1. CH8 Up Down Move 129 191 Manual Up Down Moving 192 223 Auto to Up Moving 224 255 Auto to Down Moving 0 15 No rolling CH9 Left Right 16 31 Left Right Rolling Rolling 32 239 Manual Left Right Rolling 240 255 Auto Rolling 0 15 No Rolling CH10 Up Down 16 31 Up Down Rolling Rolling 32 239 Manual Left Right Rolling 240 255 Auto Rolling Maintenance Maintenance should be performed every 15 day period by using a sponge which is dipped with alcohol rather than wet cloth or other chemical liquid to clean the mirror Always disconnect from the mains when the device is not in use or before cleaning it Warning Power must be disconnected before maintenance or repair Do not look at the light source directly Note Don t separate laser machine from laser power and repair them by yourself otherwise no good repair service will be supplied Technical Specifications 1 Power Supply AC 220 240V AC 100 120V 2 Rated Power 30mW 3 Working Mode Sound Active Auto play DMX512 Master Slave 4 Control Signal DMX512 signal 5 DMX Control Channels 10channels 6 Operating Temperature 1 35 7 Storage Temperature 10 60 8 Warm Up Time lt 15 min 9 Laser Classification 3b 10 Modulation TTL Declaration This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and
2. Laser Show System User s Manual Green Laser Light Model BI 2006 Please read this manual carefully before use Thank you for purchasing this product Please read user guide for safety and operations before using Keep this manual for future reference This product can create perfect laser programs and effects since it has passed a series of strict test before delivery Once after received this product please take and put carefully And check cautiously that whether the product was damaged or not during the transportation Checking Parts Please check if the following parts are included 1 x Laser Light 1 x Power cable 1 x User manual Danger Laser Radiation Avoid direct eye exposure Laser radiation can cause eye damage or skin damage All protective measures for a safe operation of this laser must be applied Attention 1 Must operate according to the user manual Don t separate the light personally Call the technician when the machine breaks down 2 Please do not see the laser beam directly to avoid any damage 3 Before connect or disconnect the power please adjust the luminance of the laser diode to the least to avoid any damage to the laser diode 4 This unit should be keep dry do not use in the rain and dusty environment It can be use in the outdoor with the water proof cover protector 5 Set the light immobility and try to avoid strong shake or hit 6 Prevent dust into the equipment to avoid problems 7
3. Please keep that there s no other equipment or decorating materials obstructed the exhaust fan and the vent pipe when the equipment was working 8 Before connect power check the plug is immobility or not power line should be connect well 9 Please do not open or close the equipment frequently that s to avoid any affect to the life span of the laser diode and try the best to avoid the long time working 10 Due to the characteristic of the laser diode after four hours working it should be close at least 25 minutes until the laser diode cooling then work again 11 Don t touch the light or draw the power line when your hand was wet And do not pull the electronic power line 12 Maintain the distance at least 10M above from the equipment to the object 13 This equipment does not have any parts can repair for the users please do not open the equipment 14 When the laser diode became dim or damaged please contact the dealer timely 15 To use the original package when transport again and to avoid shake Function Instructions 1 If you put dip switch 10 to on the light will be in auto play mode 2 When you turn off all the dip switches the light will be in sound active mode 3 Principal and subordinate light setting in Auto run mode when the principal light is switched to code 10 the light will run the settled program automatically meanwhile with the output of DMX512 signal After switching to dip switch 10 you can control t
4. he running speed by turning on dip switch1 9 Just one light could be settled to be principal machine Setting subordinate Dip switch 1 9 could be settled according to address code and dip switch 10 is turned off 4 Principal and subordinate light setting in Sound active mode when every dip switches are turned off the light is in sound active mode In this condition the light will run program along with music meanwhile with the output of DMX512 signal Just one light could be settled to be principal machine Setting subordinate Dip switch 1 9 could be settled according to address code and dip switch 10 is turned off Channel Instruction 0 15 Close Light Mode 16 127 Open Strobe CH1 128 239 Close Strobe 240 255 Open Light CH2 Function Speed 0 255 From Slow to Fast CH3 Select Patterns 0 253 128 gobos 0 63 Dot clearness CH4 Drawing 64 191 Drawing 192 255 Auto Drawing 0 Original Size CH5 Pattern 1 128 Manual reducing Reducing 129 255 Auto Reducing 0 15 0 degrees 32 47 Rotate 180 degrees Srey oranan 48 63 Rotate 270degrees 64 223 Auto Rotation 224 239 Auto Clockwise Rotation 240 255 Auto Counter Clockwise Rotation 0 128 Left Right Position 129 159 Left Move CH7 Left Right Move 160 191 Right Move 192 223 Auto to Left moving 224 255 Auto to Right moving 0 128 Up Down Position
5. warning notes written in this user manual We cannot be made liable for damages caused by incorrect installations and unskilled operation