Home

Product Manual - ADEY Electronics

image

Contents

1. no mac address table G Remove anentry of switch config no filter hwaddr MAC address table mac address table filter hwaddr MAC filter 000012348678 no mac address table G Remove dynamic entry switch config no of MAC address table mac address table SNMP Commands Set Netstar Commands Level Description Example snmp system name System Name G Set SNMP agent system name switch config snmp system name I2switch snmp system location G Gei SNMP agent switch config snmp System Location system location system location lab snmp system contact G Gei SNMP agent switch config snmp System Contact system contact system contact where snmp agent mode G Select the agent mode switch config snmp agent mode v1v2c v3 v1v2cv3 of SNMP viv2cv3 snmp G Add SNMP community switch config snmp community strings string community strings public right Community rw right RO RW snmp server host G Configure SNMP switch config snmp server host IP address server host information 192 168 1 50 community public community and community string trap version v1 Community string remove trap version Switch config v1 v2c no snmp server host 192 168 1 50 snmpv3 context name G Configure the context switch config snmpv3 Context Name name context name Test snmpv3 user G Configure the switch config snmpv3 user User Name userprofil
2. Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com H RJ 45 Pin Assignments Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The following table shows the MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD ee Transmit Data minus TD Receive Data minus RD Switch Router or PC 3 TD 3 RD 6 TD gt 6 RD 1 RD em 1 TD 2 RD e A TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic 18 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 7924
3. Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 802 1x Radius System Configuration System Configuration Port Configuration Misc Configuration 802 1x Protocol Disable s Radius Server IP 0 0 0 0 Server Port fis 12 Accounting Port 1813 Shared Key 12345678 NAS Identifier NAS_L2_SWITCH Apply Help 802 1x System Configuration interface 802 1x Per Port Configuration You can configure the 802 1x authentication state for each port The state provides Disable Accept Reject and Authorize H Reject The specified port is required to be held in the unauthorized state H Accept The specified port is required to be held in the Authorized state H Authorized The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server H Disable When disabled the specified port works without complying with 802 1x protocol H Click Apply button Manual Documentation Number EIR618 2SFP T_0708m 111 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 802 1x Radius Port Configuration System Configuration Port Configuration Misc Con
4. www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com and responds only if it receives LACH protocol packets from the opposite device NOTE 1 A link having either two active LACP nodes or one active node can perform dynamic LACP trunk 2 A link having two passive LACP nodes will not perform dynamic LACP trunk because both ports are waiting for an LACP protocol packet from the opposite device Port Trunk State Activity Aggregator Setting Aggregator Information State Activity Port LACP State Activity Port LACP State Activity 1 M Active 2 M Active 3 M Active 4 M Active 5 N A 6 N A ri N A 8 N A 9 N A 10 N A 11 N A 12 N A 13 N A 14 N A 15 N A 16 N A 17 N A 18 N A Apply Help Port Trunk State Activity interface Port Mirroring The Port mirroring is a method for monitoring traffic in switched networks Traffic through ports can be monitored by one specific port which means traffic goes in or out monitored source ports will be duplicated into mirroring destination port 82 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Po
5. Fault Red Master Green 16 10 100TX Link Activity Green Full duplex Collision Yellow Gigabit Copper Link Activity Green Speed 1000M Green SFP Link Activity Green Manual Documentation Number EIR618 2SFP T_0708m e RRS MEIER SE 19 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable Network Cable EIA TIA 568 100 ohm 100m 1000Base T 2 pair UTP STP Cat 5e or 6 cable EIA TIA 568 100 ohm 100m m LC Multi mode 50 125um or 62 5 125um Optical cable m LC Single mode 9 125um Back plane 7 2Gbps Packet throughput 10 7Mpps at 64bytes ability 12 48 Voc Redundant power with polarity reverse protection and Power Supply removable terminal block The power supply should meet the document listed by UL and its output must comply with L P S Power i 11 2 Watts Consumption mm DIN Rail and Wall Mount Design 10 C to 60 C standard model Operation Temp 40 C to 75 C wide operating temperature model Operation 5 to 95 Non condensing Humidity Storage 40 C to 85 C Temperature i Dimensions 2 9 x 4 2 x 6 4 in 7 4 x 10 7 x 16 3 cm 120 Man
6. Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com from 4 Authentication Tick the checkbox to enable this function configuring the email account and password for authentication when Email Alert enabled this function will then be available 5 Mail Account Set up the email account e g johnadmin to receive the alert It must be an existing email account on the mail server which you had set up in SMTP Server IP Address column Password Type in the password to the email account 7 Confirm Password Reconfirm the password Rept e mail Address 1 6 You can also assign up to 6 e mail accounts to receive the alert 9 Click Apply button System Event Log SMTP Configuration Syslog Configuration SMTP Configuration Event Configuration E mail Alert Enable sl SMTP Server IP Address 192 168 16 5 Sender switchi01 123 com V Authentication Mail Account jiohnadmin Password Iesse Confirm Password ess Rcpt e mail Address 1 supervisor 123 com Rcpt e mail Address 2 FT Rcpt e mail Address 3 ee Rcpt e mail Address 4 SE Rcpt e mail Address 5 FT Rcpt e mail Address 6 es Het SMTP Configuration interface 68 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100
7. Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Event Log Event Configuration When the Syslog SMTP checkbox is marked the event log will be sent to system log server SMTP server Also per port log link up link down and both events can be sent to the system log server SMTP server with the respective checkbox ticked After configuring click Apply to have the setting taken effect m System event selection There are 4 event types Device cold start Device warm start Authentication Failure and X ring topology change Before you can tick the checkbox of each event type the Syslog Client Mode column on the Syslog Configuration tab E mail Alert column on the SMTP Configuration tab must be enabled first gt Device cold start When the device executes cold start action the system will issue a log event Device warm start When the device executes warm start the system will issue a log event Authentication Failure When the SNMP authentication fails the system will issue a log event X ring topology change When the X ring topology has changed the system will issue a log event H Port event selection Also before the drop down menu items are available the Syslog Client Mode column on the Syslog Configuration tab and the E mail Alert column on the SMTP Configuration
8. gt System Log Server Client gt SMTP e mail Alert gt Relay Alarm Output System Events Security gt Port Security MAC address entries filter gt IP Security IP address security management to prevent unauthorized intruder gt Login Security IEEE802 1X RADIUS SNMP Trap gt Device cold start Power status gt Authentication failure gt X Ring topology change gt Port Link up Link down IGMP with Query mode for Multi Media Application Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com m IFIP Firmware Update and System Configure Restore and Backup m Provides EFT protection 3 000 Voc for power line WR Supports 6 000 Vpc Ethernet ESD protection Software Specification SNMP v1 v2c and v3 management Web interface management Management Telnet interface management Command Line Interface CLI management RFC 1215 Trap RFC 1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RSTP MIB Private MIB Port based VLAN IEEE802 1Q Tag VLAN 256 entries VLAN ID up to 4k in number which can be assigned from 1 to 4096 VLAN GVRP 256 groups Double Tag VLAN Q in Q Private VLAN Port Trunk with LA
9. 2 x Forward Delay Time value 1 gt Max Age value gt 2 x Hello Time value 1 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com RSTP System Configuration System Configuration Port Configuration RSTP Mode Enable zl Priority 0 61440 32768 Max Age 6 40 Go Hello Time 1 10 E Forward Delay Time 4 30 fis Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 Apply Help Root Bridge Information Bridge ID 0080000F38013DAB Root Priority 32768 Root Port Root Root Path Cost 0 Max Age 20 Hello Time 2 Forward Delay 15 RSTP System Configuration interface RSTP Port Configuration You can configure path cost and priority of every port H Select the port in the port column field H Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200 000 000 H Priority Decide which port should be blocked by priority in LAN Enter a number 0 through 240 the port of the highest value will be blocked The value of priority must be the multiple of
10. Disable zl Port 12 Disable I Disable x Port 13 Disable x Disable zl Port 14 Disable z Disable zl Port 15 Disabe x Disable zl Port 16 Disable x Disabe H Port 17 Disable x Disable zl Port 18 Disable x Disable Apply Help Event Configuration interface Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Fault Relay Alarm Power Failure Tick the checkbox to enable the function of lighting up the FAULT LED on the panel when power fails Port Link Down Broken Tick the checkbox to enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken Fault Relay Alarm Power Failure M Power 1 M Power 2 Port Link Down Broken IT Poti VF Port2 IT Port3 VF Port4 l Pot5 VF Gore IT Port7 T Ports T Pot9 T Port 10 l Port 11 F Port 12 IT Port 13 F Port 14 IT Port 15 F Port 16 IT Port 17 I Port 18 Apply Fault Relay Alarm interface SNTP Configuration You can configure the SNTP Simple Network Time Protocol settings The SNTP allows you to synchronize switch clocks in the Internet 1 SNTP Client Enable disable SNTP function to get the time from the SNTP server Daylight Saving Tim
11. Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QOS GOnniquraion eelef 103 QoS Policy and Priority Type 103 Port based PHONY EE 104 COS Configuration EE 105 TOS Configura EE 105 E Ee el le Ee EE 106 KRINO EE 107 EEN eege 110 802 1X Radius CGontguraton rrenen 110 MAC Address Ke EEN 113 Factory DOU cates ces eticarastireodstnncicedetuaeutanies 116 Save CGontfguraton keen 116 System FCDOOL EE 117 Trouble SHOOTING cccceeeeeeesseeeeeeeeeeenees 118 Technical Specification ssccccceceees 119 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Introduction The 16 10 100TX 2 10 100 1000T Mini GBIC Combo w X Ring L2 Managed Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Features m System Interface Performance gt RJ 45 ports support Auto MDI MDI X Function SFP mini GBIC supports 100 1000 Dual Mode Store and Forward Switching Architecture Back plane Switching Fabric 7 2Gbps 1Mbits Packet Buffer 8K MAC Address
12. Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver Manual Documentation Number EIR618 2SFP T_0708m 21 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector from the transceiver and pull it out to release Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic part Pull out from the SFP module Wiring the Power Inputs 22 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb euro
13. Port 07 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 08 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 09 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 10 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 11 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 12 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 13 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 14 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 15 N A 100TX Up Enable Auto 100 Full 100 Full Enable ON OFF Port 16 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 17 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port 18 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port Control interface Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Trunk The Link Aggregation Control Protocol LACP provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs move the link to that Link Aggregation Group and
14. TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority WR Click Apply button to make the settings effective Manual Documentation Number EIR618 2SFP T_0708m 105 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com IGMP Configuration The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message shown as follows A message sent from the querier IGMP router or switch Query asking for a response from each host belonging to the multicast group A message sent by a host to the querier to indicate that the Report host wants to be or is a member of a given group indicated in the report message Leave A message sent by a host to the querier to indicate that the Group host has quit being a member of a specific multicast group The switch supports IP multicast You can enable IGMP protocol via setting the IGMP Config
15. otherwise the new configuration will lose when switch power off Manual Documentation Number EIR618 2SFP T_0708m 89 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 90 802 1Q VLAN Tagged based VLAN is an IEEE 802 1Q specification standard Therefore it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups to provide configuration Enable 802 1Q VLAN all ports on the switch belong to default VLAN of VID 1 The default VLAN can t be deleted GVRP GARP VLAN Registration Protocol is a protocol that facilitates control of virtual local area networks VLANs within a larger network GVRP conforms to the IEEE 802 1Q specification which defines a method of tagging frames with VLAN configuration data This allows network devices to dynamically exchange VLAN configuration information with other devices GVRP is based on GARP Generic Attribute Registration Protocol a protocol that defines procedures by which end stations and switches in a local a
16. 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from High to lowest queue For example while the system processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time in accordance with the 8 4 2 1 policy rule gt Use a strict priority scheme Always the higher queue will be processed first except the higher queue is empty gt Priority Type There are 5 priority type selections available Port based TOS only COS only TOS first and COS first Disable means no priority type is selected H Click Apply button to make the settings effective Manual Documentation Number EIR618 2SFP T_0708m 103 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS Configuration Qos Policy Use an 8 4 2 1 weighted fair queuing scheme Use a strict priority scheme Priority Type Disable 7 Apply Help Port based Priority Port 01 Port 02 Port 03 Port 04 Port 05 Port 06 Port 07 Port 08 Lowest x Lowest x Lowest z Lowest z Lowest z Lowest z Lowest x Lowest 7 Port 09 Port 10 Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 Lowest x Lowest x Lowes
17. 16 H Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a Manual Documentation Number EIR618 2SFP T_0708m 95 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 96 point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling H Admin Edge The port directly connected to end stations won t create bridging loop in the network To configure the port as an edge port set the port to True status H Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation H Click Apply Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 79
18. B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Security In this section you can configure the 802 1x and MAC address table 802 1X Radius Configuration 802 1x is an IEEE authentication specification which prevents the client from connecting to a wireless access point or wired switch until it provides authority like the user name and password that are verified by an authentication server such as RADIUS server System Configuration After enabling the IEEE 802 1X function you can configure the parameters of this function 110 IEEE 802 1x Protocol Enable or disable 802 1x protocol Radius Server IP Assign the RADIUS Server IP address Server Port Set the UDP destination port for authentication requests to the specified RADIUS Server Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS Server Shared Key Set an encryption key for using during authentication sessions with the specified RADIUS server This key must match the encryption key used on the RADIUS Server NAS Identifier Set the identifier for the RADIUS client Click Apply button Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park
19. Documentation Number EIR618 2SFP T_0708m 115 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com MAC Address Table All Mac Addresses Static MAC Addresses MAC Filtering All Mac Addresses Port No Port 01 D AABBCCDDEEFF STATIC Dynamic Address Count 0 Static Address Count 1 Clear MAC Table All MAC Address interface Factory Default Reset switch to default configuration Click Reset button to reset all configurations to the default value Factory Default M Keep current IP address setting M Keep current username amp password Reset Help Factory Default interface Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click Save to save the all configuration to the 116 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com flash memory Save Configuration Save Configuration interface System Reboot Reboot the switch in
20. Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com H Gateway Assign the network gateway for the industrial switch The default gateway is 192 168 16 254 DNS1 Assign the primary DNS IP address DNS2 Assign the secondary DNS IP address H And then click Apply IP Configuration DHCP Client Disable IP Address 192 168 16 1 Subnet Mask 255 255 255 0 Gateway 192 168 16 254 DNS1 0 0 0 0 DNS2 0 0 0 0 Apply Help IP configuration interface DHCP Server System configuration 62 DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for assigning dynamic IP addresses to devices on a network With dynamic addressing a device can have a different IP address every time it connects to the network In some systems the device s IP address can even change while it is still connected DHCP also supports a mix of static and dynamic IP addresses Dynamic addressing simplifies network administration because the software keeps track of IP addresses rather than requiring an administrator to manage the task This means that a new computer can be added to a network without the hassle of manually assigning it a unique IP address The system provides the DHCP server function Enable the DHCP server function the switch system will be a DHCP server H DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network H Lo
21. Radius Misc Configuration System Configuration Port Configuration Misc Configuration Quiet Period en Tx Period 30 Supplicant Timeout Bo Server Timeout 30 Max Requests 2 Reauth Period 3600 Apply Help 802 1x Misc Configuration interface MAC Address Table Use the MAC address table to ensure the port security Static MAC Address You can add a static MAC address it remains in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again You can add modify delete a static MAC address Add the Static MAC Address You can add static MAC address in the switch MAC table here m MAC Address Enter the MAC address of the port that should Manual Documentation Number EIR618 2SFP T_0708m 113 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com permanently forward traffic regardless of the device network activity H Port No Pull down the selection menu to select the port number H Click Add button H If you want to delete the MAC address from filtering table select the MAC address and click Delete b
22. Table Supports Wide Operating Temperature 40 C 75 C VK WW WW V H Case Installation gt IP 20 Protection gt DIN Rail and Wall Mount Design m Power Supply gt Wide Range Redundant Power Design gt Power Polarity Reverse Protect gt Overload Current Protection WR Spanning Tree gt Supports IEEE 802 1d Spanning Tree gt Supports IEEE 802 1w Rapid Spanning Tree m VLAN gt Port Based VLAN gt Support 802 1 Q Tag VLAN Manual Documentation Number EIR618 2SFP T_0708m 9 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com gt GVRP gt Double Tag VLAN Q in Q gt Private VLAN X Ring gt X Ring Dual Homing Couple Ring and Central Ring Topology gt Provide redundant backup feature and the recovery time below 20ms Port Trunk with LACP Support IEEE802 1ab LLDP QoS Quality of Service gt Support IEEE 802 1p Class of Service gt Per port provides 4 priority queues gt Port Base Tag Base and Type of Service Priority Bandwidth Control gt Ingress Packet Filter and Egress Rate Limit gt Broadcast Multicast Packet Filter Control Port Mirror Monitor traffic in switched networks gt TX Packet only gt RX Packet only gt Both of TX and RX Packet System Event Log
23. X Ring Group B mea Switch Industrial RI J Switch jJ Ke A i j Sa A He JI X Ring Backup Path Industrial Industrial Switch Switch Manual Documentation Number EIR618 2SFP T_0708m 31 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Console Management Connecting to the Console Port The supplied cable which one end is RS 232 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program To the console port of ToPC or Terminal the Industrial Switch DB 9 pin Female Pin Assignment DB9 Connector RJ 45 Connector 1 Orange White 2 Orange 3 Green White 4 Blue 5 Blue White 6 Green 7 Brown White 8 Brown 32 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com JI e GH ups Login in the Console Interface When th
24. beside the Enable Ring string label If this checkbox is not ticked all the ring functions are unavailable gt Enable Ring Master Tick the checkbox to enable this switch to be the ring master 1 amp 2 Ring Ports Pull down the selection menu to assign the ports as the member ports 17 Ring Port is the working port and 2 Ring Port is the backup port When 1 Ring Port fails the system will automatically upgrade the 2 Ring Port to be the working port m Enable Couple Ring To enable the coupe ring function tick the checkbox beside the Enable Couple Ring string label gt Couple Port Assign the member port which is connected to the other ring group Control Port When the Enable Couple Ring checkbox is ticked you have to assign the control port to form a couple ring group between the two X rings m Enable Dual Homing Set up one of the ports on the switch to be the Dual Homing port For a switch there is only one Dual Homing port Dual Homing function only works when the X Ring function enabled m Enable Central Ring x Tick the checkbox beside the string label of Enable Central Ring x to assign two ports as the blocking amp forwarding ports of the ring Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oran
25. connection occurs the backup port of the master switch Ring Master will automatically become a working port to recover from the failure The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If there are 2 or more switches in master Manual Documentation Number EIR618 2SFP T_0708m 107 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 108 mode the software will select the switch with lowest MAC address number as the ring master The X Ring master ring mode can be enabled by setting the X Ring configuration interface Also the user can identify whether the switch is the ring master by checking the R M LED indicator on the panel of the switch The system also supports the Couple Ring that can connect 2 or more X Ring group for the redundant backup function Dual Homing function that can prevent connection lose between X Ring group and upper level core switch Apart from the advantages Central Ring can handle up to 4 rings in the system and has the ability to recover from failure within 20 milliseconds m Enable Ring To enable the X Ring function tick the checkbox
26. enable Xring master G Enable ring master switch config Xring master Xring couplering G Enable couple ring switch config Xring couplering Xring dualhoming G Enable dual homing switch config Xring dualhoming Xring ringport G Configure 1st 2nd switch config Xring ringport 7 8 1st Ring Port 2nd Ring Port Ring Port Xring couplingport G Configure Coupling switch config Xring couplingport Coupling Port Port 1 Xring controlport G Configure Control Port switch config Xring controlport 2 Control Port Xring homingport G Configure Dual switch config Xring homingport Dual Homing Port Homing Port 3 show Xring P Show the information switch show Xring of X Ring no Xring G Disable X ring switch config no X ring no Xring master G Disable ring master switch config no Xring master no Xring couplering G Disable couple ring switch config no Xring couplering no Xring dualhoming G Disable dual homing switch config no Xring dualhoming 58 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Web Based Management This section introduces the configuration and functions of the Web Based management About
27. errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving good packets including undersize less than 64 bytes oversize CRC error fragments and jabbers via this port Tx Abort Packet The aborted packet while transmitting Packet Collision The counts of collision packet Packet Dropped The counts of dropped packet Rx Beast Packet The counts of broadcast packet Rx Mcast Packet The counts of multicast packet Click Clear button to clean all counts Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Statistics Tx Good Tx Bad Rx Good Rx Bad Tx Abort Packet Packet RX Bcast RX Mcast Port Type Link State Packet PacketPacket Packet Packet Collision Dropped Packet Packet Port OI 100TX Down Enable 0 0 0 0 0 0 0 0 0 Port 02 100TX Down Enable 0 D D 0 0 0 0 0 D Port 03 100TX Down Enable 0 0 0 0 0 0 0 0 0 Port 04 100TX Down Enable 0 0 D 0 0 D 0 0 D Port OS 100TX Down Enable 0 0 D 0 0 0 0 0 D Port O 100TX Down Enable 0 0 0 0 0 0 0 0 0 Port 07 100TX Down Enable 0 0 D 0 0 0 0 0 D Port 08 100TX Down Enable 0 0 D 0 0 0 0 0 D Port Oo 100TX Down Ena
28. frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast flooded uni cast bandwidth type broadcast multicast Set interface ingress limit frame type to accept broadcast and multicast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast bandwidth type broadcast only Set interface ingress limit frame type to only accept broadcast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast only bandwidth in Value Set interface input bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth in 100 bandwidth out Value Set interface output bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth out 100 show bandwidth Show interfaces bandwidth control switch config interface fastEthernet 2 switch config if show bandwidth 40 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmor
29. must equal the total number of group member ports Manual Documentation Number EIR618 2SFP T_0708m 79 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 5 Select the ports to join the trunk group The system allows four ports maximum to be aggregated in a trunk group Click Add button to add the port which is focused to the left field To remove unwanted ports select the port and click Remove button 6 When LACP enabled you can configure LACP Active Passive status for each port on State Activity page 7 Click Apply button 8 Use Delete button to delete Trunk Group Select the Group ID and click Delete button Port Trunk Aggregator Setting Aggregator Setting Aggregator Information State Activity System Priority GC Group ID Trunk 1 Di Select Lacp Eer Work Ports a lt lt Add Remove gt gt Apply Delete Help Notice The trunk function do not support GVRP and X Ring Port Trunk Aggregator Setting interface four ports are added to the left field with LACP enabled Aggregator Information When you have setup the aggregator setting with LACP disabled you will 80 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co In
30. nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP Manual Documentation Number EIR618 2SFP T_0708m 97 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 98 System Configuration Community Strings Here you can define the new community string set and remove the unwanted community string gt gt String Fill the name string RO Read only Enables requests accompanied by this community string to display MIB object information RW Read write Enables requests accompanied by this community string to display MIB object information and to set MIB objects Click Add button To remove the community string select the community string that you have defined and click Remove button You cannot edit the name of the default community string set H Agent Mode Select the SNMP version that you want to use and then click The Change button to switch to the selected SNMP version mode default value is SNMP v1
31. one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning NOTE Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 cable 7 When all connections are all set and LED lights all show in normal the installation is complete 28 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application The following figure is a sample application of the industrial switch 100Base TX Ethernet Cat3 5 UTP STP cable CH Data collect server Human Management Interface Enterprise Switch Industrial Switch Industrial Industrial Switch Switch Field Management 100Base TX Ethernet Progr
32. software reset Click Reboot to reboot the system System Reboot Please click Reboot button to restart switch device Reboot System Reboot interface Manual Documentation Number EIR618 2SFP T_0708m 117 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Trouble shooting 118 Verify that you are using the right power cord adapter DC 12 48V Please don t use the power adapter with DC output higher than 48V or this switch will be burned down Select the proper UTP STP cable to construct the user network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 cable for 10Mbps connections 100Q Category 5 cable for 100Mbps connections or 100 Q Category 5e above cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in you may have a problem with power cord
33. tab must be enabled first Those drop down menu items have 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event will be sent to the system log server SMTP server gt Link UP The system will issue a log message when port connection is up only Link Down The system will issue a log message when port connection is down only Link UP amp Link Down The system will issue a log message when port connection is up and down Manual Documentation Number EIR618 2SFP T_0708m 69 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 70 System Event Log Event Configuration Syslog Configuration SMTP Configuration J Event Configuration System event selection Event Type Syslog SMTP Device cold start O 0 Device warm start O O Authentication Failure E E X Ring topology change O O Port event selection Port Syslog SMTP Port 01 Disable zl Disable H Port 02 Disabe x Disabe zl Port 03 Disable I Disable x Port 04 Disable x Disable zl Port 05 Disable x Disable zl Port 06 Disable x Disable zl Port 07 Disabe x Disable zl Port 08 Disable x Disable zl Port 09 Disable x Disable zl Port 10 Disable x Disable zl Port 11 Disable H
34. the switch m Use the screws to screw on the DIN Rail on the industrial switch H To remove the DIN Rail reverse the step 1 Manual Documentation Number EIR618 2SFP T_0708m 25 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 First insert the top of DIN Rail into the track 2 of 3 Check the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse steps above Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the w
35. v2c only Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP System Configuration System Configuration Trap Configuration SNMPv3 Configuration I Community Strings Current Strings New Community String Remove Add public__RO String PString3 private RW PString1 CRO RW B tong RW ed Agent Mode Current Mode C SNMP V1 V2C only SNMP v1 v2c v3 deier SNMP V3 only GG SNMP V1 V2C V3 Change Help SNMP System Configuration interface Trap Configuration A trap manager is a management station that receives the trap messages generated by the switch If no trap manager is defined no traps will be issued Create a trap manager by entering the IP address of the station and a community string To define a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version IP Address Enter the IP address of the trap manager Community Enter the community string H Trap Version Select the SNMP trap version type v1 or v2c Click Add button m To remove the community string select the community string listed in the current managers field and click Remove bu
36. www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 6 Flow Control Set flow control function as Enable or Disable When enabled once the device exceed the input data rate of another device as a result the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time When disabled the receiving device will drop the packet if too much to process 7 Security Once the Security selection is set as On any access from the device which connects to this port will be blocked unless the MAC address of the device is included in the static MAC address table See the segment of Static MAC Table 8 Click Apply button to make the configuration effective Port Control Port State Negotiation Speed Duplex Flow Control Security Enable Auto Di 100 g Fui z Enable 7 off D Laeek ver Speed Duplex Flow Control Port Group ID Type Config Actual Config Actual Link State Negotiation Security 78 Port 01 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 02 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 03 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 04 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 05 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 06 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF
37. 00 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 88 VLAN Configuration VLAN Operation Mode Port Based zl l Enable GVRP Protocol Management Vlan ID fo Apply Group Name V_LAN1 VLAN ID fi Add Remove Gel Her VLAN Port Based Add interface m Enter the group name and VLAN ID Add the port number having selected into the right field to group these members to be a VLAN group or remove any of them listed in the right field from the VLAN RH Andthen click Apply button to have the settings taken effect m You will see the VLAN displays Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Configuration VLAN Operation Mode Port Based zl IT Enable GVRP Protocol Management Vlan ID fo Apply V_LAN1 1 Add Edit Delete Help VLAN Port Based Edit Delete interface m Lee Delete button to delete the VLAN m Use Edit button to modify group name VLAN ID or add remove the members of the existing VLAN group NOTE Remember to execute the Save Configuration action
38. 2444 Fax 353 91 792445 www bb europe com FCC This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures H Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver H Connect the equipment into an outlet on a circuit different from that to which the receiver is connected WR Consult the dealer or an experienced radio TV technician for help CE This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Manual Documentation Number EIR618 2SFP T_0708m 3 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb ele
39. 2445 www bb europe com RSTP Port Configuration System Configuration J Port Configuration Path Cost Priori 1 200000000 0 2 een Admin P2P Admin Edge Admin Non Stp 20000 128 Auto D true D false D Port 05 zl priority must be a multiple of 16 Apply Help RSTP Port Status Path Port OperOper Stp Port Cost Priority P2P Edge Neighbor tte Role Port 01 200000 128 True Tue False Disabled Disabled Port 02 200000 128 True Tue False Disabled Disabled Port 03200000 128 True Tue False Disabled Disabled Port 04200000 128 True Tue False Disabled Disabled Port 05200000 128 True Tue False Disabled Disabled Port 06 200000 128 True Tue False Disabled Disabled Port 07 200000 128 True Tue False Disabled Disabled Port 08 200000 128 True Tue False Disabled Disabled Port 09 200000 128 True Tue False Disabled Disabled Port 10 200000 128 True Tue False Disabled Disabled Port 11 200000 128 True Tue False Disabled Disabled Port 12200000 128 True Tue False Disabled Disabled Port 13 200000 128 True Tue False Disabled Disabled Port 14 200000 128 True Tue False Disabled Disabled Port 15 200000 128 True True False Forwarding Designated Port 16200000 128 True Tue False Disabled Disabled Port 17 20000 128 True Tue False Disabled Disabled Port 18 20000 128 True True False Disabled Disabled RSTP Port Configuration interface SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage
40. 45 www bb europe com H 2 Gigabit Copper SFP Mini GBIC combo port The Industrial switch has two auto detected Giga port UTP STP Fiber combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for the connection up to 1000Mbps The SFP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are for connecting to the network segment with single or multi mode fiber You can choose the appropriate mini GBIC module to plug into the slots You can use proper multi mode or single mode fiber according to the used SFP module With fiber optic it transmits speed up to 1000 Mbps and you can prevent noise interference from the system and transmission distance up to 110 km depending on the mini GBIC module The small form factor pluggable SFP is a compact optical transceiver used Im optical communications for both telecommunication and data communications applications Note The SFP Copper Combo port can be used at one time either The SFP port has the higher priority than copper port if you insert the 1000M SFP transceiver into the SFP port which is connected to the remote device the connection of the accompanying copper port will link down If you insert the 100M SFP transceiver into the SFP port even without a fiber connection to the remote the connection of the accompanying copper port will link down immediately Manual Documentation Number EIR618 2SFP T_0
41. 5 www bb europe com Top View The top panel of the 16 10 100TX 2 10 100 1000T Mini GBIC Combo wi X Ring L2 Managed Industrial Switch has one terminal block connector of two DC power inputs PWR2 Fault PWR1 Bere V1 V1 DC12 48V Top Panel of the industrial switch Manual Documentation Number EIR618 2SFP T_0708m 15 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides description of the LED status and their meanings for the System power on No power inputs The industrial switch is the master device of the switch X Ring group The industrial switch is not the master device of the X Ring group Power 1 is active Power 1 is inactive Power 2 is active Power 2 is inactive PWR1 PWR2 is inactive See alarm setting for operational details PWR1 amp PWR2 are both active or no power inputs Green Upper LED Connected to network Blinking Upper LED Networking is active Off Upper LED Not connected to network 16 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg C
42. 708m 19 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Cabling 20 Twisted pair segment can be established by using unshielded twisted pair UTP or shielded twisted pair STP cabling The cable between the link partner switch hub workstation etc and the converter must be less than 100 meters 328 ft long and comply with the IEEE 802 3ab 1000Base T standard for Category 5e or above Fiber segment using single mode connector type must use 9 125um single mode fiber cable You can connect two devices in the distance of 10 km Fiber segment using multi mode connector type must use 50 125 or 62 5 125um multi mode fiber cable You can connect two devices up to 550m distances The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communication applications To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Triangle Mark Transceiver to the SFP module Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350
43. 8m 65 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Restore Configuration interface TFTP Backup Configuration You can save the current configuration from flash ROM to TFTP server for restoring later 1 2 3 TFTP Server IP Address Type in the TFTP server IP Backup File Name Type in the file name Click Apply TFTP Backup Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 168 16 2 Backup File Name data bin Apply Help Backup Configuration interface System Event Log Syslog Configuration Configure the system event mode to collect system log 66 1 Syslog Client Mode Select the system log mode Client Only Server Only or Both System Log Server IP Address Assign the system log server IP When Syslog Client Mode is set as Client Only the system event log will only be sent to the client which has logged in on the switch When Syslog Client Mode is set as Server Only the system log will only be sent to the syslog server and you have to type the IP address in the Sysylog Server IP Address column If the Syslog Client Mode is set as Both the system log will be sent to client and server Click Reload
44. CP Port Trunk 4 Trunk groups Maximum 4 trunk LACP members Lee Supports LLDP that allows the switch to advertise its identity and capabilities on the LAN IEEE802 1d spanning tree Spanning tree IEEE802 1w rapid spanning tree Supports X Ring Dual Homing Couple Ring and Central X Ring e ing Manual Documentation Number EIR618 2SFP T_0708m 11 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Provides redundant backup feature and the recovery time below 20ms The quality of service determined by port Tag and IPv4 Quality of service Type of Service IPv4 IPv6 Different Service A Supports IEEE 802 1p class of service per port provides 4 Class of service E priority queues Supports 100 entries of MAC address for static MAC and Port Security another 100 for MAC filter TX packet only RX packet only Both of TX and RX packets Supports IGMP snooping v1 v2 and v3 Up to 256 multicast groups and IGMP query Supports 10 IP addresses that have permission to access IP Security the switch management and to prevent unauthorized intruder Login Security Supports IEEE 802 1X Authentication RADIUS Supports ingress packet filter and egress packet limit The egress rate control supports all of packet
45. Configure switch config smtp account account authentication account John smtp password G Configure switch config smtp password password authentication 1234 password smtp rcptemail G Configure Rept e mail switch config smtp reptemail 1 Index Email address Address Alert test com show smtp P Show the information switch show smtp of SMTP no smtp G Disable SMTP function switch config no smtp event device cold start G Setcoldstartevent switch config event Systemlog SMTP Both type device cold start both event G Gei Authentication switch config event authentication failure failure event type authentication failure both Systemlog SMTP Both event G Get X ring topology switch config event ring topology change changed event type ring topology change both Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 55 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Systemlog SMTP Both event systemlog Get port event for switch config interface Link UP Link Down Bot system log fastethernet 3 h switch config if event systemlog both event smtp Get port event for switch config interface Link UP Link Down Bot SMTP fastethe
46. LAN configure switch vlan database 42 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box Manual Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com mode Vianmode V To set switch VLAN switch vlan vlanmode portbase portbase 802 1q mode or gvrp switch vian vlanmode 802 1q or switch vian vlanmode gvrp no vian V No VLAN Switch vlan no vlan Ported based VLAN configuration vlan port based V Add new port based __ switch vlan vlan port based grpname VALN grpname test grpid 2 port 2 4 Group Name or grpid switch vlan vlan port based GroupID grpname test grpid 2 port 2 3 4 port PortNumbers show vlan GroupID V Show VLAN switch vlan show vlan 23 SH van information no vlan group V Delete port base group switch vian no vlan group 2 GroupID ID IEEE 802 1Q VLAN vlan 8021q name V Change the name of __ switch vlan vlan 8021q name e TESS VLAN group ifthe West vid 22 VID group didn t exist this command can t be applied vlan 8021q port V Assign a access link switch vlan vlan 8021q port 3 ae ae for VLAN by port if the access link untag 33 UntaggedVID port belong to a trunk group this command can t be applied vlan 8021q por
47. Product Description Model EIR618 2SFP T Documentation Number EIR618 2SFP T_0708m B B electronics MANUFACTURING COMPANY 707 Dayton Road PO Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B amp B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europe com Sales e mail sales bb europe com Technical Support e mail support bb europe com 2008 B amp B Electronics Mfg Co Inc Revised February 2008 Manual Documentation Number EIR618 2SFP T_0708m 1 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Eighteen Port Managed Industrial Ethernet Switches User Manual Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 79
48. Set period of daylight saving time if SNTP function is inactive this command can t be applied Parameter format yyyymmdd hh mm switch config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset G Gei offset of daylight switch config sntp Minute saving time if SNTP___ daylight offset 3 function is inactive this command can t be applied sntp ip G Gei SNTP server IP if switch config sntp ip 192 169 1 1 IP SNTP function is inactive this command can t be applied sntp timezone G Gei timezone index switch config sntp timezone 22 Timezone use show sntp timzezone command to get more information of index number show sntp P Show SNTP switch show sntp information show sntp timezone P Show index number of switch show sntp timezone time zone list no sntp G Disable SNTP function switch config no sntp no sntp daylight G Disable daylight saving switch config no sntp daylight time Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 57 X ring Commands Set Netstar Commands Level Description Example Xring enable G Enable X ring switch config Xring
49. Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance If the LED indicators are normal and the connected cables are correct but the packets still cannot be transmitted Please check the user system s Ethernet devices configuration or status Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Technical Specification The 16 10 100TX 2 10 100 1000T Mini GBIC Combo w X Ring L2 Managed Industrial Switch technical specification are as follows IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T IEEE 802 3z Gigabit fiber IEEE 802 3x Flow Control and Back pressure GE IEEE 802 3ad Port trunk with LACH IEEE 802 1d Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1p Class of Service IEEE 802 1Q VLAN Tag IEEE 802 1x User Authentication RADIUS IEEE 802 1ab LLDP 14 880 pps for 10Base T Ethernet port Transfer Rate 148 800 pps for 100Base TX FX Fast Ethernet port 1 488 000 pps for Gigabit Fiber Ethernet port MAC address 8K MAC address table Packet Buffer 1Mbits Per unit Power Green Power 1 Green Power 2 Green
50. Web based Management There is an embedded HTML web site residing in flash memory on CPU board of the switch which offers advanced management features and allows users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen Preparing for Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are listed as below m P Address 192 168 16 1 H Subnet Mask 255 255 255 0 H Default Gateway 192 168 16 254 m User Name root m Password root Manual Documentation Number EIR618 2SFP T_0708m 59 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Login 60 1 Launch the Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter File Edit View Favor
51. all mount plate reverse steps above J ite V i Screwing the wall mount plate on the Industrial media l I converter EE EE naan nn P Manual Documentation Number EIR618 2SFP T_0708m 27 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Installation In this paragraph it will describe how to install the 5 10 100TX with X Ring Web management industrial switch and the installation points for attention 1 Unpacked the Industrial switch 2 Check the DIN Rail is tightly screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation To wall mount the Industrial switch and then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Connect
52. ammable Cat3 5 UTP STP cable logic controller Serial Device Server Field Automatic device Field Automatic device Field Automatic device X Ring Application The industrial switch supports the X Ring protocol that can help the network system to recovery from network connection failure within 300ms or less and make the network system more reliable The X Ring algorithm is like as spanning tree protocol STP algorithm but it has faster recovery time than STP The following figure is a sample X Ring application Manual Documentation Number EIR618 2SFP T_0708m 29 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 100Base TX Ethernet Cat3 5 UTP STP cable Data collect server Human Management Interface LAN _ gees Rp een Enterprise Switch Industrial LJ Switch ZS j X Ring Field Management Backup E Se WS X Ring Group Industrial Switch 100Base TX Ethernet Cat3 5 UTP STP cable Programmable Distribute UO logic controller control system Serial Device Server ls 8 Field Automatic device Field Automatic device Field Automatic device Coupling Ring Application In the network it may have more than one X Ring gr
53. ber EIR618 2SFP T_0708m 35 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Enter the interface of fast Ethernet command Interface configuration with a specific interface while in global configuration mode Commands Set List To exit to global configuratio n mode switch config if privileged EXEC enter exit To exit to Use this mode to configure parameters for the switch and Ethernet ports mode enter exit or end User EXEC E Privileged EXEC P Global configuration G VLAN database V Interface configuration l System Commands Set Netstar Commands Level Description Example show config E Show switch switch gt show config configuration show terminal P Show console switch show terminal information write memory P Save user switch write memory configuration into permanent memory flash rom system name G Configure system switch config system name xxx System Name name system location G Gei switch system switch config system location System Location location string XXX system description G Gei switch system switch config system 36 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box Manua
54. ble 0 0 0 0 0 0 0 0 0 Port 10 100TX Down Enable 0 0 0 D 0 0 0 0 D Port 171 100TX DowneEnable 0 0 0 0 0 0 0 0 0 Port 12 100TX Down Enable 0 0 0 0 0 0 0 0 0 Port 13 100TX DownEnable D 0 0 0 0 0 0 0 0 Port 14 100TX Down Enable 0 0 0 D 0 0 0 0 D Port 18 100TX Up Enable 230 0 465 0 0 0 0 5 2 Port 16 100TX Down Enable D 0 D 0 0 0 0 0 D Port 17 1GTX mGBIC Down Enable 0 0 0 0 0 0 0 0 0 Port 18 1GTX mGBIC Down Enable 0 0 0 0 0 0 0 0 0 Clear Help Port Statistics interface Port Control In Port control you can view and set the operation mode of each port 1 Port Select the port that you want to configure 2 State Current port status The port can be set to disable or enable mode If the port state is set as Disable it will not receive or transmit any packet 3 Negotiation Auto and Force Being set as Auto the speed and duplex mode are negotiated automatically When you set it as Force you have to assign the speed and duplex mode manually 4 Speed It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only 5 Duplex It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only Manual Documentation Number EIR618 2SFP T_0708m 77 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104
55. c 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com see the local static trunk group information in here 1 Group Key Displays the trunk group ID 2 Port Member Displays the members of this static trunk group Group ID Trunk 1 D Select Lacp Disable DN Work Ports E lt lt Add Remove gt gt Port Trunk Aggregator Setting interface two ports are added to the left field with LACP disable Port Trunk Aggregator Information Aggregator Setting Aggregator Information State Activity Static Trunking Group Group Key 1 Port Member 78 Port Trunk Aggregator Information interface State Activity Having set up the LACP aggregator on the tab of Aggregator Setting you can configure the state activity for the members of the LACP trunk group You can tick or cancel the checkbox beside the state display When you remove the tick mark to the port and click Apply button the port state activity will change to Passive H Active The port automatically sends LACP protocol packets H Passive The port does not automatically send LACP protocol packets Manual Documentation Number EIR618 2SFP T_0708m 81 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104
56. c com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Content STEE Software Gpechhcaton errr nr nenen Package Content ccccccceceeeeeeeeeeeeeeeeeeeeeeeeneeeas Hardware Description scccccssssesseeeeseenees Physical Dimension W x D X H n sssssssssnnssnnnssannenns Pont ST EE MOD LEE LED INnGiC alors E EE Ell alo EE Wiring the Power Inputs ceeeeeeeeeeeeeeeeeeeeeees Wiring the Fault Alarm Contact Mounting Installation ccccsssesssseeeseeeeees DIN Rail Mounting NEE Wall Mount Plate Mounting ceeeeeeeeeeeeeeteee Hardware Installation cccccceeseeeeeeeeeeees Network Application csccccssssssssseesseneens et E ne Rei lee EE Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics oe Ge Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Elec Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Coupling Ring Application ccccceceeeeeeeeeeeees 30 Dual Homing Application cceeeeeeeeeeeeeeeeeeees 31 Console Management cccccccsseeseeeeeeeeeeeees 32 Connecting to the Console Port 32 PIN ASSIG MIME NN isi cade Rie aiken a aaah 32 Login in the Console Interface ss
57. ckup CGontguraton 66 System Event Log Syslog Configuration 66 System Event Log SMTP Configuration 67 System Event Log Event Configuration 69 Fault Relay eege ai 71 SNTP Configuration EE 71 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics oe Ge Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Elec Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com UE maren a 74 User Authentication cccceceseseeeeeeeeeeeseeeeeeeees 75 Porn E HOS EE 76 Pon Ett 77 Seel 79 Aggregator setting DEE 79 Aggregator Iniormaton AE 80 Ee E 81 Por MITON e beer mer rere a mene 82 Rate LING RE 84 VLAN COnfIQUIANION EE 86 VLAN configuration Port based VAN 86 802 TQ VLAN ccmictcotiencwsdadeah bende aa a oaa 90 Rapid Spanning Tree EE 94 RSTP System Configuration ccccceceeeeeeeeeeeeeeees 94 RSTP Porm ConniguraOnin geben 95 SNMP Configuration cccccscscsccececeeeceeeeseseseseees 97 System Configuration EE 98 TRAD COMMGUN ANON EE 99 SNMPV3 Configuration uk EEN 100 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway
58. d Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP SNMPv3 Configuration System Configuration Trap Configuration D SNMPv3 Configuration Context Table Context Name Apply User Table Current User Profiles New User Profile Remove Ada none UserID Authentication Password Privacy Password Group Table Current Group content New Group Table Remove Add Security Name User ID none Group Name OO Access Table Current Access Tables New Access Table Remove _Add none Context Prefix Group Name C NoAuthNoPriv AuthNoPriv C AuthPriv Context Match Rule Exact Prefix Read View Name Write View Name Notify View Name MIBView Table Current MIBTables New MIBView Table Remove Add none View Name Ir SubOid Tree Type Excluded Included Security Level Help Note Any modification of SNMPv3 tables might cause MIB accessing rejection Please take notice of the causality between the tables before you modify these tables SNMP V3 configuration interface Group Table Configure SNMP v3 group table Manual Documentation Number EIR618 2SFP T_0708m 101 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445
59. e Enable disable daylight saving time function When daylight saving time is enabled you need to configure the daylight saving time period UTC Timezone Set the switch location time zone The following table Manual Documentation Number EIR618 2SFP T_0708m 71 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am AST Atlantic Standard 4 hours 8 am EDT Eastern Daylight EST Eastern Standard 5 hours 7 am CDT Central Daylight CST Central Standard 6 hours 6 am MDT Mountain Daylight MST Mountain Standard 7 hours 5 am PDT Pacific Daylight PST Pacific Standard 8 hours 4am ADT Alaskan Daylight HAW Hawaiian 10 hours 2am Standard CET Central European FWT French Winter MET Middle European 1 hour 1 pm MEWT Middle European Winter SWT Swedish Winter EET Eastern European 2 hours 2pm USSR Zone 1 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commerc
60. e Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com state Enable Disable Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 config if state Disable show interface configuration show interface configuration status switch config interface fastEthernet 2 switch config if show interface configuration show interface status show interface actual status switch config interface fastEthernet 2 config if show interface status show interface accounting show interface statistic counter switch config interface fastEthernet 2 config if show interface accounting no accounting Clear interface accounting information switch config interface fastEthernet 2 switch config if no accounting Trunk Commands Set Netstar Commands Level Description Example aggregator priority 1 65535 G Set port group system priority switch config aggregator priority 22 aggregator activityport Group ID Port Numbers aggregator group GroupID Port list lacp Set activity port Assign a trunk group with LACP active GroupID 1 3 switch config aggregator activityport 2 switch config aggregator group 1 1 4 lacp work
61. e available to set the queuing policy for each port 104 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com H Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen m Click Apply button to make the settings effective COS Configuration Set up the COS priority level With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port WR COS priority Set up the COS priority level O 7 High Middle Low Lowest m Click Apply TOS Configuration Set up the TOS priority With the drop down selection item of Priority Type above being selected as TOS only TOS first this control item will then be available to set the queuing policy for each port m TOS priority The system provides 0 63 TOS priority level Each level has 4 types of priority High Middle Low and Lowest The default value is Lowest priority for each level When the IP packet is received the system will check the TOS level value in the IP packet that has received For example the user sets the TOS level 25 as high the system will check the
62. e connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None COM2 Properties 21x Port Settings Bits per second v Data bits eo M Parity None z Stop bits fo Flow control None sl Advanced Bestore Defaults The settings of communication parameters After finishing the parameter settings click OK button When the blank screen shows up press Enter key to bring out the login prompt Key in root default value for both User name and Password use Enter key to switch then press Enter key and the Main Menu of console management Manual Documentation Number EIR618 2SFP T_0708m 33 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com appears User Name Password Console login interface CLI Management The system supports the console management CLI command After you log in on to the system you will see a command prompt To enter CLI management interface type in enable command switch gt enable sw
63. e for test01 group G1 password Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 49 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com group Group Name password Authentication Password Privacy SNMPV3 agent Privacy password could be empty AuthPW PrivPW Password snmpv3 access G Configure the access _ switch config snmpv3 access context name Context table of SNMPV3 context name Test group G1 Name agent security level AuthPriv group match rule Exact views V1 V1 V1 Group Name security level NoAuthNoPriv AuthNoP riv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name snmpv3 mibview view G Configure the mibview switch config snmpv3 mibview View Name table of SNMPV3 view V1 type Excluded sub oid type agent 1 3 6 1 Excluded Included sub oid OID show snmp P Show SNMP switch show snmp configuration no snmp G Remove the specified switch config no snmp community strings community community strings public Community no snmp server host G Remove the SNMP switch config no snmp server Host address server host 192 168 1 50 no snmpv3 user G Remove specified user s
64. enable its transmission and reception functions in an orderly manner Link aggregation lets you group up to 4 ports into one dedicated connections This feature can expand bandwidth to a device on the network LACP operation requires full duplex mode more detail information refers to IEEE 802 3ad Aggregator setting 1 System Priority A value which is used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP 2 Group ID There are four trunk groups to be selected Choose the Group ID and click Select button 3 LACP When enabled the trunk group is using LACH A port which joins an LACP trunk group has to make an agreement with its member ports first When disabled the trunk group is a static trunk group The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports But member ports won t know that they should be aggregated together to form a logic trunk group 4 Work ports This column field allows the user to type in the total number of active port up to four With LACP static trunk group e g you assign four ports to be the members of a trunk group whose work ports column field is set as two the exceed ports are standby the LACP State Activity will show Passive on the tab of State Activity and can be aggregated if work ports fail If it is a static trunk group the number of work ports
65. erver lowip G Configure low IP switch config dhcpserver lowip Low IP address for IP pool 192 168 1 100 dhcpserver highip G Configure high IP switch config dhcpserver highip High IP address for IP pool 192 168 1 200 dhcpserver subnetmask G Configure subnet switch config dhcpserver Subnet mask mask for DHCP clients subnetmask 255 255 255 0 dhcpserver gateway G Configure gateway for switch config dhcpserver Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 37 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Gateway DHCP clients gateway 192 168 1 254 dhcpserver dnsip G Configure DNS IP for switch config dhcpserver dnsip DNS IP DHCP clients 192 168 1 1 dhcpserver leasetime G Configure lease time switch config dhcpserver Hours in hour leasetime 1 dhcpserver ipbinding Gei static IP for DHCP switch config interface IP address clients by port fastEthernet 2 switch config dhcpserver ipbinding 192 168 1 1 show dhcpserver P Show configuration of switch show dhcpserver configuration DHCP server configuration show dhepserver clients P Show client entries of switch show dhcpserver clients DHCP server show dhc
66. f monitor function show monitor RB Show port monitor switch show monitor Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 51 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com information show monitor Show port monitor information switch config interface fastEthernet 2 switch config if show monitor no monitor Disable source port of monitor function switch config interface fastEthernet 2 switch config if no monitor 802 1x Commands Set Netstar Commands Level Description Example 8021x enable G Use the 802 1x global switch config 8021x enable configuration command to enable 802 1x protocols 8021x system radiusip G Use the 802 1x system switch config 8021x system IP address radius IP global radiusip 192 168 1 1 configuration command to change the radius server IP 8021x system serverport G _ Use the 802 1x system switch config 8021x system port ID server port global serverport 1815 configuration command to change the radius server port 8021x system G Use the 802 1x system switch config 8021x system accountport account port global accountport 1816 port ID configuration command to change t
67. figuration State Authorize x Accept Authorize Hel Disable Port Authorization Port State Port OI Disable Port 02 Disable Port 03 Disable Port 04 Disable Port OS Disable Port 06 Disable Port 07 Disable Port 08 Disable Port 09 Disable Port 10 Disable Port 11 Disable Port 12 Disable Port 13 Disable Port 14 Disable Port 15 Disable Port 16 Disable Port 17 Disable Port 18 Disable 802 1x Per Port Setting interface Misc Configuration H Quiet Period Set the period which the port doesn t try to acquire a supplicant m TX Period Set the period the port waits for retransmit next EAPOL PDU during an authentication session H Supplicant Timeout Set the period of time the switch waits for a supplicant response to an EAP request m Server Timeout Set the period of time the switch waits for a server response to an authentication request H Max Requests Set the number of authentication that must time out before authentication fails and the authentication session ends 112 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com H Reauth period Set the period of time which clients connected must be re authenticated H Click Apply button 802 1x
68. g qos prioritytype port based cos only tos type only cos first tos first qos priority portbased G Configure Port based switch config qos priority fron Priority portbased 1 low lowest low middle high qos priority cos G Configure COS Priority switch config qos priority cos 0 A a mddi qos priority tos G Configure TOS Priority switch config qos priority tos 3 Priority lowest low mid nigh dle high show qos P Displays the Switch show qos information of QoS configuration no qos G Disable QoS function switch config no qos IGMP Commands Set Netstar Commands Level Description Example igmp enable G Enable IGMP switch config igmp enable Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 47 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com snooping function Igmp query auto G Ger IGMP query to switch config lgmp query auto auto mode Igmp query force G Ger IGMP query to switch config lgmp query force force mode show igmp P Displays the details of switch show igmp configuration configuration an IGMP configuration show igmp multi P Displays the details of switch show igmp multi an IGMP snooping entrie
69. he accounting port 8021x system sharekey G Use the 802 1x system switch config 8021x system ID 52 share key global configuration command to change the shared key value sharekey 123456 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 8021x system nasid words Use the 802 1x system nasid global configuration command to change the NAS ID switch config 8021x system nasid test1 8021x misc quietperiod sec Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch switch config 8021x misc quietperiod 10 8021x misc txperiod Use the 802 1x misc switch config 8021x misc sec TX period global txperiod 5 configuration command to set the TX period 8021x misc Use the 802 1x misc switch config 8021x misc supportimeout sec 8021x misc servertimeout sec supp timeout global configuration command to set the supplicant timeout Use the 802 1x misc server timeout global configuration command to set the server timeout supportimeout 20 switch config 8021x misc servertimeout 20 8021x misc maxreq
70. ial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com BT Baghdad USSR 3 hours Zone 2 WAST West Australian 7 hours Standard CCT China Coast 8 hours USSR Zone 7 JST Japan Standard 9 hours USSR Zone 8 EAST East Australian Standard GST Guam Standard USSR Zone 9 10 hours IDLE International Date Line NZST New Zealand 12 hours Midnight Standard NZT New Zealand 4 SNTP Sever URL Set the SNTP server IP address Switch Timer Displays the current time of the switch Daylight Saving Period Set up the Daylight Saving beginning time and Daylight Saving ending time Both will be different in every year 7 Daylight Saving Offset mins For non US and European countries specify the amount of time for day light savings 8 Click Apply Manual Documentation Number EIR618 2SFP T_0708m 73 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNTP Configuration SNTP Client Enable e Daylight Saving Time Enable UTC Timezone GMT 08 00 Taipei SNTP Server URL 76 168 30 201 Switch Timer Daylight Saving Period 20040101 00 0 20040101 00 0 Daylight Saving Offset mins 0 Geet SNTP Configuration i
71. iguration Port based VLAN Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored In order for an end station to send packets to different VLAN groups it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com other information about the packet such as the protocol VLAN Configuration VLAN Operation Mode Port Based zl IT Enable GVRP Protocol Management Vlan ID fo Add Edit Delete Help VLAN Port Based interface m Pull down the selection item and focus on Port Based then press Apply button to set the VLAN Operation Mode in Port Based mode m Click Add button to add a new VLAN group The maximum VLAN group is up to 64 VLAN groups Manual Documentation Number EIR618 2SFP T_0708m 87 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 51
72. ing Tree 94 The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol RSTP System Configuration m The user can view spanning tree information of Root Bridge m The user can modify RSTP state After modification click Apply button gt NOTE RSTP mode The user must enable the RSTP function first before configuring the related parameters Priority 0 61440 The switch with the lowest value has the highest priority and is selected as the root If the value is changed the user must reboot the switch The value must be a multiple of 4096 according to the protocol standard rule Max Age 6 40 The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The time that controls the switch to send out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 The number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Follow the rule as below to configure the MAX Age Hello Time and Forward Delay Time
73. itch _ CLI command interface The following table lists the CLI commands and description 34 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Commande Level Access Prompt About This Mode Method The user commands available at the user level are a subset of Begin a Enter those available at the User EXEC session with switch gt logout or privileged level your switch quit Use this mode to e Perform basic tests e Display system information The privileged Enter the command is the enable Enter advanced mode Privileged EXEC command switch disable to Use this mode to while in User exit e Display advanced EXEC mode function status e Save configuration Enter the To exit to Use this mode to configure _ privileged configure those Global command switch EXEC parameters that are Configuration while in config ee mode enter going to be applied to privilege EXEC mode Enter the vlan exit or end your switch database To exit to Use this mode to VLAN command switch user EXEC configure database while in vlan mode enter VLAN specific privileged exit parameters EXEC mode Manual Documentation Num
74. ites Tools Help Q Back gt 7 x E A e Search ST Favorites 4 s e Address Lei http 192 168 16 1 3 The login screen will appear right after Key in the user name and password The default user name and password are the same as root 5 Press Enter or click OK button and then the home screen of the Web based management appears Connect to 192 168 16 1 index htm User name fs root D Password cece T Remember my password on Note The web interface features shown below are introduced by the screen displays of 16 10 100 TX 2 10 100 1000T Mini GBIC Combo model Unless specifically identified the all of the screen displays are suitable for the models in this manual Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Information Assign the system name and location and view the system information System Name Assign the system name of the switch The maximum length is 64 bytes System Description Describes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Dis
75. k Access Link Access Link Access Link Access Link Access Link Access Link Access Link Access Link BR RRB RB RRB RRR RR Re WW wo 802 1Q VLAN interface Group Configuration Edit the existing VLAN Group H Select the VLAN group in the table list WR Click Edit button Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Configuration VLAN Operation Mode 802 19 sl IT Enable GVRP Protocol Management Vlan ID Jo Apply 802 1Q Configuration Delete Group Configuration interface m You can modify the VLAN group name and VLAN ID VLAN Configuration VLAN Operation Mode 802 10 d l Enable GVRP Protocol Management Vlan ID lo Apply 802 1Q Configuration J Group Configuration Group Name VLAN_3 VLAN ID 3 Apply Group Configuration interface H Click Apply button Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 93 Rapid Spann
76. l Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Description description string description xxx system contact G Get switch system switch config system contact System Contact contact window string xxx show system info E Show system switch gt show system info information ip address G Configure the IP switch config ip address lp address address of switch 192 168 1 1 255 255 255 0 Subnet mask 192 168 1 254 Gateway ip dhcp G Enable DHCP client switch config ip dhcp function of switch show ip P Show IP information of switch show ip switch no ip dhcp G Disable DHCP client switch config no ip dhcp function of switch reload G de performacold _ switch config reload default G Restore to default switch config default admin username G Changes a login switch config admin username Username username XXXXXX maximum 10 words admin password G Specifies a password switch config admin password Password maximum 10 words XXXXXX show admin P Show administrator switch show admin information dhcpserver enable G Enable DHCP Server switch config dhcpserver enable Dhcpserver disable G Disable DHCP Server switch config no dhcpserver dhcps
77. more Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com gt 1 Ring Port Assign a port which is used to be the forwarding port to the ring gt 2 Ring Port Assign a port which is used to be the blocking port to the ring m And then click Apply button to apply the configuration X Ring Configuration Ehe Master 1st Ring Port Port 01 D LINKDOWN 2nd Ring Port Port 02 D LINKDOWN l Enable Couple Ring Couple Port Port 03 sl LINKDOWN Control Port Port 04 D LINKDOWN I Enable Dual Homing Homing Port Port 05 D LINKDOWN IT Enable Central Ring 1 1st Ring Port Port 09 D LINKDOWN 2nd Ring Port Port 10 D LINKDOWN IT Enable Central Ring 2 1st Ring Port Port 11 D LINKDOWN 2nd Ring Port Port 12 sl LINKDOWN IT Enable Central Ring 3 1st Ring Port Port 13 D LINKDOWN 2nd Ring Port Port 14 D LINKDOWN IT Enable Central Ring 4 1st Ring Port Port 15 D LINKDOWN 2nd Ring Port Port 16 D FORWARDING Help X ring Interface NOTE 1 When the X Ring function enabled the user must disable the RSTP The X Ring function and RSTP function cannot exist on a switch at the same time 2 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch powers off Manual Documentation Number EIR618 2SFP T_0708m 109 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com
78. nd IP Binding Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com TFTP Update Firmware It provides the functions that allow user to update the switch firmware Before updating make sure the TFTP server is ready and the firmware image is located on the TFTP server 1 TFTP Server IP Address Type in your TFTP server IP 2 Firmware File Name Type in the name of firmware image 3 Click Apply TFTP Update Firmware Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 168 16 2 Firmware File Name fimage bin Apply Help Update Firmware interface TFTP Restore Configuration You can restore the configuration from TFTP server Before doing that you must put the image file on TFTP server first and the switch will download back the flash image 1 TFTP Server IP Address Type in the TFTP server IP 2 Restore File Name Type in the correct file name for restoring 3 Click Apply TFTP Restore Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 168 16 2 Restore File Name data bin Apply Help Manual Documentation Number EIR618 2SFP T_070
79. nds Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs switch config spanning tree hello time 3 spanning tree forward time seconds Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening switch config spanning tree forward time 20 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 45 stp path cost l 1 200000000 and learning states last before the port begins forwarding Use the spanning tree cost interface configuration command to set the path cost for Spanning Tree Protocol STP calculations In the event of a loop spanning tree considers the path cost when selecting an interface to place into the forwarding state switch config interface fastEthernet 2 switch config if stp path cost 20 stp path priority l Port Priority Use the spanning tree port priority interface configuration command to configure a port priority that is used when two s
80. nterface IP Security IP security function allows the user to assign 10 specific IP addresses that have permission to access the switch through the web browser for the securing switch management H IP Security Mode When this option is in Enable mode the Enable HTTP Server and Enable Telnet Server checkboxes will then be available m Enable HTTP Server When this checkbox is ticked the IP addresses among Security IP1 IP10 will be allowed to access this switch via HTTP service H Enable Telnet Server When this checkbox is ticked the IP addresses among Security IP1 IP10 will be allowed to access this switch via telnet service H Security IP 1 10 The system allows the user to assign up to 10 specific IP addresses for access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet service m And then click Apply button to apply the configuration NOTE Save the configuration 74 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com IP Security IP Security Mode Disable D IT Enable HTTP Server l Enable Telnet Server Security IP1 Security IP2 Security IP3 Security IP4 Security IP5 Security IP6 Securit
81. o Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Yellow Ethernet port full duplex Lower LED Pinging Collision of packets occurs Lower LED P Off Ethernet port half duplex or not connected to Lower LED network Green Upper LED Connected to network Blinking Networking is active Upper LED P17 P18 Off 10 100 1000T Upper LED Not connected to network Green The port is operating at soeed of 1000M Lower LED 8 d S P Off The port is disconnected or operates at speed Lower LED of 10 100M P17 P18 SFP port is connected to network Link Active Blinking Networking is active 1901090 SPR Not connected to network Ports E RJ 45 ports The UTP STP ports will auto sense for 10Base T 100Base TX connections Fast Ethernet or 10Base T 100Base TX or 1000Base T connections Gigabit Ethernet Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schematic Manual Documentation Number EIR618 2SFP T_0708m 17 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics
82. oesnnoan00aaaaaaan 33 CLI a Le Gun E E 34 Commands Level EEN 35 Commands Set List E 36 System Commands Get 36 Port Commands EE 39 Trunk Commands Set AEN 41 VLAN elle Le E 42 Spanning Tree Commands Gei 44 QOS Commands E 47 IGMP COMMANnGS SCli d s scicrtedeuadeeddeodsyatetierdeasnceededeadecnteds 47 Mac Filter Table Commands Get 48 SNMP Gommands Eege ees ue toast 49 Port Mirroring Commands Get 51 802 1x Commands Sel sccssr ceca dv caches cea 52 TFTP Commands Get EEN 54 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SystemLog SMTP and Event Commands Set 55 SNTP Commands SO bs coi acc cute aisec da gastodddedeateadieansavossecisees 56 X ring Commands Selcax ciaw ou teveermercescecdeeeeeecneneates 58 Web Based Management ccccccceceen 59 About Web based Management 59 Preparing for Web Management 59 Systemi LOGI DEE 60 System IMOKMANOM WE 61 IP COMMQUINATION DE 61 DHCP Server System configuration 62 DHCP Server Client Entries AA 63 DHCP Server Port and IP Bindings sssaaannan 64 TFTP Update Emmmware AAA 65 TFTP Restore Configuration sscssccceeees 65 TFTP Ba
83. or system quick upload and installation download Package Contents Please refer to the package content list below to verify them against the checklist m One EIR618 2SFPT Industrial Switch One Quick Start Guide H One CD ROM containing a user manual RH Two mounting plates with six screws m One RJ 45 to DB9 Female cable If any item is missing contact B amp B Electronics for a replacement Manual Documentation Number EIR618 2SFP T_0708m 13 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Description In this paragraph we will describe the Industrial switch s hardware spec port cabling information and wiring installation Physical Dimension W x D x H 2 9 x 4 2 x 6 4 in 7 4 x 10 7 x 16 3 cm Front Panel The front panel of the 16 10 100TX 2 10 100 1000T Mini GBIC Combo w X Ring L2 Managed Industrial Switch is shown as below Front Panel of the industrial switch 14 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 79244
84. ort 1 as 1Mbps ingress rate 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate gt Ingress Enter the port effective ingress rate The default value is 0 gt Egress Enter the port effective egress rate The default value is 0 And then click Apply to make the settings taken effect Manual Documentation Number EIR618 2SFP T_0708m 85 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN configuration 86 A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable VLAN Configuration VLAN Operation Mode Disable gt IT Enable GVRP Protocol Management Vlan ID fo Apply VLAN NOT ENABLE VLAN Configuration interface VLAN conf
85. ortNumber GI hybrid link untag VLAN by trunk group hybrid link untag 4 tag 3 6 8 UntaggedVID or tag TaggedVID List switch vlan vlan 8021q trunk 3 hybrid link untag 5 tag 6 8 show vlan GroupID V Show VLAN switch vlan show vlan 23 ee information show vlan no vlan group V Delete port base group switch vian no vlan group 2 GroupID ID Spanning Tree Commands Set seconds 44 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box max age global configuration Netstar Commands Level Description Example spanning tree enable G Enable spanning tree switch config spanning tree enable spanning tree priority G Configure spanning switch config spanning tree 0 61440 tree priority parameter priority 32767 spanning tree max age G Use the spanning tree switch config spanning tree max age 15 Manual Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com command to change the interval between messages the spanning tree receives from the root switch If a switch does not receive a bridge protocol data unit BPDU message from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology spanning tree hello time seco
86. oup By using the coupling ring function can connect each X Ring for the redundant backup It can ensure the transmissions between two ring groups will no failure The following figure is a sample of coupling ring application Coupling Ring Backup Path Backup path RH Te a Coupling Ring Group X Ring Group A Backup path 30 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Dual Homing Application Dual Homing function is to prevent the connection lose between X Ring group and upper level core switch Assign two ports to be the Dual Homing port that is backup port in the X Ring group The Dual Homing function only work when the X Ring function is active Each X Ring group only has one Dual Homing port NOTE In Dual Homing application architecture the upper level switches need to enable the Rapid Spanning Tree protocol Ethernet Switch Rapid Spanning Tree Protocol Ethernet Switch CH l aerer meree Gap eg Hot Standby Link i 4 X Bo Industrial DCH Path i Pe La Industrial Switch Nee Dual Homing i backup port oe F X Ring Group A industrial
87. p 2 or Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 41 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com workp Workport Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 2 1 4 3 lacp workp 3 aggregator group G Assign a static trunk switch config aggregator group GroupID Port list group 1 2 4 nolacp nolacp GroupID 1 3 or Port list Member port switch config aggregator group list This parameter 1 3 1 2 nolacp could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 show aggregator P Show the information switch show aggregator 1 of trunk group or switch show aggregator 2 or switch show aggregator 3 no aggregator lacp G Disable the LACP switch config no aggreator lacp GroupID function of trunk group 1 no aggregator group G Remove a trunk group switch config no aggreator GroupID group 2 VLAN Commands Set Netstar Commands Level Description Example vlan database P Enter V
88. pe com Please follow the steps below to insert the power wire V V V V 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Wiring the Fault Alarm Contact Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com NOTE Use 12 to 24 AWG wire NOTE Relay contacts are normally closed NOTE The Relay Alarm also requires software configuration Refer to the Web Based Management Fault Relay Alarm Section 24 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Rear Panel of
89. plays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer default And than click Apply button IP Configuration User can configure the IP Settings and DHCP client function in here DHCP Client Enable or disable the DHCP client function When DHCP client function is enabled the industrial switch will be assigned an IP address from the network DHCP server The default IP address will be replaced by the assigned IP address on DHCP server After user click Apply button a popup dialog shows up It is to inform the user that when the DHCP client is enabled the current IP will lose and user should find the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabled and then the user doesn t need to assign the IP address And the network DHCP server will assign the IP address displaying in this column for the industrial switch The default IP is 192 168 16 1 Subnet Mask Assign the subnet mask to the IP address If DHCP client function is enabled and then the user does not need to assign the subnet mask Manual Documentation Number EIR618 2SFP T_0708m 61 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway
90. pserver P Show IP Binding switch show dhcpserver ip binding information of DHCP lip binding server no dhcpserver G Disable DHCP server switch config no dhcpserver function security enable G Enable IP security switch config security enable function security http G Enable IP security of switch config security http HTTP server security telnet G Enable IP security of switch config security telnet telnet server security ip G Gei the IP security list switch config security ip 1 Index 1 10 IP 192 168 1 55 Address show security D Show the information switch show security of IP security no security G Disable IP security switch config no security function no security http G Disable IP security of switch config no security http HTTP server no security telnet G Disable IP security of switch config no security telnet 38 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com telnet server Port Commands Set Netstar Commands Level Description Example interface fastEthernet G Choose the port for switch config interface Portid modification fastEthernet 2 duplex Use the duplex switch config in
91. rea network LAN can register and de register attributes such as identifiers or addresses with each other Every end station and switch thus has a current record of all the other end stations and switches that can be reached GVRP like GARP eliminates unnecessary network traffic by preventing attempts to transmit information to unregistered users In addition it is necessary to manually configure only one switch and all the other switches will be configured accordingly Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 802 1Q Configuration m Pull down the selection item and focus on 802 1Q then press Apply button to set the VLAN Operation Mode in 802 1Q mode m Enable GVRP Protocol Tick the checkbox to enable GVRP protocol This checkbox is available while the VLAN Operation Mode is in 802 1Q mode Select the port you want to configure Link Type There are 3 types of link type gt Access Link Single switch only it allows the user to group ports by assigning the same Untagged VID While this link type is set the Untagged VID column field is available but the Tagged VID column field is disabled gt Trunk Link The extended application of Acce
92. rnet 3 h switch config if event smtp both show event P Show event selection jswitch show event no event Disable cold start switch config no event device cold start event type device cold start no event G Disable Authentication switch config no event authentication failure failure event typ authentication failure no event G Disable X ring switch config no event X ring topology change topology changed X ring topology change event type no event systemlog Disable port event for jswitch config interface system log fastethernet 3 switch config if no event systemlog no event smpt Disable port event for jswitch config interface SMTP fastethernet 3 switch config if no event smtp show systemlog P Show system log client switch show systemlog amp server information SNTP Commands Set Netstar Commands Level Description Example sntp enable G Enable SNTP function switch config sntp enable sntp daylight G Enable daylight saving switch config sntp daylight time if SNTP function is inactive this command can t be applied 56 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box Manual Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com sntp daylight period Start time End time
93. rt Mirroring Destination Port Source Port RX TX RX TX Port 01 fe fe O E Port 02 C E IT Port 03 C E E Port 04 C C E E Port 05 C C O E Port 06 C E E Port 07 C O E Port 08 C C Port 09 C C IT C Port 10 C C E IT Port 11 Cc IT C Port 12 C E E Port 13 C C E E Port 14 C O C Port 15 C E O Port 16 Cc E IT Port 17 C E E Port 18 C O E Apply Help Port Trunk Port Mirroring interface Destination Port There is only one port can be selected to be the destination mirroring port for monitoring both RX and TX traffic which come from the source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only The user can connect the mirroring port to LAN analyzer or Netxray Source Port The ports that the user wants to monitor All monitored port traffic will be copied to mirroring destination port The user can select multiple source ports by ticking the RX or TX checkboxes to be monitored And then click Apply button Manual Documentation Number EIR618 2SFP T_0708m 83 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Rate Limiting You can set up every port s frame limitation type and bandwidth rate Rate Limi
94. s no igmp G Disable IGMP switch config no igmp snooping function no igmp query G Disable IGMP query _ switch no igmp query Mac Filter Table Commands Set Netstar Commands Level Description Example mac address table static hwaddr MAC Configure MAC address table of interface static switch config interface fastEthernet 2 switch config if mac address tab le static hwaddr 000012345678 mac address table filter G Configure MAC switch config mac address table hwaddr address table filter filter hwaddr 000012348678 MAC show mac address table P Show all MAC address switch show mac address table table show mac address table P Show static MAC switch show mac address table static address table static show mac address table P Show filter MAC switch show mac address table filter address table filter no mac address table static hwaddr MAC Remove an entry of MAC address table of interface static switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 48 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 000012345678
95. se Time sec 86400 Apply Help DHCP Server Configuration interface DHCP Server Client Entries When the DHCP server function is active the system will collect the DHCP client information and displays it at this tab Manual Documentation Number EIR618 2SFP T_0708m 63 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com DHCP Server Client Entries System Configuration J Client Entries Port and IP Binding IP addr Client ID Type Status Lease DHCP Client Entries interface DHCP Server Port and IP Bindings Assign the dynamic IP address to the port When the device is connecting to 64 the port and asks for IP assigning the system will assign the IP address that has been assigned before to the connected device DHCP Server Port and IP Binding System Configuration Client Entries Port IP Port 01 0 0 0 0 Port 02 0 0 0 0 Port 03 0 0 0 0 Port 04 0 0 0 0 Port 05 0 0 0 0 Port 06 0 0 0 0 Port 07 0 0 0 0 Port 08 0 0 0 0 Port 09 0 0 0 0 Port 10 0 0 0 0 Port 11 0 0 0 0 Port 12 0 0 0 0 Port 13 0 0 0 0 Port 14 0 0 0 0 Port 15 0 0 0 0 Port 16 0 0 0 0 Port 17 0 0 0 0 Port 18 0 0 0 0 Apply Help Port and IP Bindings interface J Port a
96. server and need to flash restore_cfg specify the IP of TFTP server and the file name of image upgrade G Upgrade firmware by switch config upgrade flash upgrade_fw TFTP and need to specify the IP of TFTP server and the file name of image lash upgrade_fw 54 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SystemLog SMTP and Event Commands Get Netstar Commands Level Description Example systemlog ip IP address G Set System log server IP address switch config systemlog ip 192 168 1 100 systemlog mode G Specified the log mode switch config systemlog mode client server both both show systemlog E Displays system log Switch gt show systemlog show systemlog Show system log client switch show systemlog amp server information no systemlog G Disable systemlog switch config no systemlog functon smtp enable G Enable SMTP function switch config smtp enable smtp serverip G Configure SMTP switch config smtp serverip IP address server IP 192 168 1 5 smtp authentication G Enable SMTP switch config smtp authentication authentication smtp account G
97. ss Link It allows the user to group ports by assigning the same Tagged VID across 2 or more switches Having set this link type the Tagged VID column field is available but the Untagged VID column field is disabled gt Hybrid Link Both Access Link and Trunk Link are available Untagged VID Assign the untagged frame VID H Tagged VID Assign the tagged frame VID H Click Apply button to have the settings taken effect m Youcan see the link type untagged VID and tagged VID information of each port in the table below on the screen Manual Documentation Number EIR618 2SFP T_0708m 91 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 92 Port O1 Port 02 Port 03 Port 04 Port OS Port Oe Port 07 Port 08 Port 09 Port 10 Port 11 Port 3 Port 3 Port 14 Port 15 Port 16 Port 17 Port 18 VLAN Configuration VLAN Operation Mode 802 10 d IT Enable GVRP Protocol Management Vlan ID Jo Apply 802 1Q Configuration Group Configuration Port Link Type Untagged Vid Tagged Vid Port 01 7 Access Link x fi _Apply _Help Link Type Untagged Vid Tagged Vid Access Link Access Link Access Link Access Link Trunk Link Trunk Link Access Link Access Link Access Link Access Lin
98. t V Assign a trunk link for switch vlan vlan 8021q port 3 PortNumber trunk link tag TaggedVID List VLAN by port if the port belong to a trunk trunk link tag 2 3 6 99 or Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 43 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com group this command _ switch vian vlan 8021q port 3 can t be applied trunk link tag 3 20 vlan 8021q port V Assign a hybrid link for switch vlan vlan 8021q port 3 PortNumber er hybrid link untag VLAN by port ifthe hybrid link untag 4 tag 3 6 8 UntaggedVID port belong to a trunk jor tag Tagged VID List group this command _ switch vlan vlan 8021q port 3 can t be applied hybrid link untag 5 tag 6 8 vlan 8021q trunk V Assign a access link switch vlan vlan 8021q trunk 3 PortNumber 4 access link untag for VLAN by trunk access link untag 33 UntaggedVID group vlan 8021q trunk V Assign a trunk link for switch vlan vlan 8021q trunk 3 PortNumber li trunk link tag VLAN by trunk group Itrunk link tag 2 3 6 99 TaggedVID List S switch vlan vlan 8021q trunk 3 trunk link tag 3 20 vlan 8021q trunk V Assign a hybrid link for switch vlan vlan 8021q trunk 3 P
99. t z Lowest z Lowest z Lowest z Lowest x Lowest 7 Port 17 Port 18 Lowest sl Lowest x Apply Help cos Priority 0 1 2 3 4 5 6 7 Lowest zl Lowest z Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Apply _Help TOS Priority 0 1 2 3 4 3 6 7 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 8 9 10 11 12 13 14 15 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 16 17 18 19 20 21 22 23 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 24 25 26 27 28 29 30 31 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 32 as 34 33 36 37 38 39 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 40 41 42 43 44 45 46 47 Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 48 49 50 51 52 oo 54 See Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest zl Lowest z Priority 56 RVs 58 59 6 0 61 62 63 Lowest z Lowest z Lowest z Lowest x Lowest z Lowest z Lowest z Lowest sl Apply Help QoS Configuration interface Port based Priority Configure the priority level for each port With the drop down selection item of Priority Type above being selected as Port based this control item will then b
100. terface full half configuration fastEthernet 2 command to specify switch config if duplex full the duplex mode of operation for Fast Ethernet speed Use the speed switch config interface 10 100 1000 auto configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port fastEthernet 2 switch config if speed 100 no flowcontrol Disable flow control of interface switch config if no flowcontrol security enable Enable security of interface switch config interface fastEthernet 2 switch config if security enable no security bandwidth type all Disable security of interface Set interface ingress limit frame type to accept all frame switch config interface fastEthernet 2 switch config if no security switch config interface fastEthernet 2 switch config if bandwidth type Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 39 all bandwidth type broadcast multicast floo ded unicast Set interface ingress limit frame type to accept broadcast multicast and flooded unicast
101. ting Ingress Limit Frame Type Egress Portoa d Kee 0 kee Port o2 Al ln kbps kbps Port 03 DIE 0 kee 0 Vape Port 04 al ln test Hops Port o5 Al zlln Vapelt kbps Portos slln kbpsjO kbps Porto7 Al zlln Vapelt kbps Portos ll kbpslO kbps Port oofal ln kbps O kbps Portao 40 kbpslO kbps Port iifAl ll kbps O kbps port 13lat dJO0 kbpsjO kbps Pot isfAl SiO kbpsjO kbps Port i4faAl zlln kbps O kbps port 1Slat ln kbpslo kbps Porti6 Al 4 0 kbpslO kbps Porti7 Al zo pelt kbps Portis ll kbps O kbps Rate Range Is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit Rate Limiting interface H Ingress Limit Frame type Select the frame type you want to filter The frame types have 4 options for selecting All Broadcast Multicast Flooded Unicast Broadcast Multicast and Broadcast only The four frame type options are for ingress frames limitation The egress rate only supports AIF type m All the ports support port ingress and egress rate control For example 84 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com assume port 1 is 10Mbps the user can set the effective egress rate of p
102. to refresh the events log Click Clear to clear all current events log Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 5 After configuring Click Apply System Event Log Syslog Configuration Syslog Configuration SMTP Configuration Event Configuration Syslog Client Mode Both Ba Apply Syslog Server IP Address 192 168 16 200 3 Jan 1 00 02 53 System Log Server IP 192 168 16 200 2 Jan 1 00 02 53 System Log Enable 1 Jan 1 00 02 18 Clear System Log Table Reload Clear Help Syslog Configuration interface System Event Log SMTP Configuration You can set up the mail server IP mail account password and forwarded email account for receiving the event alert 1 Email Alert Enable or disable the email alert function 2 SMTP Server IP Set up the mail server IP address when Email Alert enabled this function will then be available 3 Sender Type in an alias of the switch in complete email address format e g switch101 123 com to identify where the event log comes Manual Documentation Number EIR618 2SFP T_0708m 67 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100
103. tton Manual Documentation Number EIR618 2SFP T_0708m 99 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP Trap Configuration System Configuration Trap Configuration SNMPv3 Configuration Trap Managers Current Managers New Manager Remove Add 192 168 16 21 TrapHosti v1 IP Address 192 168 16 23 192 168 16 22 TrapHost2 v2 Community TrapHost3 Trap version yi v2c Help Trap Managers interface SNMPV3 Configuration Configure the SNMP V3 function Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove the unwanted context name User Profile Configure SNMP v3 user table m User ID Set up the user name H Authentication Password Set up the authentication password m Privacy Password Set up the private password H Click Add to add the context name H Click Remove to remove the unwanted context name 100 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Irelan
104. type and the limit rates are 100K 250Mbps Ingress filter packet type combination rules are Bandwidth control Broadcast Multicast Unknown Unicast packet Broadcast Multicast Broadcast packet only and all of packets The packet filter rate can be set from 100k to 250Mbps Supports Flow Control for Full duplex and Back Pressure Flow Control for Half duplex System Log Supports System log record and remote system log serve Supports SMTP Server and 6 e mail accounts for SMTP 7 receiving event alert Provides one relay output for port breakdown amp power fail Relay Alarm o Alarm Relay current carry ability 1A DC24V Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Up to 3 Trap stations SNMP Trap Cold start Port link up Port link down Authentication Failure Private Trap for power status Power Alarm configuration Fault Alarm X Ring topology change DHCP Provides DHCP Client DHCP Server function Provides DNS client feature Supports Primary and Secondary DNS Server SNTP Supports SNTP to synchronize system clock in Internet TFTP firmware update Firmware update TFTP backup and restore Configuration a ae Supports binary configuration file f
105. ual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 UL cUL CE EN60950 1 IEC60068 2 32 Free fall Stability testing IEC60068 2 27 Shock IEC60068 2 6 Vibration Relay output for port breakdown and power source failure Relay Alarm Alarm Relay Contact Rating 1A 24VDC Contacts normally open Manual Documentation Number EIR618 2SFP T_0708m 121 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com
106. uest number Use the 802 1x misc max request global configuration command to set the MAX requests switch config 8021x misc maxrequest 3 8021x misc reauthperiod sec Use the 802 1x misc reauth period global switch config 8021x misc reauthperiod 3000 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 53 8021x portstate disable reject accept configuration command to set the reauth period Use the 802 1x port state interface switch config interface fastethernet 3 authorize configuration switch config if 8021x portstate command to set the accept state of the selected port show 8021x E Displays a summary of switch gt show 8021x the 802 1x properties and also the port sates no 8021x G Disable 802 1x switch config no 8021x function TFTP Commands Set Netstar Commands Level Description Defaults Example backup G Save configuration to switch config backup flash backup_cfg TFTP and need to flash backup_cfg specify the IP of TFTP server and the file name of image restore flash restore_cfg G Get configuration from switch config restore TFTP
107. uration page to see the IGMP snooping information IP multicast addresses are in the range of 224 0 0 0 through 239 255 255 255 IGMP Protocol Enable or disable the IGMP protocol IGMP Query Select the IGMP query function as Enable or Auto to set the switch as a querier for IGMP version 2 multicast networks H Click Apply button 106 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com IGMP Configuration IP Address VLAN ID Member Port IGMP Snooping Enable D IGMP Query Auto DN Apply Help IGMP Configuration interface X Ring X Ring provides a faster redundant recovery than Spanning Tree topology The action is similar to STP or RSTP but the algorithms between them are not the same In the X Ring topology every switch should be enabled with X Ring function and two ports should be assigned as the member ports in the ring Only one switch in the X Ring group would be set as the master switch that one of its two member ports would be blocked called backup port and another port is called working port Other switches in the X Ring group are called working switches and their two member ports are called working ports When the failure of network
108. utton MAC Address Table Static MAC Addresses Static MAC Addresses MAC Filtering All Mac Addresses I MAC Address FFEEDDCCBBAA Port No Port 01 x Delete Help Static MAC Addresses interface MAC Filtering By filtering MAC address the switch can easily filter the pre configured MAC address and reduce the un safety You can add and delete filtering MAC address 114 Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com MAC Address Table MAC Filtering Static MAC Addresses MAC Filtering All Mac Addresses EEFFDDCCBBAA MAC Address BBAACCDDFFEE Delete Help MAC Filtering interface 1 MAC Address Enter the MAC address that you want to filter 2 Click Add button 3 Ifyou want to delete the MAC address from the filtering table select the MAC address and click Delete button All MAC Addresses You can view the port that connected device s MAC address and the related devices MAC address 1 Select the port 2 The selected port of static amp dynamic MAC address information will be displayed in here 3 Click Clear MAC Table to clear the current port static MAC address information on screen Manual
109. w IP Address Type in an IP address Low IP address is the Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 1 100 192 168 1 200 In contrast 192 168 1 100 is the Low IP address H High IP Address Type in an IP address High IP address is the end of the dynamic IP range For example dynamic IP is in the range between 192 168 1 100 192 168 1 200 In contrast 192 168 1 200 is the High IP address Subnet Mask Type in the subnet mask of the IP configuration Gateway Type in the IP address of the gateway in your network DNS Type in the Domain Name Server IP Address in your network Lease Time sec It is the time period that system will reset the dynamic IP assignment to ensure the dynamic IP will not been occupied for a long time or the server doesn t know that the dynamic IP is idle E And then click Apply DHCP Server System Configuration System Configuration Client Entries Port and IP Binding DHCP Server Disable Di Low IP Address 192 168 16 100 High IP Address 192 168 16 200 Subnet Mask 255 255 255 0 Gateway 192 168 16 254 DNS 0 0 0 0 Lea
110. witch config no snmpv3 user 50 Manual Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box User Name of SNMPv3 agent Test no snmpv3 access context name Context Name group Group Name security level NoAuthNoPriv AuthNoP riv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name Remove specified access table of SNMPv8 agent switch config no snmpv3 access context name Test group G1 security level AuthPr iv match rule Exact views V1 V1 Vi no snmpv3 mibview view View Name type Excluded Included sub oid OID Remove specified mibview table of SNMPV3 agent switch config no snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 Port Mirroring Commands Set Netstar Commands Level Description Example monitor RX TX Both Configure source port of monitor function switch config interface fastEthernet 2 switch config if monitor RX monitor rx Port ID G Gei RX destination switch config monitor rx 2 port of monitor function monitor tx Port ID G Gei TX destination port switch config monitor tx 3 o
111. witches tie for position as the root switch switch config interface fastEthernet 2 switch config if stp path priority 128 stp admin p2p l Auto True False Admin P2P of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge l True False Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge 46 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box Manual Documentation Number EIR618 2SFP T_0708m 040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com True stp admin non stp l True False Admin NonSTP of STP priority on this switch config interface fastEthernet 2 interface switch config if stp admin non s tp False show spanning tree E Displays a summary of switch gt show spanning tree the spanning tree states no spanning tree G Disable spanning tree switch config no spanning tree QOS Commands Set Netstar Commands Level Description Example qos policy G Select QOS policy switch config qos policy weighted fair strict scheduling weighted fair qos prioritytype G Setting of QOS priority switch confi
112. www bb europe com 102 Security Name User ID Assign the user name that you have set up in user table Group Name Set up the group name Click Add to add the context name Click Remove to remove the unwanted context name Access Table Configure SNMP v3 access table Context Prefix Set up the context name Group Name Set up the group Security Level Set up the access level Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify View Name Set up the notify view Click Add to add the context name Click Remove to remove the unwanted context name MIBview Table Configure MIB view table ViewName Set up the name Sub Oid Tree Fill the Sub OID Type Select the type excluded or included Click Add to add the context name Click Remove to remove the unwanted context name Manual Documentation Number EIR618 2SFP T_0708m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS Configuration Here you can configure Qos policy and priority setting per port priority setting COS and TOS setting QoS Policy and Priority Type H Qos Policy Select the QoS policy rule gt Using the 8 4 2
113. y IP7 Security IP8 Security IP9 Help IP Security interface User Authentication Change web management login user name and password for the management security issue 1 2 3 4 User name Type in the new user name The default is root Password Type in the new password The default is root Confirm password Re type the new password And then click Apply User Authentication User Name rot New Password Confirm Password Losse Apply Help User Authentication interface Manual Documentation Number EIR618 2SFP T_0708m 75 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Statistics The following information provides the current port statistic information 76 Port Displays the port number Type Displays the media type of the port Link The status of linking Up or Down State The user can set the state of the port as Enable or Disable via Port Control When the state is disabled the port will not transmit or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 bytes oversize CRC Align

Download Pdf Manuals

image

Related Search

Related Contents

Remote Card  E1465A/E1466A/E1467A Relay Matrix Switch Modules  BL-VT164W BL-VT164 - Central telephonique Panasonic  Using Web-based Management  Juillet – Août – Septembre 2015 - La Cité des métiers du Val  Deakin Card Disclosure Document - User guide  Leroy-Somer Alternateurs LSA 37.2 - Installation  TN31 Series 10-20kVA user manual V2,1  LA FICHE DE POSTE - CDG de Corse-du-Sud  FICHA DATOS TÉCNICOS AFLOJATODO  

Copyright © All rights reserved.
Failed to retrieve file