User manual METTLER TOLEDO Weighing terminal IND429

image

Contents

1. After it has been connected the device carries out a self testing routine The device is ready to operate when the zero display appears Devices with built in or external storage battery The operating life depends on the intensity of use the configuration and the connected scale For details see Section 6 1 2 The battery symbol shows the current charge state of the storage battery segment corresponds to approx 2596 capacity If the symbol flashes the storage battery has to be charged If work is continued during the charging process the charging time is extended The storage battery is protected against overcharging The charging time of the storage battery amounts to approx 6 hours If the device continues to be operated during the charging process the charging time is extended The storage battery has a service life of approx 1 000 charging discharging cycles CAUTION Explosion hazard A In the case of explosion protected devices the storage battery may only be charged in a safe area CAUTION Danger of soiling The charger for the storage battery is not protected to IP69K A Do not charge the device in humid or dusty rooms A After the internal storage battery has been charged close the cover cap of the charging socket at the device A Close the cover cap of the charging socket again at an external storage battery A In order to maintain degree of protection IP69K make sure at devices with an external storage
2. S Send stable weight value SI Send weight value immediately SIR Send weight value repeatedly Z Zero the scale ZI Zero immediately LEVEL 1 D Write text into display DW Weight display K Keyboard check SR Send and repeat stable weight value T Tare TA Tare value TAC Clear tare TI Tare immediately In the case of Levels O and 1 these are commands which if implemented will function identically with all METTLER TOLEDO scales or weighing terminals In addition there are also further interface commands which apply either to the entire product series or to the particular application level This and further information on the MT SICS command set may be found in the MT SICS Manual Order Number 22 011 459 or at www mt com or be obtained by request from your METTLER TOLEDO customer service representative 35 Interface description IND429 IND429xx BBA429 4 1 2 Requirements for communication between scale and PC The scale must be connected to the RS232 RS485 USB or Ethernet interface of a PC with a suitable cable The interface of the scale must be set to Dialog mode see Section 4 6 1 A terminal progam must be available on the PC e g HyperTerminal The communication parameters baud rate and parity must be set in the terminal program and on the scale to the same values see Section 4 6 3 4 1 3 Notes on network operation via the optional interface RS422 485 Up to 32 scales can be networked with the opt
3. User manual METTLER TOLEDO Weighing terminal IND429 Weighing terminal IND429xx Compact scales BBA429 www mt com support ServiceXXL Tailored Services Congratulations on choosing the quality and precision of METTLER TOLEDO Proper use according to this Operating Manual and regular calibration and maintenance by our factory trained service team ensures dependable and accurate operation protecting your investment Contact us about a ServiceXXL agreement tailored to your needs and budget We invite you to register your product at www mt com productregistration so we can contact you about enhancements updates and important notifications concerning your product IND429 IND429xx BBA429 Table of contents User manual 22013801B 05 08 Table of contents Page Lip rs o eer 5 Safety instructions for the explosion protected weighing terminal Safety instructions for non explosion protected devices 6 BISDOSAL hist ii A nn ee nee 7 Use in hygienically sensitive areas ooo eeeeeeeeeee eee 7 BESAN P R 8 COMMISSIONING Re niet intense 12 OPEL Os ER nt 15 Switching on and 6 15 Zeroing Zero point correction 2 aiii edet sar iae oria dog d d deu da 15 Simple Weighing a EE E 15 Weighing With TOTB oe co ii 16 Dynamic weighirig isis sr rc d oe o eter ER 17 PER TESS ceci c encor alias cedar an ax
4. always observe the maximum permissible connected loads refer to the installation instructions It must be ensured that no voltages are fed into the device than it itself provides The interface parameters have to fulfil the standard A Peripheral devices without an Ex approval may only be operating in non hazardous areas It must be ensured that no voltages are fed into the device than it itself provides In addition the maximum permissible connected loads have to be observed refer to the installation instructions The interface parameters have to fulfil the standard A The safety of the weighing system is only guaranteed when the weighing system is operated installed and maintained in accordance with the respective instructions Introduction IND429 IND429xx BBA429 Ex approval Operation 1 2 A Also comply with the following the instructions for the system modules ihe regulations and standards in the respective country the statutory requirement for electrical equipment installed in hazardous areas in the respective country all instructions related to safety issued by the owner A Before initial start up and following service work check the explosion protected weighing system for the proper condition of all safety related parts A Prevent the build up of static electricity Therefore always wear suitable working clothes when operating or performing service work on the system do not ru
5. tan 39 Ea MAE tehing On ses Interface protocol 37 39 on Interfaces CONNGUIING kk 30 Connections 8 47 User manual 22013801B 05 08 55 22013801B Subject to technical changes Mettler Toledo Albstadt GmbH 05 08 Printed in Germany 22013801B Mettler Toledo Albstadt GmbH D 72458 Albstadt Tel 49 7431 14 0 Fax 49 7431 14 232 Internet http Awww mft com
6. 3 7 1 COMI COM2 gt MODE operating mode of the serial interface Print Manual data output to the printer with G A Print Automatic output of stable results to the printer e g for series weighing operations CONtINU Ongoing output of all weight values via the interface dIALOG Bi directional communication via MT SICS commands control of the scale via PC MMr Bidirectional communication via MMR commands controlling of a scale via a PC command set compatible to the weighing terminals ID1 and ID3 MMr A SIr Automatic continuous transmission a stable or dynamic weight value is transmitted after every measuring cycle CONt OLd As per CONCINU see above but with 2 fixed blanks in front of the unit compatible with Spider 1 2 3 dIAL OLd As per ATALOG see above but with 2 fixed blanks in front of the unit compatible with Spider 1 2 3 dt b DigiTOL compatible format GrOSS e Transfer of the gross weight identified with B tArE e Transfer of the tare weight nEt e Transfer of the net weight dt G As per dt b see above gross weight identified with G User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu COnt Wt TOLEDO Continuous mode 2nd dISP For connecting a second display automatically activates the 5 V voltage supply at Pin 9 InSt Prn Immediate manual data output to the printer with amp not certifiable 3 7 2 COM1 COM2 gt PRINTER
7. be verified by an authorized office or the METTLER TOLEDO Service gt Call the METTLER TOLEDO Service Adjust non verified analog scales for the maximum precision refer to Section 3 3 1 User manual 22013801B 05 08 IND429 IND429xx BBA429 Operation 2 Operation 2 1 Switching on Switching off 2 2 Automatic 2 3 User manual 22013801B 05 08 Switching on and off Press The scale conducts a display test Afterwards the software version identifier is dis played When the weight display appears the scale is ready to weigh Note If is pressed for a long time while switching on the serial number of the device is also displayed after the software version identifier Press Before the display goes out oFF appears briefly Zeroing Zero point correction Zeroing corrects the influence of slight changes on the load plate or minor deviations from the zero point 1 Unload scale 2 Press 609 The zero display appears In the case of scales that cannot be certified the automatic zero point correction can be deactivated in the menu or the amount can be changed Verified scales are set fixed to 0 5 d As standard the zero point of the scale is automatically corrected when the scale is unloaded Simple weighing 1 Place weighing sample on scale 2 Wait until the stability monitor O goes out 3 Read weighing result Operation IND429 IND429xx BBA429 2 4 2
8. bent too strongly User manual 22013801B 05 08 IND429 IND429xx BBA429 Introduction 1 3 1 4 User manual 22013801B 05 08 Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may not be disposed of with domestic waste This also applies to countries outside the EU per their specific requirements gt Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this device Should this device be passed on to other parties for private or professional use the content of this regulation must also be related Thank you for your contribution to environmental protection If the device is equipped with a storage battery The nickel metal hydride NiMH storage battery does not contain any heavy metals However it may not be disposed of with the normal refuse gt Observe the local regulations on the disposal of materials that are hazardous to the environment Use in hygienically sensitive areas The device is suitable for use in hygienically sensitive areas It fulfils the following requirements on areas coming into contact with the product keyboard and areas not coming into contact with the product housing stand e Suitability of the materia
9. of the right justified fill with left justified fill with response blanks blanks 2 3 characters Example Tare specification command Tare specification response 4 3 3 40 T 13 295 kg 13 295 kg Error messages Error messages consist of 2 characters and the delimiter CRLF Error Meaning Description message ET Transmission error Error in the received bit sequence e g parity error missing stop bit ES Syntax error The received character string cannot be processed e g command does not exist EL Logic error Command cannot be executed command is not supported on this application level User manual 22013801B 05 08 IND429 IND429xx BBA429 Interface description 4 3 4 User manual 22013801B 05 08 Available application blocks The device disposes of the following application blocks The numbers of application blocks that can be written are printed in bold No Content 002 Current program number 003 lt STX gt 004 lt ETX gt 006 lt CR gt lt LF gt 007 Gross 2nd unit 008 Net 2nd unit 009 Tare 2nd unit 011 Gross 1st unit 012 Net 1st unit 013 Tare 1st unit 014 Display contents 016 Dynamic weighing 41 Event and error messages IND429 IND429xx BBA429 5 Event and error messages Error Cause Remedy Display dark e Back lighting set too dark e No mains voltage e Unit switche
10. settings for protocol printout This menu item only appears if the mode Print or A Print is selected tYPE Select the printer type ASCII e ASCII printer GA46 e GA46 printer tEmPLat Selecting protocol printout StdArd e Standard printout tEmPLt1 e Printout in accordance with Template 1 tEmPLt2 e Printout in accordance with Template 2 ASCi Fmt Selecting formats for the protocol printout LINE Fmt e Line format MULET multiple lines SINGLE single lines or FIXEd Records are output in single lines Every record encompasses the number of character that was defined under LENGtH LENGTH e Line length 010100 characters is only displayed at the line format MULt I and FIXEd SEPArAt e Separator _ and space appears only with line format SINGLE Add LF e Line feed O 9 3 7 3 COM1 COM2 gt PARAMET communication parameters bAUd Selecting baud rate 300 600 1200 2400 4800 9600 19200 38400 baud PAritY Selecting parity 7 none 8 none 7 odd 8 odd 7 even 8 even H SHAKE Select handshake NO XONXOFF NET 422 network operation via the optional RS422 RS485 interface via 4 wire bus only for COM1 NET 485 network opera tion via the optional RS422 RS485 interface via 2 wire bus only for COMI NEt Addr Assigning network address O 31 only for NET 485 ChECSuM Activating checksum byte appears only in TOLEDO Continuous mode Vcc Switching 5 V voltage e g for a bar code reader or the optional interface RS485 422 on o
11. 28 rESEt SUrE 28 APPLIC AVErAGE OFF AUtO MAnuAL 29 rESEt SUrE 29 22 User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu User manual 22013801B 05 08 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Page tERMINL dEVICE SLEEP OFF 1 min 3 min 5 min 15 min 29 30 min PWr OFF OFF 1 min 3 min 5 min 15 min 30 min b LIGHt ON OFF 5 sec 10 sec 30 sec 1 min ACCESS SUPErVI 30 rESEt SUrE 30 COMMUNI COM 1 COM 2 MOGE Print 30 A Print CONt INU dIALOG MMr MMr A SIr CONt OLd dIAL OLd dt b GrOSS ON OFF tArE ON OFF nEt ON OFF dt G GrOSS ON OFF tArE ON OFF nEt ON OFF COnt Wt 2nd dISP InSt Prn PriNtEr tYPE ASCII GA46 31 tEMPLat StdArd tEMPLt1 tEMPLt2 ASCi Fmt LINE FMt MULtI SINGLE FIXEd LENGtH 1 24 100 SEPArAt xi Add LF 0 9 23 Settings in the menu IND429 IND429xx BBA429 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Page PArAMEt bAUd 300 2400 38400 31 PAritY 7 nonE 8 nonE 7 odd 8 odd 7 EVEN 8 EVEN H SHAKE NO XONXOFF nEt 422 nEt 485 NEt Addr 0 31 ChECSuM ON OFF Vcc ON OFF rSt COMx SUrE 32 COMMUNI OPtION EtH NEt IP AddrS SUbNEt GAtEWAY 32 WLAn IP AddrS SUbNEt GAtEWAY SIGNAL USb US
12. 4 1 2 4 2 2 4 3 Weighing with tare Taring gt Place the empty container on the scale and press 619 The zero display and the symbol NET appear The tare weight remains saved until it is cleared Clearing the tare gt Unload scale and press Ts The symbol NET goes out the zero display appears or Press a The symbol NET goes out the gross weight appears in the display If A CL tr is activated in the menu under SCALE gt tArE the tare weight is auto matically cleared as soon as the scale is unloaded Automatic taring Prerequisite A tArE is activated in the menu under SCALE gt tArE the symbol T flashes in the display The packaging material must be heavier than 9 display steps of the scale gt Place the container or packaging material on the scale The packaging weight is automatically saved as the tare weight the zero display and the symbol NET appear User manual 22013801B 05 08 IND429 IND429xx BBA429 Operation 2 4 4 2 5 With manual start User manual 22013801B 05 08 Chain tare Prerequisite The tare function CHAIn tr is activated in the menu under SCALE gt tArE With this function it is possible to tare several times if for example cardboard is placed between individual layers in a container 1 Place the first container or packaging material on the scale and press 619 The packaging weight is automatically saved as the tare weight the zero display and the
13. 9 Applications 44 MAE TOLEDO Continuous 37 Average 17 29 Communication 30 Diagnosis 34 U 0 Operation ssuusssse 209 SB 47 GOD tit 25 Overview 22 Chain faf tento 17 So DDR E DN 01600108 18 16001001 29 Verification 14 Compact 50016 8 Menu structure 21 w Continuous mode 37 0 Weighing terminal 8 D Operator MENU 20 Weighing al 25 21 Device overview cece 9 Options 32 WLAN seen 32 47 Digital 1 0 47 P Z Dimensions 46 47 j BI ane ipl P SSN I naga 20 2800106 15 Display accuracy 25 POWET Supply 12 13 Display precision 27 0010001 18 Dynamic weighing 17 29 p E Reset Error messaggs 42 Application 29 saa 32 Ethernet cette 47 26 2 Explosion protected weighing Scale 6 28 NOR MONDEO B 1610011061 30 RBZ Zen 45 47 External power supply 8 14 49 HAL ROAD on 47 F RS422 RS485 coco annui 36 EIR tes 20 28 CRSdBS saec oerte 47 H S Hygienically sensitive areas 7 18 Safety checks 000 50 50 Safety instructions 5 SICS commands 35 i Storage battery operation 13 46 Ignition protection type ZI III 45 Supervisor MONU ccccccccccceceeee 20 Interface commands Switching off 15 MMR aan
14. BBA429 Appendix 7 4 2 GEO VALUES 6000e 7500e OIML Class lll Height lt 1000 m Geographical latitude Geo value 00 00 12 44 5 05 46 17 10 6 12 44 20 45 7 17 10 23 54 8 20 45 26 45 9 23 54 29 25 10 26 45 31 56 11 29 25 34 21 12 31 56 36 41 13 34 21 38 58 14 3641 41912 15 38 58 43 26 16 41 12 45 38 17 43 26 47 51 18 45 38 50 06 19 47 51 52 22 20 50 06 54 41 21 52 22 57 04 22 54 41 59 32 23 57 04 62 09 24 59 32 64 55 25 62 09 67 57 26 64 55 71 21 27 67 57 75 24 28 71 21 80 56 29 75 24 90 00 30 User manual 22013801B 05 08 53 Appendix IND429 IND429xx BBA429 54 7 5 FCC This equipment has been tested and found to comply with the limits for a Class A dig ital device pursuant to both Part 15 of the FCC Rules and the radio interference regu lations ot the Canadian Department of Communications These limits are designed to provide a reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radi ate radio frequency energy and if not installed and used in accordance with the user manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to
15. D CR CHK Field 1 Cont Wt 6 digits for the weight value that is transferred without comma and unit Field 2 Cont Wt 6 digits for the tare weight that is transferred without comma and unit STX ASCII character 02 hex character for start of text SWA SWB SWC Status words A B C see below MSD Most significant digit LSD Least significant digit CR Carriage Return ASCII character OD hex CHK Checksum 2 complement of the binary sum of the lower 0119 of all the characters sent beforehand incl STX and CR 37 Interface description IND429 IND429xx BBA429 Function Decimal position Numerical increment Status word Selection X00 XO X OX 0 0 0 00 0 000 0 0000 XI X2 X5 Status bit 6 0 Status word B Function Value Gross Net Net 1 Sign Negative Overload Underload 1 Movement Ib kg kg 1 Power up OO NN O 2 1 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 Status word C Function Value kg Ib g t 0z Bit 0 0 0 0 0 0 0 0 Print request Extended Tare manually only kg oo A UIN O 38 User manual 22013801B 05 08 IND429 IND429xx BBA429 Interface description 4 3 4 3 1 User manual 22013801B 05 08 MMR interface commands The device supports the command set MMR METTLER MultiRange This
16. Ethernet interface e USB interface e Digital I O e WLAN User manual 22013801B 05 08 IND429 IND429xx BBA429 Introduction 1 5 4 Overview 1 Keys 2 Display 3 Measuring data sign e e 1 Weighing terminal connections 1 Power supply connection 2 Pressure compensation Equipotential bonding terminal only for INDA29xx COMI interface COM2 interface Coptional 6 Antenna for optional WLAN interface 7 notassigned Scale connection 9 Securing plate for the interface connections only for INDA29xx User manual 22013801B 05 08 9 Introduction IND429 IND429xx BBA429 COMI interface COM2 interface optional Antenna for optional WLAN interface Pressure compensation Power supply connection Scale connection 1 5 5 Compact scale connections 5 Display 1 2 3 es 4 uc Dump m m rm Soe 10 20 DI CI 0 CI CI Choose s tok LI CILE LIE KkgPes 9 pL 8 7 1 Notation for weight values with e 10 d 2 Active interface 3 Weighing range display 4 Charge state of the storage battery only for devices with storage battery 5 Symbol for displaying net values 6 Symbol for dynamic weighing 7 Weight units 8 7 segment display 7 digits with decimal point 9 Standstill check goes out when a stable weight value has been rea
17. Exiting menu Note User manual 22013801B 05 08 Selecting and setting parameters Scroll forward Press ETO gt Scroll back Press 609 gt Press 1 Press The last menu item End appears 2 Press E The inquiry SAVE appears 3 Confirm inquiry with amp to save the settings and return to weighing mode or gt Press T9 to discard changes and return fo weighing mode The SCALE menu block depends on the built in scale interface 21 Settings in the menu IND429 IND429xx BBA429 3 2 Overview Factory settings are printed bold in the following overview Level 1 Level 2 Level 3 Level 4 flevel5 o Level 6 Page SCALE CAL 25 analog dISPLAY UNIt1 g kg oz 1b t 25 UNIt2 g kg oz lb t rESOLU UNt rOLL ON OFF tArE A tArE ON OFF 25 ChAIn tr ON OFF A CL tr ON OFF 9 d ZErO AZM OFF 0 5 d 1d 2d 5 d 10 d 25 rEStArt ON OFF 26 FILtEr VibrAt LOW MEd HIGH 26 PrOCESS UNIVEr dOSING StAbILI FASt StAndrd PrECISE Min WEiG ON OFF ON OFF 26 rESEt SUrE 26 SCALE dISPLAY UNIt2 g kg oz lb t 27 IDNet UNt rOLL ON OFF tArE A tArE ON OFF 27 ChAIn tr ON OFF A CL tr ON OFF 9 d ZErO AZM ON OFF 27 rEStArt ON OFF 27 FILtEr VibrAt StAbLE nOrMAL UnStAbL 28 PrOCESS FinEFiL UNIVErS AbSOLUt StAbILI ASd 0 ASd 1 ASd 2 ASd 3 ASd 4 UPdAtE Setting possibilities depend on the connected scale 28 Min WEiG ON OFF ON OFF
18. Internet under www mt com NSF is an independent NGO founded in 1944 in the USA Corresponding regulations were published for the use of devices in the foodstuff industry The device fulfils the NSF criteria C 2 Special Equipment and or Devices for use in the foodstuff industry The corresponding certificate is available on the Internet under www mt com User manual 22013801B 05 08 IND429 IND429xx BBA429 Appendix 1 3 7 4 7 4 1 User manual 22013801B 05 08 Working to GMP Good Manufacturing Practice Weighing terminal INDA29 and compact scale BBA429 were evaluated by the Stein beis Transferinstitut Berlin with the following result The device is excellently suited for GMP working to EC GMP Guideline Annex 15 and PIC S Guideline PI 006 1 The evaluation encompasses the following points e Requirements for surfaces in the pharmaceutical production e Ability to be cleaned e Calibration e Documentation with regard to qualification The corresponding certificate is available on the Internet under www mt com Tables of geo values For weighing instruments verified at the manufacturer s the geo value indicates the country or geographical zone for which the instrument is verified The geo value set in the instrument e g Geo 18 appears briefly after switch on or is specified on a label Table GEO VALUES 3000e shows the geo values for European countries Table GEO VALUES 6000e 7500e shows the geo values for
19. RJ45 USB adapter cable 0 2 m gt USB Series A socket 22 006 268 USB adapter cable 3 m gt USB Series A socket 22 007 713 Relay box for digital I O option 22 011 967 not for a hazardous area Connection cable Digital I O option with relay box 10 m 00 504 458 Digital I O mating plug 19 pin 00 504 461 Protective hood for INDAx9 terminals set with 3 pieces 22 013 963 not for a hazardous area Protective hood for BBA4x9 compact scales set with 3 pieces 22 013 992 Stand stainless steel for INDAx9 and PBA430 height 330 mm 22 013 964 Stand stainless steel for INDAx9 and PBA430 height 660 mm 22 013 965 User manual 22013801B 05 08 IND429 IND429xx BBA429 Technical data and accessories User manual 22013801B 05 08 Designation Order number Stand stainless steel for INDAx9 and KA KB MA MB and DB 22 014 836 weighing platforms Bench stand stainless steel for IND4x9 suitable for mounting 22 014 835 frame 503632 and 504854 Floor stand stainless steel for IND4x9 22 014 834 Stand base for floor stand 22 011 982 Wall adapter stainless steel for IND4x9 tiltable 22 013 966 Wall bracket stainless steel for INDAx9 rotatable and tiltable 22 014 833 GA46 mounting plate stainless steel for bench stand floor 22 011 985 stand and wall bracket External storage battery for BBA4x9 stainless steel IP69K 22 013 988 without charger Charger for version with internal o
20. als and permissible cleaning agents User manual 22013801B 05 08 IND429 IND429xx BBA429 Operation 2 8 2 8 1 2 8 2 Note User manual 22013801B 05 08 Information on cleaning the weighing platform connected to the weighing terminal gt Be sure to observe the cleaning instructions for the connected weighing platform The weighing platform may not be designed for cleaning with high pressure equipment Testing of weighing terminal and scale display of the ID code only for weighing terminals with IDNet interface The ID code is increased by 1 at every calibration in case of IDNet scales For verified scales the ID code displayed by the weighing terminal must match the ID code on the ID cards Otherwise the verification is no longer valid Displaying the ID code 1 Unload weighing platform 2 Press the key and keep it pressed until the display changes to The ID code is then displayed COdE Testing the weighing platform and terminal gt After the ID code is displayed press the key again CHE CAL is displayed The weighing platform is tested After a successful test CAL ok is displayed briefly The terminal then changes to normal operation If a calibration error CAL Err is displayed during testing repeat the test If the error is displayed again inform the METTLER TOLEDO Service Settings in the menu IND429 IND429xx BBA429 3 Settings in the menu 3 1 Operator menu Supervis
21. andard Digital I O RS232 Digital 1 0 Standard WLAN RS232 WLAN 47 Technical data and accessories IND429 IND429xx BBA429 6 2 Accessories 48 Designation Order number GA46 thermal printer RS232 2 5 m cable and connector incl 00 505 471 not for a hazardous area GA46 thermal printer RS232 0 4 m cable and connector incl O0 507 229 not for a hazardous area GA46 W thermal printer take up device protective hood 00 505 799 RS232 2 5 m cable and connector incl not for a hazardous area GA46 W thermal printer take up device protective hood 00 507 230 RS232 0 4 m cable and connector incl not for a hazardous area Secondary display ADIA19 display without background 22 013 962 lighting stainless steel IP69K RS232 3 m cable incl not for a hazardous area Secondary display ADI4 1 9 8 display with background lighting 22 014 022 stainless steel IP69K RS232 3 m cable incl not for a hazardous area RS232 cable for SICS second scale 22 006 795 3 m 8 pin lt gt 9 pin Sub D connector RS232 cable for PC 3 m 8 pin lt gt 9 pin Sub D socket 00 504 376 RS232 mating plug 8 pin 00 503 756 RS422 RS485 cable 3 m 6 pin lt gt open ends 00 204 933 RS422 RS485 mating plug 6 pin 00 204 866 Ethernet 10 100 Base T twisted pair cable 5 m gt 8 pin RJ45 00 205 247 Ethernet 0 100 Base T twisted pair cable 00 208 152 20 m gt 8 pin
22. ay E rr 1 H scale faulty back in In case of battery operation switch the device off and on again gt Call METTLER TOLEDO service Z e Restart error gt Remove and plug the power plug F rr j e back in In case of battery operation switch the device off and on again gt Call METTLER TOLEDO service RM e Weighing error gt Remove and plug the power plug E rr 4 j back in In case of battery operation switch the device off and on again gt Call METTLER TOLEDO service e EAROM checksum error gt Unplug the mains plug then plug Frere 54 it back in switch unit off and then back on in battery mode gt Call METTLER TOLEDO Service Weight display unstable e Restless installation location gt Adjust vibration adapter e Draft e Restless weighing sample e Contact between weighing pan and or weighing sample and surroundings e Mains fault e Incorrect zeroing e Incorrect tare value e Contact between weighing pan and or weighing sample and surroundings e Scale tilted gt Avoid drafts gt Weigh dynamically gt Remedy contact Check mains gt Unload scale set to zero and repeat weighing operation Clear tare gt Remedy contact Level scale User manual 22013801B 05 08 43 Technical data and accessories IND429 IND429xx BBA429 6 Technical data and accessories 6 1 Technical data 6 1 1 General data IND429 IND429xx BBA429 Applications e Weigh
23. b or wipe off the keyboard surface with a dry cloth or glove A Do not use protective hoods A Prevent damage to the weighing terminal Hairline cracks in the keyboard membrane are also considered damage A If the weighing terminal accompanying weighing platforms or accessories are damaged Switch off weighing terminal Separate the weighing terminal from the mains in accordance with the applicable regulations Secure the weighing terminal against accidental start up A Always charge the storage batteries in a safe zone A Ensure that the supply voltage at the installation site amounts to 230 V Safety instructions for non explosion protected devices A Do not use the device in an hazardous environment Special devices are available in our range of products for hazardous environments A Ensure that the power socket outlet for the device is earthed and easily accessible so that it can be de energized rapidly in emergencies A Ensure that the supply voltage at the installation site lies within in the range of 100 V to 240 V A The safety of the device cannot be ensured if it is not operated in accordance with these operating instructions A Only authorized personnel may open the device A Check the power cable regularly for damage If it is damaged disconnect the device immediately from the power supply A Ensure that there is a space of at least 3 cm atthe rear in order to prevent the power cable from being
24. b tESt diGitAL IN 0 3 OFF ZErO tArE Print CLEAr UNIt OUt 09 OFF StAbLE bEL Min AbV Min UndErLd OVErLd StAr SEt Pt 1 SEt Pt 2 dEF PrN tEMPLt1 LINE 1 NOt USEd HEAdEr 33 tEMPLt2 LINE 8 GrOSS tArE nEt StArLN CrLF F FEEd dIAGNOS tESt SC 34 KboArd dISPLAY SNr List rESEt AL SUrE 24 User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu 3 3 Scale settings SCALE analog 3 3 1 CAL calibration adjustment This menu item is not available for certified scales CAL 1 Unload scale 2 Activate menu item CAL with E The scale determines the zero point 0 appears in the display The calibration weight to be placed on the scale then flashes in the display 3 If necessary change the weight value displayed with 619 4 Place the calibration weight on the scale and confirm with The scale calibrates with the calibration weight loaded After calibration is com pleted donE appears briefly in the display and the scale automatically returns to weighing mode In order to achieve particularly high precision calibrate under full load 3 3 2 DISPLAY weighing unit and display accuracy UNIt1 Select weighing unit 1 g kg oz Ib t UNIt2 Select weighing unit 2 g kg oz Ib t rESOLU Select readability resolution model dependent UNt rOLL When UNT rOLL is switched on the weight value can be display
25. battery that the external storage battery is connected firmly to the device Ensure that the plug connector of the external storage battery is inserted into the socket outlet of the device until it will go no further The storage battery is also suitable for permanent mains operation gt In order to obtain the full nominal capacity we recommend that you discharge the storage battery at regular intervals approx every 4 weeks through normal operation Introduction IND429 IND429xx BBA429 1 6 6 1 6 7 Note Devices with external power supply 12 24 V DC Explosion protected weighing terminals IND429xx The device is supplied with a fixed mounted 2 5 m long connecting cable with open ends Connection values 12 24 V DC max 800 mA Non explosion protected devices The device is equipped with a socket for connecting the power supply Connection values 12 24 V DC max 800 mA A connecting cable with open ends is included with the device CAUTION Danger of soiling A In order to maintain degree of protection IP69K make sure at devices with an external power supply that the connecting cable is connected firmly to the device Ensure that the plug connector of the connecting cable is inserted into the socket outlet of the device until it will go no further Verification at partially verified scales Partially verified scales scales with first stage verification and scales with IDNet interface have to
26. cause harmful interference in which case ihe user will be required to correct the interference at his own expense Cet appareil a t test et s est av r conforme aux limites pr vues pour les appareils num riques de class A et la partie 15 des r glements FCC et la r glementation des radio Interf rences du Canadian Department of Communications Ces limites sont destin es fournir une protection ad quate contre les interf rences n fastes lorsque l appareil est utilis dans un environnement commercial Cet appareil g n re utilize et peut radier une nergie fr quence radio lectrique il est en outre susceptible d engendrer des interf rences avec les communications radio s il n est pas install et utilis conform ment aux instructions du mode d emploi L utilisation de cet appareil dans les zones r sidentielles peut causer interf rences n fastes auquel cas l exploitant sera amen prendre les dispositions utiles pour palier aux interf rence Ses propres frais User manual 22013801B 05 08 IND429 IND429xx 884429 Index 8 Index A K T Accessories 48 Keyboard 11 Tare Additional equipment 8 M Automatic 16 Adjustment esce tees tease 25 Choin 10 17 Ambient conditions 45 Mains connection 12 13 45 Clearing 16 Analog scale 45 Menu Terminal settings 29 n Application 2
27. ces nOrMAL e Normal environment The scale operates at medium speed UnStAbL e Restless environment The scale operates more slowly but is insensitive to exter nal influences PrOCESS Adaptation to the weighing process FinEFiL e Dispensing of liquid or powdered weighing samples UniVErs e Universal setting for all weighing modes and normal weighing samples AbSOLUt e For solid bodies under extreme conditions e g strong vibrations StAbILI ASD 0 Stability monitoring switched off Only possible for non verifiable weighing platforms ASd 0 ASd 4 ASD 1 Rapid display Good reproducibility ASD 2 ft y ASD 3 ft V ASD 4 Slow display Excellent reproducibility 3 4 6 UPDATE setting the display speed of the weight display This menu item is only displayed if the UPDATE function is supported by the connected weighing platform xx 95 Selecting the number of updates per second UPS The possible settings depend on the connected weighing platform 3 4 7 MIN WEIG minimum weighing in quantity This menu item appears only if the service technician has saved a minimum weight ON OFF Switching minimum weight function on off If the weight on the scale falls below the stored minimum weight an appears on ihe display in front of the weight indicator 3 4 8 X RESET resetting scale settings to factory settings SUrE Confirmation inquiry e Reset the scale settings to factory settings with E e Do not reset scale s
28. ched 10 Sign 11 Notation for modified or calculated weight values e g higher resolution weight below minimum value User manual 22013801B 05 08 IND429 IND429xx BBA429 Introduction 1 5 6 lt Keyboard Main functions Function in the operating mode Switch the terminal on off cancel Function in the menu To the last menu item End Set scale to zero delete tare Long keypress at scales with IDNet interface Display of the ID code and checking of the calibration Tare scale delete tare Page backwards Page forwards 909 e Transfer key Long keypress Call up menu Activate menu item Accept selected setting Additional functions x lt Function Switch over weight unit User manual 22013801B 05 08 Delete key Introduction IND429 IND429xx BBA429 gt gt 1 6 1 6 1 1 6 2 1 6 3 Commissioning The weighing platform connection to the weighing terminals IND429 IND429xx as well as the commissioning of the interfaces are described in the INDAx9 BBA4x9 installation instructions gt Call the METTLER TOLEDO service or carry out commissioning in accordance with the installation instructions Limited mobility at explosion protected weighing terminal IND429xx CAUTION The device may only be operated in Zone 2 and 22 hazardous areas A Protect data and signal cable extensions against inadvertent disconn
29. command set is compatible to the weighing terminals ID1 and ID3 For new installations we recommend the SICS command set refer to Section 4 1 Available MMR commands Com Meaning mand AR Read application block AW Write application block D Describe display RO Switch on the keyboard RI Switch off the keyboard S Transmit stable weight value SI Transmit weight value immediately SIR Transmit weight value immediately and repeat SR Transmit stable weight value and repeat SX Transmit stable data record SXI Transmit data record immediately SXIR Transmit data record immediately and repeat T Taring U Switch over weight unit Z Setting to zero 39 Interface description IND429 IND429xx BBA429 4 3 2 Syntax and formats Commands have to be entered as ASCII characters and completed with CpLr The following ASCII characters are available 20 hex 32 dec 7F hex 127 dec Command format when transmitting weight values Identification Weight value _ Unit Limit String of characters for Blank 8 digits Blank 1 3 characters CRLF specification of command Number of digits Number of characters 1 4 characters variable variable Response format when transmitting weight values Identification Weight value Unit Limit String of characters for Blank 10 digits Blank 3 characters 0 specification
30. d off e Mains cable not plugged in e Brief fault gt Set back lighting b LIGHt brighter gt Check mains gt Switch on unit gt Plug in mains plug Switch device off and back on again Insufficient load L 4 4 l e Load plate not on the scale e Weighing range not reached gt Place load plate on the scale gt Set to zero Overload rrr rw sy e Weighing range exceeded gt Unload scale gt Reduce preload e Result not yet stable gt If necessary adjust vibration adapter or weigh dynamically e Function not permissible Unload scale and set to zero e Zeroing not possible with over load or insufficient load Unload scale e No calibration gt Unplug the mains plug then plug it back in switch unit off and then back on in battery mode gt Calibrate scale Call METTLER TOLEDO Service mal e Printout not yet ended gt End printout gt Repeat required action rn T co e Switching the weighing unit impermissible during dynamic weighing gt End dynamic weighing m9 Lact EA e No IDNet scale found gt Check connectors and cabling gt Call METTLER TOLEDO service 42 User manual 22013801B 05 08 IND429 IND429xx BBA429 Event and error messages Error Cause Remedy e Data communication with IDNet gt Remove and plug the power plug Incorrect weight displ
31. different gravitation zones GEO VALUES 3000e OIML Class III European Countries Geographical latitude Geo value Country 46 22 49 01 18 Austria 49 30 51 30 21 Belgium 41 41 44 13 16 Bulgaria 42 24 46 32 18 Croatia 48 34 51 03 20 Czechia 54 34 57 45 23 Denmark 57 30 59 40 24 Estonia 59 48 64 00 25 Finland 64 00 70 05 26 41 20 45 00 17 France 45 00 51 00 19 47 00 55 00 20 Germany 34 48 41948 15 Greece 45 45 48 35 19 Hungary 51 Appendix IND429 IND429xx BBA429 52 Geographical latitude Geo value Country 63 17 67 09 26 Iceland 51 05 55 05 22 Ireland 35 47 47 05 17 Italy 55 30 58 04 23 Latvia 47 03 47 14 18 Liechtenstein 53 54 56 24 22 Lithuiania 49 27 50 11 20 Luxemburg 50 46 53 32 21 Netherlands 57 57 64 00 24 Norway 64 00 71 11 26 49 00 54 30 21 Poland 36 58 42 10 15 Portugal 43 37 48 5 18 Romania 47 44 49 46 19 Slovakia 45 26 46 35 18 Slovenia 36 00 43 47 15 Spain 55 20 62 00 24 Sweden 62 00 69 04 26 45 49 47 49 18 Switzerland 35 51 42 06 16 Turkey 49 00 55 00 21 United Kingdom 55 00 62 00 23 factory setting User manual 22013801B 05 08 IND429 IND429xx
32. e Normal environment The scale operates at medium speed HIGH e Restless environment The scale works more slowly but is insensitive to external influences PrOCESS Adaptation to the weighing process UNIVEr e Universal setting for all weighing samples and normal weighing goods dOSING e Dispensing liquid or powdery weighing samples StAbILI Adjusting the stability detector FASt e The scale operates very fast StAndrd e The scale operates at medium speed PrECISE e The scale operates with the greatest possible reproducibility The slower the scale works the greater the reproducibility of the weighing results 3 3 7 MIN WEIG minimum weight This menu item appears only if the service technician has saved a minimum weight ON OFF Switching minimum weight function on off If the weight on the scale falls below the stored minimum weight an appears on ihe display in front of the weight indicator 3 3 8 X RESET resetting scale settings to factory settings SUrE Confirmation inquiry e Reset the scale settings to factory settings with amp e Do not reset scale settings with 619 26 User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu 3 4 Scale settings SCALE IDNet 3 4 1 DISPLAY weighing unit UNIt2 Select weighing unit 2 g kg oz Ib t UNt rOLL When UNT rOLL is switched on the weight value can be displayed in all available units with Note
33. ection A Secure the interface connections on the rear using the interface plate Labelling for operation in hazardous area The following signs must be mounted on the device accompanying weighing platforms and accessories so that they are clearly visible e Model plate and the device s model data manufacturer and serial number e Safety instructions e Explosion protection identification e If appropriate temperature range Establishing a mains connection at an explosion protected weighing terminal IND429xx CAUTION The mains connection may only be connected by the owner s electrician CAUTION The device only operates correctly at a supply voltage of 230 V A Do not under any circumstances connect the device if the voltage value on the rating plate deviates from the local system voltage A Only connect the device to an earthed mains connection A Ensure that equipotential bonding has been implemented User manual 22013801B 05 08 IND429 IND429xx BBA429 Introduction 1 6 4 1 6 5 m Note User manual 22013801B 05 08 Establishing a mains connection at non explosion protected devices CAUTION Before connecting the power supply check whether the voltage value printed on the rating plate agrees with the local system voltage A Do not under any circumstances connect the device if the voltage value on the rating plate deviates from the local system voltage gt Plug the power plug into the power socket
34. ed in all available units with Notes e n the case of certified scales individual sub items of the dISPLAY menu item may not be available or only to a limited extent depending on the respective country e On dual range dual interval scales resolutions marked with I 51 1 2 are divided up into 2 weighing ranges intervals e g 2 x 3000 d 3 3 3 TARE tare function A tArE Switching on off automatic taring CHAIn tr Switching on off chain tare A CL tr Switching on off automatic clearing of the tare weight when the load is removed from scale Possible settings OFF ON 9 d 3 3 4 ZERO automatic zero update AZM On certified scales this menu item does not appear Switching on off automatic zero update and selecting zeroing range Possible settings OFF 0 5 d 1d 2d 5d 10d User manual 22013801B 05 08 25 Settings in the menu IND429 IND429xx BBA429 3 3 5 RESTART automatic saving of zero point and tare value ON OFF When the Restart function is activated the last zero point and tare value are saved After switching off on or after a power interruption the device continues to work with the saved zero point and tare value 3 3 6 FILTER adaptation to the ambient conditions and the weighing type VIbrAt Adaptation to the ambient conditions LOW e Very steady and stable environment The scale works very rapidly but is very sensitive to external influences MEd
35. eted the deviation from the last calibration briefly appears in the display ideally a 0 Og after which the scale changes to the next menu item KboArd KboArd Keyboard test PUSH 1 6 e Press the keys 619 amp in order If the key works the scale changes to the next key Note You cannot abort the keyboard test If you have selected the menu item KboArd you must press all keys dISPLAY Display test The scale displays all functioning segments SNr Display of the serial number List Printout of a list of all menu settings rESEt AL Resetting all menu settings to the factory settings SUrE Confirmation inquiry e Reset all menu settings to the factory settings with gt e Do not reset the menu settings with 6T 34 User manual 22013801B 05 08 IND429 IND429xx BBA429 Interface description 4 Interface description User manual 22013801B 05 08 4 1 5103 interface commands The device supports the command set MT SICS METTLER TOLEDO Standard Interface Command Set With SICS commands it is possible to configure query and operate the scales from a PC SICS commands are divided up into various levels 4 1 1 Available SICS commands Command Meaning LEVEL 0 Reset the scale lO Inquiry of all available SICS commands E Inquiry of SICS level and SICS versions 12 Inquiry of scale data I3 Inquiry of scale software version 14 Inquiry of serial number 16 Inquiry of weighing parameters
36. ettings with 28 User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu 3 5 Application settings APPLICATION 3 5 1 X AVERAGE determining the average weight for an unstable load OFF Calculating average weight switched off AUtO Calculating average weight with automatic start of the weighing cycle MAnuAL Calculating average weight with manual start of the weighing cycle via E 3 5 2 RESET resetting application settings to factory settings SUrE Confirmation inquiry e Reset the application settings to factory settings with E e Do not reset the application settings with 619 3 6 Terminal settings TERMINAL 3 6 1 DEVICE sleep mode energy saving mode and display backlighting SLEEP This menu item only appears on devices in mains operation When SLEEP is activated the scale switches off display and backlighting after the time period set when not in use The display and backlighting are switched on again at the press of a key or if the weight changes Possible settings OFF 1 min 3 min 5 min 15 min 30 min PWr OFF This menu item only appears on devices in battery operation When Pwr OFF is activated the device switches itself off automatically after approx 3 minutes when not in use After this it must be switched on again using Possible settings OFF 1 min 3 min 5 min 15 min 30 min b LIGHt Set the background lighting of the display OFF 5 sec Set
37. ff User manual 22013801B 05 08 31 Settings in the menu IND429 IND429xx BBA429 3 7 4 COM1 COM2 gt RESET COM1 RESET COM2 resetting serial interface to factory settings SUrE Confirmation inquiry e Reset interface settings to factory settings with e Do not reset the interface settings with 619 3 7 5 OPTION configuring options If no option is installed or is not yet configured N A appears in the display EtH NEt Configuration of the Ethernet interface IP Addrs e Enter IP address SUbNEt e Enter Subnet address GACEWAY e Enter Gateway address WLAn Configuration of the WLAN interface IP Addrs e Enter IP address SUbNEt e Enter subnet address GAtEWAY e Enter gateway address SIGNAL e SIG shows the signal strength of the WLAN connection as a percentage value O to 25 very weak 26 to 49 weak 50 to 74 good 7510 100 excellent Reliable operation requires at least a good signal strength USb Configuration of the USB interface USb tESt e Test of the USB interface After the test has been passed x EAaY appears in the display diGitAL Configuration of the digital inputs outputs IND eas d Configuring inputs O 3 OFF e Input not assigned ZErO e Key tArE e Key 619 PriNt e Key CLEAr e Key UNIt e Key 32 User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu OUt 0 3 Configuring outputs O 3 OFF e Output not assig
38. i OU nni Xa T una Sia 18 Cleaning MN 18 Testing of weighing terminal and scale display of the ID code only for weighing terminals with IDNet interface sssssssee 19 Settings in the menu eere 20 Operating 1 20 22 Scale settings SCALE analog aa cc i Eel Re a 25 Scale settings SCALE IDNet sssem 27 Application settings APPLICATION 2 29 Terminal settings TERMINAL ereere 29 Configuring interfaces COMMUNICATION an 30 Diagnosis and printing out of the menu settings DIAGNOS 34 Interface description 35 SICS interface commands socio rn rede na pee Ea dta 35 TOLEDO Continuous mode cease dee les oso e latine 97 MMR interface COMMONOS o2 e edis ic er ete eade i xe reddit 39 Event and error messages mm mnnnnrenrenree 42 Technical data and accessories 44 T chnical dafd sitr ir eet eter eere tack re ee a AS 44 PCCESSOMOS p eH EUR UE 48 3 Table of contents IND429 IND429xx BBA429 7 1 7 2 7 3 7 4 7 5 ELU qe CEA 50 Safety Chee Ks an ee dui Poco RR Er st ON tara 50 Tests for utilisation in hygienically sensitive areas 50 Working to GMP Good Manufacturing Practice 0 etta 5 Tables of geo values 00 annn a ann nnrnnnrnanrnnrenett 5 RS 54 I TE 55 U
39. ing e Dynamic weighing Settings e Resolution can be selected Weighing unit can be selected g kg oz Ib t Taring function Manual automatic next tare Automatic zero compensation mode during switching on and during operation Filter for adapting to the environmental conditions vibration adapter Filter for adapting to the weighing mode e g dispensing weighing process adapter Switch off function sleep mode for power operated devices energy saving mode for storage battery operation Display illumination Display LCD liquid crystal display digit height 16 mm backlighting Keyboard e Tactile touch membrane keypad Scratch resistant labelling Housing e Stainless steel 1 4301 or AISI 304 e For dimensions see Page 46 Net weight e IND429 IND429xx with AC power approx 2 2 kg supply unit e IND429 IND429xx with storage approx 2 8 kg battery e BBA429 A with AC power supply unit approx 9 0 kg e BBA429 A with storage battery approx 9 6 kg e BBA429 BB with AC power supply approx 12 1 kg unit e BBA429 BB with storage battery approx 12 7 kg Protection type e P69K DIN 40050 44 User manual 22013801B 05 08 IND429 IND429xx BBA429 Technical data and accessories IND429 IND429xx BBA429 Mains connection Direct connection to power supply supply voltage fluctuation not exceeding 10 96 of the rated voltage e IND429 weighing terminal Rated voltage 100 240 VAC 47 63 H
40. ing horizontal segments appear in the display and the dynamic result is then displayed with the symbol 2 Unload the scale to be able to perform a new dynamic weighing operation Printing results If a printer or computer is connected to the scale the weighing results can be printed out or sent to a computer Press amp The display contents are printed out or transferred to the computer Cleaning The device conforms to degree of protection IP69K to DIN 40050 It is suitable for hygienically sensitive areas see the proofs in Section 7 2 The device is designed so that it can be cleaned easily The housing is made of stainless steel 1 4301 AISI 304 the keyboard of resistant polyester PE If required high pressure equipment can be used for cleaning Cleaning e Close open connectors with cap plugs e Clean the protective hood of the non explosion protected devices separately The protective hood is dishwasher proof e Replace protective hoods regularly e Use a moist cloth for minor soiling e Do not use acids alkaline solutions or strong solvents e Observe the following limits when using high pressure equipment Max water temperature 80 C 176 F Max water pressure 8 000 kPa 80 bars Min distance jet nozzle to terminal 50 cm Do not point the jet at one point for longer than 10 seconds Water flow rate not greater then 10 l min e Observe all the existing regulations on cleaning interv
41. ional RS422 485 interface In network operation the scales must be addressed from the computer before commands can be sent and weighing results received Address Hex ASCII 0 0x30 0 1 0x31 2 0x32 2 9 0x39 9 10 Ox3A 11 Ox3B 31 Ox4F O Description of the steps Host Direction Scale 1 Host addresses the scale e g with the address lt ESC gt gt 3A hex Host sends a SICS command e g SI SI lt CRLF gt gt The scale confirms receipt of the command and lt lt ESC gt sends the address back 4 The scale responds to the command and returns lt SS 4502 kg control of the bus to the host lt CRLF gt 36 User manual 22013801B 05 08 IND429 IND429xx BBA429 Interface description 4 2 TOLEDO Continuous mode User manual 22013801B 05 08 4 2 1 TOLEDO Continuous commands In TOLEDO Continuous mode the scale supports the following input commands Command Meaning P Printing out the current result T Taring of the scale Z Zero setting of the display C Deleting of the current value 4 2 2 Output format in TOLEDO Continuous mode Weight values are always transferred in TOLEDO Continuous mode in the following format Status Field 1 Field 2 1 2 3 14 5 16 17 18 9 10 11 12 13 14 15 16 17 18 STX SWA SWB SWC MSD ILSDI MSD LS
42. ls for contact with foodstuffs e Continuous bonding joints that do not act on the material e Smooth non porous and flat surfaces that are easy to clean e Continuous welding seams e No sharp corners For further information please refer to Sections 7 2 and 7 3 Introduction IND429 IND429xx BBA429 1 5 1 5 1 1 5 2 1 5 3 Description Weighing terminals IND429 and IND429xx METTLER TOLEDO weighing platforms can be connected without problems to the weighing terminals The weighing terminals are available in two different basic versions for connecting analog scales or for digital scales with IDNet interface Both basic versions are supplied by default with in built power supply unit and an RS232 interface IND429xx is approved for use in hazardous areas of the Category 3 Compact scale BBA429 The compact scale BBA429 consists of a terminal stand combination that is connected to an analog weighing platform of the PBA430 series The compact scale is supplied by default with an in built power supply unit and an RS232 interface Additional equipment The following alternatives are also possible e Power supply via in built storage battery e Version for external power supply 12 24 V DC e Power supply via an external storage battery not for INDA29xx e Additional second communication interface One of the following options is available as the second communication interface e RS232 e RS485 RS422 e
43. ned StAbLE e Stable weight value bEL Min e Minimum weight not reached AbV Min e Minimum weight reached or exceeded UNdErLd e Insufficient load OVErLd e Overload StAr e Changed calculated value bEL SP1 e Setpoint 1 not reached AbV SP1 e Setpoint reached or exceeded bEL SP2 e Setpoint 2 not reached AbV SP2 e Setpoint 2 reached or exceeded SEt Pt1 Enter value for setpoint 1 SEt Pt2 Enter value for setpoint 2 3 7 6 DEF PRN configuring templates tEMPLt1 tEMPLt2 Selecting Template or Template 2 LINE 1 8 Selecting line NOt USEd e Line not used HEAdEr e Line as header The contents of the header must be defined via an interface com mand see Section 4 1 GrOSS e Gross weight tArE e Tare weight nEt e Net weight StArLN e Line with CrLF e Line feed blank line F FEEd e Page feed User manual 22013801B 05 08 33 Settings in the menu IND429 IND429xx BBA429 3 8 Diagnosis and printing out of the menu settings DIAGNOS tESt 50 Testing the scale This menu item is only displayed at scales with an analog scale interface External Testing scale with external calibration weight 1 The scale checks the zero point 0 appears in the display The test weight flashes in the display 2 If necessary change the weight value displayed with 619 3 Put the calibration weight on the scale and confirm with E 4 The scale checks the calibration weight put on them b After the test is compl
44. or menu Note 20 Settings can be changed and functions can be activated in the menu This enables adaptation to individual weighing requirements The menu consists of 6 main blocks containing various submenus on several levels Operating the menu Calling up the menu and entering the password The menu differentiates between 2 operating levels Operator and Supervisor The Supervisor level can be protected by a password When the device is delivered both levels are accessible without a password Press E and keep it pressed until COdE appears 2 Press amp gt again The menu item tErMINL appears Only the submenu dEVICE is accessible Press E and keep it pressed until COdE appears 2 Enter the password and confirm with The first menu item SCALE appears No supervisor password has been defined when the device is first delivered Therefore respond to the password inquiry with E when you call up the menu for the first time If a password has still not been entered after a few seconds the scale returns to weigh ing mode Emergency password for Supervisor access to the menu If a password has been issued for Supervisor access to the menu and you have for gotten it you can still enter the menu Press 3 times and confirm with User manual 22013801B 05 08 IND429 IND429xx BBA429 Settings in the menu 3 1 2 Scrolling on one level Activating menu items accepting selection
45. r external storage battery 22 014 056 incl power cable 49 Appendix IND429 IND429xx BBA429 1 Appendix 7 1 Safety checks The device has been tested by accredited inspection bodies has passed the safety checks listed below and carries the relevant test symbols Production is subject to pro duction monitoring by the inspection offices Country Test symbol Standard Canada USA CAN CSA C22 2 No 1010 1 92 n f r IND429 B ig CAN CSA C22 2 No 1010 1 04 f r BBA429 UL Std No 61010A 1 Other countries CB Scheme IEC EN61010 1 2001 EU ATEX prototype test certificate only for IND429xx EN 60079 15 2003 Ex EN 50281 1 1 1998 7 2 EHEDG NSF 50 Tests for utilisation in hygienically sensitive areas Weighing terminal IND429 and compact scale BBA429 have been assessed by the EHEDG European Hygienic Engineering and Design Group and the NSF National Sanitation Foundation Both institutes certify the fulfilment of the hygienic requirements for easy cleaning Hygienic Design Criteria The EHEDG is an association of device manufacturers firms in the foodstuff industry research institutes and health authorities It was founded in 1989 with the aim of pro moting the hygienically faultless manufacturing and packaging of foodstuffs A posi tive expertise of the device by the EHEDG has taken place A corresponding report is available on the
46. s e n the case of certified scales individual sub items of the dISPLAY menu item may not be available or only to a limited extent depending on the respective country e For two range two interval scales resolutions identified with I 1 1 2 are divided into the 2 weighing ranges intervals for example 2 x 3000 d 3 4 2 TARE tare function A tArE Switching on off automatic taring CHAIn tr Switching on off chain tare A CL tr Switching on off automatic clearing of the tare weight when the load is removed from scale Possible settings OFF ON 9 d 3 4 3 ZERO automatic zero update AZM On certified scales this menu item does not appear Switching on off automatic zero update The effective range of the zero update mode 0 5 d 1 0 d 3 0 d can only be set by service technicians in case of IDNet scales Factory setting 0 5 d 3 4 4 RESTART automatic saving of zero point and tare value ON OFF When the Restart function is activated the last zero point and tare value are saved After switching off on or after a power interruption the device continues to work with the saved zero point and tare value User manual 22013801B 05 08 27 Settings in the menu IND429 IND429xx BBA429 3 4 5 FILTER adaptation to the ambient conditions and the weighing type VIbrAt Adaptation to the ambient conditions StAbLE e Very steady and stable environment The scale works very rapidly but is very sensitive to external influen
47. ser manual 22013801B 05 08 IND429 IND429xx BBA429 Introduction 1 Introduction 1 1 Competence EX approval User manual 22013801B 05 08 Safety instructions for the explosion protected weighing terminal IND429xx The device fulfils Device category 3 and is approved for operation in Zone 2 gases and Zone 22 dusts hazardous areas There is an increased risk of injury and damage when used in hazardous areas Special care must be taken when working in such hazardous areas The code of practice is oriented to the Safe Distribution concept drawn up by METTLER TOLEDO A The device accompanying weighing platforms and accessories may only be installed maintained and repaired by authorized METTLER TOLEDO service personnel A The mains connection may only be connected or disconnected by the owner s electrician A For the exact specification please refer to the statement of conformity A No modifications may be made to the terminal and no repair work may be performed on the modules Any weighing platform or system modules that are used must comply with the specifications contained in the installation instructions Non compliant equipment jeopardizes the safety of the system cancels the Ex approval and renders any warranty or product liability claims null and void A The cable glands must be tightened so that a strain relief of gt 20 N per mm cable diameter is ensured A When connecting external devices
48. symbol NET appear 2 Weigh the weighing sample and read print out the result 3 Place the second container or packaging material on the scale and press 619 again The total weight on the scale is saved as the new tare weight The zero display appears 4 Weigh the weighing sample in the second container and read print the result b Repeat the last two steps for other containers Dynamic weighing With the dynamic weighing function it is possible to weigh restless weighing samples such as live animals If this function is activated the symbol 3 appears in the dis play With dynamic weighing the scale calculates the mean value from 56 weighing oper ations within 4 seconds Prerequisite AVErAGE MAnuAL is selected in the menu The weighing sample must be heavier than 5 scale divisions 1 Place the weighing sample on the scale and wait until it has stabilized 2 Press amp gt to start dynamic weighing During dynamic weighing horizontal segments appear in the display and the dynamic result is then displayed with the symbol 3 Unload the scale to be able to start a new dynamic weighing operation Operation IND429 IND429xx BBA429 With automatic start 2 6 2 7 Prerequisite AVErAGE gt AUtOis selected in the menu The weighing sample must be heavier than 5 scale divisions 1 Place the weighing sample on the scale The scale starts the dynamic weighing automatically During dynamic weigh
49. ting whether and after which time the background lighting is to be switched off Scales with a storage battery switch the background lighting off automatically by default when no action takes place at the scale for approx 5 seconds Possible settings OFF switched off 5 sec 10 sec 30 sec 1 min ON switched on Notes e This menu item is accessible without a Supervisor password e The time specifications are approximate values User manual 22013801B 05 08 29 Settings in the menu IND429 IND429xx BBA429 3 6 2 ACCESS password for Supervisor menu access SUPErVI ENtEr C rEtYPE C Password entry for Supervisor menu access Request to enter password gt Enter the password and confirm with Request to repeat the password entry gt Enter the password again and confirm with E Notes e The password can consist of up to 4 characters e The key must not be part of the password It is required for confirming the password e The key may only be used in combination with another key e f you enter an impermissible code or make a typing error in the repetition COdE Err appears in the display 3 6 3 RESET resetting terminal settings to the factory settings SUrE Confirmation inquiry e Reset terminal settings to the factory settings with e Do not reset the terminal settings with 619 3 7 Configuring interfaces COMMUNICATION
50. ttery The operating life during storage battery operation differs depending on the intensity of use the configuration and the connected scale The following approximate values apply with activated background lighting and with standard RS232 interface Scale Conditions Duration Scale with 1 DMS weighing cell 10 96 operating time 120h e g BBA429 90 96 power off mode Continuous operation 12h Scale with 4 DMS weighing cells 10 operating time 90 h 9096 power off mode Continuous operation 9h K line 10 operating time 70h 9096 power off mode Continuous operation 7h Any additional optional equipment reduces the operating life correspondingly 6 1 3 IND429 IND429xx weighing terminal dimensions 289 129 180 188 Dimensions in mm 46 User manual 22013801B 05 08 IND429 IND429xx BBA429 Technical data and accessories 6 1 4 6 1 5 User manual 22013801B 05 08 BBA429 compact scale dimensions 216 A 432 2 Y d Dimensions in mm Model A B C D E F Interface connections The device can be equipped with a maximum of 2 communication interfaces The following combinations are possible COMI COM2 Standard RS232 Standard RS232 RS232 RS232 Standard RS422 485 RS422 485 RS232 Standard Ethernet RS232 Ethernet Standard USB RS232 USB St
51. z 300 mA e IND429xx weighing terminal Rated voltage 230 VAC 10 47 63 Hz 300 mA e BBA429 compact scale Rated voltage 100 240 VAC 47 63 Hz 300 mA Storage battery operation Supply at device 24 VDC 1 0 A If the supply voltage is interrupted the scale switches automatically over to storage battery operation For operating life see Section 6 1 2 Ignition protection type IND429xx to IEC 60079 15 Ambient conditions Interfaces e Hazardous area Zone 2 Device category ll 36 EEx nA II TA Temperature range 10 C 40 C 14 F 104 F e Hazardous area Zone 22 Device category Il 3D IP66 T 70 C e Application in interiors e Height up to 2 000 m e Temperature range Class Ill 10 40 C 14 104 F e Temperature range Class Il 0 40 C 32 104 F e Installation overvoltage category Il e Pollution degree 2 e Relative humidity up to max 80 non condensing e RS232 interface integrated e further optional interface possible Technical data for analog scales For technical data of the analog scales to be connected to IND429 IND429xx please refer to the IND4x9 BBA4x9 installation instructions For technical data of the weighing platform used at BBA429 please refer fo the PBA430 operating instructions User manual 22013801B 05 08 45 Technical data and accessories IND429 IND429xx BBA429 6 1 2 Operating life with storage ba