CD-1 User`s Manual - BLAUBERG ventilatoren
Contents
1. BLAUBERG Ventilatoren www blaubergventilatoren de CD 1 Wall mounted CO sensor with 1 analog output amp 1 on off output User s Manual E SPECIFICATIONS Parameters Value 24VAC 50 60Hz 10 24VDC max 1 6 W lt 2 minutes o O Response time lt 2 minutes 2 hours first time 2 minutes operation Analogue output 0 10VDC default 4 20mA selectable by jumpers 1X2A switch load On Off output Four set points selectable by jumpers 1st green indicator lights when CO concentration is below 600 ppm Warm up time for each turning on 1st and 2nd green indicators light when CO concentration is 600 800 ppm 1st yellow indicator lights when CO concentration is 800 1200 ppm 1st and 2nd yellow indicators light when CO concentration is 1200 1400 ppm 1st red indicator lights when CO concentration is 1400 1600 ppm 1st and 2nd red indicators light when CO concentration is above 1600 ppm Operation conditions 0 50 C 0 95 RH non condensing Storage regulations 0 50 C Net weight Dimensions 120g 100mm x 80mm x 30mm Mounting standard 65mm x 65mm wire box or hang on a nail Standard Approval 6 LED lights E MOUNTING AND WIRE CONNECTION e Notice the supply power voltage of the Fig 1 Dimensions sensor 24VAC VDC Do not install the sensor on voltages higher than marked on the sensor BLAUBERG e Follows the steps in fig 2 to remove the cover e Mount th
2. e sensor on the place where you lt want to detect CO level Do not mount it Socket for a near diffuser or any steam source in direct oe 12 24VAC VDC sunlight Pb rss power adapter e Mount the wall plate first there are two Lerna dimensions available see fig 1 Place the sensor against the wall at selected location p 1e O O O O an make sure wires pass through the notch on Touch button for switching on the wall plate off auto operation modes of e Connect wires to terminal strips see fig 4 the fan Make sure wiring connection is correct and ee secure e Follows the steps in fig 3 to close the cover Fig 3 CD 1_EN indd 1 26 10 2015 16 27 48 Fig 4 Wiring Connection Terminal E romer zancos L1 ARR E i a Power ground 24VAC 24VDC co 0 10VDC default 2 10VDC 0 20mA Analog output 4_20mA 0 2 000 ppm CO ey D 24VAC aan Relavoutput lt 240VAC 30VDC 2A switching Transformer y p current resistance load Function Electrical Data Power E SELECT OUTPUT e Power off first and remove the face cover you ll see a Jumper 51 52 ere PTAC ours set of short circuit block jumpers in the middle of the right side of PCB board From left to right it s J1 J5 Lower two pins blocked 0 10VDC default and S1 S2 Choose the type of analogue output or Upper two pins blocked CO leve
3. l to control the relay following instructions Lower two pins blocked gt 10VDC shown in table shown in table below J2 amp J3 are just i ins blocked for manufacture test Please don t change it Pee awe Jumper J4 J5 CO level The relay turns on turns off IMPORTANT INSTRUCTIONS CD 1_EN indd 2 1 Don t shake or hit the sensor too much during shipment or mounting to protect the internal infrared CO sensor from any damage and excursion of infrared receiver 2 When a First use CO sensor or b Reuse CO sensor after a long time unused or c CO measurement is proved to be incorrect by comparing with the measurement of other CO sensors or put the sensor outdoors and its measurement is away from the range of 350ppm 450ppm which is the normal ambient CO concentration then let the self calibration system work as follows Keep the CO sensor energized continuously for at least 2 days to let CO sensor s self calibration system operate properly After more than 2 days calibration if the measurement indicated by the analog output of the CO sensor still exceeds over the accuracy you need to let it self calibrated for a longer time Here s a typical 14 day calibration solution During a 14 day period place the CO sensor twice outdoors or in unoccupied places where CO level is around 400 ppm Each time let it be there for more than 4 hours and then check the CO measurement via analogue output If the CO mea
4. surement is in its accuracy limit it indicates the measurement is correct Notice a Using of cellular telephones or radio transceivers about 60 cm away from the sensor during calibration process could cause sensor interference calibration errors and affect sensor accuracy Please refrain from using these devices during calibration of the sensor b When checking the analog output please avoid breathing out directly to the CO sensor It s recommended to connect the output terminals with the extending wires with length of more than 1 meter When the CO sensor indications become stable after more than 10 minutes turning on check the analog output through the extending wires to avoid influence of breathing process on CO concentration 2 CD 1V1 2 EN 26 10 2015 16 27 50
Download Pdf Manuals
Related Search
Related Contents
Philips MCM118D Micro Hi-Fi System 9チャンネルデジタルレコーダ EDR901 取扱説明書 Manual Samsung FX2490HD Наръчник за потребителя 500 Serie 1 page, p. 34 Gas Chromatograph Varian 3700 Series User Manual Copyright © All rights reserved.
Failed to retrieve file