I/O ETHERNET CONTROLLER

image

Contents

1. 2 1 First time connection 2 2 Web interface 2 2 1 General 2 2 2 SNMP 2 2 3 Inputs 2 2 4 Outputs 2 2 5 Monitoring 2 2 6 Support F 2 3 SNMP EnaA be 2 3 1 General 2 3 2 SNMP 2 3 3 Inputs 2 3 4 Outputs a ANOEIE ne A te 9 ENT aele ae E A 10 3 1 Restoring to default parameters 3 2 Checking the firmware version a 3 3 FinMWareUpOraGde nn mn ee This document describes 1 0 Ethernet Controller ELAN1 based on SNMP protocol it s installation and operation It is very important to read User Manual before start using the system 1 General Information 1 1 Function ELANT is a micro controller based device used to inform users about the state changes on digital or analog inputs and control one electric appliance open collector All these features can be configured via Web interface or SNMPv1 protocol 1 2 Operation description Monitoring and control system ELAN1 uses Ethernet Network for transmission of inputs traps generated by one of the inputs to Network Monitoring Systems NMS In addition to being informed about triggers resets of the inputs user can manage the system and use it to control one electronic device The system has 4 inputs which can be set to operate in Digital Analog mode or swtiched off Off mode By connecting an electronic device to ELAN1 open collector output user can control 1 electronic device on receipt of the correct SNMP set command with correct community string or cha
2. I O ETHERNET CONTROLLER Manual v1 0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around SE E Copyrigl It is not Ii PP Pee Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system System label is on the bottom side of the device System ELAN1 is a device mounted in limited access areas Any system repairs must be done only by qualified safety aware personnel The system must be powered by main 10 24V 120mA max 10 24V 50Hz 120mA max power supply which must be approved by LST EN 60950 1 standard and be easily accessible External power supply must be reachable and can be connected to AC mains only inside installation room with automatic 2 pole circuit brea ker capable of disconnecting circuit in the event of short circuit or over ei y PE current condition Open circuit breaker must have a gap between con nections of more than 3mm SS AC 230V 50 Hz DC 24V ELAN1 USB cable Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The device is switched off by 2 pole circuit breaker Fuse F1 type miniSMDC 0 5A Replacement fuses have to be exactly the same as indicated by the manufact
3. output deactivated Output control 1 3 6 1 4 1 34093 1 2 200 1 0 read write 0 1 1 ON output activated 2 3 5 Monitoring Parameter name OID Access Value Example comment Input1 montoring status 1 3 6 1 4 1 34093 1 2 300 1 0 read 0 1 Na 0 input is restored 1 input is triggered Na not available Input2 montoring status 1 3 6 1 4 1 34093 1 2 300 2 0 read 0 1 Na 0 input is restored 1 input is triggered Na not available Input3 montoring status 1 3 6 1 4 1 34093 1 2 300 3 0 read 0 1 Na 0 input is restored 1 input is triggered Na not available Input4 montoring status 1 3 6 1 4 1 34093 1 2 300 4 0 read 0 1 Na 0 input is restored 1 input is triggered Na not available Input1 montoring value 1 3 6 1 4 1 34093 1 2 301 1 0 read 1 10000 Na i e 6000 mV Na not available Input2 montoring value 1 3 6 1 4 1 34093 1 2 301 2 0 read 1 10000 Na i e 6000 mV Na not available Input3 montoring value 1 3 6 1 4 1 34093 1 2 301 3 0 read 1 10000 Na i e 6000 mV Na not available Input4 montoring value 1 3 6 1 4 1 34093 1 2 301 4 0 read 1 10000 Na i e 6000 mV Na not available If the problem persists and it cannot be fixed by the self guide above please contact your distributor or ELDES technical support by e mail support eldes lt More up to date information about your device and other products can be found at the manufacturer s website
4. 1 3 6 1 4 1 34093 1 2 60 3 0 read write text 16 chars max i e Input 3 Input4 name 1 3 6 1 4 1 34093 1 2 60 4 0 read write text 16 chars max i e Input 4 Input1 state ON name 1 3 6 1 4 1 34093 1 2 61 1 0 read write text 16 chars max i e Input 1 is ON Input2 state ON name 1 3 6 1 4 1 34093 1 2 61 2 0 read write text 16 chars max i e Input 2 is ON Input3 state ON name 1 3 6 1 4 1 34093 1 2 61 3 0 read write text 16 chars max i e Input 3 is ON Input4 state ON name 1 3 6 1 4 1 34093 1 2 61 4 0 read write text 16 chars max i e Input 4 is ON Input1 state OFF name 1 3 6 1 4 1 34093 1 2 62 1 0 read write text 16 chars max i e Input 1 is OFF Input2 state OFF name 1 3 6 1 4 1 34093 1 2 62 2 0 read write text 16 chars max i e Input 2 is OFF Input3 state OFF name 1 3 6 1 4 1 34093 1 2 62 3 0 read write text 16 chars max i e Input 3 is OFF Input4 state OFF name 1 3 6 1 4 1 34093 1 2 62 4 0 read write text 16 chars max i e Input 4 is OFF Input priority 1 3 6 1 4 1 34093 1 2 63 1 0 read write 1 8 ie 2 Input2 priority 1 3 6 1 4 1 34093 1 2 63 2 0 read write 1 8 i e 3 Parameter name Access l E Example comment Input3 priority 1 3 6 1 4 1 34093 1 2 63 3 0 read write 1 8 i e 8 Input4 priority 1 3 6 1 4 1 34093 1 2 63 4 0 read write 1 8 i e 1 Input1 mode 1 3 6 1 4 1 34093 1 2 6
5. 34093 1 2 11 3 0 read write number i e 80 Firmware version 1 3 6 1 4 1 34093 1 2 12 1 0 read number i e 80 2 3 2 SNMP Settings Parameter name on Access Value Example comment nus A i e Inputs monitoring SysDescription 1 3 6 1 2 1 1 1 0 read write text 32 chars max SNMP device SysObjectID 1 3 6 1 2 1 1 2 0 read 1 3 6 1 4 1 34093 1 2 constant SysUpTime 1 3 6 1 2 1 1 3 0 read counter i e 10778 seconds A i e ELDES Tel No SysContact 1 3 6 1 2 1 1 4 0 read write text 32 chars max 4370111111 SysName 1 3 6 1 2 1 1 5 0 read write text 32 chars max i e ELAN1 device SysLocation 1 3 6 1 2 1 1 6 0 read write text 32 chars max i e Vilnius Lithuania Read Community 1 3 6 1 4 1 34093 1 2 30 1 0 read write text 16 chars max i e public Write Community 1 3 6 1 4 1 34093 1 2 30 2 0 read write text 16 chars max i e private Trap Destination1 1 3 6 1 4 1 34093 1 2 31 1 0 read write IP address i e 192 168 1 201 Trap Destination2 1 3 6 1 4 1 34093 1 2 31 2 0 read write IP address i e 192 168 1 202 Trap Destination3 1 3 6 1 4 1 34093 1 2 31 3 0 read write IP address i e 192 168 1 203 2 3 3 Inputs Settings Parameter name Example comment Input1 name 1 3 6 1 4 1 34093 1 2 60 1 0 read write text 16 chars max i e Input 1 Input2 name 1 3 6 1 4 1 34093 1 2 60 2 0 read write text 16 chars max i e Input 2 Input3 name
6. browser When connecting first time please ensure that the IP address of the PC has the same subnet as ELAN1 device By default the IP address of ELAN1 is 192 168 1 101 In order to make an Ethernet connection please set the TCP IP settings of PC as follows IP address 192 168 1 105 Subnet mask 255 255 255 0 Gateway 192 168 1 1 DNS1 blank DNS2 blank After configuring the TCP IP settings please put the address in URL field as http 192 168 1 101 and hit Enter User will be prompted to enter user name and password The default user name and password are 1234 After successful log in process user can configure ELAN1 device as needed The connection session closes after 5 minutes of inactivity 2 2 Web interface After successful access to ELAN1 device via Web browser you will see 6 main menu sections General SNMP Inputs Outputs Monitoring Support All these menu sections are described in detail below 2 2 1 General In General configuration menu section users can configure these parameter groups Ethernet configuration IP IP address of ELAN1 Default IP address is 192 168 1 101 Mask subnet mask of ELAN1 Default subnet mask is 255 255 255 0 Gateway gateway of ELAN1 Default gateway is 192 168 1 1 Web server configuration Username user name for authorization to log in to configuration web interface Default user name is 1234 Password password for authorization to log in to configuration web interf
7. upgraded BO MNANAWHD Copyright ELDES UAB 2011 All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this ELAN1 device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt
8. www eldes lt USER MANUAL ELAN1 V1 0 3 Appendix 3 1 Restoring to default parameters In order to restore the default device parameters please carefully follow these steps 1 Disconnect the power supply Disconnect the USB cable Short circuit connect the two DEF connectors see section 1 3 Connectors and main unit description Power up the device and wait for 5 seconds Disconnect the power supply Remove the short circuit Power up the device Default parameters restored SONAUPRWN 3 2 Checking the firmware version In order to find out the current running device firmware version please log in to ELAN1 Web configuration interface After su ccessful log in process the firmware version will be indicated in the upper part of Web interface In order to find out the firmware version via SNMP please refer to section 2 3 1 General Settings 3 3 Firmware upgrade The following steps describes ELAN1 firmware upgrade procedure Please follow them carefully 1 Disconnect the power supply Connect the device to the PC using USB cable Short circuit connect the two DEF connectors see section 1 3 Connectors and main unit description Power up the device After the new window pops up replace the existing bin firmware file with a new firmware bin file After firmware file replacement please disconnect the power supply Unplug the USB cable from the device Remove the short circuit Power up the device 0 ELAN1 firmware
9. 4 1 0 read write 0 1 2 0 Digital 1 Analog 2 Off Input2 mode 1 3 6 1 4 1 34093 1 2 64 2 0 read write 0 1 2 0 Digital 1 Analog 2 Off Input3 mode 1 3 6 1 4 1 34093 1 2 64 3 0 read write 0 1 2 0 Digital 1 Analog 2 Off Input4 mode 1 3 6 1 4 1 34093 1 2 64 4 0 read write 0 1 2 0 Digital 1 Analog 2 Off Digital Input type 1 3 6 1 4 1 34093 1 2 65 1 0 read write 0 1 X a Digital Input2 type 1 3 6 1 4 1 34093 1 2 65 2 0 read write 0 1 i e ne Digital Input3 type 1 3 6 1 4 1 34093 1 2 65 3 0 read write 0 1 j N ple ae ea Digital Input4 type 1 3 6 1 4 1 34093 1 2 65 4 0 read write 0 1 o E Digital Input1 threshold 1 3 6 1 4 1 34093 1 2 66 1 0 read write 1 10000 i e 6000 mV Digital Input2 threshold 1 3 6 1 4 1 34093 1 2 66 2 0 read write 1 10000 i e 5000mV Digital Input3 threshold 1 3 6 1 4 1 34093 1 2 66 3 0 read write 1 10000 i e 2000mV Digital Input4 threshold 1 3 6 1 4 1 34093 1 2 66 4 0 read write 1 10000 i e 4000mV Analolg Input delta 1 3 6 1 4 1 34093 1 2 67 1 0 read write 1 10000 i e 200 mV Analolg Input2 delta 1 3 6 1 4 1 34093 1 2 67 2 0 read write 1 10000 i e 300 mV Analolg Input3 delta 1 3 6 1 4 1 34093 1 2 67 3 0 read write 1 10000 i e 250 mV Analolg Input4 delta 1 3 6 1 4 1 34093 1 2 67 4 0 read write 1 10000 i e 360 mV 2 3 4 Outputs Settings Value Parameter name eo p Example comment 0 OFF
10. ace Default password is 1234 Local Port local TCP port of ELAN1 Default port is 80 2 2 2 SNMP In SNMP configuration menu users can configure these parameters Read Community password for authorization to read SNMP parameters from ELAN1 Default read community is public Write Community password for authorization to write SNMP parameters to ELAN1 Default write community is private e SysDescription general description of ELAN1 device ex Inputs monitoring via SNMP device SysContact the name of person or company whom user can contact if support needed SysName general name of device ex ELAN1 e SysLocation the name of location where ELAN1 device is installed Trap destination IP address of 1st trap destination Trap destination2 IP address of 2nd trap destination Trap destination3 IP address of 3rd trap destination 2 2 3 Inputs When users access Inputs configuration menu section they can configure these parameters for all available ELAN1 inputs General Settings Mode switch between 3 available input modes Analog Digital Off and assign the selected mode to any available system input Digital Mode Settings Type switch between 2 available digital input modes No normally open Nc normally closed and assign the selected mode to the respective digital input In No mode input is triggered when input voltage runs below the set threshold value input is restored when t
11. et port yes Number of inputs 4 Allowable input voltage values 0 10 V DC Number of outputs 1 Output maximum switching ratings Current 500mA voltage 30V Output circuit Open collector output Output is pulled to COM when enabled Se Le OUT A Status LEDs 2 b Dimensions 86x53x23mm Operating temperature range 30 55 C 1 5 LED indications PWR Status green LED Description OUT Status red LED Description Flashing once per second ELANT is operating successfully Lighting continuously Output is activated Lighting continuously Firmware or hardware failure Switched Off Switched Off 1 6 Powering ELAN1 device Power supply failure Output is deactivated ELAN1 device must be powered from the voltages of 10 24V AC DC After successful power feed the power PWR LED green is flashing and ELAN1 generates SNMP cold start 0 trap with one variable SysLocation In case of power failure or firmware malfunction PWR LED is switched off or lighting continuously USER MANUAL ELAN1 V1 0 2 Configuration 2 1 First time connection To start configuring the ELAN1 device it is necessary to make an Ethernet connection first When connecting ELAN1 directly to the PC please use a crossover Ethernet cable any other connections can be made by using straight through cables After making physical connection and powering the device please use the standard Web
12. he set threshold value is exceeded In Nc mode input is triggered when the set threshold value is exceeded input is restored when input voltage runs below the set threshold value In Off mode the respective input is disabled Threshold set the voltage value mV boundary for respective input trigger and restore state detection Default threshold value is 5000 mV Analog Mode Settings Delta set the value of voltage mV change When the voltage increases or decreases by the set delta value ELAN1 transmits the trap data packet indicating the voltage of the respective input Default delta value is 1000 mV in Off mode the respective input is disabled SNMP Settings Input Name title of the input which will be indicated in trap data packets State ON name title of the input s ON state which will be indicated in trap data packets State OFF name title of the input s OFF state which will be indicated in trap data packets Priority priority level for setting unique identification of trap data packets related to particular input User can set priority level from 1 to 8 2 2 4 Outputs The output state can be set to ON or OFF state by selecting it from the drop down list and pressing Write to device button During ON state output transistor is activated OUT1 pin is connected to COM pin and OUT LED is illuminated indicating that Output is activated During OFF state output transistor is deactivated OUT1 pin disconnected fro
13. m COM pin and OUT LED is switched off indicating that Output1 is deactivated 2 2 5 Monitoring In this section user can view and monitor every system input The page is automatically refreshed every 5 seconds Status indicates the status of respective digital input Values 0 input restored 1 input triggered Na not available Value indicates the voltage value mV of respective analog input Values 1 10000 mV Na not available 2 2 6 Support In case you need any assistance please call us 370 526 35437 You may also try to find helpful information on our website www eldes lt USER MANUAL ELANT V1 0 2 3 SNMP parameters table The table provided below describes the parameters OIDs action available for each parameter which can be configured via SNMP value and an example or comment for each parameter 2 3 1 General Settings Parameter name Access Example comment Ethernet config IP address 1 3 6 1 4 1 34093 1 2 10 1 0 read write IP address i e 192 168 1 101 Ethernet config subnet mask 1 3 6 1 4 1 34093 1 2 10 2 0 read write subnet IP i e 255 255 255 0 Ethernet config gateway 1 3 6 1 4 1 34093 1 2 10 3 0 read write gateway IP i e 192 168 1 1 Web server config username 1 3 6 1 4 1 34093 1 2 11 1 0 read write eh ae i e user Web server config password 1 3 6 1 4 1 34093 1 2 11 2 0 read write a ae i e psw1234 Web server config local port 1 3 6 1 4 1
14. nge the output state via Web interface For example turn on or off the heating lighting lift the gates blinds etc The system remembers the output setting in case of electricity failure Once initialized ELAN1 will function 24 7 When there is a change on any of inputs ELAN1 generates SNMP Enterprise specific 6 trap with the following sequence of 4 variables SysLocation Input name Input state name Priority 1 3 Connectors and main unit description Short explanation of the main units LAN OUT PWR LAN Ethernet RJ 45 port USB Mini USB port OUT Output ON OFF red LED indicator PWR Power green LED indicator DEF Connectors for restoring default settings INT IN4 Inputs 1 4 COM For connecting common pins of inputs OUT1 Output 1 AC DC Power supply pins LAN Ethernet RJ 45 port USB Mini USB port x PWR Power GREEN LED indicator OUT Output ON OFF RED LED indicator oo PWR OUT USB Terminal block connector layout 1 4 Technical Specifications Power supply voltage IN1 Input1 COM For connecting Input1 and Input2 common pin IN2 Input2 IN3 Input3 COM For connecting Input3 and Input4 common pin IN4 Input4 OUT1 Output1 COM For connecting controlled device common pin AC DC Power supply pins AC DC Power supply pins 10 24V 120mA max 10 24V 50Hz 120mA max 10 100BaseT Ethern
15. t the system will re duce the risk of fire theft burglary or other dan gers but does not guarantee against such events ELDES UAB will not take any responsibility re garding personal or property or revenue loss while using the system ELDES UAB liability according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with any of the Inter net providers therefore is not responsible for the quality of Internet service Manufacturer Warranty This device carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the sys tem has been used as intended following all gui delines listed in the manual and within specified operating conditions Receipt must be kept as a proof of purchase date The warranty is voided if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environ ment or other force majeure factors Package content TELAN sens qty 1 2 ELAN1 User Manual qty 1 About User Manual CONTENT 1 General information lt ccccscccocsescoceccescnccseceascaccsacccsescasassetescerascoraccetes 4 TARTO e mme mm m 4 1 2 Operation description 1 3 Connectors and main unit deep 1 4 Technical Specifications 1 5 LED indications A N6 Powering ELANTAEViCE rm 5 PAU e E E A E A PR Le dense Een 6
16. urer Any additional devices linked to the system ELAN1 computer sensors relays etc must be approved by LST EN 60950 1 standard The device is fully turned off by disconnecting 2 pole switch off device of the external power supply or any other linked device that the system ELAN1 is powered from If you use security class computer for setting the parameters it must be connected to earth The WEEE Waste Electrical and Electronic Equipment marking on this product see right or its documentation indicates that the pro duct must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the system supplier or the local authority responsible for waste disposal in your area ht ELDES UAB 2011 All rights reserved allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this ELAN1 device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt Limited Liability The buyer must agree tha