Home

Manual - Ono Sokki Technologies

image

Contents

1. 10 Roller width 4mm Material SKS3 Material SUj2 M2 5 X 0 45 B E Outer dimensions 22 0 3Plane 01 5 Roller width 7mm Material SUj2 Material SKS3 Material SKS3 Tip ball material Ruby 1 When affixing a flat gauge head such as the AA 0220 0240 0250 921 to a gauge with a measurement resolution of 0 05um 1pm adjustment of the degree of parallelization to match that of the surface of the measurement stand is required In this case the gauge head and stand must be purchased as a pair additional cost required 2 When affixing a roller gauge head such as the AA 827 828 to a gauge with a measurement resolution of 1m there may be times when the precision specification cannot be achieved The AA 827 828 uses a bearing but as the gap cannot be eliminated an error of approximately 10um may appear g Extension spindle Model name Material SUS303 Material SUS303 M 2 5 al M 2 5 Outer dimensions g Others Extension cable AA 8801 5m AA 8802 10m AA 8803 20m AA 8804 30m T 0230 URL http www onosokki co jp English english htm ONO SOKKI e Outer appearance and specifications are subject to change without prior notice U S A THAILAND P R CHINA WORLDWIDE Ono Sokki Technology Inc Ono Sokki Thailand Co Ltd Ono Sokki Beijing Office Ono Sokki Co Ltd 2171 Executive Dr
2. GS 4700 4800 series GS 6700 6800 series Conforming to protection class IP66G GS 4700 4800 series and IP64 GS 6700 6800 series the GS 4700 4800 and GS 6700 6800 series sensors are designed to be used in harsh environments A resolution of either 1 um or 10 um can be selected in accordance with the measurement application All models are compatible with our DG 4000 series of digital gauge counters which have comparator offset peak hold multiplying and other functions depending on the model ONO OKKI Digital Linear Gauge Sensors LINEAR GAUGE SENSOR 3 A selection of eight models suitable for installation in production lines with environments subject to dust water splashes or and oil splashes Features Conforming to environmental protection class IP64 or IP66G Various optional parts Compatible with DG 4000 series Compact and small body with high accuracy High cost performance Structure Conforms to the IP64 66G Protection Class ________ The IP64 66G International Protection number code indicates the protection class with respect to the penetration of dust water and oil IP6X indicates that the enclosure is dust tight with no ingress of dust IPX4 indicates that the enclosure is protected against drops of water and splashing water Water splashed against the enclosure from any direction shall have no harmful effect IPX6 indicates that the enclosure is protected against heav
3. ive Suite 400 29 67 Moo 5 Tivanon Road Pakkred Beijing Jing Guang Center 3510 3 9 3 Shin Yokohama Kohoku ku Addison IL 60101 U S A Nonthaburi 11120 Thailand Hu Jia Lou Chao Yang Qu Yokohama 222 8507 Japan Phone 1 630 627 9700 Phone 66 2 964 3884 Beijing 100020 P R China Phone 81 45 476 9712 Fax 1 630 627 0004 Fax 66 2 964 3887 Phone 86 10 6597 3113 Fax 81 45 470 7244 E mail info onosokki net E mail osth_sales onosokki co jp Fax 86 10 6597 3114 E mail overseas onosokki co jp http www onosokki net E mail onosokki bbn cn CAT NO 040906 013 SK 107
4. r is taken as the error This is the reason why the d display accuracy of a sensor with a resolution of 10um is lower than that of a sensor with a resolution of 3um see Fig 2 Measurement force The force used to hold down the workpiece is called the measurement force Since our gauge sensors feature an internal spring return mechanism for the spindle the measurement force is the force measured at the maximum extension limit The force unit is expressed as N Newton The measurement force can be changed by replacing the spring Please specify your requirements when placing your order Please note that depending on the modification there may be times when the attachment does not return completely if it is facing upwards or sideways Likewise you will need to consult us if modification to a fixed value see below is required Reference displacement meter Error d d 1 If for example modification to a fixed value for a linear gauge sensor with a measurement range of 13mm was made the measurement force for the amount moved within the 0 to 13mm range becomes a fixed value variation of 10gf 6700 6800 series GS 4700 4800 g Output signal circuit GS 47 13 4730 4813 4830 6713 6730 6813 6830 Connector RO3 PB6M Signal connector RO3 PB6M product of TAJIMI ELECTRONICS CO LTD Signal name nacoo Line color SIG1 Yellow SIG 1 Yellow White SIG 2 White Orange t 45V IN O
5. range Not connected Gray No connection i COM Gray COM Pink At Ono Sokki we recommend the use of a linear gauge sensor together with a digital gauge counter If you plan to use a linear gauge sensor without an Ono Sokki digital gauge counter please refer to the specifications in the user s manual for the sensor and or other materials to design your own gd Outer Dimensions GS 4713 4813 Connector RO3 PB6M by TAJIMA GS 4730 4830 Connector RO3 PB6M by TAJIMA GS 6713 6813 Connector RO3 PB6M by TAJIMA Cable length Approx 1 9m GS 6730 6830 Connector RO3 PB6M by TAJIMA Cable length Approx 1 9m 015 5 015 5 ir 4 LINEAR GAUGE SENSOR 30mm 119 5 62 5 82 5 g Specification o ead GS 4713 GS 4730 65413 GS 4830 GS 6713 GS 6730 656813 GS 6830 Resolution tm tm _ C R 10m tm Accuracy at 20 fm fm __ __aym fam a Number of sliding times proven in our endurance test 15 million or more 5 million or more Protection class l i P64 excluding connector section IP66G IPG Stem diameter 1 Bd mm 4 5 to 5 5VDC Power consumption when 5VDC 120mA or less Signal output when 5VDC Two phase square wave Phase difference 90 20 Output voltage Hi 4 5V or more Lo 0 4V or less Output impedance Approx 220 when the power is off 10 cycles of 10 to 150Hz sweep 10 c
6. y seas or powerful jets of water With no ingress of water jets from any direction IPXXG indicates that the enclosure is protected against oil drops and oil splashes Oil splashed against the enclosure from any direction shall have no harmful effect O Compatible digital counters DG 4140 Comparator output BCD Color backlight DG 4120 BCD output DG 4190 Comparator output Analog Color backlight DG 4240 Comparator output Upper amp Lower DG 4280 Comparator output 4 preset ONO SOKKI et eee Pf fl es LF 5 2 d 0G 4140 Digital Gasge Counter met Darta Gave COMPARATOR OA Brief Explanation of Terms Display Accuracy Fig 1 l um MAX This is the measurement error inherent in a linear gauge sensor The error the amount of difference from the actual value is measured at each specified mm measurement value and when the overall length of the spindle movement is b considered the sum of the absolute values of the maximum error in the positive direction and of the maximum error in the negative direction becomes the display Ae Display accuracy al Ib accuracy of that gauge sensor see Fig 1 Measurement of the accuracy is performed by making comparisons with a Fig 2 z P reference displacement meter The difference between the reading value at the a saan ete time that the lowest order digit of the target sensor changed and the value of the reference displacement mete
7. ycles of 10 to 150Hz sweep Shock resistance 1960m s in each direction for each of three axes three times for 1470m s in each direction for each of three axes three times for when the power is off each of X Y and Z directions sine half wave pulse duration 6ms each of X Y and Z directions sine half wave pulse duration 6ms 0 to 40 C 10 to 55 C Operating temperature range Cable length Weight including cable and connector Approx 5m Approx 1 9m Approx 385g Approx 325g Approx 385g Approx 250g Approx 310g Approx 250g Approx 310g Approx 325g 1 When used with Ono Sokki s digital gauge counter The values within parentheses are the maximum spindle velocity used with the DG 4140 4190 5100 2 An attachment may not return completely if it is facing upwards 3 Vibration shock resistance values described in above are not guaranteed during measurement operation e Disconnected or modified signal cable is not applicable to CE marking Optional accessories and P g Contact tip Model name AA 0200 AA 0210 AA 0220 AA 0230 M2 5 X 0 45 5 M2 5 X 0 45 M2 5 X 0 45 M2 5 X 0 45 Outer dimensions Material SKS3 Material SKS3 Material SKS3 Model name AA 0250 AA 0260 AA 827 2 M2 5 X 0 45 M2 5 X 0 45 M25 X 0 45 r M2 5X 0 45 4 Outer dimensions

Download Pdf Manuals

image

Related Search

Related Contents

TX-SR500 TX-SR500E  Insignia NS-DVDR1 User's Manual  01-16.ps, page 1 @ Preflight ( 01-16.indd )  ACC-22B - Hoffer Flow Controls, Inc  ASUS (ME170C) User's Manual  1.日常点検  Gefen EXT-DVI-FM2000 User's Manual  Enjeux de l`évaluation  Télécharger la biographie complète de Gessen Masha  Model 4002P Portable Power Supply Operating and Service Manual  