Home

AxTraxNG™ Software Installation and User Manual

image

Contents

1. In the Description field enter a name for the access area 5 Select and move the desired readers from Available Readers to Enter to Selected Readers to Enter using the arrows 6 Select and move the desired readers from Available Readers to Exit to Selected Readers to Exit using the arrows 7 Click OK The window closes and the new access areas appear in the Display Area 5 15 Adding Global Antipassback Rules Global antipassback functionality is only enforced when the AxTraxNG Server is connected and monitoring the entire access control system To create antipassback rules 1 In the Tree View select Global Antipassback 2 On the toolbar click the F icon The Add Global Antipassback window opens 78 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Global Antipassback Description Access Area Access Area 1 7 w Automatic Antipassback Hever ka Hard alarm and access denied Soft alarm only 3 In the Description field enter a name for the antipassback rule From the Access Area dropdown select the access area 5 From the Automatic Antipassback dropdown select the time zone for which the global antipassback applies 6 Select either the Hard or the Soft Antipassback option 7 Click OK The window closes and the global antipassback rule appears in the Display Area Global Antipassback applies an Antipassback event only on
2. 3 Select the users from the available list for whom you wish to print a card and move them to the right panel 4 Click Next The Print Card Preview screen opens AxTraxNG Software Installation and User Manual 101 Card Design Photo ID Print Card Use camera 5 Set up the barcode a Right click on the Barcode field and select Clipboard Fort Background Transparent Lett Align Center Right Align Clipboard i Edit Delete b The Barcode Parameters window opens 102 AxTraxNG Software Installation and User Manual Card Design Photo ID SECURITY PRODUCTS Bar code parameters c Enter the numeric barcode d From the Alphabet coding dropdown select the kind of coding Bar code parameters Alphabet coding choose CODE128 CODE1Z8 CODE 284 CODE128B CODE 2Z8C CODES9 CODESSFULLASCI CODES DATAMATR DS DATAMATRICAS Cll DATAMATRIMBASE 25h e Click OK The barcode appears on the card template 6 Click Use camera if you wish to choose a different image either trom a file or from a PC camera The Se ect Source window opens Select source Graphic File PC Camera AxTraxNG Software Installation and User Manual 103 Card Design Photo ID a Doone ot the following 5 Select Browse to locate an image to insert 1 Select PC Camera and select Capture Image b Click OK 7 Use the green arrows to preview a
3. p The AxTraxNG Server and SQL Server databases must be installed on the same PC Note c For database servers installed from the AxTraxNG Server setup program SQL Server express add the instance name VeriTrax to the database computer name and click OK You return to the previous window 24 AxTraxNG Software Installation and User Manual l n sta ati O n SECURITY PROD CTS 7 In Connect using choose Server authentication using the Login ID and password below The only condition for choosing the Windows authentication credentials F of current user option is that you are using an existing SQL database ihe installed using Windows authentication only and not from the VeriTrax Setup 8 Click Next The Ready to Install the Program screen opens 9 Click Install The nstalling AxTraxNG Server screen opens ie AxTraxNG Server InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard When the installation is complete the nsta Shield Wizard Completed screen opens 10 Click Finish to complete installing the AxTraxNG Server software 3 6 Installing AxTraxNG Watchdog Once the AxTraxNG server installation finishes the AxTraxNG Watchdog installation opens automatically If you are up
4. Hardware Profile Service Profile 1 Enabled Disable 4 In the Log On tab verify that the Local System Account radio button is selected If not select Local System Account and restart the computer for the changes to take effect AxTraxNG Software Installation and User Manual 133 Network Configuration C Network Configuration The AxTraxNG Server connects to access control units by a serial connection a TCP IP connection or a Modem to Modem connection To connect access control panels to AxTraxNG over a TCP IP LAN Local Area Network or WAN Wide Area Network the use of a TCP IP to Serial converter is required unless the panel has an onboard TCP IP connection AC 225IP or AC 525 Each TCP IP connection can support up to 32 access control panels that are connected to each other using RS 485 The hardware used to connect to the TCP IP network may be the MD N32 which is a Serial to Ethernet converter or using the onboard converter of AC 225IP or AC 525 You can also use Rosslare s MD N33 modem for a Modem to Modem connection Refer to the hardware installation manuals of the desired panel for more details TCP IP and Modem to Modem connections must be configured for use and require expert knowledge of the local network To configure TCP IP Connection for AxTraxNG 1 In the Tree View click AC Networks 2 On the toolbar click the icon 3 The Networks window opens 4 Set the Net
5. Pick a category Appearance and Themes Printers and Other Hardware e a Network and Internet Connections v User Accounts Date Time Language and Regional Add or Remove Programs 8 Dpti A y Sounds Speech and Audio Devices Accessibility Options t J Security Center 2 Click the Security Center category The Windows Security Center window opens When in Classic View click the Security Center category in the top left Control Panel preferences pane J Windows Security Center CoR wy Security Center Help protect your PC Security essentials Get the latest security and virus information from Microsoft Check for the latest updates from Windows Update Get support For security related issues Get help about Security Center Change the way Security Center alerts me Security Center helps you manage your Windows security settings To help protect your computer make sure the three security essentials are marked ON IF the settings are not ON follow the recommendations To return to the Security Center later open Control Panel What s new in Windows to help protect my computer Firewall 2 Automatic Updates 7 Virus Protection Manage security settings for ty Automatic Updates Internet Options Windows Firewall t Microsoft we care about your privacy Please read our privac 3 Click Windows Firewall 4 Select the Exceotions t
6. The cards assigned to this user up to 16 cards The PIN code assigned to this user User properties General Codes Details Card Codes Card Type Facility Code Card Number Status Wiegand 26 bits v Active Add From MD O8 Add From List PIN Code Number of digits 4 to 8 Auto PIN a Duress PIN Code Auto PIN a g The Codes tab contains the following fields Table 16 Departments Users gt Department gt User Properties gt Codes Tab Field Description Card Type The card type used by the reader user Facility Code The site code assigned to this card Card Number The unique number of this card Status Select the status of the card Inactive cards cannot gain access to the facility Number of digits Select the length of the PIN for this user Add from MD D08 Click to read card details using MD D08 module Add from list Click to add a new card All cards within the user s specified facility code are listed Code The 4 to 8 digit PIN and or Duress PIN code Auto PIN Click to automatically generate a random PIN 74 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 5 13 2 3 Details Tab The Detai s tab contains detailed contact and identification details about the user User properties General Codes Detalls T elephone Home telephone Mobile _ Car registration Fag Title Employment date 121700 Address Notes The Detail
7. 3 On the toolbar click the icon The Manual Outout Operations window appears Manual Operations Output Options C Open momentarily closed by timer cos 3 min sec Open permanently closed by Close output and return to default mode Close output and return to default mode 1 Panel S Door Select All 14Panel 3 0utput 14 14Panel 3 Qutput 2 14Panel 3 Qutput 24 116 AxTraxNG Software Installation and User Manual Manual Operation SECURITY PRODUCTS 4 Select an option Open momentarily Opens all selected outputs for the time set in the timer box Open permanently Opens all selected outputs Close output and return to default mode Closes the selected outputs and returns control to default 5 Select the checkboxes of the outputs to which to apply the operation 6 Click OK 9 4 Manually Disarming Inputs The Manual Inout Operation window allows an operator to disarm a selected group of Inputs directly on a panel An armed input means the input is active a disarmed input is inactive and does not trigger any operation or alarms To manually disarm or rearm an input 1 In the Tree View expand the Networks element and expand a selected network 2 Select a panel 3 On the toolbar click the icon The Manual Input Operations window opens Manual Operations Input Options Input permanently disarmed Arm input and return to default mode 1 Panel
8. delete the panel by clearing the Enable panel checkbox in the panel screen Click OK 8 Select the Enable panel checkbox in the panel screen and click OK This action causes a full reset of the access control panel with the factory settings 9 Dial to the appropriate access control panel and click password in the modem status screen Use AxTraxNG as the current password and change the password to a new one AxTraxNG Software Installation and User Manual 139 Configuring User Counters E Configuring User Counters You can use the User Counter options to limit the number of entrances of a particular user This is done using the Counter option that appears on the User Properties window Figure 2 in Section 5 13 2 To contigure user counters 1 Go the Genera tab of the User Properties window either as part of the procedure of adding a new user as described in Section 5 13 2 or select an existing user in the Departments Users element 2 On the toolbar click the icon In the Counter section of the User Properties window select the Enable checkbox 4 Select the Set new counter checkbox and specify the number of allowed entrances for the user using the Counter value spin box Counter Enable Counter value Set new counter 100 gt 1 to 1000 5 Click OK Go the Genera tab of the Reader Properties Section 5 6 7 In the Details section select the Deduct User counter checkbox Deduct User counter 8 Cl
9. 29 4 1 Sarma UM SONI E eeii aiai aa adrad 29 4 2 AXiraxNG Main VV INOW sciatic dtisantnsenroemadedtooannatasonaiendanducemermndaiionsas 30 4 3 MONU BAT seyasi ieia amines eased EE E G a AG 31 4 3 1 EAR EE TEE EEE A ETETETT T 31 AxTraxNG Software Installation and User Manual iii Table of Contents 4 3 2 TOONS IVC UI cs oase tak wales A wae E oeseeeniceatiad 31 4 3 3 VION CU EEA E E E O EO OE EE tae EE EE mustered 32 4 3 4 Helo Mentinerea e a N 32 Ad TOODI nasie e E a S 33 4 4 1 Generallicon madita a a aA 33 4 4 2 General Network ICONS seaca ina aed Re 33 4 4 3 NEIWOLK ICONS a A a A A E ey een 33 4 4 4 Paner CON aree a E S T ptt aaa 34 4 4 5 C OSETIO S aia a S 34 4 4 6 REPDONSICON igrae E a N e tant aed alees 34 4 4 7 Events Toolbar ICONS sssr cae 35 4 5 TREO VIEW rts a A E EAE 36 4 5 1 AC NENO K S eana a a a ances 36 4 5 2 FHOMELOG era a ue GE AA E A OO i A A AA T 36 4 5 3 CAMES shrine paket eira a esaa e e E R 36 4 5 4 TAUNO ee E E EE E E E AE S 36 4 5 5 OUDE Na a E Ue Tere nn IR et Ree en een en Mena Te cen 37 4 5 6 Global AntipassDaTk 2 cess cuinnssatutindedieinabtrcntsnsedes inna sdendioandinlnpbsnenksosedusinpasaunt 37 4 5 7 Gar PARKING aana S 37 4 5 8 Se ean Renee nT eae E Regt eee ener REE ROE E eee ee ee eee me E ee 37 4 5 9 SEIS Ta access pce st Pact hat sli gas aes dak amo agua ee cena eae aah tani ees 38 4 5 10 REDOT tautsectactadencee sansa a a E R 38 5 Setting Up a SIt isisisi kapuni iaaa aa 39 oF Adding Ti
10. AxTraxNG Access Control Management Software Software Manual Version 22 x E AxTrax NG v 0 10 0 Le A Ele ook yew tiep AxTrax NG Table View x p rh Networks a E chy Network 2 cia Network 3 OS Prell E oors Readers Ingats t touts Urks amp Cameras Timing Tare Zone A Hobdeys 888 Groups hy Access Groups a 5 Access Output Groups 4 Fou Gops a Gobel artipassbads Users F Status Map 4 Reports M wrenediate 5 Archives avons Dh ee Everts x m ji e Event Communication restored Communication restored Communication restored No communication for over 3 mirits 7 Mobdays 8 Gos phy Access Groupe a D Access Areas 2 Opt Groups z Input Groups Iba rtpassdsds Users F Status Map D Reports Inmedate Arctives DHHS Everts m amp ji p Gi conected ME Download count 0 rROSSLNVT R SECURITY PRODUC TS Copyright 2013 by Rosslare All rights reserved This manual and the information contained herein are proprietary to REL RSP Inc and or their related companies and or subsidiaries hereafter ROSSLARE Only ROSSLARE and its customers have the right to use the information No part of this manual may be re produced or transmitted in any form or by any means electronic or mechanical for
11. Start DST date If Every year is not selected select the commence date for daylight saving time Month Week Day These fields are enabled when the Every year checkbox is of Week selected Select the month week within the month and day of the week when daylight saving time is to begin every year Stop DST date If Every year is not selected select the end date for daylight saving time Month Week Day These fields are enabled when the Every year checkbox is of Week selected Select the month week within the month and day of the week when daylight saving time is to end every year 11 Set the Daylight Saving Time definitions according to the field descriptions in the table 12 Click New from within Network tab to add a new network 13 Click OK to exit the Network s Time Zone setup window 5 4 Adding Access Control Panels Every network is a cluster of access control panels In its standard form each access control panel can be configured as either one or two readers per door Each of the AC 215 AC 225 and AC 525 panels have two readers and can be contigured as a one or two door panel Each AC 425 panel has four readers and can be configured as a two or four door panel When using an optional MD DO2 supported by AC 225 or AC 525 or MD D04 supported by the AC 425 reader expansion board each panel has four or eight readers and is configurable as such AxTraxNG Software Installation and User Manual A5 Setting Up a
12. The nput Properties window opens Location Description Type Activity start delay Input 1 1 Panel 2 Door 1 REX Normally Open v 00 00 Input 14 1 Panel 2 Door 1 Monitor Normally Close v 00 00 b Input 2 1 Panel 2 Door 2 REX Normally Open 00 00 Input 24 1 Panel 2 Door 2 Monitor Normally Close v 00 00 6 Select an input and configure it as required 5 8 Adding a Camera See Chapter 6 5 9 Adding Panel Links Panel links are rules defining how the system should behave when events occur in the access control panel The Link Properties window displays the following An event on a panel and the panel component to which the link response applies The required input or output response Any alarm message to display on the current AxTraxNG Client computer The Add Link window contains the following fields Table 13 AC Networks gt Network gt Panel gt Links gt Add Link Window Field Description Source Type Select the panel component type input output reader and so on which is the event source Source Select the specific panel component that raises the event based on the source type selected Up to 8 links can be created for each source type in the AC 225 AC 425 and AC 525 panels Up to 2 links can be created for each source type in an AC 215 panel Event Select the event type for the panel component Event Type the link or event description Description Enabled Select the checkbox to enable the link rule
13. e TCP IP e Modem 9600 19200 57600 and 115200 bps 14 AxTraxNG Software Installation and User Manual Specifications and Requirements SECURITY PRODUCTS 2 2 System Requirements 2 2 1 AxTraxNG Server and Client Requirements Operating System Windows XP SP2 Windows Server 2003 Windows Server 2008 32 64 bits Windows Vista or Windows 7 32 64 bits Processor Pentium 4 or better Memory 4 GB Network LAN card required for TCP IP networking Hard Disk Space 4 GB minimum 2 2 2 SQL Express Server Requirements SQL Server Express is not always required See Section 3 1 for further information Processor Pentium 4 or better Memory 2 GB Hard Disk Space 4 GB 2 2 3 HASP USB Key Requirements 1 64 Active Panels HASP key not required 65 256 Active Panels Level 1 HASP key required 257 512 Active Panels Level 2 HASP key required 513 1023 Active Panels Level 3 HASP key required AxTraxNG Software Installation and User Manual 15 Installation 3 Installation The AxTraxNG installation CD ROM includes all the setup files required to install the AxTraxNG Access Control software on the system s main computer The software system consists of the following four main components AxTraxNG Server Manages the database linked to the access control panels AxTraxNG Client Configures the system The AxTraxNG Client is only needed on the main computer however it can be installed on additional com
14. 9 100 0 Audio to Camera F Microphone Device Enabled Realtek HD Audio Input v Note On enabling Audio to Camera you must set Remote MIC IP address at Web browser of AC 525 92 AxTraxNG Software Installation and User Manual ViTrax Video Integration SECURITY PRODUCTS 5 Click OK p The ViTrax Server must be running to view recordings b Note For more information on camera properties see the W7rax Software Installation Manual To access Live Video 1 In the Events toolbar above the Event Log area click the icon A list of all available cameras appears itrax Cameras list Location IP Address Chanel ViTrax Server 1 Panel 1 4C 5254004 Camera 4C 525 A localhost 2 Double click the desired camera row The Live Video Streaming window opens a WW yw WWW AxTraxNG Software Installation and User Manual 93 ViTrax Video Integration The Live Video Streaming window includes the following buttons Table 20 Events Toolbar gt Cameras gt Live Video Streaming Window Icon Name Click icon to aj Recording Starts stops recordings that are saved as streams to the archive d Audio to Camera Use the PC microphone by utilizing the panel RAM mm Snapshot Save the current snapshot 3 Click OK to close 6 6 Automated ViTrax Camera Activation Options The following automated camera activation options are available in networks utilizing the ViTrax ca
15. 91 9975768824 sales in rosslaresecurity com ROSSLN SECURITY PRODUCTS www rosslaresecurity com ey TUVRheinland P A CERT 1S0 9001 ISO 14001 0706 0960417 01
16. Associate to the new user s created to an Access group Define the users right properties e Antipassback immunity Select the checkbox to override any antipassback restrictions e Extended door open time Select the checkbox to activate the extended door option defined for each door Select the checkbox to define automatic pin codes select between e Start from Sequential pin code starting from a predefined number based on a defined number of digits e Random Random pin codes where the only definition is the number of PIN code digits Define the access right validity e From Define the date and time to begin allowing access e Until Select the checkbox to define an end date for the access right validity then define the date and time Select the checkbox to define associated link commands e Access Granted command Activate a user defined set of inputs or outputs for access granted events e Access Denied command Activate a user defined set of inputs or outputs for access denied events e Handicapped checkbox Activate a dedicated output a short time after the door is unlocked The outputs are set in the Links window e User selected Output group Select an output group for this user The outputs are triggered every time the user accesses a door The operations inputs and outputs are defined in the Links window see Section 5 9 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS
17. Contact Closed Enabled Time Zone C Generate Alarm Always a Configure the link rule as required according to the field descriptions in the Table 13 Select the Generate Alarm checkbox to activate the Alarm Handler button Click Alarm Handler The Alarm Handler window opens Alarm handler PC SOFIA Message Popup Alarm Message C Popup Enabled Use highlight alarm event Fire Input Alarm Select Color C Open all Outputs of selected Output group Sound Select Wave Audio file Configure the alarm handler as required according to the field descriptions in the table above AxTraxNG Software Installation and User Manual 61 Setting Up a Site 9 Click OK to close the A arm handler window and return to the Link window 10 Click OK to close the Zink window and save the link rule configuration 5 9 1 Creating a Fire Alarm Input You can configure the panel properties to generate a fire alarm warning To create a fire alarm input 1 In the Tree View click AC Networks 2 Select a network and expand a panel in the Tree View 3 Select AC Links 4 On the toolbar click the P icon The Add Link window opens Source Type Destination Type v None Source Destination Input 1 1 Panel 2 Door 1 REX v None Event Operation Contact Closed v None Event Description Contact Closed Enabled Time Zone C Generate Alarm Always k 5 Con
18. Door Controller gt Panel Properties gt General Tab c eee 47 Hardware Test Screen ccccccccccccceccceeeeceeeeeeeeeeseeeeeeeeeeeeeseeeeeseeeeeaas 48 Network gt Panel Properties gt Antipassback Tab cece 50 Network gt Panel Properties gt Options Tab cccccccccceeeeeeeeeee anes 50 Network gt Panel gt Doors gt Door Properties ccccccceeeeeeceeeee eee es 53 Network gt Panel gt Readers gt Reader Properties gt General Tab 55 Network gt Panel gt Readers gt Reader Properties gt Options Tab 56 Network gt Panel gt Readers gt Reader Properties gt Access Event Tab57 Network gt Panel gt Inputs gt Input Properties ceeecceeee ees 58 AC Networks gt Network gt Panel gt Links gt Add Link Window 59 Cards gt Add Users and Cards WINdOW ccccccceseececceeseneeeeeeaes 68 Departments Users gt Department gt User Properties gt General Tab 72 Departments Users gt Department gt User Properties gt Codes Tab 74 Departments Users gt Department gt User Properties gt Details Tab 75 Departments Users gt Visitors gt Add User gt Visitor s Options Tab 76 Network gt Panel gt Cameras gt Camera Properties Window 91 Events Toolbar gt Cameras gt Live Video Streaming Window 94 HomeLogiX gt HLX Panel gt Links gt HLX LINKS ee eeeee eee 110 AC Networks
19. Enter readers to the defined Area To implement Antipassback on Exit readers as well you must define a new area with opposite reader directions Readers defined Enter in the first area need to be defined again in the new area as Exit readers and Exit readers in the first area should be defined as Enter readers in the second area 5 16 Car Parking The Car Parking management option allows you set up groups that have limited number of users who can access a particular area For example a parking lot that serves several companies and each company has a specified number of parking spots With this option we can set up each company s limit and when the limit is reached access is no longer granted This feature Is counter based that keeps track of the number of users in a specified area This feature is only available to Access Control panels AC 225 AC 425 and AC 525 Only one car park area can be added per panel AxTraxNG Software Installation and User Manual 79 Setting Up a Site To define a car parking area 1 Create an access area with Enter and Exit readers see Section 5 14 2 In the Tree View select Car Parking 3 On the toolbar click the SF icon The Car Parking window opens Car Parking Description Car Parking 1 Access Area car park Checked by Alea masimum counter Access Aea User Groups In Description enter a name of the car parking element 5 In Access Area select the re
20. For more information see W 7rax Software Installation Manual Be sure that the ViTrax Server is installed on a PC and you know that PC s IP address If not refer to the W7rax Software Installation Manual for installation instructions Perform the following steps to integrate the ViTrax server Step Action Section 1 Connect to ViTrax Server 6 1 2 Adda Camera to AC 525 Panel 6 2 3 Linking a Camera to AxTrax 6 3 4 Use Panel Links 5 9 and 6 4 5 View Recorded Events 6 5 6 Use Automated Activation Options 6 6 6 1 Connecting to ViTrax Server Define the ViTrax Server database with which the AxTraxNG Software communicates To connect to the ViTrax server 1 When the ViTrax Server is running click File gt ViTrax Server The W7rax Servers window opens ilTrax Servers IP Adress User Name Status 2 On the toolbar click the F icon The Add VWiTrax Server window opens 86 AxTraxNG Software Installation and User Manual ViTrax Video Integration SECURITY PRODUCTS Yilrax Server Yil ras IP Adress SOFIA Vilrax User Hame Po Yil ras Password 3 In WTrax IP Address enter either localhost or another IP address name In WiTrax User Name enter the username 5 In WTrax Password enter the password The entered password must resemble the non default password for the A server Note 6 Click Connect 7 Click OK When connected the Connected st
21. Generate Alarm Select the checkbox to generate an alarm event in addition to the link rule activity Destination Type Select the panel component type which is to be activated by the link rule trigger event Destination Select the specific panel component which is to be activated by the link rule trigger event AxTraxNG Software Installation and User Manual 59 Setting Up a Site Field Description Operation Select the operation performed by the destination panel component Time Define a duration timeframe for the operation This box is only available when a time bound operation is selected Time Zone Select the time zone for which the link rule applies PTZ Preset Set the default preset PTZ Pan Tilt Zoom camera position position Note To activate this feature you must set the preset to available with ViTrax AC 525 Alarm Handler Opens the Alarm Handler configuration window which contains the following fields e Alarm Message Type a personalized message to be displayed on the screen as an alarm message when the selected event occurs e Popup Enabled Select the checkbox to enable an alarm pop up message e Select Color button A color selection window opens allowing a color selection for the alarm message e Browse button Find and upload an audio wav file to be sounded when the selected event occurs e Sound Now button After uploading the audio file click to button to hear the audio file e Local Sound Enabled
22. I 1 BoE o EE E E E E A 150 2 Emor Log SendM aceiasi iiri on ies esaia 150 3 DE CONNEC IO esene i nii Ee A ii 152 4 BE essisrsrrsnosiernnniunnininnnin kanienn nenian kian EAEan aa 153 J Adding Custom Wiegand Formats ccscssesssseeeeneees 154 J 1 Representation ccccccccseeccceseecceueeceeseeeceeseeeeeeeeeeesseeeeeeseeseeseneeeees 154 J 2 Fe NSN E E E E A E E E ator E TT 155 L3 PANU Ga1 10 0 14 0 0 ee 155 JA Creating New Rules esses ssc acts ate nse ntentciaipennicinis np tartedctitacclopendingeaeontciode os 156 AxTraxNG Software Installation and User Manual Vil List of Figures List of Figures Figure 1 AxTraxNG Packages Selection Screen ccccccecccceeeseeeeceeeaeeeeees 17 Figure 2 User Properties gt General Tab 0 0 0 ccccccccccceessecceeceeeseeeeeeesaeeeeees 72 yili AxTraxNG Software Installation and User Manual List of Tables ee re Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 List of Tables AxTraxNG Client Main WINdOW cccccccccceeeeecceeeeeeceeeeeeeeeeeeeeaas 30 Add Network gt Options Tab cccccccccecccccceeeeceeeeesaeeeeseesaneeeeenaas 42 Add Network gt Options Tab cccccccceccccceeeeeeceeeeesseeeeeeesaeeeeeenaas 45
23. Panel network using 4xTrax Server time zone Panel network using different time zone Network s Time Zone Select Time Zone Windows Date and Time GMT 01 00 Amsterdam Berlin B em Rome Stockholm Vienna Custom Daylight saving Daylight saving date time Daylight Time 01 00 hh mm Every year Start DST time Stop DST time 02 00 hhmm 02 00 hhmm Start DST date Stop DST date Month Month April wj October Week Week Third First Day of week Day of week Sunday Sunday AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS The Network Time Zone area contains the following fields Table 3 Add Network gt Options Tab Field Description Select Time Zone From the dropdown list select the desired time zone Windows Date and Time Custom Daylight Select the checkbox to define custom settings saving Daylight Time Select the new hour at the time that daylight saving time begins Start DST time Select the hour that daylight saving time begins Stop DST time Select the hour that daylight saving time ends Every year Select the Every year checkbox to set a day in one of the weeks of a defined month to automatically begin and end daylight saving time every year Clear the Every year checkbox to set a date for one time setting of the beginning and end of daylight saving time In this case a new date must be set each year
24. Please note that the first character in the first row and the last character in the third row which represents the odd parity is a capital O and not a zero AxTraxNG Software Installation and User Manual 157 Adding Custom Wiegand Formats The new protocol now appears in the list of available protocols General Options Access event Details Description 1 Panel 1 Reader 1 In Out Open 14Panel 1 Door Direction Activation Type Reader type Operation mode Card Only Secured Card PIN time zone Never C Deduct User counter Keypad type Wiegand 26 bits Wiegand 37 Bits 10bit FC 16bit ID Clock and Data 6 digits Wiegand 37 Rosslare Wiegand 37 AwID Wiegand 29 for example y Inactive The representation of each existing protocol can be viewed To view the format of existing protocols 1 In the Tree View click AC Networks 2 Click Reader Type icon The Reader Tyoe window opens Reader Type Description Clock and Data Wiegand 35 Bits Wiegand 37 Bits Wiegand 32 Bits Wiegand 32 Bits Reversed Wiegand 34 Bits Wiegand 40 Bits Wiegand 40 PCSC Bits Wiegand 64 Bits Wiegand 37 Bits 10bit FC 16bit ID Clock and Data 6 digits Wiegand 37 long ID 16bit FC 1 Sbit ID Wiegand 37 Rosslare Wiegand 37 AWID 3 Double click protocol you wish you view in this case Wiegand 26 Bit Alternatively
25. 3 Door REX Select All 1 Panel 3 Door Monitor 1 Panel 34Spare Input 2 14Panel 3 Spare Input 24 4 Select an option Input permanently disarmed Deactivates all selected inputs Arm input and return to default mode Reactivates the selected inputs and returns control to default 5 Select the checkboxes of the inputs to which to apply the operation Click OK AxTraxNG Software Installation and User Manual 117 Manual Operation 9 5 Controlling Sirens Manually The Manual Siren Operation window allows an operator to test the siren for a selected panel To manually open or close a siren 1 In the Tree View expand the Networks element and expand a selected network 2 Select a panel 3 On the toolbar click the icon The Manual Siren Operations window opens Manual Operations Siren Options Open momentarily closed by timer min sec Close siren and return to default mode 4 Select an option Open momentarily Sounds the siren for the time set in the timer box Close siren and return to default mode Silences the siren and returns control to default 5 Click OK 9 6 Manually Update Firmware The Uodate Firmware window allows an operator to update the firmware version of the selected access control panel To perform a firmware update manually 1 In the Tree View expand the Networks element and expand a selected network 2 Select a panel 3 On the
26. A6 2C which is represented as 01001100 10010001 10100110 00101100 in binary All the bits in the protocol are represented with Z Card number is represented in the protocol as a BCD code each nibble represents one decimal character For example if the number decimal is 658723 then it is represented in binary as 01100101 10000111 00100011 All the bits in the protocol are represented with B J 2 Facility Code If supported in the card the software must know where It is placed inside the bit array and how many bits it takes Of the 5 representation options presented in J 1 only the data format can be used with the Facility code however all the bits in the protocol are represented with F to differentiate it trom regular data J 3 Authentication Usually the array of bits that represents the card number also contains an authentication mechanism that checks that the data was transferred correctly AxTraxNG supports several types of authentication mechanisms as follows Even Parity One bit provides authentication to either several bits proceeding or following it according to the defined protocol This bit makes the total number of related bits an even number The Even Parity bits in the protocol are represented with E and all the bits that they verity are represented with 1 Odd Parity One bit provides authentication to either several bits proceeding or following it according to the
27. Add First Name Middle Name Last Name User Number Department Access Group Car Parking Group Card Card Group Identification 72 Description Click to add a photo of the user or to remove an existing photo The selected photo aspect ratio should be 1 25 H x 1 00 L otherwise the photo may be distorted Type the user s first name Type the user s middle name Type the user s last name Type a unique user number to identify the user Select the user s associated department Select the user s access group Select to add a user to a defined Car Parking group Select to add a user to a defined Car Card group Add text that identifies the user AxTraxNG Software Installation and User Manual Setting Up a Site Field Color Location Valid date gt from Valid date gt until Counter gt Enable Counter gt Set new counter Counter gt Counter Value Rights gt Antipassback immunity Rights gt Extended door open time Rights gt HLX Am Links gt Access Granted command Links gt Access Denied command Links gt User selected Output group Links gt Handicapped check box AxTraxNG Software Installation and User Manual SSS U Sie em alealvleqrS Description Click to select which color to use to highlight this user when the user generates access events User highlighting must be activated in Tools gt Options gt General tab Click to display a log o
28. C Program Files Rosslare 4xTraxNG Server 5 Select the required installation location by clicking Browse or click Next to use the default destination The Database Server screen opens AxTraxNG Software Installation and User Manual 23 Installation ie AxTraxNG Server InstallShield Wizard Database Server Select database server and authentication method Select the database server to install to From the list below or click Browse to see a list of all database servers You can also specify the way to authenticate your login using your current In case of SqlExperss you need to add the instance name Veritrax to the computer name for example Computer 1 Yeritrax Database Server flocal Veritrax v Browse Connect using O Windows authentication credentials of current user Server authentication using the Login ID and password below Login ID sa Password rrTTitTititiiii 6 For the Database Server field do one of the following a Select the database server name from the dropdown list or use the default location oca Veritrax b Click Browse to choose the database server location i AxTraxNG Server InstallShield Wizard From the list of servers below select the database server you would like to target local VERITRAX ILANIT PC JERRY PC LENOVO E6762595 MIKAEL NATALIA PC AVISHAY RAMONPC ROSSLARE1 SRY RQLWERITRAX SARA NEWPC TAHLI PC
29. Cards element and select Card automation 2 On the toolbar click the F icon The Card automation window opens AxTraxNG Software Installation and User Manual 69 Setting Up a Site Card automation Automation Type Delete card automatically Automation description Delete card automatically Period m eles 3 From the Automation Type dropdown choose the action to be taken when a card has not been used in a certain period of time Delete card automatically Ask before card deletion Notify by email Report in System Event Log only 4 From the Period spin box choose the time period 5 Click OK 5 12 Card Design See Chapter 7 for how to create and print card templates 5 133 Adding Departments Users and Visitors Every user is associated with a department For each user AxTraxNG stores contact details associated card details and access rights 5 13 1 Adding Departments To add a department 1 In the Tree View select the Deoartments Users element 2 On the toolbar click the F icon The Add Department window appears Department Description Department 5 3 In the Description field enter a name for the department and click OK The window closes and a new department Is created 5 13 2 Adding Users Adding users to a department is done by using the Add User window 70 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS The Add User window contains
30. Ensure that the Design Mode checkbox is checked Select readers doors inputs outputs additional status maps cameras or panels and click the Add to Map icon from the toolbar menu The objects appear on the status map and can be dragged to their correct position 7 Right click a map object and select Show on Map from the shortcut menu The Show on Map window opens Show On Map 1 Panel 3 Door C Alarm Status By output O By Door Monitor 8 Select the Status checkbox to display the object s state on the status map 9 Foradoor s Show on Map properties select a By Door Monitor Shows the doors open status based on its physical position b By Output Shows the doors open status based on the status of its lock 10 Select the A arm checkbox to enable a visual alarm on the map for alarm events The alarm option is only available for panel elements where the alarm was already defined 11 Repeat Steps 6 to 10 until all objects are shown on the status map as required 12 Repeats Steps 1 to 10 to set up additional status maps Status map icons can also be added to other status maps indicating where the two map areas meet AxTraxNG Software Installation and User Manual 85 ViTrax Video Integration 6 Vilrax Video Integration ViTrax is a video management server client solution that supports AC 525 as well as a wide range of IP USB and open protocol cameras such as OnVif and PSIA
31. Fey AxTraxNG Server requires the following items to be installed on your computer Click Install to begin installing these requirements Status Requirement Pending Microsoft SQL Server 2005 Express P Install Cancel If you are upgrading the following screen opens AxTraxNG Server This setup will perform an upgrade of AxTraxNG Server Do you want to continue Welcome to the InstallShield Wizard for AxTraxNG Server The InstallShield R Wizard will install 4xTraxNG Server on your computer To continue click Next WARNING This program is protected by copyright law and international treaties 22 AxTraxNG Software Installation and User Manual l n sta ati O n SecURE eRODUCES To install the AxTraxNG Server 1 Click Yes and or Next to begin the AxTraxNG Server installation process If you are installing an upgrade skip to Step 10 Click Next The Setup Type screen opens i AxTraxNG Server InstallShield Wizard Setup Type Choose the setup type that best suits your needs Please check a setup type Server ve All program features will be installed Requires the most disk ott space 4 Select the Server option and then click Next The Destination Folder screen opens ie AxTraxNG Server InstallShield Wizard Destination Folder Click Next to install to this Folder or click Change to install to a different folder Ga Install 4xTraxNG Server to
32. Field Description Sequential Users Select the Enab e checkbox to use the counter option then Counter type or select the counter number to be used for the first user To add users and cards 1 In the Tree View expand the Users element and select Cards 2 On the toolbar click the icon The Add Users and Cards window opens Insert Users and Cards Sequential cards Selection type Reader type Add Users and Cards v Wiegand 26 Bits Quantity 1 Start from 1 To 65535 Facility code 0 To 255 lt 1 j 0 Sequential Users General C PIN Code Links Department C Access Granted command General C Access Denied command Access group C Handicapped Master f Valid date User selected Output group From None Rights 2975 11 x C Antipassback Immunity C Until Counter C Extended door open time 2s i CI Enable 1 to 1000 3 Configure the user and card properties as required according to the field descriptions in the table above 4 Click OK to close the window The process may take a few minutes after which a dialog reports that the operation has been completed 5 11 1 Setting Card Automation You can program the system to automatically keep track of any user card that has expired because of non use over specified period of time Once detected this card can either be deleted automatically or you can be notified of it To set card automation 1 In the Tree View expand the
33. M Address N Home telephone O Car registration P Title Q Notes R PIN Code Browse C S Card number C T Facility code 0 to 255 C U Identification Access Groups Import Access Groups Yes No User Number started from 1 Cancel The mportExport Data window contains the following fields Field Import Users Properties from external file into AxTraxNG Export Users Properties from AxTraxNG into external file Data Type Location Browse Excel File Columns Excel file Row User number started from Import Departments Tools gt Import Export Data Description Select this option to import user properties Select this option to export user properties Select the type of data file to import export Select the location of the file to import export Click to select the file to import export Select the checkboxes of the columns to be imported or exported Data in each column A T are imported or exported as listed Enter the first row of user data in the spreadsheet Enter the number from which to start assigning unique system user numbers Select Yes to import new departments into the AxTraxNG database Select No to import users without their departments AxTraxNG Software Installation and User Manual 127 Administrator Operations Field Description Department Select the department to assign to the imported users This box is
34. Set Time L Custom Date Time 4 Set the Date and Time as necessary 5 Click Apply 8 3 Updating Firmware After you have added the HLX panel to the system you should check that the firmware version is updated AxTraxNG currently supports firmware version is HLX40E_1_2 26 22 150812 Note To update a panel s firmware 1 In the Tree View expand the HomeLogiX element and select the HLX panel 2 On the toolbar click the icon The Update Firmware window opens 106 AxTraxNG Software Installation and User Manual Intrusion Integration SECURITY PRODUCTS Firmware update Are you sure you want to update firmware of HL panel HLX 1 bin file location C Program Files Rosslare AxTraxNG Client FirmwareSHLX40E_1_ 2 26 22 150812 bin Browse Data block length 240 4 v 3 Click Browse and select the HLX Tile relevant to the panel s hardware type 4 Click OK 8 4 Downloading from the HLX Panel Once an HLX panel is connected to the AxTraxNG software you can download various parameter groups from the HLX panel to the AxTraxNG GUI for easy editing To download parameters from the HLX panel 1 In the Tree View expand the HomeLogiX element and select the HLX panel 2 On the toolbar click the icon The Download to HLX7 window opens Download to HLX 1 C Al C Account Information L Zones L Enrollment Security L Communications C Automation C Messages Select the va
35. Software Installation and User Manual 123 Administrator Operations The following database operations are available Table 23 Tools gt Database gt Available Databases Operation Description Periodic Backup Run a scheduled backup every specified number of days at the specified time Backup now Run a one time backup immediately Export Configurations Copy the contents of the database to the selected folder and Events Import Replace the current configuration based on the imported file Configurations Import Configurations Replace the current configuration and events based on the and Events imported file Erase Configuration Erase the current database configuration and all events and Events Limit Panel Events Automatically erase events when they are older than a Period specified number of days Before using this option Rosslare recommends that you set a periodic backup Note It is recommended to set the value to no more than 91 days Erase Panel Events Erase all events that are older than a specified number of days Import database Replace the current database with VeriTrax AS 225 or AxTrax versions earlier than databases AS 225 VeriTrax or AS 525 AxTrax Import database Replace the current database versions earlier than Note This option does not allow importing a AxTraxNG database from a current AxTraxNG version This option is only available in the AxTraxNG Server PC The Backup and Export funct
36. Tab The Genera tab in the Reader window displays The settings for how the reader operates The type of reader being used General Options Access event Details Description Operation mode 1 Panel 1 Reader 1 Card Only Direction In Secured Card PIN time zone Out Never Activation Open 1 Panel 1 Door 1 C Deduct User counter Type Primary Reader type Keypad type Wiegand 26 bits Inactive Secondary Reader type None C Check facility code only AYCW6500 Biometric Reader 54 AxTraxNG Software Installation and User Manual Setting Up a Site The Genera tab in the Reader window contains the following Table 9 Network gt Panel gt Readers gt Reader Properties gt General Tab Field Description Description Type the name of the reader Operation Mode Select how the reader operates Direction Secured Card PIN time zone Open Door Deduct User Counter Primary Reader type Secondary Reader type Keypad type Check facility code only AYCW6500 Inactive The reader is not in use Card Only The reader uses RFID cards only PIN Only The reader uses PIN inputs only Card or PIN The reader uses both cards and PIN codes Desktop The reader is inactive but is being used to record new cards on the computer e No Access Mode The reader does not grant access to any users Select whether the reader is allowing entry into the area or exit out of
37. a A AN 109 So Adang sa TAL LINK eiie an cel egart 110 8 9 Linking an AC Panel to an HLX Panel cceccccceeeeeeeeceeeeeeeeeeeaees 112 tO ATNI PA Aictattst a 8 cu eetteatt oie wenn eat 112 9 Manual Operation c1ccccsesessesesensseenseeenseeenseseneeeeeenes 114 9 1 Controlling the Door WIGAN a ss s5eatscntieescdvemersteeaioucicmtecaunawdon 114 9 2 Changing the Reader MOG Gai sec oc dsecahheiasd eds cian eta adenine eee 115 9 3 Controlling Outputs Manually essas aan ace alauets 116 9 4 Manually Disarming INPUTS cessen 117 9 5 Controlling Sirens Manually ssssnnnsssnnnnsssninussnrnnussrrrireesrrrreserrrrens 118 9 6 Manually Update Firmware cccccccccecccceeeeeeeeceesseeeeeceeeaeeeeeeeaaes 118 10 AxTraxNG Reports ccscscscsseseeseeeeneneeeeeeeeeeeeneneneneeses 119 101 mediate Repor Sisena a a a ttratac dds 119 10 2 Archive Reports eoosnnesennnueserinesesrrrrssrrrrsrrrrrssrrrresrrrrressrrrirresren 120 10 2 1 Panels EVENS REDOT S ansaan a E 120 10 2 2 System AxTraxNG Events Report eansennsisseinsnnerrrsrrerrrsrersrrsrrrrrrsrrnns 120 10 2 3 Interactive Report e ode ciceics th mesos cattrasion ed Ai tan va bishealeg Os ebb cat aaieied Uateoaeatestasioaieg Ab eee vant 120 yi AxTraxNG Software Installation and User Manual Table of Contents ees 11 Administrator Operations cccsscesssesseeeeseseeenseeenseeees 122 11 1 Setting the Time and Date encimiscsstsncacorusautacede
38. a selected time zone The 7ime Zone Properties window displays the selected periods for each day of the week It is possible to set a maximum of eight different time zone periods AxTraxNG Software Installation and User Manual 39 Setting Up a Site To add a new time zone 1 In the Tree View select Timing gt Time Zone 2 On the toolbar click the FF icon Wednesday Thursday Holiday amp v Friday Saturday New OK J Cancel Enter a name for the time zone Click and drag the mouse down a day column to select a time interval Right click the selected area and select Create ay gy Right click the selected area and select Properties to fine tune the time frame and then click OK 7 Repeat Steps 4 to 6 for each day You can move a defined time zone to a different day and time using drag and drop 8 Click OK when all of the time zones are defined You can create up to 8 time intervals for each day Note 5 2 Adding Holidays You can add and define annual holiday dates on which it is then possible to set special access behaviors There are two ways to add holidays Add a known national holiday s Add a new holiday To add a national holiday 1 In the Tree View select the Holidays element 2 On the toolbar click the a icon The Outlook Holidays window opens 40 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Outlook Holidays Select holidays
39. digital cameras for image capture This chapter instructs installers and users how to use the Card Design element 7 1 Creating a Card Template To create a card template 1 In the Tree View expand the Users 2 Expand the Cards element and select Card Design 3 On the toolbar click the F icon The Card Design Template screen opens Card Design Template Description Card Design 1 Scale Orientation Inches Landscape Centimeters Portrait Size ID Card 3 370 2 125 O 180 Card 3 375 2 175 Customized size set by user Width Height 4000 Inches Max 4 00 3 000 Inches Max 3 00 4 Enter a description for the template and define the scale orientation and size 5 Click Next The Card Design Fields screen opens AxTraxNG Software Installation and User Manual 97 Card Design Photo ID Card Design Fields Card Number User Number Last Name First Name Department Title Barcode in the card area Press Ctrl key and click to sign many Components Use right click to change the properties 2 Click and Drag the components from left and place them Static field 1 6 Right click the card area background to set the background color or to choose a file to use as the background Background Transparent Edit 7 As desired drag the fields on the left into the card area to create the layout
40. enables the Time Lapse option in ViTrax when setting recording by AxTraxNG Select the Time Lapse period By default the Time Lapse period is 0 005 frames per second 1 frame every 200 seconds Select the live audio volume Select the checkbox to indicate when a microphone is connected to the camera Enabled when the Audio to Camera checkbox Is selected From the dropdown list select a microphone Camera properties Video pop up window and snapshot options Streams saved in the PC Streams saved in the USB key Opens the images list stored on the PC Start Stop Recording initiate Audio to camera and Save current snapshot To access camera properties 1 In the Tree View click AC Networks The available networks are listed in the display area 2 Select a network and expand a panel in the Tree View 3 On the toolbar click the Fs icon The list of available camera appears in the display area 4 Double click the desired camera row within the camera list The Camera Properties window opens Camera Properties AC 525 003 E Motion Detection C Enable Vitrax Motion Detector min sec Note On enabling ViTrax Motion Detector you must set Motion Detector properties in ViTrax Camera Setup Wizard at Motion Analysis screen Time lapse Frame rate Enabled 0 005 fps Note Time lapse is automatically enabled due to camera recording settings Do not isable Live audio
41. rights The Visitor s options tab contains the following fields Table 18 Departments Users gt Visitors gt Add User gt Visitor s Options Tab Field Description Visitor Identification Type a unique visitor identification Visit Date Time Select the checkbox and specify the date and time for the visit Automatic disable Define automatic disable access right options on exit e Access Area Select the Access Area to disable access to e Inactive card The designated card automatically becomes inactive upon exit e Unauthorized user the designated access group changes to Unauthorized upon exit Hosted Define the details for the hosting party e Department Select the Department e User Select the hosting User e Comment Type any additional information 76 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS To create visitors 1 In the Tree View expand the Users element and select Visitors 2 On the toolbar click the FF icon The same Add User window as before opens however now the Visitor s Options tab is available User properties General Codes Details Visitor s options edi a Automatic disable on exit Visitor identification Access Area Global Visit Date Time Options Inactive card Unauthorized user Department User v General v Comment 3 Enter the visitor specific options as needed Enter the visitor s details in the v
42. section outlines a recommended step by step process for configuring AxTraxNG for a site Step Action Section 1 Add Time Zones and Holidays 5 1 and 5 2 2 Add a Network 5 3 3 Add and Configure an Access Control Panel 5 4 4 Configure the Doors 3 0 5 Configure the Readers 5 6 6 Configure the Inputs O 7 Add a Camera 5 8 8 Add Panel Links 5 9 9 Create Groups Access Groups Input Groups 5 10 1 5 10 2 and and Output Groups 5 10 3 10 Add New Users and Cards 5 11 11 Add Departments Users and Visitors 3 12 Add Access Areas and Add Global 5 14 and 5 15 Antipassback Rules 13 Add Car Parking 5 16 14 Add Operator IV 15 Add a Status Map 5 19 The AxTraxNG system performs an automatic data download for any parameter related to the hardware If panels are connected and active a download count appears on the status bar after any downloaded parameter change The counter shows 0 when a download is complete however it may also appear after a failed download It is the operator s responsibility to verify that the download operation succeeded or failed This can be verified in the system event list or by checking the failed download data manually see Section 11 2 5 1 Adding Time Zones A time zone is a group of periods within a week Door access rights as well as alarms and input and output behavior can all be set to behave differently for each time zone Many operations can be automatically enabled or disabled within
43. the Tree View expand the Reports element and select Immediate 2 On the toolbar click the F icon The Report Wizard opens Report Wizard This report wizard will help you create a new report You can press back at any time of to change your selections Roll Call Readers e 73 Roll Call Readers j Roll Call Areas NO ee I 3 From the dropdown list select a report type 4 Click Next Follow the on screen wizard instructions until the wizard has completed The display area lists the new report AxTraxNG Software Installation and User Manual 119 AxTraxNG Reports 10 2 Archive Reports You can produce three types of reports Panels Event Reports System AxTraxNG Events Reports Interactive Reports 10 2 1 Panels Events Reports Panel event reports display details of all recorded panel events There are six available panel event reports Attendance Report Lists the attendance hours for selected users sorted by date Results include hours present time in and time out Panels Report Lists all the events recorded by the selected panels sorted by date Access Report Lists all access events recorded by the selected readers sorted by reader and date Readers Report Lists all users who have accessed the selected readers sorted by department and date Fingerprint Report Lists specific fingerprints readers events sorted by reader and date Visitors Report
44. the panels in a network or on all the panels in the entire system 122 AxTraxNG Software Installation and User Manual Administrator Operations SECURITY PRODUCTS To download failed data 1 Inthe Tree View select a specific panel a specific network or all the networks 2 On the toolbar click the icon The download data process begins 11 3 Testing User Counters When using User Counters it is possible to view the current User count value in each panel that has a Reader designated with the Deduct User option To view User Counters 1 In the Tree View select Users gt Department Users or Users or Visitors 2 Select one user or visitor in the display area 3 On the toolbar click the icon The Request User Count window opens Request user start Panel Panel Status Counter status Counter value Select All 14Panel 2 Connected Enable 1 15Panel3 Connected Enable a4 E _ SelectNone _ lone 2 Panel 2 Connected Enable 4 Click Test 11 4 Maintaining the Database Use the Database window to maintain the system database To open the Database window 1 From the menu bar select Tools gt Database The Database window opens Backup now Backup folder PC sofia C Documents and Settings 4ll Users Application Data Rosslare Enterprises Ltd AxTraxNG Server 0 10 0 0 Backup Note The Data base file name will be appended with _AxTrax1_v5 AxTraxNG
45. three main tabs Figure 2 Genera tab Displays identification and control information Codes tab Displays card information associated with the user Details tab Records user contact details In addition there are two content oriented windows User Fre ds Stores user defined data Visitor Tab Appears when the user is defined as a visitor Section 5 13 3 5 13 2 1 General Tab The General tab displays User identification information User validity settings a Access rights for the user AxTraxNG Software Installation and User Manual 71 Setting Up a Site User properties General Codes Details a Rights Antipassback Immunity Figure 2 Never C Extended door open time C HLS Arm The General tab contains the following fields First Name 11 Last Name User Properties gt General Tab Middle name User Number 1 to 2000000000 1 Department Access group General Master Car Parking Group None Identification Card Card Group None Valid date From 10 29 2012 00 00 4 Counter Enable C Set new counter Links C Access Granted command C Access Denied command C Until Counter value 1 to 1000 User selected Output group None v C Handicapped Table 15 Departments Users gt Department gt User Properties gt General Tab Field Photo gt
46. to import OS C Andorra C Argentina C Australia l C Austria C Bahrain E Ce Ee C Belgium C Bolivia C Brazil C Bulgaria C Canada a C Chile w _ Christian Religious Holidays C Colombia C Costa Rica 4 _ Croatia C Czech Republic C Denmark C Ecuador E C Egypt H H 3 From the list find the relevant country and either a Select the main checkbox to select all holidays for that country b Expand the checkbox and choose which holidays to add 4 Click Import 5 Click OK to confirm 6 Click OK to close the Options window To add a new holiday 1 In the Tree View select Timing gt Holiday 2 On the toolbar click the F icon The Add Holiday window opens Description Enabled Date 30 May 2011 C Every Year New 3 In Description enter a name for the holiday 4 Select the Enabled checkbox to enable the holiday 5 Use the Date dropdown to select the holiday s date 6 Select the Every Year checkbox to repeat the date yearly 7 Click OK AxTraxNG Software Installation and User Manual 41 Setting Up a Site 5 3 Adding a Network A network is a group of up to 32 access control panels AxTraxNG communicates with each access control panel that is part of the network The Network window includes the following information The network s name address and activation status The DIP switch settings for the communicatio
47. toolbar click the icon The Update Firmware window opens Firmware update Are you sure you want to update firmware of panel 2 Panel 2 ahes file location E Applic AxT raxNet Client Veritrax Client bin Firmware ac21 5v04_02_00 hex Browse 4 Click Browse and select the HEX file relevant to the panel s hardware type 5 Click OK 118 AxTraxNG Software Installation and User Manual AxTraxNG Reports SECURITY PRODUCTS 10 AxTraxNG Reports AxTraxNG supports two types of reports Immediate Reports List details of recent movements within the last few hours They are shown in the display area and can be exported Archive Reports List all events in the database 10 1 Immediate Reports There are four types of immediate reports Who s been in today Lists where and at what time each user was granted access for the first time today Last known Position Lists where and at what time today each user was most recently granted access Roll Call Readers Lists the last time each reader was given access and by whom within the last 1 99 hours Roll Call Areas Lists all users currently within the selected area sorted by department and entry time The report lists all personnel who entered the facility within the last 1 99 hours To show an immediate report select it from the Reports element of the tree view under Immediate To create a new immediate report 1 In
48. 130 AxTraxNG Software Installation and User Manual Firewall Configuration SECURITY PRODUCTS 8 Click OK The SQL Server program appears in the Add a Program dialog 9 Repeat Steps 6 and 7 10 In the File Name box type C Program Files Microsoft SQL Server 90 Shared sqlbrowser exe and click Open 11 Click OK The SQL Browser program appears in the Add a Program dialog 12 In the Control Panel click the Performance and Maintenance category When in Classic View click Switch to Category View in the top left Control Panel preferences pane and then click the Performance and Maintenance category The Performance and Maintenance window opens Fie Edt wiew Favorites Tools Help Osx gt QO PP Psearch rodes M Address e Performance and Maintenance Performance and Maintenance Pick a task 3 See basic information about your computer gt Adjust visual effects gt free up space on your hard disk gt Rearrange items on your hard disk to make programs run faster or pick a Control Panel icon ess Administrative Tools ba Power Options iW ig sy Scheduled Tasks SA system 13 Click Administrative Tools The Administrative Tools window opens t Administrative Tools DER File Edit View Favorites Tools Help ay Q pak B LPSearch Fy Folders E Address 4 Administrative Tools i Go File and Folder Tasks ey I ey e 5 Component Computer Data Sources Event Viewer Perfor
49. 5 14 4 5 6 Global Antipassback Antipassback rules can be applied to each access area to prevent one user s card or entry code trom being used for two subsequent entries and to prevent a second entry without a previous exit For more information see Section 5 15 4 5 7 Car Parking The Car Parking management option allows you set up groups that have limited number of users who can access a particular area This feature is counter based that keeps track of the number of users in a specified area For more information see Section 5 16 4 5 8 Users The Users tree branch consists of five elements Departments Users Visitors User Filter Cards and Operators 4 5 8 1 Departments Users This element shows a list of all departments and users as well as any visitors registered in the system Each user is a member of a department For each user it is possible to assign cards and or a PIN code set access rights personal details and include an identification photograph For more information see Section 5 11 AxTraxNG Software Installation and User Manual 37 System Overview 4 5 8 2 Visitors This element shows a list of all visitors registered in the system Visitor type users can also be created with specific access rights For more information see Section 5 13 3 4 5 8 3 User Filter This element allows you to find users in the database based on various search parameters such as name user number and access group The fil
50. A arm handler window see Section 5 9 Alarm handler PC SOFIA Message Popup Cameras options Alarm Message Camera Camera Options Pop up Live video window Close window options By timer 0 04 min sec O Manually Select Color Popup Enabled C Popup Enabled Use highlight alarm event Sound Select Wave Audio file Select a camera from the Camera dropdown Select a video option from the Options dropdown Select the Popup Enabled checkbox to enable local pop up messages oe es Under C ose window options select either Manually or By timer 6 Click OK 6 6 3 Camera Event Create camera event based automatic camera activation To create camera event based camera activation 1 Open the Camera Properties window see Section 6 5 2 Click Options The Video Popup and Snapshot window opens ideo Popup and Snapshot C Popup Camera Window on Vitras recording Window opens for recording duration Motion detected Popup Window on Motion detected start Pop up Window type Live video Snapshot AxTraxNG Software Installation and User Manual 95 ViTrax Video Integration 3 Select the Popup Camera Window on ViTrax recording checkbox to enable window pop up on the PC during camera s ViTrax recording 4 Select the Popup Window on Motion detected start checkbox to enable window pop up on the PC following an activation of the ViTrax Motion detection 5 Under Close win
51. Active Dire If the setting is set on a domain controller you may need to run GPU date to force the changes to propagate Note 146 AxTraxNG Software Installation and User Manual SQL Server Installation Troubleshoot If the server is not part of a domain check the local security policy 1 Open the MMC console Start gt Run gt mmc exe 2 Click File gt gt Add Remove Snap in 3 AxTraxNG Software Installation and User Manual 147 SQL Server Installation Troubleshoot 4 148 Disable temporarily the security policy Console 1 Con mo sole Root Local Computer Policy Computer Configuration Windows Settings Security Settings Account Policies Password Policy i File Acton View Favorites Window Help 9 2 0 gt HT Console Root Poy o flet E Computer Management Loc L Enforce password history 0 passwords Wea oe ay E jf Local Computer Policy Si Maximum password age E A Computer Configuration lt q Minimum password age E Software Settings 2 Minimum password length 0 characters za Store passwords using reversible encryption sabled C Software Restriction Polite 5 Application Control Policies a IP Security Policies on Local Cmput D Advanced Audit Policy Config ghy Policy based Qos Administrative Templates f E gi User Configuration m O Software Settings Windows Settings D Administrative Templates AxTraxNG Soft
52. Audio file 11 From the Camera dropdown choose the camera you wish to link 12 From the Options dropdown choose how the alarm is generated Alarm handler PC RQ1 Message Popup Cameras options Alarm Message Camera USB Video Device Options Pop up Live video window Pop up Live video window X Show Snapshot and save to archive Recording C Popup Enabled Use highlight alarm event Input 1 Select Color Sound Select Wave Audio file Browse 13 Click OK to close the A arm handler window and return to the Link window 14 Click OK to close the Zink window and save the link rule configuration 90 AxTraxNG Software Installation and User Manual ViTrax Video Integration SECURITY PRODUCTS 6 4 Conditioned Recording via Panel Links You can select the source destination and period of recordings using Conditioned Recording sequences programmed via the Pane Links screen To create a panel link 1 In the Tree View click AC Networks The available networks are listed in the display area 2 Select a network and expand a panel in the Tree View Select AC Links 4 On the toolbar click the FF icon The Add Links window opens Source Type Destination Type Reader Local recording v Source Destination Reader 1 3 Panel 15Reader 1 Camera momentary recording v Event Operation Access Granted any user Timer Event Description l Time m
53. Door Properties Field Description Auto Relock REX enabled First person delay on automatic unlock Door output polarity is Normal Closed Manual Door Open Enabled Door open time Extended door open time Door held open Door forced open Description Type a name for the door Select the event that causes the door to relock automatically A Request to Exit unlocks the door for a user defined duration Select the checkbox to allow Requests to Exit for this door The location of the door REX input depends on panel configurations it can be seen in the Panel properties window Sets the door s behavior during an automatic unlock time zone Select the checkbox to require that during the selected Time Zone the door remains locked until the first user opens it The automatic unlock time zone is selected in Panel Links by selecting the output corresponding to that door see Section 5 9 Select this checkbox to ensure Fail Safe door opening if the Fail Safe door Lock Device power fails Once enabled the door output relay is activated when the door is closed and is deactivated when the door is open In this configuration the Fail Sate lock device should be wired to the door relay N O Normal Open and COM Common terminals Select this checkbox to allow operators to adjust the door manually see Section 5 9 Set the duration for which the door stays unlocked Set the duration for which the door stays unlocked for users
54. Install AxTraxNG Client to C Program Files Rosslare AxTraxNG Clienti InstallShield j Cancel AxTraxNG Software Installation and User Manual 19 Installation 3 Select the required installation location by clicking Change or click Next to use the default destination The Ready to Install the Program screen opens fe AxTraxNG Client InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard 4 Click Install The nstalling AxTraxNG Clrent screen opens When the installation is complete the nsta Shield Wizard Completed screen opens 5 Click Finish to complete installing the AxTraxNG Client software 3 4 HASP Device Driver Following the AxTraxNG Client software installations the wizard for the HASP device driver installation appears ca HASP Device Drivers Installation E Welcome This program will install the HASP device drivers for Windows 95 98 ME Windows NT 2000 4P 2003 Vista x86 64 HASP HL is also supported by these drivers HASP Device Driver version 5 22 In order to update the device drivers all open processes accessing the driver have to be closed If you have any running applications please close them now otherwise the installation program tries to terminate the processes by
55. Install to begin the installation TF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard 4 Click Install The installation process begins When the installation is complete the nstal Shield Wizard Completed screen opens 5 Click Finish to complete the AxTraxNG Watchdog software installation A window opens telling you to restart the computer You must restart the comptuer to complete the installation After Windows restarts please wait two minutes for the 4xTraxNG server to start before using the 4xTraxNG Client 6 Click OK 7 Return to the AxTraxNG Elements Selection Screen Figure 1 8 Click Close and then restart the computer The AxTraxNG server is now Tully installed on your computer Once the computer restarts you must wait until you see a message in the Windows system tray that the server is connected 43 Server connected Rise GF OX 11 59 4m 3 7 Video Enhancement for AC 525 Setup AxTraxNG can connect with single or multiple ViTrax servers installed in a LAN or WAN configuration AxTraxNG Software Installation and User Manual 27 Installation Make sure to check AxTraxNG and ViTrax version compatibility To install ViTrax Server and Client applications refer to the W7rax Software Installation Manual When installing AxTraxNG on a different PC make sure that the ViTrax Server has already been i
56. Lists visitors who have made a visit to a certain user or department or lists all related visitors 10 2 2 System AxTraxNG Events Report System AxTraxNG events reports list details of system and operator activity There are three available system event reports System Report Lists all operations performed by the AxTraxNG server sorted by date Operators Report Lists all the operations performed by registered system operators sorted by operation event type and date Alarm and Antipassback Handler Report Lists all raised system alarms sorted by operator and date 10 2 3 Interactive Report Interactive reports list details of users and their access activity There are two available interactive reports User Access Rights Report Lists site access details for selected users with full details of readers accessed and in which time zones Not Responding Users Report Lists users for whom there have been no access events for a selected period of time To create a new archive report 1 Inthe Tree View expand the Reports element and select Archives 120 AxTraxNG Software Installation and User Manual AxTraxNG Reports SECURITY PROGUCTS 2 On the toolbar click the SF icon The Report Wizard opens Report Wizard This report wizard will help you create a new report You can press back at any time to change your selections Which type of report do you want to produce Panels events re
57. None Operators None Visitors None Reports None Nes 3 In the Description field enter the Operator s name Select the Localize guard checkbox to define the operator with limited rights 5 Click Networks and Status maps to define the associated operator s local rights 6 Set the operators global permission rights for each of the screens in the Location list 7 Click Password to open the Password dialog Operator Password Change password Current password New password Confirm password Note password will be sawed together with other properties of operator 82 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 8 Enter the operators password in the Password tield and re enter the password in the Confirm Password field On first time use leave the password field empty and enter and confirm your new password 9 Click OK to save your settings The dialog closes and the operator is shown in the display area 5 18 Creating Elevator Control Normally a reader is associated with a door For elevator control a selected reader should be associated with outputs groups with each output group representing a floor To create elevator control 1 Select a reader see Section 5 6 in the display area 2 On the toolbar click the F icon 3 In the Reader Properties window clear the Activation checkbox Activation C Open 14Panel 14Door 2 Cl
58. Properties window see Section 5 13 2 1 select the Card Card group from the Card Card Group dropdown 5 Click OK Repeat this process for each user you wish to add to a particular Card Card group 5 11 Adding Users and Cards The AxTraxNG database maintains a list of every user card or PIN that has ever been assigned The Add Users and Cards window is used to define The type of reader needed to read the card The number of cards to create Whether or not a user should be created for each new card AxTraxNG Software Installation and User Manual 67 Setting Up a Site The Add Users and Cards window contains the following fields Table 14 Cards gt Add Users and Cards Window Field Selection Type Quantity Sequential cards Sequential Users General Sequential Users Rights Sequential Users Pin Code Sequential Users Valid date Sequential Users Links 68 Description Select what will be added Users and cards Users only or Cards only Type or select the number of cards users to add Define the card properties e Reader Type Select the type of reader appropriate for the new cards being added e Start from Type the number of the first card in the set e Facility code Type the site code for these cards This field is not available for all reader types Define the users general properties e Department Associate to the new user s created to a department e Access Group
59. ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document This manual describes the maximum configuration of the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in the manual are for the purpose of illustration and reference only In no event shall manufacturer be liable for any special direct indirect incidental consequential exemplary or punitive damages including without limitation any and all damages from business interruption loss of profits or revenue cost of capital or loss of use of any property or capital or injury All graphics in this manual are for reference only some deviation between the image s and the actual product may occur All wiring diagrams are intended for reference only the photograph or graphic of the PCB s are intended for clearer illustration and understanding of the product and may differ from the actual PCB s AxTraxNG Software Installation and User Manual Introduction ees 1 Introduction
60. Select the checkbox to enable sound for the alarm e Fire Input Alarm Select this checkbox to open all outputs usually relevant for fire alarms The Alarm Handler function is only enabled when the Generate Alarm checkbox is selected In addition when a camera is linked to a panel the following fields appear in the window e Camera List of available cameras e Options How the alarm is displayed e Popup Enabled Activates a popup to appear on the user s screen when alarm is triggered e Close window options Can choose By timer and specify the time or Manually Numerous events and links can be defined in Panel Links It is the operators responsibility to avoid conflicting or non logical definitions Not all events sources that appear in the Links window are enabled in the panel this too is the operator s responsibility to verify Link condition operations should be checked after making any changes in the links definitions 60 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS To create a panel link 1 Zz 3 4 8 In the Tree View click AC Networks Select a network and expand a panel in the Tree View Select AC Links On the toolbar click the SF icon The Add Link window opens Source Type Destination Type v Nore Destination Source Input 1 1 Panel 2 Door 1 REX None Event Operation Contact Closed None Event Description
61. Site Use two readers per door when one door acts as both the entrance and exit to an area of the site When only an entry reader is required use one reader per door For example Use configuration with two readers per door set to IN and OUT to produce attendance reports Use one reader per door configuration to control two doors with an IN reader only premises will be exited using a REX switch or a mechanical door handle only When there is communication with the panel the Tx and Rx LEDs flash 5 4 1 General Panel Settings The Genera tab of the Door Controller Panel Properties window displays the following The panel s address and status The DIP switch settings for the panel If panel expansion boards are installed the tab also displays The input and output connections for the panel The panel s hardware version Refer to AC 525 Hardware manual for further details 5 4 2 Adding a Panel You can add an individual panel using the Tree View Alternatively it is possible to search for panels over the access control network using the Find Panels option This is particularly useful during installations AxTraxNG finds all connected panels in the network and checks them Panels can then be quickly activated and updated To add an individual panel 1 In the Tree View click AC Networks 2 Select an available network 3 On the toolbar click the 3F icon The Add Pane window opens 46 AxTraxNG So
62. The AxTraxNG Access Control System is a complete Server Client software management system for use with the AC 215 AC 225 AC 425 and AC 525 Access control panels The AxTraxNG Access Control System is user friendly intuitive and rich in functionality Using AxTraxNG you can configure door functionalities based on areas and time frame for different types of personnel and for varying alarm situations The AxTraxNG Access Control System can integrate with ViTrax Video Surveillance software application The main purpose of the integration is to enable video recording based on access control events and convenient playback This manual is compatible with AxTraxNG software Version 00 12 00 and above 1 1 System Features AxTraxNG makes It possible to control and monitor every aspect of access control on a site The system includes a built in software security system that controls access to the system database and logs all performed operations In addition the system boasts the following Professional Grade features A free basic Level O server software license for up to 64 panels Three incremental license levels can be activated by buying a Rosslare HASP key the CD ROM is provided with the package User friendly PC software with intuitive layout reduces the complexity of access control Manages user data photo and information fields access rights alarms strike time and door mode all from one central locat
63. The Menu bar controls the software s general operation and setup For more information see Section 4 3 2 Toolbar The main Toolbar consists of icons for the key tasks required in managing access control across a facility The available icons change according to the view selected For more information see Section 4 4 3 Tree View The Tree View allows users to configure monitor and control every aspect of access control For more information see Section 4 5 30 AxTraxNG Software Installation and User Manual Syste m Ove rvi ew SECURITY PRODUCTS Section Description 4 Event Log The Event Log displays a detailed log of every time access was granted or denied for every door on the site as well as when inputs and output are opened or closed The event log toolbar consists of icons allowing the user to monitor potential door tamper or forced entry attempts These warnings are logged and displayed as internal system warnings including video stream archives that are saved to the ViTrax database 5 Display Area The Display area displays all items within the selected Tree View element It also provides options to add edit or delete items manually without opening the detailed element windows In addition the display area provides various system updates 6 Status Bar The Status Bar displays server connection status Downloads Counter and the Firmware programming progress bar 4 3 Menu Bar The menu bar controls the general op
64. TraxNG recognizes them as a Facility code only This means that if a card has both a Site code and a Facility code AxTraxNG recognizes the first Facility code and the second Facility code Is ignored The authentication mechanism and its type inside the bit stream In most protocols there is a certain type of authentication of the data transferred from the reader to the controller Once the user knows the format of the card meaning how many bits there are per card the user can use the other two factors to create new rules which can then be enrolled into the software to teach the controller to understand the new format J 1 Representation The following options are available when discussing the number representation Card number is represented in a binary or hexadecimal code All the bits in the protocol are represented with D which stands for data Card number is represented in the protocol as a reverse bytes For example if the number hexadecimal is 34 65 89 32 then it is represented as 32 89 65 34 All the bits in the protocol are represented with R Card number is represented in the protocol as a reverse bits For example if the number hexadecimal is 34 65 89 32 which is represented in binary code as 00110100 01100101 10001001 00110010 154 AxTraxNG Software Installation and User Manual Adding Custom Wiegand Formats SECURITY PRODUCTS then in reversed bits format it is 4C 91
65. TraxNG software Refer to the AC 215 AC 225 AC 425 or AC 525 hardware manuals for wiring and installation instructions The manual explains the following in detail How to install the AxTraxNG server How to install the AxTraxNG client The basic functionality of AxTraxNG How to set up a new site from the AxTraxNG How to monitor and manage a site using the AxTraxNG client AxTraxNG Software Installation and User Manual 13 Specifications and Requirements 2 Specifications and Requirements 2 1 System Capabilities General Software Architecture Database Type Max Number of Users Max Access Groups Max Number of Time Zones Max Cards per User Max Number of Doors Max Access Control Panels Antipassback International Holiday Support Networks Max Number of Networks Supported Access Control Panel Models Panel Networks Communication Interface Communication Speed Client Server SQL Server Express 2005 2008 e 30 000 per panel AC225 AC425 AC525 e 5000 AC215 Based on the maximum number of users 30 000 x the number of panels 32 15 8184 1023 e Timed e Door e Global across the entire facility Up to 64 holidays Unlimited e AC 215 e AC 215 SPV e AC 215IP e AC 225 e AC 225 with MD l084 e AC 225 with MD DO2 e AC 425 e AC 425 with MD l084 e AC 425 with MD D04 e AC 525 e AC 525 with MD lO084 e AC 525 with MD DO2 e Serial RS 232 485
66. TraxNG Camera AC 5254002 AC 5254003 d Select the Attached to AxTraxNG checkbox next to the camera you wish to add to the system e Click OK 5 Set the camera properties in the AxTraxNG application a In the Tree View click AC Networks b Expand a network and select a panel to configure c On the toolbar click the panel s Be icon The available cameras are listed in the display area d Select a camera row e On the toolbar click the F icon The Camera Properties window appears 6 Set the camera s time zone and daylight savings behavior from the Camera screen in the AxTraxNG application Step 1 a Inthe Camera Properties screen click the 7 me tab b Select the local Time Zone trom the dropdown list c If Daylight Saving Time is now active select the Enable Daylight Saving Time checkbox This advances the local time selected by 1 hour d Click Apply or OK Daylight savings is currently not updated automatically by Windows It is therefore the user s responsibility to enable or disable the daylight saving time checkbox as necessary Note 7 Set the camera s time zone and daylight savings behavior from the Camera screen in the AxTraxNG application Step 2 a In the Tree menu double click a Panel item and Select the Options tab b In the Time Zone section define the time zone and Daylight Saving Time to match that of the Camera properties from Step 6 AxTraxNG Software Installatio
67. ab AxTraxNG Software Installation and User Manual 129 Firewall Configuration Windows Firewall General Exceptions Advanced Windows Firewall is blocking incoming network connections except for the programs and services selected below Adding exceptions allows some programs to work better but might increase your security risk Programs and Services Name 71004_C Application Sharing AS IPO1 Configuration Utility AxTrax Bonjour DHCP Discovery Service DigiOp RemoteManager Application DigiT ool Call Center File and Printer Sharing ftpcomm LMA Intellinent IP Installer Display a notification when Windows Firewall blocks a program v What are the risks of allowing exceptions x Coes 5 Click Add Program The Add a Program dialog appears Add a Program To allow communications with a program by adding it to the Exceptions list select the program or click Browse to search for one that is not listed Programs ia Solitaire amp Spider Solitaire SQL Server Error and Usage Reporting SQL Server Surface Area Configuration TransferUserD ata UD Agent mi Uninstall TD Uninstall DeepBurner bel Winlmage Bow Path C Program Files Rosslare VeritraxSQL VeriT re 6 Click Browse The Browse dialog appears 7 Inthe File Name box type C Program Files Microsoft SQL Server MSSQL 1 MSSQL BINN sqlservr exe and click Open
68. ach panel has individual antipassback settings for door antipassback behavior 5 Set the Antipassback behavior according to the field descriptions in the table AxTraxNG Software Installation and User Manual 51 Setting Up a Site 6 Click the Options tab Panel properties General Antipassback Options Events filter Select reported events Full upload Re upload all events from panel memory Door Interlock C Door 1 C Door 2 User Counter on re enable the panel Set new counter 7 Set the event filtering options for this panel 8 Click OK The window closes and the configured panel is displayed 5 5 Configuring the Doors Each panel controls one to eight doors Each door can be configured individually The Door Properties window displays the following The settings for unlocking and relocking The time available before the door relocks or records alarm events Details Description Auto r lock 1 FPanel 4 4Door 1 On door monitor closed REX enabled First person delay on automatic unlock Manual door open enabled C Door output polarity is Normally Closed Timers Door open time min sec Extended door open time rin sec Door held open L z min sec Door forced open F oo 4 rain sec 52 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS The Door Properties window contains the following fields Table 8 Network gt Panel gt Doors gt
69. anual 137 Network Configuration Modem status Network Phone number Status Network 4 544656931 Disconnected 245678546 Disconnected 3 To prevent access to AxTraxNG data from non authorized users the AC 215 AC 225 AC 425 or AC 525 access control panels contain a password that can be changed only when the modem is connected and there is a link with the panel You may be asked to enter the password during first data configuration such as adding a new panel or downloading a new firmware Confirm modem password Change password Current password Confirm password 138 AxTraxNG Software Installation and User Manual Restoring Factory Default Settings SECURITY PRODUCTS D Restoring Factory Default Settings If the modem configuration password is lost or forgotten reset the access control panel to the factory default settings and use the default VeriTrax password m Restoring factory default settings resets all doors and reader configurations to their factory defaults and clears all user properties To restore the factory default settings 1 Turn off the supply power 2 Disconnect all doors and readers wiring 3 Connect Data 0 Data 1 and Tamper inputs to GND in both reader 1 and 2 total of six wires 4 Power up the supply power for a few seconds Wait for the LED3 and LED4 LEDs to flash alternately 5 Turn off the supply power Connect the doors and readers wiring again 7 In AxTraxNG
70. any purpose without the express written permission of ROSSLARE ROSSLARE owns patents and patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give that party or any third party any license to these patents trademarks copyrights or other intellectual property rights except as expressly provided in any written agreement of ROSSLARE ROSSLARE reserves the right to revise and change this document at any time without being obliged to announce such revisions or changes beforehand or after the fact Table of Contents etre yee Table of Contents 1 MVE OCU COLON oi oisss fesse cece cceseciccceceesect asec viedesedessetsccteesensnts 11 1 1 System Features cccccccceeesseecsseesseeseuecnacesseeseeecnseecseeeesecnereeneeeseeees 11 1 1 1 ACESS COMTO sscecanevowecnsevansenumennncndeveediucnvenedudareateuwerentsudersadaucevenedudoneaseriagdd 11 11 2 Access MOntONN Oeste arses ccndneceneansneaascocntaesnts NE RENEE RETEA E N RETA A RE EEEREN E 12 1 1 3 SON E ECU e E E E 12 12 AxTraxNG Server and Client siasentwsdadsstccdnsuetwededgei
71. ard users can design their custom reports to meet their specific needs 1 1 3 Software Security Access to the AxTraxNG software is password controlled It is possible to grant individually based restricted security rights for different operators with access to only specified elements of the system or with read only access 1 2 AxTraxNG Server and Client The AxTraxNG system includes both the AxTraxNG Server and the AxTraxNG Client software applications separately Install the AxTraxNG Server on the computer that controls the access control panels and manages the database Install the AxTraxNG client software on any PC from which you wish to access the system One AxTraxNG server can serve an unlimited number of AxTraxNG clients AxTraxNG is based on a standard Client Server architecture Only the server connects to the database the clients draw the information trom the server Clients connect to the server using Serial communication RS 485 or LAN remote communication technology The server runs as a Windows service by default The client software is based on dynamic docking technology It is highly recommended that you back up the system database to an external storage device once a week see Section 11 4 12 AxTraxNG Software Installation and User Manual Introduction ees 1 3 Using this User Guide This user guide provides all the information required to start working with Ax
72. arious tabs as explained in detail in the user subsections 5 Click OK The window closes and the added visitor is displayed Users may be moved to other department or redefined as a Visitor A visitor may be moved into any department and changed to a regular user These can be done by using the General tab and selecting the new department to which you wish to the user or visitor 5 14 Adding Access Areas A large site can be divided into several smaller more manageable access areas Reports can be produced individually for each area In addition global Antipassback rules can be applied for each access area When global Antipassback rules are in effect users cannot re enter an access area until they have left it Use the Access Area window to add entry and exit door readers to and from an area within the facility To add an access area 1 In the Tree View expand the Groups element 2 Expand the Access Areas element and select Global AxTraxNG Software Installation and User Manual 77 Setting Up a Site 3 On the toolbar click the icon The Add Access Area window opens Insert Access Area Description Access Area 1 1 Available Readers To Enter Selected Readers To Enter 1 Panel 1 Reader 1 1 Panel 1 Reader 2 1 Panel 2 Rieader 1 1 Panel 2 Reader 2 Available Readers To Exit Selected Readers To Exit 1 Panel 1 Reader 1 1 Panel 1 Reader 2 1 Panel 2 Reader 1 1 Panel 2 Reader 2
73. art from the pop up menu 17 Right click SQL Server Browser and click Restart from the pop up menu The Firewall is now configured for AxTraxNG 132 AxTraxNG Software Installation and User Manual SQL Service Settings SECURITY PRODUCTS B SQL Service Settings 1 To reach the SQL Service Settings click the following path trom the Control Panel in Windows XP Control Panel gt Administrative Tools gt Services and Applications gt Services gt SQL Server VERITRAX 2 Double click SQL Service VERITRAX the following dialog opens SQL Server VERITRAX Properties Local Computer General Log On Recovery Dependencies Service name MSSQL VERITRAX Display name SQL Server VERITRAX Description Provides storage processing and controlled access of is data and rapid transaction processing Path to executable C Program Files Microsoft SQL Server MSSQL 1 MSSQL Binn sqlservr exe s Startup type Automatic v Service status Started You can specify the start parameters that apply when you start the service from here 3 Under the General tab verify that the Startup type is Automatic and that the Service status is Started SQL Server VERITRAX Properties Local Computer IX General Log On Recovery Dependencies Log on as Fi Allow service to interact with desktop O This account You can enable or disable this service for the hardware profiles listed below
74. assewamassineasmeancncadensapuciedgenant 86 6 2 Adding a Camera to the AC 525 Panel ccccccceccceeeecceeeeeeeeeeeees 88 6 3 Linking a Camera TO AX TAX cccasnanscsninunswcesiedsansnsniedendus caudanunan dasiedanesnenns 88 6 4 Conditioned Recording via Panel LINKS cccccecccceeseeeeceeeaeeeeeenans 91 65 Viewing Recorded Events coiutetastticadesdtesbadde teudedestusadaciicesdteandeednudadas cons 91 6 6 Automated ViTrax Camera Activation Options ssssiissssrireeerrnnn 94 AxTraxNG Software Installation and User Manual V Table of Contents 6 6 1 Reader A CES Sistine lasinatinnaiarniad wlan E A EA 94 6 6 2 eS EAE SA E EE EE D E EE OEE E OE EEPE DT T 95 6 6 3 Camer EVEN Ena aana A O 95 6 6 4 Door VV ANION VCMT osa peer 05 rans beaten EE oases av A A E has 96 7 Card Design Photo ID c1 csccscesenseecesenseeseeensenseeensenes 97 7 1 Creating a Card Template sisi ccinencicthaeds cenit vecwetierad noid uathessll exctdituoednn ditaerade 97 T2 PARMO Sel C a E A 99 8 Intrusion integration ccceceseeeeeeeseeenseeeneeeeneeeeeeneeeenes 105 8 1 Adding an HOX Panel sariti an nR 105 8 2 Serting Pane TINE en ons nateuieansae eats Mala tates rata 106 8 3 OG AU MC TI AN eaea a E a a a d 106 8 4 Downloading from the HLX Ranel cucccctostncds an ceastnwoncueectesinea anes 107 8 5 EARO TLA Se CUNO carie EE iecn alan 108 8 6 Uploading to the HLX Panel occ ccctine teen aha a eee vieecaes 108 8 7 Ewe Sytem VIEW iaia a
75. atus is displayed The ViTrax server now appears in the W 7rax Servers window list ilrax Servers IP Adress User Name Status SOFIA admin Connected AxTraxNG Software Installation and User Manual 87 ViTrax Video Integration 6 2 Adding a Camera to the AC 525 Panel Once a camera is physically installed the system reads the camera on the network and displays it in the tree Defining communication of AC 525 cameras to the ViTrax server is performed physically between the camera and the AC 525 panel see the AC 525 Hardware Installation Manual To view and add a camera to an AC 525 panel 1 In the Tree View click AC Networks The available networks are listed in the display area 2 Select a network 3 On the toolbar click the Es icon The Cameras window opens Location Description Attached to AxTraxNG Camera AC 525 002 AC 525 003 4 Select the Attached to AxTraxNG checkbox next to the camera you wish to add to the system 5 Click OK For a detailed description of how to add a camera to the AC 525 panels as detined both in AxTraxNG and ViTrax applications see Appendix E 6 3 Linking a Camera to AxTrax When a camera is linked to AxTrax video events can be linked to access control events and vice versa To link a camera to AxTrax 1 In the Tree View select the Camera element 2 On the toolbar click the Fs icon A window opens showing all available IP not AC 525 cameras
76. axNG application To add a camera to the system 1 Install the AC 525 panel and connect the cameras see AC 525 installation manual 2 Add the camera in the ViTrax application by either a Performing a camera search using the Automatically discover network devices option b Manually add a camera using the Camera setup wizard gt Add new device AC 525 3 Optional Configure Motion Detection in the ViTrax application if motion detection is used If Motion Detection is required first define Motion analysis via the ViTrax application a Select the Use Motion Detector for the Stream Being Used checkbox b Click Properties to adjust motion detection properties The Motion Detection feature consumes a large amount of CPU power resulting in a high overall CPU power usage by the application This may reduce the overall number of cameras that can be managed by the ViTrax Server application 4 Add the camera in the AxTraxNG application a In AxTraxNG ensure that the ViTrax Server is configured and is Connected with AxTraxNG b Inthe AxTraxNG Tree menu select the relevant AC 525 Network item c On the toolbar click the Bos icon On the left you see the names of the cameras connected with this network as previously defined in ViTrax 142 AxTraxNG Software Installation and User Manual Cross Platform Camera Setup SECURITY PRODUCTS Location Description Attached to Ax
77. c cstvedesdediediteasseues 12 1 3 Using this User CIA ssessrrrocrspurgnacrine peniagaan iais 13 2 Specifications and Requirement s ccscsscssssssesesseeeeees 14 2 1 System eat Ill les ax canceoecnescientencnesagenane sara ar RET a a 14 ZZ SYSTEM REQUIFEMENKS ccccccceeeccceeeeeeceueeeeeseeceeeaeeeeesueeeeeeaeeseeeaeeses 15 2 2 1 AxTraxNG Server and Client Requirement s sssinesinesrinesirrsrrrerrrrerrn 15 PP SQL Express Server Requirements cccccceececeeeeeeeeeeeeeeeeeeeeeeeeeaneeeeaneeeaneees 15 2 2 3 HASP USB Key Requirements cccccccceccecee cece se eeeeseeeeeseeeeeseeeeeaeeseesneeeeags 15 3 Installation cccceeceseeeeeeeeeeeeeseeeeeeaseeeeeenseeeeeenssaeeneeeensones 16 3 1 Choo smg an SOL SENET snusa E ia 16 3 2 Preparing the AxTraxNG Installation cccccccccccsseececeeeseeeeeeeaneees 16 3 3 Installing AxTraxNG Client Software eeessssiiineessrrrireeeersrrnnn 18 34 FU DEVICE DIVET rroen e R a 20 Eie Installing AxTraxNG Network Server Software 0 0 ccccccceeeeeeeeee eens 22 3 6 Installing AxTraxNG Watchdog sssnnnsssinnsssrrinnesrrrrssrrrrrrsrrrreen 25 3 7 Video Enhancement for AC 525 S tup cccccccccccccsceeccceceeessseeeeeeeeees 27 3 8 Firewall Setting S woca cians searcuacoterenceersanntdeutaunaunea aaa a aana aaan 28 3 9 SOL Server SE THINGS orrendi dipesan ioiai 28 4 System Overview s sssssssnsnsn1suuu
78. cepts cards only PIN Only The reader accepts PIN inputs only Card or PIN The reader accepts both cards and PINs Desktop The reader is inactive but can record new cards for the AxTraxNG database Secure Card PIN The reader requires first a card and then a PIN The PIN must be entered within 10 seconds of the card No Access The reader does not grant access to users To change the reader mode manually 1 In the Tree View expand the Networks element and expand a selected network 2 Select a panel 3 On the toolbar click the M icon The Manual Reader Operation window opens Manual Operations Reader Options Change operation mode Default V 1 Panel 3 Reader 1 Select All V 1 Panel 3 Reader 2 AxTraxNG Software Installation and User Manual 115 Manual Operation 4 Select an option Change operation mode Resets all selected readers to the selected operation mode Default Returns control of the readers to the system 5 Select the checkboxes of those readers to which to apply the operation 6 Click OK For more information on secured Card PIN time zones see Section 5 6 1 Note 9 3 Controlling Outputs Manually The Manual Output Operation window allows an operator to open or close a selected group of outputs on a panel directly To manually open or close an output 1 Inthe Tree View expand the Networks element and expand a selected network 2 Select a panel
79. d User Manual Network Configuration SECURITY PRODUCTS To initialize and configure the remote modem 1 In the Modem Configuration window click the Remote modem tab Modem configuration EEAS Naon ESSENIS IIs Iss soso ST PC modem Remote modem Settings Initialization string Use default Number of dial attempts 1 lt Apply 2 Inthe Settings area the initialization string is displayed in the window For most applications the default initialization string of is sufficient 3 Clear the Use default checkbox to allow adding or editing of the dialing string Then type the AT command in the Dialing string window 4 In Number of rings to answer set the number of rings before the computer modem answers 5 Connect the remote modem to the computer via the selected com port and click Apply to initialize the computer modem Click OK to initialize 7 Ifa failure message appears check the modem connections and repeat the last steps You must perform the action twice at the PC side to Initialize two MD N33s The MD N33 and AxTraxNG software are now configured and ready You can now continue working using the AxTraxNG Adding New Panel procedure To check the remote modem status 1 When a panel is setting in a modem network you can see the status of the modem by clicking the phone icon in the toolbar 2 There is a manual option to dial or disconnect the modem AxTraxNG Software Installation and User M
80. dditional users 8 Click Print to print a card 104 AxTraxNG Software Installation and User Manual Intrusion Integration SECURITY PRODUCTS 8 Intrusion Integration The intrusion integration allows you to integrate the intrusion panel into the AxTraxNG access control management software and to manage the intrusion panel when available In addition the integration creates logical event links between the software and the access control system 8 1 Adding an HLX Panel To add an HLX panel 1 Check that the HLX panel is connected to the PC 2 Inthe Tree View click HomeLogiX 3 On the toolbar click the SF icon The HLX Pane window opens Panel Information ba HL panel type Date format eee OO Me 7 w Communication type Firmware version Time format Serial Communication Panel Database Version Owner Information Hame E Phone Mobile Phone Po Address From the Communication type dropdown choose Serial or TCP IP 5 In Serial Communication choose the com port and the baud rate The new panel appears in the Tree View AxTraxNG Software Installation and User Manual 105 Intrusion Integration Hierarchic View C AxTraxNG L AC Networks E t g H HomeLagiz H HLY 1 Once you have added a new HLX panel you can begin to configure it 8 2 Setting Panel Time To set panel time 1 In the Tree View select the HLX panel 2 On the toolbar click the icon 3 The Set Time window opens
81. defined protocol This bit makes the total number of related bits an odd number The Even Parity bits in the protocol are represented with O and all the bits that they verify are represented with 1 CheckSum The number of bits usually 8 provides the sum of the previous bytes Checksum bits in the protocol are represented with S and all the bits that they verify are represented with 1 CheckXor The number of bits usually 8 provides a logical XOR value of the sum of the previous bytes CheckxXor bits in the protocol are represented with X and all the bits that they verity are represented with 1 AxTraxNG Software Installation and User Manual 155 Adding Custom Wiegand Formats J 4 Creating New Rules Using the above principles we can create new rules for AxTraxNG To create a new rule 1 2 3 NOW In the Tree View click AC Networks Click EJ icon The Reader Type window opens Reader Type Description Clock and Data Wiegand 35 Bits Wiegand 37 Bits Wiegand 32 Bits Wiegand 32 Bits Reversed Wiegand 34 Bits Wiegand 40 Bits Wiegand 40 PCSC Bits Wiegand 64 Bits Wiegand 37 Bits 10bit FC 16bit ID Clock and Data 6 digits Wiegand 37 long ID 16bit FC 19bit ID Wiegand 37 Rosslare Wiegand 37 AWID Click the F icon The Custom Reader Settings window opens Custom Reader Sett
82. deo integration make sure to a install it on every client PC as well as on the server PC Note 5 Click Start AxTraxNG Software Installation and User Manual 17 Installation Note If the AxTraxNG Server or Client setup detects a previous version of AxTraxNG a prompt appears asking if you want to upgrade AxTraxNG to the newer version Upgrading to a newer version only uses current database information After upgrading the AxTraxNG version check the panel s firmware version for both old and new installations and upgrade your firmware if required If there is no SQL server installed the Installation Requirements screen opens Installation of the two prerequisite applications begins Crystal Reports Basic Runtime for Visual Studio 2008 Please wat while Windows configures Crystal Reports Basic RT Runtime for Visual Studio 2005 Gathering required information E Microsoft Visual C 2005 SP1 Redistributabl E O X Please read the following license agreement Press the PAGE DOWN key to see the rest of the agreement MICROSOFT SOFTWARE LICENSE TERMS a MICROSOFT VISUAL C 2005 RUNTIME LIBRARIES These license terms are an agreement between Microsoft Corporation or based on where vou live one of its affiliates and you Please read them They apply to the software named above which includes the media on which you recenved it if any The terme also apply to any Microsoft updates s
83. dow options select either Manually or By timer 6 Click OK 6 6 4 Door Warning Event Create a door warning event based automatic camera activation The available door warnings in the system are Door held open and Door forced open To create door warning event based camera activation 1 Open the Door window see Section 5 5 2 Select the Door held open and or the Door forced open options and define their associated timer The Enable Cameras Options by Door Warning Events pane opens within the Door window Details Enable Cameras options by Door Warnning events Description Auto relock Camera On door monitor closed Camera A REX enabled Options C Eirst person delay on automatic unlock Pop up Live video window Manual door open enabled PC C Door output polarity is Normally Closed Popup Enabled Timers Close window options Door open time min sec O Manually Extended door open time min sec By timer 0 04 min sec Door held open min sec Door forced open min sec Select a camera from the Camera List Select a video option from the Options list Enable local pop up messages by checking the Popup Enabled checkbox Under C ose window options select either Manually or By timer Click OK Oo E E 96 AxTraxNG Software Installation and User Manual Card Design Photo ID SECURITY PRODUCTS 7 Card Design Photo ID AxTraxNG allows you to design badges for mass printing and supports connectivity with
84. ds Table 10 Network gt Panel gt Readers gt Reader Properties gt Options Tab Field Description Automatic Select whether to apply antipassback rules Antipassback To set Time Zones see Section 5 1 Hard When hard antipassback is selected an event is generated and the door does not open Soft When soft antipassback is selected the door opens but an event is generated Time Set the number of minutes before a user can reenter using this reader Facility Codes Click and type the facility code between 0 255 Up to four different facility codes can be entered 56 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 5 6 3 Access Event The Access event tab in the Reader window defines the alerts pop up windows behavior on the local PC General Options Access event Enable pop up user window by events PC AG C Access Granted C Access Denied Manually C Access Recorded By timer Enable Cameras options by events C Access Granted C Access Denied Sepa Enea C Access Recorded Camera Options By timer oor Pop up Live video window vw It contains the following fields Table 11 Network gt Panel gt Readers gt Reader Properties gt Access Event Tab Field Description Access Granted Mark to checkbox to enable a pop up window for Access Granted event type alerts Access Denied Mark to checkbox to enable a pop up window for Access Denied event type alerts Acce
85. e EE HE EE SF Name All Events Online Panels AC Access Alarm Archive System Panels HLX Cameras Pause Refresh View Events within the last Hour View Events within the last Day View Events within the last Week View Periodical Events View All Events Clear Show User Clear Alarm Click icon to Display all real time events Display all event types uploaded from the access control units Display only access events uploaded from access control units Display only alarm events uploaded from access control units Display video stream archive events stored in either the ViTrax database the USB key or snapshots saved on PC Display events related to the AxTraxNG Server operation and operators activity Displays events from the HomeLogixX panel Displays events recorded streams from a camera Halt the display of events in the display area New events are shown again when the Pause button is clicked a second time Manually refresh the event list Display all events that occurred within the last hour Click the dropdown arrow to change the view Display all events that occurred within the last day Display all events that occurred within the last week Display all events that occurred within a selected period Display all events Clear the entire log and empty the current event list view Open the User window for the selected user Open the A arm Details window to allow t
86. e the antipassback severity e Hard When hard Antipassback is selected an event is generated and the door does not open e Soft When soft Antipassback is selected an event is generated and the door opens In Out reader list From the IN OUT readers list select the checkboxes to apply Antipassback restrictions to Reader 1 through Reader 8 as required The reader antipassback is enabled when the checkbox is selected The Options tab contains the following fields Table 7 Network gt Panel Properties gt Options Tab Field Description Events filter Click Select to open the Events Filter and select the events that this panel should record Set the filter s operation method e Always Active Only the selected events are recorded by the panel e Active when panel disconnected If the panel is disconnected from the AxTraxNG server only the selected events are recorded When the panel is connected to the server all events are recorded Note In the default configuration some events are filtered and may not be seen in the display area Events view Door Interlock Select the Enabled checkbox to enable Door Interlock Select the Door 1 8 checkboxes to apply the Door Interlock restrictions to Doors 1 8 The Door Interlock function is only enabled when the Enable checkboxes and a minimum of two doors are selected AC 525 USB From the Alarm Threshold Range dropdown menu select Storage the percentage of available m
87. ed when the Get connection string from server checkbox is cleared To send an Error Log report 1 Click the Error Log Sending topic The Error Log Sending screen is displayed Common Info M Hardware Configuration M Operating System M List of Users I List of Installed Programs M List of SQL Servers DB Connection Restart Server O x IV Ping Networks V Get connection string from server Sender Notes Email Company Name Problem 2 Select the relevant checkboxes 3 In the Sender section fill out the necessary fields 4 Click Send AxTraxNG Software Installation and User Manual t31 AxTrax NET Watchdog 1 3 DB Connection This feature allows you to change the database connection string The DB connection window contains following fields Table 28 Watchdog gt DB Connection Screen Database Database name Server DB Server path Integrated security checkbox Select this option to sends username and password of database Username Database username Password Database Password To change the DB connection settings 1 Click the DB Connection topic 2 Enter the administrator password and click OK The DB Connection screen is displayed o x Common Info Database Error Log Sending ate DB Connection Restart Server Server local Weritrax Tv Integrated Security Username Password 3 Change the field parameter
88. el 2 Door 2 LIE 2 Panel 2 0utput 24 New 6 Select the checkboxes of all relevant outputs You can also use Select All and Select None 7 Click OK The window closes and the new output group appears in the display area 5 10 4 Defining Card Card Groups Card Card mode is a secure mode that requires two card holders users to grant access to a particular reader This feature is only available to Access Control panels AC 225 AC 425 and AC 525 Note 66 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 5 10 4 1 Adding a Card Card Group First you must add a Card Card group To add a Card Card group 1 In the Tree View pane expand the Groups element 2 Select Card Card Groups 3 On the toolbar click the F icon The Outout Group window opens Card Card Group Description Card Card Group 1 Inthe Description field enter a name for the input group 5 Click OK The window closes and the new Card Card group appears in the display area 5 10 4 2 Adding Users to a Card Card Group Once a Card Card group is created you must add users to It To add users to a Card Card group 1 In the Tree View expand the Departments Users element and select a department that contains the users you wish to add to the Card Card group 2 Select a user in the Table View area 3 On the toolbar click the icon In the General Tab of the User
89. el 3 Door REX CA 1 Panel 3 Door Monitor 4 1 Panel 3 Spare Input 2 CJA 1 Panel 3 Spare Input 24 By Network 2 2 Panel 2 2 2 Panel 2 Door 1 REX 4 2 Panel 2 Door 1 Monitor C 4 2 Panel 2 Door 2 REX A 2 Panel 2 Door 2 Monitor 6 Select the checkboxes of all relevant inputs You can also use Select All and Select None 7 Click OK The window closes and the new input group appears in the display area 5 10 3 Adding Output Groups Output groups are a collection of outputs from panel that can be used in panel links to perform advanced operations such as elevator control To add an output group 1 In the Tree View pane expand the Groups element AxTraxNG Software Installation and User Manual 65 Setting Up a Site 2 Select Outputs Groups 3 On the toolbar click the F icon The Outout Group window opens Output Group i Description Output Group 1 E I Network 1 Select All Select None BS Network 2 4 In the Description field enter a name for the input group 5 Expand a network to see its panels Output Group Destin Sh Network 1 Select All B E 1 Panel 2 LIE 1 Panel 2 Door 1 LIE 1 Panel 2 0utput 14 LIE 1 Panel 2 Door 2 CIE 1 Panel 2 Gutput 24 1 Panel 3 DE 1 Panel 3 Door OE 1 Panel 3 Qutput 14 DE 1 Panel 3 Qutput 2 LIE 1 Panel 3 Qutput 24 5 5 Network 2 2 Panel 2 LIE 2 Panel 2 Door 1 LIE 2 Panel 2 Output 14 DE 2 Pan
90. eld displays the current boot loader version Displays the input connections for the panel Displays the output connections for the panel Click to test if that the panel is correctly connected to the computer The Test Panel window displays hardware details including hardware type firmware and boot loader versions and indicates whether a reader or I O expansion board is installed on the panel AxTraxNG Software Installation and User Manual 47 Setting Up a Site Make sure that the DIP Switch 3 position on the panel corresponds with Its position demonstrated in the Pane properties window 4 Configure the panel according to the fields described in Table 4 5 Click Test The Hardware Test window opens with the complete panel details Hardware Firmware version ac225v04_01_01 Bootloader version btLac225y_01_02 Hardware AC 225 Supervised Inputs Yes Board None The test screen displays the following information Table 5 Hardware Test Screen Field Description Firmware version Displays the firmware version of the board a Displays the boot loader version of the board Hardware Displays the hardware name ea Displays the panel is secure in case of tampering MD 1084 Indicates whether or not MD 1084 exists MD D02 Indicates whether or not MD DO2 exists MD D04 Indicates whether or not MD D04 exists MD IPAV1 Displays the AC 525 Video board version number 6 Click Close The window closes and the display area displays the n
91. emory consumed to determine applicable when When the system generates the USB Disk Low Level event connected to AC The USB disk on key status is monitored roughly once an hour 525 only Therefore be sure to select an acceptably low threshold level and consider that any related alarm may be set off up to one minute after the actual event occurs Full Upload Click Start to re upload all events from panel memory Use the option only after consulting Rosslare s Technical Support Note A full upload can take up to 3 hours 50 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Field Description User Counter on re This option allows you to reset the user counter to its starting enable the panel value in the event that a panel is disconnected and then reconnected again This option is only visible when the Deduct User Counter checkbox is selected in the Genera tab of the Readers Properties window Section 5 6 1 To edit a panel 1 In the Tree View click AC Networks The available networks are listed in the display area 2 Expand a network 3 On the toolbar click the F icon The Panel Properties window appears 4 Click the Antioassback tab Panel properties General Antipassback Options Door Antipassback Automatic antipassback Never v Hard alarm and access denied Soft alarm only IN Readers OUT Readers C Reader 1 C Reader 2 C Reader 3 C Reader 4 E
92. enable this option Select the recording operation if needed Select what occurs when an event begins e Popup live video window e Show snapshot and save to archive e Recording Close Window Select how the window closes manually or by timer Options To add an HLX link 1 In the Tree View expand the HomeLogiX element 2 Expand an HLX panel 3 Select Links 4 On the toolbar click the SF icon The HLX Links window opens HL Event Link Destination Type e v Event Description Networks Network Network 1 Enabled 1 Fanel 1 AC Destination Type Outputs Destination T4Panel 10cor 7 Operation Timer Time m 22 04 Time one AxTraxNG Software Installation and User Manual 111 Intrusion Integration 5 Configure the link rule as required according to the field descriptions in Table 21 8 9 Linking an AC Panel to an HLX Panel Use this feature to link events from the access control system to the intrusion panel for example arming the intrusion panel while swiping a proximity card The AC HLX Link window contains the following fields Table 22 AC Networks gt Network gt Panel gt HLX Links gt AC HLX Link Window Field Description Source Type Select the panel component type door or reader Source Select the specific panel component that raises the event based on the source type selected Event Add a description of the event Destination Select the specific panel compon
93. ent which is to be activated by the link rule trigger event Operation Select the operation performed by the destination panel component To link an AC panel to an HLX panel 1 In the Tree View click AC Networks 2 Select a network and expand a panel in the Tree View 3 Select HLX Links A On the toolbar click the SF icon The AC HLX Link window opens AC HLX Link Source Type Destination next Source Operation Cancel Configure the link rule as required according to the field descriptions in Table 22 8 10 Arming HLX You can use a link to give a user a right to arm or disarm an HLX panel To give HLX rights 1 In the General Tab of the User Properties window Section 5 13 2 1 select the HLX Arm checkbox 112 AxTraxNG Software Installation and User Manual Intrusion Integration 2 Click OK AxTraxNG Software Installation and User Manual Si SSU Sie ie aaleleqrS 113 Manual Operation 9 Manual Operation In addition to AxTraxNG s automated access control network monitoring and control there is the option to manually control the network directly Door Manual Operation can only control doors that have been set as Manual Door Open Enabled in the Door Properties window see Section so gt Note 9 1 Controlling the Door Manually The Manual Door Operation window allows an operator to open or close a selected group of doors directly To manually open or close a d
94. eration and setup of the software 4 3 1 File Menu The File menu has three options Menu Select Menu item to Server Connection Log on to the AxTraxNG server ViTrax Server Log on to the ViTrax server Exit Exit the AxTraxNG software 4 3 2 Tools Menu Use the Tools menu to manage the database and set software preferences The menu has three options Menu Select Menu item to Database Open the Database window to back up the database or set a scheduled backup as well as to import or export the AxTraxNG and or VeriTrax AS 225 AxTrax AS 525 configuration states and events logs Options Set software options and preferences including national holidays event highlighting custom user information fields and GUI language Import Export Data Import export user information from to an Excel spreadsheet file AxTraxNG Software Installation and User Manual 31 System Overview 4 3 3 View Menu Use the View menu to define and manage the view of the GUI The menu has tour options Menu Select Menu item to Events Select the option to show event logs Table View Select the option to show a detailed table view Restore Docking Restore the default GUI view Close All Floating Close all pop up windows at once Windows 4 3 4 Window The Window menu has a special option In Corners to place any open pop up windows in the corners of the screen This option is chosen by default In Corners Tile Close All Floatin
95. ewly configured panel To search for existing panel on the network 1 In the Tree View expand the AC Networks element and select a network 2 On the toolbar click the icon The Find Panels window opens 48 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Find Panels Description Panel Type Panel Status Firmware Select All 4C 2 Not responding Select None Not responding Find Panels Add Panels 3 Click Find Panels to search for all connected panels in the network Once the detection process is complete this may take 2 3 minutes the display shows all of the detected panels and their corresponding information 4 Select the panels that you wish to activate and click Add Panels The selected panels then automatically appear in the Tree View under current network 5 4 3 Editing the Panel Each panel has individual settings for antipassback behavior and for recording events Once the panel is connected edit the panel s options from the Antioassback and Options tabs in the Panel properties window AxTraxNG Software Installation and User Manual 49 Setting Up a Site The Antipassback tab contains the following fields Table 6 Network gt Panel Properties gt Antipassback Tab Field Description Automatic From the Automatic Antipassback dropdown menu select Antipassback the time zone for door Antipassback rules to apply Antipassback severity Choos
96. ey dropdown select the desired option and click access events Select Color to display selected user information in a custom picked colored highlight Click Select Color adjacent to Unknown key to define the highlight color for unknown keys Show Select the checkbox to add a message to the event history upon download successful system parameters download from the AxTraxNG succeed software to the panel Hide foreign Select the checkbox to see only local administrator and AxTraxNG system events Server messages on this PC Select Holiday Click the button to select Microsoft Outlook holidays to load into AxTraxNG Use highlight Click Select Color adjacent to Network failed to define the highlight networks and color for network alarms panel status C ick Select Color adjacent to Pane not responding to define the highlight color for panel communication errors Language Select the system interface language Note Setting the language to Farsi also changes the date format to the Farsi date format 11 5 2 User Custom Fields The User Custom Fields tab controls the user defined fields on the User Fields tab of the User Properties window See Section 5 13 2 4 AxTraxNG Software Installation and User Manual 125 Administrator Operations User default valid time User Photo From DataBase 00 00 Extemal files Export from DB The User Custom Fields tab contains the following fields Table 25 Tools gt Optio
97. f doors accessed by this user Select the date time from when the user s access rights begin Select the date time on which the user s access rights end This field is only available when the checkbox is selected Select the checkbox to set an access rights countdown counter for this user see Appendix E When the counter reaches zero the user s access rights end Select the checkbox to set a new countdown counter value for this user see Appendix E Select a new countdown counter value for this user This field is only enabled when the Set new counter checkbox is selected Select the checkbox to override any Antipassback restrictions for this user Select the checkbox to entitle this user to an extended unlocked door duration The extended duration Is set for each door see Section 5 5 Gives the user the right to arm disarm an HLX panel see Section 8 10 Select the checkbox to activate a link rule initiated by access granted commands for this user see Section 5 9 Select the checkbox to activate a link rule initiated by access denied commands for this user see Section 5 9 Select an output group for this user The outputs are triggered every time the user accesses a door as specified in the Links window see Section 5 9 Select the checkbox to activate a dedicated output a short time after the door is unlocked see Section 5 9 73 Setting Up a Site 5 13 2 2 Codes Tab The Codes tab displays
98. fields see the HLX 40 Hardware Installation and Programming Manual for more details 8 8 Adding an HLX Link As with regular panels panel links are rules defining how the system should behave when events occur in the access control panel The HLX Links window contains the following fields Table 21 HomeLogiX gt HLX Panel gt Links gt HLX Links Field Description HLX Event Select the event Event Description Enter the event description Enabled Select the checkbox to enable the link rule Link Destination Select the panel component type which is to be activated by Type the link rule trigger event networks or cameras AC Destination Type Select the destination type e If Link Destination Type is Networks output or sounder e f Link Destination Type is Cameras cameras Destination Select the specific panel component which is to be activated by the link rule trigger event Operation Select the operation performed by the destination panel component 110 AxTraxNG Software Installation and User Manual Intrusion Integration Field Time Zone Networks Network Panel Time Camera Popup Video Enabled ViTrax Recording Camera Options SECURIT PRODUCTS Description Select the time zone for which the link rule applies Select the relevant network Select the relevant panel Define a duration timeframe for the operation This box is only available when a time bound operation is selected Select this checkbox to
99. figure the link as follows a In Source Type select Input b In Destination Type select Output Group c In Operation select Timer d Select the Generate Alarm checkbox 6 Click Alarm Handler The Alarm handler window opens 62 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Alarm handler PC SOFIA Message Popup Alarm Message C Popup Enabled Use highlight alarm event Fire Input Alarm Select Color C Open all Outputs of selected Output group Sound Select Wave Audio file 7 Configure the alarm handler as required according to the field descriptions in the table above 8 Select the Open all Outputs of selected Output group checkbox 9 Click OK to close the A arm handller window and return to the Add Link window 10 Click OK 5 10 Creating Groups You can create access groups and areas as well as input and output groups to be used by the system to create automated rules 5 10 1 Adding Access Groups An access group includes a list of door readers and the time zones during which each of those door readers are available for access Every user is assigned to an access group To add an access group 1 In the Tree View expand the Groups element and select Access Groups 2 On the toolbar click the F icon The Add Access Group window opens Access Group Description 3 In the Description field enter a name for the access group and click OK The ne
100. ftware Installation and User Manual Setting Up a Site SCE Ring reopens Panel properties General Antipassback Options Description Panel address 2 Panel 1 2 f g Enabled Type 2 Readers per door Hardware version AC 215 Input Input 1 Input 14 Input 2 Input 24 RN C Hide events on this PC 12345678 Firmware version Bootloader version Functions Output Door REX Door Monitor Spare Input 2 Spare Input 24 Functions Output 1 Door 1 Output 14 General purpose Output 2 General purpose Output 24 General purpose The Genera tab of the Door Controller Panel properties window contains the following fields Table 4 Door Controller gt Panel Properties gt General Tab Field Description Panel Address Enabled Hide events on this PC Type Hardware Version Firmware version Boot loader version Inputs Outputs Test Description Type a description for the panel Type an address number for the panel The network s address appears to the left of the panel address Valid entries are 1 32 Select the checkbox to activate this panel Clear the checkbox if the panel is not connected Select the checkbox to hide events originating from this PC Select one or two readers per door Select the appropriate panel hardware type Upon selection of the hardware version the field displays the current firmware version Upon selection of the hardware version the fi
101. g Windows Panel 1 Reader 1 30 04 2013 16 07 52 Panel 1 Reader 1 30 04 2013 16 07 55 2 Panel 1 Reader 1 30 04 2013 16 07 58 Panel 1 Reader 1 30 04 2015 16 08 00 Panel 1 Reader 1 30 04 2013 16 08 04 2 Panel 1 Reader 1 30 04 2015 16 08 06 2 Panel 1 Reader 1 30 04 2015 16 08 06 Panel 1 Reader 1 30 04 2015 16 08 07 2 Panel 1 Reader 1 30 04 2015 16 08 07 2 Panel 1 Reader 1 30 04 2013 16 08 09 Alternatively you can select the standard Tile option to move any opened pop up windows to available space on the screen In addition you can close all of these pop up windows by clicking Close All Floating Windows You can use the list of open pop ups to focus on any open pop up window 4 3 5 Help Menu The help menu has one option Menu Select menu item to About View software firmware and database version information as well as the current operator 32 AxTraxNG Software Installation and User Manual System Overview 4 4 Toolbar SECURITY PROD UCTS The toolbar controls key tasks required to manage access control across an entire facility When a new element is selected from the Tree View the toolbar icons change to suit the selected element The following toolbar icons are available 4 4 1 Icon 3 5 oe ol 4 4 2 Icon wie 4 4 3 Icon PEs AO General Icons Name Manual Door Operation Print Add Edit Delete Reader Type Click icon to Open the Door Manual Operation
102. grading the following screen opens AxTraxNG Watchdog 2 jJ This setup will perform an upgrade of AxTraxNG Watchdog Do you want to continue If you are Installing for the first time the following screen opens AxTraxNG Software Installation and User Manual 25 Installation ie AxTraxNG Watchdog InstallShield Wizard Welcome to the InstallShield Wizard for AxTraxNG Watchdog The InstallShield R Wizard will install AxTraxNG Watchdog on your computer To continue click Next WARNING This program is protected by copyright law and international treaties j Cancel To install the AxTraxNG Watchdog 1 Click Yes and or Next to begin the AxTraxNG Watchdog installation process 2 Click Next to initiate the AxTraxNG Watchdog installation process The Destination Folder screen opens i AxTraxNG Watchdog InstallShield Wizard Destination Folder Click Next to install to this folder or click Change to install to a different A Install 4xTraxNG Watchdog to C Program Files Rosslare AxTraxNG Watchdog InstallShield 3 Select the required installation location by clicking Browse or click Next to use the default destination The Ready to Install the Program screen opens 26 AxTraxNG Software Installation and User Manual l n sta ati O n SecURE eR iS AxTraxNG Watchdog InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation Click
103. gt Network gt Panel gt HLX Links gt AC HLX Link L113 6 011 EN ee een eet ane ene net Ot oe eae ete E 112 Tools gt Database gt Available Databases 0 cccccceecccceeteeeeeees 124 Tools gt Options gt General Tab cece ccccccceeccceceeseeeeeeeeseeeeeeees 125 Tools gt Options gt User Custom Fields Tab ccccceecccceeteeeeeeees 126 Tools gt Import Export Dae op crocoesntra cddinnusmcens nein slay bememean ids aesianemnonsns 127 Watchdog gt Error Log Sending Screen ccecccceeseeeecceeeeeeeeeees 150 Watchdog gt DB Connection Screen cccccceeecccceeeeeeeeeeesaeeeeees 152 AxTraxNG Software Installation and User Manual IX Notice and Disclaimer Notice and Disclaimer This manual s sole purpose is to assist installers and or users in the sate and efficient installation and usage of the system and or product and or software described herein BEFORE ATTEMPTING TO INSTALL AND OR USE THE SYSTEM THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES The system must not be used for purposes other than those for which it was designed The use of the software associated with the system and or product if applicable is subject to the terms of the license provided as part of the purchase documents ROSSLARE ENTERPRISES LIMITED and or its related companies and or subsidiaries hereafter
104. he operator to reset the alarm AxTraxNG Software Installation and User Manual 35 System Overview Icon Name Click icon to Antipassback Open the Antipassback Forgive window to allow the on i F ALD Forgive operator to cancel an Antipassback restriction for the selected user Ps Camera List Open a list of all ViTrax cameras attached to the Fs network Archive Open the Archive Camera window for the selected e video stream or snapshot mA Car Parking Opens the Car Parking Counters window to view and edit the car parking area and group counters 4 5 Tree View The Tree View allows users to configure monitor and control every aspect of a facility s access control network When the user selects an element from the Tree View its contents are shown in the main display area and the toolbar icons change to suit the selected element 4 5 1 AC Networks A network is a group of up to 32 access control panels The AxTraxNG Server connects to the panels across the panel network For more information see Section 5 3 To work with 65 panels or more a HASP security key must be connected to the AxTrax Server machine see Section 2 2 3 4 5 2 HomeLogiX The HomeLogiX element allows you to add HLX panels to the network and to configure each panel s settings For more information see Chapter 7 4 5 3 Cameras Cameras can be added to the network to allow real time viewing of any area desired The Camera element all
105. ick OK E 1 Resetting Counter on Panel Re enable There is an additional counter option that allows you to reset the user counter to its starting value in the event that a panel is disconnected and then reconnected again If this option is not used then upon panel re enable the user counter continues with its previous value prior to having that panel disabled To reset the user counter on panel re enable 1 In the Tree View expand the AC Networks element and select a network 2 From the Table View area select a panel 3 On the toolbar click the F icon The Panel Properties window opens 4 Click the Options tab 140 AxTraxNG Software Installation and User Manual Configuring User Counters SECURITY PRODUCTS 5 Select the Set new counter checkbox User Counter on re enable the panel Set new counter 6 Click OK AxTraxNG Software Installation and User Manual 141 Cross Platform Camera Setup F Cross Platform Camera Setup This section describes the complete process of adding cameras to the AC 525 panels as defined both in AxTraxNG and ViTrax applications as well as emphasizes some of the important steps to help ensure proper camera operation This process is essentially a two step procedure that needs to be defined in both applications First you need to add the installed camera in the ViTrax software only then is it possible to assign the camera to the relevant AC 525 panel defined in the AxTr
106. ick OK 5 Create output groups see Section 5 10 3 Each output group represents a floor or several floors When creating an output group for the elevator control the selection only applies to outputs from the same panel 6 Inthe General tab of the User window associate a user with the relevant output groups see Section 5 13 2 1 Each user can be associated with the relevant output groups to allow user access to specific floors as needed 7 Create a panel link see Section 5 9 Only one panel link is required 5 19 Creating Status Maps The Status Map displays the status of every door input and output antipassback rules and alarms in the facility on user selected floor plans To set up a Status Map 1 In the Tree View select Status Map 2 On the toolbar click the icon The Add Status Map window opens AxTraxNG Software Installation and User Manual 83 Setting Up a Site Ji Status Map Status Map 1 Save Close 3 Right click in the window and select Set background from the shortcut menu The Select Picture File window opens To change the map image and or to add objects on the map you must select 4 the Design Mode checkbox The Add Map icon in the toolbar is enabled Note 4 Select a graphic file omp jpg gif or tiff for the Status Map background 84 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 5
107. iguration to locate the hardware on the local network c Fora modem click Configuration to set dialing preferences for the computer s and the receiving modems For more information on how to configure an access control network see Appendix C Check with your system administrator for more information or contact Rosslare technical support Clear the Enabled checkbox if you want to halt communication to panels on the network Access control panels connect to a TCP IP network via MD N32 TCP IP to a serial converter or by using the on board module in AC 225IP AC 425IP or AC 525 Refer to the relevant hardware installation guides for more details 7 For all types of networks set the DIP switch on the access control panel hardware to match the diagram at the top of the screen After changing the DIP switch make sure to power down and then power up the panels 8 Inthe Add Network window click the Options tab AxTraxNG Software Installation and User Manual 43 Setting Up a Site 10 44 Panel network using AxTrax Server time zone Panel network using different time zone To use the time zone of the AxTraxNG Server for the panel network select Panel network using AxTraxNG Server time zone default and then continue to Step 12 To select a different time zone for the panel network select Panel network using different time zone The Network Time Zone area opens General Options
108. ings C Set as Default Enter a description of the new rule Choose the number of bits the new rule will use Optional Select the Set as Default checkbox In the Rules section enter the protocol rules according to the guidelines described in Sections J 1 through J 3 and as shown in the example below 156 AxTraxNG Software Installation and User Manual Adding Custom Wiegand Formats SECURITY PRODUCTS The protocol definition is for the entire system and not per controller Note Example Enter a new Wiegand 29 bit protocol with the following rules Rule 1 Bit 1 Odd parity on the bits 3 15 Rule 2 Bit 2 Even parity on the bits 16 28 Rule 3 Bit 29 Odd parity on the bits 1 28 Rule 4 Bits 11 28 ID data Rule 5 Bit 3 10 Facility code The new protocol appears in the Custom Reader Settings window Custom Reader Settings Description Wiegand 29 for example Number of bits 29 C Set as Default Bit 1 Odd Parity on Bits 3 to 15 a We aa the other bits are 0 0111111111111 1 00000000000000 0E000000000000011111111111110 lt lt Bit 2 Even Parity on Bits 16 to 28 141111111111111111111111111110 the other bits are 0 0000000000DDDDDDDDDDDDODDDDOT 00FFFFFFFF0000000000000000000 Bit 29 Odd Parity on Bits 1 to 28 aa the other bits are 0 Facility Bits 3 to 10 ID pa t e 28 ithe the other bits are 0 other bits are
109. ion Produces reports from acquired data such as entry and exit times as well as alarm types initiated by user location and time events Available in multiple languages and date formats Compatible with additional video management software modules from Rosslare ViTrax Backward compatibility with VeriTrax AS 225 and AxTrax AS 525 1 1 1 Access Control Access groups define access rights for every part of the site Access rights are time dependent for example users in the Mornings Only access group can have access to certain areas of the site between 9 am and 12 pm only Assign each individual user to an access group The system also stores an identification photograph and personal details for each user as well as user specific access settings such as antipassback AxTraxNG Software Installation and User Manual 11 Introduction immunity requirements for an extended open door period contigurable special privileges and triggered outputs 1 1 2 Access Monitoring The AxTraxNG software records every attempt to open a door within the site Status maps show the state of every part of a facility while an Events log records complete details of every time access is granted or denied for every door on a site and records possible door tampering and forced entries AxTraxNG can also produce a variety of access reports including usage reports attendance records and roll calls Using the AxTraxNG Report Wiz
110. ion Troubleshoot When installing the MS SQL Server 2005 Express component in a Windows Server 2003 or 2008 environment you might get the following error message 7he sa password must meet SQL Server password policy requirements This is because either The domain entforced policy is preventing the installer from setting the SA user s password or The local security policy is preventing the installer from setting the password You can temporarily disable this policy while the installation is running and click Retry to let the installation complete successfully After installation is finished you can restore the policy to the desired setting If you are on a Domain Controller check the Domain Controller security settings first ya Default Domain Controller Security Settings File Action View Help e om xX B ee Security Settings Poli etting S E Account Policies f 9 Enforce password history Not Defined EA Password Policy Rg Maximum password age Not Defined g a Account Lockout Policy 83 Minimum password age Not Defined 9 9 Kerberos Policy 83 Minimum password length Not Defined G a Local Policies Password must meet complexity requirements ex 9 mee Couns amp 2 Store passwords using reversible encryption Not Defined E G System Services a Registry H A File System F Wireless Network IEEE 802 11 f amp Public Key Policies E Software Restriction Policies H IP Security Policies on
111. ions add the _AxTrax1_vX prefix at the end of exported or backed up database The Import database function executes only with the string at the end of the file name After a database is imported the panel status may change to disabled If this occurs the operator should re enable the panels 11 5 AxTraxNG Options and Preferences AxTraxNG can be customized to meet the preferences of the operator using the Ootions window To open the Options window 1 From the menu bar select Tools gt Options 124 AxTraxNG Software Installation and User Manual Administrator Operations SECURITY PRODUCTS The Options window has two tabs General General startup and presentation settings User Custom Fields Additional user defined fields for the User Properties window 11 5 1 General Tab The General tab includes presentation connection settings General User Custom Fields Use highlight access events Use highlight Networks and Panel status Known key Network failed Select Color All users a Select Color Panel not responding Select Color Unknown key Select Color System events Language C Show download succeed es C Hide foreign system events on this PC Note On changing language you must restart AxTraxNG Server and Clients Holidays Select Holliday The Genera tab contains the following fields Table 24 Tools gt Options gt General Tab Field Description Use highlight From the Known K
112. itself Aladdin Cancel 20 AxTraxNG Software Installation and User Manual l n sta ati O n SecCURA eRODUSS To install the HASP device driver 1 Click Next to begin the installation process The End User License Agreement screen opens gal End User License Agreement ALADDIN KNOWLEDGE SYSTEMS LTD HASP Device Driver LICENSE AGREEMENT IMPORTANT INFORMATION PLEASE READ THIS AGREEMENT CAREFULLY BEFORE DOWNLOADING OR INSTALLING THE SOFTWARE PROGRAM ALL ORDERS FOR AND USE OF THE HASP Dewice Driver including any revisions corrections modifications enhancements updates and or upgrades y accept the license agreement Cancel 2 Accept the licensing agreement and click Install Installation of the driver begins Installing drivers ofl Please wait When the installation is complete the Driver installed successfully screen opens t HASP Device Drivers Driver installed successfully Aladdin 3 Click Finish to complete installing the HASP driver AxTraxNG Software Installation and User Manual Ji Installation 3 5 Installing AxTraxNG Network Server Software Following the HASP Device Driver installation the AxTraxNG Install Shield Wizard for the AxTraxNG Server software installation appears If there is no SQL server installed the Installation Requirements screen opens Click Install and follow the steps to install the SQL server i InstallShield Wizard
113. levant access area that you defined in Step 1 In the Checked by area perform one of the following a Select Access Area In Area maximum counter choose the number of parking spots available in that access area Click OK b Select User Groups 80 Click OK In the Tree View under Car Parking choose the car parking area you just created On the toolbar click the F icon The Car Parking Group window opens Car Parking Group Description Car Parking Group 1 Group maximum counter i zi In Description enter a name of the car parking sub group AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS V Vi vii viii xi xii xiii In Group maximum counter choose the number of parking spots available for the parking group Click OK In the Tree View expand the Departments Users element and select a department that contains the users you wish to add to the Car Parking sub group Select a user in the Table View area On the toolbar click the FF icon In the General Tab of the User Properties window see Section 5 13 2 1 select the Car Parking sub group from the Car Parking Group dropdown Click OK Repeat Steps viii and x for each user you wish to add to a particular Card Card group Repeat Steps iii to xii for each group that you wish to add to the car parking area 5 16 1 Viewing and Editing Car Parking Counters Once you set up y
114. mance Services kad Share this Folder Services Management ODBC Other Places E Control Panel My Documents Shared Documents Q My Computer My Network Places Details Administrative Tools System Folder 14 Double click Services The Services Console opens AxTraxNG Software Installation and User Manual 131 Firewall Configuration 3 Services File Action View Help m 2 ERa Services Local ASEA Local Windows Firewall Internet Name Description _ status amp Connection Sharing ICS Sa Themes Provides u Started Sa Uninterruptible Pow Manages a Bs Universal Plug and Provides s Sa Volume Shadow Copy Manages 4 Sy WebClient Enables Wi Started Provides network address translation Be Windows Audio Manages a Started addressing name resolution and or 2 Windows Firewall In Provides n intrusion prevention services for a home Ba windows Image Ac Provides im Started Stop the service Restart the service Description or small office network SRy Windows Installer Adds modi Ba windows Managem Providesa Started Sa Windows Time Maintains d Started Sy Wireless Zero Confi Provides a SRy WMI Performance A Provides p SRy Workstation Creates an Started lt N Extended 15 Right click Windows Firewall Internet Connection Sharing ICS and click Restart from the pop up menu 16 Right click SQL Server and click Rest
115. me ZOMG 2 ntccsticernducnisclonauascbat hd neu aPundnaitaabhit cide Amen esituonaavtetdendidiabnds 39 52 PACING TONG ay Sedne ingore tie te geonsteioee eG eeetoieaes 40 gro 2 8 011000 r NeEtWWOM aseina ene i a e a a a a 42 5 4 Adding Access Control Panels sssnnnusesinnuessinnnssrirrrrerrrrrrerrrrrrenn 45 5 4 1 General Panel Settings aa Pied etd A 46 5 4 2 Adding GP ANG sn fess entesh obs nud a Stable nda antobab a Reh eae 46 5 4 3 Edungine Paneli ea eree eee ee CR See ek eR meh cee er Sree nee 49 Sa COMMGUEIMG WNC OONS aigan a a scien ciantnadin 52 SO CONIUNGI INE RCIE anna 54 5 6 1 EEI EE EREE EES EE tos AEE EES AEE TEA ETE oes 54 56 2 Jado aks Bs 9 NAE EA nar mee re EEE oe Rei E AEE Sanne ae Ee Se E 55 IV AxTraxNG Software Installation and User Manual Table of Contents E 5 6 3 ACCESS EVON orrai eE EAE A E A T 57 S7 Configuring th NPU sea taredi dale te cule Maa dle dreenlinaiierie naina Ti a 58 56 AONA C AION seareiro innen aana aaa iein Enina a N 59 59 Adang Panel LINKS cs ctceaarngpaeesaaceens neccentenqeee desnarcenwuuendyenannaeaeaaeone 59 5 9 1 Creatng a Fire Alarm IMPUT sissisotaa aiii 62 5 10 Creating GrOUPS a esrsrsiricnie innaka nnns EEEn EAEE ENEE ANENE RAEAN 63 5 10 1 Adding Access GrOUDS ccccccccseccceeeeeeceeeeeeeeeeeseeeseeeeeeseesaeeeseesaeeeeeeeaaees 63 D102 Adding IND UT GODS 5 cciseniicessentacintsannndensenponnssdmdidedoundaseddimmadostoubadaduiededionts 64 S103 Adding Output IOUS essacessect
116. mera The automated camera activation turns on the camera and opens a video pop up and a snapshot window on the locally used PC in response to predefined events occurring in the system as described in the following sections 6 6 1 Reader Access Create reader access event based automatic camera activation on the local PC To create reader access camera activation 1 Open the Reader window see Section 5 6 2 Click the Access event tab General Options Access event Enable pop up user window by events PC SOFIA C Access Granted C Access Denied Manually C Access Recorded By timer Enable Cameras options by events Access Granted PC SOFIA C Access Denied Popup Enabled C Access Recorded Camera Close window options Camera A Manually Options By timer 004 a min sec L 3 Under Enable Camera options by events select the Access Granted Access Denied or Access Recorded checkbox Select a camera from the Camera dropdown 5 Select a video option from the Options dropdown Select the Popup Enabled checkbox to enable local pop up messages Pop up Live video window 94 AxTraxNG Software Installation and User Manual ViTrax Video Integration SECURITY PRODUCTS 7 Under Close window options select either Manually or By timer 8 Click OK 6 6 2 Alarm Event Create alarm handler event based automatic camera activation To create alarm handler camera activation 1 Open the
117. n 9 3 Change the settings for the inputs on the selected panel see Section 9 4 Test the siren for the selected panel see Section 9 5 Card Users Icons Name User Counter Add users Add cards Assign cards Print Cards User Filter Reports Icons Name Produce Report Print View Last Hour Access View Periodic Access Click icon to View the current user count value see Section 11 3 Create up to 1000 new users in one click Section 0 Create up to 1000 new cards in one click Section 0 Add and assign cards to selected users or add cards from MD 08 see Appendix G Print a card template that has been created see Chapter 7 Filter the list of users by various parameters such as name and card number see Section 4 5 8 3 Click icon to Produce the selected report Chapter 10 Send the current report to the printer Display relevant access events that occurred within the last hour Chapter 10 Note This icon appears only when a Roll Call Readers report is selected Displays relevant access events that occurred within a selected time frame Chapter 10 Note This icon appears only when a Roll Call Readers report is selected AxTraxNG Software Installation and User Manual System Overview 4 4 7 SECURITY PROD UCTS Events Toolbar Icons When clicking an event icon click the dropdown arrow to change the current view of the display Icon Lo i T Beb
118. n Publisher Type Application From C Documents and Settings sanc Desktop Always ask before opening this file publisher ou should only run software from publishers wou trust x This file does not have a valid digital signature that verifies its How carn decide what software bo tur 3 Click Run Once the various necessary files are extracted the following screen opens Figure 1 AxTraxNG Packages Selection Screen 4 amp xTraxNG Installation version 0 0 22 2 Software of any kind provided with or as part of the product is provided explicitly as is within an explicit denial of all warranties expressed or implied including without limitation warranties of merchantability non infringement or fitness for a particular purpose but nevertheless Rosslare guarantees that the software to be free from defects for a period of ninety 90 days after delivery If any defect appears within the warranty period you can contact Rosslare to receive replacement software free of charge at the discretion of Rosslare Rosslare does not warrant and has no responsibility for the accuracy or completeness of any information text graphics links or other items contained within the software C agree This screen remains opens in the background as various elements of the a software are installed Note 4 Accept the licensing agreement and choose which packages you wish to install When installing the ViTrax software for vi
119. n and User Manual 143 Cross Platform Camera Setup 8 144 Test time synchronization in both application a b In the Tree menu select your network On the toolbar click the icon and verify that the time matches the AxTraxNG s Server PC time Select the panel and click Apply 1 or 2 seconds difference is acceptable In the tree menu double click the icon and click Properties Click the 7 me tab and verity that it matches the AxTraxNG Server PC time If the ViTrax Server application and the AxTraxNG Server application are running on different PCs ensure that both of the PCs are synchronized It is advised that both PCs are assigned with the Same time server AxTraxNG Software Installation and User Manual Enrolling Cards using MD 08 Desktop Reader SECURITY PRODUCTS G Enrolling Cards using MD 08 Desktop Reader This option is available for users with the MD 08 unit on board To define the MD 08 1 Select Cards in the Tree View 2 Click the Insert card by MD 08 icon on the toolbar or click Add from MD 08 on the User form Codes tab The Add Cards from MD 08 window opens Add cards from MD 08 Card type Wiegand 26 Bits COM port mE x 3 Select the Card type and Com Port from the respective dropdown lists 4 Enroll cards using the reader 5 Click OK AxTraxNG Software Installation and User Manual 145 SQL Server Installation Troubleshoot H SQL Server Installat
120. n speed The type of network connection and the connection settings General Options Description Network 1 Enabled i 86 Network type 12345678 TCP IP E w TCP IP Network IP Address Port 192 168 20 1000 Speed RA t AN 9600 Remote WAN Local LAN The General tab contains the following fields Table 2 Add Network gt Options Tab Field Description Description Name for the network The network address appears to the right of the network name Enabled Checkbox is selected when the network is connected and operational Network Type Network type Serial TCP IP or Modem For TCP IP connection set the TCP IP network see Appendix C Configuration Configuration window to set communication preferences Button This button appears when selecting a Modem or TCP IP LAN network For more information see Appendix C To add a network 1 In the Tree view select Metworks 2 Expand the Networks element to view available networks 42 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS g E AxTraxMG a Networks h Network 1 3 On the toolbar click the F icon The Add Network window opens In Description enter a name for the new network 5 Select the Enabled checkbox In Network type select the network type and set the connection settings a For serial select the correct COM port b Fora TCP IP LAN click Conf
121. ns gt User Custom Fields Tab Field Description Field type Select the type of field If field type is list click Edit and enter list items Field description Type a name for the new field User default valid time Set default start and end time for user access rights using the From and Until fields User Photo Define the default photos to be used e Database Use the User photos save in the Data base e External files Use this option to save a large user photo collection external from the data base e Export from DB Click to export existing photos from the Data base to an external folder 11 6 Importing Exporting User Data The Import Export Data window makes it possible to import export user information into from the AxTraxNG database from to a standard spreadsheet file 126 AxTraxNG Software Installation and User Manual Administrator Operations Import Data SCE Ring PRODUCTS Import Users properties from external file into AxTraxNG Export Users properties from AxTraxNG into external file Excel file Location Data type Excel Workbook xls Excel file Columns C A User index field C B First name C C Last name C D Middle name C E Department C F Access group Started from Excel file Row 2 C G From Valid date C H Until Valid date C T Telephone C Y Mobile C K Fax C L Email Departments Import Departments Yes No
122. nstalled no license is required for that ViTrax Server To add cameras for AC 525 1 Activate the ViTrax Server and Client see Wi7rax Software Installation Manual Define ViTrax Servers see Section 6 1 Define communication of AC 525 cameras to the ViTrax Server see Section 6 2 4 Activate AxTraxNG and configure it see Chapters 4 and 5 3 8 Firewall Settings Internal firewall settings may prevent the AxTraxNG Server from connecting to the SQL database or to panel control units using TCP IP and remote Server Client connection For more information on how to configure a firewall see Appendix A Contact your system administrator or Rosslare Technical Support for further guidance 3 9 SQL Server Settings After installing AxTraxNG verify that the SQL server service on the computer is running and set to the required installation For more information on SQL server settings see Appendix B If SQL Express 2005 is being installed part of the installation package the installation must be on the same Windows user account that is being used for AxTraxNG 28 AxTraxNG Software Installation and User Manual System Overview SECURITY PRODUCTS 4 System Overview AxTraxNG is controlled through a user friendly interface and comes with a Tree View list of all aspects of the site setup and a toolbar for standard operations 4 1 Starting the Software This section explains how to start the
123. of the card 8 Right click on any field appearing in the card area to show the following menu options 98 AxTraxNG Software Installation and User Manual Card Design Photo ID SECURITY PRODUCTS Fort Background Transparent Lett Align Center Right Align Properties Delete 9 Select Properties to remove the border and change the field size First Name Border Position Size Top Height 0 854 Max 2 125 0 219 Max 2 125 Left Width Max 3 365 1 250 Max 3 365 10 Click OK to save the card template 7 2 Printing a Card Once you have save a card template you can print cards using the template To print a card 1 From the card template list in the Table View area click the icon The Print Card Selection window opens AxTraxNG Software Installation and User Manual 99 Card Design Photo ID The print card wizard will help you to print cards in a pre design card layout Choose printer from list ll crn asite ee You can press back at any time and change your selection Which card layout do you want to print 2 Select your printer from the dropdown and click Next The Print Card Users List screen opens 100 AxTraxNG Software Installation and User Manual Card Design Photo ID SECURE maleate Print Card Available General doe john 1234 doe john 4444 doe jane 5987 doe jane 4321
124. only active when the Ao option is selected in the Import Departments option Import Access Groups Select Yes to import new access groups into the AxTraxNG database Select No to import users without their access groups Access Groups Select the access group to assign to the imported users This box is only active when the Vo option is selected in the import access group option To open the Import Export Data window 1 From the menu bar select Tools gt Import Export Data 11 7 AxTrax GUI View Options The AxTraxNG Client main window GUI can be customized using the View menu ca Help wee Events Table View Restore Docking Close All Floating Windows Events to make Events window visible invisible Table View to make Table View visible invisible Restore docking to return to default GUI Setting Close all floating Windows to close all pop up windows 128 AxTraxNG Software Installation and User Manual Firewall Configuration SECURITY PRODUCTS A Firewall Configuration The following instructions explain how to configure the standard Windows Firewall for Windows XP To configure the firewall 1 Open the Control Panel on your computer Fie Edt wew Favorites Tools Hap Osx amp Pseach racers M Address B Coritrol Panel 4 Control Panel e Switch to Classic View See Also Windows Update Q Help and Support ther Control Panel Options wo Performance and Maintenance
125. oor 1 In the Tree View expand the Networks element and expand a selected network 2 Expand a panel and select Doors 3 On the toolbar click the icon The Manual Door Operation window opens Door manual operation Options Open momentarily closed by timer 0 04 min sec Open permanently closed by Close output and return to default mode Close output and return to default mode Description Details Select All o 1 Panel2 1 Panel 2 Door 1 Default a 1 Panel 2 1 Panel 2 Door 2 Default Re 1 Panel 3 1 Panel 3 Door Default j 2 Panel 2 2 Panel 2 Door 1 Default 3 2 Panel 2 2 Panel 2 Door 2 Default B 3 Panel 1 3 Panel 1 Door Default ro 4 Sort the listed panels doors in regular or reverse order by clicking the column header with the left mouse button 5 Select an option Open momentarily Open all selected doors for the time set in the timer box Open permanently Opens all selected doors Close output Closes all selected doors and returns control to AxTraxNG 114 AxTraxNG Software Installation and User Manual Manual Operation SECURITY PRODUCTS 6 Select the checkboxes of those doors to which to apply the operation 7 Click Apply 9 2 Changing the Reader Mode The Manual Reader Operation window allows an operator to change the operation mode of a reader Readers have six possible operation modes Inactive The reader is not in use Card Only The reader ac
126. our various car parking groups and areas these groups and areas can be easily viewed and edited To view and edit the Car Parking counters 1 In the Events toolbar above the Event Log area click the 2 icon The Car Parking Counters window opens Car Parking Counters Car Parking C Area maximum counter Area current counter Car Parking Groups Group maximum counter Group current counter sdsddf j C Set new counter C Set new counter 2 Update the maximum or current counters of either the car parking areas or the car parking groups depending on how the car parking element is defined The values of the maximum counters entered in this screen override the values of the maximum counters that you entered in Section 5 16 3 Click OK AxTraxNG Software Installation and User Manual 81 Setting Up a Site 5 17 Adding Operators Operators are people with access to the AxTraxNG application The default operator name is Administrator Different operators have wider or more restricted security rights trom complete control over the system to the ability only to view one section All operator passwords are case sensitive To define operators 1 In the Tree View expand the Users element and select Operators 2 On the toolbar click the F icon The Add Operator window opens Operator Properties Description C Localize guard Location Fights Modify Networks None Configuration
127. ows you to add cameras to the network and to configure each camera s setting For more information see Section 5 8 4 5 4 Timing The Timing tree branch consists of two elements time zones and Holidays 4 5 4 1 Time Zones A time zone defines a weekly time period or set of time periods for example Office Hours or Out of Office Hours Door access rights alarms and input and output behavior can all be set to behave differently within each Time Zone 36 AxTraxNG Software Installation and User Manual Syste m Ove rvi ew SECURITY PROD UCTS For more information see Section 5 1 4 5 4 2 Holidays This element defines annual holiday dates it is possible to set special access behaviors for holiday time For more information see Section 5 2 4 5 5 Groups The Groups tree branch consists of four elements Access groups Access Areas Output Groups and Input Groups 4 5 5 1 Access Groups An Access Group defines when each reader on the site is available for access All site personnel are assigned to appropriate Access Groups For more information see Section 5 10 1 4 5 5 2 Input and Output Groups Input and Output groups define sets of outputs or inputs that should be managed together within a panel For more information see Sections 5 10 1 5 10 2 and 5 10 3 4 5 5 3 Access Areas A facility can be subdivided into several access areas to configure and manage it more effectively For more information see Section
128. port What report do you wish to produce Attendance report Cancel 3 From the first dropdown list select a report type From the second dropdown list select which report you wish to produce 5 Click Next Follow the on screen wizard instructions until the wizard has completed The display area lists the new report AxTraxNG Software Installation and User Manual 121 Administrator Operations 11 Administrator Operations 11 1 Setting the Time and Date You can select panels by network and reset their date and time to the AxTraxNG server s system date and time using the Set Time window To reset the panel time 1 In the Tree View expand the Networks element and select a network 2 On the toolbar click the icon The Set Time window opens 1 Check the panels for time setting Sate Time 2 Set the system time 31 5 10 03 hh mm 3 Click pply to sent the new time C Custom Date Time Description Status DateTime Select All 1 Panel 2 Connected 31 5 11 10 03 57 O 1 Panel 3 Connected 31 5 11 10 03 56 i 3 Select the panels to reset 4 Click Apply The server connects to the panels and sets the time as requested A dialog contirms the operation 11 2 Downloading Failed Data In the event that some data fails to download to the access control panels it is possible to perform a download of the failed operations only You can perform this operation on a single panel on all
129. prefer setting Port value of 4243 rather than 4200 This avoids colliding with port addresses reserved for various equipment installed on the same network 10 Click OK to start the verification process 11 Turn off the MD N32 power or panel power if using the onboard module such as MD IP32 and then turn the power on again This step is necessary when using certain versions of MD N32 or MD IP32 models Skip this step if not applicable 12 If configuration applies to a WAN network disconnect the configured unit trom the local network and reconnect to the WAN network and access control panels network working over the WAN To configure MD N33 in AxTraxNG 1 In the AxTraxNG software add a new network 2 Under network type select Modem General Options Description Network 3 i Enabled Hy Network type 2345 v Modem Network Com Port 1 Speed 9600 Configuration Communication speed is limited to 9600 19200 57600 or 115200 bits per second AxTraxNG Software Installation and User Manual 135 Network Configuration To initialize and contigure the computer modem 1 10 11 136 In the Network window click Configuration The Modem Configuration window opens Modem configuration FES PC modem Remote modem Dialing Remote modem phone number Number of dial attempts Additional dialing string options Use default Dialing schedule Time Zone Disconnect by schedule end Ne
130. puters as needed to help monitor the system ViTrax software Enables video integration if needed HASP key driver AxTraxNG Server only AxTraxNG Watchdog In addition the setup installs the following two prerequisite applications Crystal Reports Basic Runtime for Visual Studio 2008 Microsoft Visual C 2005 SP1 3 1 Choosing an SQL Server The AxTraxNG Server operates using an SQL server 2005 2008 database If there Is already an SQL 2005 2008 server available on your computer network use it to run the AxTraxNG database using your SQL login credentials Alternatively install Microsoft SQL Server Express on the computer that uses the AxTraxNG server Do not install the SQL server when installing additional AxTraxNG clients which connect to the AxTraxNG Server database 3 2 Preparing the AxTraxNG Installation Install the AxTraxNG Access Control software on the computer that connects to the access control panels and manages the database To begin installing the AxTraxNG software 1 Insert the CD into your computer s CD drive 2 Double click the AxTraxNG setup Tile The following verification screen opens 16 AxTraxNG Software Installation and User Manual l n sta ati O n SECURITY PROD CTS Open File Security Warning The publisher could not be verified Are you sure pou want to run this software Name AxTraxWGsetup 1 0227 5 30 04 2013 exe Publisher Unknow
131. rious parameter groups that you wish to download 5 Click OK AxTraxNG Software Installation and User Manual 107 Intrusion Integration 8 5 Editing HLX Settings After you have downloaded various parameter groups to the GUI you can easily change the settings using the Settings options In the Tree View expand the HomeLogiX element and select the HLX In the Table View area select one of the parameter groups On the toolbar click the icon To edit HLX settings 1 panel 2 3 4 A window opens for the selected parameter group For example if Zones was chosen the Zones Settings window opens Zones Settings gt i 6 8 6 H Type Delay Delay Perimeter Interior Interior Interior Interior on On elw niea Interior Interior Interior Interior Interior Interior Interior Interior Interior v v v v v v v v v v v v v v v v v Interior Description ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC ATTIC Chime Type ai birt a No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime No Chime SIVISISISISISISI SSSI TISISICISISISISICIKISI III ISI VOODOO 0 00 00 00 0 0 0 Change the settings as needed Click OK Uploading to the HLX Panel Once you have made your changes to the various parameter group
132. s 0 20 Server run as console application 1 2 Error Log Sending If you are experiencing problems with the server you can use this function to send a report to Rosslare Customer Support for help The Error Log Sending screen contains following fields Table 27 Watchdog gt Error Log Sending Screen Hardware Configuration Select this checkbox if you want to sends Hardware configuration with Error log Operating System Sends OS version with Error log List of Users Sends Users list with Error log List of Installed Programs ae List of installed programs with Error og List of SQL Servers Sends List of SQL Servers with Error log Event Log Messages Sends Windows Event Log with Error log Ping Networks Sends network ping result with Error log Get connection string from server Hi connection string of DB with error og This option is enabled when Ping Network checkbox is selected SQL Server PC address with SQL server installed 150 AxTraxNG Software Installation and User Manual AxTrax NET Watchdog Database Username Password AxTraxNG Old AxTrax radio buttons Sender section Email Company Name Problem Buttons Save Button Send Button SECURIT PRODUCTS DB name Username of DB Password of DB DB of AxTraxNG of Old AxTrax Sender Email Sender Company Sender Name Short description of problem Saves log to local machine Sends the log to Rosslare Customer Support These options are enabl
133. s the changes can then be uploaded back to the HLX panel To upload parameters to the HLX panel 1 2 3 108 In the Tree View expand the HomeLogiX element and select the HLX panel On the toolbar click the icon The Upload to HLX7 window opens AxTraxNG Software Installation and User Manual Intrusion Integration SECURITY PRODUCTS Upload from HLX 1 C Al Account Information L Zones L Enrollment C Security L Communications C Automation C Messages 4 Select the various parameter groups that you wish to upload 5 Click OK 8 7 Live System View The Live System View option allows you to manage system monitoring arming and disarming via the GUI To open the live system view 1 In the Tree View expand the HomeLogiX element and select the HLX panel 2 On the toolbar click the amp icon 3 The Live System View window opens AxTraxNG Software Installation and User Manual 109 Intrusion Integration Live System iew Status Legend Zones 1 20 Zones 21 40 Status Alarm 4 RF Tamper Low Battery B Supervised S Bypass lt No AC C RF Jam uJ On 0 Repeaters T B Panel State Unknown RAF Siren T B Actions Zone Bypass PGM Arming Con FJ on Arm Home Arm Away Ls m Diam 4 Set the system monitoring arming and disarming parameters according to the various available
134. s as desired Click Save 152 AxTraxNG Software Installation and User Manual AxTrax NET Watchdog 1 4 Restart Server If you try to open the AxTraxNG Client but you get an error that the server is not connected you may need to restart the server To restart the server 1 Click the Restart Server topic The Aestart server button appears F AxTraxNG Watchdog Restart Server 2 Click Restart server 3 Enter the administrator password and click OK The server restarts within a few seconds AxTraxNG Software Installation and User Manual 153 Adding Custom Wiegand Formats J Adding Custom Wiegand Formats The Wiegand protocol it the most common protocol between readers and controllers This protocol is actually a collection of bits that represents the number of the user card ID There are many types of Wiegand protocols Protocols differ from one another depending on the following three factors The number of bits sent per card The most common format Is 26 bit but there are many more types such as 30 32 35 and 36 bit The representation of the user number In each card there is a number that defines the user but the representation of this number inside the Wiegand protocol can be changed In addition there is a Facility code in most protocols which is not part of the number but is common to all users in this particular area There are cards with additional codes such as Site code but Ax
135. s tab contains the following fields Table 17 Departments Users gt Department gt User Properties gt Details Tab Field Telephone Mobile Fax Email Address Description Type an office telephone number for the user Type a cell phone number for the user Type a fax number for the user Type an email address for the user Type a postal address for the user Home telephone _ Type a home telephone number for the user Car registration Type the user s license plate number Title Type the user s title e g Mr Employment Date Enter the date that the user joined the firm Notes Details Type any additional information Click to open the user s additional details folder AxTraxNG Software Installation and User Manual 75 Setting Up a Site 5 13 2 4 User Fields Tab The User Fields tab can be used to store any information required by the system operator User fields are defined in the Tools gt Options gt User Fields Default tab see Section 11 5 2 To add a user 1 In the Tree View expand the Departments Users element and select a department for the new user 2 On the toolbar click the F icon The Add User window opens 3 Enter the user details as needed using the tabs described in the above Subsections 4 Click OK The window closes and the added user Is displayed 5 13 3 Adding Visitors AxTraxNG stores contact details for each visitor associated card details and visitor access
136. sdaaudngaceensSeacimsaunmcsdaseaetien 122 11 2 Downloading Failed Data viscid ext tcsdeiinien tie duactieatddeidencteunetiadedocakeat 122 11 3 Testing User COUNEIS serrer nrn er EEE Srii 123 11 4 Maintaining the Database scesccesscave casssasratsewendne uavactactadarratewecce 123 11 5 AxTraxNG Options and Preferences cccceeceecccccceeesseeeeeeeeeeeas 124 11 5 1 OTS TD esar ceasciap ee teat E i E 125 11 5 2 USEF Custom Fields civcavsscsctonssatticane soinsduestiantadisiandsaredinendandanlmtaddussclandadicaeies 125 11 6 Importing Exporting User Data ors siseciwacsnctactecedancnedbvisinentwnddadsbonescnts 126 11 7 AXirax GUI View ODTIOMS ust csecterenscecucsatndsesmnetevaenceadtucensecemedinemcssdine 128 A Firewall Configuration c scsscsscssssseseessessessenseeseeeees 129 B SQL Service Settings nnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn a 133 C Network Configuration cccccscsssssssessesseseeseeseeeeeseees 134 D Restoring Factory Default SettingS ccscssesseeseees 139 E Configuring User Counters csccscsssssesseseesseneeeeeeeees 140 E 1 Resetting Counter on Panel Re enable cccceccccceeeceeeeeeeeeeeeees 140 F Cross Platform Camera Setulp csscsssssssssssssseeseeneens 142 G Enrolling Cards using MD 08 Desktop Reader 145 H SQL Server Installation Troubleshoot scsscsseee 146 I AxTrax NET Watchdog csccscesceseeseseesenseeeesenseneeeensenes 149
137. software and log in to the main window To start AxTraxNG 1 Double click the AxTraxNG Client icon MO on the desktop or select the program from the Rosslare folder in the Start menu If the AxTraxNG server is installed on a different PC the Server connection dialog box appears Server connection IP Address Fort A662 a If the AxTraxNG server is installed on the same PC skip to Step 5 after the Logon AxTraxNG Client Dialog box appears 2 Type the AxTraxNG server s PC IP address in the IP Address text box 3 Select the AxTraxNG server s PC Port from the Port select box Click OK The Server connection dialog box closes and the Logon AxTraxNG Client dialog box appears Logon AxTraxNG Client 0 10 0 y Please check name and enter password Operator name Administrator ka Fassword oOo O O 5 Select an Operator name and enter a Password AxTraxNG Software Installation and User Manual 29 System Overview By default the Administrator operator password is admin 4 Note 6 Click OK The main AxTraxNG window opens 4 2 AxTraxNG Main Window The entire central functionality of the AxTraxNG system Is available from the AxTraxNG Client main window BA TRA gt lt Everts me t The AxTraxNG Client Main window is divided into six adjustable sections Table 1 AxTraxNG Client Main Window Section Description 1 Menu Bar
138. ss Access Granted any user 0 04 Enabled Time Zone C Generate Alarm Always New 5 In the Destination Type dropdown list select Local recording In the Destination dropdown list select a camera momentary recording or pre event recording 7 Click OK 6 5 Viewing Recorded Events In the Camera Properties window you can view live streaming and edit various camera properties The Camera Properties window includes the following Table 19 Network gt Panel gt Cameras gt Camera Properties Window Field Description Description Displays the camera name Enable ViTrax Select this checkbox to enable motion detection in ViTrax Motion Detector Enabling motion detection enables Record Motion features It is possible to get motion detection events from ViTrax and use them to initiate recording by first setting the Motion Detection section on this window and then setting motion detection properties in ViTrax in the Sensitivity Exclusion Format and Source tabs AxTraxNG Software Installation and User Manual 91 ViTrax Video Integration Field Time Lapse Frame rate Live Audio Volume Audio to Camera Microphone Device Properties Options PC Archive Local Archive Snapshot Activation buttons Description This checkbox is automatically enabled due to the camera recording settings Time Lapse refers to the periodic recording of single frames AxTraxNG automatically
139. ss Recorded Mark to checkbox to enable a pop up window for Access Recorded event type alerts Close window Once a pop up is enabled the close window options are Options available Select one of two options e Manually The operator is required to manually close the pop up window e By timer The pop up window closes automatically based on the predefined timer Camera Select the name of the camera that takes snapshots or that Available only with appears when triggered by this reader AC 525 For example the camera named 1 Panel 1 Camera A AC 525 To configure a reader 1 In the Tree View click AC Networks 2 Select a network and expand a panel in the Tree View 3 Select Readers AxTraxNG Software Installation and User Manual 57 Setting Up a Site The available readers are listed in the display area 4 Select a reader in the display area On the toolbar click the FF icon The Reader Properties window opens to the General tab 6 Configure the reader as needed using the tabs described in the above Subsections 7 Click OK 5 7 Configuring the Inputs Each panel has four inputs Using the MD IO84 expansion board adds an additional eight inputs a total of 12 inputs Using the MD D02 or MD D04 expansion board adds four inputs a total of 8 inputs Some inputs are dedicated and have default functionality and some are for general purpose The nout Properties table window displays the settings for each input Input t
140. tered list then appears in the main window 4 5 8 4 Cards This element lists all cards in the system with their statuses and allows the manual or automatic addition of cards to the system For more information see Section 5 10 4 2 In addition the element allows you to create a card template for printing For more information see Chapter 7 4 5 8 5 Operators Operators are people with access to the AxTraxNG software The default operator names are Administrator Engineer and Security Different operators have wider or more restricted security rights trom complete control over the system to the ability only to view one section All Operator passwords are case sensitive For more information see Section 5 17 4 5 9 Status Map The Status Map creates a graphic display of the statuses for every door reader and alarm in the facility on user selected images The system can display multiple nested status maps allowing users to show either the complete access control network or a specific area in detail For more information see Section 5 19 4 5 10 Reports AxTraxNG can produce various reports including usage reports attendance records visitors and roll calls The AxTraxNG Report Wizard allows users to design their own custom reports based on their needs For more information see Chapter 10 38 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 5 Setting Up a Site This
141. that can be linked cameras that have already been linked do not appear in this window 88 AxTraxNG Software Installation and User Manual ViTrax Video Integration SECURITY PRODUCTS Add Cameras from itrax Vilrax Server Description Details ae ahs 127 0 0 1 USB Video Device DirectShow Video Sources d 3 For a camera you wish to link select the Attach to AxTraxNG checkbox 4 Click OK The linked camera now appears in the Table View screen rl You can also click the oa icon in the Events List to view the list of linked cameras Note 5 Inthe Tree View click AC Networks Select a network and expand the panel to which you want to link the camera 7 Select AC Links 8 On the toolbar click the FF icon The Add Link window opens Source Type Destination Type A o Source o Destination Input 1 1 Panel 2 Door REX v None Event Operation Contact Closed None Event Description Contact Closed Enabled Time Zone C Generate Alarm Always 9 Select the Generate Alarm checkbox to activate the Alarm Handler button 10 Click Alarm Handler The A arm Handler window opens AxTraxNG Software Installation and User Manual 89 ViTrax Video Integration Alarm handler PC RQ1 Message Popup Cameras options Alarm Message Camera A Options C Popup Enabled Use highlight alarm event Select Color Sound Select Wave
142. the area Select a time zone during which access should be granted only after both the card and PIN are entered The PIN must be entered within 10 seconds of card entry Note When using a secured time zone Keypad type must be defined Select the checkbox to allow the reader to unlock the door Select the checkbox to record this entry against the user s entry allowance counter See Section 5 13 2 1 Select the data transmission type for the primary reader hardware Select the data transmission type for the secondary reader hardware Note This field is used when 2 different types of cards are used Select the data transmission type for the type of keypad hardware Select the checkbox to allow access to any user assigned to a facility listed in the selected list of facilities The list of facilities is defined in the Options tab Select the checkbox to interface with the AYC W6500 biometric Biometric Reader reader and its PC application BioTrax 5 6 2 Options Tab The Options tab in the Reader window displays Timed antipassback settings for the reader Restricted site access settings AxTraxNG Software Installation and User Manual 23 SESC ERO Setting Up a Site Timed antipassback Automatic antipassback Never v Hard alarm and access denied Soft alarm only Time 1 1 to 255 minutes Facility Codes 0 255 The Options tab in the Reader window contains the following fiel
143. upplements Internet based services and support services for this software unless other terms accompany those items If so those terme apply By using the software you accept these terms Ifyou do not accept Do vou accept all of the terme of the preceding License Agreement If you choose No Install will close To install you must accept this agreement Once these installations finish the AxTraxNG Client installation begins 3 3 Installing AxTraxNG Client Software The installation wizard opens automatically once the prerequisite software is installed If you are upgrading the following screen opens 18 AxTraxNG Software Installation and User Manual Installation SECURITY PRODUCTS AxTraxNG Client 2 This setup will perform an upgrade of AxTraxNG Client Do you want to continue Welcome to the InstallShield Wizard for AxTraxNG Client The InstallShield R Wizard will install AxTraxNG Client on your computer To continue click Next WARNING This program is protected by copyright law and international treaties To install the AxTraxNG Client application 1 Click Yes and or Next to begin the AxTraxNG Client installation process 2 Ifyou are installing an upgrade skip to Step 5 The Destination Folder screen opens i AxTraxNG Client InstallShield Wizard Destination Folder Click Next to install to this folder or click Change to install to a different F ca
144. ver Disconnect on upload complete Settings Initialization string In the Dialing area under Remote modem phone number type the destination telephone number to call Click to change the Number of dial attempts if required For most applications the default dialing string is sufficient The dialing string is displayed in the window Clear the Use default checkbox This allows adding or editing of the dialing string Then type the AT command in the Dialing string window From the Dialing schedule dropdown list select the time zone Choose the disconnecting condition Disconnect by schedule end or Disconnect on upload complete This option is enabled when the selected time zone is different from the default time zone Always and Never In the Settings area the initialization string is displayed in the window For most applications the default initialization string is sufficient Clear the Use default checkbox to allow adding or editing of the dialing string Then type the AT command in the Dialing string window Connect the computer s modem to the PC via the selected COM port and click Apply to initialize the PC modem Click OK to complete the initialization If the computer displays a failure message check the modem connections and repeat the last steps Remote modem initialization is at the PC side When modem initialization fails through telephone line a message appears AxTraxNG Software Installation an
145. w access group appears in the View Tree 4 Select the access group from the View Tree and click the icon AxTraxNG Software Installation and User Manual 63 Setting Up a Site The Access Group Properties window opens Access Group Details Time zone en v Available 1 Panel 2 Reader 1 1 Panel 2 Reader 2 1 Panel 3 Reader 1 1 Panel 3 Reader 2 2 Panel 2 Reader 1 2 Panel 2 Reader 2 Selected J _ J 5 From the 7ime zone dropdown select a time Select and move the desired readers from Available to Selected using the arrows 7 Click OK The window closes and the new access group appears in the Display Area 5 10 2 Adding Input Groups Input groups are a collection of inputs from one or more panels that can be used in panel links to perform advanced operations To create an input group 1 In the Tree View expand the Groups element 2 Select Inputs Groups 3 On the toolbar click the F icon The nout Group window opens 64 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS Description Maea E By Network 1 Select all 4 Inthe Description field enter a name for the input group 5 Expand a network to see its panels Input Group Destin Sy Network 1 Select All 14Panel 2 EJZ 1 Panel 2 Door 1 REX JA 1 Panel 2 Door 1 Monitor A 1 Panel 2 Door 2 REX CJA 1 Panel 2 Door 2 Monitor a 1 Panel 3 4 1 Pan
146. ware Installation and User Manual AxTrax NET Watchdog SECOURI PROD UCTES AxTrax NET Watchdog The AxTrax NET Watchdog is a program that monitors the AxTrax server Double click the L icon in the Window system tray to open the program B AxTraxNG Watchdog l 0 x Common Info Server run as console application Error Log Sending DB Connection Server is running without errors Restart Server Downloads 0 Networks OK 4 Panels Connected 12 The main window contains the following four topics Common Info Shows general system information Error Log Sending Sends error log to Rosslare Customer Support DB Connection Changes DB connection string Note Administrator password is required Restart Server Restarts the AxTraxNG server Note Administrator password is required Once the main window opens you can click on any of the three main topics to open that topic s screen AxTraxNG Software Installation and User Manual 149 AxTrax NET Watchdog 1 1 Common Info This screen shows general system information server status downloads counter number of networks number of panels and networks and panels Status In addition if you import an earlier database from VeriTrax AS 225 AxTrax AS 525 the progress of the import is displayed in Common Info 2101 x Common Info Error Log Sending DB Connection Import earlier database versions from Yeritrax AS 225 A4xTrax AS 525 ae ia Import access event
147. window see Section 9 1 Send the current display area view to the printer Add a new element of the selected type Edit the selected element Delete the selected item Configure custom reader type General Network Icons Name Add to Status Map Download Failed Data Manually Network Icons Name Set Time Find Panels Manual Modem Camera Click icon to Add available panels and panel components to the Status Map see Section 4 5 9 Download the entire panels failed database see Section 11 2 Click icon to Set the time on the selected access control panel see Section 11 1 Find and update panels within the network see Section 5 4 2 Open the Modem Status window to allow the operator to connect or disconnect the modem and change the connection password see Appendix C View a list of connected cameras and assign the cameras to panels see Section 6 2 AxTraxNG Software Installation and User Manual 33 System Overview 4 4 4 Icon d t C 4 4 5 Icon E EE 4 4 6 Icon 34 Panel Icons Name Manual Reader Update Firmware Control Output Manually Control Input Manually Control Siren Manually Click icon to Change the operation mode of the readers on the selected panel see Section 9 2 Send a firmware update to the selected access control panel see Section 9 6 Change the settings for the outputs on the selected panel see Sectio
148. with Extended door open rights Set the duration for which the door can be held open without raising an alarm event Select the checkbox to use this timer for the Server application the Pop up and Snapshot section opens Note If this feature is enabled then the Activity start delay Section 5 7 feature for that door must be set to 0 Set the duration after which when the door is forced open an event occurs Select the checkbox to use this timer for the Server application the Pop up and Snapshot section opens Note If this feature is enabled then the Activity start delay Section 5 7 feature for that door must be set to 0 To edit the door properties 1 In the Tree View click AC Networks 2 Select a network and expand a panel in the Tree View 3 Select Doors The available doors are listed in the display area 4 Select a door in the display area AxTraxNG Software Installation and User Manual 53 Setting Up a Site 5 On the toolbar click the F icon The Door Properties window opens 6 Configure the door as required 7 Click OK 5 6 Configuring the Readers A panel can be connected to two four or eight readers when the MD DO2 or MD 04 extension boards are connected The Reader Properties window has three tabs Genera tab Sets the reader general operation settings Options tab Sets access options for the reader Access event tab Sets options for window pop ups per event 5 6 1 General
149. work type as TCP IP If you want to work with Remote in the TCP IP Network window select Remote WAN and add the WAN IP Address of the PC Note 5 Click Configuration The TCP IP Configuration window opens Tcp Ip Configuration Configuration Version Configuration C 5 Gateway Type Serial Speed 00 50 C2 78 90 74 MD IP32 On Board Y 9600 v 00 50 C2 78 93 F1 Network 1 video Configured Local IP Local Port 192 168 20 16 6666 Subnet 255 255 255 0 Gateway 192 168 20 250 Search Options AIMD N32 Direct MAC address 00 00 00 00 00 00 O Direct P Address 134 AxTraxNG Software Installation and User Manual Network Configuration SECURITY PRODUCTS The upper left window lists all TCP IP converters attached on the local network identified by their MAC address and indicates if they are available to be assigned to a new panel network or are already assigned 6 From the MD N32 list the MD N32 s MAC address should be labeled on the TCP IP converter select the appropriate MAC address 7 In Gateway Type select the type of TCP IP converter MD N32 MD IP32 On board or any other valid option Skip this selection if it is already valid 8 Type the Local IP address and Subnet for the computer s network 9 Enter the Local Port number and select the Speed of your connection It is recommended to select a higher value port number 4001 or higher Note that the selected should not end with zeros
150. xtussantncensenandds tamsades a a aea A Eia sents 65 5104 Detining Card Card GrOUDS wos steidsnenusaionnedsdetesnelnceeaudianlenncuiteighaubedebatelberts 66 5 11 Adding User ana Cards esascs eungap a paag 67 5 11 1 Setting Card AUTOMATION wi cwoiiansccsssdindcderans cronedunatoniausaconedencraundenecoubasarnisiawes 69 el ASC CSI ac E E E E tne arte dawmentunestade teas 70 5 13 Adding Departments Users and VISItOIS ccccccceeeccceeeeeceeeeeeeeeaees 70 5 13 1 Adding Department cccccccccssccceeeeseeceeeeeeeceeeeeeeeceeseeeeeeeseeeeeeeaneeeeeeegs 70 Bee FIFI AT SEU ice acto vsaus arazatueated iamearcbndannseaien AEEA E EASIER aE AEAEE 70 DSS AGNO ISIC ONS esoe E tock aieeeoesraundodiatasences aa tucnatnces 76 5 14 Adding Access Areas rs cssteccectasenensatalennsecnwieruecenalcosunmentotandlaicestocmnebencnganaee 77 5 15 Adding Global Antipassback Rules sssnnnsssinnuuessrinnesnrrnrsrrrrrrennn 78 SMO E e A e E A E E 79 5 16 1 Viewing and Editing Car Parking Counters ccccccccceeececeeseeeeeeeaeeeeeenans 81 5 17 Ad imng Operator caiisescinascort Secnalsivk watelaioneeiinedtes ae siea aaa 82 5 18 Creating Elevator SONU horsicacamoncantenctcrmisaarseduaacenoiantseenbeoarstiacer 83 5 19 Creating Status Maps caccseccscsvscncessatsinseestecasenchwnsunstnderedacicesteseseasnnes 83 6 ViTrax Video Integration c ccssssceseesenseeeeeenseneeeeneees 86 6 1 Connecting to Vilrax Sever i ccccnsanncne eanec
151. you can choose the protocol you wish to view and click the icon The Custom Reader Settings window opens 158 AxTraxNG Software Installation and User Manual Adding Custom Wiegand Formats SECURITY PRODUCTS Custom Reader Settings Set as Default E1111111111110000000000000 00000000000001111111111110 O00000000DDDDDDDDDDDDDDDDO OFFFFFFFFOOOo0000000000000 p The protocol representation is for viewing only and cannot be edited te Note For help in creating a new protocol please refer to Customer Support AxTraxNG Software Installation and User Manual 159 OF Asia Pacific Middle East Africa Rosslare Enterprises Ltd Kowloon Bay Hong Kong Tel 852 2795 5630 Fax 852 2795 1508 support apac rosslaresecurity com United States and Canada Rosslare Security Products Inc Southlake TX USA Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 support na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com AxTraxNG Latin America Rosslare Latin America Buenos Aires Argentina support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electronics India Pvt Ltd Tel Fax 91 20 40147830 Mobile
152. ype is programmed individually regardless of whether it is a dedicated input or for general purpose use The nout Properties table contains the following fields Table 12 Network gt Panel gt Inputs gt Input Properties Field Description Location A display field showing the input name Description Type a name for the input Type Select the type of input to be monitored e Normally Open Close An input either in an open or closed state e Normally Open Close 1 Resistor An input in an open closed or trouble state This option is only available for supervised inputs e Normally Open Close 2 Resistors An input in an open closed or trouble state with additional checks for short circuit and open circuit tampering This option is only available for supervised inputs For more information refer to the Access Control Panel s hardware manual Activity start Set the delay time before this input becomes active Note that on delay normally open input the delay starts once the input contact is closed On normally closed input the delay starts once the input contact opens To contigure an input 1 In the Tree View click AC Networks 2 Select a network and expand a panel in the Tree View 3 Select Inputs The available inputs are listed in the display area 58 AxTraxNG Software Installation and User Manual Setting Up a Site SECURITY PRODUCTS 4 Select an input from the display area 5 On the toolbar click the F icon

Download Pdf Manuals

image

Related Search

Related Contents

Acronis Backup & Recovery 10 Advanced Workstation  こちら  D5503 - Fnac  Echanges fructueux sur le patrimoine départemental  Brother FAX-920 Fax Machine User Manual    

Copyright © All rights reserved.
Failed to retrieve file