Contents
1. 6 FANUC SUPPLY SERIES SIX PROGRAMMABLE CONTROLLERS 123 VDC INPUT CPU POWER i GFK 0065 Source Voltage 100 to 150 V dc Output Voltage 5 12 12 V dc GENERAL DESCRIPTION The 125 V dc Input CPU Power Supply Module used in the Central Processor Unit CPU is available to be used with a power source from 100 to 150 V dc The features and benefits of this summarized in Table 1 The 125 V dc Input CPU Power Supply Module provides regulated 12 12 and 5 dc voltages to the rack backplane The input or source voltage is applied to terminals on the front panel then routed through a switch and fuse to a switching power supply For a given load the input power drain remains essentially constant The power supply is protected against polarity reversal of the dc Input The module provides electromechanical relay contacts for connection to user indicators or any device to be activated during an alarm condition The module also module are provides a voltage regulator for an opt ional auxiliary battery that provides battery back up of Complementary Metal Oxide Semiconductor CMOS memory contained in the processor rack A Keyswitch mounted on the front panel is used to select either the RUN or the STOP mode for the processor a second Keyswitch allows the user to protect the contents of the processor memories by placing them in a READ ONLY mode The same key operates both Keyswitches Refer to T
2. Figure 2 Be sure to connect the 18 pin molex connector P1 to the power supply Attach the wire clamp on the upper stud of the power supply frame or if there is a clamp already there wrap the wires in it 11 12 13 14 15 Slide the power supply into the rack being careful not to damage the wires When the power supply is al the way in turn the thumbscrews clockwise until they lock in Remove the plastic cover on the lower portion of the power supply and attach the DC wires as well as the battery and alarm wires as they were on the original supply Refer to Step 6 and Figure 3 Replace the plastic cover Verify that the DC input lines are of the correct polarity before applying power An inadvertant reversal of input polarity will cause the supply to draw excessive currents and may blow the internal fuse 2A slo blow which must then be replaced before proper operation can be resumed Restore system power Turn on the CPU unit Check to see if the POWER light is on If it is turn on the rest of the system and resume normal operation If the POWER light does not come on the power supply may be bad source voltage may not be turned on or there may be other problems within the rack Please call your local authorized GE Fanuc Automation Distributor or Sales off ice for assistance GFK 0065 125 V dc Input CPU DPU Power Supply Module 5 WIRES FROM THE BACK PLANE WILL BE MARKED TERRAS P STB
3. Refer to Figure 2 Chassis Ground Terminal 18 Pin Connector Connects signal cable from rack backplane Front Panel Connector Block Figure 3 Power Switch Fuse Refer to FIGURE 1 7 MEMORY PROTECT Keyswitch 8 POWER Light On Off USER ITEMS The voltage levels of all three DC outputs G12V 12V 5V are within tolerance At least one of these voltage levels is too low GFK 0065 125 V dc Input CPU DPU Power Supply Module 4 10 INSTALLATION Continued At the top and bottom of the power supply there are 1 4 turn thumbscrews To loosen turn the thumbscrews approximately 1 4 turn counterclockwise Grasp the thumbscrews and gently pull outward Be careful not to damage the internal wiring while pul ing the supply out Locate the wires that extend from the back of the rack to the terminal on the power supply These wires should be labeled or stamped with their location the circuit boards have wire locations stamped on them Remove these wires There is also a plastic wire clamp holding these wires in place Detach this from the frame if there is not a similar item on the replacement power supply or cut the clamp if there is one on the new supply Remove the 18 pin P1 molex connector that is on the narrow board in the front part of the power supply The power supply should now be completely detached from the rack Take the replacement power supply and attach the wires as shown in
4. 9 OR 5V 9 PSTB 7 OR OV 8 PSTB 6 OR 12V 6 PSTB 5 OR 12V 5 PSTB 4 OR 12V 4 H SEER fj LLL LLL A K AAAA 12V GND H a8 12V LLL OV COM NEG Ay 5V POS TO BACKPLANE MOLEX i P FIGURE 2 POWER SUPPLY EXTERNAL WIRING DIAGRAM If a memory auxiliary battery is used the circuit connecting it to this module should be isolated from the rest of the system If this CAUTION is not observed the battery could be short The user devices connected to each set of Alarm terminals on this module should present a resistive load drawing no more than one amp of current at no greater than 115 V ac 28 V dc Failure to observe this CAUTION circuited may result in damage to the circuit board The alarm contacts consist of two sets of normally opened and normal iy closed contacts The NOTE terminals marked 1 NO and 1 NC are associated with Alarm During normal operation the Type No 1 the terminals marked alarm relays are energized 2 NO and 2 NC with Alarm type No 2 Refer to Series Six Plus Users Manual GEK 96602 for further information on Alarm Nos 1 and 2 During an alarm condition the contacts marked INO and 2NO open and those marked 1NC and 2NC close GFK 0065 125 V dc Input CPWDPU Power Supply Module Ref PC S6 84 0246 AUXILIARY BATTERY l O RELAY contacts 4 Com O Fos ISOLATED DC INPUT 200 NEG 100 TO 150 VD
5. C CONTACT RATING FOR DC INPUT TERMINALS IS 125V DC 300 MA RESISTIVE FIGURE 3 FRONT PANEL TERMINAL BLOCK ORDERING INFORMATION Module Part Number 125 V dc Input CPU Power Supply Module IC600PM546 The UL symbol on the nameplate means the product is listed by Underwriters Laboratories Inc UL Standard No 508 Industrial Control Equipment subsection Electronic Power Conversion Equipment For further information contact your local GE Fanuc Automation Sales office GE FANUC AUTOMATION NORTH AMERICA INC CHARLOTTESVILLE VIRGINIA MARCH 1987
6. C outside of the rack Storage Temperature 20 C to 80 C Humidity 5 to 95 non condensing INSTALLATION These steps define the procedures to be followed when a power supply is to be replaced on a Series Six or Six Plus CPU rack The tools needed are a regular screwdriver Phillips screwdriver and a 5 16 wrench or nut driver 1 Stop the system by switching the top key on the CPU to STOP 2 Switch off all units in the system including the user s power supplies 3 Remove all power from the system preferably at the source i e throw the main circuit breaker for the system 4 Locate the power supply to be changed The power supply is in the far right side of the CPU rack 5 Remove the plastic cover on the lower portion of the power supply to be replaced and using a volt meter make sure there is no dc power present 6 Take note of the location and color of the dc wires and then remove them Also remove Auxiliary battery and or Alarm connection s noting location color and polarity for correct replacement GFK 0065 125 V dc Input CPU DPU Power Supply Module SIDE VIEW 3 Ref PC S6 84 0243 Ref PC S6 84 0244 PROCESSOR POWER 125V DC SUPPLY 2A MAX INPUT a LOGIC N PWR ON PROC a OQ STOP MEMORY PROTECT CONTACT RATING 125V DC 300 MA RESISTIVE Internal Terminal Strip FRONT PANEL 6 CPU RUN STOP Keyswitch
7. able 2 for the CPU Power Supply module specifications The 125 V dc input CPU Power Supply Module may be used in place of a 115 230 V ac or a 24 V dc Input CPU Power Supply Module in an existing rack if 125 V dc input is desired TABLE 1 FEATURES AND BENEFITS FEATURES BENEFITS Uses dc input power source Can be used in any CPU rack Provides electromechanical relay con tacts for alarm indications Contains voltage regulator for aux iliary battery Extends power source compatibility to 125 V dc systems Reduced spare parts inventory Activates user supplied power indi cators External battery back up of CMOS memory GFK 0065 125 V dc Input CPU DPU Power Supply Module 2 Table 2 SPECIFICATIONS Input 100 to 50 V dc 2 A max output Total power 1 5 V dc 16 5 A max from all 2 12 V de 1 5 A max outputs 3 12 V dc 1 0 A max must be 4 12 V dc 2 0 A max less than 90 watts Output number 4 rated at 12 0 V dc nominal when output supply currents are I 5 V dc 8 0 A 2 12 Vdc 1 0A 3 12 V dc 0 5 A 4 12 V dc 1 0 A Allowable Power Interruptions 4ms minimum at 100 V dc line Noise Immunity ANSI C37 90A Meets requirements of NEMA KS 2 230 and Altitude Up to 10 000 feet 3 000 meters above sea level Auxiliary Battery Input 8 28 V dc 12 46 x 9 00 x 2 75 inches 317 x 229 x 70 mm Dimensions Operating Temperature 0 C to 60
Download Pdf Manuals
Related Search
Related Contents
Philips SBCHC8580 Wireless HiFi Headphone Thermo Scientific Niton XL2 GOLDD Tube-Based X Bojan Godina Unsichtbare Religion des Subliminalen Trust SoundForce Vivo 2.1 Cobra Coupé Daytona (Highland Daytona Racing) Kühl-Gefrier-Kombination Projetor Manual do usuário [U4.36.06] Opérateur GENE_MATR_ALEA Phaser 7500 Quick Use Guide Copyright © All rights reserved.