1. 1 The pipes should be placed along the wall bent reasonably and hidden possibly Min semidiameter of bending the pipe is 10cm HNN l ja cree Mi sa I 2 If the outdoor unit is higher than the wall wa hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room Note e The through wal height of drain hose Slant the drain hose slightly dow shouldn t be higher than the outlet nwards The drain hose can t be pipe hole of indoor unit curved raised and fluctuant etc the drain h py ee upwards xX The drain hose can t be fluctuant in water in order to drain smoothly eon x e The water outlet can t be placed The drain hose can t be fluctuant Tmhe water fh outlet can t be fluctuant The water outlet can t be placed iS in water 25 Vacuum pumpin Use vacuum pump 1 Remove the valve caps on the liquid valve and gas liquid valve valve and the nut of refri gerant charging vent 2 Connect the charging hose refrigerant of piezometer to the refri a k gerant charging vent of gas nut of refrigerant valve and then connect the charging vent other charging hose to the vacuum pump 3 Open the piezometer com pletely and operate for 10 15min to check if the pressure of piezometer re mains in 0 1MPa 4 Close the vacuum pump and maintain this
2. a 4 Put wiring cover back and then tighten the screw 5 Close the panel Note e All wires of indoor unit and outdoor unit should be connected by a professional e f the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself e For the air conditioner with plug the plug should be reachable after finishing installation e For the air conditioner without plug an circuit break must be installed in the line The circuit break should be all pole parting and the contact parting distance should be more than 3mm 21 Installation of indoor unit Step eight bind up pipe 1 Bind up the connection pipe power connection pipe drain hose and cord and drain hose with the band I indoor and indoor 4 outdoor power cord i I indoor power cord 3 Bind them evenly 4 The liquid pipe and gas pipe should l be bound separately at the end 2 Reserve a certain length of drain hose and power cord for installation i Note when binding them When binding to e The power cord and control wire a certain degree separate the indoor can t be crossed or winding power and then separate the drain f The drain hose should be bound hose l at the bottom Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the ga
3. i MUAH AHL PT At least 50cm HHT LALALE Space to the et ae Kp 3 obstruction a 7 Drainage pipe 15 Tools for installation 1 Level meter 4 Drill head 5 Pipe expander 7 Open end wrench 8 Pipe cutter 11 Pressure meter 13 Inner hexagon spanner 10 Vacuum pump 3 Impact drill 6 Torque wrench 9 Leakage detector 12 Universal meter 14 Measuring tape e Please contact the local agent for installation e Don t use unqualified power cord Selection of installation location Basic requirement Installing the unit in the following pla ces maycause malfunction If it is un avoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas 3 or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances surroundings of a laundry a bath a shower or a swimming pool Outdoor unit 1 2 Indoor unit There should be no obstruction near air inlet and air outlet Select a location where the condensat ion water can be dispersed easily and wo
4. please replace them e Check whether remote cont roller appears to be damaged If yes replace it e Take the remote controller close to indoor unit e Turn off the fluoresent lamp and then try it again e Eliminate obstacles e After reaching to set temper ature indoor unit will stop bl owing out air e Heating mode is turned on just e In order to prevent blowing now 11 out cold air indoor unit will be started after delaying for sev eral minutes which is a nor mal phenomenon Malfunction analysis Phenomenon Air condit ioner can t operate Mist is em itted from indoor unit s air outlet Set temper ature can t be adjusted Cooling heating effect is not good Check items e Power failure e Is plug loose e Circuit break trips off or fuse is burnt out e Wiring has malfunction e Unit has restarted immediately after stopping operation e Whether the function setting for remote controller is correct e Indoor temperature and hum idity is high e Unit is operating under auto mode e Your required temperature exceeds the set temperature range e Voltage is too low e Filter is dirty e Set temperature is in proper range e Door and window are open 12 Solution e Wait until power recovery e Reinsert the plug e Ask professional to replace circuit break or fuse e Ask professional to replace it e Wait for 3min and then turn
5. is different according to the diameter please refer to the sheet below l l l l l l l l l l l l l B Remove the burrs I e Remove the burrs with shaper and l prevent the burrs from getting into l the pipe i l l l l l l l l l l l l l l downwards F Inspection e Check the quality of expanding port If there is any blemish expand the port again according to the steps above C Put on suitable insulating pipe D Put on the union nut e Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe smooth surface TP improper expanding il Yer Vr leaning damaged crack uneven surface thickness the length is equal 30 5610 NW 12 Ave Suite 209 211 Fort Lauderdale FL 33309 Ph 954 771 1415 Fx 954 771 1418 INTERNATIONAL __http www airconint com
6. or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they are away from the appliance X Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary aa Precautions e Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard e Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock e Do not spray water on indoor unit It may cause electric shock or malfunction e Do not spill water on the remote controller otherwise the remote controller may be broken e Do not repair air conditioner by yourself It may cause electric shock or damage Please contact dealer when you need to repair air conditioner e Do not block air outlet or air inlet It may cause malfunction e f you need to relocate the air conditioner to another place only the qualified person can perform the work Otherwise it may cause personal injury or damage e Do not step on top panel of outdoor unit or put heavy objects It may cause damage or personal injury e Do not extend fingers or objects into air inlet or air outlet It may cause personal injury or damage e Air Conditioner should be properly grounded Incorrect grounding may cause electric shock e Do install the circuit break If not it may cause malfunction e Installation and maintena
7. __T OFF auto operation cool operation dry operation fan operation heat operation SWING swing operation SLEEP sleep operation LOCK lock SPEED set speed Set temperature Set time N P Introduction for buttons on remote controller Note e When power is connected stand by condition you can operate the air conditioner through the remote controller e When unit is on each time you press the button on remote controller the sending signal icon on the display of remote controller will blink once If the air con ditioner gives out a beep sound it means the signal has been sent e When unit is off set temperature will be displayed on the remote controller If the light of indoor unit display is turned on the corresponding icon will be displayed When unit is on it will display the icon of the on going function KJ ON OFF button Press this button to turn unit on off 2 MODE button Pressing this button once can select your required mode circularly as below the corresponding icon lt q will be lit up after the mode is selected AUTO COOL gt DRY gt FAN gt HEAT Only for models with heating function e When selecting auto mode air conditioner will operate automatically according to ambient temperature Set temperature can t be adjusted and won t be displayed either Press FAN button to adjust fan speed e When selecting cool mode air condi
8. button to turn on up amp down air swing J SLEEP button Under Cool Heat mode press this button to turn on Sleep function Press this button to cancel Sleep function Under Fan Dry and Auto mode this function is unavailable TIMER button e When unit is on press this button to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h or 1h Hold or button for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will stop blinking e When unit is off press this button to set Timer On T ON and H icon will be blinking Within 5s press or button to adjust the time for Timer On Pressing or button once will increase or decrease the time by 0 5h or 1h Hold or button for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T ON and H icon will stop blinking e Cancel Timer On Off If Timer function is set up press TIMER button once to review the remaining time Within 5s press TIMER button again to cancel this function Introduction for buttons on remote controller Note e Range of time setting is 0 5 24h e f time changes within 10h the set time will be increased or decreased by 0 5h If time changes from 10h to 24h the
9. set time will be increased or decreased by 1h e The interval between two motions can t exceed 5s otherwise the remote con troller will exit setting status Function introduction for combination buttons Child lock function Press and buttons simultaneously can turn on or turn off child lock function When child lock function is started up LOCK indicator on remote controller is ON If you operate the remote controller remote controller won t send signal Temperature display switchover function Under OFF status press button and MODE button simultaneously can switch between C and F Operation guide 1 2 3 4 5 After putting through the power press ON OFF button on remote controller to turn on the air conditioner Press MODE button to select your required mode AUTO COOL DRY FAN HEAT Press or button to set your required temperature Temperature can t be adjusted under auto mode Press FAN button to set your required fan speed auto low medium and high speed Press SWING button to select fan blowing angle Replacement of batteries in remote controller 1 Press the back side of remote controller on the ay spot marked with and then push out the cover of battery box along the arrow direction 2 Replace two No 7 AAA 1 5V dry batteries and make sure the positions of and polar are correct 3 Reinstall the cover of batte
10. the iG el seed eee wall gt zt wall above bd amp ae above Ve 150mm SIRS O O Sa ue 55mm Rear piping hole Rear piping hole S M ki th iddl tit Li l g val ark in the middle of it g evel meter q Space X We a cobs a ra to the wall above psomm me nag Up e 70mm Rear piping hole Rear piping hole 2 Open a piping hole with the diameter of 955 or 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 18 Installation of indoor unit outdoor Note e Pay attention to dust prevention and take relevant safety measures when opening the hole e The plastic expansion particles are not provided and should be bought locally Step four outlet pipe 1 The pipe can be led out in the l 2 When select leading out the pipe direction of right rear right left or from left or right please cut off the rear left l corresponding hole on the bottom l case l left right l l rear left l cut off the hole Step five connect the pipe of indoor unit 1 Aim the pipe joint at the corresponding bellmouth 2 Le pipe joint union nut pipe 2 Pretightening the union nut with hand i 3 Adjust the torque force by referring to the followin
11. Cm INTERNATIONAL Owner s Manual Split Type Wall mounted Air Conditioner Model ACZCI4H4R18 ACZEM4H4R18 ACZCI4H4R24 ACZEM4H4R24 Thank you for selecting our products For correct operation please read and keep this manual carefully Content Operation Notices Precautions errean eee oe ne ete E a weer E a a ere re teeny ter ae tee etre ere 1 Parts namnen erreien AEE E E re Ganenceoceiaam e E RER 2 Screen Operation Guide Buttons on remote controller ccccccccccceececeeececeeececeeeccssecesaeeeesuseessaneessaeeess 3 Introduction for icons on display screen ccc56 see vecbenacccasstetencnndascsneditecdauedunlacestcesace 3 Introduction for buttons on remote Controller ccccccsssssseeceeceeeeeseseeeeeeeeeeneees 4 Function introduction for combination DuttOns cccccsseeseeeeeeeeeseeeeeeeeeeeeeeaeeees 6 Operation CN Sas erscezese nase sedsennanndeessedkasesdusanacenaatteneses asadadeededecnseeasacsdsandedasseaseobeees 7 Replacement of batteries in remote Controller cccssssseeeeeeceeceeesseeeeeeeeeeneees 7 Emergency operation gemma eeeenetem re meemter er eoremn tere tn tener er mreeetrn or ametemn ts creer te ter 8 Maintenance Clean and MAINTOMANCE os xc cacsccecawncdetntecaeesatcccennne Buaeenteils adel cebu eandeleceddscedcaceoe eco 8 Malfunction Malfunction analysis sss cece csasevenacedansves wudecenctgeccadeeesiss nce iosowaderenadedsasameavianaecssinanees 11 Installation Notice
12. Installation dimension diagram cians sacsiinrons sddsenamasnanasebavsannbbeecenenesanarstuupnacedssnaanesn 15 Tools for installation 00annneeaannnaaannnnnnannnnnnnnnnnenrnnnnnrrrrrnnnrrrnrrrnnnnnrrrennnnrrennrrrnn 16 Selection of installation location cyssecevesiesncdecescsetenddcensere seo ntieeadeuenedoccedeenodeeccazieweds 16 Requirements for electric connection cccccccsseeeeeeeeececceeeeeeeeeeeeeceeaaseseeseeeseeas 17 Installation Installation of indoor unit seseennnnnnninunnnnnnnrrrnnnsnrrrnnnnrrrnrnrrrnssrrrennnnrrrnnnrrrnne 18 Installation of outdoor unit Gaeaee mecca ane Mammentet Sern on Sam ne or eer ects we anne ne cene weir tn 23 Vacuum PUMPING s sirena Ee SSe EE AEE AEAEE ERE EEEE e aR 26 Leakage detection cmcusccacsenaccaisunnnnsaesitccncdunoeaca sami deeeiatameundetimoniitneetcemumamneernnaamnctues 26 Check after installation ioc lt saccscceccscdonsnccsunnsscieacsssamencedanseecesdeeuncetoaadoeseaueerascedansmerceiae 27 Test and operation TeStoperatloN sanean E T E A E 27 Attachment Configuration of connection pipe icc ccccveicansccesseaciskeccssecvesveceeecssscnescbtebcsncnendacieeashees 28 Pipe expanding method ssssoennnesnnnneenttttieerrtttrtnttrntttttrerntttentnrrnnnn rren nnne 30 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision
13. before using the air conditioner 4 Properly connect the live wire neutral wire and grounding wire of power socket 5 Be sure to cut off the power supply before proceeding any work related to electricity and safety 6 Do not put through the power before finishing installation 7 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only Grounding requirement 1 The air conditioner is the first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The appliance must be positioned so that the plug is accessible An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring 6 Including an circuit break with suitable capacity please no
14. ble materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method 10 Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance If the malfunction still can t be eliminated please contact local dealer or qualified professionals Phenomenon Indoor unit can t receive remote controller s signal or remote controller has no action No air emitted from indoor unit Check items Solution e Whether it s interfered severely e Pull out the plug Reinsert such as static electricity stable voltage e Whether remote controller is within the signal receiving range e Whether there are obstacles e Whether remote controller is pointing at the receiving window e Is sensitivity of remote contro ller low fuzzy display and no display e No display when operating remote controller e Fluorescent lamp in room e Air inlet or air outlet of indoor unit is blocked e Under heating mode indoor temperature is reached to set temperature the plug after about 3min and then turn on the unit again e Signal receiving range is 8m e Remove obstacles e Select proper angle and point the remote controller at the re ceiving window on indoor unit e Check the batteries If the power of batteries is too low
15. g sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut with torque wrench 19 Installation of indoor unit open end Hex nut diameter Tightening torque N m wench 6 15 20 union nut 0 9 52 30 40 40755 torque wrench pipe 60 65 indoor pipe 4 Wrap the indoor pipe and joint of con S aN D nection pipe with insulating pipe and m m then wrap it with tape insulating pipe Step six install drain hose 1 Connect the drain hose to the outlet pipe of indoor unit drain hose outlet pipe 2 Bind the joint with tape ye tape Note drain hose e Add insulating pipe in the indoor we drain hose in order to prevent condensation e The plastic expansion particles are not provided meulang pipe Step seven connect wire of indoor unit 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover 20 Installation of indoor unit 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip cj
16. n t affect other people Select a location which is convenient to connect the outdoor unit and near the power socket Select a location which is out of reach for children The location should be able to withstand the weight of indoor unit and won t incr ease noise and vibration The appliance must be installed 2 5m above floor Don t install the indoor unit right above the electric appliance Please try your best to keep way from fluorescent lamp Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborhood The location should be well ventilated and dry in which the outdoor unit won t be exposed directly to sunlight or strong wind The location should be able to withstand the weight of outdoor unit Make sure that the installation follows the requirement of installation dimension diagram Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose Requirements for electric connection Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit and circuit break 3 Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Please install proper power supply cables
17. nce must be performed by qualified professionals Otherwise it may cause personal injury or damage Working temperature range Indoor side DB WB C_ Outdoor side DB WB C 32 23 43 26 Maximum heating 24 18 e The operating temperature range outdoor temperature for cooling only unit is 18 C 43 C for heat pump unit is 7 C 43 C Parts name Indoor Unit air inlet panel filter aux button horizontal louver air outlet cooling power receiver indicator indicator window heating temp drying indicator indicator indicator remote control Display content or position may be different from above graphics please refer to actual products Outdoor Unit air inlet handle air outlet N Notice Actual product may be different from above graphics please refer to actual products Buttons on remote controller TON __T OFF Aa ON OFF button o MODE button ma p button 4 AIk FAN button CFan seee mmer O SWING button QO Q SLEEP button TIMER button Introduction for icons on display screen g i Timeron Timer off I peeetoseeentesen Sending signal T ON
18. on the unit again e Reset the function e Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear e Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature e Set temperature range 16 C 50s e Wait until the voltage resumes normal e Clean the filter e Adjust temperature to proper range e Close door and window Malfunction analysis Phenomenon Check items Solution e Whether there s odour source such as furniture and cigarette Odours are e Eliminate the odour source emitted Air conditio ner operates abnormally Outdoor unit has vapor Water flowing noise Cracking noise etc e Whether there s interference such as thunder wireless devices etc e Heating mode is turned on e Air conditioner is turned on or turned off just now e Air conditioner is turned on or turned off just now 13 e Clean the filter e Disconnect power put back power and then turn on the unit again e During defrosting under he ating mode it may generate vapor which is a normal phenomenon e The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon e This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature Malfunction anal
19. orrectly the parts Is the unit grounded securely It may cause electric leakage Does the power cord follow the speci It may cause malfunction or damaging fication the parts Is there any obstruction in the air inlet It may cause insufficient cooling and outlet heating capacity The dust and sundries caused during It may cause malfunction or damaging installation are removed the parts The gas valve and liquid valve of It may cause insufficient cooling connection pipe are open completely heating capacity Test operation 1 Preparation of test operation e The client approves the air conditioner e Specify the important notes for air conditioner to the client 2 Method of test operation e Put through the power press ON OFF button on the remote controller to start operation e Press MODE button to select AUTO COOL DRY FAN and HEAT to check whether the operation is normal or not e f the ambient temperature is lower than 16 C the air conditioner can t start cooling 2 Configuration of connection pipe 1 Standard length of connection pipe e 5m 7 5m 8m 2 Min length of connection pipe is 3m 3 Max length of connection pipe and max high difference Cooling Pena Max height Cooling Ma enad Max height of connec of connec capacity tion pipe difference Capacity tion pipe difference 5000Btu h 1465W 15 7000Btu h 7 2051W 9000Btu h ae 2637W 12000Btu h a 3516W 18000B
20. p between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and closed to the wall indoor outdoor upper hook wall pipe LIF LLA Z 77 lower hook of wall mounting frame Note e Do not bend the drain hose too excessively in order to prevent blocking 22 Installation of outdoor unit Step one fix the support of outdoor unit select it according to the actual installation situation 1 Select installation location according to the house structure 2 Fix the support of outdoor unit on the selected location with expansion screws Note e Take sufficient protective measures when installing the outdoor unit e Make sure the support can withstand at least four times of the unit weight e The outdoor unit should be installed at least 3cm above the floor in order to install drain joint e For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 1OOOOW at least 3cm above the floor 16000W 10 expansion screws are needed Step two install drain joint Step three fix outdoor unit Only for cooling and heating 1 Place the outdoor unit on the unit l support 1 Connect the outdoor drain joint into 2 Fix the foot holes of outdoor unit the hole on the chassis as shown in g Wi
21. ry box cover of battery box e During operation point the remote control signal sender at the receiving window on indoor unit e The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them e Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone remote controller should be close to indoor unit during operation e Replace new batteries of the same model when replacement is required e When you don t use remote controller for a long time please take out the batteries e f the display on remote controller is fuzzy or there s no display please replace batteries Emergency operation If remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner The operation in details are as below As shown in the fig Open panel press aux button to turn on or turn off the air conditioner When the air conditioner is turned on it will operate under auto mode aux button Clean and maintenance m Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock m Do not wash the air conditioner with water to avoid electric shock m Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommended to use a soft dry cloth or
22. status for 1 2min to check if the pres sure of piezometer remains in 0 1MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent 7 Reinstall the handle Leakage detection 1 With leakage detector Check if there is leakage with leakage detector 2 With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and keep the soap water for more than 3min If there are air bubbles coming out of this position there s a leakage piezometer gas valve valve cap 26 Check after installation e Check according to the following requirement after finishing installation Items to be checked Possible malfunction Has the unit been installed firmly The unit may drop shake or emit noise Have you done the refrigerant leakage It may cause insufficient cooling test heating capacity Is heat insulation of pipeline sufficient l ME CARRE ongensanom And weater dripping ie watr dined wei It may cause condensation and water dripping Is the voltage of power supply accord ing to the voltage marked on the It may cause malfunction or damaging nameplate the parts Is electric wiring and pipeline installed It may cause malfunction or damaging c
23. te the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit Circuit break capacity 18K cooling only model 20A O oR OU 20A 18K cooling and heating model 17 Installation of indoor unit Step one choosing installation location Recommend the installation location to the client and then confirm it with the client Step two install wall mounting frame 1 Hang the wall mounting frame on the wall adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall 2 Drill the screw fixing holes on the wall with impact drill the specification of drill head should be the same as the plastic expansion particle and then fill the plastic expansion particles in the holes 3 Fix the wall mounting frame on the wall with tapping screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby Step three open piping hole 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below 18K all Wall Mark in the middle of it o Level meter N Space Tt m Space YX D cofee e Ae fe ojs q to the ia A to
24. th bolts the picture below i foot holes 2 Connect the drain hose into the drain vent I I I iia I Q e l drain vent chassis i foot holes outdoor drain joint Drain hose l 23 Installation of outdoor unit Step four connect indoor and outdoor pipes 3 Pretightening the union nut with hand 1 Remove the screw on the right han dle of outdoor unit and then remove the handle Bw handle aim the pipe joint at the bellmouth of pipe wrench by referring to the sheet below Hex nut diameter lightening torque N m 6 1520 9 52 30 40 40 55 60 65 70 75 gas valve I I I I I I 2 Remove the screw cap of valve and l 4 Tighten the union nut with torque I I I I I I I Step five connect outdoor electric wire 1 Remove the wire clip connect the power connection wire and signal control wire only for Cool and heat type to the wiring terminal according to the color fix them with screws ole e o lefe M aH HN PUNAN ip Mi NN IN o Indoor unit connection 24 Installation of outdoor unit 2 Fix the power connection wire and signal control wire with wire clip only for cooling and heating unit Note e After tighten the screw pull the power cord slightly to check if it is firm e Never cut the power connection wire to prolong or shorten the distance Step six neaten the pipes CTY ae
25. tioner will operate under cool mode Then press or button to adjust set temperature Press FAN button to adjust fan speed e When selecting dry mode air conditioner will operate at low fan speed under dry mode In dry mode fan speed can t be adjusted e When selecting fan mode air conditioner will operate in fan mode only Then press FAN button to adjust fan speed e When selecting heat mode air conditioner will operate under heat mode Then press or button to adjust set temperature Press FAN button to adjust fan speed Cooling only unit can t receive heating mode signal If set HEAT mode by remote controller press ON OFF button can t turn on the air conditioner 3 button e Pressing or button once will increase or decrease set temperature by 1 F C Hold or button for 2s set temperature on remote controller will change quickly Release the button after your required set temperature is reached e When setting Timer On or Timer Off press or button to adjust the time See TIMER Button for setting details Introduction for buttons on remote controller 4 FAN button Pressing this button can select fan speed circularly as AUTO SPEED 1 a SPEED 2 at SPEED 3 aal SPEED 4 cas eT eer eee Note e Under Auto speed air conditioner will select proper fan speed automatically according to ambient temperature e Fan speed can t be adjusted under Dry mode 5 SWING button Press this
26. tu h 5274W 24000Btu h 7032W 28000Btu h 8204W 36000Btu h 10548W 42000Btu h 12306W 48000Btu h 14064W 25 30 30 10 10 20 20 4 The additional refrigerant oil and refrigerant charging required after prolonging connection pipe e After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5ml of refrigerant oil for each additional 5m of connection pipe e The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe x additional refrigerant charging amount per meter e When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet 28 Configuration of connection pipe Additional refrigerant charging amount for R22 R407C R410A and R134a Pipe expanding method Note Improper pipe expanding is the main cause of refrigerant leakage Please expand the pipe according to the following steps A Cut the pipe e Confirm the pipe length according to the distance of indoor unit and outdoor unit e Cut the required pipe with pipe cutter E Expand the port e Expand the port with expander vx X xX 90 leaning uneven burr w vA eK J au v3 v3 Note e A
27. wet cloth to wipe it Note e Do not remove the panel when cleaning it Clean and maintenance Clean filter Open panel Clean filter Pull out the panel to a certain e Use dust catcher or water to angle as shown in the fig clean the filter e When the filter is very dirty use the water below 45 C to clean it and then put it in a shady and cool place to dry Remove filter Remove the filter as in dicated in the fig Install filter Install the filter and then close the panel cover tightly m The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased m After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard Clean and maintenance Checking before use season Check whether air inlets and air outlets are blocked Check whether circuit break plug and socket are in good condition Check whether filter is clean Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Check whether drainage pipe is damaged Checking after use season Disconnect power supply Clean filter and indoor unit s panel Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recycla
28. ysis Error Code e When air conditioner status is abnormal temperature indicator on indoor unit will blink to display corresponding error code Please refer to below list for identific ation of error code Above indicator diagram is only for reference Please refer to actual product for the actual indicator and position me of ES O s door display Error code Error code Troubleshooting Heating indicator ON 10s OFF 0 5s E5 H6 C5 F1 F2 Ae Note If there re other error codes please contact qualified professionals for service Warning m When below phenomenon occurs please turn off air conditioner and discon nect power immediately and then contact the dealer or qualified professionals for service e Power cord is overheating or damaged e There s abnormal sound during operation e Circuit break trips off frequently e Air conditioner gives off burning smell e Indoor unit is leaking m Do not repair or refit the air conditioner by yourself m If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Installation dimension diagram Space to the ce 4 Space to the floor Spaceto th obstruction Mt least 30cm Hh Space tothe wall
Download Pdf Manuals
Related Search
Note notepad++ notes notebook lm notes app notebookcheck notepads notepad app notes ai notepad++ download notebook lenovo notepad online note taking apps note taker notebook llm noteflight note gpt notebook lm google notes apple notes online notepad program notebook app notepad++ online notepad free notebook paper notebook ml
Related Contents
Zen Music Servers Manual de usuario - Electrónica Embajadores, Tienda de Measure Data Acquisition User Manual Sony SAT-A4 User's Manual Manual de utilização Mode d`emploi Balance d`analyse AE166 DeltaRange Model DO70G Optical Dissolved Oxygen Sensor user manual télécharger le planning en pdf Copyright © All rights reserved.