Home

USER`S MANUAL

image

Contents

1. Preferences a C PerfectLum Registration Activation Workstation Settings 1 Enter Serial Number Calibration Settings 2 Choose Activation Type QA Settings Automatic Online Activation Manual Activation x Remote and Network Settings i i mem Retype mal t PerfectLum Display Settings H9FS803320 Registration Activation OLORIN MC190D 1 Enter Serial Number seri ONI ial serial number 2 Choose Activation Type 9 Automatic Online Activation Manual Activation Email Address email Retype Email email l PerfectLum Suite Cancel License activated successfully Return to License List e cuBvx For manual activation follow the link and fill out the form that you will find on the website Enter the generated workstation ID that you see below into the corresponding field of the form When you submit the form an activation code will be sent to your e mail Enter this code into the field below and click Activate Registration Activation 1 Enter Serial Number 2 Choose Activation Type Automatic Online Activation 9 Manual Activation 2 1 From any computer go to this link http www gubyx com index php register 2 2 Enter the bellow shown ID on the website Generated workstation ID 2384 C106 2 3 An activation code will be sent to your email Copy that code and paste it here Activation code Return to License List Cancel e cuBvx Wh
2. Licenses Functionality PerfectLum Suite PerfectLum Suite Function Calibrate Display Hardware calibration and DDC CI USB Serial z usage Adjust White Level Verify calibration Verify White Level Generate Display ICC Profile P Adjust Gamut Perform Acceptance Test ES Perform Constancy Tests Schedule QA Tasks Edit Settings Edit Calibration Settings Edit QA Settings Measure Color Display Test Pattern Remote Control z T Note Quick access to preferences is Ctrl P for Windows or Command P for Mac OS X e cuBvx 5 3 License Activation To activate the Calibration and QA license click the License option in the main window and select Registration Activation noon License und Licensing When the Registration Activation window opens enter the serial number you 3 Losses Capability of connecting to a remote management web application Qubyx Remote for managing a display network easily O neeme License for acceptance tests under different regulations and managing the quality assurance QA obtained when you purchased a license and choose an activation type C Calibration License License for different kinds of calibrations and verification of such calibrations Add License Cancel e cuBvx For automatic online activation just enter and repeat your e mail address and click the Activate button
3. Remote and Network Settings Activate Remote Control for the workstation and connect it to the PerfectLum Remote Control server 2 5 1 Enable Remote Enter the IP address or the server address like https remote qubyx com into the field Server Address Enter the username and the password of the PerfectLum Remote user account and click the Enable Remote Management button When connection is established a dialog will pop up asking you to select the workgroup for this workstation Select the workgroup and click Save then all the data schedules history and preferences will be immediately synchronized with the remote server Note Remote Admin account needs to be created first on PerfectLum Remote In addition to this you have to create a workgroup a facility and user accounts on Remote Server in advance 2 5 2 Remote Database Synchronization Select the time interval within which you want to synchronize the databases between the client and the server 2 5 3 Your Proxy Server Check the Use Proxy box if you use a proxy server to access the internet This action is required in order to access PerfectLum Remote Management server if you do not use it on the intranet and for activating software license automatically via internet Note If the Use Proxy box is checked the license activation will be performed using the given settings e cuBvx III LICENSE AND LICENSING 3 1 Remote License Remote license is included for
4. energy save mode for a set time period In the energy save mode the backlight of the display is switched off to save energy and to extend backlight lifetime 2 3 Calibration Settings 2 3 1 Calibration Type DICOM Gamma e cuBvx CIE L Calibrates to the Color Space Lab of the CIE Commission Internationale d Eclairage Defines the image format parameters and values for HDTV specifies the opto electronic transfer characteristics at the source BT 709 Specifies the reference electro optical transfer function that the displays used in HDTV programme SURE production should follow in order to facilitate consistent picture presentation 2 3 2 Color Temperature Check the Adjust Color Temperature box to calibrate the color of the display and to adjust the display to reach target color temperature You can enter the target color temperature in 3 different ways CIE Standard light source color Standard lights between D50 and P93 D65 is the mostly used value and represents daylight presets Color Temperature Enter a value for color temperature Color temperature is less precise and doesn t represent a standard like CIE standards Advanced settings x and y value Enter the x and y coordinates of the CIE xyY color space The values are generally used to match any other device or film 2 3 3 Gamut Check the Adjust Gamut box to include a Gamut calibration into the calibration process Select the predefined color
5. into a different folder cick the Browse button and select another folder You can choose not to install PerfectLum 3 8 by clicking Cancel to exit the Wise Installation Wizard Destination Folder C Program Files x86 Qubyx PerfectLum 3 Browse Installation Wizard lt Back Next Cancel If you don t want to install PerfectLum Suite into the default directory browse your computer and choose another one Windows will present a driver message for a few times during PerfectLum Suite installation This is normal behavior as drivers to support measurement devices are loaded Please click the Install this driver software anyway button when prompted e cuBvx 6 Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information vw See details 1 4 3 Measurement Device Installation Now that you have the software installed it is time to install the measurement device Plug the device into an unused USB port and refer to the following depending on which OS you have installed the software Vista and Windows 7 IM il Pro AX Vista and Windows 7 will automatically install your device driver Wa
6. of QA tests will be used for this display 4 9 Display Technology Select if the display is a Flat screen LCD or a CRT screen Depending on your selection different thresholds in QA regulations will be applied 4 10 Screen Size The software will read the diagonal size of the display automatically 4 11 Resolution h v The software will read the horizontal and vertical resolution of the display automatically The resolution will be documented in QA reports 4 12 Backlight Stabilization Select if the display has integrated backlight stabilization that maintains the white level of the display constant over time If the display has backlight stabilization the intervals for QA test will be longer e cuBvx 4 13 Installation Date Enter the date when the display was installed V REGISTRATION 5 1 Free and Additional Features PerfectLum has free and additional features Free features are available as soon as you install PerfectLum Additional features can be unlocked by buying the display calibration and QA license aol ru Calibration Conformance Display Calibration White Level Conformance White Level Calibration Display Test Pattern OA Acceptance Tests Measure Color OA Constancy Tests Sync with remote Create ICC Profiles 3D Gamut Viewer History and Reporting Task Scheduling There are two possibilities to access the licensing part over Preferences or License section from the main window e cuBvx 5 2
7. settings DB Host localhost DE User Name root DB Password 123123 DB Name perfectlum DB Table Prefix va r_ Super Admin settings Full name Super Admin Login Password E mail e cuBvx e cuBvx Workgroups create at least one workgroup e g CT Radiology etc Users create an admin user 2 Now you can connect from client application Perfectlum Suite to Qubyx Remote New open preferences and go to Remote and Network Settings enter Qubyx Remote IP as Server Address enter the admin user you have created and the password for this admin user click on the Enable Remote Management button That s it Now your workstation is connected to Qubyx Remote and will synchronize its data at certain intervals which are set in the same dialog 7 4 Acronyms DICOM Digital Imaging and Communications in Medicine GSDF Gray Scale Display Function CIE Commission Internationale d Eclairage BT Broadcasting service television NEMA National Electrical Manufacturers Association AAPM American Association of Physicists in Medicine DIN Deutsches Institut f r Normung IEC International Electrotechnical Commission NY PDM the New York state Primary Diagnostic Monitor PDM Quality Assurance Program JESRA Japanese Engineering Standards of Radiological Apparatus LUT Look Up Table DDL Digital Driving Levels JND Just Noticeable Difference OSD On Screen Display e cuBvx 7 5 QUBYX SOFTWARE
8. space or enter your own by clicking the Advanced button 2 3 4 White Level Check the Set White Level box to adjust the white level luminance of the display to a certain value Enter the target value in candelas e cuBvx into the field 2 3 5 Black Level Check the Set Black Level box to adjust the black level luminance of the display to a certain value Enter the target value in candelas into the field 2 3 6 ICC ICM Profile If you want to include an ICC Profile creation into the calibration process check the Create ICC ICM Profile box and select the necessary chromatic adaptation 2 4 QA Settings All information related to the Quality Assurance Regulations is entered in this section 2 4 1 Regulation Select the Regulation you want to use and the Application Category Regulation Category Application Mammography Mammography A Diagnostic B Reviewing Dental Dental Projection Radiology Projection Radiology AAPM TG18 JESRA X 0093 IEC 62563 1 NY PDM Click the Show Tests button to see QA tests that are part of this regulation Fluoroscopy Computer Tomography Dental Mammography Operation Room Primary Secondary Category 1 Category 2 Diagnostic Reviewing Monochrome Reviewing Color Mammography No Mammography e cuBvx Fluoroscopy Computer Tomography Dental Mammography Operation Room Diagnostic Reviewing Diagnostic Reviewing Diagnostic Review
9. FREE You can connect and manage your displays with QUBYX PerfectLum Remote server The following features are also free Calibration Conformance White Level Conformance Display Test Pattern Measure color 3 2 PerfectLum Suite License PerfectLum Suite license is required to perform Calibration and White Level Calibration QA Acceptance and Constancy tests for AAPM TG18 JESRA X DIN 6868 57 DIN 6868 157 IEC 62563 1 and NY PDM regulations In order to activate the license click the Add License button enter the license code and your email address into the selected fields and click Activate The license will be activated if your workstation is connected to the internet If it is not connected go to http qubyx com index php register from any other machine and enter the license code and the ID number from the workstation visible in the license activation window You will receive an unlock code Enter this code into the activation window to activate and unlock the software IV DISPLAY SETTINGS The displays connected to the workstation are visible in separate tabs Select a display to adjust the settings for that specific display 4 1 Ignore Display Check the Exclude Display from Testing Calibration box if you do not want to perform any Quality Assurance tests or calibration on a specified display 4 2 Calibration Upload Calibration upload will select the location where LUT Look Up Table will be saved and the exact communicati
10. LICENSE AGREEMENT IMPORTANT READ CAREFULLY This License Agreement Agreement is a legal contract between You a user You and QUBYX LTD NICE France OUBYX for the QUBYX software identified above which encompasses all material and software accompanying this Agreement including computer software associated printed material readme file online help and any other accompanying information and documentation collectively Software By clicking the acceptance button installing or otherwise using the Software You are consenting to be bound by the terms of this Agreement If You do not agree to all of the terms of this Agreement QUBYX is not willing to license the Software to You If You do not agree to be bound by the terms of this Agreement click the button that indicates that You do not accept its terms do not install copy or otherwise use the Software and contact OUBYX in France 33 1 809 638 20 for instructions on how to return the unused Software 1 Software License a Grant of License QUBYX hereby licenses to the extent described below the use of the software but does not sell the Software to You You acknowledge that You do not acquire any rights of ownership or title in the Software You own the media and the dongle if any on which the Software resides and is copy protected respectively but QUBYX retains all right title and interest in and to the Software which is the subject of copyright trade secret tradema
11. MD K7 Minimum RAM 512MB Minimum free space on hard disk 150 MB e Mac OS X 10 6 Snow Leopard 32 bit and 64 bit 10 7 Lion 10 8 Mountain Lion 10 9 Mavericks 10 10 Yosemite Intel hardware is reguired Processor Intel only No PowerPC support Minimum RAM 512MB Minimum free space on hard disk 150 MB Oooooo e cuBvx e cuBvx 1 2 2 PerfectLum Remote server is supported on the following operating systems am e Windows hosts T Windows XP all service packs 32 bit Windows Server 2003 32 bit Windows Vista 32 bit and 64 bit Windows Server 2008 32 bit and 64 bit Windows Server 2012 Windows 7 32 bit and 64 bit Windows 8 32 bit and 64 bit Windows 8 1 32 bit and 64 bit oooooooo e Mac OS X hosts O 10 6 Snow Leopard Intel 32 bit and Intel 64 bit O 10 7 Lion O 10 8 Mountain Lion O 10 9 Mavericks O 10 10 Yosemite A e_ Linux hosts 32 bit and 64 bit Among others this includes O Ubuntu 6 06 Dapper Drake 6 10 Edgy Eft 7 04 Feisty Fawn 7 10 Gutsy Gibbon 8 04 Hardy Heron 8 10 Intrepid Ibex 9 04 Jaunty Jackalope 9 10 Karmic Koala 10 04 Lucid Lynx 10 10 Maverick Meerkat 11 04 Natty Narwhal 11 10 Oneiric Ocelot 12 04 Precise Pangolin 12 10 Quantal Quetzal 13 04 Raring Ringtail 13 10 Saucy Salamander 14 04 Trusty Tahr Debian GNU Linux 3 1 sarge 4 0 etch 5 0 lenny 6 0 squeeze 7 0 CWhee
12. OR ADVICE GIVEN BY QUBYX OR QUBYX S AUTHORIZED REPRESENTATIVE OR ANY REPRESENTATION MADE BY QUBYX OR ITS AUTHORIZED REPRESENTATIVE SHALL CREATE ANY WARRANTY 9 Limitation of Liability UNDER NO CIRCUMSTANCES SHALL QUBYX BE LIABLE FOR ANY LOST REVENUE OR PROFITS OR ANY INCIDENTAL INDIRECT SPECIAL PUNITIVE OR CONSEQUENTIAL DAMAGES THAT RESULT FROM THE USE OR INABILITY TO USE THE SOFTWARE EVEN IF QUBYX OR ITS AUTHORIZED REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE OR SUCH DAMAGES WERE CAUSED BY QUBYX S NEGLIGENCE IN NO EVENT SHALL QUBYX S TOTAL LIABILITY TO YOU FOR ALL DAMAGES LOSSES AND CAUSES OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE OR OTHERWISE EXCEED THE AMOUNT PAID BY YOU FOR THE SOFTWARE 10 General a The material laws of France shall govern the interpretation and enforcement of this Agreement If You are in North America the material laws of the State of New York shall govern the interpretation and enforcement of this Agreement 5 If any term or provision of this Agreement or application thereof to any person or circumstances shall to any extent be invalid or unenforceable the remainder of this Agreement or the application of such term or provision to persons or circumstances other than that which is held to be unenforceable or invalid shall not be affected thereby and each such term and provision shall be valid and be enforced to the full extent permitted by law C This Agreem
13. PerfectLum3 perfectlum exe remote http remote perfectlum com testuser testpassword our group e cuBvx d logs p3log log Notes lt PATH to Log gt is an optional parameter in all commands lt GROUP_NAME gt is the name of a workgroup you want to connect your machine to Case insensitive but sensitive to the whitespaces 7 3 PerfectLum Remote System Administrator Guide System Requirements Virtual Machine VM is provided as an OVA package So you need virtualization software which supports OVF Open Virtualization Format and vmdk disk images Oracle VirtualBox is the preferred choice for running this VM However you can also use VMware products About 550 Mb of free space is needed for an OVA package and minimum 2 GB needed for VM production use 1 5 GB base system and 500 Mb for database and backups Note that database and backup images are constantly growing so you may consider having more free Space in advance 1 Installing and configuring VM You should use the Import Appliance option from the File menu of Oracle VirtualBox Manager in order to install VM All required settings are predefined However you may tune some settings such aS amount of memory to better fit your requirements We recommend to select the correct network card in virtual machine settings network tab before the first start After successful installation you may safely start VM You may log into console when the login prompt ap
14. Perform this task 8 every day pn working days only th day 2 30 D every 2 ak w Startdate 2014 8 21 E 1 5 3 History Tab SyncMaster H9FS803320 c gt Be l co OLORIN MC190D OLM12060006 Calibration and QA Scheduler Main Info Task Type Device Performed Date Time DIN 6868 157 Acceptance Test OLORIN MC190D OLM12060006 2014 08 21 12 28 50 O mensem x EN meesuxm x Er U A Ob 0x O OI Y _ _OcLh LIC NNNNCT ams MM Oa IA I o em KY YO A i a O IAI O Ia eT Y ON ec i O Calhentinn DM h A CTC MTC nEI I 110412 ENIODWVO 7737C amp ng MIA no 1011 24 27 Show Display Consistency Display Report Perform Selected Task Again e cuBvx In the History Tab you can view tasks that were performed in the past Simply double click on a task to see the detailed report Select a task from the list and click Perform Selected Task Again to restart the task e cuBvx The search field enables you to filter task types displays dates and results The Show Display Consistency function indicates white and black levels of a selected display over time on a graph The graph is shown when enough data is collected e g 2 or more tasks were performed on a display Note that the data are shown only for connected displays Display Report shows the option where you can select a time interval and a display for which you want to see a rep
15. Person Responsible 2 5 Remote and Network Settings 2 5 1 Enable Remote 2 5 2 Remote Database Synchronization 2 5 3 Proxy Server III LICENSE AND LICENSING 3 1 Remote License 3 2 PerfectLum Suite License IV DISPLAY SETTINGS 4 1 Ignore Display 4 2 LUT Upload VI VII 4 3 Used Sensor 4 4 Display Model 4 5 Display Serial Number 4 6 Display Manufacturer 4 7 Inventory number 4 8 Type of Display 4 9 Display Technology 4 10 Screen Size 4 11 Resolution h v 4 12 Backlight Stabilization 4 13 Installation Date REGISTRATION 5 1 Free and Additional Features 5 2 Licenses Functionality 5 3 License Activation PERFECTLUM SUITE MENU ITEMS 6 1 Software Update 6 2 About us 6 3 Measure Color 6 4 Display Test Pattern 6 5 3 D Gamut Viewer 6 6 Notification 6 7 Report OTHER 7 1 Matching Multiple Displays 7 2 Mass Installation of PerfectLum Suite version 3 e cuBvx e cuBvx 7 3 PerfectLum Remote System Administrator Guide 4 Acronyms 7 5 Qubyx Software License Agreement I GETTING STARTED 1 1 Introduction When it comes to medical imaging the ability to see the whole image is important With a standard workstation configuration using an uncalibrated display the user runs the risk of missing fine details Missing fine details can represent a health risk to the patient which may lead to a misdiagnosis or an expensive lawsuit The problem is not t
16. SQL Accounts MySQL Administrator account Login root Password bemy349R00t PerfectLum Database account Login perfectlum Password elj390g J Id0289 Use perfectlum MySQL database while installing Remote Management Firewall Settings New incoming connections are accepted for the following TCP ports 20 21 22 80 443 11001 e cuBvx e cuBvx New incoming connections are accepted for the following UDP ports 68 All other new incoming connections which do not satisfy the stated rules are rejected All new incoming connections from localhost are accepted All outgoing connections are accepted Webmin Webmin is a web based interface for system administration for Unix Using any modern web browser you can setup user accounts Apache DNS file sharing and much more Webmin is listening 11001 TCP port Point your browser to http VM IP ADDRESS 11001 and log in using one of default accounts to use it PerfectLum Remote site configuration Enter the IP address static IP or DHCP in your browser A setup screen where you can set the name password and email of Super Admin will appear Then click Install If the installation was successful a congratulation screen will show up Before you can connect workstations to Qubyx Remote some preparations are necessary 1 In Qubyx Remote go to the Setup tab and then to Facilities create a new facility e g NYU Medical Center C PerfectLum Database
17. Your Device provided that Your Device continues to be owned by You or in Your possession at such time that a profile is made available to such third party or e cuBvx ii to create LUTs and profiles by using reference characteristic data which are publicly and without consideration provided by professional or trade associations like standardization institutes to be used for their intended purpose b No Distribution of generic LUTs and profiles This Agreement does not grant You the right to distribute or embed created LUTs and profiles also not under Your private label into any software devices or consumables like Computer Displays Digital cameras Printers Projectors paper that You manufacture market or distribute to third parties If You wish to create LUTs and profiles for this purpose You will need a separate license for each device With regard to generic LUTs and profiles created by non profit organizations like the ECI QUBYX is however prepared to permit to embed such LUTs and profiles into any software devices or consumables to be distributed commercially by an agreement on a case by case basis For information on a separate license You may contact support qubyx com 3 Copyrights Trademarks and Patents The marks PerfectLum PressProof DisplayAProof QUBYX ChromaView as well as QUBYX s logo are registered trademarks of QUBYX or its affiliated companies The technology in this product is covered by European patents w
18. art of the Software ii No other Use Except as expressly permitted in Section 1 a above You may not disclose distribute modify make or have made any copies of the Software in whole or in part nor sell rent lease license or lend the Software without prior written authorization of QUBYX iii Multiple installation Single Use at the time The Software may be used by You on one single personal computer or workstation at the time Specifically You may install the Software on more than one computer at Your premises or at Your home at a time however the use of the Software must always be connected with the use of the dongle provided by QUBYX You are not permitted to circumvent the protection given by the dongle Furthermore it is not allowed to use the Software or to network the Software to multiple computers or terminals without first obtaining an expanded license from QUBYX to cover such additional users and computers QUBYX may replace the dongle by any other means of protection without previous announcement 2 Use of LUT Look Up Table and profiles a The Software is licensed for use only as follows i to create LUTs and profiles on a specific input or output device that You own or otherwise possess and for which they were created Your Device You may make these LUTs and profiles available to third parties only under circumstances in which the third party will be optimizing images that have been created on or will be output on
19. ca Minolta CA210 Totoku CCL256i2 Totoku CCL258i2 1 3 3 Displays with internal LUT L L D L L D L L DL L DL G L D L O D L L NEC MultiSync LCD 1980 NEC MultiSync LCD 2180 IIYAMA PLH2130 2 IIYAMA PLH2130 3 LumiMED MMO2 LumiMED MMO3 LumiMED MMO5 LumiMED MMO3A LumiMED MMO5A Olorin VL211D Olorin VL200D Olorin VC210D Olorin VC19012 Olorin MC20012 Olorin VC21012 Olorin MC210D Olorin VC190D Olorin MC190D Olorin MC200D Olorin VC210D Olorin MC191D Olorin MC221D Rein VIEWMEDIC EV C119 Rein VIEWMEDIC RV C219 Rein VIEWMEDIC RV C221 DELL U3011 DELL U3014 DELL U2413 DELL UP2414Q DELL U2713H DELL U2414 DELL UP3214Q Sony LMD DM20 Sony LMD DM30 Sony LMD DM50 Sony LMD DM20C Sony LMD DM30C Sony LMD DM50C il Totoku CCL254i2 il Totoku CCL256i2 Totoku CCL258i2 LL Totoku CCL352i2 Totoku CCL354i2 Totoku CCL356i2 Totoku CCL358i2 LLL LL DLL C O C O C C L L e cuBvx e cuBvx 1 4 Installation Procedure Overview 1 4 1 Pre installation conditions In order to install PerfectLum Suite client you must have Administrator privileges or Administrator s password if required when installing to the user profile Before installing PerfectLum Suite software in your system Power on the workstation with all display s attached that you intend to use Check if the screen settings are correctly configured XP Go to Settings Control panel and double click on the display icon Select the Sett
20. ctLum Remote Server it can still run all QA tasks on the workstation PerfectLum Remote Server All PerfectLum Suite clients can be connected to PerfectLum Remote Server No special license is required QA managers can connect to PerfectLum Remote Server via internet intranet connection and take full control over the performance of connected workstations from any location at any given time EN m mu Cloud mu dB Qubyx Servers Intranet EN e cuBvx 1 4 2 Installation Windows Vista 7 8 Double click on the installer Welcome to the PerfectLum 3 8 Installation Wizard Itis strongly recommended that you exit all Windows programs before running this setup program Click Cancel to quit the setup program then dose any programs you have running Click Mext to continue the installation WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion af it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law e cuBvx Follow the instructions presented in the installer and click on the QUBYX software license agreement after reading it carefully isl Perfectl um 3 8 Setup Destination Folder Select a folder where the application will be installed The Wise Installation Wizard will install the files for PerfectLum 3 8 in the following folder To install
21. d NY PDM The function automatically generates schedules for the corresponding conformance tests You can view the threshold values for each regulation by clicking the Show Thresholds button in QA Settings If you have already performed the acceptance test s you can import it into PerfectLum with the help of the Import Acceptance Values Feature see section 2 4 2 Calibration Conformance The function checks and validates the quality of the calibration and of the display ICC profile according to the preferences you have selected as Calibration targets White Level Conformance verifies the display s luminance level All listed above functions except Create ICC Profile can also be performed in the demo version which will be available during 15 days e cuBvx 1 5 2 Scheduler Tab gt PerfectLum Suite 3 PerfectLum Suite Settings Tools License C PerfectLum Calibration and QA History s Main Info Lo SyncMaster c H9FS803320 Task Type Scheduled Date Time Frequency Last Execution DIN 6868 157 QA Constancy Test visual OLORIN MC190D OLM12060006 2014 08 21 Daily Never DIN 6868 157 QA Constancy Test visual OLORIN MC190D OLM12060006 2015 02 21 2014 08 21 DIN 6868 157 QA Constancy Test measu OLORIN MC190D OLM12060006 2015 02 21 2014 08 21 LI RE Per elected Tas Add New Task Edit Task Delete Task In the Scheduler Tab you can see automatically scheduled QA Constancy tasks depending on
22. e that the Wizard will not pop up if you have opened the preferences before The acceptance test consists of two parts a measurement part and a set of visual tests The exact tests are determined by the selected regulation For measurement tests an on screen or a handheld measurement device can be used Please refer to the list of supported measurement devices for detailed information After the acceptance test was performed associated Consistency QA Tasks are automatically scheduled II PREFERENCES 2 1 Application Settings 2 1 1 Language Set the language of the application Supported languages English German Japanese Chinese Korean French 2 1 2 Software Update Check the Update Software Automatically box if you want the software to notify you about new software updates 2 1 3 Password Protection When you check the Protect Settings by Password box two fields will appear Enter a password in the first field and repeat it in the second field IMPORTANT Make sure you note down the password in a secured location for future use since you can not recover it from the system e cuBvx Once the preferences are protected by a password they can be changed only when the correct password is entered If the wrong password is entered the settings are visible but can not be changed 2 1 4 Export Import Common Settings Settings of the application can be exported into one file as backup or as golden settings The same s
23. e cuBvx T PerfeciLum USER S MANUAL QUBYX LTD www qubyx com http perfectlum com Support qubyx com info qubyx com e cuBvx TABLE OF CONTENTS I GETTING STARTED 1 1 Introduction 1 2 Minimum system requirements 1 2 1 PerfectLum client is supported on the following operating systems 1 2 2 PerfectLum Remote server is supported on the following operating systems 1 2 3 Your web browser should be one of the following 1 3 Hardware requirements 1 3 1 Displays and Graphic boards 1 3 2 Measurement devices 1 3 3 Displays with Internal LUT 1 4 Installation Procedure Overview 1 4 1 Pre installation conditions 1 4 2 Installation 1 4 3 Measurement Device Installation 1 5 The Main Window 1 5 1 Calibration and QA Tab 1 5 2 Scheduler Tab 1 5 3 History Tab 1 6 Do my first calibration 1 7 Do my first QA Acceptance test II PREFERENCES 2 1 Application Settings 2 1 1 Language 2 1 2 Software Update 2 1 3 Password Protection 2 1 4 Export Import Common Settings e cuBvx 2 1 5 Backup Recover 2 2 Workstation Settings 2 2 1 Workstation name 2 2 2 Ambient light 2 2 3 Task Delay 2 2 4 Sleep Mode 2 3 Calibration Settings 2 3 1 Calibration Type 2 3 2 Color Temperature 2 3 3 Gamut 2 3 4 White Level 2 3 5 Black Level 2 3 6 ICC ICM Profile 2 4 QA Settings 2 4 1 Regulation 2 4 2 Import Acceptance Values 2 4 3 Workstation Location 2 4 4
24. eal sys Ta C S WINDOWSSSpstem32 D rers lt Back Cancel When all drivers have been loaded and configured the wizard will prompt you to click on the Finish button e cuBvx Found New Hardware Wizard Gompleting the Found New Hardware Wizard The wizard has finished installing the software for O Sequel Imaging USB Calibration Device Click Finish to close the wizard lt Back Cancel Windows will notify you when the measurement device is ready to use by momentarily displaying the Found New Hardware message balloon in the lower right corner of the screen e cuBvx Mac OS Double click on the installer Proceed by double clicking on the box 6 9 PerfectLum Suite C Perfecttum PerfectLum Suite Installer _v3 8_b318 pkg Double click the icon to begin installation e cuBvx e00 we Install PerfectLum Suite l Welcome to the PerfectLum 5uite Installer A Introduction License You will be guided through the steps necessary to install this software e Desti e ins e a Perfectlum Go ack Comime Follow the instructions presented in the installer and click on the QUBYX software license agreement after reading it carefully e cuBvx e00 Install PerfectLum Suite l Standard Install on MacOS 10 9 Introduction P MEM This will take 99 8 MB of space on your computer Click Install to perform a standard installation of this software
25. en you finish the license activation all licenses in the Preferences License and Licensing section will be marked as active License and Licensing 4 Remote License Capability of connecting to a remote management web application Qubyx Remote for managing a display network easily 4 anticense License for acceptance tests under different regulations and managing the quality assurance QA Ce oaio ino Display Settings License for different kinds of calibrations and verification of such calibrations Cancel VI PERFECTLUM SUITE MENU ITEMS 6 1 Software Update Preferences Ctrl P Software Update About Us Quit Ctrl Q QUY X PL Main Info e cuBvx This function checks the server for a new PerfectLum Suite version You will get a link to download a new version if there exists one 6 2 About Us The window where you can see our contact information license agreement license information and version installed Tools PerfectLum Suite Settings Tools License Measure Color Ctrl M Display Test Pattern Ctrl T 3D Gamut Viewer Ctrl G QUBYX PC Main Info e cuBvx Tools are accessible in PerfectLum Suite from the Main Window gt Tools Note Tools are included for free use 6 3 Measure Color This function will open two windows In the first window you can start measurement Mix color and gray levels will be displayed in the second window where measurements are actually performed F
26. ent constitutes the entire understanding of the parties with respect to the Software and supersedes all prior and contemporaneous agreements understandings representations warranties promises and other communications of any kind whether e cuBvx written or oral between the parties with respect to the Software No alteration modification variation or waiver of this Agreement or any of the provisions hereof shall be effective unless executed by both parties in writing
27. ent devices unfortunately still have considerable deviations when measuring color So it is recommended to use the same device on all displays 3 Identify the weakest display If you want all displays to have the same white level you need to know which of them has the lowest one and measure it This white level will become the target value for all displays It is important to have the same white level on e cuBvx displays that are connected to one workstation and installed side by side 4 Set your target values for white level color temperature and luminance response in PerfectLum Preferences 5 Perform a display calibration with those same settings on each of your displays 7 2 Read Me mass installation of PerfectLum Suite version 3 Create your master settings file Before performing a mass auto installation you need to prepare your master settings file To do this just make ONE usual installation and set all needed configurations in preferences Important Do not forget eventual proxy settings if they are used in your network Then go again to Preferences Application and click Export The software will create the needed file for auto configuration The file extension is qbxs save the file in your preferred location Export Import To import settings please push the Import button and choose the path Common Settings To export current settings please push the Export button and choose the directory Dateiname I
28. ettings can be imported into the application from other machines to work with the same settings and to save time during installations To export the settings click on the Export button and browse the directory to select the folder where you want to save the settings To import the settings click on the Import button browse for the qbxs settings file and click OK Please note that the Display Settings and the Remote and Network Settings will not be recovered Display settings and serial numbers can differ from each other and the different remote and network settings can be set on different workstations 2 1 5 Backup Recover This function will back up the entire database with all history data settings and schedules Click on the Backup button and browse the directory where you want to save the database Click Recover and browse the qbx database backup file to recover the database Please note that the Display Settings and the Remote and Network Settings will not be recovered Display settings and serial numbers can differ from each other and the different remote and network settings can be set on different workstations Check the Activate auto backup box to have the software run an automatic backup every day week or month Select the directory where you want the database to be saved Note If the path you ve chosen for auto backup is changed renamed or deleted folder the path line will become selected with a red frame c
29. for all users of this computer All users of this camputer will be able to use this software Perfectlum ue mai Click Install to begin the installation e cuBvx 1 5 The Main Window Preliminary Conditions Before using the software make sure the following conditions are observed ambient light should be constant ambient light should be as low as possible no direct light should reach the display The tasks included in the Main Window On the left you can notice a list of displays linked to the PC PerfectLum Suite provides visual feedback to help identify your display in a multiple head situation Double clicking on the selected display icon will identify the selected screen PerfectLum Suite Main window has 3 Tabs Calibration and QA Tab Here you can initiate calibrations and QA tasks Scheduler Tab Here you can manage your scheduled tasks History Tab Here you can view history data In the center of each tab there are buttons or lists of tasks to access all of the functionalities of the software e cuBvx 1 5 1 Calibration and QA Tab PerfectLum Suite 3 PerfectLum Suite Settings Tools License C P erfectLum Calibration and QA Scheduler History Main Info LJ SyncMaster Calibration c H9FS803320 _ m Calibration re Starts the display calibration L emer Calibration parameters can be defined in the preferences White Level Calibration Starts t
30. he image or the practitioner s eye it is the ability of the display to represent all information accurately PerfectLum Suite is a software solution which enables the user to modify display output to meet DICOM part 14 GSDF and other key industry standards After calibration your workstation will allow you to see the finest details of every image displayed With PerfectLum Suite medical display calibration software installed on all of your computers you are assured that no matter which image you are looking at it will be the same on every display PerfectLum Suite is not only a DICOM calibration tool but also a medical monitor QA application that verifies the display s conformance to medical standards AAPM TG18 DIN 6868 57 DIN 6868 157 JESRA X 0093 IEC 62563 1 the New York state Primary Diagnostic Monitor PDM Quality Assurance Program and performs acceptance and conformance tests for these standards This document provides details on installation and use of the PerfectLum Suite application About PerfectLum Suite e cuBvx PerfectLum Suite is a medical monitor quality assurance suite based on the medical standards NEMA DICOM part 14 GSDF AAPM TG18 DIN 6868 57 DIN 6868 157 JESRA X 0093 IEC 62563 1 and NY PDM The medical monitor QA tool performs calibration acceptance test conformance test and maintains consistency to all medical workstations The use of this software enables healthcare professionals to maintain international s
31. he white level calibration Parameters for the white level can be defined in the preferences Create ICC Profile Create an ICC profile for the selected display s Quality Assurance Acceptance Test Starts a new acceptance test D pi The regulation can be chosen in the preferences White Level Conformance The white level verification checks if the white level is within a certain range Calibration Conformance Checks and validates the auality of the calibration and of the display ICC profile Uniformity Conformance The uniformity check measures the luminance deviation across the screen The deviation should be limited to the preset range Calibration this function allows you to calibrate your display The software will adjust your monitor based on your selected preferences First select the display you want to calibrate from the left menu and then click the Calibration button e cuBvx IMPORTANT Calibration should always be started on a warmed up display Warm up time is specified by the display manufacturer minimum 30 minutes White Level Calibration adjusts the white level of your display to the target luminance in candelas Create ICC Profile creates a LUT based ICC v4 profile of the display with the selected settings of the chromatic adaptation Acceptance Test this task allows you to perform an acceptance test according to one of the following regulations AAPM TG18 JESRA X DIN 6868 57 DIN 6868 157 IEC 62563 1 an
32. hoose a correct path for auto backup and save preferences 2 2 Workstation Settings 2 2 1 Workstation Name e cuBvx The workstation name is read automatically from the system It can be overwritten to be personalized The workstation name can be changed and is used on the remote management server to identify your workstation among the others 2 2 2 Ambient light Ambient Light is the reflection of ambient light on the switched off display panel Enter a value for ambient light in candelas if you know it or click the Measure Ambient Light button to measure the reflection During this process the software will switch off the backlight of the panel You must place the sensor 15 cm away from the display facing the switched off panel The software will measure the reflection of an ambient light on the display panel During the measurement process don t move the mouse and don t hit any keys as it will switch the display back on Once the measurement is finished the display will be automatically switched back on 2 2 3 Task Delay Check the Use Scheduler to remind me when Tasks are due box to program the application to automatically remind you when a task is due This function can also schedule start tasks automatically Set the time between 5 and 60 minutes for the display to warm up after the system boot before starting any scheduled tasks 2 2 4 Sleep Mode Check the Put display to Energy Saving Mode box to put the display into an
33. ing Reviewing Mammography Diagnostic Click the Show Thresholds button to see the thresholds that will be applied during QA tests for this regulation and category e cuBvx 2 4 2 Import Acceptance Values Easily import all your previously performed QA tests into PerfectLum with the Import Acceptance Values feature In order to use this function please go to Preferences gt QA Settings select the desired regulation and click the Import Acceptance Values button Then select a display date of the test and a name of a tester who performed the test If the constancy tests have been passed please set the dates they were performed and check the appropriate boxes After you have entered the values measured in the imported test s click OK and wait until the confirmation message appears C coo TS UC NEUES 9 C PerfeciLtum Workstation Settings Used Regulation Regulation DIN 6868 157 v Calibration Settings QA Settings Room Class Mammography Remote and Network Settings and Li 8 Workstation Location Facility Qubyx Limited Department IT Display Settings Room 4 Responsible Person MarcLeppla H2300S IPH23SY110001 Address 80 rue Marechal Joffre City Nie U3011 Email leppla amp qubyx com Phone Number 33 180 963 820 Display IPH23005 IPH235Y 110001 Date of Test 29 04 2015 x Tester Mame Marc Leppla Last Constancy Test Execu
34. ings tab to view screen resolution and color settings Vista Go to Settings Control panel and click on Adjust screen resolution under the Appearance and Personalisation Icon Windows 7 and 8 Go to Control panel gt Display gt Adjust resolution Mac OS X System Preferences Displays and choose resolution radio box Best for display Ensure that the screen resolution is set to the native resolution of the display with color quality of 32 bit True color or higher Ensure that the correct graphics card display driver is installed Repeat these checks for each display attached to your system Your system is now ready to start the installation process IMPORTANT Before starting the installation process please make sure that the USB measurement device is NOT connected The measurement device will be added later after PerfectLum Suite is successfully installed PerfectLum Suite can be operated as a client only or as a client server combination Complete installation consists of several components e cuBvx PerfectLum Suite Client PerfectLum Suite Client is the client application that runs on each of the workstations It provides a number of actions that can be performed locally on the workstations including calibrating the displays viewing test patterns or performing full QA Quality Assurance and acceptance tests QA tests available only in PerfectLum Suite Even when PerfectLum Suite Client is not connected to Perfe
35. ion 8 2 3 Color impression and uniformity 8 2 4 8 2 5 Visibility of line structures in the test pattern TG 18 4 PH10 8 2 9 Visibility of line structures in the test pattern TG 184 PH50 8 2 9 Visibility of line structures in the test pattern TG 18 4 PH893 8 2 9 Visibility af line structures in the test pattern TG184 PV 10 8 2 9 Visibility of line structures in the test pattern TG 18 4 PV 50 8 2 9 Visibility of line structures in the test pattern TG18 LPV89 8 2 9 Clinical Reference Images 8 2 8 Pixel Errors 8 2 5 Pixel Size 8 4 8 5 Display Resolution 8 4 8 5 Luminance Uniformity 8 3 6 MultiDisplay Uniformity 8 3 7 Maximum minimum veiling luminance and maximum luminance ratio 8 3 1 8 3 2 8 3 3 8 3 5 Luminance response curve 8 3 8 Illumination 8 3 4 e cuBvx If you want to exclude the specific QA or Constancy tests data from the display report you can click the right button on them in the History tab and select the Disable option 2 4 3 Workstation Location The workstation location contains the information about the workstation used to perform the tasks e g Display Calibration QA Please enter the information regarding your facility department and room Note this information will be displayed in reports e cuBvx 2 4 4 Person Responsible The person responsible is the person who should be notified if something is wrong with the workstation Please enter the information into the corresponding fields 2 5
36. irst select the RGB color patch with sliders or by entering a number for RGB values Then place the measurement device on the patch and start measuring You can perform two measurements the software will compare them and will display color difference in Delta E with or without L Luminance Note Quick access to this tool is Ctrl M Command M on MAC OS 6 4 Display Test Pattern Select the display where you want the test pattern to be displayed and select the test pattern you want to display Click View and Check For displaying a test image that is not in the list but is available on the system select User Image click View and Check navigate to your image file and open it Click on the test pattern or press Escape button on your keyboard to close it Note Quick access to this tool is Ctrl T Command T on MAC OS 6 5 3 D Gamut Viewer This function graphically displays the 3D gamuts of different profiles using the selected color spaces and rendering intents It is possible to calculate the percentage of Gamut intersection of two profiles 6 6 Notification After a task is created PerfectLum Suite Task Notification will pop up at the scheduled time provided that the warm up time has expired see Use Scheduler to remind me when Tasks are due Click the Perform Scheduled Tasks button to carry out a scheduled task or e cuBvx Remind Me In button to remind the user about the task later You can also choose the
37. is Agreement will automatically and immediately terminate without notice from QUBYX or the requirement of any other action by QUBYX Upon termination by QUBYX You must destroy or return to QUBYX all copies of the Software in Your control 6 Improvements You agree that QUBYX may on a non exclusive basis use for any purpose in any media now known or hereafter devised all suggestions improvements and any other information ideas concepts know how works of authorship and inventions including corrections to problems with the Software whether written or oral collectively Improvements developed by You during the term of this Agreement You will promptly notify QUBYX of all such Improvements without any duty of accounting or other compensation by QUBYX 7 Government Licensee If You are acquiring the Software on behalf of any unit or agency of the United States Government the following provisions apply The Government acknowledges QUBYX s representations that a the Software was developed at private expense contains information that is confidential and proprietary to QUBYX is a trade secret and is copyrighted and b the Software is Restricted Computer Software as that term is defined in Clause 52 227 19 of the Federal Acquisition Regulations FAR and is Commercial Computer Software as that term is defined in the Department of Defense Federal Acquisition Regulation Supplement DFARS The Government agrees that if the Software is
38. it until you receive ame Device driver software installed successfully the Device driver software installed successfully message and jump ahead to the end of this section Windows XP The Found new Hardware Wizard will start Click the Yes this time only radio button followed by Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation LD or an the Windows Update Web site ith your permission Head aur privacy policy Can Windows connect to windows Update ta search For software 2 Yes this time only C Yes now and every time connect a device C3 No not this time Click Next ta continue Check the Install the Software Automatically Recommended radio button and click Next e cuBvx e cuBvx Found Hew Hardware Wizard Welcome to the Found Mew Hardware Wizard This wizard helps you install software for Sequel Imagina USE Calibration Device 9 If your hardware came with an installation CD EA o floppy disk insert it now What do vau want the wizard to do Install fram a list or specific location Advanced Click Next ta continue The software is installed automatically e cuBvx Found New Hardware Wizard Please wait while the wizard installs the software O Sequel Imaging USE Calibration Device JU s
39. ith additional U S and international patents pending The Software including without limitation any images and text incorporated therein as well as the ICC profiles and LUTs created by You are the subject to international copyright protection This Agreement grants You no other rights licenses or interests of any kind in or to such copyright trademarks and patents other than granted herein You agree that You will assert no other rights licenses or interests other than those granted herein or otherwise challenge QUBYX or QUBYX s affiliated Companies exclusive ownership of such copyrights trademarks and patents 4 Duty to Inform You agree to make reasonable efforts to notify and inform everyone having access to the Software or the computer on which it is installed of all applicable restrictions limiting use of the Software as well as Your other duties and obligations under this Agreement You agree to provide notice to QUBYX immediately after learning of or having reason to suspect a breach of any of the restrictions set forth in this Agreement 5 Termination e cuBvx This Agreement is effective until terminated You may terminate this Agreement at any time by returning to QUBYX any disks CDs and any associated dongles as well as associated documentation or other copies of the Software under Your control together with written notice of Your intent to terminate this Agreement If You fail to comply with any provision of this Agreement th
40. ld run the update exim4 conf script to generate new configuration files and then restart Exim Console nano etc exim4 update exim4 conf conf Modify configuration files according to your needs nano etc exim4 passwd client e cuBvx Write credentials here if your SMTP server requires authentication i update exim4 conf X etc init d exim4 restart Webmin There is no possibility to do this in Webmin 5 Managing backups VM is doing automatic database backups every night Backup starts right after the midnight Backups older than 7 days from the current date are removed automatically Backups are stored at home perfectlum backups in a separate disk image So you can even attach a physical partition or hard drive if you need more space for backups You may use perfectlum restore script to restore database backup for particular date Be careful because perfectlum restore overwrites your current database To restore database backup just run perfectlum restore with full path to backup the file you want to restore Example home perfectlum bin perfectlum restore home perfectlum backups 2011 01 01 perfectlum mysgl backup Don t forget to restart MySQL when restore is finished Simply run the following command etc init d mysal restart Default Settings Default System Accounts System Administrator account Login root Password vb903lejfMPk1 Default unprivileged account Login perfectlum Password plumadmin2912 My
41. mport Settings 2011 08 18 Dateityp Settings files qbxs Installation On every workstation you will need to 1 Copy the PerfectLum Suite installer msi file and the master settings file qbxs file 2 In console run installation in silent mode you MUST have administrative rights e cuBvx msiexec i PATH to installer PerfectLum Installer msi quiet or if you need specific installation path msiexec i PerfectLum Installer v3 0 436 msi gn INSTALLDIR D Apps Qubyx PerfectLum3 Warning the installation will not be completely silent import of PerfectLum2 database will appear for a few seconds Also the user might be asked to apply drivers installation run auto configuration PATH perfectlum exe configure PATH to Settings lt PATH to Log gt Examples C Program Files Qubyx PerfectLum3 perfectlum exe configure default qbxs C Program Files x86 Qubyx PerfectLum3 perfectlum exe configure default qbxs d MogsMo3log log D Apps Qubyx PerfectLum3 perfectlum exe configure d tmp default gqbxs d logs p3log log run auto registration PATH perfectlum exe registration SERIAL MAIL lt PATH to Log gt Example C Program Files Qubyx PerfectLum3 perfectlum exe registration O12XERT2ASDF admin hospital co uk d MogsMo3log log run auto remote enabling PATH perfectlum exe remote SERVER LOGIN PASSWORD GROUP NAME lt PATH to Log gt Example C Program Files Qubyx
42. on channel that will be used to perform the action e cuBvx Note Calibration upload is detected automatically for each display Calibration Upload Look Up Table is saved in Used communication channel Graphics card Graphics card Graphics card DDC CI Display DDC CI i2c channel Serial Display Serial RS232 USB Display USB 4 3 Used Sensor Check the Use Internal Sensor If Possible box if your display has an internal Front Sensor and you want to use that sensor during calibrations Note The sensor is detected automatically for each display If this option is missing that means your display has no Front Sensor available 4 4 Display Model The software will read the model name of the display from its EDID You can change the model name The model name will be visible in calibration and OA reports 4 5 Display Serial Number The software will read the serial number of the display from its EDID You can change the serial number The serial number will be visible in calibration and OA reports 4 6 Display Manufacturer e cuBvx The software will read the name of the display manufacturer from its EDID You can change the name The manufacturer s name will be visible in calibration and QA reports 4 7 Inventory Number You can set an inventory number for the display 4 8 Type of Display Select the type of the display Color or Gray Depending on your choice a different calibration algorithm and a different set
43. ort of all QA tasks performed 1 6 Do my first calibration First select the display you want to calibrate from the menu on the left After that click the Calibration button A Wizard will pop up and will guide you in order to customize the calibration process Please note that the Wizard will not pop up if you have opened the preferences before IMPORTANT Calibration should always be started on a warmed up display Warm up time is specified by the display manufacturer minimum 30 minutes Select the calibration type by choosing between DICOM Gamma CIE L BT 709 and BT 1886 If you want to calibrate the color of the display check Adjust Color Temperature box select the predefined target value or enter your own value by choosing a custom option If you want to adjust the white level check Set White Level box and enter the target white level luminance in candelas After you customized the calibration settings place the sensor on the display and start the calibration process Make sure no ambient light reaches the sensor After calibration is finished a report will pop up on the screen with the calibration results 1 7 Do my first QA Acceptance test e cuBvx When you perform the first acceptance test a Wizard will pop up The Wizard will prompt you to select the regulation and the display category In addition you have to fill in some information about the location of your workstation and the responsible person Please not
44. pears You need to do this in order to check or set up an IP address for VM It takes IP address via DHCP by default but you may want to set a static one 2 TCP IP Settings In order to find VMs current IP address you need to complete following steps e cuBvx 1 Log in as root find passwords in Default Settings document 2 Run ifconfig command and find inet addr for ethO interface in its output Now when you know the IP address of VM you may use it to log in via SSH or Webmin Note that root user is not allowed to log in via SSH so you should log in as perfectlum and then use su command with a root password In order to set a static IP address or change other network configuration settings you should modify etc network interfaces file You can find a full description of interfaces file in Network Configuration article from Debian http wiki debian org NetworkConfigurationz Setting up an Ethernet Interface The alternative way recommended by us is to change system and network settings is Webmin check Default Settings document for Webmin URL You may change boot time network settings by selecting ethO interface at Network Interfaces section of Networking Network Configuration menu Both console way and Webmin way are described for next tasks 3 Configuring firewall VM comes up with small set of predefined rules which are stored at etc iptables rules file and executed at boot time In o
45. rder to modify these rules you should edit firewall initialization script home perfectlum bin perfectlum firewall and then execute it However you may edit etc iptables rules directly or via Webmin but perfectlum firewall script is the recommended way to update firewall rules Console nano home perfectlum bin perfectlum firewall Modify firewall rules and save changes i home perfectlum bin perfectlum firewall e cuBvx Webmin Use Linux Firewall option of Networking menu 4 Mail delivery settings You may want to provide an SMTP server address if you want to receive email notifications from PerfectLum Remote Management The only way to do this is updating the Exim configuration Exim is the MTA Mail Transport Agent software which is responsible for mail delivery Open etc exim4 update exim4 conf conf file in a text editor and set dc smarthost directive value to your SMTP server IP address or hostname If your SMTP server uses a non default port you may define it using two colons Example dc smarthost smtp googlemail com 587 If your SMTP server requires authentication you should define credentials in the etc exim4 passwd client file To do this just open etc exim4 passwd client in a text editor and add a new line with your credentials using the following format smtp_server login password Example smtp googlemail com perfectlum example com examplepassword When all changes are done you shou
46. rk and patent rights among other intellectual property and proprietary rights Proprietary Rights b Restricted use QUBYX hereby grants You under all its Proprietary Rights the personal non exclusive right to install and use the Software for its intended purpose in connection with ICC profiles and LUTs Look Up Tables in particular the creation thereof on a single personal computer or workstation and to make one copy of the Software in machine readable form for backup purposes only You must reproduce the copyright notices and any other proprietary legends that were on the original copy of the Software on any such copy QUBYX grants no rights or license of any kind for the Software to You other than those expressly granted above C Additional Specified Restrictions e cuBvx To avoid any doubt the limited license to use the Software granted above places the following limitations and restrictions on Your use of the Software i Reverse Engineering and Decompilation You understand and acknowledge that the codes structures methods and other elements comprising the software are confidential to and trade secrets of QUBYX Accordingly You may not disassemble decompile reverse engineer or otherwise attempt to create or derive source codes for the computer program comprising the Software or reduce such programs of any of their component structures algorithms or other elements to a human perceivable form You may not modify or translate any p
47. supplied to the Department of Defense DoD the Software is classified as Commercial Computer Software and the Government is acquiring only limited rights on the Software as that term is defined in Clause 252 227 7013 a 13 of the DFARS If the Software is supplied to any unit or agency of the United States Government other than DoD the Government agrees that the Software is classified as Restricted Computer Software and the Government s rights on the Software will be as defined in Clause 52 227 19 c 2 of the FAR 8 No Warranties e cuBvx THE SOFTWARE IS PROVIDED AS IS WITHOUT ANY WARRANTY OF ANY KIND QUBYX EXPRESSLY DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ANY WARRANTIES ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE AND ANY WARRANTIES OF NON INFRINGEMENT OF ANY THIRD PARTY S PATENT S TRADE SECRET S TRADEMARK S COPYRIGHT S OR OTHER INTELLECTUAL PROPERTY RIGHTS QUBYX DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILL MEET YOUR REQUIREMENTS THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE THAT DEFECTS IN THE SOFTWARE WILL OR CAN BE CORRECTED FURTHERMORE QUBYX DOES NOT WARRANT OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE OF THE SOFTWARE IN TERMS OF THEIR CORRECTNESS ACCURACY RELIABILITY OR OTHERWISE NO ORAL OR WRITTEN INFORMATION
48. tandards of quality in terms of their displays performance PerfectLum Suite Features Calibration of all displays to DICOM part 14 GSDF CIE L BT 709 and BT 1886 standard Update of video card LUT or display LUT for displays that comply with the DDC CI standard Calibration of multi head display systems White level and black level calibration Version 4 ICC profile generation Calibration to a certain color temperature and XY coordinates Verification of conformance to the major regulations AAPM TG18 DIN 6868 57 DIN 6868 157 JESRA X 0093 IEC 62563 1 and the New York state Primary Diagnostic Monitor PDM Quality Assurance Program Automated QA performing acceptance and conformance tests Scheduling conformance test automatically and reminders to perform tests Remote quality control Convenient and user friendly calibration and QA reports Color measurement capability Diversified auto backup History log for comparing and checking results of calibrations Briggs SMPTE AAPM test patterns to visually check calibration results Wide OS compatibility including Windows 8 1 and Mac OSX 10 9 4 Many brands of photometer support License supports all users on the installed workstation 1 2 Minimum system reguirements 1 2 1 PerfectLum client is supported on the following operating systems e Windows O XP 32 bit and 64 bit O Vista 32 bit and 64 bit O Win 7 32 bit and 64 bit O Win 8 32 bit and 64 bit Processor Pentium or A
49. the regulation you have selected It is possible to postpone the scheduled tasks add edit and delete locally created tasks Constancy test schedules that were created automatically by PerfectLum Suite software can not be deleted Also schedules that were created from the system admin panel on the remote server can be edited and deleted only by the system admin In order to create a new task click the Add New Task button and select the following options type of task Calibration Create ICC Profile Calibration Conformance White Level Calibration White Level Conformance Display Test Pattern the display you want to perform the task on schedule type Start up Once Daily Weekly Monthly Quarterly Semiannually Annually and the scheduled date and time You can also disable tasks in this case you will not be notified about them by the task notificator Just check the Disable Task box To edit a task select the task click the Edit Task button or double click on the task To delete a task select the task and click on the Delete Task button 1 To launch a new task instantly select the task and click on Perform Selected Task Now In the search field you can filter task types displays dates and freguency a ony e cuBvx i PerfectLum Suite Add Task Task Calibration Display OLORIN MC190D Schedule Type Daily Specify the time and date to launch the task otart time 12 31
50. time interval of getting a reminder in the combo box placed near Closing this window means Remind Me In value that is set in the combo box Note For displays that have Front Sensors measurement tasks that require no manual interruption Display Calibration Display Conformance White Level Calibration White Level Conformance and Create ICC Profile will be started automatically and report will not be shown for the next task to start successfully 6 7 Report After each measurement and QA task you will get a report where you can check your result with more details and graphs and a summary result OK or Failed Reports can also be exported as a PDF file or printed Use these two icons File View dan AJ VII OTHER 7 1 Matching Multiple Displays To achieve identical image reproduction on two or more displays connected to one workstation side by side or several displays connected to different workstations you will need to adjust such characteristics of the displays as color temperature white level and luminance response to the same level To match image reproduction on two or more displays follow this procedure 1 Make sure all displays are set to the same values over the display OSD Especially important are the color pre settings brightness and the contrast settings Doing a factory reset on all displays can be helpful to make sure all of them start from a similar level 2 Use only one measurement device Measurem
51. tion Overall Image Quality 8 2 2 a b c 1 e g Color impression and uniformity 8 2 4 8 2 5 MultiDisplay Uniformity 8 3 7 Maximum minimum veiling luminance and maximum luminance ratio 8 3 1 8 3 2 8 3 3 8 3 5 Luminance response curve 8 3 8 Ilumination 8 3 4 Values Maximum Luminance Ratio Le Ua Um Ambient Luminance Las Maximum Luminance La Minimum Luminance L z Recommended Performance Uniformity measurement in the center of the screen dark Uniformity measurement in the center of the screen light Cancel Daily Semiannually Semiannually Semiannually Semiannually Semiannually 29 04 2015 29 04 2015 29 04 2015 25 04 2015 25 04 2015 29 04 2015 7 q e cuBvx C PerfectLum Suite Operation is completed In order to view a display report you need to complete the following steps 1 2 3 4 Open the History tab in the main window of PerfectLum Click the Display Report button Select the display for which you want to get a report Set the time interval and click OK Display IPH23005 IPH235Y 110001 From date 2015 03 30 s To date 2015 04 29 s Cancel I e cuBvx Now you have a report with clear pass fail indication of test results Note Acceptance Test Overall Image Quality 8 2 2 a b c 1 e g Overall Image Quality 8 2 2 c 2 Overall Image Quality 8 2 2 d Image Geometry 8 2 7 Grayscale resolut
52. zy Oracle Enterprise Linux 4 and 5 Oracle Linux 6 Redhat Enterprise Linux 4 5 and 6 Fedora Core 4 to 20 Gentoo Linux SUSE Linux 9 10 and 11 openSUSE 10 3 11 0 11 1 11 2 11 3 11 4 12 1 12 2 12 3 13 1 Mandriva 2007 1 2008 0 2009 1 2010 0 and 2010 1 OOOOOOO e cuBvx 1 2 3 Your web browser should be one of the following e Mozilla Firefox version 3 5 or higher e Safari version 4 or higher e Google Chrome version 3 or higher e Internet Explorer 8 or higher 1 3 Hardware requirements 1 3 1 Displays and Graphic boards All LCD CRT Displays and Projectors All currently commercially available graphic boards e cuBvx 1 3 2 Measurement devices Display Front Sensor Spectral photometer Spot Luminance meter LumiMED MMO3A X Rite Eye One display X Rite Eye One Pro IBA dosimetry Wellhoefer LX Plus LumiMED MMO5A X Rite Eye One display 2 X Rite Eye One Monitor IBA dosimetry Wellhoefer LX Can Olorin VC19012 X Rite Eye One display Pro PhotoResearch PR 670 Pehamed CD mon Olorin MC20012 X Rite Monaco OPTIX XR IBA dosimetry Wellhoefer LX Chroma Pehamed CD LUX Olorin VC21012 X Rite DTP 94 JETI specbos 1001 Pehamed CD Lux plus Sony LMD DM20 X Rite Seguel Gamma 3 JETI specbos 2001 Sony LMD DM30 X Rite Seguel Chroma 4 JETI specbos 2101 Sony LMD DM50 X Rite Seguel Chroma 5 JETI specbos 4001 Sony LMD DM20C Datacolor Spyder3 Sony LMD DM30C Datacolor Spyder4 Sony LMD DM50C Konica Minolta CS200 Totoku CCL254i2 Koni

Download Pdf Manuals

image

Related Search

Related Contents

Scorpio 1400 (LCD) User Manual  Hospital Respiratory Care Catalogue  日本語版 取扱説明書  Side-Channel Monitoring of Contactless Java Cards  Salut à tous - Over-blog    CYCLE D`ORIENTATiON DE L`ENSEIGNEMENT SECONDAIRE Il  消費生活用製品等による事故等に関する情報提供及び業界における体制  Xerox WorkCentre 6505 User's Manual  Anthro Elevate II  

Copyright © All rights reserved.
Failed to retrieve file