Home

Classic Manual LOCKED - Single

image

Contents

1. The sound processor 15 not waterproof Never wear it in the bath or shower If it gets wet by accident open the battery door immediately and take the battery out Leave the battery door open until it is dry Do not expose the sound processor to extreme heat etc If you are to undergo an MRI Magnetic Resonance Imaging procedure the sound processor should be removed beforehand The fixture and the abutment remain in place Your sound processor should be protected from dust and dirt so always keep it in its box when not bemg worn English Troubleshooting If redness and or soreness occurs clean the skin around the abutment and apply a mild antibiotic cream omtment provided by the clinic If redness and or soreness persists you should contact your clinic If the sound processor makes a crackling or buzzing sound try changing the battery If the sound processor does not work is silent change the battery and check that the position of the volume control the tone switch is correct If the problems persist you should contact your hearing aid centre Baha Classic 300 7 English Service and repairs If there 15 a fault with your Baha sound processor contact your ear clinic or hearing aid centre and they will help you to get 1t serviced Telephone number of hearing aid centre Contact person Telephone number of ear clinic Contact person Manufacturer s Warranty Entific Medical Sy
2. soap and water Contact your doctor if you have persistent problems such as soreness formation of pus or inflammation around the abutment For children who have been fitted with a Baha it is extremely important that the parent or caregiver of the child inspect and aid in the proper cleaning and maintenance as detailed in the information above Telephones Io use a telephone with your sound processor hold the receiver in the normal way but close to the microphone inlet of the sound processor instead of close to your ear It is important that you do not touch the sound processor since this may cause feedback whistling Baha Classic 300 Abutment cover An abutment cover is included in or is not in place Simply press the cover on to the abutment the kit It can be placed over the abutment when the sound process Attachment of the safety line When you engage in physical k S activities we advise you to attach a safety line to your sound processor so that it is not lost if it disconnects 8 The clip can then be fastened to your shirt or jacket collar Share the Experience The test rod provided can be selves Snap the sound processor on to the test rod and hold the rod against the skull bone behind the ear take used by others to listen to your Baha sound processor them care not to allow the sound processor itself to touch any thing as this may cause feedback General advice
3. Baha Classic 300 users manual Dansk Deutsch English lt Espa ol Francais lt EAAnVIKd Italiano e Nederlands Portugu s lt Suomi s Svenska 0413 baha DANSK TT 3 a l u E IEE E EE sapan pasas TE FE 9 EG a E E 15 Espa ol EAA eee 21 Fran aiS 27 F IU u uuu 2 Dam cannes E a uyasapa 33 l la uuu R E 39 Nederlands 45 Portugu s 51 SUOMI 2 S S n puya eee 57 SV IK eda EEE E EEE SIET T upi teens 63 Instructions for use in the USA 71 Users Manual for Baha Classic 300 Baha Classic 300 is a bone anchored sound processor which allows you to hear via direct bone conduction Direct bone conduction means that sound is transmitted directly through the skull bone via a titanium fixture bypassing the middle ear The sound processor is held in place by an abutment which is directly connected to the fixture The titanium fixture is firmly anchored in the bone by the process of osseointegration Please read this manual carefully to learn about your sound processor Be sure to discuss any questions or con cerns that you may have regarding hearing or use of this system with your hearing health care professional Illustration of the sound processor This list refers to the illustration located on the inside of the front page 1
4. Volume control on off 6 Microphone 2 Tone switch 7 Plastic snap 3 Electrical input 8 Attachment for safety line 4 Battery compartment 9 Serial number 5 Battery cover English How to connect and disconnect the sound processor A plastic snap is mounted to the sound processor It is designed to snap into the abutment and hold the sound processor securely in place Connecting Hold the sound processor so that the plastic snap is accessible and move any hair away from the abutment Bend and push the unit in carefully and it will attach to the abutment Disconnecting Bending the sound processor slightly in any direction will re lease it from the abutment Note Do not push the sound processor straight in and do not pull it straight out Baha Classic 300 3 English Volume control If you turn the volume control upwards the volume increases and if you turn it downwards it will decrease If you want to switch off the sound processor turn the volume control all the way down until it clicks off Tone Switch The tone switch has three positions Position N This is the normal position It 15 set to enable you to hear normal conversation as clearly as possible Position L This middle position has a softer sound with less treble It is intended for use in noisy environments such as in traf fic workplaces or where there is a considerable amount of interference noise from cutlery dish
5. es etc You may sometimes need to increase the volume Position E In the bottom position the internal microphone of the Baha Classic 300 sound processor is disconnected Use this position if you want to connect external equipment such as a telecoil unit and want to listen through the telecoil only Electrical input The sound processor has a three pin electrical input designed for connecting external equipment Note that the red marking on the plug must match up with the cor responding marking on the sound processor Set the position of the tone switch on N or L if you want to listen both from the internal microphone and the external equipment Set the switch on E if you want to listen through the external equipment only Accessories There are several accessories available for your sound processor Please contact your hearing aid centre for more information Safety instructions when connecting external equipment Only connection cables supplied by Entific Medical Sys tems should be used Non standard connecting cables can cause damage to the sound processor and injury to the patient Entific Medical Systems is not liable for any damage arising as a result of using incorrect equipment or incor rect use Warning It is extremely dangerous and po A tentially fatal to connect any equipment that is plugged into a 110 and or 220 V power supply without using the audio adapter Maintenance The sound pr
6. ocessor can be worn during waking hours apart from when you take a shower swim or engage in physical activity that might damage it Ensure that the sound processor is switched off when not in use to save the battery At night and in a clean environment the box and battery compartment may be left open to allow any trapped moisture to evaporate Battery replacement Mercury or zinc air batteries type 675 should be used Please note that these batteries are not rechargeable Open the battery compartment by sliding the cover downwards Turn the sound processor over and the battery will fall out Shake the device gently if the battery has stuck Place the new battery with the mark facing outwards Press the battery down with your thumb and close the cover If you can not slide the cover back easily the battery might be incorrectly inserted Please check the mark Warning The Baha sound processor con A tains small parts that may be a risk for small children Batteries can be harmful if swallowed Be sure to al ways keep vour batteries out of reach of small children or people of diminished mental capacity In the event a battery is accidentally swallowed seek prompt medical attention at the nearest emer gency centre Baha Classic 300 English Cleaning You must clean the skin around the abutment daily Skin debris may build up around the abutment and it is impor tant that you remove it Use a soft cleaning brush
7. stems will repair or replace your Baha sound processor without charge during the warranty time if defective materials or workmanship cause the system to be inoperable The warranty does not cover loss or damage to the sound processor Batteries and accessories are not covered under the manufacturer s warranty Please consult your hearing healthcare professional for exact duration further terms and extent of this warranty Your opinion is important If you have any suggestions for product improvements please write to the address on the back of this manual Baha Classic 300 Instructions for use in the USA Instructions for use in the USA Caution Federal law USA restricts this device to sale by or on the order of a medical practitioner A prospective user of the Baha system must always have a medical evaluation by a licensed physician preferably an ear specialist and have an implant placed in the skull bone before the sound processor can be dispensed A sound processor will not restore normal hearing and the use of it is only a part of hearing rehabilitation Infrequent use of a sound processor does not permit a user to attain full benefit from it Warning Batteries can be harmful if swallowed Be sure to always keep your batteries out of reach of small children or people of diminished mental capacity In the event a battery is A accidentally swallowed seek prompt medical attention at the nearest emergency centre or call
8. the national Button Battery Hotline collect at 202 625 3333 Baha Classic 300 71 Entific Medical Systems PO Box 16024 SE 412 21 Goteborg Sweden Tel 46 31 733 37 00 Fax 46 31 335 88 60 E Mail info entific com Visit www entific com Baha is a registered trademark of Entific Medical Systems Cochlear and the elliptical logo are trademarks of Cochlear Limited Entific Medical Systems is a Cochlear Group Company Hear now And always Cochlear 17496 Geson SkandiaTryckeriet Printed in Sweden E80567 A 05 06