Kane Kane_455_Quick_Reference_Guide Boiler Manual
Contents
1. displays to an extra decimal place PS UNITS mbar mmH O Pa kPa PSI mmHg hPa InHO LET BY Set duration of let by test in minutes Default 1 minute TIMES STABIL N Set duration of stabilisation in minutes Default 1 minute TIGHTN S Set duration of tightness test in minutes Default 2 minute REPORT COMB N Stored combustion tests VIEW DEL ALL or EXIT max 99 tests oe PRESSURE Stored pressure tests VIEW DEL ALL or EXIT max 20 tests Feed TIGHTN S Stored let by and tightness tests VIEW DEL ALL or EXIT 20 tests i TEMP Stored differential temperature tests VIEW DEL ALL or EXIT 20 tests Sy ROOM CO Stored room CO tests VIEW DEL ALL or EXIT max 20 tests SCREEN CONTRAST CONTRAST Factory setting is 04 setting Factory setting is 04 04 Enables users to customise the parameters on the AUX display User can set any parameter on lines 1 2 3 and 4 HEADER Sets printout header 2 lines 20 characters per line SERVICE CODE Password protected for authorised service agents Leave set to 0000 To EXIT EACH Sub MENU select EXIT To EXIT the MENU move the rotary switch to any position other than Menu Any changes that have not been entered will be ignored 12 Printouts bk AG 1 YOUR COMPANY NAME amp PHONE NUMBER HERE TEST i DATE 13 05 88 TIME 12 60 68 COMBUSTION FUEL NAT GAS OZ z J Coz 4 8 8 CO ppm 12 FLUE TL Doel INLT TL 17 2 NETT C KK EFF
2. LC 96 3 LOSSES Lt XHIR 4 34 8 CO COe H 8001 PRS mBAR H Mu Customer E WWW WWW Appliance Ref K455 1 6 YOUR COMPANY NAME amp PHONE NUMBER HERE PRESSURE LOG 4 TIME 12 56 15705708 PRS MBAR 6 25 Customer Appliance Ref KAES 1 0 YDUR COMPANY NAME amp PHONE NUMBER HERE LOG o g4 TIME 11 55 15 85 08 Let By Test PRS_1 mBAR PRS_2 mBAR LET BY MINS Tightness Test PRS_i m5AR PRS_2 MBAR 4PRS MBAR STABIL N MINS z TIGHTN S MINS 2 66 CRW WW WWW WWW WWW Customer Appliance WS RS SG RS SS WS SS SS SS BR DS Ref K455 1 6 YOUR COMPANY NAME amp PHONE NUMBER HERE DIFF TEMP LOG 3 TIME 12 10 15705708 68 1 Appliance Ref bb ENN 1 YOUR COMPANY NAME amp PHONE NUMBER HERE ROOM CO TEST LOG i TIME 12 50 15705708 TEST KA Fa HM 1 2 3 4 2 6 7 8 9 G 1 12 13 i4 E MAXIMUM CO Customer Appliance TUTTY A 77 Supplied By www heating spares co Tel 0161 620 6677
3. seconds to log a differential temperature report ROOM CO TESTING select Room CO for CO investigations Please refer to user manual ROOM CO display ROOM CO Duration of this test is variable from 0 to 30 minutes as per BS7967 COp 00 Real time CO reading ppm TEST 14 Test 00 start To stop the Room CO test press the PUMP button LOG 01 The complete Room CO test is automatically stored as a log number OTHER DISPLAY CODES PO Pump Off OC Open Circuit on temperature input FOR BEST PRESSURE SENSOR ACCURACY 1 Switch the analyser on for 5 minutes to let the temperature stabilise 2 Zero the pressure sensor when the analyser in the exact position that it will be used TO FULLY CHARGE NiMH RECHARGEABLE BATTERIES The analyser must be switched on Connect the charger and switched it on charging indicator illuminates Switch the analyser off the display will show BATTERY CHARGING The BAT status number of fully charged NiMH batteries is typically 70 FON 11 USING TRE MENU select Menu on the rotary switch and navigate using the function buttons A ous 7 soen MAIN MENU SUB MENU OPTIONS COMMENTS ey NEC gt G EfN nett efficiency EfG gross efficiency EfC condensing efficiency e SET TIME Uses Military time 7am 07 00 7pm 19 00 SETDAaTE Uses DD MM YY forma PRESSURE SMOOTH OFF normal response ON slower damped response ey RESOLVE LOW normal HIGH
4. This Document Has Been Provided By AHEATING SPARES Please Visit www heatingspares co or call us on 0161 620 6677 For Spares at Discounted Prices KANE455 QUICK REFERENCE GUIDE Be Infra red emitter and torch light Menu controls Scroll up down Enter Function buttons x 4 See below for details Rotary switch _ Particle filter lt _ Water trap Battery charging indicator Analyser Connections E SN e Flue Gas Inlet see diagram overleaf see diagram overleaf PUMP ON OFF Turns the pump ON OFF Turns the analyser ON OFF Hold button to zero pressure SEND ENTER BACKLIGHT Send readings to printer Switches backlight amp torch light Press button for 1 second ON OFF Send readings to memory Hold button down for 2 secs Stock No 18839 Supplied By www heating spares co Tel 0161 620 6677 This Document de CN at By db BR Please Visit Ee ege Ae or call us on i connection FI T1 ue probe e Baien charger Inlet seer el Pressure connection P1 Rubber Bung Flue Gas Inlet Pressure connection P2 differential Fit Spigot to Hose before connecting to Analyser Supplied By www heating spares co Tel 0161 620 6677 Note Or BEFORE USING ANALYSER CHECK THE FOLLOWING Particle filter is not dirty inside Water trap and flue probe hose are empty of water Water trap and rubber bung ar
5. e fitted correctly to the analyser Flue probe hose is connected properly to the flue gas inlet Flue probe temperature plug is connected into T1 temperature connection Please read the Safety Warnings in the User Manual FRESH AIR PURGE Position the flue probe in fresh air then press the On Off button The analyser auto calibrates for approximately 90 seconds When complete select Ratio on the dial In fresh air the CO reading Oppm Select O Eff on the dial In fresh air the O reading 20 9 select Status on the dial to view the following STATUS display BAT 59 Battery status If less than 20 recharge or replace see section 10 11 46 29 Current time Can be set via the Menu see section 11 15 05 08 Current date Can be set via the Menu see section 11 CAL 283 Number of days until next check and calibration is required Boiler inlet air temperature can either be a Set automatically by the flue probe during the fresh air purge b Continuously measured if a thermocouple is plugged into the T2 socket COMBUSTION TESTS select Ratio on the dial to check that the analyser is set for the correct fuel To change fuel select MENU SETUP SET FUEL then use scroll and enter See section 11 Position the flue probe as per the boiler manufacturer s instructions typically the tip of the flue probe is inserted to the centre of the flue The readings will stabilise af
6. ectors and manometer hose connect to P1 for single pressure or P1 and P2 for differential pressure PRS display PRESSURE Defaults to smoothing off on start up Can be changed via Menu P 0 04 Defaults to low resolution on start up Can be changed via Menu mbar Pressure units can be changed via Menu 12 56 29 Displays time to enable manually timed tests Press SEND to print a pressure test Also sends to PC if Bluetooth fitted Hold SEND for 2 seconds to log a pressure report 5 LET BY and TIGHTNESS TESTING Also see section 9 select Tightness The pump stops Press the PUMP button to auto zero the pressure sensor Select yes or no for the let by test by using A or V then press a Connect from the test point to P1 using a black connector and manometer hose Adjust the gas pressure as you would with a U tube manometer Press CR to start either the let by test or the stabilisation period LET BY Let by test display P1 10 35 Pressure at the start of the let by test P2 10 35 Realtime pressure reading TIME 59 Let by default time is 1 minute Can be changed via Menu When complete adjust the gas pressure if necessary then press G to start the stabilisation period STABIL L N Stabilisation display P1 20 00 Real time pressure reading mbar TIME 59 Stabilisation default time is 1 minute Can be changed via Menu Wh
7. en complete adjust the gas pressure if necessary then press 44 to Start the tightness test TIGHTN S Tightness test display P1 20 33 Pressure at start of tightness test P2 20 33 Real time pressure reading TIME 119 Tightness default time is 2 minute Can be changed via Menu When complete the display will show LOG 06 Let by and tightness test are automatically stored as a log number P1 20 33 Pressure at start of tightness test P2 20 26 Pressure at end of tightness test PRINT d The test can be printed immediately or later from the memory Note The analysers memory can store up to 20 tightness tests Tightness tests are logged automatically therefore the tightness section of the memory will be full after the 20 tightness test is complete Before the 21 tightness test can be performed the tightness section of the memory must be cleared To do this select MENU REPORT TIGHTN S DEL ALL YES then press oa DIFFERENTIAL TEMPERATURE select Diff Temp to measure flow return and differential temperatures DIFF TEMP display TEMP Pump automatically switches off when dial is moved to Diff Temp Tic 60 1 Use the T1 connection for the flow temperature sensor T2c 47 0 Use the T2 connection for the return temperature sensor Afc 13 1 Real time temperature difference Press SEND to print a differential temperature test Also sends to PC if Bluetooth fitted Hold SEND for 2
8. ter 60 seconds assuming the boiler conditions are stable The rotary switch can be used to display the following information RATIO display NAT GAS Fuel type can be changed via Menu see section 11 R 0 0001 CO CO z ratio COP 12 Carbon Monoxide ppm CO2 8 8 Carbon Dioxide Press SEND to print a full combustion test Also sends to PC if Bluetooth fitted Hold SEND for 2 seconds to log a full combustion report O2 EFF display O2 5 4 Oxygen left after combustion Should be 20 9 in fresh air TFe 55 1 Flue temperature C Tlc 17 2 Inlet temperature Normally set by flue probe during fresh air purge EfC 98 3 Condensing boiler efficiency EfC Can be changed via Menu Press SEND to print a full combustion test Also sends to PC if Bluetooth fitted Hold SEND for 2 seconds to log a full combustion report AUX display O2 20 9 The default AUX auxiliary display is shown COP 00 The parameters on lines 1 2 3 and 4 can be set independently 11 55 02 To customise the AUX display select MENU SCREEN AUX BAT 59 They remain the AUX parameters until changed again by the user Press SEND to print a full combustion test Also sends to PC if Bluetooth fitted Hold SEND for 2 seconds to log a full combustion report PRESSURE TEST Also see section 9 select Prs The pump stops Press the PUMP button to auto zero the pressure sensor Using the black conn