Home

Mv1b1 User Manual

image

Contents

1. apstracker net w Freedom is lost now Mvl1bl1 User Manual Thank you for purchasing the tracker This manual shows how to operate the device smoothly and correctly Make sure to read this manual carefully before using this product Please note that specification and information are subject to changes without prior notice in this manual Any change will be integrated in the latest release 1 Summary functions Working Based on existing GSM GPRS network and GPS satellites this product can locate and monitor any remote targets by SMS or GPRS 1 Main functions e GSM quad band frequency for globe use e Real time tracking location by SMS GPRS e Real time voice monitoring function e Recover original password e Set authorized number e Reboot device e Overspeed alarm alarm e ACC anti theft alarm ORD ingolabs apstracker net w Freedom is lost now 3 Specs ee O GPS accuracy 5m Cold status 45s Time To First Fix Warm status 35s Hot status Is 5 95 4 Installation instructions 4 1 Preparation 4 1 1 Open the package to check the device model number is correct be with full accessories or else please contact your supplier 4 1 2 Choose SIM card need insert a GSM SIM card into the device please refer to the suggestion of your supplier for SIM card choice Notice Please turn the device power switch to on before install SIM card The SIM card need open the GPRS function Please
2. Freedom is lost now information about the local APN inquiry from your local GPRS network operator 6 12 1 2 Send SMS apn password APN content APN user name APN password via a cell phone and if succeeded the tracker will return the message set APN OR E g send SMS command apn 123456 airtelgprs Notes airtelgprs 1s the APN content of airtel Mobile it has no APN user name and password If there is no APN user name and password then no need to write APN user name and password 6 13 IP and Port setting 6 13 1 Send SMS IP password ip address port number If succeeded set ip address and port ok will be returned by SMS Note IP in SMS must be capital letter E g Send SMS command IP password 37 59 232 31 10202 to the device 37 59 232 31 is IP 10202 is port 6 16 Power failure alarm optional Built in backup battery to realize power failure alarm it will send SMS cut power alert to the authorized number 6 17 Check device setting parameters Send SMS TCP to device device will reply SMS P porttAPN GPRS setting A valid V invalid 6 18 Web platform GPS tracking software Web based platform www gpstracker net in Further details please contact manufacturer Note 1 to know additional features of server plz click on this link http www gpstracker net in premiumserversupport html 2 for quicksetup manual download from below link http gpstracker net
3. CC wire 6 Device Parameter Settings 6 1 Initialization Send SMS begin to the tracker it will reply begin ok and initialize all the settings Default password 123456 Remark initialization is resetting all the parameters to factory defaults For example send SMS begin If succeeded it will reply begin ok OED inqgoiabs apstracker net w Freedom is lost now 6 2 Set password 6 2 1 Set Password Send SMS password old password new password to the unit to change the password For Example send SMS password 123456 666888 to device it will reply SMS password OR 6 2 2 Make sure the new password is in 6 digits arabic numbers or the device cannot recognize the password 6 2 3 Resume original password send SMS resume to the device it will reply SMS resume password password 1s 123456 6 3 Authorization 6 3 1 Set authorization send SMS admin password cell phone number to set up authorized number device will reply admin ok 6 3 3 Delete authorization send SMS noadmin password authorized number to delete the authorized number device will reply no admin ok 6 4 Single Locating 6 4 1 If there is no authorized number any number dials up the device number it will report tracking message If already set authorized number then it will not respond when an unauthorized number calls it 6 4 2 Dialing tracking make a c
4. all to device number it will hang up and reply a real time tracking message 6 4 3 SMS tracking send SMS smslink 123456 it will reply a real time tracking message Tracking location when GPS signals is weak you will receive the last location when GPS is available If it is different with its exact current location pay attention to check the time included in the SMS 6 5 Get geographical location 6 5 1 Must set the SIM Card APN parameter firstly before using this function if there is APN user name and password Please refer to point 6 13 to set 6 5 2 Send SMS DW to device it will reply current location info For example 13 100 meerpet Hyderabad Note this function may not work in some certain area OED ingolabs apstracker net w Freedom is lost now 6 6 Auto continuous track 6 6 1 Limited times auto track Send SMS at 30 sum 15 to the device it will reply the 66 99 S tracking message at 30s intervals for 15 times default s second 6 6 2 Unlimited time auto track Send SMS at 30 sum 0 to the device Remark device must be connected to tracking software 6 6 3 Cancellation Send SMS noat password to the device 6 7 Voice Surveillance 6 7 1 The command to switch between Track and Monitor are tracker and monitor 6 7 2 The default mode is track Tracking status 6 7 3 Send SMS monitor password to the device and it will reply monitor
5. in download mvib1 pdf 3 download android gps settings application http gpstracker net in download Gps 20Settings apk 4 Download desktop application from http www gpstracker net in download pwebtrack rar 5 for other network sim card apn names http www gpstracker net in download apnnames pdf 6 this device carries 2year warranty from the date of server registration If you have any more queries regarding installation please can call us on 09700025002 or 040 64559002 or mail us at contactus gpstracker net in website http www gpstracker net in Office Address ingo labs 13 100 meerpet Hyderabad 500097 OED ingolabs
6. make sure SIM card with full balance 4 2 Installation The device is hidden type installation we suggest the device installing by professional institution Please pay attention to the following points 4 2 1 To avoid the thieves destruction the device installation place should be as far as hidden 4 2 2 Avoid putting the device with reversing radar car burglar alarm and any other vehicle communication devices COPD ingolabs apstracker net w Freedom is lost now 4 2 3 Can fix the device by ribbon or wide sponge powerful two side glue stick 4 2 4 The device has built in GSM and GPS antenna make sure the receive side upward and there is no metal shielding 4 2 5 Recommended installation place Jhe hidden place in the board below the front windscreen 2 The hidden place around former dashboard nonmetal material for skin The hidden place in the board below the back windscreen wiring diagram mvibimodel e BE i green ignition ve dummy wire Ye ov mv ibiunit Notice If the windscreen glued by metal thermal insulation layer or heating layer it will reduce the GPS receive signal and lead to GPS work disorder then please change the installation place 5 Wires connection 1 Red wire connects to vehicle power anode 2 Black wire connects to vehicle power cathode 3 Yellow wire connects to oil or circuit control wires 4 Green wire connects to ACC wire Note Device must connect to A
7. ok and switch to monitor mode Then use mobile phone to dial the device number it will get though and enter voice listening function 6 7 4 Send SMS tracker password to the device it will reply tracker ok and restore to track mode 6 9 Overspeed alarm 6 9 1 Set up Send SMS speed password speed number in 3 digits to the device suppose the speed is 80km h EG send SMS speed 123456 080 and it will reply speed ok When the car moves exceeding 80 km h the unit will send SMS alert speed alarm to the authorized number 6 9 2 Cancel send SMS nospeed password to deactivate the overspeed alarm it will reply cancel speed ok 6 10 ACC ON alarm 6 10 1 Send SMS ACC ON to device to start illegal start alarm function when vehicle ignition on device will reply ACC to the authorized number 6 10 2 Send SMS ACC OFF to device to close the function 6 11 Time Zone Setting Remark UTC 5 30 is default time zone 6 11 1 Send SMS timezone password direction time zone value in hours time zone in munites If set OK it will reply time zone ok If in UTC 5 30 send SMS timezone 1 23456 E 5S 30F 6 12 GPRS setting User must send SMS via cell phone to set IP port and APN before starting GPRS 6 12 1 Setting APN 6 12 1 1 APN standards for Access Point Name and differs from country to country For more OED ingolabs pstracker wet Lw