids e Use this product only for its Intended Use as described in this manual e DO NOT use attachments not recommended by the manufacturer e DO NOT use product with any equipment that requires dry air including ventilators gas blenders or flow generators without a device to properly dehumidify the discharged air of the PM15 e Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged if it has been dropped into water Return the product to your Equipment Provider for examination and repair e Keep the cord away from heated surfaces e Never use while sleepy or drowsy e Adjust to desired setting prior to use e Never drop or insert any object into any opening or hole e DO NOT cover air vents Restriction of air flow will cause unit to overheat causing the thermal reset to shut down the product e Connect this product to a properly grounded outlet only See Grounding Instructions EASY AIR 15 COMPONENT IDENTIFICATION Carry Handle On Off I O Switch Air Outlet Regulator Knob Air Inlet Filters Power Cord Power Cord Keeper Fuse Drawer AC Inlet Hour Meter EASY AIR 15 OPERATING INSTRUCTIONS Prior to each use Inspect product for damage DO NOT use if any damage is found 10 11 NOTE If fo
Download Pdf Manuals
Related Search
Related Contents
Manuel d`installation user manual - Alta Innovations Annexe - Rouen Xerox Guia do usuário pages 101 à 150 Bosch PSB 700-2 RE Eccotemp 45H-LP Instructions / Assembly Datei: steba_rk2, 306 kb Crimestopper Security Products EZ-31DP/33DP/34DP Remote Starter User Manual Trousse Happy Taq IVD Copyright © All rights reserved.