Home

KP-S1 User Manual

image

Contents

1. use only shielded interface cables when connecting to computer or peripheral devices Incorrect PIN code Request for Home arm when under Away arm mode Request for Force Arm Fault LED The Fault LED light up whenever faults are detected in the alarm system FE CE Q KS BLAUPUNKT
2. according to Control Panel mode 10 C to 40 C relative humidity 85 non condensing Red LED On Away Arm mode Radio Red LED Flash 433 MHz Ble LED on Specification Dual Key Alarm Function Dual Key Alarm function will activate alarm when both keys are pressed at the same time To use the functions please enable them under Test Mode Default are disabled TF Pe a7 g Emergency Alarm LED Indicators Active LED The Active LED light up whenever any key is pressed FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance Keypad in Standby Mode Blue LED On Keypad in Normal Operation Blue LED Flash Keypad in Normal Operation and under Low Battery Orange LED On Keypad in Test Mode Orange LED Flash Keypad in Test Mode and under Low Battery Status LED The Status LED light up during operation or when the Status key is pressed to inquire Control Panel status Red LED On Away Arm mode Red LED Flash Blue LED On Blue LED Flash No reply from Control Panel may void the user s authority to operate this equipment Example
3. to Arm with Use PIN code gt 9 under Test Mode Away Arm Enter a Control Panel User PIN Code Arm Key Home Arm Enter a Control Panel User PIN Code Home Key Disarm Enter a Control Panel User PIN Code Disarm Key If Remote Keypad is set to Arm without Use PIN code gt 8 under Test Mode When the Remote Keypad is on low battery follow the procedure below to change the batteries 1 Open the back cover Remove the old batteries Press any key several times to fully discharge Insert the new batteries observing correct polarity mo ge Ty Replace the back cover Factory Reset If you forget your Keypad PIN code or the Remote Keypad has any problem you can reset the Remote Keypad to factory default Press Arm Key Press Home Key 1 Open the back cover and iui the battery Disarm Enter a Control Panel User PIN Code 2 Press and hold 3 key and insert battery Disarm Key 3 The Remote Keypad will sound 3 short beeps If Remote Keypad is set to Arm with Keypad PIN code x 4 Release 3 key the reset process is now complete 0 under Test Mode Enter Keypad PIN Code Arm Key Enter Keypad PIN Code Home Key Enter Keypad PIN Code Disarm Key Checking Control Panel Status buj Environmental Condition Press the Status key to inquire Control Panel status the Status o a LED will light up
4. Wireless Remote Keypad KP S1 7 2 3 4 8 5 9 6 10 7 Parts Description Active LED Blue Orange Status LED Blue Red Fault LED Orange Away Arm Key Home Arm Switch Status Key Disarm Key NO 8 FP WD ND 8 Panic Alarm Press both 1 and 3 key to trigger Panic alarm 9 Fire Alarm Press both 4 and 6 key to trigger Fire alarm 10 Emergency Alarm Press both 7 and 9 key to trigger Emergency alarm 11 Battery Insulator 12 Mounting Knockouts 13 Tamper Switch The Tamper switch protects the PIR from unauthorized cover opening Package Content 1 x Remote Keypad 2 x wall plugs and screws 1 x 3V lithium batteries pre installed Learning For learning the Remote Keypad 1 Put the Control Panel into learning mode 2 Press both and keys to transmit learn code 3 Refer to Control Manual to complete the learning process Installation The Remote Keypad has 2 knockouts on the back where plastic is thinner for wall mounting 1 Use the two knockouts on the back to mark position on the wall at chest height 2 Drill holes into the wall using the knockouts as template FE CE Q XS 3 Fix the keypad base onto the wall with the screw and plugs provided 4 Replace the keypad cover onto the base D im gt Q Surface Fixing Knockouts x 2 O Standby Mode The Remote Keypad features a power saving feature When no key is pres
5. sed for 5 seconds the Remote Keypad will turn off automatically to conserve power When any key is pressed the Remote Keypad will wake up and turn on Active LED to indicate it is now under normal operation Keypad Setting The Remote Keypad features a Test programming mode for you to customize its setting Before you start using the Remote Keypad you should first finish configuration setting The Remote Keypad also feature a Keypad PIN code which is used to access the Test mode To enter Test Mode Enter 0000 Default Keypad PIN code x key the Active Orange LED will light up Under Test Mode the mone functions include Key Function S kK 4 87 Transmit learn code same as pressing both and keys under normal mode Enable dual key Panic Alarm function Enable dual key Fire Alarm function ok 6 Change Keypad PIN Code 1 Enter old code Status Key 2 Enter new 4 digit code key BLAUPUNKT Orange LED On k 4 8 Enable Arming without Use PIN code function Orange LED Off Fault exists in system kK 9 Enable Arm with User PIN code function Default Battery The Remote Keypad uses one 3V lithium battery as its power source It also features low battery detection function to notify the Control Panel when battery voltage is low a ig Enable Arming with KP PIN code function To leave Test Mode Arm Home Disarm If Remote Keypad is set