Home
User`s Manual
Contents
1. the link succeeds Also refer to Fig 10 and Fig 11 for the erroneous status when TP Cable A Fiber Cable B or Fiber Cable C fails to connect Note Link fault pass through LFP function only takes effect as S1 Bit2 see Fig 15 is enabled Disabled S1 Bit2 will turn this media converter into a general one GbE GbE Remote Switch Switch Station Fiber e Cable o Fig 5 Normal status via LFP converter GbE GbE Remote Switch Switch Station ee a Fiver OO Cable O O Fig The status as TP Cable A or D is rake GbE GbE Remote Switch Switch Station ee a Fiber OO Cable O O Fig i The status as Fiber Cable B or C is Er GbE Fiber GbE Remote Switch Switch Station A q E Fiber o Cable ee MICROSENS GbE Fiber E Remote Station Fig 12 Normal status via LFP converter Fig 13 The status as TP Cable A is broken i GbE R e aei Switch Stailon Fb re o O O Fig 14 The sas as Fiber Cable B or C is oe Note Indicates LNK ACT LED Lit O Indicates LNK ACT LED Off Notice The LFP Link Fault Pass Through function can work with different link partners for Example Fiber port on Switch It does not need both two converters with the same model in pairs MICROSENS 6 LED Description LED Color Function Lit when fiber connection is good bid reen Blinks when fiber data is Se Lit when TP connection is good TEENIE Green Blinks when TP da
2. 000SX SC LC 160 220m 400 500m 850nm 200 275m 500 550m 1000LX SC LC Single Mode Fiber 9 125um 1310nm Single Mode transceiver 1310nm 10Km 1550nm Single Mode transceiver 1550nm 30 50Km 9 PoE PSE TP Fiber Technical Specifications e Standards e UTP Cable e Fiber Cable IEEE802 3u 10 100Base TX 100Base FX IEEE802 32z ab 1000Base T IEEE802 3af Power over Ethernet Cat 5 cable and up to100m 50 125 62 5 125 or 100 140m multi mode 8 3 125 8 7 125 9 125 or 10 125um single mode e PSE Power Feeding Supports Endpoint via TP pin 1 2 3 6 e LED Indicators POWER PoE TP LNK ACT SPD FX LNK ACT 4W 7W 15 4W e Data Transfer Rate Speed Forwarding Rate 1000Mbps 148 8000 PPS 100Mbps 148 800 PPS 10Mbps 14 880 PPS e Flow Control IEEE802 3x compliant for full duplex Backpressure flow control for half duplex e Power Requirement AC Line 100 240V 50 60Hz e Power Consumption 24W e Ambient Temperature 0 to 50 C e Humidity 5 to 90 MICROSENS e Dimensions 40 H x 158 W x 133 D mm e CE Mark Note For connecting this device to Router Bridge or Switch please refer to the corresponding device s Technical Manual
3. EN61000 3 3 1995 A1 2001 A2 2005 A1 2001 A2 2005 EN55024 1998 A1 2001 A2 2003 gt 1EC61000 4 2 2001 gt 1EC61000 4 3 2002 A1 2002 gt 1EC61000 4 4 1995 A1 2000 A2 2001 gt 1EC61000 4 5 2001 gt IEC61000 4 6 2003 gt 1EC61000 4 8 2001 gt 1EC61000 4 11 2001 EMS MICROSENS 1 Overview 10 100 1000Base T to 1000Based SX LX SC LC EEE802 3z ab GbE media converter which allows two types of network segments to be connected easily and inexpensively Complied with IEEE802 3af Power Over Ethernet standard this AC powered PoE media converter is a Power Sourcing Equipment PSE which combines data received over a TP link with 48VDC power providing power to IEEE802 3af powered device PD over the existing CAT5 UTP cable The converter includes a PD signature sensing and power monitoring features Other features include over current protection under current detection and fault protection input The LFP Link Fault Pass through allows the media converter to monitor both the fiber and copper RX ports for loss of signal In case of a loss of RX signal on one media port the converter will automatically disable the TX signal to the other media port thus passing through the link fault FEF Far End Fault enables the converter to stop sending link pulse to the link partner once a loss of the fiber RX signal is encountered Then the link partner will synchronously stop sending data FEF prevents loss of
4. MICROSENS User s Manual 10 100 1000Base T to 1000Base X PoE PSE GbE Media Converter Release 1 0 MICROSENS Table of Contents CAUTION titi EA A A EA AA AAA A A 4 Te OVERVIEW a a acia 5 2 MODEL DESCRIPTION uta ad Dn tb e a hi Dt A 5 Bz CHECK TALE A A a a dt a a LI AE 5 4 INSTALLING THE GONVERTER cities add dd bata deus 5 5 LINK FAULT PASS THROW GH tt ia ia dete tutte 8 6 LEED DESGRIPTION Ha dE td at ciated desea ees dete da 10 7 DIP SWITCH AND RESET BUTTON coooccccccccnonononononccancnnnonnnancnnnnnnnonnnncannnnnnnnnnnnannnn cnn nn ninas 10 8 CABLE CONNECTION PARAMETER moei na a i a i a i E 11 9 POE PSE TP FIBER TECHNICAL SPECIFICATIONS occcccononononcnncncononcnnnancnncnnononnnncnncnncnnnnnnnnas 11 ii MICROSENS MICROSENS Caution Circuit devices are sensitive to static electricity which can damage their delicate electronics Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge To protect your device always e Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device e Pick up the device by holding it on the left and right edges only European Community CE Electromagnetic Compatibility Directive This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022 and EN55024 EN55022 2006 Class A EMI EN61000 3 2 2006
5. nly 1000Base SX LX SC LC with NWay flow control Link partner must be 1000FDX with NWay flow control Fiber Port Fig 1 The View of PoE PSE Media Converter Gigabit Fiber Network y Fiber Optic Cat 5 Cable RJ 45 Jack PD Device Refer to Fig 6 MICROSENS Fig 2 Connection among PSE PoE Converter Fiber and TP Cables PoE PD or 7 E POE Splitter Fig 3 PSE to PD or PoE Splitter Fig 5 PoE PSE Media Converter Rear Panel Signal pairs RJ 45 CAT 5 connector 5543 2 1 k cable 8 7 Fig 6 Endpoint PSE RJ 45 Male Connector Note IEEE802 3af assigns pairs on the RJ 45 connector and Cat 5 cable of Endpoint PSE MICROSENS Endpoint 48V via TP pin 1 2 3 6 5 Link Fault Pass Through The Converter model of LFP link fault pass through in TX FX converter application is controlled by the software and instantly takes effect Link status on one port is propagated to the other port to notice the remote nodes If TP port is unplugged this converter stops transmission on fiber port This causes the remote fiber node link to fail LED shows the link failure on both TP and fiber ports If fiber link fails this converter restarts auto negotiation on TP port but always stays in the link failure state This causes the remote TP node link to fail LED also shows the link failure on both TP and fiber ports Refer to Fig 9 shown below for the normal status when
6. ta is ae Creer Green Lit when TP speed is 1000Mbps TP SPD Amber Amber Lit when TP speed is 100Mbps Off when TP speed is 10Mbps PWR Green Lit when 5V power is coming up Green Lit when PoE feeding power is active PoE PSE TP Red Lit when PoE feeding power is disrupted In case of overtemperature overcurrent 4W Green Light when PD Class Type is Class 1 7W Green Light when PD Class Type is Class 2 15 4W Green Light when PD Class Type is Class 0 or 3 7 DIP Switch and Reset Button le S 3 g E a 1 2 O sia 304 EN 30a BUON Fig 15 Reset button and Si Bit 1 2 3 Configuration and Setting Reset Once S1 1 S1 2 is changed please press this button to have the setting taken effect S1 1 Bridge mode Cut through default or Normal 1 2 LFP i LFP enabled default or disabled S1 3 PoE ON OFF Enable default or disable Note 1 S1 1 Cut through mode support jumbo frame size max up to 9216Bytes Normal mode max frame size up to 2048 Bytes 2 S1 3 Must be set to PoE ON while power supplies to PD 8 Cable Connection Parameter MICROSENS 1000Base SX LX network only support full duplex mode The Switch based Media Converter breaks up TP and Fiber segments collision domain to extend the cabling distance e TP Cable Limitations Cat 5 and up to 100m e Converter Fiber Cable Limitations 62 5 125um 50 125um Bandwidth Distance Bandwidth Distance MHz Km MHz Km 1
7. valuable data transmitted over invalid link Combining LFP and FEF troubleshooting features both end devices can be notified of a loss of fiber link 2 Model Description Model Description 10 100 1000Base T to 1000Base SX PoE PSE MS400080 GbE converter MM SC 10 100 1000Base T to 1000Base LX PoE PSE MS400082 GbE converter SM SC 10km 3 Checklist Before you start installing the Converter verify that the package contains the following The PoE PSE TP Fiber Converter AC Power Cord This User s Manual Please notify your sales representative immediately if any of the aforementioned items is missing or damaged 4 Installing the Converter PSE TP Fiber Converter with Powered Device PD Connect the PSE media converter to an AC power source Install the TP media cable to the IEEE 802 3af PD converter MICROSENS See Fig 2 Note It can work as a pure converter that connects to the non PoE converter gt Install the media cable for network connection Warning gt Verify that the AC input conforms to your country AC power requirement and then insert the power plug gt Ensure that the power of PSE device is turned on Install the media cable for network connection 10 100Base TX Auto Negotiation Auto MDI X flow control for Full Duplex TP Port backpressure for Half Duplex 1000Base TX Auto Negotiation mode Auto MDIX only for Auto Negotiation flow control for Full Duplex o