PAK-4 & PAK-4R - Air Systems International

image

Contents

1. Step 6 im i 8 a Optional y n Step 2 Step 7 Step 7 Optional OPERATION When the cylinder in use has been depleted to approximately 500psi 35 bar the low pressure warning alarm will sound indicating that the cylinder needs to be replaced To change a cylinder while the PORTA PAK is still in use 1 Index the selector valve to the second cylinder and note the gauge pressure to assure that it is full 2 Close the drained cylinder and open the corresponding bleeder valve to relieve pressure on the hand tight nut 3 Install a known full cylinder in its place and connect CGA 347 hand tight nut to cylinder valve Close the bleeder valve on the connect whip and open the cylinder It is now ready for use when the other cylinder s pressure descends to 500psi SHUTDOWN Make sure all personnel have egressed the hazardous area and have disconnected from the breathing air system 1 Close cylinder valves 2 Depressurize manifold pressure by pulling the relief valve ring 3 Open bleeder valves 4 Close the regulator by turning the control knob counterclockwise 5 Reinstall dust caps 6 Remove connections from cylinders Reinstall cylinder valve covers if applicable HIGH PRESSURE AIRLINE GENERAL MAINTENANCE amp INSPECTION M
2. Bleeder Valves before cylinder removal Allows independent cylinder operation and removal without complete system shut Check Valves down Warning Aarme esha Warning Alarm set at approximately 500psi 34 5 bar Pressure 0 125psi 8 6 bar discharge Flow Rate discharge pressure Pressure 0 125psi 8 6 bar discharge Secondary Regulator 24cfm 678 LPM 65psi 4 5 bar discharge pressure Scfm 141 LPM 80psi 5 5 bar discharge pressure Intrinsically Safe 3 Parts IDENTIFICATION e aid i PART RELIEF VALVE VR4125BR cosce GA20160B arn ar ac CGA 347 PRESSURE CAP SS347CAP CGA 347 MALE ADAPTER SS4F347AM Saamen e VC4MMSS AC PA25 sg CYLINDER PRESSURE GAUGE GA206KB 9 CGA 347 HANDTIGHT NUT NIPPLE SS347HT REG 5000 Il NYLON CYLINDER STRAP HDWRI13A HANSEN RESPIRATOR FITTING QDH3SL6M SCHRADER RESPIRATOR FITTING QDSSL6M QDH3DCAP QDSDCAP VALI53 WLO13 GA 15160B QDH3SLAM 18 8 WHEEL HDWRI100 19 HOSE RACK COVER PIN HDWRI14 HANDLE PORTA PAK PIN HDWR130 4 SETUP PROCEDURE Step 1 Install cylinders on PORTA PAK tray Secure cylinders by tightening the straps at the buckle and mate the velcro sections to prevent slipping 2216psi 153 bar or 4500psi 310 bar cylinders can be used Step 2 Install CGA 347 hand tight nuts to the cylinder valves and tighten Insure both bleeder valves are closed by turning fully clockwise Step 3 Open one cylinder Step 4
3. Index the selector valve so that it points to the open cylinder At this time the low pressure warn ing alarm will sound until it sets itself at approximately 1000psi 69 bar Check reading on gauge to verify that it is full Close the cylinder Step 5 Set the required respirator pressure with the regulator control knob and bleed pressure at either the relief valve or by partially engaging a male plug into one of the respirator couplings This depressurizes the manifold and simulates low cylinder pressure The low pressure warning alarm should sound at approximately 500psi 35 bar Step 6 Index the selector valve toward the other cylinder and open At this time the low pressure warn ing alarm will resound until it sets itself at approximately 1000psi 69 bar Check reading on gauge to verify that it is full When both cylinders are known to be full reopen the first one tested Optional Install high pressure connect whip to auxiliary inlet port CGA 347 This step can be done after Step 6 or at anytime during operation of the system Step 7 Couple respirators and lengths of hoses to the manifold and readjust pressure regulator if neces sary The system is now operational Optional If pneumatic equipment is to be used which requires a different pressure than the respirators set the secondary low pressure regulator accordingly Locking regulator push to lock pull to unlock
4. ING OUT OF DEFECTS IN OR FAILURE OF THE PRODUCT OR ANY PART THEREOF The purchaser shall be solely responsible for compliance with all applicable Federal State and Local OSHA and or MSHA requirements Although Air Systems Interna tional believes that its products if operated and maintained as shipped from the factory and in accordance with our operations manual conform to OSHA and or MSHA requirements there are no implied or expressed warranties of such compli ance extending beyond the limited warranty described herein Product designs and specifications are subject to change without notice Rev 2 12 98
5. Models PAK 4 amp PAK 4R Manual No PAK002 Rev 6 February 1999 AR INTERNATIONAL Operating Manual AN S a L umm AIRSYSTEMS INTERNATIONAL INC 829 Juniper Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems cc e mail sales airsystems cc Regisered ta ma fo Mia Copyright Air Systems International Inc 2000 All Rights Reserved 2 OVERVIEW The PORTA PAK series has been designed as a multifunctional rapid response portable bottled air unit It allows four 4 workers to plug in airline respirators to a portable bottled air distribu tion system The system will accommodate most SCBA cylinders with 2216psi and 4500psi simultaneous capability Common applications include confined space entry Hazmat tactical rescue emergency response or any other breathing air applications where the size of a cart is of concern for either entry storage or portability The additional low pressure regulator and port permits the use of pneumatic equipment such as saws chisels and lift bags or an additional respi rator SPECIFICATIONS ati 29 5 Lx21 W x6 5 D PAK 4 Tray Size 75cm H x 53cm x 17cm D pe 26 W x33 Hx16 1 4 D Cart Dims 66cm W x 84cmH x 41 5cm D Frame sd Ramat Aluminum powder coat painted coat painted Cylinder Straps different size cylinders ip ascnti syle n Da Whip Assemblies safety factor pier Vanes a
6. onthly 1 Check regulators gauges and valves for external leakage 2 Inspect cylinder valves for proper closure 3 Check cylinder pigtails for cleanliness flexibility wear leakage blisters on hose thread damage and O rings on CGA fittings Replace damaged items immediately Annually 1 Check relief valve s pressure setting 2 Check regulator function by opening and closing regulator valve fully Every 4 years 1 Replace all flexible pigtails contact ASI customer service department 7 Warranty Disclaimer Air Systems manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for one year after date of purchase Any part which is determined by Air Systems to be defective in material or workman ship will be as the exclusive remedy repaired or replaced at Air Systems option This warranty does not apply to electrical systems or electronic components Electri cal parts are warranted to the original user for 90 days from the date of sale During the warranty period electrical components will be repaired or replaced at Air Sys tems option NO OTHER WARRANTY EXPRESSED OR IMPLIED AS TO DESCRIP TION QUALITY MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HEREWITH UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR LOSS OF PROFITS ANY OTHER DIRECT OR INDIRECT COSTS EXPENSES LOSSES OR DAMAGES ARIS