Nx56/64 - ADTRAN Support Community
Contents
1. Plug On Boardi onat aaneen nennen 2 Features of the 2nd GEN Nx56 64 Option Module ee 3 Interfaces n noni na a tase a a a oaii 3 2nd GEN Nx56 64 V 35 Option Module Specifications 4 Physical Descriptio iussione ienei e i ais 5 Chapter 2 Installation Unpack amp Inspectii i len 7 ADTRAN Shipments Include enenseneenneeesneenene nenne 7 Customer Proyvides n tens a S A i 7 Installing The Option Module 2 220220nserneenneenneennenneen nennen 8 Placement of the Option Module ennenenennennn 8 Power Connection aaa S 8 Attaching the Plug On Board c eneneneeneenseenseen nennen 9 Warranty and Customer Service uessseneesseenseeseeneenennnen nennen nenn 10 Wiring ante HIER BAER 11 Power Up Testing and Initialization uuessseeesenneenneenneeneennnen 12 Chapter 3 Operation Overview rer oat A TE aah ses aa a A ena a OEE 13 Front Panel Indicators Buttons cccccccccccccceseeessssececceeceseesssseeeeeecens 13 Menu Structure u ruhen en oa EE TE E a lest 13 2nd GEN Nx56 64 V 35 Menus Are All Submenus 222 000 14 Operation 2 0 erian eiin AER tsetse AE AE EA e eed aE 14 2 PORT Status Submenu of 1 Status uaeseeeaanneeesnnnneeeesnnneeeenenennn 16 Operation ER E EAEE A E A E A E 16 7 PORT CONFIG Submenu of 2 CONFIG naecnnnnnennennneeennnn 17 Oper
2. 3 7 Display of Port Name and Software Version Press the Cancel key to exit or to select another port 2 RUN SELF TEST Submenu of 4 TEST 22 This menu item is used to execute both the internal test of the TSU HSU and of the 2nd GEN Nx56 64 This is the same test executed during power up The results of the self test are shown on the TSU 100 display For additional information on self test see the chapter Operation in the appropriate TSU HSU user manual To activate a self test do the following l Follow the standard operating procedure to access the 4 TEST menu items 2 With the cursor on 2 RUN SELFTEST press the Enter key This results in a changing TSU HSU display showing the test outcome 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 3 Operation 3 PORT TEST Submenu of 4 TEST NOTE Operation This menu item is used to activate testing of specific data ports It also controls the activation of loopbacks and the initiation of data test patterns Test results are shown on the TSU HSU display The execution of Port Tests disrupts normal data flow in the port being tested To display Figure 3 8 on the TSU 100 starting with the cursor on 3 PORT TEST press the Enter or number 3 key This displays the available ports Figure 3 8 Port Test Submenu 1 1 2nd GEN Nx56 64 The Nx interface offers the following test functions 1 LOOPBK Initiates a loopback PRT LCL The Nx por
3. 4 V 35 option module Operation To display Figure 3 4 on the TSU 100 starting with the cursor on Main menu item 2 CONFIG do the following 1 Press the Enter or the number 2 key This displays the first two Configuration submenu items with the cursor on 1 NETWORK NI 2 Use the Scroll Down key to place the cursor on 7 PORT CONFIG and press the Enter key 3 Use the Scroll keys to identify 1 1 2nd GEN Nx56 64 V 35 option module Only the bottom line of the display changes 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 17 Chapter 3 Operation Figure 3 4 Port Configuration Submenu To select Port Configuration press the Enter key This displays the first of eight submenu items They are defined as follows 1 INTERFACE This selects the active interface for the Base Nx port The Nx ports which are installed as option modules have only one type of interface Choice V 35 2 RATE 56 64 This sets the base rate of the interface The actual data rate depends on the number of DS0s assigned to the Nx port The DTE data rate versus the number of DSOs appear in the appendix DTE Data Rate Chart of the TSU 100 User Manual Choices 56K or 64K 3 TX CLK Controls the clock used by the TSU 100 to accept the transmit TX data from the DTE Normally this is set to Normal If the interface cable is long causing a phase shift in the data the clock can be selected as Inverted This switches the phase of t
4. ADRAN Nx56 64 Second Generation Option Module PN 1202054L1 Plug On Board PN 1202053L1 USER MANUAL 61202 054L1 1B February 1996 ADRAN 901 Explorer Boulevard P O Box 070020 Huntsville AL 35807 Phone 205 971 8000 Fax 205 971 8699 1996 ADTRAN Inc All rights reserved Printed in USA FEDERALCOMMUNICATIONSCOMMISSION RADIOFREQUENCY INTERFERENCESTATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications to this unit not expressly approved by the party responsible or compliance could void the user s authority to operate the equipment Table of Contents Chapter 1 Introduction Second Generation 2nd GEN Nx56 64 V 35 Option Module Overview 1 2nd GEN Nx56 64 V 35 Plug On Board Overview eneeene 1 Functional Description of the 2nd GEN Nx56 64 V 35 Option Module nd
5. ation nn rnit 17 3 FACTORY RESTORE Submenu of 3 UTIL u 21 Oper ti n nenne u Ri 21 7 PORT UTILITY Submenu of 3 UTIL a nennen 21 Operation vieices ens aan 21 2 RUN SELF TEST Submenu of 4 TEST 2 22 3 PORT TEST Submenu of HTEST nennen 23 Operation a a n asien seinen E AEA Ea ET EES ER ES 23 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual I Table of Contents Appendix A TSU HSU X00 System Messages Alarm Messages taneet ae in ose aa bees e 25 Network Interface N Dianani aget ee E RO 25 2nd GEN Nx56 64 V 35 Option Module eeeeenn 25 Status Messages nn E R ANE E A S 26 Network Interface ND esesenensenneneesensenseneneesensenne seen 26 2nd GEN Nx56 64 V 35 Option Module eeeeenn 26 List of Figures Figure 1 1 2nd GEN Nx56 64 V 35 Option Module 5 Figure 2 1 Installing the Option Module uesseensenseseennennennnnn 8 Figure 2 2 Attaching the Plug on Board eneeneeneennee 9 Figure 3 1 TSU 100 Main Menu Tree 0 cece eee eee cee etree ee teeeteeeeeees 14 Figure 3 2 2nd GEN Nx56 64 V 35 Option Module Menu Tree 15 Figure 3 3 Port Status Submenu ou cece e A O 16 Figure 3 4 Port Configuration Submenu enenensenenenennenn 18 Figure 3 5 Inband Remote Configuration eenennesenennennens 20 Figure 3 6 P
6. d at NI Loss of Signal No signal detected at NI 2nd GEN Nx56 64 V 35 Option Module Clock Slip Difference in frequency of the data clock at the network and DTE PLL Alarm Unable to lock phase lock on the clock provided by the network interface Zeros Alarm All Os data being sent to the network interface No EXT Clock No external transmit clock at DTE when applicable 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 25 Appendix A TSU HSU X00 System Messages STATUS MESSAGES Network Interface NI Payload On Payload loopback activated Line On Line loopback activated Loopback Off All loopbacks deactivated Factory Restore Factory setting restored Power On Unit powered on Self Test Internal self test performed 2nd GEN Nx56 64 V 35 Option Module Loop Up Data is looped back at both the network interface and the DTE interface of the card Remote Loop Up Sending a V 54 pattern in an attempt to loop up a remote device 511 Pattern On Sending a 511 pattern towards the network interface Loop Down Data is no longer looped back at the network interface or the DTE interface 511 Pattern Off No longer sending a 511 pattern towards the network interface 26 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Product Support Information Pre Sales Inquiries and Applications Support Please contact your local distributor ADTRAN Applica tions Engineering or ADTRAN Sales Applications En
7. dule User Manual 19 Chapter 3 Operation 20 9 INBAND Inband Configuration Channel Used to enable disable an 8 kbps remote configuration channel see Figure 3 5 When this option is set to ON the first DSO mapped to the Nx interface operates in 56K mode and the DTE clock rate is reduced by 8 kbps The TSU HSU uses this 8 kbps channel to send and receive configuration data across a Tl span As shown in Figure 3 5 this allows the PC connected to the chain in port on TSU 600 A to monitor configure both TSU 600 A and B This feature is useful when FDL connectivity is not available across the T1 span This 8 kbps channel is only taken out of the first DSO If two 64K DS0s are mapped the DTE rate would be 120 kbps instead of 128 kbps The menu option can also be set to On Demand which will activate the Inband Channel only when commands are sent from T Watch to the remote unit TSU 600 B in Figure 3 5 If no T Watch activity is detected for 10 minutes the Inband Channel is deactivated T WATCH TSU 600 A TSU 600 B CHAIN IN NX DSX 1 NX DSX 1 ROUTER PBX ROUTER PBX NOTE Figure 3 5 Inband Remote Configuration Although a router can accommodate this 8K rate reduction some DTE devices may not i e video Determination should be made if the connected DTE can handle this reduced clock source A second option would be to opera
8. e of the action required for proper placement of the option module Perform the following steps to install the option module 1 Remove the cover plate from the TSU HSU unit rear panel 2 Slide the option module into the rear panel of the TSU HSU unit until it is positioned firmly against the front of the unit 3 Fasten the thumbscrews at both edges of the option module j N N Cover Plate u a TSU HSU N UNIT N ff Option Module a Pa O O Figure 2 1 Installing the Option M odule Power Connection 8 2nd GEN Nx56 64 Option Module User Manual Each option module derives power from the base TSU HSU unit Power to the TSU HSU is supplied by a captive eight foot power cord 61202 054L1 1 Chapter 2 Installation Attaching the Plug On Board Figure 2 2 is representative of the action required for proper attachment of a plug on board to the option module Perform the following steps to install the plug on board 1 Hold the plug on board above the option module 2 Using a downward and right to left motion slip the V 35 Connector plug into opening in the option module back panel 3 Moving the plug on board downward secure the connection of the header pins at the front of the boards 4 Install the two 4 40 screws at both edges of the option module Figure 2 2 Attaching the Plug On Board The connection of the header pins bet
9. enus for the TSU 100 Menu items in the Main menu in Figure 3 1 printed in bold italics are submenu choices for 2nd GEN Nx56 64 V 35 option modules see Figure 3 2 Each submenu is discussed in the following paragraphs All are accessed by the same method With the cursor on one of the four Main menu choices press the Enter or number key The results are a display of the first two submenu items with the cursor on the first item Use the Scroll Down key to place the cursor on the desired item then press Enter This displays the first two submenu choices 61202 054L1 1 2nd GEN Nx56 64 MENU 61202 054L1 1 Chapter 3 Operation 1 DTE DATA CLOCK 1 STATUS 2 PORT STATUS 2 DTE STATUS 3 PORT RATE 1 INTERFACE 2 RATE Seon 7 PORT CONFIG 3 TX CKL CNTRL 4 DATA 8 0 INHIB 5 CTS 9 INBAND 7 PORT UTILITY SW REV LOOPBACK 4 TEST 1 i _f 3 PORT TEST 2 511 PATT 3 DISP 511 RSLT Figure 3 2 2nd GEN Nx56 64 V 35 Option Module Menu Tree 2nd GEN Nx56 64 Option Module User Manual 15 Chapter 3 Operation 2 PORT Status Submenu of 1 Status The Status menu branch provides the ability to view the status of the TSU 100 operation It displays the status of the monitored signal line on the 2nd GEN Nx56 64 V 35 option board and the data rate for which the option module is configured Operation To disp
10. gineering 800 615 1176 Sales 800 827 0807 Post Sale Support Please contact your local distributor first If your local distributor cannot help please contact ADTRAN Techni cal Support and have the unit serial number available Technical Support 800 726 8663 Repair and Return If ADTRAN Technical Support determines that a repair is needed Technical Support will coordinate with the Return Material Authorization RMA department to issue an RMA number For information regarding equipment currently in house or possible fees associated with repair contact RMA directly at the following number RMA Department 205 971 8722 Identify the RMA number clearly on the package below address and return to the following address ADTRAN Inc RMA Department 901 Explorer Boulevard Huntsville Alabama 35806 2807 RMA
11. he clock which should compensate for a long cable Choices Normal or Inverted 4 DATA Used to control the inverting of the DTE data This inversion can be useful when operating with a high level data link control HDLC protocol often used as a means to ensure ls density Choices Normal or Invert 18 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 3 Operation 5 CTS Used to control characteristics of CTS Choices Normal or Force On see Table 3 A 6 DCD Data Carrier Detect Indicates to the DTE when a valid signal is being received at the Network Interface Choices Normal or Force On see Table 3 A 7 DSR Data Set Ready This signal indicates to the DTE when the DCE is turned On and ready for operation Choices Normal or Force On see Table 3 A 8 0 INHIB If the Nx interface detects an uninterrupted string of Os being transmitted toward the network and if Os are transmitted for more than one second then the TSU 100 forces 1s towards the network Choices On or Off Table 3 A Normal Mode Operation conditions which cause the port control signal to be deactivated V 54 511TEST SELFTEST NETWORK NODSO NETWORK SIGNAL RTS LOOPBACK ON ACTIVE TESTACTIVE MAPPED ALARM CTS Follows Off Off Off Off Off Off DCD Off Off Off Off DSR Off Off Off Off Off Do not care Force On On under all conditions 61202 054L1 1 2nd GEN Nx56 64 Option Mo
12. ived data RD A to DTE Received data RD B to DTE RX clock RC A to DTE RX clock RC B to DTE Transmitted data TD A from DTE Transmitted data TD B from DTE TX clock TC A to DTE TX clock TC B to DTE External TX clock ETC A from DTE External TX clock ETC B from DTE Test mode TM to DTE Ignored by 2nd GEN Nx56 64 V 35 option module firmware revision F or higher 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 11 Chapter 2 Installation Power Up Testing and Initialization The option module executes a self test during the power up sequence as described in the TSU HSU manual No initialization input is required Upon power up any previously configured setting for the option module is automatically restored When the self testing is completed and the configuration is successfully restored the LED labeled OK in the MODULE group on the front panel turns On For more information see the section that discusses front panel operation in the Operation chapter of the appropriate TSU HSU user manual If any alarms are detected during operation the red LED labeled ALARM in the MODULE group on the front panel turns On 12 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 3 Operation OVERVIEW The 2nd GEN Nx56 64 V 35 option module is con trolled as part of the TSU HSU using the same methods as described in the appropriate TSU HSU user manual Front Panel Indicators B
13. lay Figure 3 3 on the TSU 100 starting with the cursor on Main menu item 1 STATUS do the following l Press the Enter or the number 1 key This displays the first two Status submenu items with the cursor on 1 NI PERF RPTS 2 Use the Scroll Down key to place the cursor on 5 PORT STATUS and press the Enter key This displays the first available port 3 Use the Scroll keys to identify 1 1 2nd GEN Nx56 64 V 35 and press the Enter key Figure 3 3 Port Status Submenu The Nx interface offers the status screens listed in this manual For other option modules refer to the appro priate manual 2ND GEN NX56 64 Status Select 0 1 2ND GEN NX56 64 1 DTE DATA CK 2 DTE STATUS 3 PORT RATE 16 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 3 Operation DTE Data CK Shows the status active or not active of the following lines TXD Transmit data from the DTE RXD Receive data toward the DTE ETC External transmit clock from DTE LCK Lock status of the phase locked loop DTE Status Shows the status active or not active of the following lines RTS Request to send from DTE CTS Clear to send to DTE DCD Data carrier detect to DTE DSR Data set ready to DTE Port Rate Displays the data rate to which the NX port is set Exit the displays as described in the TSU 100 User M anual 7 PORT CONFIG Submenu of 2 CONFIG The 7 PORT CONFIG submenu is used for configura tion of the 2nd GEN Nx56 6
14. ld be 1 1 and if a plug on V 35 is present port 1 2 In a TSU 600 with six option slots these port numbers would be port 1 1 to port 6 1 The numbers appear in the front panel LCD menu displays L i 2 Le 2 K NX 56 64 Ge esestens NX 56 64 PORT X 1 000000000 PORT X 2 HOT vss OOSS0000 vas J REPLACEABLE 1 1 Cutout for second V 35 connector 2 Screw receptacles for plug on board 3 Port X 2 header pins Figure 1 1 2nd GEN Nx56 64 V 35 Option Module 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 5 Chapter 1 Introduction 6 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 2 Installation UNPACK amp INSPECT Carefully inspect the option module or plug on board for any shipping damage If damage is suspected file a claim immediately with the carrier and then contact ADTRAN customer service If possible keep the original shipping container for use in shipping the option module or plug on board back for repair or for verifica tion of damage during shipment ADTRAN Shipments Include e The 2nd GEN Nx56 64 Module or 2nd GEN Nx56 64 Plug on Board e The user manual to be inserted into main TSU HSU user manual Customer Provides e DTE cable 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 7 Chapter 2 Installation INSTALLING THE OPTION MODULE Placement of the Option Module Figure 2 1 is representativ
15. oked locally or remotely V 54 Chapter 1 Introduction 2nd GEN Nx56 64 V 35 Option Module Specifications DTE Interface CCITT V 35 Synchronous Rates 56 kbps to 1 536 Mbps in 56K or 64K steps Clock Options Normal Inverted Tests Local Loopback Bilateral Menu activated Remote Loopback V 54 Menu activated Self Test Test Pattern 511 with errored seconds display and error inject capability Data Inversion Menu selectable ls Density Protection Force ls to network after one second of consecutive zeros from DTE On Off CTS DCD DSR Options Normal or Forced ON Connector Winchester V 35 female Inband Communication Channel Enabled Disabled or On Demand 4 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 1 Introduction Physical Description The 2nd GEN Nx56 64 V 35 option module plugs into the option slot in the rear of the TSU HSU family of products see Figure 1 1 The rear panel of the option module includes a plastic plug over a cutout for a second V 35 connector This allows a 2nd GEN Nx56 64 V 35 plug on board or any other plug on board to be added to the 2nd GEN Nx56 64 option module creating a multiport module The PORT X 1 and X 2 indication is linked to the port numbering philosophy of the TSU HSU product family The X represents the slot number into which the option module is plugged For the TSU 100 there is only one option slot Therefore the port designation wou
16. ort Utility Submentinecsni ionerne iaro nrt aa 21 Figure 3 7 Display of Port Name and Software Version 22 Figure 3 8 Port Test Submenu snari aaa A 23 List of Tables Table 2 A V 35 Winchester Pin Connection neenneneneenensennnen ll Table 3 A Normal Mode Operation conditions which cause the port control signal to be deactivated eeen en 19 ee u 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 1 Introduction SECOND GENERATION 2ND GEN NX56 64 V 35 OPTION MODULE OVERVIEW The Second Generation 2nd GEN Nx56 64 V 35 option module is one of the option modules available for use with the following ADTRAN equipment e TSU 100 part number 1200052L1 e TSU 600 part number 1200076L1 e TSU 120 part number 1200129L1 e HSU 100 part number 1200097L1 e HSU 600 part number 1200098L1 The 2nd GEN Nx56 64 V 35 option module installs in the option slot of the TSU HSU family of products and provides an additional synchronous V 35 interface port When used in these products this interface port allows an additional DTE to have access to the T1 service 2ND GEN NX56 64 V 35 PLUG ON BOARD OVERVIEW 61202 054L1 1 The operations of the 2nd GEN Nx56 64 V 35 option module described in this manual are also applicable for the 2nd GEN Nx56 64 V 35 plug on board Operation of both is identical except for the physical installation 2nd GEN Nx56 64 Option Module User Manual 1 Chapter 1 Int
17. roduction THE FUNCTIONAL DESCRIPTION OF THE 2ND GEN NX56 64 V 35 OPTION MODULE AND PLUG ON BOARD The 2nd GEN Nx56 64 V 35 option module operates in the option slot of the TSU HSU products while the plug on board operates as a plug on to any option module Both are under the control of the TSU HSU product The option module and the plug on board are config ured from the front panel or by an external PC program The internal menus for their configuration are part of the option module and plug on board and are automati cally installed when either is plugged into a TSU HSU product 2 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 1 Introduction FEATURES OF THE 2ND GEN NX56 64 V 35 OPTION MODULE Interfaces 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual Operates using 1 to 24 DSOs Includes an elastic store for absorption of rate variations Capable of including a Nx56 64 V 35 plug on interface port resulting in a dual port module Outputs a 50 percent duty cycle output clock at all rates Menu operation for easy configuration Executes and responds to V 54 looping codes Generates and checks a 511 test pattern Performs an extensive self test Supports multiport dial backup operation Provides inband channel network management communication CCITT V35 electrical differential Connector V 35 Winchester Loopbacks Port toward the network DTE toward the DTE Both loopbacks can be inv
18. tactivates both a local loopback back toward the DTE and a port loopback when either is invoked REMOTE The remote loopback causes a V 54 code to be sent to the far end The Nx at the far end activates a PORT LCL loopback on detection of the V 54 code OFF The loop is deactivated 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 23 Chapter 3 Operation The TSU HSU checks the remote loopback activation by detecting a proper response from the remote end While waiting for the response the display shows LOOPING If NOTE successful the display changes to LOOPED UP If unsuc cessful the display shows FAILED 2 511 PATT Activates the generation of the 511 test pattern ON The pattern check circuitry is enabled anda test started The test is ended by selecting OFF OFF The pattern generation and check is disabled 3 DIS 511 RESLT Displays the results of the 511 test indicated in 2 511 PATT The results are in the form of the number of errored seconds The error count can be cleared by pressing the Clear key Shift 9 A bit error may be inserted into the data stream by pressing the 2 key 24 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Appendix A TSU HSU X00 System Messages ALARM MESSAGES Network Interface NI Red Alarm NI unable to align frame with incoming signal Yellow Alarm Remote alarm indication RAI being received from the far end Blue Alarm Unframed all 1s AIS being receive
19. te in 56K DS0 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 Chapter 3 Operation 3 FACTORY RESTORE Submenu of 3 UTIL This selection is used to restore the factory default settings for all Passthru option module parameters Operation To return the unit to the opening Main menu with all the factory default settings restored do the following l Follow the standard operating procedure to access the 3 UTIL menu items 2 With the cursor on 3 FACT RESTORE press the Enter key 7 PORT UTILITY Submenu of 3 UTIL The 7 PORT UTILITY submenu is used primarily to display the current software information for each port installed in the unit This information is required when requesting assistance from ADTRAN Technical Support or when updates are needed Operation To display Figure 3 6 on the TSU 100 do the following l Follow the standard operating procedure to access the 3 UTIL menu items 2 With the cursor on 7 PORT UTILITY press the Enter key This displays the first available port Figure 3 6 Port Utility Submenu 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 21 Chapter 3 Operation To display the port name and the software version installed as shown in Figure 3 7 do the following 1 Use the Scroll keys to move through the available ports or enter the port number with the number key 2 When the desired port name is displayed press the Enter key Figure
20. uttons Menu Structure 61202 054L1 1 Refer to the description of the TSU HSU front panel indicators and buttons in the appropriate user manual The 2nd GEN Nx56 64 V 35 option module menus appear as a subset of and operate the same as menus for the TSU HSUs The menus are accessed by selecting 1 1 2nd GEN Nx56 64 under the PORT menu items The Main menu for the TSU 100 is used for illustrative purposes The Main menu for the other TSU HSU units operates in a similar way Figure 3 1 shows the TSU 100 Main menu with the PORT menu items printed in bold italics See the figure TSU 100 Menu Tree in the TSU 100 User Manual for a complete menu tree diagram 2nd GEN Nx56 64 Option Module User Manual 13 Chapter 3 Operation 1 NI PERF REPORTS 1 STATUS 2 NI ERRORS 1 NETWORK NI 3 ACTIVE ALARMS 2 UNIT 4 VIEW HISTORY 3 MAP XCHNG PORT STATI 2 CONFIG SPORT STATUS 4 MAP IN USE A B TSU 100 MAIN MENU S DSO MAP A 1 ENTER PASSCODE DSO MAP B 6 DS0 2 TIME DATE 7 PORT CONFI JPORTCONFIG 3 FACTORY RESTORE S UTIL 4 REINIT UNIT 5 UNIT ID 1 NETWORK TESTS 4 TEST 6 SOFTWARE REV 2 RUN SELF TEST 7 PORT UTIL 3 PORT TEST 4 CANCEL TEST Figure 3 1 TSU 100 Main Menu Tree 2nd GEN Nx56 64 V 35 Menus Are All Submenus Operation 14 2nd GEN Nx56 64 Option Module User Manual The 2nd GEN Nx56 64 V 35 option module menus are accessed from and operated the same as m
21. ween the option module v and the plug on board must be visually verified Severe damage of the equipment can result from an improper connection 61202 054L1 1 2nd GEN Nx56 64 Option Module User Manual 9 Chapter 2 Installation WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in service For detailed warranty repair and return information refer to the ADTRAN Equipment Warranty Repair and Return Policy Procedure Return Material Authorization RMA is required prior to returning equipment to ADTRAN For Service RMA requests or more information contact one of the numbers listed at the end of this manual 10 2nd GEN Nx56 64 Option Module User Manual 61202 054L1 1 WIRING Chapter 2 Installation The 2nd GEN Nx56 64 V 35 option module has a V 35 Winchester style connection as defined in Table 2 A Table 2 A V 35 Winchester Pin Connection PIN CCITT DESCRIPTION 101 102 105 106 107 109 104 104 115 115 103 103 114 114 113 113 Zzce2 lt uox lt rZr Inmune gt Protective ground PG Signal ground SG Request to send RTS from DTE Clear to send CTS to DTE Data set ready DSR to DTE Received line signal detector DCD to DTE Data terminal ready DTR from DTE Ring indicator RI Local loopback LL from DTE Remote loopback RL from DTE Rece