Home

Page

image

Contents

1. N A N N N O N A Parts connected by protective impedance separated N A by double or reinforced insulation Metal parts of Class Il appliances conductively connected to gas pipes or in contact with water separated from live parts by double or reinforced insulation N N N N N N 0 A N A TRF No lEC60335_2 15E Page 30 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Class ll appliances permanently connected to fixed wiring so constructed that the required degree of access to live parts is maintained after installation Parts serving as supplementary or reinforced insulation fixed so that they cannot be removed without being seriously damaged or so constructed that they cannot be replaced in an incorrect position and so that if they are omitted the appliance is rendered inoperable or manifestly incomplete Clearances and creepage distances over supplementary and reinforced insulation not reduced below values specified in clause 29 as a result of wear Clearances and creepage distances between live parts and accessible parts not reduced below values for supplementary insulation if wires screws etc become loose Supplementary and reinforced insulation designed or protected against deposition of dirt or dust Supplementary insulation of natural or synthetic rubber resistant to ageing or arranged and dimensioned so that creepage distances are not reduced bel
2. ELECTRICS CO LTD Sleeving Jiangyin Yuanda S T200 600V Electrical Material AWG18 Co Ltd S Coffee Mill includes Motor Hangyu Electronic HC5420 220 240V 50Hz Technology Co 230M 100W Ltd Class 120 E Stator 35 70Q 22 8 C Rotor 1 10 50 300 22 8 C magnet winding material copper 250V Tf 115 C Alternative Foshan Ji Hui BW series 250V Tf 115 C Electrical Appliance Co Ltd Alternative Chang Zhou City KW115 C 250V Tf 115 C EN 60730 2 2 Tong Li Electronic 40004418 Co Ltd Thermal cut out DongLiYa Electronics Factory EN 60 335 2 15 EN 60 335 2 14 Test with appliance UL E116091 EN 60335 2 15 Test with the appliance EN 60335 2 15 Test with the appliance EN 60335 2 15 Test with the EN 60 335 2 14 appliance Test with appliance UL E246632 EN 60335 2 14 Test with the appliance EN 60730 2 9 VDE 40022445 EN 60730 2 2 VDE 40019595 VDE EN 60 335 2 15 EN 60 335 2 14 Y2 capacitor Jyh Chung JY 2200pF 250V T125 IEC 60384 14 VDE Electronic Co Ltd 40015983 TRF No lEC60335_2 15E Page 77 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark Internal wiring ZHEJIANG 600V 18AWG T105 EN 60335 2 14 Tested with XINXIN appliance ELECTRONIC UL WIRE ROD CO E225383 LTD Alternative NINGBO 18AWG T105 EN 60335 2 14 Tested with YUNHUAN 600V appliance ELECTRONICS UL GROUP CORP E137395 Enclos
3. For appliances with supply cord current carrying conductors become taut before earthing conductor if the cord slips out of the cord anchorage 27 4 No risk of corrosion resulting from contact between metal of earthing terminal and other metal Adequate resistance to corrosion of coated or uncoated parts providing earthing continuity other than parts of a metal frame or enclosure Parts of steel providing earthing continuity provided N A at the essential areas with an electroplated coating thickness at least 5 um TRF No IEC60335_2 15E Page 48 of 110 Report No 130229 IEC 60335 2 15 Verdict Adequate protection against rusting of parts of N A coated or uncoated steel only intended to provide or transmit contact pressure In case of aluminium alloys precautions taken to N A avoid risk of corrosion Low resistance of connection between earthing P terminal and earthed metal parts This requirement does not apply to connections N A providing earthing continuity in the protective extra low voltage circuit provided that clearances of basic insulation are based on the rated voltage of the appliance P The printed conductors of printed circuit boards shall N A not be used to provide earthing continuity in hand held appliances They may be used to provide earthing continuity in N A other appliances if at least two tracks are used with independent soldering points and the appliance complies with 27 5 for ea
4. molten metal poisonous or ignitable gas in hazardous amounts in table 9 Compliance with cl 8 not impaired If the appliance can still be operated it complies with EN 20 2 Insulation other than of class III appliance withstand the electric strength test of 16 3 the test voltage specified in table 4 basic insulation reinforced insulation After operation or interruption of a control clearances and creepage distances across the functional insulation withstanding the electric strength test of 16 3 the test voltage being twice the working voltage The appliance does not undergo a dangerous malfunction and no failure of protective electronic circuits if the appliance is still operable P supplementary insulation TRF No IEC60335_2 15E Page 24 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark if they become operational do not result in a dangerous malfunction during or after the tests of During the test of 19 4 pressure relief devices of pressure cookers operate before pressure has reached 350 kPa IEC 60335 2 15 Appliances operated under the conditions of Clause 11 Contactors or relays contacts operating under the conditions of clause 11 short circuited Kettle operated empty at 0 85 times or 1 15 times rated power input whichever is more unfavourable thermal cut out rendered inoperative Any flames keep within the enclosure of the kettle and supporti
5. 2 15 7 12 1 Sufficient details for installation supplied PNA Stationary appliances not fitted with means for N A disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category Ill the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Insulation of the fixed wiring in contact with parts N A exceeding 50 K during clause 11 instructions stating that the fixed wiring must be protected Instructions for built in appliances N A dimensions of space N A P dimensions and position of supporting means Po N A P distances between parts and surrounding structure Po N A dimensions of ventilation openings and N A arrangement connection to supply mains and interconnection of N A separate components allow disconnection of the appliance after N A installation by accessible plug or a switch in the fixed wiring unless 7 12 5 Replacement cord instructions type X attachment N A with a specially prepared cord Replacement cord instructions type Y attachment Lay P P Replacement cord instructions type Z attachment LF N A 7 12 6 Caution in the instructions for heating appliances N A with a non self resetting thermal cut out TAZAS Instructions for fixed appliances stating how the N A appliance is to be fixed 7 12 8 Instructions for appliances connected to the water mains N A min inl
6. 2 15 Verdict Circuits supplied with a voltage lower than rated N A voltage clearances of functional insulation based on the working voltage used as the rated voltage in table 15 Creepage distances not less than those appropriate A for the working voltage taking into account the material group and the pollution degree Pollution degree 2 applies unless precautions taken to protect the insulation pollution Tubular sheathed heating P degree 1 element insulation subjected to conductive pollution pollution degree 3 The microenvironment is pollution degree 3 if the insulation can be polluted by condensation from steam produced during normal use of the appliance IEC 60335 2 15 Compliance is checked by inspection and measurements as specified Creepage distances of basic insulation not less than For pollution degree 1 creepage distance not less than the minimum specified for the clearance in table 16 if the clearance has been checked according to the test of clause 14 Creepage distances of supplementary insulation at least as specified for basic insulation in table 17 Creepage distances of reinforced insulation at least double as specified for basic insulation in table 17 Creepage distances of functional insulation not less than specified in table 18 Creepage distances may be reduced if the appliance complies with clause 19 with the functional insulation short circuited Supplementary and reinforced insulati
7. Il appliances N A IP number other than IPXO IPXO N A Symbol IEC 60417 5036 for the enclosure of N A electrically operated water valves in external hose sets for connection of an appliance to the water mains Appliances intended to be partially immersed in N A water for cleaning shall be marked with the maximum level of immersion and IEC 60335 2 15 with the substance of the following Do not N A immerse beyond this level IEC 60335 2 15 TRF No IEC60335_2 15E Page 6 of 110 Requirement Test Result Remark For kettles level mark which indicate the rated N A capacity IEC 60335 2 15 Unless they cannot be filled beyond their rated N A capacity IEC 60335 2 15 Mark outside of the kettle if the level is not self N A evident IEC 60335 2 15 Marking on the appliance of the closed position of N A the lid of pressure cooker if it is not obvious IEC 60335 2 15 Identification mark and Model or type reference of N A stand for cordless kettles IEC 60335 2 15 Warning for stationary appliances for multiple supply te N A Warning placed in vicinity of terminal cover Po N A Report No 130229 IEC 60335 2 15 Range of rated values marked with the lower and 220 240V P upper limits separated by a hyphen Different rated values marked with the values separated by an oblique stroke Appliances adjustable for different rated voltages the voltage setting is clearly discernible Appliances with more than one
8. N Nemko www nemko com TEST REPORT IEC EN 60335 2 15 Safety of household and similar electrical appliances Part 2 Particular requirements for appliances for heating liquids Report Reference No 130229 2009 12 10 A pr Andrew Zhai William Cheung ju 110 pages Date of issue PA Tested by name signature Approved by signature Total number of pages Nemko Hong Kong Ltd Phone 852 2675 0288 Unit 1 5 15 F CCT Telecom Building No 11 Wo Shing Street Fotan Shatin N T Hong Kong China Hangyu Group Co Ltd No 16 Beihu Road Economic Development Zone Yongkang Zhejiang China Test specification Standard X EN 60335 2 15 2002 A1 2005 A2 2008 with XX EN 60335 2 14 2006 A1 2008 with XX EN 60335 1 2002 A1 2004 A11 2004 A2 2006 A12 2006 A13 2008 XX EN 50366 2003 A1 2006 Test procedure Non standard test method Test Report Form No Test Report Form s Originator Master TRP arar 1EC60335 2 15E IMQ S p A Dated 2008 01 Copyright 2008 IEC System for Conformity Testing and Certification of Electrical Equipment IECEE Geneva Switzerland All rights reserved This publication may be reproduced in whole or in part for non commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material IECEE takes no responsibility for and will not assume liability for damages resulting
9. NOTE The values stated for pollution degree 2 are applicable 29 3 Replace the third dashed item by Replace an assessment of the thermal quality of the material combined with an electric strength test in accordance with 29 3 3 and for accessible reinforced insulation consisting of a single layer measurement in accordance with 29 3 Z1 EN60335 1 A12 If accessible reinforced insulation consists of a single layer the thickness of this layer shall comply with Table Z1 EN60335 1 A12 ANNEX ZB A deviation National deviation due to regulations normative the alteration of which is for the time being outside the Competence of the CEN CENELEC member Normative references to international publications with their corresponding European publications normative IEC and CENELEC code designations for flexible ZD cords informative Page 84 of 110 Report No 130229 Result Remark nl ANNEX ZA SPECIAL NATIONAL CONDITIONS EN 60335 1 2002 ITALY Only plugs listed in CENELEC Report ROBT 005 2001 are allowed Statuatory Instrument NO 105 of 1949 The voltage is 220 V 380 V DENMARK requirements regarding marking tag of power supply cord and connecting of earthing wire Page 85 of 110 MEA Report No 130229 Requirement Test Result Remark NORWAY the test is also applicable to appliances intended to be permanently connected to fixed FRANCE NORWAY The second paragr
10. TABLE Electric strength Test voltage applied between Voltage V Breakdown Yes No Live part and accessible parts over reinforced insulation 3000 Live part and accessible parts over basic insulation 1000 TRF No IEC60335_2_15E Page 71 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark 14 TABLE Transient overvoltages a between Cl mm Required Rated da Impulse a i aa mm Cc 4 A 162 peee O fe ia prase asnos 106 ate vote wv E Three phase appliances 1 06 x rated voltage Le divided by V3 civic Live part and accessible parts over basic insulation 163 3 TABLE Electric strength Test E applied between Voltage V EEEN Yes No Live part and accessible parts over reinforced insulation 3000 No Live part and accessible parts over basic insulation 1250 TABLE Overload protection temperature rise Temperature rise of part at dT K Max dT K TRF No IEC60335_2 15E Page 72 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Water pump measured by thermocouple during the first hour maximum value after the first hour maximum value after the first hour arithmetic average TABLE Abnormal operation running overload CO AIN 82 ETS AU IS A DO TRF No IEC60335_2 15E Page 73 of 110 Report No 130229 IEC 60335 2 15 Clause Requirement Test Result Rema
11. The bowl and cutting blades of food blenders and N A N A N A N A N A N A N A N A N A hand held blenders shall have adequate mechanical strength Compliance is checked by the specified test 25 5 o ES Z attachment allowed for N A N A N A N A can can openers o coffee mills and grain grinders having a mass not a 1 5 kg egg beaters N A ice cream machines including those for use in N A refrigerators and freezers Page 100 of 110 MEA Report No 130229 Requirement Test Result Remark Page 101 of 110 APPENDIX 5 Photos document Over view Report No 130229 2 f HYCO Y N A ESPRESSO MACHINE SELF SERVICE A Jo 7 Top view Page 102 of 110 Side view Report No 130229 Bottom view Page 103 of 110 Open view bottom enclosure opened Report No 130229 Page 104 of 110 Open view placement of water pump and PCB Report No 130229 Page 105 of 110 Details PCB Report No 130229 anon a Gee aa HO2B vty O Page 106 of 110 Open view cordless interface for coffee mill within the coffee maker Report No 130229 Overview of coffee mill Page 107 of 110 Bottom view of coffee mill Report No 130229 Open view of coffee mill the bottom of enclosure opened Page 108 of 110 Open view of coffee mill Report No 130229
12. at rated voltage with N A one phase disconnected Running overload test on appliances incorporating N A motors intended to be remotely or automatically controlled or liable to be operated continuously Winding temperatures not exceeding values as N A specified Series motor operated at 1 3 times rated voltage tor ll mill tested in Appendix N A During the test parts not being ejected from the N A appliance Electronic circuits compliance checked by P evaluation of the fault conditions specified in 19 11 2 for all circuits or parts of circuits unless they comply with the conditions specified in 19 11 1 Appliances incorporating a protective electronic N A circuit subjected to the tests of 19 11 3 and 19 11 4 Appliances having a switch with an off position Not possible unsafe operation P obtained by electronic disconnection or a switch placing the appliance in a stand by mode subjected to the tests of 19 11 4 Appliances incorporating an electronic circuit that N A relies upon a programmable component to function correctly subjected to the test of 19 11 4 8 Before applying the fault conditions a to f in 19 11 2 it is checked if circuits or parts P of circuit meet both of the following conditions TRF No IEC60335_2_15E Page 21 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark Verdict the electronic circuit is a low power circuit that is After T4 78L05 the
13. from the reader s interpretation of the reproduced material due to its placement and context If this Test Report Form is used by non IECEE members the IECEE IEC logo and the reference to the CB Scheme procedure shall be removed This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02 Test item description Trade Mark China Hangyu Group Co Ltd HES120A 220 240V 50Hz 1400W Class This Test Report when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory or by a laboratory having special agreement with Nemko Page 2 of 110 Name and address of production sites Factories Report No 130229 China Hangyu Group Co Ltd No 16 Beihu Road Economic Development Zone Yongkang Zhejiang China Copy of marking plate HYCO HES120A 220V 240V 50Hz 1400W China Hangyu Group Co Ltd TRF No lEC60335_2 15E Page 3 of 110 Summary of testing This appliance mainly function is for brewing coffee and one coffee mill is also incorporated with the appliance So EN 60335 2 14 is also considered in the appendix 4 Report No 130229 EMC standards EN 55014 1 2006 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EMF standard EN 50366 2003 A1 2006 List of attachments APPENDIX 1 includes the assessmen
14. load Working voltage of motors connected to the supply mains and having basic insulation that is inadequate for the rated voltage of the appliance not exceeding 42V Hose sets for connection of appliances to the water mains complying with IEC 61770 and supplied with the appliance Devices incorporated in appliance other than kettles in order to comply with 19 4 shall be non self resetting IEC60335 2 15 However self resetting thermal cut outs are allowed for fixed water boilers if they have been tested for 10 000 cycles of operation Compliance is checked by inspection an appliance inlet having at least the same degree of protection against moisture as required for the appliance Appliances incorporating an appliance inlet other than those standardized in IEC 60320 1 shall be Stationary appliance for multiple supply may be provided with more than one means of connection provided electric strength test of 1250 V for 1 min between each means of connection causes no breakdown TRF No IEC60335_2 15E Page 40 of 110 Report No 130229 IEC 60335 2 15 Verdict Connection of supply conductors for appliance intended to be permanently connected to fixed wiring possible after the appliance has been fixed to its support Appliance provided with a set of terminals for the connection of cables or fixed wiring cross sectional areas specified in 26 6 Appliance provided with a set of supply leads accommodated i
15. of N A the components are short circuited or open circuited 22 43 Appliances adjustable for different voltages N A accidental changing of the setting of the voltage unlikely to occur 22 44 Appliances shall not have an enclosure that is P shaped or decorated like a toy 22 45 When air is used as reinforced insulation clearances P not reduced below the values specified in 29 1 4 due to deformation as a result of an external force applied to the enclosure 22 46 Software used in protective electronic circuits is N A software class B or C 22 47 Appliances connected to the water mains withstand N A the water pressure expected in normal use No leakage from any part including any inlet water N A hose 22 48 Appliances connected to the water mains N A constructed to prevent backsiphonage of non potable water 22 49 For remote operation the duration of operation shall N A be set before the appliance can be started unless the appliance switches off automatically or can N A operate continuously without hazard 22 50 Controls incorporated in the appliance take priority N A over controls actuated by remote operation 22 51 A control on the appliance being manually adjusted N A to the setting for remote operation before the appliance can be operated in this mode TRF No IEC60335_2 15E Page 33 of 110 Requirement Test Result Remark There is a visual indication showing that the N A appliance is adjusted for remote operation Manual
16. rated voltage or one or more rated voltage ranges marked with rated input or rated current for each rated voltage or range unless the power input is related to the arithmetic mean value of the rated voltage range N A N A T2 13 7 4 D 7 N A Relation between marking for upper and lower limits of rated power input or rated current and voltage is clear Correct symbols used Connection diagram fixed to appliances to be connected to more than two supply conductors and appliances for multiple supply 7 8 Except for type Z attachment terminals for connection to the supply mains indicated P as follows marking of terminals exclusively for the neutral N A conductor N TRF No lEC60335_2 15E Nz NIO Page 7 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark marking of protective earthing terminals symbol 5019 of IEC 60417 7 9 Marking or placing of switches which may cause a hazard 10 Indications of switches on stationary appliances and By the characters amp picogram controls on all appliances by use of figures letters or near to the knob and the LED other visual means indicators confusion with the OFF position the appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction children being su
17. subjected to P needle flame test of annex E Test not applicable to conditions as specified ee N A RESISTANCE TO RUSTING Relevant ferrous parts adequately protected against rusting RADIATION TOXICITY AND SIMILAR HAZARDS Appliance shall not emit harmful radiation present a e toxic or similar hazard due to their operation in normal use Relevant tests specified in part 2 if necessary 31 32 ANNEX A INFORMATIVE ROUTINE TESTS Description of routine tests to be carried out by the manufacturer ANNEX B NORMATIVE APPLIANCES POWERED BY RECHARGEABLE BATTERIES v The following modifications to this standard are N A applicable for appliances powered by batteries that are recharged in the appliance This annex does not apply to battery chargers TRF No IEC60335_2_15E N A Page 57 of 110 Requirement Test Result Remark Report No 130229 IEC 60335 2 15 Appliance operated under the following conditions N A the appliance supplied by its fully charged battery N A operated as specified in relevant part 2 the battery is charged the battery being initially N A discharged to such an extent that the appliance cannot operate if possible the appliance is supplied from the supply N A mains through its battery charger the battery being initially discharged to such an extent that the appliance cannot operate The appliance is operated as specified in relevant part 2 If the appliance
18. together Thread cutting self tapping screws and thread N A rolling screws only used for electrical connections if they generate a full form standard machine screw thread N A Thread cutting self tapping screws not used if they are likely to be operated by the user or installer Thread cutting thread rolling and space threaded screws may be used in connections N A providing earthing continuity provided it is not necessary to disturb the connection when replacing a supply cord having a type X N A attachment or At least two screws being used for each connection N A providing earthing continuity unless the screw forms a thread having a length of at least N A half the diameter of the screw Thread cutting and space threaded screws may be N A used in connections providing earthing continuity provided unnecessary to disturb the connection and at least two screws are used for each connection TRF No IEC60335_2_15E Page 50 of 110 Requirement Test Result Remark Verdict Report No 130229 IEC 60335 2 15 Screws and nuts that make mechanical connection N A secured against loosening if they also make electrical connections or connections providing earthing continuity Rivets for electrical connections or connections P providing earthing continuity secured against loosening if subjected to torsion 29 CLEARANCES CREEPAGE DISTANCES AND SOLID INSULATION Clearances creepage distances and solid insu
19. water pump P connections motor 11 4 Heating appliances operated under normal operation 1753W 255 0V P at 1 15 times rated power input If the temperature rise limits are exceeded in N A appliances incorporating motors transformers or electronic circuits and if the power input is lower than the rated power input the test is repeated with the appliance supplied at 1 06 times rated voltage IEC 60335 2 15 N A 3 11 5 Motor operated appliances operated under normal operation at most unfavourable voltage between 0 94 and 1 06 times rated voltage TRF No IEC60335_2 15E Page 13 of 110 Report No 130229 IEC 60335 2 15 Combined appliances operated under normal operation at most unfavourable voltage between 0 94 and 1 06 times rated voltage Combined appliances are tested as heating appliances IEC 60335 2 15 11 7 Appliances are operated for the duration specified in 11 7 101 to 11 7 105 IEC 60335 2 15 11 7 101 For kettles with temperature limiter test terminated after second operation of temperature limiter For kettles with thermostat test terminated 15 min after the water has attained 95 C and 5 min after for others kettles 11 7 102 For cooking pans egg boilers feeding bottle heaters glue pots livestock feed boilers milk heaters sterilizers wash boilers and for appliances that boil water other than kettles the fest is terminated A1 2005 appliances without a thermal control 1
20. 20 400 560 80 0 1000 1120 1260 mo feo eso mo soo Tesora 200 eso no soo eso ro mo gt 5000 and lt 6300 126 0 142 0 160 0 gt 6300 and lt 8000 250 320 450 630 80 0 900 1000 NA 26300 and lt B000 25 0 320 eso 630 80 0 oo 1000 NA 26300 and lt 8000 50 0 640 900 126 0 1600 180 0 2000 _NA 40 0 560 80 0 1000 1100 1250 NA _ gt 8000 and lt 10000 320 400 560 800 1000 1100 1250 NA 2200 2500 MA gt 10000 and lt 12500 400 50 0 710 100 0 1250 140 0 1600 NA gt 10000 and lt 12500 40 0 50 0 710 100 0 125 0 140 0 1600 _NA gt 10000 and lt 12500 80 0 100 0 142 0 2000 2500 280 0 3200 NA B Basic S Supplementary and R Reinforced 0 L N earthing terminal within the cordless interface connection 4 2mm End of heating elements earthing metal 9 0mm The commutator motor axis 7 3mm the distance between winding and rotor 3 5mm gt 1 5mm 2 Internal wiring within stand accessible parts 5 0mm Live parts in the cordless interface connection accessible surface 15 3mm grinding switch terminal accessible part 11 4mm End of heating elements earthing enclosure of heating tubing inside surface 1 8 mm gt 1 0mm limit TABLE Creepage distances functional insulation P Working vo
21. 5 min after the water in the container has attained a temperature of 95 C or the maximum temperature it can attain if this is lower portable appliances 15 min after the thermal control has operated for the first time appliances with acoustic signal 1 min after signal For appliances having heated surface for keeping the liquid warm also until steady conditions with and without the container 11 7 103 Slow cookers steam cookers and yoghurt makers are operated until steady conditions are established Slow cookers are prewarmed in the dry state if this instruction is given 11 7 104 Espresso coffee makers are operated in accordance with the instructions for use Espresso coffee makers having an outlet for supplying steam or hot water before each rest period the brewing period is immediately followed by a period during which the steam or water is supplied for the time indicated in the instructions TRF No IEC60335_2 15E fixed appliances 30 min after the thermal control has operated for the first time Page 14 of 110 Requirement Test Result Remark Espresso coffee makers operated until steady P conditions 11 7 105 Pressure cookers operated 15 min after attaining the N A maximum cooking pressure Temperature rises not exceeding values in table 3 see appended tables P 13 13 1 13 2 13 3 14 Report No 130229 IEC 60335 2 15 Sealing compound does not flow out P Protective devices do not
22. N A the working tools while rotating at a speed exceeding 1500rev min 20 102 Blades of hand held blenders are completely N A screened from above and are not able to touch a flat surface while rotating Not possible to touch the blades with the end of the N A test rod diameter 8 mm and checked by inspection 20 103 Biased off switch of hand held blenders recessed or N A otherwise guarded Test with a cylindrical rod having a diameter of 40 mm and hemispherical end appliance does not operate 20 104 Not possible to operate the cutting blades of N A blenders other than hand held blenders while they are accessible test with test finger specified for blender 20 105 Centrifugal juicers N A N A N A lids and covers doe not open due to vibration rotating parts adequately secured against becoming loose during operation If speed of rotating parts gt 5000rev min lids and covers can only be closed after removal of tools N A N A teeth of grating disks do not exceed 1 5mm in height throw out cogs do not project more than 4mm feed pusher provided of a size that fills the throat of the hopper N A N A Page 97 of 110 MEA Report No 130229 Requirement Test Result Remark lids and covers do not open by force test of 5N Po N A 20 106 For appliances having a feed screw N A the maximum cross sectional dimension of the hopper not exceed 45 mm A feed p
23. P If the specimen does not withstand the test the test N A may be repeated on two additional specimens both withstanding the test P N A P ANNEX F NORMATIVE CAPACITORS Capacitors likely to be permanently subjected to the N A supply voltage and used for radio interference suppression or voltage dividing comply with the following clauses of IEC 60384 14 with the following modifications N A N A N A TRF No IEC60335_2 15E Page 60 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark TE b are applicable Po N A This subclause is applicable N A However for capacitors in heating appliances the N A values for test B or C apply Damp heat steady state N A This subclause is applicable N A Z 412 MN emia checked 413 MA i Impulse voltage N A This subclause is applicable N A Endurance N A N A Subclauses 4 14 1 4 14 3 4 14 4 and 4 14 7 applicable Only insulation resistance and voltage proof are N A checked N A Passive a PP test N A ANNEX G NORMATIVE SAFETY ISOLATING TRANSFORMERS TRF No lEC60335_2 15E Page 61 of 110 N Nemko Report No 130229 IEC 60335 2 15 Clause Requirement Test Result Remark The following modifications to this standard are N A applicable for safety isolating transformers 7 Marking and instructions N A 7 1 Transformers for specific use marked with N A name trademark or identification mark o
24. PC 5 220 240V 50Hz EN 60 335 2 41 Test with Electro 45W Class II EN 60 335 2 15 appliance Mechanical between water VDE Technology Co and live part of 40022290 Ltd pump Alternative Ulka Costruzioni EP5 230V 50Hz 48W EN 60 335 2 41 Test with Elettromeccaniche EN 60 335 2 15 appliance SrL VDE 40013711 Thermal cut out Jiangsu BR B3D 250V Tf 85 C EN 60730 2 2 Changsheng Electric Appliance Co Ltd Internal wiring NIZING 3122 300V T200 EN 60 335 2 15 Test with connected to ELECTRIC CO 16 18AWG appliance heating element LTD UL E215834 Alternative SHANGHAI 3122 300V T200 EN 60 335 2 15 Test with SHENYUAN 16 18AWG appliance HIGH UL TEMPERATURE E252215 WIRE CO LTD Alternative DONGGUAN 3122 300V T200 EN 60 335 2 15 Test with NISTAR 16 18AWG appliance TRANSMITTING UL TECHNOLOGY E214184 CO INC Internal wiring SHENZHEN 2468 300V T80 EN 60 335 2 15 Test with between PCB DONG JU WIRE 26AWG appliance amp CABLE CO LTD UL E189674 TRF No IEC60335_2 15E Page 75 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark YUEQING 2468 300V T80 EN 60 335 2 15 Test with A KANGHUA 26AWG appliance il ELECTRIC CO UL LTD E317788 YUEQING 2468 300V T80 EN 60 335 2 15 Test with BOYUAN 26AWG abtlla as Alternative ELECTRONIC P WIRE amp CABLE CO LTD E203561 Min thickness 0 3 EN 60 335 2 15 Test with EN 60 335 2 14 appliance ABS Min thickness 2 7 EN 60 335 2 15 Test with mm app
25. Page 109 of 110 Water boiler Report No 130229 Stator of the motor of coffee mill Page 110 of 110 Rotor of the motor of coffee mill Report No 130229
26. This subclause is not applicable N A ANNEX K NORMATIVE o CATEGORIES The information on overvoltage categories is P extracted from IEC 60664 1 Overvoltage category is a numeral defining a transient overvoltage condition Equipment of overvoltage category IV is for use at the origin of the installation Equipment of overvoltage category Ill is equipment in fixed installations and for cases where the reliability and the availability of the equipment is subject to special requirements Equipment of overvoltage category II is energy consuming equipment to be supplied from the fixed installation N A N A Equipment of overvoltage category is equipment for connection to circuits in which measures are taken to limit transient overvoltages to an appropriate low level ANNEX L INFORMATIVE GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES Sequences for the determination of clearances and P creepage distances ANNEX M NORMATIVE ER DEGREE If such equipment is subjected to special requirements with regard to reliability and availability overvoltage category Ill applies TRF No lEC60335_2 15E Page 65 of 110 Report No 130229 MEA IEC 60335 2 15 Requirement Test Result Remark The information on pollution degrees is extracted from IEC 60664 1 Pollution The microenvironment determines the effect of pollution on the insulation taking into account the microenvironment Means
27. X 2 EMF The Tested product also complies to the requirements of EN 50366 2003 A1 imi Measured max 1 2 Po Page 89 of 110 N Nemko Report No 130229 Requirement Test Result Remark APPENDIX 3 The assessment according to EN 60335 2 15 2002 A2 2008 5 101 Induction rice cookers are tested as motor operated appliances Add the following The instructions shall include the substance of the following This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses by clients in hotels motels and other residential type environments bed and breakfast type environments Addition NOTE 101 If the magnetic field of an induction rice cooker unduly influences the results the temperature rises can be determined using platinum resistances with twisted connecting wires or any equivalent means 11 7 103 After Slow cookers add rice cookers PY 11 7 104 Add the following after the first paragraph The maximum quantity is P limited by timer 30s For automatic espresso coffee makers and espresso coffee makers provided with a coffee pot the brewing period is the time necessary to produce the maximum quantity of coffee allowed by the timer or by the capacity of the coffee pot For manual espresso coffee makers if the N A maximum quantity of coffee to be produced is no
28. additional test with proof voltage N A reduced by 25V the number of drops increased to The report stating if the PTI value was based on a N A test using 100 drops with a test voltage of PTI 25 V ANNEX O INFORMATIVE SEO AND SEQUENCE OF THE TESTS OF CLAUSE 30 Description of tests for determination of resistance to P heat and fire USED IN WARM DAMP EQUABLE CLIMATES Modifications applicable for class O and 01 appliances having a rated voltage N A exceeding 150V intended to be used in countries having a warm damp equable climate and that are marked WDaE Modifications may also be applied to class 1 appliances having a rated voltage N A exceeding 150V intended to be used in countries having a warm damp equable climate and that are marked WdaE if liable to be connected to a supply mains that excludes the protective earthing conductor General conditions for the tests N A The ambient temperature for the tests of Clauses 11 N A and 13 is 40 Marking and instructions N A The appliance marked with the letters WDaE N A 7 12 The instructions state that the appliance is to be N A supplied through a RCD having a rated residual operating current not exceeding 30 mA TRF No lEC60335_2 15E ANNEX P INFORMATIVE os FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES Page 67 of 110 Clause Requirement Test Result Remark Verdict Report No 130229 IEC 60335 2 15 The instructions state that the app
29. after the appliance has being placed in the heating cabinet when cooled to room temperature the pins are not displaced by more than 1mm N A N A N A compliance with the standard Appliance for heating liquids and appliance causing undue vibration not provided with pins for insertion into socket outlets No risk of electric shock when touching the pins of the plug for appliances having a capacitor with rated capacitance exceeding 0 1uF the appliance being disconnected from the supply at the instant of voltage peak Electrical insulation not affected by condensing water or leaking liquid Electrical insulation of Class Il appliances not affected in case of a hose rupture or seal leak Drain holes shall be at least 5 mm in diameter or 705 mn in area with a width P 20 mm in area with a width of at least 3 mm of 4 7mm IEC 60335 2 15 Each pin subjected to a torque of 0 4Nm the pins are not rotating unless rotating does not impair TRF No IEC60335_2 15E Page 27 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Adequate safeguards against the risk of excessive N A pressure in appliances provided with steam producing devices __ Additional test for espresso coffee maker IEC 60335 2 15 N A Max pressure obtained with coffee filter blocked No pressure container N A and any steam valve closed test 5 min with twice this max pressure No rupture no abnormal leakage appli
30. ance fit for N A further use Max pressure test with pressure limiting devices N A made ineffective No explosion nor emission of dangerous jets of N A steam Last test repeated in case of rupture of an N A intentionally weak part the appliance shall be terminated in the same mode Pressure cooker test with six times the max N A nominal cooking pressure No rupture of container N A Electrical connections not subject to pulling during N A cleaning of compartments to which access can be gained without the aid of a tool and that are likely to be cleaned in normal use Insulation internal wiring windings commutators and slip rings not exposed to oil grease or similar substances Adequate insulating properties of oil or grease to which insulation is exposed N A Not possible to reset voltage maintained non self N A resetting thermal cut outs by the operation of an automatic switching device incorporated within the appliance N A Non self resetting thermal motor protectors have a trip free action unless they are voltage maintained N A TRF No IEC60335_2 15E Page 28 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Location or protection of reset buttons of non self N A resetting controls is so that accidental resetting is unlikely Reliable fixing of non detachable parts that provide the necessary degree of protection against electric shock moistur
31. and which can N A be operated only by a tool and switches operated by hand that are interlocked so that they cannot be operated under load are not subjected to the tests Subclauses 17 2 2 and 17 2 5 2 not applicable N A The ambient temperature during the test is that N A occurring in the appliance during the test of Clause 11 in IEC 60335 1 Report No 130229 IEC 60335 2 15 Temperature rise of the terminals not more than 30 K N A above the temperature rise measured in clause 11 of IEC 60335 1 Clearances creepage distances solid insulation and coatings of rigid printed board N A assemblies This clause is applicable to clearances and creepage N A distances for functional insulation across full disconnection and micro disconnection as stated in table 24 ANNEX NORMATIVE MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCE The following modifications to this standard are N A applicable for motors having basic insulation that is inadequate for the rated voltage of the appliance Protection against access to live parts N A Metal parts of the motor are considered to be bare N A live parts TRF No IEC60335_2 15E Page 63 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Temperature rise of the body of the motor is N A determined instead of the temperature rise of the windings Temperature rise of the body of the motor w
32. aph of this subclause dealing with single phase Class permanently connected appliances with heating elements is not applicable due to the supply AUSTRIA FINLAND GERMANY ICELAND IRELAND ITALY LUXEMBOURG NETHERLANDS NORWAY PORTUGAL SPAIN SWEDEN SWITZERLAND UNITED KINGDOM plugs according to Standard C3b not allowed DENMARK Supply cords of single phase portable appliances having a rated current not exceeding 13 A provided with a plug according to the following Class appliances Section 107 2 D1 Standard Sheet DK2 1a For appliances covered by a Part 2 of EN 60 335 also plugs in accordance with Section 107 2 D1 Standard Sheet C2b C3b or C4 are Class Il appliances Section 107 2 D1 Standard Sheet C1b C5 C6 DKA2 1a and DKA2 1b Stationary single phase appliances having a rated current not exceeding 13 A and provided with a plug the plug is in accordance with the requirements above Multi phase appliances and single phase appliances having a rated current exceeding 13 A and provided with a plug the plug is in accordance with the requirements below Class appliances Section 107 2 D1 Standard Sheet DK6 1a EN 60 309 2 Standard Sheet 2 11 2 Class Il appliances Section 107 2 D1 Standard Sheet DK6 1a 2 11 2 1V For max allowed current values see EN 60335 1 Page 86 of 110 MEA Report No 130229 Requirement Test Result Remark IRELAND plug is in accordance with Standard S
33. arded to prevent accidental operation Appliance don t operate when applying a cylindrical rod with diameter 40mm to the switch 20 116 Centrifugal juicers for fruit and vegetables shall be constructed so that parts cannot become N A N A disengaged when the appliance is operated at high speed Page 99 of 110 MEA Report No 130229 Requirement Test Result Remark N A Lid removed appliance supply at rated voltage and highest speed 10 times no part of appliance disengaged Lid in position when the speed reaches its N A maximum value attempt is made to remove the lid 10 times no part of appliance disengaged 20 117 Centrifugal juicers shall withstand the stresses resulting from parts rotating at high speed Compliance is checked by the following test which is carried out on three new appliance Or by testing the sieve in accordance with Annex AA The rim of plastic material retaining the rotating sieve is cut If the sieve retains its structure the rim is cut further and the test repeated until disintegration takes place During the test parts shall not be ejected from the appliance 20 118 The operation of cordless appliances incorporating cutting blades that are accessible to test probe B of IEC 61032 shall require two separate movements unless the control device is not directly accessible to the probe Compliance is checked by inspection and by manual test 20 119
34. art of a specially prepared cord Report No 130229 IEC 60335 2 15 N A N A screws which have to be operated when replacing N A the cord do not fix any other component if applicable if labyrinths can be bypassed the test of 25 15 is N A nevertheless withstood for Class 0 Ol and appliances they are of insulating material or are provided with an insulating lining unless a failure of the insulation of the cord does not make accessible metal parts live N A for Class II appliances they are of insulating N A material or if of metal they are insulated from accessible metal parts by supplementary insulation Adequate cord anchorages for type Y and Z attachment Cord anchorages only accessible with the aid of a tool or so constructed that the cord can only be fitted with the aid of a tool A N A Type X attachment glands not used as cord anchorage in portable appliances Tying the cord into a knot or tying the cord with string not used y Conductors of the supply cord for type Y and Z attachment adequately additionally insulated N A 25 17 25 18 25 19 25 20 TRF No IEC60335_2 15E Page 44 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Space for supply cord for type X attachment or for connection of fixed wiring constructed to permit checking of conductors with respect to correct positioning and connection before fitting any cove
35. ating element connected to the The test is not carried out on appliances intended to be permanently connected to fixed wiring and on appliances where an all pole disconnection occurs during the test of 19 4 Appliances with PTC heating elements tested at rated voltage establishing steady conditions The working voltage of the PTC heating element is increased by 5 and the appliance is operated until steady conditions are re established The voltage is then increased in similar steps until 1 5 times working voltage or until the PTC heating element ruptures Stalling test by locking the rotor if the locked rotor torque is smaller than the full load torque or locking moving parts of other appliances Locked rotor motor capacitors open circuited or short circuited if required Locked rotor capacitors open circuited one at a time TRF No IEC60335_2 15E Page 20 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Test repeated with capacitors short circuited one at a N A time if required Appliances with timer or programmer supplied with N A rated voltage for each of the tests for a period equal to the maximum period allowed Other appliances supplied with rated voltage for a N A period as specified Espresso coffee makers are operated for a period P of 5 min IEC 60335 2 15 Winding temperatures not exceeding values see appended table P specified in table 8 Three phase motors operated
36. ating member of slide switch located so that unintentional actuation is unlikely and actuated with force at least 5N N A N A 20 110 The cutting blades of bean slicers are at least 30 mm from the plane of the inlet opening length of the major and minor axis of the inlet and outlet openings not exceed 30 mm and 15 mm dimensions of outlet openings not limited if N A N A compliance with test specified 20 111 The rotating parts of graters and shredders N A are secured so that they are not liable to become loose during operation a feed pusher shall be provided which fills the throat of the hopper 20 112 The cutting blade of food processors stopped within 1 5 s after the lid has been opened or removed 20 113 The lid interlock of food processors shall be constructed so that accidental operation of the appliances is prevented Lid interlock switches shall be biased off switches If there is an interlock between the lid and the main switch the lid shall be locked when the switch is in the on position When the lid is not correctly closed the switch shall be locked in the off position 20 114 Access to dangerous moving parts of food processors prevented for all combinations of assembly of detachable parts that allow the motor to operate comply with test as specified N A N A N A N A N A N A N A 20 115 Knives shall incorporate a biased off switch that is N A recessed or gu
37. ch circuit Fixings electrical connections and connections providing earthing continuity withstand mechanical stresses Screws not of soft metal liable to creep such as zinc P or aluminium Diameter of screws of insulating material min 3 mm N A Screws of insulating material not used for any N A electrical connection or connections providing earthing continuity Screws used for electrical connections or No such screws N A connections providing earthing continuity screw into metal Screws not of insulating material if their replacement N A by a metal screw can impair supplementary or reinforced insulation TRF No IEC60335_2 15E Page 49 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Type X attachment screws to be removed for N A replacement of supply cord or for user maintenance not of insulating material if their replacement by a metal screw can impair basic insulation For screws and nuts test as specified see appended table P Electrical connections and connections providing earthing continuity constructed so that contact pressure not transmitted through insulating material liable to shrink or distort unless shrinkage or distortion compensated This requirement does not apply to electrical N A connections in circuits carrying a current not exceeding 0 5A Space threaded sheet metal screws only used for N A electrical connections if they clamp the parts
38. ct the blender from the supply if it N A is left unattended and before assembling disassembling or cleaning do not allow children to use the blender without N A supervision Accessories other than those supplied with the N A appliance shall include instructions for their safe use The instructions shall include details on how to clean surfaces in contact with food IEC 60335 2 14 2006 The instructions for appliances incorporating a switch necessary for compliance with N A 22 40 shall include the substance of the following IEC 60335 2 14 2006 Switch off the appliance before changing accessories No such switch N A or approaching parts which move in use 11 1 No excessive temperatures in normal use Po P 11 2 Placing and mounting of appliance as described within the appliance P 11 3 Temperature rises other than of windings P determined by thermocouples Temperature rises of windings determined by P resistance method unless the windings makes it difficult to make the necessary N A connections Page 93 of 110 MEA Report No 130229 Requirement Test Result Remark 11 4 Heating appliances operated under normal operatio N A at 1 15 times rated power input ceeees 11 5 Motor operated appliances operated under normal 1 06 times rated voltage P operation at most unfavourable voltage between 0 94 254 4V is the most and 1 06 times rated voltage a an unfavourable vo
39. d and similar connections may be used For Class II appliances the conductor so positioned or fixed that reliance is not placed on soldering welding or crimping alone TRF No IEC60335_2 15E Page 47 of 110 Requirement Test Result Remark Verdict Report No 130229 IEC 60335 2 15 For Class Il appliances soldering welding or N A crimping alone used barriers provided clearances and creepage distances satisfactory if the conductor becomes free 27 PROVISION FOR EARTHING 27 1 Accessible metal parts of Class Ol and appliances permanently and reliably connected to an earthing terminal or contact of the appliance inlet Earthing terminals not connected to neutral terminal Class 0 Il and III appliance have no provision for earthing Safety extra low voltage circuits not earthed unless protective extra low voltage circuits Clamping means adequately secured against accidental loosening Terminals used for the connection of external equipotential bonding conductors allow connection of 212 N A conductors of 2 5 to 6 mm and do not provide earthing continuity between different parts of the appliance Conductors cannot be loosened without the aid of a tool N A N A 21 3 For detachable parts that are plugged into another part of the appliance and having an earth connection the earth connection made before and separated after current carrying connections when removing the part
40. d to two times 90 for a period of 5 min the support being placed at the level of the pivot axis of the oscillating tube Appliances normally fixed to a ceiling are mounted N A underneath a horizontal unperforated support the pivot axis of the oscillating tube located at the level of the underside of the support For IPX4 appliances the movement of the tube is N A limited to two times 90 from the vertical for a period of 5 min Wall mounted appliances take into account the distance to the floor stated in the instructions Appliances with type X attachment fitted with a flexible cord as described N A N A N A Detachable parts tested as specified 15 2 Spillage of liquid does not affect the electrical insulation Appliances with type X attachment fitted with a flexible cord as described Appliances incorporating an appliance inlet tested with or without an connector whichever is most unfavourable Detachable parts removed Overfilling test with additional amount of 0 251 P water over a period of 1 min I i o The appliance withstands the electric strength test of 16 3 N A N A No trace of water on insulation that can result in a P reduction of clearances and creepage distances below values specified in clause 29 The test is only carried out with the appliance Connecting device for coffee P connector in position IEC 60335 2 15 mill checked spillage tests with a deviation from the normal 5 P posit
41. dance with its marking tested under the conditions occurring in the appliance Lampholders and starterholders not being tested and N A found to comply with the relevant IEC standard tested as a part of the appliance and additionally according to the gauging and interchangeability requirements of the relevant IEC standard Capacitors likely to be permanently subjected to the supply voltage and used for radio interference suppression or for voltage dividing complying with IEC 60384 14 or tested according to annex F Safety isolating transformers complying with IEC 61558 2 6 or N A N A N A tested according to annex G Switches complying with IEC 61058 1 the number of Interlock switch within coffee P cycles of operation being at least 10 000 or mill N A tested according to annex H TRF No IEC60335_2_15E Page 37 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark If the switch operates a relay or contactor the N A complete switching system is subjected to the test Switches in espresso coffee makers tested for N A 10 000 cycles IEC 60335 2 15 Automatic controls complying with IEC 60730 1 with relevant part 2 The number of N A cycles of operation being thermostats 10 000 Approved N A temperature limiters 1 000 Po N A self resetting thermal cut outs 300 Po N A voltage maintained non self resetting N A thermal cut outs Thermal motor protectors a
42. e 16 subjected to an impulse voltage test the test voltage specified in table 6 N A In case of flashover of functional insulation the N A appliance complies with clause 19 with the clearance short circuited N A Compliance checked as specified in 15 1 1 taking N A into account 15 1 2 followed by the electric strength test of 16 3 No trace of water on insulation which can result in a N A reduction of clearances and creepage distances below values specified in clause 29 Appliances other than IPX0 subjected to tests as N A specified in IEC 60529 Water valves in external hoses for connection of an N A appliance to the water mains tested as specified for IPX7 appliances N A Built in appliances installed according to the N A instructions Appliances placed or used on the floor or table N A placed on a horizontal unperforated support Appliances normally fixed to a wall and appliances N A with pins for insertion into socket outlets are mounted on a wooden board For IPX3 appliances the base of wall mounted N A appliances is placed at the same level as the pivot axis of the oscillating tube TRF No IEC60335_2 15E Page 16 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict For IPX4 appliances the horizontal centre line of the N A appliance is aligned with the pivot axis of the oscillating tube However for appliances normally used on the floor N A or table the movement is limite
43. e at the terminals of tubular sheathed heating elements may be reduced to 1mm if the microenvironment is pollution degree 1 Lacquered conductors of windings considered to be bare conductors Clearances of supplementary insulation not less than those specified for basic insulation in table 16 Clearances of reinforced insulation not less than those specified for basic insulation in table 16 but using the next higher step for rated impulse voltage For functional insulation the values of table 16 are applicable unless the appliance complies with clause 19 with the functional insulation short circuited However clearances at crossover points are not measured Clearance between surfaces of PTC heating elements may be reduced to 1mm Appliances having higher working voltage than rated voltage the voltage used for determining clearances from table 16 is the sum of the rated impulse voltage and the difference between the peak value of the working voltage and the peak value of the rated voltage If the secondary winding of a step down transformer is earthed or if there is an earthed screen between the primary and secondary windings clearances of basic insulation on the secondary side not less than those specified in table 16 but using the next lower step for rated impulse voltage Lacquered conductors of windings considered to be bare conductors TRF No IEC60335_2 15E Page 52 of 110 Report No 130229 IEC 60335
44. e or contact with moving parts Obvious locked position of snap in devices used for fixing such parts No deterioration of the fixing properties of snap in MA devices used in parts that are likely to be removed during installation or servicing Tests as described Handles knobs etc fixed in a reliable manner Fixing in wrong position of handles knobs etc indicating position of switches or similar components not possible Axial force 15 N applied to parts the shape being so Function selection knob P that an axial pull is unlikely to be applied Axial force 30 N applied to parts the shape being so that an axial pull is likely to be applied Unlikely that handles when gripped as in normal use make the operators hand touch parts having a temperature rise exceeding the value specified for handles which are held for short periods only No ragged or sharp edges creating a hazard for the user in normal use or during user maintenance N A Storage hooks and the like for flexible cords smooth and well rounded Automatic cord reels cause no undue abrasion or damage to the sheath of the flexible cord no breakage of conductors strands no undue wear of contacts Cord reel tested with 6000 operations as specified N A N A No exposed pointed ends of self tapping screws etc liable to be touched by the user in normal use or during user maintenance TRF No lEC60335_2 15E Page 29 of 110 Requirement Test Resu
45. e range shall cover 220 240V 230 V for single phase appliances 400 V for multi phase appliances Delete the second paragraph of the requirement Annex G normative Safety isolating transformers 24 1 7 Replace by If the remote operation of the appliance is via a telecommunication network the relevant standards for the telecommunication interface circuitry in the appliance are EN 41003 and EN 60950 1 2006 Subclause 6 3 EN60335 1 A13 Supply cords of single phase portable appliances having a rated current not exceeding 16 A shall be provided with a plug complying with the following standard sheets of IEC 60083 1975 for Class appliances standard sheet C2b C3b or C4 for Class II appliances standard sheet C5 or C6 Add ordinary polychloroprene sheathed flexible cord code designation 60245 IEC 57 HO5RN F When supply cords having high flexibility are used they shall not be lighter than rubber insulated and sheathed cord code designation 60245 IEC 86 HO3RR he rubber insulated crosslinked PVC sheathed cord code designation 60245 IEC 87 HO3RV4 H crosslinked PVC insulated and sheathed cord code designation 60245 IEC 88 HO3V4V4 H Requirement Test NOTE Z1 The harmonized code designations corresponding to the IEC cord types are given in Annex ZD 29 Replace the text by the following 29 1 29 2 and 29 3 The distances specified in items 2a 2c and 3 in Table 13 of IEC 61558 1 apply
46. es 30 2 2 applies Appliances operated while attended parts of non metallic material supporting current carrying connections and parts of non metallic material within a distance of 3mm of such connections are subjected to the glow wire test of IEC 60695 2 11 The glow wire test is not carried out on parts of material classified as having a glow wire flammability index according to IEC 60695 2 12 of at least TRF No IEC60335_2 15E Page 55 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark 750 C for connections carrying a current exceeding N A 0 5A during normal operation Test as specified for an interposed shielding material Po N A P When the glow wire test of IEC 60695 2 11 is carried out the temperatures are P 750 C for connections carrying a current exceeding see appended table P 0 5A during normal operation Test not applicable to conditions as specified AN N A 30 2 3 Appliances operated while unattended tested as N A specified in 30 2 3 1 and 30 2 3 2 Tests not applicable to conditions as specified Y N A Parts of insulating material supporting connections N A carrying a current exceeding 0 2A during normal operation and parts of non metallic material within a distance of a N A subjected to the glow wire test of IEC 60695 2 11 N A with a test severity of 850 C Glow wire test not carried out on parts of material N A classified as having a glow wire flammability i
47. et water pressure if necessary Pa E A N A TRF No lEC60335_2 15E Page 10 of 110 Report No 130229 IEC 60335 2 15 Verdict Instructions concerning new and old hose sets for N A appliances connected to the water mains by detachable hose sets Instructions and other texts in an official language English and German P instruction manuals are checked Marking clearly legible and durable P Marking on a main part P Marking clearly discernible from the outside if P necessary after removal of a cover For portable appliances cover can be removed or N A opened without a tool For stationary appliances name trademark or N A identification mark and model or type reference visible after installation For fixed appliances name trademark or N A identification mark and model or type reference visible after installation according to the instructions Indications for switches and controls placed on or P near the components Marking not on parts which can be positioned or repositioned in such a way that the marking is misleading Marking of a possible replaceable thermal link or N A fuse link clearly visible with regard to replacing the link PROTECTION AGAINST ACCESS TO LIVE PARTS Adequate protection against accidental contact with live parts Requirement applies for all positions detachable parts removed Insertion or removal of lamps protection against N A contact with live parts of the lamp cap Use of test
48. f the N A manufacturer or responsible vendor model or type reference Po N A 17 Overload protection of transformers and associated circuits N A Fail safe transformers comply with subclause 15 5 of N A IEC 61558 1 2 Construction N A Subclauses 19 1 and 19 1 2 of IEC 61558 2 6 are N A applicable 9 Clearances creepage distances and solid insulation N A 29 1 29 2 The distances specified in items 2a 2c and 3 in table N A and 29 3 13 of IEC 61558 1 apply ANNEX H NORMATIVE SWITCHES Switches comply with the following clauses of IEC 61058 1 as modified N A N N The tests of IEC 61058 1 carried out under the N A conditions occurring in the appliance Before being tested switches are operated 20 times N A without load Marking and documentation N A Switches are not required to be marked Po N A However switches that can be tested separately N A from the appliance marked with the manufacturer s name or trade mark and the type reference The tests may be carried out on a separate sample Po N A Insulation resistance and dielectric strength N A TRF No IEC60335_2 15E Page 62 of 110 Requirement Test Result Remark 15 3 Applicable for full disconnection and micro N A disconnection Compliance is checked on three separate appliances N A or switches For 17 2 4 4 the number of cycles is 10 000 unless N A otherwise specified in 24 1 3 of the relevant part 2 of IEC 60335 Switches for operation under no load
49. ft in this position for 10 s and then returned to its normal position TRF No IEC60335_2 15E Page 34 of 110 Requirement Test Result Remark aa The rate of discharge of liquid does not exceed 16 ee N A l min 22 105 Fixed appliances for boiling water o N A Container always open to the atmosphere N A Drain hole diameter 5 mm or area 20 mm with N A a width 3 mm Aperture not likely to be obstructed in normal use N A If the appliance has provisions for discharging N A steam or water overflowing the discharge aperture shall be at the base of the appliance and shall discharge vertically downwards Report No 130229 IEC 60335 2 15 Espresso coffee maker impossible to remove the No hazardous pressure within N A filter by a simple operation while hazardous container pressure within the container Pressure cookers shall incorporate a non self N A resetting pressure or temperature responsive pressure relief device Pressure cooker not possible to remove the lid N A when the inner pressure is excessive Pressure test at 4 kPa and 100 N N A No hazardous displacement of lid at removal N A Feeding bottle heater visible or audible signal to N A indicate the end of the heating period Kettles constructed so that they are no sudden jets N A of steam or hot water likely to expose the user to a hazard Espresso coffee makers incorporating a N A pressurized reservoir filled by the user shall be const
50. heets B2 and C2b see annex ZB as well ITALY Only plugs listed in CENELEC Report ROBT 005 2001 are allowed SPAIN For household appliances the following plugs only are allowed 5b SWITZERLAND supply cords of portable household and similar electrical appliances rated current not exceeding 10 A provided with a plug complying with SEV 1011 or IEC 60884 1 and one of the following dimension sheets SEV 6532 2 1991 plug type 15 N A 3P N PE 250 400 V 10 A SEV 6533 2 1991 plug type 11 L N 250 V 10A UNITED KINGDOM plug according to Standard Sheet B2 or C5 used refer to Annex ZB SEV 6534 2 1991 plug type 12 L N PE 250 V 10 A IRELAND UNITED KINGDOM replacement of figures rated current cross sectional area in the ANNEX ZB A DEVIATIONS EN 60335 1 2002 a SWITZERLAND information about batteries 71 ITALY the voltage is 220 V 380 V only SPAIN the voltages are 127 V 220 V and 220 220V only V 380 V 25 6 IRELAND UNITED KINGDOM regulations concerning plugs to be fitted to domestic appliances GROUP DIFFERENCES to IEC 60335 2 15 5th edition 2002 Amendment 1 2005 Page 87 of 110 Report No 130229 Requirement Test Result Remark The text of the International Standard IEC 60335 2 15 2002 Amendment1 2005 was approved by CENELEC as a European Standard without any modification Page 88 of 110 Report No 130229 Requirement Test Result Remark APPENDI
51. here in N A contact with insulating material not exceeding values in table 3 for the relevant insulating material Leakage current and electric strength N A Insulation between live parts of the motor and its N A other metal parts not subjected to the test Abnormal operation N A The tests of 19 7 to 19 9 not carried out Po N A 19 101 Appliance operated at rated voltage with each of the following fault conditions N A short circuit of the terminals of the motor including N A any capacitor incorporated in the motor circuit short circuit of each diode of the rectifier PNA open circuit of any parallel resistor the motor being N A in operation Only one fault simulated at a time the tests carried N A out consecutively 22 101 For class appliances incorporating a motor supplied N A by a rectifier circuit the d c circuit being insulated from accessible parts of the appliance by double or reinforced insulation Compliance checked by the tests specified for N A double and reinforced insulation J ANNEX J NORMATIVE COATED PRINTED CIRCUIT BOARDS Testing of protective coatings of printed circuit N A boards carried out in accordance with IEC 60664 3 with the following modifications Conditioning of the test specimens N A When production samples are used three samples N A of the printed circuit board are tested TRF No IEC60335_2 15E Page 64 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark
52. iance with 19 101 relies on the operation of a self resetting thermal cut out are subjected 19 102 IEC 60335 2 15 Appliances are placed as near as possible to the walls of the test corner IEC 60335 2 15 Test of appliance with heating elements with 217V 1089W restricted heat dissipation test voltage V power input of 0 85 times rated power input They are tested empty with lids open or closed whichever is the more unfavourable IEC 60335 2 15 TRF No IEC60335_2 15E Page 19 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Test of 19 2 repeated test voltage V power input 264V 1890W of 1 24 times rated power input Kettles are operated empty at 1 15 times rated power input IEC 60335 2 15 The test is carried out with the kettle filled with sufficient water to cover the heating element or if the heating element is not positioned inside the container to a depth of 10 mm IEC 60335 2 15 Test conditions as in cl 11 any control limiting the temperature during tests of cl 11 short circuited Pressure regulators of pressure cookers are rendered inoperative together with each protective device in turn IEC 60335 2 15 Test of 19 4 repeated on Class OI and appliances with tubular sheathed or embedded heating elements No short circuiting but one end of the element connected to the elements sheath The test repeated with reversed polarity and the other end of the he
53. incorporates inductive coupling N A between two parts that are detachable from each other the appliance is supplied from the supply mains with the detachable part removed 3 6 2 Part to be removed in order to discard the battery is N A not considered to be detachable 5 101 Appliances supplied from the supply mains tested as N A specified for motor operated appliances 7 1 Battery compartment for batteries intended to be N A replaced by the user marked with battery voltage and polarity of the terminals 7 12 The instructions for appliances incorporating N A batteries intended to be replaced by the user includes required information Details about how to remove batteries containing N A materials hazardous to the environment given 7 15 Markings placed on the part of the appliance N A connected to the supply mains 8 2 Appliances having batteries that according to the N A instruction may be replaced by the user need only have basic insulation between live parts and the inner surface of the battery compartment If the appliance can be operated without batteries N A double or reinforced insulation required The battery is charged for the period described PO N A Appliances subjected to tests of 19 101 19 102 and EN N A 19 103 TRF No lEC60335_2 15E Page 58 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark N A Short circuiting of the terminals of the battery being N A fully charged for appliances hav
54. ing batteries that can be removed without the aid of a tool Appliances having batteries replaceable by the user N A supplied at rated voltage under normal operation with the battery removed or in any position allowed by the construction Appliances having pins for insertion into socket N A outlets have adequate mechanical strength checked according to procedure 2 of IEC 68 2 32 Part of the appliance incorporating the pins subjected to the free fall test procedure 2 N A of IEC 60068 2 32 the number of falls being N A N A N A N A An additional lining or bushing not required for N A interconnection cords operating at safety extra low voltage N A N A ANNEX C NORMATIVE AGEING TEST ON MOTORS Tests as described carried out when doubt with N A regard to the temperature classification of the insulation of a motor winding The value of p in Table C 1 is 2000 N A IEC 60335 2 15 ANNEX D NORMATIVE THERMAL MOTOR PROTECTORS TRF No IEC60335_2 15E Page 59 of 110 Requirement Test Result Remark Report No 130229 IEC 60335 2 15 Applicable to appliances having motors that The thermal motor protector N A incorporate thermal motor protectors within in the motor for coffee mil is not operated during all electrical testing ANNEX E NORMATIVE NEEDLE FLAME TEST P P P P The specimen so arranged that the flame can be P applied to a vertical or horizontal edge as shown in the examples of figure 1 P P
55. ion TRF No IEC60335_2 15E Page 17 of 110 Requirement Test Result Remark Verdict N A Report No 130229 IEC 60335 2 15 Steam sterilizers particular overfilling test in conditions as specified A1 2005 Cordless kettles particular overfilling test in N A conditions as specified A1 2005 Kettles particular overfilling test in conditions as N A specified A1 2005 15 101 Appliances to be immersed in water for cleaning sufficiently protected against effects of immersion Testing conditions and scheduling as specified N A N A No trace of water on insulation which can result in N A reduction of creepage distances and clearance below values specified in 29 15 102 Cordless kettles particular electric strength test in conditions as specified Stand withstanding the test of 16 3 with voltage reduced to 2500 V for reinforced insulation N A N A 15 3 Appliances proof against humid conditions Humidity test for 48 h in a humidity cabinet 25 C 95 The appliance withstands the tests of clause 16 LEAKAGE CURRENT AND ELECTRIC STRENGTH 16 1 Leakage current not excessive and electric strength adequate Protective impedance disconnected from live parts N A before carrying out the tests 16 2 Single phase appliances test voltage 1 06 times 254 4V P rated voltage Three phase appliances test voltage 1 06 times N A rated voltage divided by V3 Leakage current measure
56. ionary appliances other than those of electrical components provided they are either reliably connected to an earthing terminal or earthing contact or separated from live parts by earthed Handles continuously held in the hand in normal use are so constructed that when gripped as in normal use the operators hand is not likely to touch metal parts unless they are separated from live parts by double or reinforced insulation Metal casings of capacitors in Class Il appliances separated from accessible metal parts by supplementary insulation unless complying with 22 42 Capacitors not connected between the contacts of a thermal cut out Motor operated appliances and combined appliances intended to be moved while in operation or having accessible moving parts fitted with a switch to control the motor The actuating member of the switch being easily visible and accessible TRF No IEC60335_2 15E Page 32 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Unless the appliance can operate continuously N A automatically or remotely without giving rise to a hazard appliances for remote operation being fitted with a switch The actuating member of the switch being easily visible and accessible 22 41 No components other than lamps containing P mercury 22 42 Protective impedance consisting of at least two N A separate components Values specified in 8 1 4 not exceeded if any one
57. its stand The instructions for use for feeding bottle heaters shall state N A that the food should not be heated for too long a N A period how to check that the correct food temperature N A has not been exceeded Report No 130229 IEC 60335 2 15 The instructions for use for appliances normally P cleaned after use and not intended to be immersed in water for cleaning shall state that the appliance must not be immersed Pressure cooker N A The instructions for use for pressure cookers shall N A state that the ducts in the pressure regulator allowing the escape of steam should be checked regularly to ensure that they are not blocked They shall also give details of how to open the N A container safely and state that the container must not be opened until N A the pressure has decreased sufficiently The instructions for use for egg boilers provided with a pricking device shall contain N A the substance of the following Caution Avoid injuries from the egg pricker Po N A For espresso coffee makers incorporating a No pressurized reservoir N A pressurized reservoir filled by the user the instructions shall contain information for the safe refilling of the water reservoir and the substance of the following A1 2005 WARNING The filling aperture must not be opened N A during use TRF No IEC60335_2 15E Page 9 of 110 Requirement Test Result Remark Report No 130229 IEC 60335
58. ked rotor capacitors open circuited one at a time Test repeated with capacitors short circuited one at a time if required E l Requirement Test Appliances with timer or programmer supplied with rated voltage for each of the tests for a period equal to the maximum period allowed Berry juice extractors blenders for food centrifugal juicers for fruit and vegetables food mixers food processors and mincers are operated for 30 s Coffee mills grain grinders and noodle makers are tested for 5 min Churns and ice cream machines are operated until steady conditions are established Other appliances supplied with rated voltage for a period as specified Winding temperatures not exceeding values specified in table 8 19 8 Three phase motors operated at rated voltage with one phase disconnected 19 9 Running overload test on appliances incorporating motors intended to be remotely or automatically controlled or liable to be operated continuously Winding temperatures not exceeding values as specified 19 10 Series motor operated at 1 3 times rated voltage for Mila lid During the test parts not being ejected from the appliance Test repeated with accessories in position but without additional load Coffee mills and grain grinders only tested for 30 s 19 101 Coffee mills and grain grinders are supplied at rated voltage and operated under normal operation five times with rest periods Duration of operating
59. lation P withstand electrical stress For coatings used on printed circuits boards to N A protect the microenvironment Type 1 or to provide basic insulation Type 2 annex J applies The microenvironment is pollution degree 1 under N A Type 1 coating No clearance or creepage distance requirements N A under Type 2 coating 29 1 Clearances not less than the values specified in P table 16 taking into account the rated impulse 28 4 voltage for the overvoltage categories of table 15 unless for basic insulation and functional insulation they N A comply with the implulse voltage test of clause 14 However if the construction is affected by wear N A distortion movement of the parts or during assembly the clearances for rated impulse voltages of 1500V and above are increased by 0 5 mm and the impulse voltage test is not applicable Impulse voltage test not applicable P when the microenvironment is pollution degree 3 P for basic insulation of class 0 and class 01 N A appliances Appliances are in overvoltage category II P Clearances less than specified in table 16 not N A allowed for basic insulation of class O and class Ol appliances or if pollution degree 3 is applicable P TRF No IEC60335_2_15E Page 51 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Clearances of basic insulation withstand the overvoltages taking into account the rated impulse voltage Clearanc
60. liance C Indicator label NINGBO FENGHUA KUNPENG LABEL CO LTD Plastic Chi Mei Corp enclosure PCB Pan An PCB Fty PFR 4 94V 0 EN 60 335 2 15 Test with Min thickness EN 60 335 2 14 appliance 1 5mm UL E199273 Alternative ZHEJIANG T TIANCHI ELECTRONICS CO LTD X2 capacitor Tenta Electric 0 1 u F 275VAC IEC 60384 14 VDE Industrial Co Ltd T100 119119 Alternative Carli Electronics 0 1 u F 275VAC IEC 60384 14 VDE Co Ltd T100 40008520 Fuse Cooper Bussmann S506 250V 10A EN 60127 1 VDE Inc 40011926 Alternative Sun Electric Co 5B series 250V 10A EN 60127 1 VDE O B Heroday Ltd 40011342 Alternative Dongguan Better 51 524 250V 10A EN 60127 1 VDE Electronic T10AH250V 40020107 Technology Co Ltd Closed end The Heavy Power Min thickness EN 60 335 2 15 Test with connector Industrial Co Ltd 2 0mm EN 60 335 2 14 appliance UL E113650 EN 60 335 2 15 Test with Min thickness 1 5 EN 60 335 2 14 appliance UL E255892 MEX MPX TRF No lEC60335_2 15E IEC 60335 2 15 Report No Page 76 of 110 130229 Requirement Test Result Remark Verdict Min thickness 1 2mm Alternative KAI SUH SUH ENTERPRISE CO LTD Hot water hose Hangyu Electronic Technology Co Ltd Cold water hose Hangyu Electronic Teflon tubing Min thickness Technology Co 2 45mm Ltd K D Function ZHEJIANG LEMA W 250V 3A R Silicon tubing Min thickness selection switch
61. liance is N A considered to be suitable for use in countries having a warm damp equable climate but may also be used in other countries 11 8 The values of Table 3 are reduced by 15 K Po N A Leakage current and electric strength at operating temperature N A 13 2 The leakage current for class appliances not N A exceeding 0 5 mA Leakage current and electric strength N A 16 2 The leakage current for class appliances not N A exceeding 0 5 mA Abnormal operation N A 19 13 The leakage current test of 16 2 is applied in addition N A to the electric strength test of 16 3 ANNEX Q INFORMATIVE SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS P Description of tests for appliances incorporating electronic circuits P ANNEX R NORMATIVE SOFTWARE EVALUATION Software evaluated in accordance with the following clauses of Annex H of IEC N A 60730 1 as modified Only definitions H 2 16 to H 2 20 applicable PNA Only footnotes 12 to 18 of Table 7 2 as modified N A applicable H 11 12 Controls using software N A All the subclauses of H 11 12 as modified except N A H 11 12 6 and H 11 12 6 1 applicable H 11 12 7 Delete text PNA 4 vy A Z m Q o a a a N _ a m Page 68 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict H 11 12 7 1 For appliances using software class C having a N A single channel with self test and monitoring structure the manufacturer provides
62. lt Remark Electric strength test of 16 3 voltage of 1000 V N A applied 22 17 Spacers not removable from the outside by hand or N A by means of a screwdriver or a spanner a Current carrying parts and other metal parts resistant P to corrosion under normal conditions of use y Driving belts not used as electrical insulation E N A Direct contact between live parts and thermal N A insulation effectively prevented unless material used is non corrosive non hygroscopic and non combustible Compliance is checked by inspection and if N A necessary by appropriate test Wood cotton silk ordinary paper and fibrous or N A hygroscopic material not used as insulation unless impregnated This requirement does not apply to magnesium P oxide and mineral ceramic fibres used for the electrical insulation of heating elements gt Appliances not containing asbestos Po P Oils containing polychlorinated biphenyl PCB not N A used Bare heating elements adequately supported Po In case of rupture the heating conductor is unlikely to come in contact with accessible metal parts Sagging heating conductors cannot come into contact with accessible metal parts The insulation between parts operating at safety extra low voltage and other live parts complies with the requirements for double or reinforced insulation Report No 130229 IEC 60335 2 15 N NIN N NIN N N NIN N NIN N N NIN N N gt gt E VIN o u 00 N A N A 2229
63. ltage 11 6 Combined appliances operated under normal N A operation at most unfavourable voltage between 0 94 and 1 06 times rated Voltage ccoiconcommm A 11 7 Tests carried out as specified i ified see appended tables P 11 8 Temperature rises not exceeding values in table 3 see appended tables P Protective devices do not operate N A Sealing compound does not flow out N A components in protective electronic circuits tested for the number of cycles specified in 24 1 4 IEC 60335 1 A1 2004 19 1 The risk of fire or mechanical damage under abnormal or careless operation obviated Test of 19 7 only applicable to berry juice extractors blenders for food centrifugal juicers churns food mixers food processors ice cream machines mincers and noodle makers N A Coffee mills and grain grinders subjected to the tests of 19 101 and to 19 102 unless they have to be kept switched on by hand Electronic circuits so designed and applied that a fault will not render the appliance unsafe Appliances incorporating contactors or relays subjected to the test of 19 14 being carried out before the tests of 19 11 IEC 60335 1 A2 2006 N A 19 7 Stalling test by locking the rotor if the locked rotor N A torque is smaller than the full load torque or locking moving parts of other appliances N A Locked rotor motor capacitors open circuited or short circuited if required N A N A Loc
64. ltage Creepage distance V mm Pollution degree EA ANA OP Materiat group Material group pT Te fwaw i f tere COI TRF No IEC60335_2 15E Page 81 of 110 N Nemko Report No 130229 IEC 60335 2 15 Requirement Test Result Remark op os fos aa aw EIC Wa somaa fos is 22 02 ao fas so NA sonas fis 32 fas sa eo 90 foo NA 250 ne lt i00 42 63 oo 125 160 ieo foo NA eoma lt 200 55 80 mo 180 200 220 fso NA osoo ana 000 aso e20 aso 680 ano ooo froo NA 30 1 1 TABLE Ball pressure Test temperature C Impression diameter Allowed impression DE diameter a Plastic enclosure enclosure TRF No lEC60335_2 15E Page 82 of 110 N Nemko Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict ernro f o o o o o o Bobbin of motor of water 125 0 4 2 0 pump ae oe at a Cartes merece restos o y e mmaa O o o mwa O o e e Fransson O wo O e l mwa o o y a e pos po pao w J e e emme O o f e e e S S S I v o o y a e coseteracomecer O o l a pump TRF No IEC60335_2_15E Page 83 of 110 MEA Report No 130229 Requirement Test Result Remark APPENDIX 1 EN group difference to IEC60335 1 and IEC 60335 2 15 GROUP DIFFERENCES to IEC 60335 1 4 ed Amendment A1 2004 Amendment A2 2006 aa Protection against electric shock Class 0 01 Class HEC 60335 4 Il Ill Rated voltage or voltag
65. m grinding switch terminal accessible part 9 4mm TABLE Creepage distances basic supplementary and reinforced insulation P Working voltage Creepage distance V mm Pollution degree AO O reia Material group Material group ae Pw fae O Pann a sae Vera a a or e bie fe Pie PETE a o Jor fos oo v2 as Jr 19 so pa re re a4 30 fo ss wa sevens fpa fos er 18 19 far ae na E ADA OE gt 50 and lt 125 gt 50 and lt 125 lt 125 CET AE AEA AE pt TRF No IEC60335_2_15E Page 79 of 110 MEA Report No 130229 IEC 60335 2 15 Requirement Test Result Remark MESES tes to 49 es ac 0 12 e ee AXE EEE 09 EC E gt 400 and lt 500 ae ESTERO e E ES gt 500 and lt 800 8 0 O IA IN maes 88 15 80 20 eo us 200 fell UE EPA AEREA EA EE EEE CASO EA E ETE EEE E E A EEE 2A E EAT IEA a Ne a 6 0 0 S 10 80 el lA EEES A sean 49 es 160 ES les Bra ll ANA EXEC EE CEM EA ES ETE ECM EE O A on 80 161 Me par Peer es le E ESTER ECO E E EEES EE E ES ESTE E EEN EEES Par A A ee eS Sl EXTERNA A EA ELN amarte 100128 180 250 60 680 860 88 A IM 0 eae ee 0 0 al A pa A A aaa A A o 0 OS p 0 SA EEE E A E EXPENSAS A E TRF No lEC60335_2 15E Page 80 of 110 N Nemko Report No 130229 IEC 60335 2 15 Requirement Test Result Remark ama Ja jas Jas 90 Jus Jas Jus Gore 00 E eo gt 4000 and lt s000 3
66. maximum power at low power points does not exceed 15 W according to the tests specified the protection against electric shock fire hazard mechanical hazard or dangerous malfunction in other parts of the appliance does not rely on the correct functioning of the electronic circuit Fault conditions applied one at a time the appliance operated under conditions specified in cl 11 but supplied at rated voltage the duration of the tests as specified a short circuit of functional insulation if clearances or creepage distances are less than the values specified in 29 b open circuit at the terminals of any component c short circuit of capacitors unless they comply with IEC 60384 14 d short circuit of any two terminals of an electronic component other than integrated circuits This fault condition is not applied between the two circuits of an optocoupler e failure of triacs in the diode mode f failure of an integrated circuit g failure of an electronic power switching device If the appliance incorporates a protective electronic circuit which operates to ensure compliance with clause 19 the relevant test is repeated with a single fault simulated as indicated in a to f of 19 11 2 During and after each test the following is checked the temperature rise of the windings do not exceed the values specified in table 8 the appliance complies with the conditions specified in 19 13 any current flowing through protec
67. may be provided to reduce pollution at the insulation by effective enclosures or similar Minimum clearances specified where pollution may be present in the microenvironment Degrees of pollution in the microenvironment For evaluating creepage distances the following degrees of pollution in the microenvironment are established pollution degree 1 no pollution or only dry non Sealing compound to protect conductive pollution occurs The pollution has no oxide magnetism against influence humidity Silicon tubing cover the seam pollution degree 3 conductive pollution occurs or dry non conductive pollution occurs that becomes conductive due to condensation that is to be expected pollution degree 4 the pollution generates persistent conductivity caused by conductive dust or by rain or snow ANNEX N NORMATIVE PROOF TRACKING TEST The proof tracking test is carried out in accordance __ Insulation enclosure cordless with IEC 60112 with the following modifications interface connection thermal cut out and PCB Test apparatus Test solutions TRF No IEC60335_2 15E pollution degree 2 only non conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be expected Page 66 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Determination of proof tracking index PTI The test is carried out on five specimens In case of doubt
68. ments see appended table 16 3 Electric strength tests according to table 7 see appended table No breakdown during the tests 17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS No excessive temperatures in transformer or N A associated circuits in event of short circuits likely to occur in normal use O 4 vy Z m Q o a a a N a m Page 18 of 110 Report No 130229 IEC 60335 2 15 Verdict Appliance supplied with 1 06 or 0 94 times rated voltage and the most unfavourable short circuit or overload likely to occur in normal use applied Temperature rise of insulation of the conductors of safety extra low voltage circuits not exceeding the relevant value specified in table 3 by more than 15 K however limits do not apply to fail safe transformers complying with sub clause 15 5 of IEC 61558 1 ENDURANCE This clause of part 1 is not applicable IEC 60335 2 15 ABNORMAL OPERATION The risk of fire or mechanical damage under abnormal or careless operation obviated Electronic circuits so designed and applied that a fault will not render the appliance unsafe Appliances incorporating contactors or relays subjected to the test of 19 14 being carried out before the tests of 19 11 Kettles are not subjected to the test of 19 2 IEC 60335 2 15 Kettles checked by 19 101 unless the appliance incorporates a non self resetting thermal cut out IEC 60335 2 15 Kettles compl
69. n a suitable compartment Appliance provided with a set of terminals and cable entries conduit entries knock outs or glands allowing connection of appropriate type of cable or conduit Introduction of conduit or cable does not reduce clearances or creepage distances below values specified in 29 Type Z attachment is allowed for egg boilers feeding bottle heaters yoghurt makers and stands of cordless kettles IEC 60335 2 15 polychloroprene sheathed at least 60245 IEC 57 cross linked polyvinyl chloride sheathed at least 60245 IEC 87 TRF No IEC60335_2 15E Page 41 of 110 Requirement Test Result Remark Polyvinyl chloride sheathed N A Not used if they are likely to touch metal parts having a temperature rise exceeding 75K during the test of Clause 11 light polyvinyl chloride sheathed cord at least N A 60227 IEC 52 appliances not exceeding 3 kg ordinary polyvinyl chloride sheathed cord at least HO5VV F P 60227 IEC 53 other appliances Heat resistant polyvinyl chloride sheathed N A Not used for type X attachment other than specially prepared cords Report No 130229 IEC 60335 2 15 Heat resistant light polyvinyl chloride sheathed cord N A at least 60227 IEC 56 appliances not exceeding heat resistant polyvinyl chloride sheathed cord N A 60227 IEC 57 other appliances Supply cord of livestock feed boilers shall be N A polychroroprene sheathed IEC 60335 2 15 Nominal c
70. ndex of at least 850 C according to IEC 60695 2 12 Glow wire test not carried out on small parts that N A comply with the needle flame test of Annex E or on small parts of material classified as V 0 or V 1 according to IEC 60695 11 10 Test as specified for an interposed shielding material eens N A Parts of non metallic material supporting current N A carrying connections and parts of non metallic material within a distance of N A 3mm subjected to glow wire test of IEC 60695 2 11 Po Test not carried out on material having a glow wire N A ignition temperature according to IEC 60695 2 13 of at least TRF No IEC60335_2 15E Page 56 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark AA a E o 775 C for connections carrying a current exceeding N A 0 2A during normal operation 675 C for other connections Po N A When the glow wire test of IEC 60695 2 11 is carried out the temperatures are N A 750 C for connections carrying a current exceeding N A 0 2A during normal operation 650 C for other connections PAN N A Parts that during the test produce a flame persisting N A longer than 2 s tested as specified If a flame persists longer than 2 s during the test N A parts above the connection as specified subjected to the needle flame test of annex E unless the material is classified as V 0 or V 1 according to N A IEC 60695 11 10 Le Base material of printed circuit boards
71. ng surface does not ignite 19 102 Test with one of the thermal cut outs rendered inoperative carried out 100 times Appliances with detachable liquid containers Only one detachable liquid automatic transfer of liquid from one container to container another is liable and safe One cycle operation with liquid container and pipes incorrectly positioned or removed Electric strength test No trace of water on insulation which can result in reduction of creapage distance and clearance below values specified in 29 1 Tilting test through an angle of 10 appliance placed on an inclined plane horizontal plane appliance does not overturn TRF No IEC60335_2 15E Page 25 of 110 Report No 130229 IEC 60335 2 15 Result Remark Verdict Possible heating test in overturned position temperature rise does not exceed values shown in table 9 Moving parts adequately arranged or enclosed as to Coffee mill tested in the provide protection against personal injury APPENDIX 4 Protective enclosures guards and similar parts are non detachable Adequate mechanical strength and fixing of protective enclosures Self resetting thermal cut outs and overcurrent protective devices not causing a hazard by unexpected reclosure Not possible to touch dangerous moving parts with test probe MECHANICAL STRENGTH Appliance has adequate mechanical strength and is constructed as to withstand rough handling Checked by applying blows t
72. nternal wiring sufficiently rigid and fixed N A 23 5 The insulation of internal wiring withstanding the P electrical stress likely to occur in normal use No breakdown when a voltage of 2000 V is applied P for 15 min between the conductor and metal foil wrapped around the insulation 23 6 Sleeving used as supplementary insulation on N A internal wiring retained in position by positive means 23 7 The colour combination green yellow used only for P earthing conductors Aluminium wires not used for internal wiring PEA P TRF No IEC60335_2_15E Page 36 of 110 Requirement Test Result Remark 23 9 No lead tin soldering of stranded conductors where P they are subject to contact pressure unless clamping means so constructed that there is no risk N A of bad contact due to cold flow of the solder The insulation and sheath of internal wiring N A incorporated in external hoses for the connection of an appliance to the water mains at least equivalent to that of light polyvinyl chloride sheathed flexible cord 60227 IEC 52 Report No 130229 IEC 60335 2 15 Components comply with safety requirements in P relevant IEC standards List of components see appended table P Components not tested and found to comply with relevant IEC standard for the number of cycles specified are tested in accordance with 24 1 1 to Components not tested and found to comply with relevant IEC standard components not marked or not used in accor
73. o the appliance in accordance with test Ehb of IEC 60068 2 75 spring hammer test impact energy 0 5 J If necessary supplementary or reinforced insulation subjected to the electric strength test of 16 3 If necessary repetition of groups of three blows on a new sample See Note IEC 60335 2 15 Accessible parts of solid insulation having strength to prevent penetration by sharp implements The insulation is tested as specified unless the thickness of supplementary insulation is at least Min thickness of enclosure 1 mm and reinforced insulation is at least 2 mm 2 9mm CONSTRUCTION Appliance marked with the first numeral of the IP system relevant requirements of IEC 60529 are fulfilled Stationary appliance means to provide all pole disconnection from the supply provided the following means being available TRF No IEC60335_2 15E Page 26 of 110 Requirement Test Result Remark a statement in the instruction sheet that a N A disconnection incorporated in the fixed wiring is to be provided an appliance inlet Singe pole switches and single pole protective devices for the disconnection of heating elements in single phase permanently connected class 01 and class appliances connected to the phase conductor Report No 130229 IEC 60335 2 15 N A N A Appliance provided with pins no undue strain on N A socket outlets Applied torque not exceeding 0 25 Nm Pull force of 50N to each pin
74. on having adequate thickness or a sufficient number of layers to withstand the electrical stresses Compliance checked by P TRF No IEC60335_2_15E Page 53 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark measurement in accordance with 29 3 1 or AN an electric strength test in accordance with 29 3 2 or an assessment of the thermal quality of the material combined with an electric strength test in accordance with 29 3 3 Supplementary insulation having a thickness of at least 1 mm Reinforced insulation having a thickness of at least 2 mm 29 Each layer of material withstand the electric strength test of 16 3 for supplementary insulation Supplementary insulation consisting of at least 2 layers Reinforced insulation consisting of at least 3 layers The insulation is subjected to the dry heat test Bb of IEC 60068 2 2 followed by the electric strength test of 16 3 If the temperature rise during the tests of Clause 19 does not exceed the value specified in Table 3 the test of IEC 60068 2 2 is not carried out RESISTANCE TO HEAT AND FIRE External parts of non metallic material parts supporting live parts and thermoplastic material providing supplementary or reinforced insulation 3 1 Loi 33 sufficiently resistant to heat Ball pressure test according to IEC 60695 10 2 External parts at 40 C plus the maximum see appended table tempera
75. operate except P components in protective electronic circuits tested for N A the number of cycles specified in 24 1 4 When an appliance connector incorporates a N A thermostat the temperature rise limit for the pins of the inlet does not apply IEC 60335 2 15 The temperature rise limits of motors transformers N A components of electronic circuit and parts directly influenced by them may be exceeded when the appliance is operated at 1 15 times rated power input IEC 60335 2 15 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE Leakage current not excessive and electric strength P adequate Heating appliances operated at 1 15 times rated N A power input Motor operated appliances and combined P appliances supplied at 1 06 times rated voltage Protective impedance and radio interference filters P disconnected before carrying out the tests Leakage current measured by means of the circuit P described in figure 4 of IEC 60990 Leakage current measurements see appended table The appliance is disconnected from the supply Electric strength tests according to table 4 see appended table No breakdown during the tests TRANSIENT OVERVOLTAGES TRF No IEC60335_2_15E Page 15 of 110 Requirement Test Result Remark Report No 130229 IEC 60335 2 15 Appliances withstand the transient overvoltages to N A which they may be subjected Clearances having a value less than specified in N A tabl
76. ow values specified in 29 2 Ceramic material not tightly sintered similar material or beads alone not used as supplementary or reinforced insulation Oxygen bomb test at 70 C for 96 h and 16 h at room temperature Insulating material in which heating conductors are embedded is considered to be basic insulation and not reinforced insulation Conductive liquids that are or may become accessible in normal use are not in direct contact For class Il constructions conductive liquids that are or may become accessible in normal use not in direct contact with basic or reinforced insulation TRF No IEC60335_2 15E Page 31 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict For class ll constructions conductive liquids which are in contact with live parts not in direct contact with reinforced insulation Shafts of operating knobs handles levers etc not live unless the shaft is not accessible when the part is removed Handles levers and knobs held or actuated in normal use not becoming live in the event of a failure of basic insulation Such parts being of metal and their shafts or fixings are likely to become live in the event of a failure of basic insulation are either adequately covered by insulation material or their accessible parts are separated from their shafts or fixings by supplementary insulation This requirement does not apply to handles levers and knobs on stat
77. period as specified in IEC 60335 2 14 Duration of rest period as specified in IEC 60335 2 14 Winding temperatures not exceeding values as specified in Table 8 Page 94 Report No 130229 Result Remark 1min 72 C lt 215 C oO N lt of 110 N A N A N A N A N A N A N A N A N A N A Requirement Test 19 102 Coffee mills and grain grinders subjected to the test as specified in IEC 60335 2 14 and carried out on three additional appliances If any of the motors stall original appliance subjected to the test of 19 7 20 2 Moving parts adequately arranged or enclosed as to provide protection against personal injury Protective enclosures guards and similar parts are non detachable Adequate mechanical strength and fixing of protective enclosures Self resetting thermal cut outs and overcurrent protective devices not causing a hazard by unexpected reclosure Not possible to touch dangerous moving parts with test probe Detachable accessories are removed and covers are opened except that for centrifugal juicers the cover and the container for collecting the residue are in position graters and shredders this is only applicable to accessories that are removed while the appliance is in operation Test probe not applied to appliances specified in the list the following parts of other appliances smooth shafts having a diameter not exceeding 8 mm
78. pervised not to play with the appliance Appliance with inlet and intended to be immersed for cleaning instruction sheet including in substance IEC 60335 2 15 7 remove connector before cleaning dry appliance inlet before re use The instructions for use for appliances intended to be used with a connector incorporating a thermostat shall state that only the appropriate connector must be used Unless kettles are constructed so that a hazard cannot arise from boiling water being ejected the instructions for use shall include the substance of the following if the kettle is overfilled boiling water may be ejected The instructions for use for kettles filled through a lid aperture which is situated below the handle shall include the substance of the following warnings Warning Position the lid so that steam is directed away from the handle TRF No IEC60335_2 15E E ES Page 8 of 110 Requirement Test Result Remark Verdict Warning Do not remove the lid while the water is N A boiling Cordless kettles N A the instructions for use for cordless kettles shall N A state that the kettle is only to be used with the stand provided if the kettle and stand of cordless kettles can be N A lifted together by gripping the handle of the kettle the instructions for use shall include the substance of the following Caution Ensure that the kettle is switched off before removing it from
79. probe B of IEC 61032 no contact with live parts Use of test probe 13 of IEC 61032 through openings in class 0 appliances and class II appliances constructions no contact with live parts TRF No IEC60335_2 15E Page 11 of 110 Requirement Test Result Remark Test probe 13 also applied through openings in N A earthed metal enclosures having a non conductive coating no contact with live parts See Note IEC 60335 2 15 Connecting device for coffee P mill is checked 8 1 3 For appliances other than class Il use of test probe N A 41 of IEC 61032 no contact with live parts of visible glowing heating elements Accessible part not considered live if N A Report No 130229 IEC 60335 2 15 safety extra low a c voltage peak value not N A exceeding 42 4 V safety extra low d c voltage not exceeding 42 4 V Po N A or separated from live parts by protective N A impedance If protective impedance d c current not exceeding N A 2 mA and a c peak value not exceeding 0 7 mA MA N A for peak values over 42 4 V up to and including N A 450 V capacitance not exceeding 0 1 uF A El for peak values over 15kV the energy in the N A discharge not exceeding 350 mJ Live parts protected at least by basic insulation before installation or assembly N A appliances delivered in separate units Ml N A Class ll appliances and constructions constructed so P that there is adequate protection against accidental con
80. r no risk of damage to the conductors when fitting the cover no contact with accessible metal parts if a conductor becomes loose etc For portable appliances the uninsulated end of a conductor prevented from any contact with accessible metal parts unless the end of the cord is such that the conductors are unlikely to slip free is not for cold conditions if temp rise of external metal parts exceeds 75 K unless the supply cord is not likely to touch such metal parts Interconnection cords comply with the requirements for the supply cord except as specified If necessary electric strength test of 16 3 Interconnection cords not detachable without the aid of a tool if compliance with the standard is impaired when they are disconnected Dimensions of pins compatible with the dimensions of the relevant socket outlet Dimensions of pins and engagement face in accordance with the relevant plug in IEC 60083 Supply cords of kettles shall not be longer than 75 cm unless they are helically coiled 1EC60335 2 15 If a cordless kettle has a cord storage facility the length of the cord is measured after storing as much of the cord as possible Appliances provided with terminals or equally effective devices for connection of external conductors TRF No lEC60335_2 15E Page 45 of 110 Requirement Test Result Remark Terminals only accessible after removal of a non P detachable cover However earthing terminals ma
81. re tested in combination N A with their motor under the conditions specified in Annex D For water valves containing live parts and that are N A incorporated in external hoses for connection of an appliance to the water mains the degree of protection declared for subclause 6 5 2 of IEC 60730 2 8 is IPX7 Self resetting thermal cut outs with the test of N A 19 101 are subjected to 3 000 cycles of operation IEC 60335 2 15 Appliance couplers complying with IEC 60320 1 Po N A However appliances classified higher than IPXO the N A appliance couplers complying with IEC 60320 2 3 Interconnection couplers complying with IEC 60320 N A 2 2 Appliance couplers incorporating thermostats N A thermal cut outs or fuses in the connectors shall comply with IEC 60320 1 IEC 60335 2 15 Not applicable to conditions as specified N A IEC 60335 2 15 TRF No IEC60335_2 15E Page 38 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Small lamp holders similar to E10 lampholders N A complying with IEC 60238 the requirements for E10 lampholders being applicable If the remote operation of the appliance is via a N A telecommunication network the relevant standard for the telecommunication interface circuitry in the appliance is IEC 62151 The relevant standard for thermal links is IEC 60691 Approved P Thermal links not complying with IEC 60691 are considered to be an intentionally weak pa
82. rk Verdict Supply cord 12 150 AAA Indicating label 19 48 19 5 o TABLE Components OP Object part No Manufacturer Type model Technical data Standard Mark s of trademark conformity Power plug Ningbo Qiaopu D03 250V 16A DIN VDE 0620 VDE Electric Co Ltd CEE 7 or IEC 40002872 884 Alternative Yongkang Dedong YDD 03 250V 16A DIN VDE 0620 VDE Wire Co Ltd CEE 7 or IEC 40023026 884 Alternative Ningbo Qiaopu 250V 13A BS 1363 1 1995 ASTA Electric Co Ltd A1 A2 A3 930 Power cord Ningbo Qiaopu HO5VV F 3X0 75 mm DIN VDE 0281 5 VDE Electric Co Ltd HD 21 136970 Alternative Yongkang Dedong HO5VV F 3X0 75 mm DIN VDE 0281 5 VDE Wire Co Ltd HD 21 40021638 Thermostat Therm O Disc 36TMH01130 250V 10A T220 EN 60 730 2 9 VDE Europe B V C 1E4 Cycles 40012575 Thermal link Therm O Disc G4A00240C 250V 10A EN 60 691 VDE Europe B V Tf 240 C 40017228 TRF No lEC60335_2 15E Page 74 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark Verdict Alternative Therm O Disc G4A01240C 250V 10A EN 60 691 VDE Europe B V Tf 240 C 40017228 Cordless YUEQING KSD 168 C 220 240V 13A EN 60 335 2 15 Test with interface system DEVELOPED EN 60 335 2 14 appliance ELECTRICAL EQUIPMENT CO LTD Heating element Hangyu Electronic 230V 1200W 230V 1200W EN 60 335 2 15 Test with Technology Co appliance Ltd Ningbo Jiayin JY
83. rking shall be in a language acceptable for the country where the equipment is to be used Mains plug If the equipment shall be used with a special mains plug which is not listed in the component list e g United Kingdom samples of the modified product must be subject to a test according to the relevant clauses of the product standard Other product properties Depending on the country where the equipment is to be used national deviations may be considered Samples of the modified product may be tested again according to relevant clauses of the product standard modified by national deviations TRF No IEC60335_2 15E Page 5 of 110 MEA Report No 130229 IEC 60335 2 15 Requirement Test Result Remark 5 GENERAL CONDITIONS FOR THE TESTS Tests performed according to cl 5 e g nature of supply sequence of testing etc 5 3 The test of 19 101 is made after other tests N A IEC 60335 2 15 ls CLASSIFICATION 6 1 Protection against electric shock Class P Class 0 Ol Il Ill e2 Protection against harmful ingress of water fa N A Wash boilers and livestock feed boilers shall be at N A least IPX3 IEC 60335 2 15 7 MARKING AND INSTRUCTIONS CE Rated voltage or voltage range V 220 240V P Rated power input W 1400W P Manufacturer s or responsible vendor s name P o trademark or identification mark Trademark HYC O Model or type reference HES120A P Symbol 5172 of IEC 60417 for Class
84. ross sectional area of supply cords Max 5 8A measured 0 75 P according to table 11 rated current A cross mm sectional area mm i Portable appliances having a rated current of up to N A 10 A may incorporate a supply cord having a nominal cross sectional area of 0 75 mm if the length is less than 2 m IEC 60335 2 15 Supply cord not in contact with sharp points or edges Green yellow core for earthing purposes in Class appliance Conductors of supply cords not consolidated by P lead tin soldering where they are subject to contact pressure unless clamping means so constructed that there is no risk N A of bad contacts due to cold flow of the solder Moulding the cord to part of the enclosure does not damage the insulation of the supply cord Inlet opening so shaped as to prevent damage to the supply cord N A TRF No IEC60335_2_15E Page 42 of 110 Requirement Test Result Remark Unless the enclosure at the inlet opening is of Insulation material N A insulation material a non detachable lining or bushing complying with 29 3 for supplementary insulation provided If unsheathed supply cord a similar additional N A bushing or lining is required unless 25 14 Supply cords adequately protected against N A excessive flexing P Flexing test N A applied force N N A Report No 130229 IEC 60335 2 15 number of flexings i N A The test does not result in N A P short circui
85. rotating at a speed not exceeding 1 500 rev min and driven by motors having an input not exceeding 200 W outlet sides of grating and shredding disks rotating at a speed not exceeding 1 500 rev min projections from the surface of grinding disks cones and similar parts having a height less than 4 mm Test probe not applied to feed openings having a throat with following dimensions a height of at least 100 mm measured from the upper edge of the cutting blade i Report No Result Remark Motor does not stall Page 95 of 110 130229 N A U U v N A N A N A N A N A N A N A N A N A N A N A N A Page 96 of 110 MEA Report No 130229 Requirement Test Result Remark N A an average of the maximum and minimum cross sectional dimensions of the feed opening that does not exceed 65 5 MM ste sessalisiocala lot Lacie N A a maximum cross sectional dimension of the feed opening that does not exceed 76 mm For blenders detachable parts except lids are not N A removed Test carried out with a test probe similar to that of test probe B of IEC 61032 but with circular stop face as specified 20 101 Accessories for cream whippers egg beaters and N A hand held food mixers have no knife edges unless a suitable guard prevents accidental contact with their rotating parts Hand held food mixer not possible to easily release
86. rt for the purposes of Clause 19 Relays other than motor starting relays tested as N A part of the appliance They are also tested in accordance with Clause 17 of IEC 60730 1 the number of operations in 24 1 4 selected according to the relay function in the appliance No switches or automatic controls in flexible cords No devices causing the protective device in the fixed wiring to operate in the event of a fault in the appliance No thermal cut outs that can be reset by soldering Switches intended for all pole disconnection of N A stationary appliances are directly connected to the supply terminals and having a contact separation in all poles providing full disconnection under overvoltage category III conditions N A Plugs and socket outlets for extra low voltage N A circuits and heating elements not interchangeable with plugs and socket outlets listed in IEC 60083 or IEC 60906 1 or with connectors and appliance inlets complying with the standard sheets of IEC 60320 1 See note IEC 60335 2 15 N A Capacitors in auxiliary windings of motors marked N A with their rated voltage and capacitance and used accordingly TRF No IEC60335_2 15E Page 39 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Voltage across capacitors in series with a motor winding does not exceed 1 1 times rated voltage when the appliance is supplied at 1 1 times rated voltage under minimum
87. ructed so that there is no spillage of water or sudden jets of steam or hot water A1 2005 When removing the filling cap of the pressurized N A reservoir before the cap is removed completely the pressure shall be relieved in a controlled manner A1 2005 Compliance is checked by inspection during the test N A A1 2005 23 INTERNAL WIRING E O 2 TRF No IEC60335_2_15E Page 35 of 110 Requirement Test Result Remark Report No 130229 IEC 60335 2 15 Wireways smooth and free from sharp edges AAN P Wires protected against contact with burrs cooling P fins etc Wire holes in metal well rounded or provided with N A bushings Wiring effectively prevented from coming into contact N A with moving parts Beads etc on live wires cannot change their N A position and are not resting on sharp edges or corners Beads inside flexible metal conduits contained within N A an insulating sleeve 23 3 Electrical connections and internal conductors N A movable relatively to each other not exposed to undue stress Flexible metallic tubes not causing damage to N A insulation of conductors Adequate insulating lining provided inside a coiled N A spring the turns of which touch one another No damage after 10 000 flexings for conductors N A flexed during normal use or 100 flexings for conductors flexed during user maintenance Electric strength test 1000 V between live parts and N A accessible metal parts Bare i
88. setting and visual indication not necessary on appliances that can operate as N A follows without giving rise to a hazard 22 52 Socket outlets on appliances accessible to the user N A in accordance with the socket outlet system used in the country in which the appliance is sold 22 101 Kettles shall be constructed so that the lid does not N A fall off when water is poured out Kettles so constructed that there are no sudden jets N A of steam or hot water likely to expose the user to a hazard when the appliance is used as in normal Report No 130229 IEC 60335 2 15 Appliance coupler of cordless kettles shall be Connecting device for coffee P constructed to withstand the stresses occurring mill is checked during normal use P The kettle is inserted into and withdrawn from the 0 39A the rated current for P stand 10 000 times 1 1 times the rated current coffee mill is 0 35A at 240V 10 times per min The test is continued for a further 10 000 times Connecting device for coffee P without current flowing mill is checked The kettle shall be fit for further use and Connecting device for coffee P compliance with 8 1 16 3 27 5 and 29 1 shall not mill is checked be impaired Portable appliance in which water boil with a N A container greater than 3 is filled to its rated capacity with the lid closed in accordance with instructions for The plane is slowly inclined to an angle of 25 if the N A appliance overturns it is le
89. subjected to fast transient bursts in P accordance with IEC 61000 4 4 test level 3 or 4 as specified 19 11 44 The power supply terminals of the appliance P subjected to voltage surges in accordance with IEC 61000 4 5 test level 3 or 4 as specified Earthed heating elements in class appliances P disconnected 19 11 4 5 The appliance is subjected to injected currents in P accordance with IEC 61000 4 6 test level 3 19 11 4 6 The appliance is subjected to the Class 3 voltage P dips and interruptions in accordance with IEC 61000 4 11 TRF No IEC60335_2_15E Page 23 of 110 Report No 130229 MEA IEC 60335 2 15 Requirement Test Result Remark 19 11 4 7 The appliance is subjected to mains signals in accordance with IEC 61000 4 13 test level class 2 19 11 48 The appliance is supplied at rated voltage and operated under normal operation After 60s the power supply is reduces to a level such that the appliance ceases to respond or a programmable component cease to operate The appliance continues to operate normally or requires a manual operation to restart If the safety of the appliance for any of the fault gt 30A 10A conditions specified in 19 11 2 depends on the operation of a miniature fuse link complying with IEC 60127 the test is repeated measuring the current flowing through the fuse link measured current A rated current of the fuse link A i 19 13 During the tests the appliance does not emit flames
90. t specified in the instructions the brewing period is the time necessary to produce 100 ml of coffee for each cycle Page 90 of 110 MEA Report No 130229 Requirement Test Result Remark Replace the existing second paragraph by the following For espresso coffee makers having an outlet for supplying steam or hot water the brewing period is immediately followed by a period during which the steam or water is supplied for the time stated in the instructions or for the following periods whichever is more unfavourable for espresso coffee makers having an outlet for supplying steam 1 min for espresso coffee makers having an outlet for supplying hot water the time necessary to produce 100 ml of water Add the following to the addition For coffee makers provided with a removable coffee pot the liquid container is filled with maximum amount of water containing 1 NaCl The funnel is placed in position but without placing the coffee pot in position The appliance is switched on and operated until the container is empty Add the following to the modification For rice cookers the test specified in Part 1 shall be conducted with the rice container in place The interior of rice cookers shall not be affected by water Compliance is checked by the following test The rice cooker is placed on a horizontal surface with the rice container removed and 30 ml of water containing approximatel
91. t No 130229 IEC 60335 2 15 Requirement Test Result Remark Verdict Terminals for type X attachment except those with a specially prepared cord and those for connection to fixed wiring no special preparation of conductors required and so constructed or placed that conductors prevented from slipping out Terminals for type X attachment so located or shielded that if a wire of a stranded conductor escapes no risk of accidental connection to other parts that result in a hazard No contact between live parts and accessible metal parts and for class II constructions between live parts and metal parts separated from accessible metal parts by supplementary insulation only Terminals for type X attachment and for connection to fixed wiring suitable for connection of conductors with required cross sectional area according to table 13 rated current A nominal cross sectional area mm Terminals only suitable for a specially prepared cord Terminals for type X attachment accessible after removal of a cover or part of the enclosure Terminals for the connection to fixed wiring including the earthing terminal located close to each other Terminals of the pillar type constructed and located as specified Terminals with screw clamping and screwless terminals not used for flat twin tinsel cords unless conductors ends fitted with a device suitable for screw terminals For type Y and Z attachment soldered welded crimpe
92. t between the conductors Ee N A breakage of more than 10 of the strands of any N A conductor separation of the conductor from its terminal a N A damage within the meaning of the standard to the N A cord or the cord guard broken strands piercing the insulation and becoming accessible Conductors of the supply cord relieved from strain twisting and abrasion by use of cord anchorage N A The cord cannot be pushed into the appliance to such an extent that the cord or internal parts of the appliance can be damaged Pull and torque test of supply cord values shown in 100N 0 35Nm P table 10 pull N torque not on automatic cord reel Max 2 mm displacement of the cord and P conductors not moved more than 1 mm in the terminals TRF No lEC60335_2 15E Page 43 of 110 Requirement Test Result Remark 25 16 Cord anchorages for type X attachments constructed and located so that N A replacement of the cord is easily possible N A it is clear how the relief from strain and the N A prevention of twisting are obtained they are suitable for different types of cord N A cord cannot touch the clamping screws of cord N A anchorage if these screws are accessible unless separated from accessible metal parts by supplementary insulation the cord is not clamped by a metal screw which bears directly on the cord at least one part of the cord anchorage securely fixed to the appliance unless p
93. t of all group differences and national deviations to IEC60335 1 and IEC 60335 2 15 APPENDIX 2 includes the test result of EMF APPENDIX 3 includes the assessment according to EN 60335 2 15 2002 A2 2008 APPENDIX 4 includes the assessment according to EN 60335 2 14 2006 A1 2008 APPENDIX 5 Photos Document TRF No IEC60335_2 15E Page 4 of 110 Test item particulars oooooooconnninnonnnnncnnconcocnccnncnos Coffee Maker Report No 130229 Classification of installation and US cccoccncnnn Portable appliance Supply COMNECHON sarna diodo Supply cord with plug Possible test case verdicts test case does not apply to the test object N A test object does meet the requirement test object does not meet the requirement Date of receipt of test item oooooonoccnnnccinnccinnccnncccncaccnnns 2009 09 01 Date s of performance of tests 2008 09 02 to 2009 11 03 General remarks The test results presented in this report relate only to the object tested This report shall not be reproduced except in full without the written approval of the Issuing testing laboratory See Enclosure refers to additional information appended to the report See appended table refers to a table appended to the report Throughout this report a comma is used as the decimal separator General product information Marking label user manual packing text Instructions and ma
94. tact with basic insulation and metal parts separated from live parts by basic insulation only Only possible to touch parts separated from live P parts by double or reinforced insulation STARTING OF MOTOR OPERATED APPLIANCES for peak values over 450 V up to and including 15 kV discharge not exceeding 45 uC TRF No IEC60335_2_15E Page 12 of 110 Requirement Test Result Remark This clause of part 1 is not applicable N A IEC 60335 2 15 POWER INPUT AND CURRENT 10 1 Power input at normal operating temperature rated See appended table P voltage and normal operation not deviating from rated power input by more than shown in table 1 Test for an appliance with one or more rated voltage P ranges 10 2 Current at normal operating temperature rated N A voltage and normal operation not deviating from rated current by more than shown in table 2 Test for an appliance with one or more rated voltage N A ranges mo em HEATING 11 1 No excessive temperatures in normal use Coffee mill tested in the P APPENDIX 4 Placing and mounting of appliance as described PA P Portable appliances are tested away from the walls P of the test corner IEC 60335 2 15 Report No 130229 IEC 60335 2 15 11 Temperature rises other than of windings P determined by thermocouples Temperature rises of windings determined by N A resistance method unless the windings makes it difficult to make the necessary The winding of
95. the measures necessary to address the fault errors in safety related segments and data H 11 12 8 Software fault error detection occurs before N A compliance with 19 13 of IEC 60335 1 is impaired H 11 12 8 1 Replace text N A H 11 12 13 Software and safety related hardware under its N A control initializes and terminates before compliance with 19 13 of IEC 60335 1 is impaired TRF No IEC60335_2 15E Page 69 of 110 Report No 130229 N Nemko IEC 60335 2 15 Requirement Test Result Remark TABLE Power input deviation oP TABLE Current deviation TABLE Heating test thermocouples separately test at brewing and grinding function Test voltage Venid india Ambient CS II E ima wre comete o pea semen O wood spot TRF No IEC60335_2 15E Page 70 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Indicating label For clause 30 1 Cordless interface connection For clause 30 1 30 60 Knob Winding of motor of water pump 80 class 120 Bobbin of the motor of water pump For clause 30 1 re TABLE Heating iest restan mate po sw s IE class 3 CEI e FS Heating appliances 1 15 x rated input NA mz Motor operated and combined appliances gt n 1 06 x rated VONAGE iivcsciisscecsacieehstetusdirdeasasins Leakage current between Max allowed I mA Live part and accessible parts over basic insulation
96. tive impedance not exceeding the limits specified in 8 1 4 If a conductor of a printed board becomes open circuited the appliance is considered to have withstood the particular test provided all three of the following conditions are met TRF No IEC60335_2 15E Page 22 of 110 Requirement Test Result Remark the material of the printed circuit board withstands N A the burning test of annex E any loosened conductor does not reduce the N A clearances or creepage distances between live parts and accessible metal parts below the values specified in cl 29 the appliance withstands the tests of 19 11 2 with N A open circuited conductor bridged Report No 130229 IEC 60335 2 15 19 11 4 Appliances having a device with an off position P obtained by electronic disconnection or a device that can be placed in the stand by mode EA N A subjected to the tests of 19 11 4 1 to 19 11 4 7 Not possible unsafe operation P Appliances incorporating a protective electronic N A circuit subjected to the tests of 19 11 4 1 to 19 11 4 7 except that appliances operated for 30 s or 5 min during the test N A of 19 7 are not subjected to the tests for electromagnetic phenomena 19 11 41 The appliance is subjected to electrostatic P discharges in accordance with IEC 61000 4 2 test level 4 19 11 42 The appliance is subjected to radiated fields in P accordance with IEC 61000 4 3 test level 3 19 11 4 3 The appliance is
97. ture rise determined during the test of clause 11 or at 75 C whichever is the higher temperatur Parts supporting live parts at 40 C plus the see appended table maximum temperature rise determined during the test of clause 11 or at 125 C whichever is the higher temperature C TRF No IEC60335_2 15E Page 54 of 110 Report No 130229 IEC 60335 2 15 Requirement Test Result Remark Parts of thermoplastic material providing see appended table supplementary or reinforced insulation 25 C plus the maximum temperature rise determined during clause 19 if higher temperature C For coffee makers egg boilers steam cookers and kettles the temperature rises occurring during the tests of 19 4 19 5 and 19 101 are not taken into account IEC 60335 2 15 Parts of non metallic material adequately resistant to ignition and spread of fire This requirement does not apply to decorative trims knobs and other parts unlikely to be ignited or to propagate flames that originate inside the appliance In addition For water distillers and appliances intended to maintain liquid of food at a particular temperature 30 2 3 applies IEC 60335 2 15 Glow wire test of IEC 60695 2 11 at 550 C unless the material is classified at least HB40 according to IEC 60695 11 10 Parts for which the glow wire test cannot be carried out meet the requirements in ISO9772 for category HBF material For other applianc
98. ure Chi Mei Corp sl thickness 2 0 EN 60 335 2 14 Test with appliance Interlock switch YUEQING DONG KW10 250V 3 0 5 A T55 EN 61058 1 TUV NAN 10000 operations R ELECTRONIC CO 50060067 LTD An asterisk indicates a mark which assures the agreed level of surveillance 28 1 1 TABLE Threaded part torque test CI part identification Diameter of thread Column number Applied torque Em Nm mm E N II or 111 TABLE Clearances Type of insulation a me Min cl Basic Functional Supplementary Reinforced Remark voltage V mm D A CO E IE eh O ARE TR Cw for O asco fos ii IES aseo ass 10000 som stmm o aos fae Cid am CS TRF No IEC60335_2 15E Page 78 of 110 N Nemko Report No 130229 IEC 60335 2 15 Requirement Test Result Remark sooo ss a IC E ff O O E The value is increased to 0 8mm for pollution degree 3 If the construction is affected by wear distortion movement of the parts or during assembly the value is increased by 0 5 mm 0 L N earthing terminal within the cordless interface connection 4 2mm End of heating elements earthing metal 1 8mm gt 1 0mm limit winding of motor metal core 3 5mm commutator motor axis 2 9mm 2 L N within the cordless interface connection 3 5mm L N on PCB 6 0mm Internal wiring accessible parts 5 0mm Live parts in the cordless interface connection accessible surface 14 0m
99. usher that fills the throat of the hopper is N A provided 20 107 Slicing machines other than fixed appliances and N A those having a biased off switch incorporate means to hold the appliance in place and allow it to be released after use no move on glass plate when subjected to test as specified 20 108 slicing machines NA provided with a guard surrounding the knife and its N A edge guard opening as small as permitted by effective N A use edge of knife guarded as shown in Fig 101 Po N A or 90 if compliance with required condition N A fulfilled radial distance a mm 2mm b 0 or N A 3mm edge of the knife protected from the outlet side N A relevant distances mm 6mm and 5mm respectively additional guard provided if slices thicker than N A 15mm allowed sliding feed table adequately designed f_30mm N A d 5mm thumb guard projects radially by at least 8mm beyond the blades piece holder enables small pieces to be sliced Po N A dimensions of spikes or similar as specified Po N A support of sliding table not usable for supplying N A food without the table in position verified dash Nos 20 109 Slicing machines constructed so that accidental N A operation of the appliance is prevented Actuating member of push button toggle rocker or N A slide switch recessed and actuated with force at least 2N Page 98 of 110 MEA Report No 130229 Requirement Test Result Remark N A Actu
100. y 1 NaCl is poured on to the centre of the bottom of the interior of the rice cooker The saline solution is poured steadily through a tube having an inner diameter of 8 mm and a length of 30 mm over a period of 2 s the lower end of the tube being 200 mm above the bottom of the rice cooker The rice cooker shall then withstand the electric strength test of 16 3 Add the following Induction rice cookers are operated under the conditions of Clause 11 with the rice container empty Page 91 of 110 N Nemko Report No 130229 Requirement Test Result Remark Add the following The temperature rise of the windings of induction rice cookers shall not exceed the values specified in 19 7 The electric strength test of induction rice cookers is carried out immediately after switching off the appliance Page 92 of 110 N Nemko Report No 130229 Requirement Test Result Remark APPENDIX 4 The assessment according to EN 60335 2 14 2006 A1 2008 Hand held kitchen machines shall be class II or class Ill EN 60335 2 14 2006 7 12 Instructions shall include the operating times and No accessories N A speed settings for accessories Adequate instruction for use for slicing machines N A provided with a base having a plain surface underneath the sliding feed table The instructions for food processors shall warn N A against misuse Instructions for hand held blenders Po N A always disconne
101. y be accessible if a N A tool is required to make the connections and means are provided to clamp the wire independently from its connection Report No 130229 IEC 60335 2 15 Appliances with type X attachment and appliances N A for connection to fixed wiring provided with terminals in which connections are made by means of screws nuts or similar devices unless the connections are soldered N A internal conductors if so arranged that they are N A unlikely to be displaced when fitting the supply conductors If soldered connections used the conductor so N A positioned or fixed that reliance is not placed on soldering alone Soldering alone used barriers provided clearances N A and creepage distances satisfactory if the conductor becomes free at the soldered joint Terminals for type X attachment and for connection N A to fixed wiring so constructed that the conductor is clamped between metal surfaces with sufficient contact pressure and without damaging the conductor N A the terminal does not loosen N A internal wiring is not subjected to stress N A clearances and creepage distances are not N A reduced below the values in 29 Compliance checked by inspection and by the test of N A subclause 9 6 of IEC 60999 1 the torque applied being equal to two thirds of the torque specified Nominal diameter of thread mm screw category torque Nm TRF No lEC60335_2 15E Page 46 of 110 Repor

Download Pdf Manuals

image

Related Search

Page page six paget\u0027s disease pagemaker pageant of the masters page vault page 6 page file settings paget brewster pagefile setting page maker o7 page arizona pagerduty login pagespeed insights pageant of the masters 2025 pages to pdf page of cups pages to word page six gossip today page six news pagefile page of swords pagepilot pagefly page insights page not found

Related Contents

WorkZone Explorer - User's Guide  User manual 738373  MUNDO 21 SPEED - Ashland Electric Bikes  Speco Technologies VM-1401C User's Manual    Brodit ProClip 854873  KIRK 3040 for KIRK Wireless Server 1500 and 500 User's Guide  Kenwood DDX7039M User's Manual  あんしんファミリーケータイに関する重要事項説明書(兼  anios quick wipes  