UPS Wizard User`s Manual Page : 1 of 19 1. The

image

Contents

1. 8A from battery when no load is connected The following fig shows the calculation result Backup Time Caleulation Efficiency of Batter Batter backup mode Full load i r he a Eh E e F200 ho y r alculate stand by Battery Type current Normal m cate Celeste Close 0 8 A f High Density Energy capacity 1200 WV for 14 3min Dump Result Full load current 30 2 A mep p e p p ee Watt under OO 360 1440 2400 304 0 S60 FOU 1020 0 load level Depth of roe bd 55 4 40 6 424 ae ae discharging Backup ahr Thr Thr 39 6min 22 0min 13 7min Soimin 6 1min time 35min 45min Emin Page 14 of 19 UPS Wizard User s Manual 12 11 New Battery support for LCD version at advanced mode w This function is designed for data input and auto calculation of the backup time Mew Battery after the UPS is replaced with a new battery set For example A 2 2KVA 1350W UPS uses 4 REW45 12 YUASA batteries high density type for battery replacement The UPS inverter efficiency is 88 and it takes 0 6A from battery when no load is connected the charging current is 2 4A Input the data for calculating the new set up and select Write New Setting to UPS Setting to update the UPS backup time data New battery X Efficiency of Charging Batter Batter backup mode Full load current 7 0 Ah E Hy 96 0 of 1350 WM 2 4 ap stand by Battery Type 1 al Normal Energy capacity 1350 W for 13 1min New
2. is normal ines pace The fig shows AC input has failed ae The fig shows battery voltage is normal Battery Lo wae The fig shows battery voltage is too low LEU display Ver 10 LEDO display Ver The fig shows the display type is installed and the version of it Cae UPS Manufacturer UPS Model x series UPS Version 5 75004505 The fig shows the manufacturer of the UPS model and version 2005 06 13 15 42 35 Find Supported UPS at COM te 2005 06 13 15 43 42 Mot supported UPS if you are sure this UPS support UPS wizard for sett 2005 06 13 15 52 47 Error opening serial port 2005 06 73 15 53 12 Can not find UFS i The fig shows the communication message COM xx series V5 15C4505 115 gt 1O5 25 107 60 0Hz 29 00 The fig shows the feed back data from UPS Page 3 of 19 UPS Wizard User s Manual 12 Function icons for setting UPS 12 1 c Select the icon to input unlock code The advanced functions are designed for a service engineer you must input the unlock code to enable the advanced functions nloc Advance Mode Pas Code Please follow the key No each for individual agent to input correct pass code ERROR E x The fig shows pass code incorrect a After input correct pass code The unlock fig will show All the advanced functions gray color icons will be activated 12 2 Analog to Digital converter ADC adjustment a The function is used to adjust th
3. O NOT change the data Year 2005 w Month May Input the new battery date code then press O K Page 7 of 19 UPS Wizard User s Manual 12 5 Battery related level set up y Battery Related Battery mode level adjust O P voltage at battery mode 13 3 The seting will come into effect when battery is fully charged The battery related levels include the O P voltage at battery mode low battery shutdown level and averaged floating charge voltage OP voltage at battery mode The actual O P voltage at battery model is the same as rated value 100 110 115 120 or 200 220 230 240Vac Before adjustment Page 8 of 19 UPS Wizard User s Manual OP voltage at battery mode After adjustment Low batter shutdown level for each 124 battery The standard low battery shutdown level is 9 6V it is allowed to adjust between 9 6V 10 5V when connecting the UPS with big external battery for long backup application Average charging voltage for each 12 battery 1a 13 5 1345 The setting will come into effect when battery is fully charged When battery is not fully charged the average charging voltage is 14V for each battery to make sure the battery being fully charged the charging voltage 14V is not adjustable When battery is fully charged the floating charging voltage will be reduced for extending the battery lifetime Normally 13 5V for each battery is a suitable leve
4. Setting 649 0 8775 1147 5 load level 544 497 455 discharging 1 hr Thr 40 2min 23 4min 14 4min 9 8min 6 9rnin Emin 48min min Write New Setting to UPS Seting UFS Setting 108 0 1620 2700 4320 648 0 8775 11475 load level Depth of discharging Backup time The LCD version of UPS provides the estimation of backup time EBT with accuracy Every time Prb ho 6 1 6 53 7 qi 41 2 36 1 ahr 1 hr 1hr 37 1 min 2 0rin 12 4min o tmin 5 5rnin demin 45min Gmin when the UPS is running in the battery mode the CPU of LCD display will adjust the backup time record if low battery alarm occurs The record provides the EBT system to calculate the backup time when a blackout happens next time Once the battery is replaced the engineer will need to re input the related data of the new battery for a new backup time to keep the EBT system in the best accuracy Page 15 of 19 UPS Wizard User s Manual 12 12 vy i Battery Performance support for LCD version at advanced mode Battery Feormance The function is designed to adjust the database of backup time When the battery performance decays after years of using the EBT system may not display the correct backup time To check the accuracy of EBT system please select Testing UPS to low battery from the monitoring software for example the UPSilon2000 When testing a UPS the EBT will count down according to the load level When UPS emits low batte
5. UPS Wizard User s Manual 1 The communication cable M2502 This is a special designed cable for the communication of UPS with your PC only connecting with the correct cable the PC can detect the UPS 2 The main window of the UPS Wizard is shown below AA UPS Wizard File Font About a a UPS Type Line Interactive Wavetorm gt Pure Sine Wave Froduct Date Code 200505 Battery Date Code 200505 UPS type and Data Code AID Input Output Level Adjustment Input Voltage Input Frequency Output Voltage Output Load E E M A UFS Rating ALC Voltage Rating 110 0 Wac alta acer Battery Voltage Rating 24 0 Yde Curent Rating 10 004 basic information Frequency Rating 60 0 Hz eee Communicating with PE Utility Power Normal Battery Normal Ca Te 5 E Battery Date LED display Wer version UPS Manufacturer OER UPS Model xx series oh SGN mi UPS Version Yerl O0_ES 2005 06 16 17 01 08 Not supported UFS if you are sure this UPS support UPS Wizard for sett 2005 06 16 17 01 17 Not supported UPS if you are sure this UPS support UPS Wizard for sett Low Backup 2005 06 16 17 01 24 Error opening serial port o o Level 2005 06 16 17 01 56 Find Supported UPS at COM Communication message a H Fs Verl OO_Es 112 gt 112 27 707 60 0Hz 28 00 Feed back message fram UPS Function icons for setting URS Page 1 of 19 UPS Wizard User s Manual 3 Select the com port for UPS or select Aut
6. a under backup mode or test mode when low battery alarm The data is used for reference of EBT system under next blackout The following set up will not run if EBT record is in off mode Recording of the backup time under blackout Off ft 5 masimum When this function is off EBT will record and adjust the backup time data only at testing mode If an engineer can run Testing UPS to low battery from the monitoring software on schedule This function can set for off to prevent uncontrolled self adjustment in backup time database Page 18 of 19 UPS Wizard User s Manual Recording of the ee time under Test Mode Load Level 2 10 1521 152 252 252 408 4 e 59 7004 g0 00 Corrected value att 52 E a a ma imum There are 8 groups of database for different load levels The adjustment method of the backup time database can be changed separately according to the load condition Normally choose exact value as tested is suggested When using the long life battery the engineer may expect that the database will not change too much each time when engineer run Testing UPS to low battery This function can provide a way to control self adjustment in 5 to prevent wrong adjustment when UPS is not tested with fully charged battery Please select Corrected value at 5 maximum according to the load level that UPS is loaded generally Page 19 of 19
7. as spikes notches dips swells and the distortions caused by operation with generators as well When power quality is poor the UPS may frequently transfer to battery mode operation if a load can operate normally under poor power condition as mentioned above disable the High sensitivity may conserve the battery energy and capacity Page 11 of 19 UPS Wizard User s Manual 12 9 Model Set up support for advanced mode only The set up of model will change the operation mode of UPS the calculation of RS232 data and LCD display mode The engineer must change the set up of model very carefully If an engineer needs more detailed information of the model set up please contact us Page 12 of 19 UPS Wizard User s Manual 12 10 Backup time calculation If you are not sure how much backup time you can get with a selected battery this Backup program will answer you Time Cal Backup Time Caleulation Efficiency of Batter Batter backup mode Full load Calcul ho ty bs tw alculate stand by Battery Type current f Normal m unio Calpe Close A C High Density Energy capacity WV for Bump Result Full load current A wakt under load level Depth of discharging Backup time Baner The capacity of the UPS battery 7Ah 12Ah 25Ah or 38Ah Ah If you use two 7Ah batteries in parallel connection please input 14Ah The total battery voltage with series connection Batter i V
8. e ADC ratio for AC input voltage AC output AI voltage and battery voltage Adjustment D E A d i uat The ADC provides 7 adjustment The result will be stored inside the flash memory of UPS so that the set up will not disappear when UPS is turned off Page 4 of 19 UPS Wizard User s Manual When AC input voltage is 111V but UPS shows 115V by reducing 3 of the sensed AC input level will correct the ADC of AC input The result is shown below Page 5 of 19 UPS Wizard User s Manual When AC output voltage is 111V but UPS display 115V by reducing 3 of the sensed AC output level will correct the ADC of AC output The result is shown below When battery voltage is 23 4V but UPS display 22 9V by increasing 2 of the sensed battery voltage level will correct the ADC of battery voltage The result is shown below Page 6 of 19 UPS Wizard User s Manual 12 3 12 4 GO Company name and model name set up Support for advanced mode only H Quick Input Company Mame Model Name X Cancel Input the Company name and model name then press O K AN Battery Date code adjustment support for advanced mode only Battery Date Code New Battery Input new date only after replacing by NEW BATTERY otherwise DO NOT change the data Year 2005 Month May M Cancel New Battery Input new date only after replacing by NEW BATTERY otherwise D
9. from By OFF mode when connect utility power to the UPS While if disable the function Setting UPS will stay in the OFF mode but keep charging When the AC rating is changed the O P voltage will be changed not only at the battery mode but also at the AC mode Rating selection Iw Auto power OM by AC IF AC Rating f 1007 2004 f 110V 7 220 C 11577 230 C 120 240y f 60Hz C 50Hz W Auto Buzzer ON W Enable safe power ON Iw High Sensitivity for Blackout x Cancel When the frequency set up is changed the O P frequency will not change at once only after a complete shutdown and to have a DC start on the UPS then the O P frequency will apply the set frequency During the battery mode by pushing the button for entering silence mode is a friendly design but when a blackout happens next time the UPS won t emit blackout beeping To have the beeping whenever a blackout happens please enable Auto Buzzer ON Safe power ON is a function that delays Auto power ON function When this function is enabled the Auto power ON will be triggered only after the battery is charged to 12 8V up for each 12V battery Without this function any short time recovery of utility power will trigger the UPS to turn ON but if battery is empty UPS cannot protect your equipment at all When the High sensitivity for Blackout is enabled the UPS provides very fast response in detecting the line voltage distortions such
10. l Page 9 of 19 UPS Wizard User s Manual 12 6 VW The reduction of low AC transfer level is a very useful function when the utility La eack power is poor Level Reduction for low AC transfer level The lower the low AC transfer level the lower the chance to discharge the battery energy However the lower transfer level will decrease the O P voltage level when utility power is normal but voltage is very low Only those equipments applicable with wide I P voltage range are suitable for applying this adjustment 12 7 When UPS reaches the full load level the UPS will emit overload alarm and shutdown at overload shutdown level The higher the overload the shorter the Load Level battery backup time Control Load level adjust Over load shutdown level Green mode level EEE Oe OFF TA The Green mode function is to have UPS shut off automatically when load level is under the preset level in battery mode When a blackout happens some equipment provides auto shutdown function but some of them may not provide signal to shut down UPS because more than one equipment is connected to the UPS and the timing is hard to control To enable the green mode function will be a perfect solution to save the battery energy or provide shutdown reset signal when utility power is back Page 10 of 19 UPS Wizard User s Manual 12 8 To enable the function of Auto power ON the UPS will turn on automatically
11. monitoring software for example the UPSilon2000 User can check the set up from the LCD display when UPS receives a command from PC side User can t set nor change the set up at all without a PC To enable the function will provide a new way to change or set the time for turning on or off the UPS EBT systern C Off On default The LCD version of UPS will provide the estimation of backup time EBT with accuracy if the database is correct Engineer can disable this function if the database is wrong or when users do not need this function The following set up will not run if EBT system is in off mode Turn off EBT systern at low batter alarm Yes f No default Normally the EBT system is possible to show 1 or more minutes when UPS shutdown by battery low To adjust the database from the bar of Adjust the battery performance for backup time after decay in battery performance as shown in 12 12 may avoid this situation Another simple way is to turn off EBT system at low battery alarm thus will force the UPS to count down the backup time from 1 0 minute However the UPS may still have one more minute of backup time when the countdown is 0 0 minute EBT Correction by Batten Woltage C Off On default When this function is on EBT will correct the count down in reference of battery voltage Backup time recording C Off On default EBT system will record and adjust the backup time dat
12. o Detect if you do not know which com port is connecting to the UPS MAUPS Wizard File Port About Auto Detect COM1 COM2 COM3 COM4 When the com port is occupied by a monitoring software for example the UPSilon the auto detecting will fail Please exit UPSilon first before executing UPS Wizard Open UF silon About Exit Rupsnon En When the communication is O K it shows the following information UPS Type Line Interactive Wavetorm gt Pure Sine Wave Product Date Code 90505 Batter Date Code 200505 UPS Type On Line Line Interactive or OFF Line Waveform Pure Sine Wave or Step Wave Product Date Code UPS manufacturing date Battery Date Code Battery replacement or installation date Input Qutout Level Input Voltage Input Frequency Output Voltage Output Load MB va 60 He 1065 v 0 amp z Input Voltage 115Vac Input Frequency 60Hz Output Voltage 105Vac Output Load 0 Page 2 of 19 UPS Wizard User s Manual T 9 10 11 WPS Rating AC Voltage Rating 110 0 Vac Batten Voltage Rating 24 0 Wde Curent Rating 10 004 Frequency Rating 60 0 Hz AC Voltage Rating 100 110 115 120Vac or 200 220 230 240Vac Battery Voltage Rating 12 24 36 48 60 72 Current Rating UPS maximum O P current rating Frequency Rating 50 60Hz with The fig shows communication is good i T es The fig shows the communication is lost peyote The fig shows AC input
13. ry alarm check LCD if it shows 1 or 2minutes for the backup time of the battery it is very normal basically if total backup time is 20minutes deviation for 1 or 2minutes is acceptable its suggested to make some adjustment if over 15 Battery Performance x The battery performance records compared with new battery Record Record Records Record4 Records Records Record Records 746 2i 77 6 Hs 88 1 2i 96 4 2 wi vo 2 88 6 vo Adjust the battery performance for backup time after decay There are 8 kinds of battery performance records for the load level from 3 to 85 Each time when the UPS is running in the battery mode and discharged to low battery alarm the backup time will be recorded into the battery performance data for the reference of adjusting the battery performance Generally we select the lower 3 or 4 values in average for the new set up of battery performance For example A UPS has 5 records of battery performance from 74 to 96 We use the averaged value from 74 to 88 for calculation of decay Input 81 for calculating the new backup time and select Write New Setting to UPS Setting to update the UPS backup time data Page 16 of 19 UPS Wizard User s Manual 12 13 Battery Performance x The battery performance records compared with new battery Record Record Records Record4 RecordS Records Record Records 746 2 77 6 2 88 1 2i 96 4 2 K 7 2 88 6 vo Adjust the battery per
14. tormance for backup time ater decay geed eae ey New battery ae one a E 7 e jar m watt under iga 108 0 1620 27 00 4320 b640 rr 1147 5 load level 3hr thr 5D 0min 27 3rnin 14 6min 81min 49min 3 0min time 12min 23min Write Mew Setting to UPS Setting UPS setting Watt under 40 5 106 0 1620 Le load level Backup ahr Thr Thr 3 7 imin 2 Ormin 12 4min o lmin S 2min Lime d min 45min Grin jeng LCD Display support for LCD version at advanced mode This function is designed for the set up of LCD display and EBT system L D Display setting LCD operation mode Communication beeping Enable Disable default This function is enabled only when the engineer needs to check the communication between the two CPUs main amp display Please disable it for user If enable the beeping the LCD will emit a short time beep whenever the LCD receives a command for reading the flash memory Display mode LCD slave LED master f LCD master only This function is designed to set up the display mode When an LED display UPS needs to install an external LCD display for remote control the control bus is in parallel connection To separate the control signal the LCD display must be set in slave mode Page 17 of 19 UPS Wizard User s Manual Setting time to tum OneUt UPS Enable Disable default The UPS supports remote control for turn on and turn off schedule from the
15. v Efficiency of The transfer efficiency of UPS inverter from battery to the UPS output backup mode Generally 85 is a typical value for UPS inverter Ho ail REG The full load level of a UPS change of each scale is 25W 2 Sw Stand by Under no load condition the basic current that a UPS requires to maintain current the output voltage when the UPS is turned on at battery mode Page 13 of 19 UPS Wizard User s Manual The high density type provides higher depth of discharging as compared with a normal type so it provides longer backup time when load is at high level Battery Type i Normal C High Density For example The NP7 12 YUASA is a normal type battery and REW45 12 YUASA is a high density one Both are the same capacity 7Ah 12V but different backup time when using in UPS at high load level Select Auto Calculate to calculate the backup time when the parameters are W Auto Calculate changed It shows the backup time when battery energy is 100 Energy capacity vi for j a discharged at full load level The full load current is the battery current when UPS is full Full load current A loaded It helps engineer to decide what size of DC cable should be used Fill in the information of the UPS then press calculate to calculate the backup time For example A 2KVA model 1200W UPS uses 4 pcs of NP7 12 YUASA battery The UPS inverter efficiency is 85 and it takes 0