User Manual WAGO DALI and power measurement

image

Contents

1. 750493 WG750602 WG750613 WG750600 WG750628 WG750627 Sub D Connection plug 51x65 x 100 mm WG750315 4 myGEKKO This section covers the electrical connection of the bus coupler at the myGEKKO Touch For technical characteristics of the individual WAGO components and their maximum equipment see WAGO prod uct catalogue on www my gekko com AY HHH NAAA CoH A 0 B 1 to 4 maximum of 4 bus couplers on one port ANNA Connection of bus line RS485 on the bus coupler via included ProfiBus connector Caution Activation of the terminating resistor on the bus coupler at the and of the bus line RS485 GND screen RS485_ TX green A1 RS485_ TX red B1 myGEKKO 5 Connection at myGEKKO Connection at myGEKKO RS485 COM Port 2 PIN SIGNAL RS485_GND RS485_TX B RS485_ TX A V 10 32V V_GND CON AUN Fieldbus connection D Sub Address Address Configuration ene pregcamming interface Recommonend cabletype Profibus L2FIP 1x2x0 65 a 4 ma HN se On the ProfiBus connector of the bus coupler to further bus couplers max 4 pcs Status voltage supply Power jumper contacts System Data contacts Supply 24V OV Supply via power jumper contacts 24V OV ile Power jumper contacts 6 myGEKKO 1 2 MODBUS TCP IP The bus coupler is used as head of the following terminal blocks input output modules It represents the communication
2. ORT 1 4 MODBUS TCP IP 750 352 750 841 RS485 MODBUS RTU 750 315 750 815 It is possible to combine RIO bus couplers and WAGO bus couplers on the bus line 8 myGEKKO 1 4 Numbering of connections The numbering of in and outputs has to take place in order of the attached modules Generally it can be distinguished between 4 groups Digital outputs digital inputs analogue outputs analogue inputs The numbering of each group starts with 1 The inputs and outputs are numbered subsequently from left to right for each module The numbering is used in the parameterisation of the myGEKKO display controller to assign an input or output to the corresponding function The collocation of the modules at the bus coupler has to take place as follows e DI DO digital inputs digital outputs e DALI MODUL DALI interfaces if present e Al AO analogue inputs analogue outputs e POWERTERMINAL Power measurement terminals if present Caution The numbering of the inputs and outputs has to be made according to the adjacent drawing and not according to the numbers attached on the front of the modules This correct numbering can also be seen on the side of the modules and not on the front Digital outputs Digital inputs 34 gol e A th ie If a second bus coupler ACC STA01 is connected to the myGEKKO Touch the numbering at this cou pler starts anew The distinction between the first and the second bus cou
3. ed to the terminal E g for a 100 5A current transformer enter 20 as value 4 Now all current voltage consumption and output values should be visible If they are wrong or some show negative currents or consumption check the electrical connection of the cur rent transformers etc 5 Done Now you can use the individual outputs in the load shedding control or in the energy meters IO Configuration IO Configuration IOStation 2 OStation 3 OStation 4 IOStation 5 OStation 6 IOStation 7 Sinterface Configuration level of the power measurement Example Utilisation Sum of outputs in energy meter myGEKKO E 3 Notes 14 myGEKKO myGEKKO 15 my GEKKO www my gekko com A first class product of Europe The result of a close collaboration between Italy Switzerland and Germany
4. ights tap Extend 4 Show addressed lights Tap Show Now as many addresses should light up green on the numeric keypad 1 64 as ballasts are connected If the addresses are not displayed correctly wait a minute and repeat the process Show If the number still does not match e g one light may not be connected or addresses are assigned twice 5 Searching for addressed lights If not already select all lights found and tap Off All lights will switch off Now select light nr 1 and tap Flashing or On Search for the light and make a note of its address Proceed with lamp nr 2 3 6 Group assignment If you want to use group assignment select the light addresses you want to combine into a group Tap Set parameter There you can set several parameters for the light including the group assignment 7 Read parameters If you like to receive information about the parameters of the ballast select the corresponding light ad dress an tap Read parameters myGEKKO 11 8 Replace delete reassign addresses If you want to reassign replace or delete an address select the corresponding light address and tap the appropriate command Caution The large button Readdress on top of the configuration window assigns new addresses to ALL lights 9 Completion of the configuration Tap the back button and you will return to the I O configuration The Config button next to number of DALI and next to g
5. interface between the terminal blocks and the myGEKKO Touch The master mod ule is connected to the myGEKKO Touch with a myGEKKO Ethernet interface WAGO 750 315 Technical data Total current for bus coupler 700 mA at 5V Bus coupler connection 2 x RJ 45 Transmission medium Twisted Pair S UTP 100 O Cat 5 100 m max clable lengh Max number of bus coupler per myGEKKO Touch 8 Max number of terminal blocks to an bus coupler 64 Max number of digital inputs per bus coupler 256 Max number of digital outputs per bus coupler 256 Max number of analogue inputs per bus coupler 64 Max number of analogue outputs per bus cou 64 pler Max number of DALI Modules per bus coupler 4 Max number of POWER Modules per bus coupler 4 Compatible terminals WG750530 WG750523 WG750430 WG750559 WG750468 WG750455 WG750453 WG750460 WG750460 3 WG750641 WG750493 WG750602 WG750613 WG750600 WG750628 WG750627 Dimensions WxHxD 50 x 65 x 97 mm Article WG750352 myGEKKO 7 Labeling field IP Adress Ein 68 1 X voltage supply 0 WBM Power jumper contacts 255 DHCP System Data contacts Supply 24V OV Fieldbus connection RJ 45 Fieldbus connection RJ 45 Configuration and programming interface flap open idem for 750 841 1 3 Utilisation of several bus couplers A maximum of 4 bus lines can be operated on one Touch The bus couplers can be connected directly to the Touch COM Port 2 by default or via USB Port USB COM P
6. myaEKKO MAGO INNOVATIVE CONNECTIONS User Manual WAGO DALI and power measurement terminal V 0 2 mp GEKKO 9 Latest Update April 2013 All software related descriptions refer to the C2021 software An update is recommended for older versions of the system Small deviations of the descriptions are possible and due to changes in the software All brands and logos are registered trademarks and are the property of the respective holders of the rights Copyright All rights reserved No parts of this document may be reproduced or transmitted in any form by any means electronic or mechanical without the prior written authorization of its legal owner If this publication is made available on Ekon GmbH media Ekon gives its consent to downloading and printing copies of the content provided in this file only for private use and not for redistribution No part of this publication may be modified altered or used for commercial purposes Ekon GmbH is not liable for the damages which arise from the use of an illegal modified or altered publication CE All products correspond to the directly applicable EU regulations and guidelines 2 myGEKKO Table of Contents 1 Electrical connection and addressing cccccccccccccccceccccesceccssceces 4 LT R3483 MODBUS RIU rare near ner ea menor ee Eee 4 1 2 MODBUS TGF IP aia rias 7 1 3 Utilisation of several DUS couplers ccacocccascncrseensebachantediasvsearageseneeeeecses
7. onfiguration Wago 31x COM Port 2 lOStation 7 lOStation 8 Exemplary configuration of the Wago MODBUS RTU Single address gt gt Cong o eno IO Configuration Modbus COM Port 2 192 168 2 103 Exemplary configuration of the Wago MODBUS TCP IT 10 myGEKKO 2 2 DALI configuration You need to be logged in as configurator and have to have completed the main configuration ex plained in the previous section Change again to main settings gt I O configuration a 1 Individual or group addressing Select between individual and group addressing next to number of DALI When using individual ad dressing you can address each ballast individually max 64 for each DALI line When using group ad dressing groups can be operated max 16 for each DALI line Group addressing should be selected if more ballasts are attached to one lighting circle This has the advantage that all lights attached to the lighting circle switch simultaneously When using individual addressing the lights switch consecutively staggered When using group addressing only 16 lighting circles or groups per DALI line are possible 2 Configuration Tap gt gt and select the DALI line you want to configure 3 Addressing lights Tap Lamps to address the lamps If you have not addressed any lights yet tap Rescan and wait until the lower work display stops moving If you have already addressed lights and want to extend the line to more l
8. pler is set during the param eterisation If a terminal bus extension WG750627 WG750628 is used the numbering continues on the severed part myGEKKO 9 2 Software activation at myGEKKO 2 1 Main configuration You must be logged in as configurator 1 Change to main settings gt lO configuration av 2 RS485 MODBUS RTU Under IO Station 1 select WAGO 31x Define the port on which the bus coupler is connected usually COM Port 2 MODBUS TCP IP Under IO Station 1 select Modbus and as port choose LAN TCP Enter the IP address of the Wago Ethernet coupler in the right field If you use several bus couplers they need to be registered at station 2 3 or 4 according to the bus coupler addressing 3 Specify how many terminals you have connected DALI Specification of the connected DALI terminals on the bus coupler max 4 pcs Number DI Specification of the connected digital inputs Number must be greater than the modules installed E g when using 1 module 750 430 with 8 digital inputs 1x16 has to be selected Number DO Same as ID Number Al Number of analogue inputs This number must correspond to the number of analogue inputs installed E g when using only one module 750 460 4 has to be filled in Number AO Sameas Al PWR KI Number of power measurement terminals max 4 pcs 4 Done The WAGO inputs and outputs can now be used in the individual system menus O C
9. sens ees 8 1 4 Numbering of connections ee se seem ei es 9 2 Software activation at myGEKKO ooooooooomooocooomcocccccsoccosso 10 21 ial CORSO a 9948 a aa a re ea 10 2 2 DALI configuration Eee ee near aa 11 2 3 Power measurement terminal o ooooocoocoronnccnncco naco rr rr 13 SENDER a ee ee re Eee niert 14 myGEKKO 3 1 Electrical connection and addressing 1 1 RS485 MODBUS RTU The bus coupler is used as head of the following terminal blocks input output modules It represents the communication interface between the terminal blocks and the myGEKKO Touch The master mod ule is connected to the myGEKKO Touch by means of a myGEKKO RS485 interface WAGO 750 315 Technical data Total current for bus coupler Bus coupler connection Transmission medium Max number of bus coupler per myGEKKO Touch Max number of terminal blocks to bus coupler Max number of digital inputs per bus coupler Max number of digital outputs per bus coupler Max number of analogue inputs per bus coupler Max number of analogue outputs per bus cou pler Max number of DALI Modules per bus coupler Max number of POWER Modules per bus coupler Combatible terminals Included in the delivery Dimensions W x HxD Article 1650 mA at 5V 1 x D Sub 9 jack shielded Cu cable 2 4 x0 25 mm A 64 256 256 64 64 A A WG750530 WG750523 WG750430 WG750559 WG750468 WG750455 WG750453 WG750460 WG750460 3 WG750641 WG
10. t gt will light up red This means that the system is still in the configuration mode Tap the button briefly and it will light up green Now you can use the DALI addresses for the lighting circle assignment milf EU UN IN Lanfinratinn myG KKO IO Configuration Configuration Test IOStation 1 Groups Lights Commands g Readdress nde et wueno o een Show Number Al Number AO Readdr Blink Delete Replace Get parameter He Set parameter Dali Lamp ily 7 IO Configuration Station oe ao aa Di o Central button On Central button Off ILO San ies DIO Button dim Sf fe fe fs e Pe fo fo nbz s e i oo il Dim Out 1 R 0 Dali Group 1 R Yes Dim Out 2 G AO 0 fogo Dali Group 2 G QUO Assigned DALI address in the lighting Assignment of the DALI address at the lighting circle with group addressing 1 16 12 myGEKKO 2 3 Power measurement terminal You need to be logged in as configurator and have to have completed the main configuration ex plained in the previous section Change again to main settings gt I O configuration 1 Tap gt gt next to number of PWR terminals and you get to the configuration level of the power measurement terminals 2 Select Terminal 1 and tap Configure This step needs only be done once for each terminal 1 4 3 Define the current transformer ratio of the current transformers connect