Home

General specifications

image

Contents

1. NOTICE Before operating the product read the user s manual thoroughly for proper and safe operation f this product is for use with a system requiring safeguards that directly involve personnel safety please contact the Yokogawa sales offices This product is not constructed to be explosion proof Subject to change without notice Ed 03 b Copyright 2003 Printed in Japan 402 YG Phone 1 770 253 7000 Fax 1 770 251 2088 Phone 31 33 4641806 Fax 31 33 4641807 Phone 65 62419933 Fax 65 62412606 RS 12E MASTER YOKOGAWA New Input Output Modules for the DAQMASTER Series Introducing Seven New I O Modules for the DAQMASTER Series The DAQMASTER Series continues to evolve offering you higher measurement performance e Input Modules Name Model Number of Shortest Measurement channels Interval Description Built in bridge resistance of 120 Q MX112 B12 M04 Strain Input Module MX112 B35 M04 4 100 ms MX112 NDI M04 4 Wire RTD and Resistance Input Module MX110 V4R M06 6 24 V Digital Input Module MX115 D24 H10 10 jaime Built in bridge resistance of 350 Q For connection with an external bridge head and strain gauge type sensor NDIS connector 24 V logic Vth 12 V 4 Wire RTD and Resistance Input Module 24 V Digital Input Module Removable Terminals Strain Input Modules 772068 772069 for MX112 B12 M04 for MX112 B35 M04 built in brid
2. 0 05 of rdg 3 digits 0 1 of rdg 15 digits 0 01 Q 0 0 to 2000 02 0 05 of rdg 3 digits 1 To be determined at the measurement current of approximately 10 uA and within the range of 200 mV selecting the measurement interval but the relationship between the integral time and the measurement interval i The threshold level is 0 1 V i differs depending on the modules If measured values are inconsistent consult the user s manual for guidance on i how to select a measurement interval that will yield a sufficient integral time 2 The Pt500 resistance table is Pt100x5 and the Pt1000 resistance table is Pt100x10 Note If temperature thermocouple resistance or strain measurements are taken by the MX110 or MX112 at an integral time of 1 67 ms the measured values may be susceptible to inaccuracies due to power supply frequency noise If this is the case set the integral time to 16 67 ms or longer for a power supply frequency of 60 Hz or 20 ms or longer for a power supply frequency of 50 Hz On DAQMASTER the integral time is automatically set when e New Option DS Added for the MX100 Main Module e PC Software Products Dual Save Function The following shows the availability and requirements of specific PC software products for use with the new input output modules The following three functions are now available MX100 Standard Software MX180 Simultaneous upgrade with new input output modules R1 02
3. 0 1 of rdg 6 C 0 1 C RJC accuracy 200 0 to 800 0 C not included 200 0 to 1100 0 C O ting C aang C SO 200 to 100 C 200 to 100 C res ae aie see 500 0 to 400 0 C 0 05 of rdg 0 7 C 0 1 of rdg 5 C 0 0 to 1300 0 C 0 05 of rdg 0 7 C 0 1 of rdg 3 5 C 0 0 to 2315 0 C 0 05 of rdg 1 C 0 1 of rdg 7 C KpvsAu7Fe 0 0 to 300 0K 0 05 of rdg 0 7K 0 1 of rdg 3 5K 38 C SC Pt100 200 0 to 600 0 C 0 059 0 19 1 5 P1100 200 0 to 550 0 C 0 05 of rdg 0 3 C 0 1 of rdg 1 5 C Pt00 high resolution 140 00 to 150 00 C 0 05 of rdg 0 3 C 0 1 of rag 1 5 C 0 01 C RTD sPt00 high resolution 140 00 to 150 000 005 Of rdg nea ooro measurement __Ni00SAMA 200 0 to 250 0 C current 1 mA Ni100 DIN 60 0 to 180 0 C s A unas 15 Ni120 270 0 to 200 0 C 0 05 of rdg 0 3 C 0 1 of rdg 1 5 C Pt50 200 0 to 550 0 C Cu10 GE 200 0 to 300 0 C Cu10 L amp N 200 0 to 300 0 C Cu10 WEED 200 0 to 300 0 C 0 1 of rdg 1 5K Threshold level accuracy 0 1 V 1 KQ or less ON 100 kQ or more OFF parallel capacity is 0 01 uF or less 0 1 0 1 of rdg 2 C 0 2 of rdg 5 C Special Input Ranges that can be used in MKLOGGER Rated measurement Measurement accuracy Measurement accuracy Maximum Input Type p resolution range integral time 16 67 ms or more integra
4. Number of measurement points 10 scanning of 10 channels with one A D Input method Floating unbalanced input insulation between channels Note that RTD is common among b terminals A D resolution 20000 6000 16 bit A D is used Measurement interval 100 200 500 ms 1 2 5 10 20 30 60 s A D integral time 1 67 16 67 20 36 67 100 200 ms AUTO A D integral time is determined by measurement intervals Measurement Ranges and Accuracies Rated Measurement accuracy Measurement accuracy Maximum Input Type resolution measurement range integral time 16 67 ms or more integral time 1 67 ms 1 digit 20 mV to 20 mV 0 05 of rdg 5 digits 0 1 of rdg 25 digits 60 mV to 60 mV 10 uV 0 05 of rdg 2 200 mV 200 mV to 200 my 09 of rdg 2 digits Voltage 2Vto 2V_ 0 05 of rdg 5 digits 0 1 of rdg 10 digits 6V to 6 V 20 V to 20V_ 0 05 of rdg 2 digits 100 V 100 V to 100 V OO OUR 0 05 of rdg 1 C 0 1 of rdg 4 C 0 0 to 1760 0 C However R S However R S 0 to 100 C 3 7 C 0 to 100 C 10 C 100 to aE ae 100 to oe B 400 to 600 C 2 B 400 to 600 C 7 OOo 1820 0 C Less than 400 C accuracy is not Less than 400 C accuracy is guaranteed not guaranteed 0 05 of rdg 0 7 C 0 1 of rdg 3 5 C K 200 0 to 1370 0 C However 200 to 100 C However 200 to 100 C Thermocouple 0 05 of rdg 1 C
5. Number of channels 10 Insulation resistance NDI is not applicable Measurement interval 10 50 100 200 500 ms 1 2 5 10 20 30 60 s Between an input terminal and ground 20 MQ or more 500 VDC Input resistance Approximately 200 kQ between and terminals Withstanding voltage NDI is not applicable Maximum input voltage 50 VDC Between an input terminal and ground 2300 VACrms 50 60 Hz for one minute Minimum detection pulse width two times the measurement interval or more Between channels 50 V peak or less Input threshold level Off for 6 V or less ON for 16 V or more Power consumption Approximately 3 W Insulation resistance 20 MQ or more between an input terminal and ground 500 VDC Calculations related to strain measurement performed on the main module Withstand voltage 2300 VACrms 50 60Hz between an input terminal and ground one minute Initial balance The initial balance value is measured and set as the 0 point Power consumption Approximately 1 5 W Initialization of the initial balance value Returns the initial balance value to 0 Reloading of the initial balance value Reloads the saved initial balance value Eight Channel Medium Speed Analog Output Module MX120 VAO M08 When using Yokogawa s dedicated software MX100 standard software or MXLOGGER the Number of output points 8 initial balance value is stored in the PC software project file Reloading is performed by reading Output types DC voltage
6. 0 50 C Operating humidity range 20 80 RH for 0 40 C 10 50 RH for 40 50 C Rated power supply voltage AC power supply 100 240 VAC Range of operating power supply voltage AC power supply 90 250 VAC Power supply frequency 50 Hz 2 60 Hz 2 Power consumption Up to approximately 70 VA when six modules are used Installation method ie ee and panel mount using the DIN rail Supported standards SSA eee CSA22 2 No 1010 1 eae eee category Overvoltage category Il Degree of pollution 2 Obtained UL61010B 1 CSA NRTL C CE EMC directive EN61326 EN61000 3 5 EN61000 3 3 EN55011 Class A Group 1 Low eee EN61010 1 eee Measurement category Il Degree of pollution 2 AS NZS 2064 Class A Group 1 Model Specific Specifications e Main Module MX100 Main functions Control of the power supply and input output modules communication with the PC storage of data on the CF card during a communication failure Number of maximum connectable input output modules 6 arbitrary for six modules or less Up to three types can be set per system multi interval Types of measurement intervals are 10 50 100 200 500 ms 1 2 5 10 20 30 60 sec Note that configurable measurement intervals differ depending on modules Transfer interval of measured data to the PC Minimum 100 ms DO interval update interval 100 ms not synchronized with timing every measurement interval of 100 ms First order lag filter Th
7. 67 ms Common mode voltage 600 VACrms 50 60 Hz reinforced double insulation Common mode rejection ratio CMRR 120 dB or more when the integral time is 16 67 ms or more 80 dB or more when the integral time is 1 67 ms 50 60 Hz 0 1 500 Q imbalance between the minus measurement terminal and the ground Common mode voltage between channels 120 VACrms 50 60 Hz Noise rejection Rejection by an integrating A D converter and the use of low pass filters Input resistance 10 MQ or more for the DC voltage of 200 mV range or less and also for the thermocouple range Approximately 1 MQ if the DC voltage is in the 2 V range or more Insulation resistance 20 MQ or more between the input and the ground 500 VDC Input bias current 10 nA or less except for the burn out setting Withstand voltage 1000 VAC 50 60 Hz between input terminals one minute 3700 VAC 50 60 Hz between an input terminal and the ground one minute Input signal source resistance 2 kQ or less for DC voltage and thermocouple 10 Q or less per cable for RTD 50 Q or 100 Q systems 1 Q or less per cable for RTD 10 Q or 25 Q systems Thermocouple burn out Checking of the burn out at a detection interval specified for each measurement interval Parallel capacity during RTD 0 01 uF or less Power consumption Approximately 1 2 W External dimension Approximately 57 x 131 x 150 mm including the terminal cover Weight Appr
8. NC lt Mounting of Racks or Panels Using the DIN Rail gt Use the DIN rail for mounting on racks or panels The DIN rail can be easily attached using the dedicated bracket Two brackets come standard with the base plate MX150 Bracket for mounting the DIN rail High Speed Multi Channel Capability The table below provides reference information on the maximum number of measurable channels in relevant measurement intervals when using Yokogawa s proprietary software PC Software Number of Necessary Modules example Maximum aen number of Measurable objects MX100 Main Module Four Channel High Speed Ten Channel Medium Speed interva measurable Standard MXLOGGER Universal Input Module Universal Input Module channels Software MX100 MX110 UNV H04 MX110 UNV M10 10ms 24channets bewo J oooi S e d y 50ms en eaea Vv SOSO 50ms _ 120channels Devoto 5 J a y O 100ms 60channels pevmomtoi v ys i o o o f e O 100ms 300chames Devoto y 5 o 200ms 500chames pevmomtoi s o0 5 500ms eochames Devoto S 0 o _ _ _ 1000 ms 1200channes DevmoRto s o 120 4 measurement that support is possible measurement that support is not possible lt _ EN lt ee lt ea e The relationship between measurement intervals and the number of channels largely depends on the performance of the PC The actual pe
9. acquisition It is equipped with a power supply an Ethernet port and a CompactFlash card slot One main module can accommodate up to six input output modules The user can choose up to six moduels of any type Data Backup Time by CF Card Size Note Minutes hours days are approximate Number of saved channels Ethernet Port For communication with the PC Automatic recognition of 100Base TX or 10Base T Measurement interval 32 M 128 M 512 M Da 35days 15 days 4 5 days 18 5 days 75 5 days 18 days 75 5 days 303 days Aa 7 5 days 31 5 days 7 5 days 31 5 days 126 days on 2 5 days 12 5 days 12 5 days 50 days CF CompactFlash Card Slot With the CF Card measured data is saved to the card if communication with the PC is interrupted Since the card provides data backup you do not have to worry about the possible loss of data even if the MX is configured for PC based measurement 2s Input Output Modules MxX110 MX115 MX125 E Four Channel High Speed Universal Input Module E Ten Channel Medium Speed Universal Input Module MX110 UNV H0O4 MX110 UNV M10 Note All I O modules are fitted with a swing up terminal cover Shortest measurement interval 10 ms Maximum number of input channels 4 Shortest measurement interval 100 ms Maximum number of input channels mi tt channels Mixed input of DC voltage thermocouple RTD and digital input possible Please note that the shortest
10. measurement interval for temperature is 50 ms for this module E Ten Channel High Speed Digital Input Module MX115 D05 H10 If a single unit consists of this module only measurement of 60 channels 10 ms is possible Most suitable for measurement of digital input signals at many points inexpensively Shortest measurement interval 10 ms Maximum number of input channels 10 channels Digital input dedicated module 10 channels Mixed input of DC voltage thermocouple RTD and digital input possible E Ten Channel Medium Speed Digital Output Module MX125 MKC M10 For use of alarm outputs etc Shortest output interval 100 ms Maximum number of output channels 10 channels Digital output dedicated module Base Plate MxX150 The main module and input output modules are connected by means of connectors on a base plate For one input output module lt Using the Base Plate for Six Input Output Modules gt Although the position for the main module is fixed input output through modules can be configured in any position using the module connectors One to six modules can be used Connector covers 772066 are available for vacant slots Modules and Terminals lt Attachable Detachable Terminals gt All input terminals can be attached detached If the user provides multiple terminals there is no need to perform rewiring every time measurement is carried out E Four Channel High Speed E
11. 5 Cu100 at 0 C a 0 00425 Pt25 Cu10 GE high resolution Cu10 L amp N high resolution Cu10 WEED high resolution Cu10 BAILEY high resolution Reference junction compensation External internal switchover can be performed for each channel Reference junction compensation accuracy During the measurement of 0 C or more and during the input terminal temperature balance Type R S W 1 C Type K J E T N L U 0 5 C Note Internal reference junction compensation of Type B is fixed to 0 C 200 mV DC range or less thermocouple RTD DI non voltage contact 10 VDC continuous 120 VDC continuous Oto 60 mV 0 05 of rdg 20 digits Voltage Supported thermocouple Supported RTD Maximum input voltage Other measurement ranges Normal mode voltage DCV TC DI level 1 2 times of rated range or less 50 60 Hz peak values including signals RTD 100 Q system 50 mV peak RTD 10 25 50 Q systems 10 mV peak Normal mode rejection ratio NMRR When the integral time is 16 67 ms or more 40 dB or more 50 60 Hz 0 1 When the integral time is 1 67 ms 50 60 Hz is not rejected Common mode voltage 600 VACrms 50 60 Hz reinforced double insulation Common mode rejection ratio CMRR 120 dB or more when the integral time is 16 67 ms or more 80 dB or more when the integral time is 1 67 ms 50 60 Hz 0 1 500 Q imbalance between the minus measurement terminal and the
12. Clamp terminal Applicable cable size for connectors 0 08 2 5 mm AWG28 12 Contact mode A contact SPST Update interval output per 100 ms Contact capacity 250 VDC 0 1 A 250 VAC 2 A 30 VDC 2 A resistance load Insulation resistance 20 hee or more 500 VDC between an output terminal and the roun 30 MQ or more 500 VDC between output terminals Withstand voltage 2300 VAC between an output terminal and the ground one minute 2300 VAC between output terminals one minute Power consumption Approximately 2 W when all relays are turned on External dimension Approximately 57 x 131 x 150 mm including the terminal cover Weight Approximately 0 5 kg Others The excitation non excitation switchover and Hold non Hold switchover are available PC Software Specifications e MX100 Standard Software attached to the main module of MX100 for connection with one MX unit Integration Monitor main functions Setting of the basic connection setting of various conditions range interval computation tag monitor display digital trend 32 channels in one group 10 groups logging computation function 60 channels alarm output manual DO etc Viewer main functions Re display of saved data files 32 channels in one group 50 groups data synchronization processing file merge display limited to files that can be merged multi interval supported graph and digital display print etc Calibratio
13. DC between H L continuous Input bias current 10 nA or less Common mode voltage Withstanding voltage Between input terminals DCV or DI range 1000 VACrms 50 60 Hz for one B12 B35 Between channels 30 VACrms 50 60 Hz minute Between an input terminal and ground 250 VACrms 50 60 Hz Between input terminals RTD or resistance range 620 VACrms 50 60 Hz for NDI Between channels 30 VACrms one minute Between an input terminal and ground 30 VACrms Between an input terminal and ground 3700 VACrms 50 60 Hz for one minute the connector shell is connected to earth potential Input signal source resistance 2 kQ or less for DCV range Common mode rejection ratio CMRR NDI is not applicable 10 Q or less per cable for the resistance and RTD ranges common for all 120 dB or more when the integral time is 16 67 ms or more 50 60 Hz 0 1 ranges 80 dB or more when the integral time is 1 67 ms 50 60 Hz 0 1 Allowable parallel capacity 0 01 u F or less when using the resistance or RTD range voltage conversion value given a bridge voltage of 2 V Power consumption Approximately 1 2 W Normal mode rejection ratio NMRR 40 dB or more 50 60 Hz 0 1 when the integral time is 16 67 ms or more Ten Channel High Speed 24 V Digital Input Module MX115 D24 H10 50 60 Hz is not rejected when the integral time is 1 67 ms Input type Level 24 V logic No isolation between channels voltage conversion value given a bridge voltage of 2 V
14. DC current allows mixed voltage and current output the project file Output data Command output manual output Output of set and calculated values and retransmission of measured e Six Channel Medium Speed 4 Wire RTD and Resistance Input Module MX110 V4R M06 values are carried out by commands from the PC Types of measurement DC voltage 4 wire RTD 4 wire resistance DI non voltage contact LEVEL 5 V Retransmission output Scales values measured on input modules in the same unit and outputs them logic Output is continuous even when communications are cut as the operation is Number of measurement points 6 scanning of 6 channels with one A D performed inside the main module Input method Floating unbalanced input isolation between channels You can select to output the previous value the value just prior to the abnormality or the value when M t d ies atstandard ti diti See Note the power was last turned OFF or a preset value when an abnormality occurs such as when easurement ranges and accuracies at Standard operating conditions recovering after the power or communication was cut and the power is ON l Output update cycle 100 ms M t l Input Type Rated measurement e ar Measurement accuracy Se Rated output range Voltage 10 to 10 V current 0 to 20 mA sourcing 4 to 20 mA is output at 1 to 5 V range ms or more integral time 1 67 ms 1 digit output om 20 000 to 20 000 mV 0 05 of rdg 5 digits 0 1 of rag 25 digi
15. Ten Channel Medium Speed Universal W Ten Channel Medium Speed Universal Input Module Input Module Digital Output Module MX110 UNV H04 MX110 UNV M10 MX125 MKC M10 E Ten Channel High Speed Digital Input Module MX115 D05 H10 Plate with clamp terminals with RJC 772063 gt Bl Clamp terminal 772064 MX115 D05 H10 s plate with clamp terminals does not have RJC RJC Reference Junction Compensation Clamp terminal FB 772065 Each terminal can be attached detached Each plate with terminals can be attached detached Each terminal can be attached detached lt Screw Terminal Block gt A separate screw terminal block is available for the MX110 UNV M10 Ten Channel Medium Speed Universal Input Module and the MX115 D05 H10 Ten Channel High Speed Digital Input Module Connection Cable 772062 between input modules and the screw terminal block Detach the plate with clamp terminals from the MX110 UNV M10 or MX115 D05 H10 Then use the connection cable 772062 to connect the input module without the plate to the screw terminal block 772061 The option code NC can be added to the MX110 UNV M10 and MX115 D05 H10 to indicate whether or not the plate with clamp terminals is included at the time of delivery If the user requires only the screw terminal block and not the clamp me terminals please specify either MX110 UNV M10 NC or Screw Terminal Block 772061 The screw terminal block is installed MX115 D05 H10
16. YOKOGAWA PC Based Data Acquisition Unit H i iR www yokogawa com tm and subscribe to Newswave our free e mail newsletter TER A PC based data acquisition system for the future delivering unparalleled performance When combined with Yokogawa s proprietary PC software the MX100 s high speed multi channel capability and high withstand voltage offers the ultimate in measurement power a Fuel Cell Bulletin 04M08B01 00E PC Based Data Acquisition Unit Maximum Performance e Shortest measurement interval of 10 ms high speed measurement of 10 ms on 24 channels or 100 ms on 60 channels is possible e Possible to acquire data from up to 1 200 channels when using Yokogawa s proprietary software e Reinforced insulation between the input terminal and the case handles 3700 Vrms for one minute or 600 Vrms VDC continuous e Mixed use of three types of measurement intervals is enabled within the system measurement intervals are set for each module Ease of Use By configuring modules a system can be built or modified to utilize 4 to 1 200 channels and measurement intervals of 10 ms to 60 s Software developed by Yokogawa an API and a LabVIEW driver are available PC software developed by Yokogawa automatically identifies any connected MX100s A removable terminal unit is available system Configuration MX100 is a data acquisition unit designed to oper
17. ate as a front end for PCs Data measured by MX100 is transferred to PCs in real time Maximum Performance and Ease of Use Connection between a single MX unit and a single PC measurement of 24 channels 10 ms or 60 channels 100 ms One MX unit enables data acquisition on up to 24 channels at a measurement interval of 10 ms or up to 60 channels at a measurement interval of 100 ms six modules installed in both cases a ee ho ee et ee ee os Measured data lt Setting up the System gt The MX and PC are connected via a hub and a straight Ethernet cable Alternatively they can be connected Straight cable i 5 100Base TX Se using a cross cable alone without See Using the hub 4s 4 lt PC Software gt In a one to one connection the Input signal Output signal MX100 standard software included with the main module facilitates easy DC voltage Digital output building of data acquisition DE D environments Digital input EF Mixed input One MX unit consists of a combination of a main module input output modules and a possible base plate This configuration centers on the main module For details refer to pages 4 and 5 Connection between multiple MX units and a single PC for measurement of up to 1 200 channels and the use of MXLOGGER Example of a system with multiple MX units Straight cable poper pET 100Base TX lt Setting up the System gt The MX units and the PC a
18. data writing operations e Base Plate MX150 Number of main modules that can be equipped 1 always equipped Number of I O modules that can be equipped 1 6 to be specified according to the suffix codes e Four Channel High Speed Universal Input Module MX110 UNV H04 Types of measurement a or thermocouple RTD DI non voltage contact level 5 ogic Number of measurement points 4 A D to be equipped independently for each channel Input method Floating unbalanced input insulation between channels A D resolution 20000 6000 16 bit A D is used Measurement interval 10 50 100 200 500 ms 1 2 5 10 20 30 60 s A D integral time 1 67 16 67 20 36 67 100 200 ms AUTO A D integral time is determined by measurement intervals Measurement Ranges and Accuracies Rated Measurement accuracy Measurement accuracy Maximum Input Type resolution measurement range integral time 16 67 ms or more integral time 1 67 ms 1 digit 20 mV to 20 mV 0 05 of rdg 5 digits 0 1 of rdg 25 digits 60 mV to 60 mV P fo afi 200my _ 200mV otami et Ge digite 2Vto 2V_ _ 0 05 of rdg 5 digits 6 V to 6V 20 V to 20V_ 0 05 of rdg 2 digits So 100 V to 100 V However R S 00017600C 0 to 1760 0 0010 1760 0 0 0 to 100 C 3 7 C Ae to ne ic 400 to 600 C 2 0 0 to 1820 0 C Less than 400 C accuracy is not guaranteed 0 05 of rdg 0 7 C ad 200 0 to 1370 0 C Howe
19. e Allows mixed voltage 10 V and current 4 20 mA output Pulse width modulation output module PWM Output Module Removable Terminal e Output of set and calculated values and retransmission of measured values e Use of external power supplies is not necessary with only voltage output An external power supply 24 V is required for current output MX120 VAO M08 www yokogawa com tm and subscribe to Newswave our free e mail newsletter e Output of set and calculated values and retransmission of measured values e Requires external power supply 4 28 V e Outputs pulse widths Pulse intervals can be set from 1 ms to 300 s on each channel Pulse width MX120 PWM M08 Pulse interval Depends on external power supply voltage The 772065 removable terminal is used with the MX120 VAO M08 and MX120 PWM MO08 Keep this leaflet with the MX100 Catalog Bulletin 04M08B01 00E LF 04M08L01 00E MNew Module Specifications A D resolution 20000 6000 16 bit A D is used e Four Channel Medium Speed Strain Module MX112 xxx M04 A D integral time 1 67 16 67 20 36 67 100 200 ms AUTO power supply frequency is automatically Types of measurement Strain gauge or strain gauge sensor static strain detected and is set to 16 67 20 ms A D integral time is determined by measurement Number of measurement points 4 scanning of 4 channels with one A D intervals Input met
20. e function can be set for each channel Time constant measurement interval x N where N is any number of the following 5 10 20 25 40 50 and 100 Input computation function computation function that can be executed in the main module Computation of differences between channels differential computation between arbitrary channels DCV TC RTD DI scaling Measurement interval Filter function Linear scaling computation Possible range for scaling Possible scope for scaling 30 000 to 30 000 Position of the decimal point any digit Alarm alarm function can be executed in the main module This function is enabled even during a communication failure Upper limit lower limit differential upper limit and differential lower limit Number of settings two items per channel Possible range for alarm setting DCV TC RTD DI scaling Hysteresis Alarm ON OFF values are set arbitrarily Number of alarm output points 10 60 points according to the number of mounted DO modules Output mode Excitation non excitation OR Hold non Hold command output Saving the data Save function DCV TC RTD DI Alarm types Backup in the event of a communication failure during data acquisitions by the PC CF Card up to 2 Gbytes Type I Il x one slot When the timeout value 60 s is exceeded if communication is interrupted during the PC s data acquisitions Monitor ON channel Data is saved au
21. easured data in real time It enables waveform displays and digital displays Digital output signals can be generated manually from these buttons Integration Monitor Software provides menu bars in all windows The user can make transitions to other menu windows from any menu window e Detailed Display Setting This menu is used to set data display states such as waveform colors in the monitor window ses amr ro st mam mO mO m pa mni E ra mhi i ao om O 3 Fim re os ot ia a0 wm H ma F so we gE a0 mm a Pa mp ars m af amO m a a oe a m sam m B mn Ri 2 o p ma a waz Fin i Str om T wma a a mi H Lm iman af oa so i F m Aim mae mwa o a _ i Fei ma arms mm oo m am mi F ma ar a af oo E ne p e Hm mea amw m ma i W lt lt om i E Elo ow ae apm ot ciii we i O i B a Fim Wia ii w O jhe wm my of a f a D Lime mha eT C wa oo a _ Er mme i h a ps sa ow tea a mm O j ma F cm wmm PE wi m O wa a Q tee a wur w 0 ima CE a a a a a a E a a 5 a r e Channel Setting This menu is used to enter individual settings such as range settings for each input channel or to set computation channels such as the input of computing equations me wis ish ee an ri e iin _ ao fies E u LP dea tE l Bij E i jinna E i z j z ll o a irm ig go a i oom A
22. eed sores measurement Tons Foes meson speed shone measireren irten Tn 1 NC can be specified only when M10 is specified Measurement interval number of channels M10 Option NC Suffix Option Code Code MX115 Input type DO5 Measurement interval H10 number of channels Description __ Digital input module for MX Non voltage contact level 5 V logic open collector a 10 channels high speed shortest measurement interval 10 ms Option The plate with clamp terminals is not attached Model Suffix Code Description MX125 a Digital output module for MX Output type A contact SPST Output interval M10 10 channels highest output interval 100 ms number of channels Model Suffix Code MX150 a Base plate for MX For connection with one main module and one input output module For connection with one main module and two input output modules 6 For connection with one main module and six input output modules _ Accessories Model __Desoipton _ 772061 Ten Channel Screw Terminal Block Note The 772061 model is applicable only to MX110 UNV M10 Ten Channel Medium Speed Universal Input Module or MX115 D05 H10 Ten Channel High Speed DI Module Description Base type Model Suffix Code 772062 Po Cable for connection between the input module and the screw terminal block 50 cm cable 100 cm cable Note The 772062 model is applicable only betwe
23. els in one group 50 groups multi interval supported graph and digital display print etc Monitor Server main functions retention of 1 800 point data channels connection with DAQLOGGER possible etc Operating environment CPU Intel Pentium III 800 MHz or more recommended Pentium 4 and 1 6 GHz or more Memory 512 MB or more recommended 1 GB or more OS Windows NT 4 0 2000 XP recommended Hard disk capacity Free space of 100 MB or more recommended Hard disk with free space of 2 GB or more that operates at maximum speed Communication interface Ethernet that can be used for Windows recommended 100 Base TX supported CD ROM drive CD ROM drive that can be used for Windows Printer printer that can be used for Windows to be used for printing e API for MX100 DARWIN optional a suite of functions for creating PC software Supported models MX100 DARWIN series Supported OS Widows 98 NT 4 0 SP3 or later 2000 XP recommended Communication system TCP IP Ethernet User development environment MS Visual Studio 6 0 SP5 or later recommended Supported language Visual C Visual C Visual Basic 11 Model Name MX100 P Mainmodule _ S iMlanguage E Power supply voltage Power supply inlet D 3 pin power intel with UL CSA cable power supply cord R____ 8 pin power intel with SAA cable Q___ 8 pin power intel with BS cable vxo __ Analog input module for MX monwes LUNV DoviTcibuRTD channels tigh p
24. en MX110 UNV M10 Ten Channel Medium Speed Universal Input Module and the Screw Terminal Block 772061 or between MX115 D05 H10 Ten Channel High Speed DI Module and the Screw Terminal Block 772061 Cable length Description 772063 Plate with clamp terminals Note The 772063 model is applicable only to MX110 UNV M10 Ten Channel Medium Speed Universal Input Module or MX115 D05 H10 Ten Channel High Speed DI Module Description 772064 Clamp terminals Note The 772064 model is applicable only to MX110 UNV H04 Four Channel High Speed Universal Input Module Description 772065 Clamp terminals Note The 772065 model is applicable only to MX125 MKC M10 Ten Channel DO Module Description Connector cover for base plate Name Model Part No Specifications 250 2 0 1 100 Q 0 1 102 0 1 772066 Shunt Resistance for clamp terminals Shunt Resistance for screw terminals CompactFlash Memory Card CF card only CompactFlash Memory Card CF card only CompactFlash Memory Card CF card only CompactFlash Memory Card CF card only CompactFlash Memory Card CF card only B9968NN YOKOGAWA YOKOGAWA ELECTRIC CORPORATION Adapter for CompactFlash Memory Card Network Solutions Sales Business Div Phone 81 55 243 0309 Fax 81 55 243 0397 E mail tm csv yokogawa co jp YOKOGAWA CORPORATION OF AMERICA YOKOGAWA EUROPE B V YOKOGAWA ENGINEERING ASIA PTE LTD Application Sof
25. ethod conversion other gauge 50 60 Hz is not rejected when the integral time is 1 67 ms methods use conversion by scaling The accuracy applies to standard operating conditions ee Note Commn mode voltage 600 VACrms 50 60HZ reinforced double insulation Note ambient temperature 23 2 C ambient humidity 55 10 RH supply voltage 90 to 250 VAC power frequency 50 Common mode rejection ratio CMRR 60Hz 1 warm up time 30 minutes or more without adverse conditions such as vibrations 120 dB or more when the integral time is 16 67 ms or more 80 dB or more when the integral time is 1 67 ms Measurement Measuring range Integral time 16 67 ms or more Integral time 1 67ms 50 60 Hz 0 1 500 Q imbalance for voltage between the minus measurement terminal and a ee 0 2000 ustrain 2000 0 strain 0 5 of range 2 of range Common mode voltage between channels 120 VACrms 50 60 Hz for DCV DI 20000 ustrain 20000 ustrain 0 3 of range 1 of range Oo E l _ 50 VACrms 50 60 Hz for RTD resistance 200000 ustrain 200000 ustrain 0 3 of range 1 of range Noise rejection Rejection by the integrating A D and the use of low pass filters Input resistance 10 MQ or more at the 1 VDC range or lower Approximately 1 MQ at the 2 VDC range Input resistance 1 MQ or more or higher Allowable wiring resistance 100 or less Insulation resistance 20 MQ or more between an input terminal and ground 500 VDC Allowable input voltage 10 V
26. ge resistance built in bridge resistance of 120 Q of 350 772067 MX112 B12 M04 MX112 B35 M04 MX112 NDI M04 A ragas mee atenat doe ead ane strain gauge type sensor MX110 V4R M06 MX115 D24 H10 MX112 B12 M04 and MX112 B35 M04 allow gauge connection methods to be independently selectable on each channel through DIP switch settings Voltage ranges Perfect for cost e The 772063 removable plate with clamp 20 mV to 100 V effective measurement terminals can be used with the MX115 RTD ranges of multipoint 24 V logic D24 H10 Pt50 Pt100 JPt100 signals Pt500 Pt1000 Cu10 and others Resistance ranges 20 Q 200 Q 2 KQ Of the new modules introduced in this leaflet only the MX115 D24 H10 can use the 772061 M4 screw type terminal block 772062 connection cable Digital inputs Of the new modules introduced in this Non voltage contacts leaflet only the MX115 D24 H10 5 V logic supports the NC option NC The plate with clamp terminals is not attached When using strain gauge type sensors without remote sense wires with the MX112 NDI M04 use a DV450 001 strain conversion cable DARWIN accessory sold separately e The model 319300 external bridge head 120Q sold separately is available for the MX112 NDI M04 e Output Module Name Model Number of Output update part channels itera Description Analog Output Module MX120 VAO M08 8 100 ms PWM Output Module MX120 PWM M08 8 100 ms Analog Output Modul
27. ground Common mode voltage between channels 250 VACrms 50 60 Hz double insulation Noise rejection Rejection by the integrating A D converter and the use of low pass filters 10 MQ or more for the DC voltage of 200 mV range or less and also for the thermocouple range Approximately 1 MQ if the DC voltage is 2 V range or more Approximately 1 MQ while measurement is stopped 20 MQ or more between the input and the ground 500 VDC 10 nA or less except for the burn out setting 2300 VAC 50 60 Hz between input terminals one minute 3700 VAC 50 60 Hz between an input terminal and the ground one minute 2 kQ or less for DC voltage and thermocouple 10 Q or less per cable for RTD 50 Q or 100 Q systems 1 Q or less per cable for RTD 10 Q or 25 Q systems Superposed electric current system detection within the thermocouple range ON OFF possible 0 01 uF or less Approximately 3 W Approximately 57 x 131 x 150 mm including the terminal cover Approximately 0 5 kg in terminal Applicable cable size is 0 2 2 5 mm AWG24 Input resistance Insulation resistance Input bias current Withstand voltage Input signal source resistance Thermocouple burn out Parallel capacity during RTD Power consumption External dimension Weight Terminal type e Ten Channel Medium Speed Universal Input Module MX110 UNV M10 Types of measurement re E thermocouple RTD non voltage contact level 5 V ogic
28. hod Floating balanced input Measurement interval 100 200 500 ms 1 2 5 10 20 30 60 s A D resolution 20000 16 bit A D is used except for an integral time of 1 67ms Special input ranges that can be used for MXLOGGER or API Same as DCV and RTD ranges of A D integral time 1 67 16 67 20 36 67 100 200 ms AUTO power supply frequency is automatically MX110 UNV M10 detected and is set to 16 67 20 ms A D integral time is determined by measurement Maximum input voltage 1 VDC range or less RTD resistance DI contact 10 VDC continuous intervals Other measurement ranges 120 VDC continuous Measurement interval 100 200 500 ms 1 2 5 10 20 30 60 s Normal mode voltage Gauge connection method Single gauge 2 or 3 wire opposed side two gauge adjacent side two gauge VDC DI LEVEL 1 2 times the rated range or less 50 60 Hz peak values including signals or four gauge 2 KQ resistance RTD 100 500 1000 Q systems 50 mV peak Applicable gauge resistance 100 to 1000 Q Built in resistance of 120 Q for B12 and 350 Q for B35 200 Q resistance RTD 10 25 50 Q systems 10 mV peak Bridge voltage 2 VDC fixed accurate to 5 20 Q resistance 4 mV peak Balance adjustment range 10 000 u strain Normal mode rejection ratio NMRR Applicable gauge factor 2 0 fixed gauge factor correction possible with scaling function 40 dB or more 50 60 Hz 0 1 when the integral time is 16 67 ms or more Measurement ranges and accuracies single gauge m
29. l time 1 67 ms 1 digit Oto 60mV 0 05 of rdg 20 digits 0 1 of rdg 100 digits Voltage 1 Vto 1V 0 05 of rdg 2 digits 0 1 of rdg 10 digits 100 uV 0 05 of rdg 20 digits 0 1 of rdg 100 digits 100 uV Supported thermocouple PLATINEL PR40 20 NiNiMo WRe3 25 W WRe26 N AWG14 Supported RTD Cu10 at 20 C a 0 00392 Cu10 at 20 C a 0 00393 Cu25 at 0 C a 0 00425 Cu53 at 0 C a 0 00426035 Cu100 at 0 C a 0 00425 Pt25 Cu10 GE high resolution Cu10 L amp N high resolution Cu10 WEED high resolution and Cu10 BAILEY high resolution Reference junction compensation External internal switchover can be performed for each channel Reference junction compensation accuracy During the measurement of 0 C or more and during the input terminal temperature balance Type R S W 1 C Type K J E T N L U 0 5 C Note Internal reference junction compensation for Type B is fixed to 0 C Maximum input voltage 200 mV DC range or less thermocouple RTD DI CONT 10 V DC Other measurement ranges 120 VDC Normal mode voltage DCV TC DI level 1 2 times of the rated range or less 50 60 Hz peak values including signals RTD 100 Q system 50 mV peak RTD 10 25 50 Q systems 10 mV peak Normal mode rejection ratio NMRR 40 dB or more when the integral time is 16 67 ms or more 50 60 Hz 0 1 50 60 Hz is not rejected when the integral time is 1
30. ll be compatible with your configuration For Current Owners of DAQMASTER Series Instruments Use of the new input output modules and options introduced in this leaflet requires upgrading of your main module and PC software An upgrade kit for the main module is available model 772050 01 For more details please contact your nearest Yokogawa representative YOKOGAWA YOKOGAWA ELECTRIC CORPORATION Subject to change without notice Network Solutions Business Div Phone 81 422 52 7179 Fax 81 422 52 6793 Ed 01 0 Copyright 2004 E mail tm csv yokogawa co jp Printed in Japan 409 KP YOKOGAWA CORPORATION OF AMERICA Phone 1 770 253 7000 Fax 1 770 251 2088 YOKOGAWA EUROPE B V Phone 31 33 4641 806 Fax 31 33 4641807 YOKOGAWA ENGINEERING ASIA PTE LTD Phone 65 62419933 Fax 65 62412606 RS 14E
31. n software main function calibration function Operating environment CPU Intel Pentium II 400 MHz or more recommended Pentium III and 1 GHz or more Memory 256 MB or more recommended 512 MB or more OS Windows NT 4 0 2000 XP recommended Hard disk capacity Free space of 50 MB or more recommended Hard disk with free space of 1 GB or more that operates at maximum speed Communication interface Ethernet that can be used for Windows recommended 100 Base TX supported CD ROM drive CD ROM drive that can be used for Windows Printer printer that can be used for Windows to be used for printing e MXLOGGER optional This is used to connect multiple MX units Up to 20 units can be connected Setting Logger main functions Setting of the basic connection setting of various conditions range alarm interval computation project functions logging computation function 60 channels computation across units possible alarm output file split function save manual DO activation of various types of software etc Monitor main functions Display related settings 32 channels in one group 50 groups monitor displays trend digital meter alarm multi interval supported temporary suspension tag tag comment channel display switchover marking function etc Viewer main functions Re display of saved data files data synchronization processing file merge display limited to files that can be merged 32 chann
32. nd output manual output details is as same as MX120 VAO MO08 Output update cycle 100 ms Duty resolution 1 ms interval setting range 1 12000 10 ms interval setting range 1 60000 Output format External power supply sourcing ON resistance 2 or less when the output current is 200 mA or more External power supply 4 V to 28 V Output capacity Max 1 A ch however the total of one module is 4 A or less Insulation resistance Between an output terminal and ground 20 MQ or more 500 VDC Between output terminals non isolated 200 0 to 550 0 C Cu10 GE 200 0 to 300 0 C e 0 1 C 0 1 C 0 1 C Cu10 WEED 200 0 to 300 0 C Cu10 BAILEY 200 0 to 300 0 C f J263B 0 0 to 300 0 K 0 05 of rdg 0 3 K Withstanding voltage Between an output terminal and ground 2300 VACrms 50 60 Hz for one minute Between output terminals non isolated Power consumption Approximately 2 5 W excluding power consumption of external voltage sources measurement i current 1 mA Ni120 70 0 to 200 0 C Cu10 L amp N 200 0 to 300 0 C 0 1 of rdg 2 C 0 2 of rdg 5 C neasa Pt500 200 0 to 600 0 C 0 05 of rdg 0 3 C 0 1 of rdg 1 5 C 0 1 C current 0 25 mA 2 Pt1000 200 0 to 600 0 C 0 000 to 20 000 Q 0 05 of rdg 7 digits 0 1 of rdg 25 digits 10 001 Q wire euer Enma 0 00 to 200 00 0 40 05 frag Seats 0 1 of a6 150s 0 01 2 resistance L_lmessuemenrcurent imay_ 0 00 to 200 00
33. nections with Yokogawa s data logging software DAQLOGGER It is effective when combining MX units with Yokogawa s data acquisition equipment such as DARWIN and DAQSTATION DAQLOGGER is scheduled to be capable of supporting MXLOGGER s monitor server function in July 2003 i d E gt j 1 al HEK Example of building a mixed system of MX100 and DARWIN DAQLOGGER becomes a client of MXLOGGER to simultaneously retrieve data from MXLOGGER and from DARWIN Note The shortest data acquisition interval of DAQLOGGER is one second If it is necessary to save data with a measurement interval of less than one second data needs to be saved by MKLOGGER DAQ a DAQLOGGER and MXLOGGER are provided RX WO as basic software for Yokogawa s data al acquisition PC software DAQWORX DX100 200 API for MX100 DARWIN Optional If users wish to create their own data acquisition software please use this API The API consists of a suite of functions to communicate with MX100 DARWIN The suite of functions contains DLL dynamic link library API makes it possible to create data acquisition software dedicated to the MX or data acquisition software combining the MX and DARWIN or data acquisition software dedicated to DARWIN Three languages Visual C Visual C and Visual Basic are supported 10 Hardware Specifications Common Specifications e Normal operating conditions Operating temperature range
34. om 5 to 100 measurement interval times Therefore filtering can be applied according to the noise to be rejected lt Example of Noise Rejection gt When the noise source in the left figure was applied to the MX the result in the right figure was obtained High speed measurement can be stably performed even in noise environments e Output window of MX100 for noise inputs Module used MX110 UNV H04 Four Channel High Speed Universal Input Module Measurement with the range of 2 V 2 V to 2 V measurement interval of 50 ms integral time Auto and filter OFF e Noise source applied to MX The noise signal was applied between H and L in normal mode 10 us Sampling rate 500 MS s Measurement using Yokogawa s Digital Oscilloscope DL1740 Foody The MX Standard Software was used for PC software MX100 Standard Software Standard Software for the Main Module MX100 This software is used to connect a single MX unit for performing data acquisition it is not possible to connect multiple MX units It includes three software elements integration monitor viewer and calibration lt Integration Monitor Software gt This software performs real time monitoring and logging of measured data It consists of six menus Monitor Window Detailed Display Setting Channel Setting Acquisition Condition System Setting and Connection disconnection C ___ e Monitor Window This window is used to monitor m
35. oximately 0 5 kg Terminal type Clamp terminal Applicable cable size 0 14 1 5 mm AWG26 16 e Ten Channel High Speed Digital Input Module MX115 D05 H10 Input type Non voltage contact open collector level 5 V logic Number of measuring points 10 Terminal type Clamp terminal Applicable cable size 0 14 1 5 mm AWG26 16 Input format Pull up at approximately 5 V approximately 5 kQ No insulation between channels Measurement interval to be selected from 10 50 100 200 500 ms or 1 2 5 10 20 30 60 s Minimum detection pulse width two times or more of a measurement interval Input threshold level Non voltage contact open collector On for 100 Q or less Off for 100 kQ or more Level 5 V logic Off for 1 V or less On for 3 V or more Hysteresis width Approximately 0 1 V Rated contact for connection to input terminals rated transistor Rated contact with 15 VDC or more and 30 mA or more Rated transistor with Vce gt 15 Vdc and Ic gt 30 mA Insulation resistance 20 MQ or more 500 VDC between an input terminal and the ground Withstand voltage 2300 VAC between an input terminal and the ground one minute Power consumption Approximately 1 5 W External dimension Approximately 57 x 131 x 150 mm including the terminal cover Weight Approximately 0 5 kg e Ten Channel Medium Speed Digital Output Module MX125 MKC M10 Number of output points 10 Terminal type
36. re connected by means of a hub and straight Ethernet cables lt PC Software gt Acquisition of data from multiple MX units is well supported by Yokogawa s software MXLOGGER optional MXKLOGGER enables data acquisitions of up to 20 MX units one unit has inputs of up to 60 channels or 1 200 channels on 20 units Please note that the shortest measurement interval of MXLOGGER depends on the system s total number of channels and the PC s performance For guidelines on measurement intervals and the number of channels please refer to page 6 If users wish to create their own data acquisition software there is no limit to the number of MX units that can be integrated with a single PC software element Please note however that if conditions with heavy loads such as short measurement intervals with many units are set to the PC and its software data will not be acquired in time and some data may be lost Up to 20 units ae ae S Hi 1 A i Maximum Performance and Ease of Use J The MX is designed to enable desired measurement environments by combining three elements the main module input output modules and a base plate The assembled unit can be utilized on the desktop as is the modules have legs Please note that DIN rails are used for rack mounting Base Plate Input Output Module Main Module Main Module MX100 The main module is the engine that controls data
37. rformance may differ from that shown in the table lt PC System Requirements gt CPU Pentium 4 3 2 GHz Memory 1 GB OS Windows 2000 Hard disk 160 GB Communication interface Ethernet 100Base TX Multi Interval Measurement Three types of measurement intervals can be used in a single system in various combinations Measurement intervals are specified for each module It is also possible to set different types of input modules to the same measurement interval or to set the same type of input modules to different measurement intervals Twelve measurement intervals are available as user selectable options 10 ms 50 ms 100 ms 200 ms 500 ms 1s 2 s 5 s 10s 20s 30s and 60 s Please note however that measurement intervals of 10 50 ms cannot be set to the Medium speed Universal Input Module MX110 UNV M10 lt Examples of Setting Measurement Intervals gt lt Monitor Window Using Yokogawa s Proprietary PC Software gt Multi interval systems can be flexibly built for The window shows measurement values by measurement intervals each module as shown in the figure below Measurement can be performed while confirming rapidly changing signals Three colors are used to indicate the three and slowly changing signals simultaneously types of measurement intervals Example 1 Example 2 Example 3 mr en er Ep Measurement of sine Measurement of waves at 8 Hz witha sine waves at 1 measurement inte
38. rval of Hz witha 10 ms measurement interval of 50 ms Measurement of sine waves at 0 5 Hz witha measurement interval of 100 ms hrady Us G MT rs S01 aE High Withstand Voltage Reinforced Insulation Reinforced double insulation has been provided between the input terminals and the case to achieve a high withstand voltage of 600 Vrms VDC continuous As shown below each battery voltage can be measured even if the batteries are stacked to increase common mode voltages Allowable common mode Measurement object MX system voltage of one MX system EEE Vmax 600 Vrms Vdc continuous Module N Allowable common mode voltage between modules Vmax 600 Vrms Vdc continuous Module 1 N 4 or 10 meee tee E Allowable common mode voltage between channels in a module e Ten Channel Universal Input Module 120 Vrms Vdc continuous e Four Channel Universal Input Module 250 Vrms Vdc continuous Noise Rejection MX110 UNV H04 MX input modules employ integrating A D converters with superior noise rejection performance In particular the MX110 UNV H04 Four Channel High Speed Universal Input Module incorporates an integrating A D converter for each input channel thereby exhibiting strong noise rejection performance in high speed measurement Moreover the digital filtering function is effective on noises that cannot be fully rejected even with integrating A D converters Time constants can be selected fr
39. s 4 pV Maximum allowable output range Voltage 11 to 11 V current 0 to 22 mA iev Load resistance Voltage 5 kQ or more current 600 Q or less Accuracy at rated output 0 2 of F S F S 10 V or 20 mA at standard operating conditions ee 200mv_ 200 00 to 200 00 mV However for current output accuracy is met at 1 mA or more Voltage 2 0000 to 2 0000 V 0 05 of rdg 5 digits 100 uV Output resolution 12 bit of F S or more EEANN 0 1 of rdg 10 digits External power supply used for current output 24 V 10 and current capacity of 250 mA or more C ov gt a Insulation resistance Between an output terminal and ground 20 MQ or more 500 VDC 20A hear digits Between N terminals a minus terminals a A potential Withstanding voltage Between an output terminal and ground 2300 VACrms 50 60 Hz for one minute Threshold level accuracy 0 1 V Between output terminals non isolated minus terminals share common potential 1 kQ or less ON 100 kQ or more OFF parallel capacity is 0 01 u F or less 1 Power consumption Approximately 2 5 W excluding power consumption of external voltage sources abate fore oic Eight Channel Medium Speed PWM Output Module MX120 PWM MO08 Number of output points 8 Pulse output interval 1 ms to 30 s 1 ms interval setting range set in 1 ms units per channel 10 ms to 300 s 10 ms interval setting range set in 10 ms units per channel Output data Comma
40. tem restarts the MX100 will be connected automatically without making network settings ii i t MX being used by other users can be confirmed here The connected MX100 is identified automatically Select the MX to be connected If necessary provide network settings such as IP addresses All of the network settings changes can be performed from the PC software there is no need to access the MX100 itself directly for example hardware switch settings lt Viewer Software gt lt Calibration Software gt This software is intended to re display saved data It enables This software is intended to efficiently carry out the calibration waveform displays digital displays cursor displays interval of universal input modules arithmetic and other functions 4 Measured data can be converted m into various formats such as Excel Lotus or ASCII i Lai pet D eega ced ricer Ps i Pisses inp fe Bheri ite Ich and She s Bo Jom Data saved in multiple measurement intervals are re displayed in each measurement interval using one data file u Results of interval arithmetic MXLOGGER Optional PC Software MXLOGGER is used to connect multiple MX units up to 20 units for data acquisition one MX unit can also be connected It consists of software elements setting logger for saving data monitor and viewer and the monitor server The monitor server function is used to enable con
41. to R2 01 1 Measured data can now be saved to the PC and CF card installed in the MX100 MXLOGGER WX103 End of February 2005 upgrade R1 03 to R2 01 simultaneously This function only available when the system s shortest measurement GateMX100 End of February 2005 upgrade R1 02 to R2 01 interval is 100 ms or more API MX190 Simultaneous upgrade with new input output modules R1 02 to R2 01 2 Data can be saved to CF card without a PC The CF card is installed in the MX100 LabVIEW driver free of charge Available for download from the Yokogawa Web site starting at the end of February 2005 upgrade from REV 0 7 to allowing the MX100 to be used as a standalone logger REV 2 01 3 Automatic retention function restores the operation mode that was active when the In order to provide support for the new input output modules the main module MX100 must be upgraded along with the software from style number power was Cut S1 to S2 Please be aware that revision 1 03 or earlier PC software products cannot be connected to the new main module style S2 However the oo style number of the main module is irrelevant if using the latest version of the software For example PC software of revision 2 01 or later can be This option is included with style number S2 of the main module connected to a style S1 main module without any problems When purchasing PC software products please confirm the versions of the main module and PC software that wi
42. tomatically approximately every 60 s If the PC s data acquisition is recovered or if the CF Switch is pressed Data guarantee during a power failure Guaranteed until data is written immediately before the MX is turned off for example power failure The backup operation will not continue after the system recovers from a power failure Supported external media Save trigger Save channel Save interval Stopping the save function Indication LED 7 segment indication Indication of Ethernet status MX status indication by 7 segments in 2 digits unit no operation status indication indication of error occurrence indication of messages concerning the CF Card etc Communication functions Interface Basic protocol Transmission function Receiving function General specifications Power consumption Insulation resistance 100Base TX 10Base T automatic detection Ethernet TCP IP UDP ARP ICMP Transmission of measured values and setting values Reception of setting values Approximately 8W for the main module only 20 MQ or more 500 VDC between the power supply terminal and the ground terminal 1500 VAC 50 60 Hz between the power supply terminal and the ground terminal one minute Approximately 92 x 131 x 137 mm Withstand voltage External dimension Weight Approximately 0 85 kg Other functions Switch 8 bit dip switch for IP address initialization etc CF switch Switch to stop the
43. tware Model Remarks ____ _ MX180 MX100 Standard Software For connection with one MX unit WX103 MXLOGGER For connection with multiple MX units Up to 20 units i WX101 DAQLOGGER For mixed connection of MX DARWIN MV DX uR MX190 API for MX100 DARWIN Suite of functions for creating programs Exterior Dimensions Number of equipped ipwroupt modes 1 2 3 4 5 6 Clo DeL JIU Op 772061 Mounting dimensions in upward downward directions TCP IP software of this product and documents on TCP IP software were developed created by Yokogawa Electric Corporation on the basis of BSD Networking Software Re lease 1 licensed from University of California Microsoft MS Windows and Excel are registered trademarks of Microsoft Corporation in the United States Lotus and 1 2 3 are registered trademarks of Lotus Development Corporation MMX and Pentium are registered trademarks of Intel Corporation in the United States Ethernet is a registered trademark of XEROX Corporation LabVIEW is a trademark of National Instruments Corporation All other company and product names mentioned here are trademarks or registered trade marks of their respective companies
44. u a Ii D Oo Dimi E a i D z o E s mimmi E u ima a i Bo k oO k E i m E arag oa a i E 3 z Sia E aP ed a i E O 7 Eis E n aL 4 iG z a z z e E i im m a ig G g Ela ME pimi Ew o r P Bimm 2 ar i i ka O z 6 5 F fia ea m nm Lom Fi o piau A f r oe tom CO r H r e ia A P pE hi 5 m z Bims E a a i Ln 6 E J E E Ei ti i Pi hi r T r z Sia E ar D a La O z m r 2j Bims Bm Eir LHE em O o E Dimmi E r jp Loa O u oO z a Siem A at pam fm O z j r Sian E p Eo u ry Si om a ar il i Lae n i E a af CRE hi a z a a TEO i E T H bh M J ae ALT thd e Acquisition Condition This menu is used to set various conditions Such as measurement intervals data save intervals measurement start end conditions or file name designation for data acquisitions Drag and drop the symbol of the input module Then allocate it to the measurement interval group eee ed Le ey ye O os ee ma i ass ia iew pas ane a pag Ee sa ieee i tied Leelee takii ia SS l G Bee e System Setting This menu is used to decide module configurations etc Module configurations are shown in easily understood diagrams e Connection Disconnection Easy to Set Up The connected MX100 is identified automatically Once connection setting information is provided it will be retained When the sys
45. ver 200 to 100 C RJC accuracy 0 05 of rdg 1 C _ Measurement not possible 0 1 C not included 200 0 to 800 0 C ee ee S jo o ele 2 e Voltage 0 1 of rdg 10 digits 3 lt 3 lt gt 3 lt 0 05 of rdg 1 C Burn out setting ys 200 0 to 1100 0 C 0 05 of rdg 0 5 C 5 A T However J L T 200 0 to 400 0 C 200 to 100 C 0 05 L 200 0 to 900 0 C U 200 0 to 400 0 C is OFF of rdg 0 7 C FUN 0 0 to 1300 0 C 10 05 of io iO TO 0 1 of rdg 0 7 C Measurement not possible 0 1 C ee ee RTD 0 05 of rdg 0 3 C 0 01 C TR 0 05 of rdg 0 3 C Measurement not possible 0 1 C dale ineasienent i a Cee a l Threshold level accuracy 0 1 V Contact 100 Q or less ON 10 kQ or more OFF Special Inout Ranges that can be used in MKLOGGER Rated measurement Measurement accuracy Measurement accuracy Maximum Input Type resolution range integral time 16 67 ms or more integral time 1 67 ms 1 digit 0 1 of rdg 100 digits 1 Vto 1V 0 05 of rdg 2 digits 0 1 of rdg 10 digits 100 uV Oto 6V 0 05 of rdg 20 digits 0 1 of rdg 100 digits 100 uV PLATINEL PR40 20 NiNiMo WRe3 25 W WRe26 N AWG14 PT100 high noise resistance JPt high noise resistance Cu10 at 20 C a 0 00392 Cu10 at 20 C a 0 00393 Cu25 at 0 C a 0 00425 Cu53 at 0 C a 0 0042603

Download Pdf Manuals

image

Related Search

Related Contents

NEC Express5800/120Rg-2 User's Guide  GPA777 Introduction au génie logiciel  Vanguard Heating VN1800ITB User's Manual  

Copyright © All rights reserved.
Failed to retrieve file