Home
User`s MANUAL - avic security
Contents
1. USER Extra Options Assigned Extra Options Assigned Extra Options Assigned Goma CP eme ESNS oE CUD NOR once 1 Mest P201E 20 P220E 2 P202E 21 P221E 3 P203E 22 P222E 4 P204E 23 P223E 5 P205E 24 P224E 6 P206E 25 P225E 7 P207E 26 P226E 8 P208E 27 P227E 9 P209E 28 P228E 10 P210E 29 P229E 11 P211E 30 P230E 12 P212E 31 P231E 13 P213E 32 P232E 14 P214E 33 P233E 15 P215E 34 P234E 16 P216E 35 P235E 17 P217E 36 P236E 18 P218E 37 P237E 19 P219E 38 P238E Ness D8x D16x Controt Paner User s Manual eal KEYPAD OPERATION SU MMARY Operation by KEYPAD to ARM The panel must initially be disarmed to DISARM To disarm and or reset alarms to arm HOME MODE The panel must initially be disarmed See page 12 for more information on arming Home Mode PANIC alarm KEYPAD DURESS Keypad Duress allows the user to send a silent duress report while disarming if the system is being monitored by a central station EXCLUDE ZONES EXCLUDE E can only be used when the panel is disarmed EXCLUDE CODE E can be used any time Press If the Arming Shortcut is enabled or press User Cope or press User Cope If Code Only Arming has been enabled for that user code Press User Cope Press If the Home move SHortcut is enabled or press User Code Press both C Panic keys together Press
2. DISPLAY TEST To display all the keypad icons press and hold the button for at least 2 seconds All the icons will be on while the button is held down Display Test can be activated at any time either in operating mode or any program mode 6 Ness D8x D16x Controt Paner User s Manual KEYPAD DISPLAY INDICATORS IN OPERATING MODE KEYPAD ICON DISPLAY ZONES 1 8 or 1 16 Zone is sealed KEYPAD INDICATORS Zone is unsealed Zone is in alarm OK READY TO ARM Zone s are unsealed or Power fault or Panel is armed or phone line fault Ready to Arm Panel is disarmed Panel is armed a ARMED or Area 1 is disarmed if or Area 1 is armed if using Areas using Areas Area 2 is disarmed Area 2 is armed if using A ARMED Areas Ti HOME Home Mode is Panel is armed in Home Day Mode enabled see disarmed Mode page 20 2 Normal Memory mode selected New alarm s in memory MEMORY Normal Receiving a radio signal A Radio Key or other If radio fitted radio device has low battery Normal Internal Tamper Double Flash with long pause TAMPER External Tamper Steady flash Ge Normal Zone s are Excluded EXCLUDE Normal The backup battery LOW is low BATTERY Normal Mains power is off MAINS OFF Normal User Program Mode Installer Program Mode PROG Normal Dialler is on line Phone line fault or d LINE failure to
3. The beeps will continue during the AutoTime warning period changing to faster beep in the final minute prior to the AutoTime event The panel re arms itself a short time after disarming Auto Re Arm is enabled Enter the premises after disarming Auto Re Arm is designed to re arm the panel if you don t enter the premises after disarming Eq Ness D8x D16x Controt Paner User s Manual INSTALLATION RECORD D 3 D ic BALLER SECURITY ALARM PANEL NESS D8 ALARM CONTROL PANEL NESS D16 ALARM CONTROL PANEL TIMERS User programming options DIALLER SECURITY ALARM PANEL DATE PURCHASED DATE INSTALLED P26E ENTRY DELAY TIME 1 P27E ENTRY DELAY TIME 2 P28E EXIT DELAY TIME P29E SIREN RESET TIME DEVICE TYPE PIR Reed switch etc DESCRIPTION Entrance bedroom1 etc INSTALLATION COMPANY TELEPHONE MONITORING COMPANY TELEPHONE ZONE ASSIGNMENT Installer programming options Seconds Seconds Seconds Minutes P41E ENTRY DELAY 1 P43E ENTRY DELAY 2 P42E HANDOVER P40E INSTANT P45E AREA 1 P46E AREA 2 P54E RESET OUTPUT P51E MONITOR P52E 24 HOUR P55E STROBE OUTPUT P56E SONALERT OUTPUT P57E SIREN OUTPUT P74E Report dialler D8 amp D16 oinioja a jjv ja
4. 00 and 63 2000 2063 P345E DAY OF THE WEEK Enter a value between 1 and 7 1 Sunday 3 New VaLuE Enter the new time in The new time will be dis seconds Example enter 25 played by the keypad one seconds as 25 E digit at a time 4 To exit User Program Mode a Program light will turn Set the current date and time to ensure that AutoTime events take place as expected You will need to adjust the Hours setting when Daylight Savings starts and ends Clock memory is retained on power down 24 Ness D8x D16x ControL Paner User s Manual CENTRAL STATION MONITORING The Ness D8x and Ness D16x control panels have an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who arm and disarm the system AUDIBLE MONITORING As a lower security alternative to central station monitoring the panel can be pro grammed to send audible messages to a fixed or mobile phone When programmed for audible monitoring the pane calls a pre programmed number or numbers and sounds an audible alarm mes sage and a series of beeps over the phone These beeps can identify the zone or zones which caused the alarm and well as several other alarm types THE A
5. Exit Timer programming ccceseeeeeeeees 23 Telephone Number programming 23 Real Time Clock programming ccseeeeeeeeees 24 Monitoring Central station Audible 00 25 Remote operation by telephone eee 26 27 Ness ACCESSOMES i iisciisssscinsavecsasacatusvacacdstescaniacat 28 29 Troubleshooting 5 cocnicenaseecessgetepeeeepepasuarensccetaacecsnneaene es 30 Installation RECOM 0 0 ee eeseeeseeeeeeeeneeteneeeeneeeeneeeee 31 OPERATION SUMMARY 0 eects eeeeeeeees 32 NESS D8x AND D16x FEATURES e 8 or 16 alarm zones D8x D16x e Supports up to 3 remote LCD keypads e 56 user codes can be programmed to operate by keypad PIN radio key or access card e Optional Ness Radio Interface for fully integrated wireless security e Programmable 2 Area partitioning can split the panel into two independent areas plus a common area e Real Time Clock with AutoTime features Automatically arm disarm and control auxiliary outputs on a daily or weekly basis e 3 Door Access Controller onboard with support for Weigand prox or fingerprint readers e Home Mode allows partial arming eg perimeter security overnight e Day Mode feature allows daytime monitoring of fire doors coolrooms etc e Temporary Day Zone feature allows easy enabling disabling of Day Mode e Keypad Panic feature e Keypad Duress feature e Two button arming feature e Fire Alarm feature with different s
6. Jauto NOW WITH TIME Dex eX VE Ness D8x D16x ALARM CONTROL PANEL USER S MANUAL A 15 00 Revision 6 2 Quality Endorsed Company 1809001 Lice aec2074 NSW Hiesa Gee only INEZ Security Products Wwww ness com au MADE AUSTRALIA Le v Australia s largest designer and manufacturer of high quality security products N CE WARNING Installation and maintenance shall be performed by qualified service personnel only CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions on the battery COPYRIGHT NOTICE Head Office Ness Security Products Pty Ltd ABN 28 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Admin Fax 61 2 9838 8508 ness ness com au SYDNEY Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au MELBOURNE Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au BRISBANE Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au PERTH Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au ADELAIDE Ph 08 8152 0000 Fax 08 8152 0100 adelaide ness com au D8X D16X USER MANUAL Rev 6 2 Nov09 Document Part Number 890 006 ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in all premises with an
7. a detector you can Exclude the associated zone so that it is totally ign ored and cannot generate an alarm Including the zone will enable it to generate an alarm again The control panel is fitted with a rechargeable backup battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery Test All alarms are stored in memory and can be viewed at any time in Memory Mode 1 Keypad codes programmed as Arm OnLy will not reset the panel 2 Access Cards Fobs can reset the panel if the Disarm By Access Carp option has been enabled by your installer Ness D8x D16x Controt Paner User s Manual E KEYPAD The D8x and D16x control panels are supplied with an LCD Keypad which provides important visual and audible indications and is the main interface for operating and programming the control panel Up to three keypads can be connected to a D8x or D16x panel KEYPAD BEEPS BEEPS MEANING Al 1 BEEP Any key press eee 3 BEEPS Valid Command oe e 1 LONG BEEP Error 10 10BEEPS Mains Power is off or Panel Battery is low or A Radio Device has sent a low battery signal or Telephone Line Fail has been detected pala hi An AutoTime action is Constant SLOW beeps UE to begin AAA An AutoTime action Constant FAST beeps wl begin in one minute
8. and professional digital cameras Video monitors are available in CRT or flat screen LCD styles in sizes to suit all applications Ness acclaimed Digital Video Recorders store video footage on hard disk drives for fast and easy to retrieve tapeless recording Ness DVRs are available in 4 6 9 and 16 channel models to suit all applications and all budgets even mobile models for use in vehicles such as buses and trucks Most DVR models are Internet Ready for instant connection to a LAN and broadband internet connection for remote viewing Ness CCTV means Consistent Commitment To Value 28 Ness D8x D16x Controt Paner User s Manual OPTIONAL RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door Ness Radio Keys provide the benefits of separate ON OFF and PANIC buttons as well as optional control of auxiliary outputs all in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel RK4 RK3 Radio Key Radio Key RADIO KEYS Fully waterproof ultra slim 3 or 4 button Radio Keys for remote control of the control panel With separate buttons for ON Arm OFF Disarm PANIC and AUX functions RK4 only Including long life lithium batter
9. and Area2 The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Areai1 and Area2 are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Area1 or Area2 Disarms AREA OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the Armed state This means that Day 24hr and Home zones are independent of the area operations Note Area partitioning is in addition to Home Mode Any zone may be allocated to any area ea Ness D8x D16x Controt Paner User s Manual 100 664 100 067 Ness RK3 Ness RK4 Radio Key Radio Key OPERATION NESS KPX LCD KEYPAD The Ness LCD keypad uses a large illuminated LCD display to show system and zone status The large easy to read buttons are backlit for and a hinged flap covers the keys The LCD icon displ
10. communicate See page 16 for keypad indicators in Memory Mode Ness D8x D16x Controt Paner User s Manual EA OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the keypad You may also have optional Radio Keys or Access Control equipment installed OPERATING RULES Generally the panel will be Disarmed Armed and Home modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any codes press the Enter or E button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt the alarm is activated requiring the correct code E to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA PARTITIONING Area Partitioning allows the zones to be split into two partitions Areal
11. up 2 Wait 10 seconds then dial the telephone number again The panel will answer immediately and gives a 2 second beep followed by low tone 3 PRESS 0 To prepare the panel ddd 3 beeps 4 PRESS User Code to authorise the next command ddd 3 beeps 5 PRESS 4 to arm the panel ddd 3 beeps 6 PRESS B to finish and hang up Ness D8x D16x Controt Paner User s Manual Ba NESS ACCESSORIES and i nu mungpe CELI Coa Ate waa ae AGATA 7 NESS QUANTUM DETECTORS The Ness Quantum range of high tech motion detectors includes passive infrared detectors dual technology microwave and infrared as well as ceiling mounted 360 detectors All Ness detectors are designed and manufactured using the most modern technology and techniques to ensure superior reliability and performance The Ness Quantum Pet Aware PIR and Pet Aware Dual have a superior ability to discriminate between household pets and unwanted human intruders Ness Pet Aware detectors make it possible to protect your premises with your pets indoors Up to 25kg animal Pen AUSTRALIA Le v WF onsistent WA ommitment bdo Wue CCTV Products NESS CCTV PRODUCTS The wide range of Ness CCTV equipment allows your installer to design a professional state of the art system for your home office shop or factory Ness cameras include dome cameras Infra red illuminated cameras miniature hidden cameras
12. while you are at home Your installer must program which zones will be active in Home mode If an alarm occurs while in Home mode entering User Code E will silence the alarm This will also Disarm the panel so remember to re arm Home mode again if needed Using the optional Radio Keys you can enter Home Mode by pressing either the OFF button or the ON button twice within 4 seconds or by pressing the AUX button RK4 radio key only These options must be enabled by your installer oe OF KaT Press either the OFF button or the ON button twice within 4 seconds Or press the AUX button once lf enabled RK4 radio key only The strobe light will flash briefly If required your installer can program the external siren to chirp twice when arming Home mode Note Home Mode and Area arming Home Mode can be used if the panel is fully disarmed or if only Area2 is armed Home Mode is not available when Area 1 is armed The panel can be armed in Home mode if Area2 is already armed on these conditions e Area 1 must be OFF e Area 2 must be armed first and then Home Mode armed not the reverse e Zones assigned to both Home mode and to Area 2 will act as Home Mode zones when both Area 2 and Home Mode are armed Note Home Mode arming when Area2 is armed cannot be done by Radio Key or by keyswitch A Ness D8x D16x Controt Paner User s MAnuaL OPERATION PANIC alarm by KEYPAD Pre
13. 5 6 8 or 9 User Cope Add one these digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler to the central station Rerort Keyrap Duress must be enabled Press lf the Exctupe SHortcut is enabled then Zone No Zone No Enter the zone number s to be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed If a user code is assigned to a radio key and has Extra Option 4E enabled Cope ONLY ARMING then pressing OFF toggles the panel arm disarm state
14. Codes are Keypad Codes by default User Codes can be programmed to be Radio Codes or Access Cards as required Ask your installer NOTES 1 A User codes must NOT start with zero The panel will allow codes beginning with zero to be programmed but they will not operate the panel This is an alternative method for disabling user codes 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected 3 When re programming a Keypad Code the old code does not need to be deleted first The new 22 Ness D8x D16x ControL Paner User s MAnuaL PROGRAMMING Programming TIMERS STEP KEYSTROKES DESCRIPTION COMMENT 1 P MasteR Cope Enters User Program Mode The Program light will turn on 2 4 Enter the option number for The existing time if any will DG Entry Delay Time 1 be displayed by the keypad one digit at a time or fs Or enter the option number for OW Entry Delay Time 2 or 4 Or enter the option number for Oo Exit Delay Time 3 New Time Enter the new time in seconds The new time will be dis Example enter 25 seconds as played by the keypad one 25 E digit at a time 4 P To exit User Program Mode hy Program light will turn Factory default timer settings are listed on page 21 Programming the FOLLOW ME TELEPHONE NUMBER STEP KEYSTROKES
15. D or FOB Present a Card or Fob twice Or present a Card or Fob once press button Depending on which option has been enabled The Armen light will turn on by your installer Leave the premises within the Exit Delay Time 3 beeps will sound at the end of Exit Delay Time The control panel must be armed in order to detect intruders Before arming all zones should be Sealed by making sure there is no movement in rooms protected by motion detectors Doors or windows protected by reed switches should be closed The panel cannot be armed if in Program Home Monitor Memory or Exclude modes or if it is in alarm User codes that are programmed to be Arm Only codes can arm the panel either the disarmed state or from Home Mode A keypad is supplied with the panel Operation by Radio keys and access cards is optional J J10fL 10 beeps when you arm means Mains Power is turned off or the backup battery is low d J L One long beep when you arm could mean the panel is already armed or the keypad code is wrong if not using Shortcut Arming SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds to indicate that those zones have been automatically excluded You should disarm the panel check the premises and then arm again Continual warnings could mean there is a problem with a detection device that zone may have to be manually exclu
16. DESCRIPTION COMMENT 1 P Master Cope Enters User Program Mode The Program light will turn on 2 Enter the option number for Fol The existing telephone E OW low Me Telephone Number number if any will be dis played by the keypad one digit at a time 3 New TELEPHONE Numsen E Enter the new telephone The new telephone number number if any will be displayed by the keypad one digit at a time 4 Ers To exit User Program Mode be Program light will turn off The Follow Me telephone number is only used in Audible Dialling mode If the Follow Me number is programmed then the primary amp secondary numbers are ignored Ask your installer for further information Ness D8x D16x Controt Paner User s Manual E PROGRAMMING Programming REAL TIME CLOCK STEP KEYSTROKES DESCRIPTION COMMENT 1 P Master Cove E Enters User Program Mode The Program light will turn on 2 i ims Enter the option number for The existing value if any g OOU one of the real Time Clock will be displayed by the P340E MINUTES Enter a value options keypad one digit at a time between 00 and 59 P341E HOURS Enter a value between 00 and 23 P342E DAY OF THE MONTH Enter a value between 01 and 31 Ensure that the setting does not exceed the days in the current month The panel does not cross check this setting P343E MONTH Enter a value between 01 and 12 P344E YEAR Enter a value between
17. Day zone Before leaving the premises you must Arm turn on the panel After arming the panel will ignore detectors during the Exit Delay Time to allow you to exit without triggering an alarm The system can be armed and disarmed using the keypad supplied or by optional Radio Keys or Access Cards or Fobs When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm unless you disarm the panel during this allowed time INTRODUCTION When an alarm occurs it can be reset with a User Code or by optional Radio Key or Access Card Fob otherwise it will reset at the end of Alarm Reset Time Resetting an alarm stops the sirens and strobe light If an alarm is not reset the sirens will stop after the programmed time default is 5 minutes and the strobe light will stop after 72 hours Home Mode also called Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is used Radio Keys can also Arm and Disarm Areas The control panel housing and the covers over external sirens are protected by tamper switches to detect someone attempting to disable the security system Activation of these switches will cause an instant tamper alarm If there is a problem with
18. IO SMOKE DETECTOR The Ness Radio Smoke Detector z provides a fully wireless smoke h SA detection option which can trigger i the panel s siren s and dialler if required or as programmed by your installer The Ness Radio Smoke Detector uses Photo electric smoke detection technology On board sounder and test button for the sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery Ness D8x D16x Controt Paner User s Manual 29 TROUBLESHOOTING SYMPTOM When arming a zone light is on or the keypad gives a long beep POSSIBLE CAUSE One or more detection device a PIR or reed switch may be unsealed REMEDY Find the cause of movement or close the door or window e 10 beeps from keypad e MAINS light is flashing e BATTERY light is flashing The mains power may be off or the panel s backup battery may be low or a Radio Device battery may be low Make sure the plug pack is plugged in and the power point is turned on The backup battery may need replac ing call your installer 1 long beep from the keypad Invalid keypad entry Press the E button and try again 2 second siren at the end of Exit Delay time A zone was unsealed at the end of exit delay time Disarm the panel and check all zones The strobe light is flashing There has been an alarm within the last 72 hours Reset the alarm by disa
19. UDIBLE MESSAGE When triggered by an alarm the panel will dial the programmed telephone number s and output the audible message ALARM ALARM ALARM and beeps for 45 seconds or until it is acknowledged THE FOLLOW ME TELEPHONE NUMBER If your panel is programmed for Audible Monitoring it will make alarm calls to the Primary and Secondary telephone numbers programmed by your installer If a Follow Me Telephone Number is pro grammed the Primary and Secondary tel ephone numbers will be ignored All alarm calls will be sent to the Follow Me telephone Number If your panel is monitored by a Central Station the Follow Me number is ignored MONITORING Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system For further information about 24 hour monitoring contact your installer or Ness Security Products ACKNOWLEDGING THE ALARM The person receiving the call can acknowledge the alarm by pressing the key on their telephone Press the key during gaps in the alarm message Once you successfully acknowledge the alarm the panel will hang up and not ring any other telephone numbers If you do not acknowledge the alarm the panel will ring you again and then it will ring the next programmed telephone number if any Note If the alarm is not acknowledged the LINE light on the keypad will flash continuously until the panel is next armed Ness D8x D16x Co
20. alarm dialler installed All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2009 Ness Security Products Pty Ltd ABN 28 069 984 372 CONTENTS FOAtUNGS vez tacisei fecreca tues ceaeteres ain scrnastaqutenaate tenets madame 4 INtMOGUCTION tecnica ete ee ities 5 ROY DAG iriiria dee iiei 6 Visual Indians racinieneiis ahead canes 7 OPERATION wesiittacehieceteitet tere dt ada ecceeeeees 8 9 e os se nd N E E 10 DISANMING ssania n n 11 Home Monitor Mode s 12 Keypad Panl Ciarain aR 13 Keypad DUTESS oraiiio n nadia nies 13 Keypad Fire Alarm ceeceecceeeseeeseeteeeeeeneeeeneereneees 14 Keypad Medical Alarm ssseeeeereernen 14 Excl ding ZONES wesc scccaceetcescicpisieieccessecesaceteste erent cees 15 VIEW MEMON iioii 16 Temporary Day ZONES sereen 17 AutoTime Features 2 0 0 eeeeeeeeeseeeeseeeeeneereneersneees 18 AutoTime Operation ceseeeeeeeeeeeetteeeeeeeeeeeeeees 19 PROGRAMMING ecceesceeeeeeeeeeeeeeeeeneeseeeaeeneeeneetaes 20 Programming Options Table ceeeeeeeeeeees 21 User Code programming eceesceseeeeeeeteeees 22 Entry
21. ay can only be selected while the panel is in the Disarmed state TO CLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stops flashing after the memory is viewed as shown above and the MEMORY light is automatically cleared next time the panel is Armed When reviewing the event memory the keypad lights will show the stored events as shown in this table KEYPAD DISPLAY INDICATORS IN MEMORY MODE KEYPAD ICON MEMORY EVENT Zone numbers 1 8 or 1 16 Zone alarm no icons displayed Panel Disarmed ARMED Panel Armed or Area 1 Armed ARM2 Area 2 Armed MAINS Mains power failure BATTERY Low Battery TAMPER 1 Internal Tamper alarm TAMPER 2 External Tamper alarm EXCLUDE Panic alarm LINE Telephone line fail RADIO EXCLUDE Radio Key Panic alarm RADIO BATTERY ZONE Radio Device battery low Device number is indicated by zone lights RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by zone lights RADIO HOME ZONE Radio Supervision alarm Device number is indicated by zone lights HOME ZONE Wired Zone Supervision alarm Zone number is indicated by zone lights 16 Ness D8x D16x ControL Paner User s MAnuaL The Ness D8x and D16x have a Temporar
22. ay provides information on zone condition armed state mains and battery condition and other information Supplied with the D8x and D16x panels Also available separately NESS RADIO KEYS The optional Ness Radio Keys give you the convenience of remote control operation Multi button operation allows you to Arm Disarm and activate PANIC The RK4 Radio Key can also be programmed by your installer to activate an auxiliary output on the control panel NESS ACCESS CONTROL D8x and D16x also have an access control option for arming disarming and controlling electric door locks The panels have built in software and hardware support for up to 3 Ness Weigand proximity card readers and up to 55 proximity cards or fobs Note Radio Keys and Access cards and readers are optional and are not supplied with any Ness control panel as standard Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel Ness D8x D16x Controt Panet User s MANUAL OPERATION TO ARM the panel by KEYPAD Press E If the Armine SHortcut is enabled or press User Cone E or press User Cope If Cope Onty ArminG has been enabled by your installer by RADIO KEY Press the ON button once The strobe light will flash briefly If programmed the external siren will chirp once If Home Arming by Radio Key is enabled the chirp will be delayed by 5 seconds by ACCESS CAR
23. ded If a zone is Unsealed at the end of exit time and the auto exclude option is disabled the siren will sound for the duration of siren time default is 5 minutes 10 Ness D8x D16x ControL Paner User s Manual OPERATION to DISARM the panel by KEYPAD Enter the premises through a Delay Zone Press User Cope E The ARMED light will turn off When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to disarm the panel If the panel is not disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may disarm your system from within your premises or from outside your entrance door There is also the option to Chirp the outside siren three times and briefly flash the strobe light to indicate that you have disarmed your system If you make a mistake when entering your keypad code then you must press E or Enter and start again Five incorrect entries will cause an alarm The panel can be reset and the siren s silenced by disarming the panel If you arrive at your premises and find the strobe light flashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode by RADIO KEY Press the OFF button once The strobe light will flash briefly If required
24. e is a problem with a detection device and the zone cannot be sealed when arming the panel then that zone can be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously while the panel is Disarmed and also when Armed Zones can be excluded while the panel is either Disarmed or Armed See notes below NOTES Zone Exclude is not permanent Excluded zones are automatically included next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the Zone No E sequence to turn OFF the zone lights to be Included EXCLUDE E works only when the panel is Disarmed e EXCLUDE User Code E works in any state e EXCLUDE User Code E can only exclude the zones in the Area assigned to that code Ness D8x D16x Controt Paner User s Manual 15 OPERATION Viewing the EVENT MEMORY by KEYPAD Press If the View Memory SHortcut is enabled or press User Cone The Memory light will turn on Press The most recent event will be displayed Press The next most recent event will be displayed Press and so on up to 30 events Press E to exit Memory Mode The panel stores a comprehensive event memory including Arming Disarming Low Battery Mains Fail and Alarm events The memory is constantly upgraded and the last 30 events are always available for viewing This memory displ
25. e you need to know your Master Code which is user code number 1 see the table on the next page TO ENTER PROGRAM MODE press P Master Cove E The factory default Master Code is 123 TO EXIT PROGRAM MODE press P E The panel will automatically exit Program Mode if the keypad is inactive for 4 minutes USER CODES The panel has 56 user codes which can be operated by keypad code 3 6 digit PIN by optional radio key or by optional access cards To add change or delete a keypad code follow the steps on page 22 The factory default Master Code is 123 You should re program this code with a new code of your own choice TIMERS You can also re program the Entry Delay Time and Exit Delay Time if you need more or less time to exit and enter the premises REAL TIME CLOCK Some features such as AutoTime rely on the onboard Real Time Clock Set the current date and time to ensure events take place as expected You will need to adjust the Hours setting when Daylight Savings starts and ends TELEPHONE NUMBER If your panel is programmed for Audible Monitoring the panel s dialler will make alarm calls to the Primary and Secondary telephone numbers programmed by your installer If a Follow Me Telephone Number is programmed the Primary and Secondary telephone numbers will be ignored All Audible Alarm calls will be sent to the Follow Me telephone Number This is handy if yo
26. ermanent Day Zones can be selected as Temporary Day Zones but this has no effect as those zones are already day zones Exit Selection Mode Saves changes and returns to normal operating mode Enable Day Mode ORG This enables disables both Temporary and Permanent Day Zones When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone Q The MONITOR icon flashes continuously when Temporary Day Mode is enabled Ness D8x D16x ControL Paner User s Manual A OPERATION AUTO TIME FEATURES D8x D16x V6 onwards features sophisticated new automation features making full use of the onboard Real Time Clock and a set of powerful yet simple to program options I AUTO TIME amp ARMED ARMED Ti HOME ARM or DISARM AUTOMATICALLY at pre programmed times of day or day of the week This feature can save a site manager many headaches and hours of travel time There is no need to rely on staff remembering to arm or disarm the system TURN AUX OUTPUTS ON or OFF at pre programmed times every day once a week anytime Automate doors sprinkler systems lights and more ENABLE DISABLE USER CODES depending on the time of day or day of the week Allows managers to grant users access to the system at selected times and deny after hours entry If you find that the panel
27. iren tones e Highly flexible zone to output mapping e Multiple programmable EOL resistor values from Ok to 22k An installer s favourite e Onboard Vibration Sensor Analyser with programmable sensitivity Use with Nessensor vibration sensors e Siren chirp and strobe flash on arming with radio key e Quiet chirps option on arm disarm by radio key e True Dynamic Battery Test actively tests the battery under load every hour e 4 programmable auxiliary outputs can be operated automatically by AutoTime or manually by keypad e Enhanced serial data input output via RS232 Interface with third party products e Automatic reset fuses no glass fuses to replace e Programmable siren reset lockout complies with noise regulations e 30 event memory can be reviewed by keypad e Easy programming by keypad or NessComms software e All programming data is permanently stored in a non volatile memory e All inputs and outputs are heavily protected against lightning and high voltage supply transients e Optional output expander for even more auxiliary outputs DIALLER e Full remote upload download by PC and modem using NessComms software e Remote control of outputs by telephone e Arm disarm remotely by telephone e Contact ID Format for central station monitoring Supports two 14 digit phone numbers plus one follow me number for audible monitoring e Audible Voice reporting feature e Ph
28. ntrot Paner User s Manual 25 REMOTE OPERATION The D8x D16x will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux outputs 1 2 3 or 4 To maintain panel security remote operations can only be activated after entering a valid user code To operate the panel by telephone you need a DTMF capable telephone a valid user code and you must know the telephone number of the line to which the panel is connected NOTES e If the panel does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up e If an alarm occurs which requires the panel to dial out while attempting remote control the panel will treat the alarm as a priority give a constant tone as a warning and then hang up e When all remote control commands are finished press to force the panel to hang up SEQUENCE OF OPERATION 1 Phone the panel telephone number and listen for the required number of rings and then hang up Wait 10 seconds and then call the number again within 50 seconds The panel will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The panel is now ready to receive telephone commands Press the 0 button on the telephone This tells the panel that telephone commands will follow The panel will resp
29. ond with either 3 beeps if all OK One long beep means try again Now enter a valid User Code that is normally used for Arming or Disarming the panel followed by the button The panel will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again Enter the required command See the summary of telephone commands on the next page Press i to finish This tells the panel to hang up Also hang up your telephone 26 Ness D8x D16x ControL Paner User s Manual REMOTE OPERATION AUDIBLE FEEDBACK SUMMARY OF TELEPHONE COMMANDS JJ e The User Code is valid ol Prepare to receive commands 3 beeps e Successful Arming or Disarming 1 Arm Areas e An Auxiliary output has SS been turned ON 2 cia J e Panel is already Armed 1 4 Turn ON or Pulse AUX1 e Invalid code Try again 1 long beep inva eae DAA Turn OFF AUX1 e Remote AUX operation is not enabled 2 2 Turn ON or Pulse AUX2 J e An Auxiliary output has been turned OFF 2 2 Turn OFF AUX2 1 short beep 3 3 B Turn ON or Pulse AUX3 3 3 Turn OFF AUX3 4 4 Turn ON or Pulse AUX4 4 4 Turn OFF AUX4 Finished hang up EXAMPLE ARMING THE PANEL BY TELEPHONE 1 Dial the panel telephone number Listen for one double ring then hang
30. one line integrity monitoring can activate an output if the phone line is disconnected e Dialler Listen in option for installers e Auto Test calls daily weekly or any interval e Pulse or DTMF dialling e True dial tone detection 2 Ness D8x D16x Controt Paner User s Manual The Ness D8x and D16x microcomputer based 8 or 16 zone control panel is the heart of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be wired to the panel or you can use optional wireless detectors Passive Infra Red motion detectors PIRs are used to detect motion of people or animals Pet Aware motion detectors can ignore pets and still detect people Reed Switches are fitted to windows and doors to detect opening Vibration sensors such as the Nessensor can be used to detect glass breakage or forcing of windows or doors Normally a zone is considered Sealed Activation of a detection device will cause the zone to be Unsealed and may cause an alarm Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting A zone with this assignment is called a 24 hour zone Some detection devices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a
31. rming the panel and check the Alarm Memory Siren sounds while the panel is disarmed A 24 hour zone has been alarmed Siren Tamper Box Tamper Panic Button Reset the alarm by disarming the panel and call your installer EXCLUDE light is flashing Cannot arm and the EXCLUDE light is on steady A zone s has been Excluded You are in Exclude mode This is to indicate that one or more zones have been Excluded Press E to exit Exclude mode TAMPER light flashing The 24 hour Tamper input has alarmed Siren tamper or box tamper Call your installer ALARM MEMORY light is flashing There are alarms in memory To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you arm the panel Cannot enter Program Mode The panel is armed Or you may be attempting to enter program mode using one of the user codes Disarm the panel before attempting to enter Program Mode Try again using the Master Code When arm by radio key the Armed light on the keypad does not turn on immediately The panel is waiting 5 seconds for a second press of the ON button to enter Monitor mode This is normal operation when arm ing of Monitor mode by radio key is enabled The keypad is making a continuous slow beep This is the AutoTime warning beep which can be programmed to start from 1 to 99 minutes before an AutoTime event is due to begin
32. s 5 6 8 or 9 when Disarming THE KEYPAD DURESS IS NORMALLY NOT ENABLED TO ENABLE THIS FUNCTION CONSULT YOUR INSTALLER DURESS ALARMS CAN ONLY USED BY SYSTEMS WHICH ARE MONITORED BY A CENTRAL STATION THE DURESS ALARM CAN BE PROGRAMMED TO SOUND THE INTERNAL SIREN RESET OUTPUT THIS OPTION IS OFF BY DEFAULT Ness D8x D16x Controt Paner User s Manual OPERATION Keypad MEDICAL alarm by KEYPAD Press 2 E Sends a Medical Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station The Medical Alarm does not sound the sirens Keypad FIRE alarm by KEYPAD Press 3 Sounds the siren using the Fire Alarm sound If Keypad Fire Alarm has been enabled by your installer And sends a Fire Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station 14 Ness D8x D16x ControL Paner User s Manual OPERATION How to EXCLUDE zones by KEYPAD Press If the ExcLupe SHortcut is enabled or press Giciuse User Cone E The Exclude light will turn on then press Zone No Zone No Enter the zone number s to be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed If ther
33. sometimes does not respond to user codes or the panel arms AN or disarms itself or auxiliary outputs turn on automatically then your panel may have been programmed for AutoTime events Ask your install to check the installer level programming settings and reprogram the system to suit your needs 18 Ness D8x D16x ControL Paner User s Manual OPERATION AUTO TIME OPERATION WARNING PERIOD Optional function must be enabled by your installer When an AutoTime event is about to begin your keypad or keypads will begin a constant slow beep as a warning that the automatic event is about to happen The warning beeps can be programmed to start up to 99 minutes prior to the AutoTime event Press any key on the keypad to stop the beeps during the warning period The beeps will start again for the final minute at a faster rate FINAL MINUTE BEEPS In the last minute prior to the AutoTime event the keypad will beep at a faster rate to warn that the event is about to start TO DELAY THE AUTOTIME EVENT Optional function must be enabled by your installer To delay the AutoTime event enter a valid user code on its own The user code must be assigned to an Area to work This will suspend the warning beeps and the AutoTime event for 1 hour when the warning process will start again Example Your panel is programmed to Auto Arm at 6pm every weekday and the Warning Period is programmed for 5 minutes You are working back late and a
34. ss QD C amp D star keys together or press C User Cone E or press C E If Keypap Panic SHortcut is enabled The keypad PANIC function may have been programmed to be either AUDIBLE to activate the sirens or SILENT to send a PANIC report by dialler if your system is monitored by a Central Station by RADIO KEY Press and hold the PANIC button for at least 4 sec NOTE Your panel may be programmed for DOUBLE PRESS RADIO PANIC To operate press and hold the Panic button until the transmit LED turns on Release the Panic button and immediately press and hold again until the transmit LED turns on a second time This requirement meets regulations in some states of Australia PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button Keypad DURESS alarm by KEYPAD Press 5 6 8 on 9 User Cove Add one these digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler if the system is monitored by a central station The DURESS alarm can be used to send a silent alarm to the central station that you are being forced to disarm the panel against your will That is you are disarming under duress To disarm and send a DURESS alarm prefix your User Code with one of the digit
35. t 5 55pm your keypad begins to beep Since you re not ready to arm the system yet enter your user code without pressing E at the keypad The warning beeps will stop and arming will be delayed by one hour At 6 55pm the warning beeps will start again followed by automatic arming if you don t delay the event again Any AutoTime event can be postponed not just arming You can also delay the automatic turn or off of one of the AUX outputs in the same manner MANUAL OPERATION OF THE AUX OUTPUTS Optional function must be enabled by your installer As well as automatic operation by Auto Time the four auxiliary outputs can also be operated manually by keypad Use the keypad commands below to turn outputs on or off or pulse on To turn ON or PULSE To turn OFF AUX1 OOD OOS AUX2 OJOK D WI E AUX3 VOC OJOK E2 AUX4 VWL JIOR E A Manual operation of outputs works in conjunction with AutoTime schedules if programmed For example if AutoTime has turned an output on as scheduled say a light you can manually turn it off and back on again any time you wish At the scheduled turn OFF time if the output is still on it will be turned off 1 Whether an output Pulses or Turns On depends on the how that output has been programmed by your installer Ness D8x D16x Controt Paner User s Manual 19 PROGRAMMING Programming your Ness D8x or D16x is a simple process using the keypad To enter program mod
36. t Paner User s Manual E PROGRAMMING STEP 1 Master Cove E KEYSTROKES DESCRIPTION Enters User Program Mode Programming USER CODES COMMENT The Program light will turn on 2 Option No E Enter the 3 digit option number for the user code being pro grammed The existing user code if any will be displayed by the keypad one digit at a time 3 New Cope E New Cove E Enter the new user code twice for verification Keypad codes can be 3 6 digits long User codes must NOT start with zero The new user code will be displayed by the keypad one digit at a time 4 To exit User Program Mode The Program light will turn off A keypad code can be deleted by pressing at STEP 3 above Q A keypad code only needs to be deleted if you re not replacing it with a new code EXAMPLES The panel must be in program mode e To program User Code 1 to be 1234 Press P201E 1234 E 1234 E e To delete User Code 2 without programming a new code P202E MEMORY E USER CODE PROGRAMMING RULES Up to 56 Keypad Codes can be used at up to 3 wired keypads for controlling all panel functions including Arming Disarming Home Mode Panic memory recall and much more Keypad Codes can be 3 to 6 digits in length and can be individually programmed and deleted User Code 1 is also the Master Code which is used to enter Client Program mode All 56 User
37. u for example stay at a relative s house overnight and you want the panel to call you there in the event of an alarm When you delete the Follow Me Telephone Number alarm calls will again be made to the Primary and secondary telephone numbers If your Ness panel is monitored by a Central Station the Follow Me number is ignored For all other programming changes talk to your installer 20 Ness D8x D16x ControL Paner User s Manual PROGRAMMING OPTIONS TABLE USER CODE OPTION NO KEYPAD PIN USER CODE OPTION NO KEYPAD PIN 1 Master Code P201E 123 29 P229E 2 P202E 30 P230E 3 P203E 31 P231E 4 P204E 32 P232E 5 P205E 33 P233E 6 P206E 34 P234E 7 P207E 35 P235E 8 P208E 36 P236E 9 P209E 37 P237E 10 P210E 38 P238E 11 P211E 39 P239E 12 P212E 40 P240E 13 P213E 41 P241E 14 P214E 42 P242E 15 P215E 43 P243E 16 P216E 44 P244E 17 P217E 45 P245E 18 P218E 46 P246E 19 P219E 47 P247E 20 P220E 48 P248E 21 P221E 49 P249E 22 P222E 50 P250E 23 P223E 51 P251E 24 P224E 52 P252E 25 P225E 53 P253E 26 P226E 54 P254E 27 P227E 55 P255E 28 P228E 56 P256E OPTION NO DESCRIPTION DEFAULT COMMENT P26E Entry Delay Time 1 20 20 sec P27E Entry Delay Time 2 6 60 sec This option works in multiples of 10 6 60 sec P28E Exit Delay Time 60 60 sec POOE Follow Me Phone No blank Ness D8x D16x Contro
38. y RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery RK1 Radio Key Pendant RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery Top RR2 Mini Radio Reed Switch Bottom RR3 Micro Radio Reed Switch WIRELESS PRODUCTS NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the control panel lt oog oog ooe oog Also operates Home Mode and provides a Panic alarm The Ness Radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires F T PET RiU MADE AUSTRALIA 7 oe R12 Radio PIR ee R15 Radio PIR RADIO MOTION DETECTORS Ness R15 Radio PIR and Ness R12 Radio PIR for wireless motion detection Can be used in combination with Ness hardwired detectors in areas where it is not possible to install wires Includes long life lithium battery The Ness R15PET Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside RAD
39. y Day Zone feature which allows easy and flexible Day Zone selection and operation Temporary Day Zones operate in addition to Permanent Day Zones which are usually setup by the installer While remaining in normal operating mode the user can add and remove Temporary Day Zones As an extra feature the user can easily enable or disable Day Mode which includes both Temporary and Permanent Day Zones Day Zones can be programmed by your installer to beep the keypad or briefly sound the siren s or flash the strobe light or to sound an optional buzzer Although the keypad beeper provides sufficient warning in most situations TYPICAL APPLICATIONS Day Zones are useful for a variety of applications such as a shop door beeper triggered by a reed switch on the door For example in a shop you could enable Day Mode to alert you when a customer enters the front door You can also enable additional Temporary Day Zones to monitor switches on for example the rear door or the fridge doors TEMPORARY DAY ZONES COMMANDS Accessed from normal operating mode Enter Selection Mode Press P followed by E when in operating mode to enter Temporary Day Zone selection mode Zone Selection Zone No To select or deselect zones to be Temporary Day Zones The selected zones are indicated by the corresponding zone number Permanent Day Zones installer option P53E are not displayed in selection mode P
40. your installer can program the external siren to chirp 3 times when disarming by ACCESS CARD or FOB Bs Present a Card or Fob once if the installer has enabled disarming by access card ARM ONLY CODES User codes can optionally be programmed to be Arm Only codes An Arm Only code can Arm the system but it cannot Disarm See page 22 for User Codes programming However if an Arm Only code is assigned to a radio key the radio key OFF button will arm and disarm AUTO RE ARM Your panel may optionally be programmed for Auto Re Arm to help prevent accidental disarming Auto Re Arm checks that you have entered the premises after disarming If all zones remain sealed for a period as set by the entry delay time then the panel will re arm This is most useful when used with radio keys where the OFF button might be accidentally pressed after you have armed and are leaving the premises If Entry Beeps are enabled 2 In the event of an alarm the strobe light will flash for 72 hours or until the panel is reset Ness D8x D16x ControL Paner User s Manual EA OPERATION to arm HOME Mode by KEYPAD Press If the Home Monitor SHortcuT is enabled by RADIO KEY Home Monitor arming by radio key must be enabled by your installer or press User Cove E Home mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored