Home
User manual
Contents
1. WIRELESS INTERLINK WHT 630 only The WHT 630 heat alarm contains an inbuilt RF module which enables you to wirelessly interlink up to 50 Wi Safe 2 products to create a network Therefore the WHT 630 alarms need to be learned in or interlinked in order to communicate with each other or other alarms with Wi Safe 2 technology Once a network has been established if one alarm activates all other interlinked alarms will also sound Please note that WHT 630s can only be interlinked with other WHT 630s and products within the Wi Safe 2 range The process below describes learning in two alarms into a network Alarm 1 and Alarm 2 1 Install Alarm 1 as described previously 2 Install the mounting plate for Alarm 2 in one of the recommended locations Do not fit the second alarm onto its mounting plate yet 3 On Alarm 2 using a ballpoint pen or a paperclip opened out briefly push and release the learn button 9 located ina circular hole in the back of the alarm Learn in button ircular hole 4 The red LED next to the learn button will flash briefly then light up for approximately five seconds to show it s ready to receive the learn in signal During these five seconds you will need to briefly press the test button on Alarm 1 to wirelessly interlink the two alarms 5 Alarm 1 will give an audible sound co
2. be free from defects in materials and workmanship under normal residential use and service for a period of 5 years for the WHT 630 and 10 years for the HT 630 from the date of purchase Provided it is returned with postage prepaid and proof of purchase date Sprue Safety Products Ltd hereby warrants that during the 5 year period 10 year on the HT 630 commencing from the date of purchase Sprue Safety Products Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement HT 630 WHT 630 alarm will last for the remainder of the period of the Original warranty in respect of the alarm originally purchased that is from the date of original purchase and not from the date of receipt of the replacement product Sprue Safety Products Ltd reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable Proof of purchase is required This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of Sprue Safety Products Ltd s control such as Acts of God fire severe weather etc It does not apply to retail stores service centres or any distribu
3. ES asa msosi opd 3 ALARMTEST 6 WHERE TO LOCATE 2 4 2 4 3 MAINTENANCE 6 INSTALLATION 4 TROUBLESHOOTING 6 WIRELESS INTERLINK DISPOSAL 42 4 6 eee 4 ewe 7 WHT 630 ONLY 4 WARRANTY 2 7 Note This user guide is also available in large text and other formats Please call O800 141 2561 for further information IMPORTANT INFORMATION IMPORTANT This user guide contains important information regarding the operation of your FireAngel heat alarm Ensure you read this user guide fully before installing and operating this alarm If you are installing this heat alarm for use by others you must leave this guide or a copy of it with the end user IF THERE IS ANY QUESTION AS TOTHE CAUSE OFTHE ALARM ALWAYS ASSUME THAT THIS IS AN ACTUAL FIRE AND FOLLOW YOUR FIRE EMERGENCY PLANS CE D BS5446 2 2003 KM607094 W2 module contained within the WHT 630 product independently tested to RF standard ETSI EN 300 220 2 V2 3 2 2010 02 by TRaC Global Ltd 2 FEATURES e Fixed point heat alarm Class A1 with alarm point temperature 56 C 64 C Thermistor heat sensing element for accuracy reliability and stability Thermistek technology activates the alarm sooner if it predicts a significant rate of rise in temperature 10 year sealed for life battery Operating red LED flashes once approximately every 45 seconds Fault indication amber LED flashes to indicat
4. They should be at a distance no greater than 5 3m from the farthest wall no greater than 5 3m from a door to any room in which a fire might start and no greater than 5 3m from the next heat alarm NOTE HEAT ALARMS SHOULD NOT BE WALL MOUNTED Install sufficient alarms to compensate for closed doors and obstacles which may 3 interfere with the path of heat to an alarm and may prevent occupants from hearing an alarm Two storey dwelling e Hall O Bedroom Bedroom O Living Room Single storey one sleeping area Single storey two sleeping areas n Bedroom Bedroom O O Bedroom O e Smoke alarms for limited protection o Additional smoke alarms for better coverage V Heat alarms IMPORTANT These heat alarms are intended primarily for use in single Occupancy private dwellings For use in other applications the manufacturers advice should be sought INSTALLATION IMPORTANT Please read WHERE TO LOCATE before installing the alarm Fit the mounting plate to the ceiling using the screws provided To fit the alarm to the mounting plate included in this pack position the alarm on the plate then turn clockwise until the alarm is locked into position Make sure that the alarm is twisted fully The power pack will now activate The red LED on the front of the alarm should flash once approximately every 45 seconds to show that it is active
5. e a low battery condition or alarm fault See Troubleshooting Central Test Silence mfx button Tests circuitry battery and sounder Loud 85 decibel piezo sounder Automatically resets when alarm condition has passed Easy installation Fixings supplied Silencer In the event of a known false alarm your alarm can be temporarily silenced by briefly pressing the central test button Your alarm will automatically return to full sensitivity within 10 minutes WHT 630 includes Wi Safe 2 technology allowing you to wirelessly interlink up to 50 heat alarms smoke alarms and accessories which contain Wi Safe 2 technology These may be either battery or mains powered WHERE TO LOCATE For the best protection heat alarms should always be installed as part of a complete fire protection system that also includes smoke alarms Heat alarms are best suited to areas where dust fumes and moisture can cause nuisance alarms in smoke alarms such as e Boiler rooms e Kitchens e Laundry rooms e Lofts e Garages Heat alarms should not be installed in escape routes instead of smoke alarms They should only be used in the above applications and where possible be interlinked to smoke alarms Smoke alarms should be installed in circulation areas forming part of the escape routes and in every room in the house When heat alarms are installed in a room they should be placed on the ceiling ideally in the centre of the room
6. in the network It will then become part of the network You do not have to learn in to each alarm in the network After completing the learn in procedure test the alarms as described in ALARM TEST If any interlinked alarm fails to respond to the ALARMTEST remove it from its mounting plate and repeat the learning in process ALARM TEST 1 Briefly press the test button in the centre and release 2 The unit will give an audible alarm consisting of 2 cycles of 3 loud beeps then stop automatically 3 The red LED on the alarm will flash rapidly during the audible signal As with all electronic alarm products you should test your heat alarm every week as well as any other interlinked alarms WARNING The electronic test button provides a full test of the alarms functionality DO NOT try to test the alarm with a naked flame as this might present a fire hazard in itself MAINTENANCE Vacuum every three months to help keep the unit working efficiently Vacuum the exterior Prevent vacuum from touching the unit WARNING Never attempt to open or damage the battery TROUBLESHOOTING If your heat alarm chirps intermittently Check the location of your alarm e If the alarm chirps every 45 seconds and the yellow LED flashes at the same time this indicates that the power pack is low Replace the unit within 30 days WHT 630 only If the alarm chirps every 4 ho
7. nsisting of 2 cycles of 3 loud beeps The red LED on the wireless module of Alarm 2 will flash to indicate that it has been learned in successfully AN Cey D 6 PLEASE NOTE If the test button is not pressed quickly enough before the red LED on Alarm 2 has gone out the learn in process will fail If this happens repeat the process again as described above 7 Fit Alarm 2 onto its mounting plate to complete the installation Additional alarms should be learned in in the same way When learning in additional alarms any alarm already in the network can be used as Alarm 1 This means that you can learn in the additional alarm into any alarm already
8. tors or agents Sprue Safety Products Ltd will not recognise any changes to this warranty by third parties Sprue Safety Products Ltd shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration for 5 years on the WHT 630 and 10 years on the HI 630 This warranty does not affect your statutory rights Except for death or personal injury Sprue Safety Products Ltd shall not be liable for any loss of use damage cost or expense relating to this product or for any indirect or consequential loss damages or costs incurred by you or any other user of this product Please see the back cover of this guide for contact details DIGITALLCD CARBON MONOXIDE ARM 7 YEAR LIFE mi Are you protected from deadly carbon monoxide For a full range of carbon monoxide alarms Technical Support Line 0800 141 2561 UK Textphone users dial 18001 0800 141 2561 EIRE dial 1 800 523171 O A Sprue Brand Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK visit Www sprue com Email technicalsupport sprue com Web www sprue com HT 630 WHT 630 GN2673 R1 User Guide Firefingel THERMISTEK Heat Alarm HT 630 THERMISTEK Heat Alarm with Wireless Interlink WHT 630 Wi Safe f CONTENTS FEATUR
9. urs another alarm in the network has a low power pack and needs replacing If the yellow LED is flashing and the alarm is chirping o If the yellow LED flashes at a different time to the chirp this means there s a fault with your alarm and it needs replacing If your heat alarm does not sound during testing e Push the centre test button firmly e If the unit has been silenced and is in low sensitivity mode it may not sound Wait 15 minutes e Make sure the alarm is securely located into the mounting plate If the alarm fails to operate correctly the advice of the manufacturer should be sought by contacting Technical Support on 0800 141 2561 DISPOSAL Waste electrical products should not be disposed of with your other household waste Your alarm does not contain any ME radioactive material This means that the alarm is ideally suited for disposal within the waste electronic and electrical equipment WEEE recycling scheme Please recycle where facilities exist Check with your local authority retailer or contact our technical support team for recycling disposal advice as regional variations apply Once the alarm is removed from the mounting plate the internal power pack battery will be deactivated The unit is now ready for disposal WARNING Do not attempt to open WARNING Do not burn or dispose of in fire WARRANTY Sprue Safety Products Ltd warrants to the original purchaser that its enclosed heat alarm
Download Pdf Manuals
Related Search
Related Contents
TÉLÉVISION & cINÉma SafeTNet - User Manual GTO Mighty Mule 352 User's Manual Royal Sovereign 900NPH-1200N User's Manual Acer Altos 180F1 Scalasca User Guide - Forschungszentrum Jülich Copyright © All rights reserved.
Failed to retrieve file