EX-EN300 Gebruikershandleiding / Manual

image

Contents

1. selected by a front panel button e Dual display with simultaneous display of relative humidity and temperature or air velocity and temperature e Zero button for light meter e Robust housing suitable for one hand operation 2 EN300 EU EN V1 1 doc 6 11 Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information O Double insulation Cautions e Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter e Inspect the condition of the probe and the meter itself for any damage before operating the meter Repair or replace any damage before use e If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired e This device is not a toy and must not reach children s hands It contains hazardous objects as well as small parts that the children could swallow In case a child swallows any of them please contact a physician immediately s Do not leave batteries and packing material lying around unattended they can be dangerous for children if they use them as toys e Incase the device is going to be unused for an extended period of time remove the batteries to prevent them from draining e Expired or damaged batteries can cause cauterization on contact with the skin Always therefore us
2. are sold Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 7 EN300 EU EN V1 1 doc 6 11 Specifications General Specifications Display Measurement Operating Humidity Operating Temperature Over Input Display Data Output Power Supply Power Consumption Weight Dimension Electrical Specifications Anemometer Air velocity Temperature LCD display LCD size 41 5 x 31 5 mm 5in1 Anemometer Air velocity Temperature Humidity RH Temperature Light Thermometer type K Sound level 80 RH Max 0 to 50 C 32 to 122 F Indication of RS 232 USB PC serial interface 1 5 DC V battery UM4 AAA x 6 PCs 9V DC adapter input AC power adapter is optional Anemometer Approx DC 11 mA Other functions Approx DC 7 5 mA 335 g 0 74 lb battery included HWD 248 x 70 x 34 mm 9 8 x 2 8 x 1 3 inch Units Range Res Accuracy ft min 80 to 5910ft min 1 lt 3900ft min 3 F S gt 3900ft min 4 F S m s 0 4 to 30 0m s 0 1 lt 20m s 3 F S gt 20m s 4 F S km h 1 4 to 108 0km h 0 1 lt 72km h 3 F S gt 72km h t 4 F S MPH 0 9 to 67 0mile h 0 1 lt 45mile h 3 F S gt 45mile h 4 F S knots 0 8 to 58 3 knots 10 71 39 knots 3 F S gt 39 knots 4 F S SE 32 to 122 F 0 1 2 5 F PC 0 to 50 C 0 1 1 2 C Type K Thermocouple Thermometer Uni
3. User s Guide EXTECH INSTRUMENTS A FLIR COMPANY 5 in 1 Environmental Meter Model EN300 Anemometer Humidity Meter Light Meter Thermometer Sound Level Meter CE Introduction Congratulations on your purchase of this Extech Meter The EN300 is five professional meters built into one convenient package This meter ships fully tested and calibrated and with proper use should provide many years of reliable service Features This 5 in 1 professional measuring instrument provides the following functions 1 2 3 Anemometer uses a low friction ball bearing mounted wheel design for high accuracy Humidity meter uses a high precision humidity sensor for fast response time Light meter uses a photo diode and color correction filter light sensor spectrum meets C I E photopic Type K thermometer uses standard type K NiCr NiAl thermocouple input jack suitable for diverse application type K probes The sound level meter meets IEC 61672 class 2 with A frequency weighting and Fast time response Common Features e Built in microprocessor circuit assures excellent performance and accuracy e Concise and compact button arrangement for ease of operation e Record recall maximum and minimum values e Hold function freezes the current reading value e Front panel C F selection button e Front panel Lux Foot candle selection button e Five 5 air velocity measurement units
4. e suitable hand gloves in such cases e See that the batteries are not short circuited Do not throw batteries into the fire 3 EN300 EU EN V1 1 doc 6 11 Meter Description O00 NN Oy OB ON Be a yor te E OM oS Oo Microphone Light Sensor LCD display Hold Button Power Button Unit Zero Button Air Speed Sensor Thermocouple Input Socket 2 RS 232 Output Terminal AC power adaptor socket 3 Max Min Button ki Function Button 4 C F Button Lux Ft cd Button On rear Battery Compartment Tripod mount 7 Stand 8 EN300 EU EN V1 1 doc 14 11 12 13 6 11 Operation Powering the meter 1 2 3 Press the Power button to turn the instrument ON If the meter does not turn on or if the C_X_ low battery symbol appears in the display replace the batteries Press the Function button to select the measurement needed Note The display orientation rotates depending on the function selected Microphone up Sound Light Temperature Air speed sensor up Airspeed Temperature Humidity Temperature Anemometer Air Velocity Measurement 1 D WK ON Select the Anemometer function by pressing Function Button until the display indicates Anemometer units ft min m s km h MPH or knots Press the Unit Zero Button to select unit desired Press the C F Button to select the temperature unit Face the air velocity sensor into the source of
5. pressing the Function Button until a light unit Lux or Ft cd is displayed 2 Press the Lux Ft cd Button to switch between Lux or Ft cd 3 The Display will show the light value Zero Offset calibration of Light Function For best results zero the light sensor prior to use in a dark environment To accomplish this completely cover the light sensor and then press the Unit Zero Button The zero point can drift due to environment temperature and battery power change lt is recommended that the zero be checked frequently using the above procedure Sound Level Measurement 1 Select the Sound Level function by pressing the Function Button until the Sound level unit dB is displayed 2 Hold the instrument in one hand and point the microphone towards the noise source The sound level value dB will be displayed on the LCD 6 EN300 EU EN V1 1 doc 6 11 Changing C F units During temperature measurements press the C F button once to change the temperature units from C to F Hold Function Press the Hold Button to freeze the current reading value HOLD symbol appears on the display Press the button again to continue normal operation Data Record Function 1 The Data Record function records amp displays the maximum and minimum reading values Start the Data Record function by pressing the Max Min Button once The REC symbol appears on the display 2 With the REC symbol on the display a P
6. ress the Max Min Button once and the Max symbol along with the maximum value will appear on the display b Press the Max Min Button again the Min symbol along with the minimum value will appear on the display c To exit the memory record function press the Max Min Button continuously for at least 2 seconds The display will revert to the current reading d Clear the Max Min value recorded by pressing the Hold Button once Previous recorded Max Min values will be erased and then return to REC function and continue recording Auto Power off To prolong the life of the batteries the instrument has an Auto Power off function The meter will automatically switch off if there are no button presses in any 10 minute period RS232 port The RS232 port is used to send measurement data to a PC Battery Replacement 1 When the LCD display shows WS 9 symbol it is necessary to replace the battery However measurement may still be made for several hours after the low battery indicator appears 2 Remove the two battery cover screws and remove the battery cover 3 Install fresh batteries DC 1 5 V battery UM4 AAA x 6 PCs and reinstall the cover You as the end user are legally bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators
7. ts Range Resolution Accuracy F 148 to 2372 F 0 1 F 1 rdg 2 F PC 100 to 1300 C 0 1 C 1 rdg 1 C Note The type K thermocouple probe is optional 8 EN300 EU EN V1 1 doc 6 11 Hygrometer Humidity Temperature Units Range Resolution Accuracy lt 70 RH 4 RH RH 10 to 95 RH 0 1 RH 70 RH 4 rdg 1 2 RH F 32 to 122 F 0 1 F 2 5 F C 0 to 50 C 0 1 C 1 2 C Light Units Range Resolution Accuracy 0 to 2 200 Lux 1 Lux Lux 1 800 to 20 000 Lux 10 Lux 5 rdg 8 digits 0 to 204 0 Fc 0 1 Ft cd Ft cd 170 to 1 860 Fc 1 Ft cd Sound Level Microphone 2 Electret condenser microphone Measurement Range 35 to 130 dB Auto range Resolution 0 1dB Frequency response 31 5Hz to 8 000Hz Weighting A frequency weighting network Time Response Fast Accuracy Meets IEC 61672 class 2 A weight Fast response Note Stated specification tests under the environment RF Field Strength less than 3 V M amp frequency less than 30 MHz only Note Specification stated for 23 5 C Copyright 2011 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form www extech com EN300 EU EN V1 1 doc 6 11
8. wind The display will show the air velocity and the ambient temperature Allow time for the reading to stabilize and note the values indicated Air velocity may fluctuate slightly Temperature Measurement Thermocouple 1 2 3 4 Plug a type K thermocouple probe into the Thermocouple Input Socket Select the temperature function by pressing Function Button unit the display shows temperature units C or F Contact the Thermocouple Sensor Head with object to be measured The temperature value will be displayed on the LCD display Note Verify the polarity when plugging a thermocouple probe into the temperature input socket Any temperature difference between thermocouple probe and thermometer can result in inaccurate measurement result Therefore allow time for thermal equalization between probe plug and meter input socket The thermal equalization procedure takes few minutes and should be applied only when the probe has been exposed to ambient temperature different from the meter 5 EN300 EU EN V1 1 doc 6 11 Hygrometer Humidity amp Ambient Temperature Measurement 1 Select the Relative Humidity function by pressing Function Button until the display indicates RH 2 The humidity and temperature readings will be displayed on the LCD 3 When the meter is placed into a new environment a few minutes are required to reach a stable condition Light Measurement 1 Select the Light Measurement function by