User Manual - Automation Products Group, Inc.

image

Contents

1. 4 00 6 05 101 6mm 153 7mm 2 40 N FN 61 0mm V x M p NS Y 2 NPT 2 30 58 4mm 5 50 lt 2 00 139 7mm 50 8mm LOE 3136 4 00 6 05 gt 101 6mm lt 153 7mm 2 40 Po X 61 0mm J Y T Z lt 3 NPT 3 86 r 98 0mm Y 3 00 5 50 762mm lt 139 7mm APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Specifications Performance Operating Range Beam Pattern Transducer Frequency Response Time Communications Digital Output Inputs Electrical Operational Supply Voltage at sensor Current Draw Power Rating Accuracy Accuracy Resolution Environmental Operating Temperature Internal Temperature Compensation Enclosure Protection Materials of Construction Transducer Housing Upper Housing Transducer Type Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 0 6 15 0 ft 7 in 180 in 178mm 4572mm 6126 1 0 25 0 ft 12 in 300 in 305mm 7620mm 2126 1 5 ft 40 ft 18 in 480 in 458mm 12192mm 3136 9 off axis 43 kHz 3136 69 kHz 2126 6126 Progr
2. Figure 2 1 Mounting Instructions Mounting your LOE is easy if you follow a few simple steps Never over tighten the sensor Always screw in your sensor by hand to avoid cross threading Thread failure can be a problem if you damage threads by over tightening them or by crossing threads IMPORTANT Do not over tighten The sensor should be threaded in only hand tight NOTE Do not mount the sensor where the beam will intersect objects such as fill streams pipes ladder rungs wall seams or corrugated tank walls Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Software Setup Initial setup of the LOE and individual Modbus sensors is done via an embedded web server The embedded server can be accessed by using either the serial number or local IP address of the LOE and a web browser Internet Explorer Chrome Firefox etc NOTE Port 6700 must be open on your local network for the LOE to connect Accessing LOE Embedded Web Server via Serial Number The easier way to access the embedded web server is to type loe xxx into a web browser on a computer connected to the same local network as the LOE xxx represents the numeric portion of the LOE s serial number See Figures 2 2 and 2 3 Figure 2 2 http loe 1340 Q http loe 1340 Google Search Figure 2 3 NOTE If your web browser performs a web search for loe xxx istead of accessing th
3. Figure 2 9 Figure 2 10 NOTE See the Security Setting Menu Page 37 to change this user name and pass word Assigning Modbus Senor Numbers Click on RS 485 Network Settings to bring up the RS485 Settings page See Figure 2 11 See section RS 485 Network Settings for a full descrition of each parameter in this menu Page 38 EH 2400 Baud Checked or UnChecked LJ 2400 Baud 9600 Baud Checked or UnChecked 9600 Baud Numb of Sensors On Line 0 to 10 0 1 Sensor Number to View 1to10 New Sensor Number 0 No Change or 1 to 10 0 Delay Between Call in Times 1 to 60 Seconds 5 Figure 2 11 12 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Change Numb of Sensors On Line to reflect the total number of Modbus sensors you will be connecting to your LOE Click Change to send the new value to the LOE With Sensor Number to View set to 1 for the latest sensor added to the Modbus network set New Sensor Number to the highest available number Click Change to send the new value to the LOE Repeat this process for each Modbus sensor as it is added to the network NOTE If you control the power to each Modbus sensor seperately powering up a new sensor after assigning a Modbus address to the previous sensor will allow you to assign an address to the new sensor without leaving the RS845 Settings Menu IMPORTANT None of parameters in the RS4
4. gt Sensitivity 0 to 100 1 gt osse 10 00 to 10 00 Feet o gt Blankin gt Pulses 0 15 00 Feet 0 to 20 gt Max Distance 2 00 15 00 Feet e gt Trip Window Tripl Window 000 15 00Fet 15 00 Feet gt Gain Control gt Average Soft 0 Man l1 Auto 2 Hard 3 Soft4 Auto 1 to 32 0 00 15 00 Feet EN gt Trip Dist gt Window 0 00 15 00 Feet lo eee Type UT 1 000 15 00Fet 00 15 00 Feet ie Window gt Out of Range Samples l4 em gt Trip Type 2 3 iui _ l Output gt Sample Rate 1 to 5 Hertz 0 to 30 3 Far gt Multiplier 0 to 1 999 gt Temp Comp 0 0ff 1 On gt Distance gt Signal Strength 0 00 15 00 Feet a Remote Bytes S or 160 4 81 Feet 0 100 100 Best Pulses Sensitivity 94 1 47 INI Trip Status Green ON Red OFF gt Temperature IEEE Retry Time 30 to 180 Seconds Remote Callin 1 5 86400 Seconds 1 Time Readout in Celsius 24C P Trip2 Status Green ON Red OFF Figure 4 4 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 23 24 PARAMETER RANGE Sensitivity 0 10096 Sensitivity sets the level of gain that is applied to the echo When operating in AutoSense Hard Target o
5. Remote Bytes displays the number of bytes of data sent in the last communication between the LOE and the external website 8 bytes indicates a normal successful transmission 160 bytes indicates an error occured in the transmission Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Modbus Sensor Configuration Registers RS 485 Modbus Input Registers 399 SensorType SensorType 30300 el r 1767 Distance level 1 Top 30301 0 Distance level 2 Bottom 30302 Temperature C 3030330300 30304 69 69566 Volume 1 Data HR 30306 SS Volume 2 Data Se Version Number 30307 Signal Strength 30308 Sensor Voltage 30309 kelay Trip 1 Status 30310 pen pm Trip 2 Status Figure 4 15 This display only menu shows the contents of the Input Registers for the selected Modbus sensor See Figure 2 8 Registers used vary by sensor type Please see the user manual for each sensor for a full list of registers Detected Sensor Type Number and Sensor Model Number List Sensor Type 0 ON ADU KRWDN Model Number Sensor Type LOE 2126 9 LOE 6126 10 LOE 3136 11 LOE 7126 12 RST 5001 13 MPX E1 R1 2 floats 14 MPX E1 R1 1 float 15 PG 7 16 PG 10 Model Number PT 400 PT 500 L31 Level PT 400 PT 500 L5 Pressure DCR 1006A LPD MND RST 5003 4 AUS 7123 MTM 1000 Note This list represents sensors that interface with
6. 25 18 45 51 Feet 40 F anada DST Active Q 10 1 5 96 Google Search Figure 2 6 Figure 2 7 NOTE For further information on using your APG provided remote website please visit www apgsensors com support for a user manual or contact us at 1 888 525 7300 Logging on to the LOE Embedded Web Server The LOE s embedded webpage should now be open showing the Main Display page See Figure 2 8 This page lists the LOE any Modbus sensors attached to the LOE and displays each sensor s current reading The LOE is displayed as sensor 11 The configured sensor number for each Modbus sensor will show as its Sensor Number Every new Modbus sensor defaults to sensor number 1 Figure 2 8 IMPORTANT Multiple Modbus sensors added to the network simultaneously are all assigned the same sensor number 1 Sensors must be added to the network individually H Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 11 Click on Home to bring up the Menu page See Figure 2 9 The first menu link clicked during each session will prompt a User Name and Password login for the LOE See Figure 2 10 The default User Name is admin and the default Password is password Embedded WEB Server Network Security Labels Basic Parameters Application Settings RS 485 Network Settings RS 485 Modbus Holding Reg RS 485 Modbus Input 1 RS 485 Modbus Input 2
7. 60 Seconds Delay Between Call in Times meN LE E m bd LB ol Figure 4 22 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 37 38 The RS 485 Modbus Settings menu controls the settings for the Modbus sensors up to 10 attached to the LOE PARAMETER RANGE Baud Rate Checkboxes 2400 Baud 9600 Baud Baud Rate Checkboxes are used to select the baud rate of the of the sensors connected to the LOE All APG Modbus sensors communicate at 9600 Baud PARAMETER RANGE Numb of Sensors On Line 0 10 Numb of Sensors On Line sets the number Modbus sensors connected to the LOE This setting is not automatically populated or updated The user must change the setting manually Numb of Sensors On Line must always be equal or greater than the number of actual sensors attached to the LOE NOTE For best results set Numb of Sensors On Line to the highest number of num ber of sensor TO BE connected No further adjustments will be needed as those sensors are connected to the LOE PARAMETER RANGE Sensor Number to View 1 10 Sensor Number to View selects number of the sensor for the LOE to poll for populating the Main Menu and for editing parameters in the Modbus Holding Register menus PARAMETER RANGE New Sensor Number 0 No Change 1 10 New Sensor Number changes the sensor number assigned to the sensor selected by Sensor Number to View IMPORTANT
8. 753 7490 www apgsensors com sales apgsensors com
9. Diameter Parameter 4 Not Used Parameter 5 Not Used Application Type Tank Parameter Function 7 Pounds Parameter 1 Multiplier Linear Scaling Parameter 2 Unit Definition label Parameter 3 Not Used Parameter 4 Not Used Parameter 5 Not Used Pounds allows for a multiplier Parameter 1 to be applied to the calculated level measurement creating a linear scalar as the output to configured read ing on the Main Display Page Such a multplier could convert the distance or level measurement of a tank with simple geometry into a measurement of weight Application Type Tank Parameter Function 8 User Defined Units Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Not Used Not Used Not Used Not Used Not Used User Defined Units is not used by the LOE Application Type 8 can be selected but after leaving the Application Parameters Menu Application Type reverts to 0 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Application Type Tank Parameter Function 9 Vertical Oval Parameter 1 Tank Length Distanee Tank Parameter 2 Tank Depth Parameter 3 Tank Width Parameter 4 Not Used Empty Parameter 5 Not Used Distance Lo a Length Application Type Tank Parameter Function Full 10 Horizontal Oval Parameter 1 Tank Length Distance Tank Parameter 2 Tank Depth Es Parameter 3 Tank Width Distance Parameter 4 Not Used Parameter 5 Not Used Basic Parameters
10. sensors must be powered 24V B A GND Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com ME IDE M independently POE Power over Ethernet Wiring To Network Connection P LAN LAN DC 5 5 En PM LI Uv p POE OQOG V Power i Injector E29 M AV B A GND J Terminal inside housing supplies 24 Vdc to power attached Modbus devices To AC when powering the LOE power from a POE source Modbus Sensor Daisy chain Wiring 270 Q terminating resistor NOT internal to LOE di TS p RS 485 are NOTE Power terminals for 24V and GNDXA B 24 GND can only be used to power Modbus s sensors if LOE is powered via POE If LOE is powered via 12 28 VDC supply I Modbus sensors must be powered I f independently I M b p Na TRT o M M d Note Terminating resistor size recommended M based on input resistance of LOE Length B of cable and overall impedence of network may FY TS SE Use shielded cable necessitate a different size resistor Y F I Trunk Line Sensor Line Drops 2700 terminating resistor at la
11. various APG Modbus software packages Not all interface with the LOE 32 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG RS 485 Modbus Holding 1 TT EIIIIISILO O NNN o 7 Application Type Distance 0 Distance 1 Level 2 7 9 11 Volume 3 Vometms Galom mv EEE See Tm a FiterWndow O0toMaxDisanemm Ose 3m00 03290mm FalSafeDelay 19999 0 Figure 4 16 This menu shows the contents of the first set of Holding Registers for the selected Modbus sensor See Figure 2 8 The register names and value restrictions are automatically configured for the type of sensor detected See Figure 4 15 Because register name and use varies by sensor including a full breakdown of the registers in this manual would be counterproductive Please see the user manual for each sensor for a full list of registers H Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 33 RS 485 Modbus Holding 2 442 o Foatwadw 155 4004 b nd Float Offset 32000t032000mm 4006 0 Volt 4maSetPoint OtoMexDisanemm 4008 o OVot 4maCaibrain 0405 40429 0 SVolt 20maCalibration 0405 40430 mo Trpivaue OtoMexDisanemm 40433 200 Trp2vaue OtoMexDisan
12. 0 upper bits Sensor Trip 2 Alarm 30310 lower bits Sensor Trip 2 Status 30311 upper bits Sensor Trip 3 Alarm 30311 lower bits Sensor Trip 3 Status 30312 upper bits Sensor Trip 4 Alarm 30312 lower bits Sensor Trip 4 Status This is the list of generic Input Registers for polling the LOE and any connected sensors Actual registers used vary by sensor Please see the user manual for each sensor for a full and accurate list of registers NOTE For more information about Modbus RTU please visit www modbus org Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 15 Modbus Programming of Individual Sensors The LOE does NOT support full Modbus programming of attached sensors Full control and configuration of individual sensors is supported through the LOE s embedded web server and through your APG provided webpage www levelandflow com NOTE For any APG sensor user manual please visit http apgsensors com support Chapter 4 LOE Embedded Web Server Accessing the LOE Embedded Web Server See the Software Setup section of chapter 2 pages 9 11 for instructions for accessing and signing into the LOE embedded web server Navigating the LOE Embedded Web Server The LOE embedded web server has two primary screens the Main Display Page Figure 4 1 and Menu Page Figure 4 2 and a screen for each of 9 submenus The submenus can be understood in three groups LOE Sensor Inpu
13. 85 Settings menu automatically update Each one must be manually configured e Removal Instructions Disconnect power to the LOE first Disconnect network connection Disconnect any sensors relays and switched inputs Remove the LOE and store it in a dry place at a temperature between 40 F and 180 F Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Chapter 3 Programming with Modbus TCP IP Modbus Polling via Ethernet with Modbus TCP IP Using the LOE s IP address and port number 502 readings can be polled from the LOE for any attached sensors via RS 485 Modbus commands Up to 14 16 bit Input Registers beginning with register 299 can be polled with a single command Below is a sample Modbus command illustrating the necessary syntax Example 00 01 Transaction Identifier 00 00 Protocol Identifier 00 06 Message Length 6 bytes to follow OB The Reporting Unit Identifier sensor number 0B hex 11 04 The Function Code 04 read Input Registers 01 2b The Data Address of the first register requested 12E hex 1 303 00 02 The total number of registers requested read 2 registers i e 303 to 304 Byte order hex values 00 01 00 00 00 06 OB 04 01 2E 00 02 Notes Reporting Unit indicates the sensor reading being polled from the LOE in hex 01 OA are for Modbus sensors 1 10 attached to the LOE OB i e sensor 11 reads the values from the LOE sensor S
14. For Hard and Soft Target the user sets maximum Sensitivity and Pulses but the overall gain is either ramped up slowly Hard Target or quickly Soft Target by the sensor PARAMETER Average RANGE 1 32 Average sets the number of qualified samples to average for the displayed reading Qualified samples are placed in a first in first out buffer the contents of which are averaged for Distance The larger the number of qualified samples being averaged the smoother the output reading will be and the slower the reading will be to react to quick changes Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 25 PARAMETER RANGE Window 0 Sensor Maximum Window determines the corresponding physical range for qualified samples based on the current Distance Samples beyond the Window range of the current Distance will not qualify unless the average moves Samples outside the extents of the Window are written to the Out of Range Samples buffer See Figure 4 8 Example Window 6 Inches Out of Range Samples 10 Samples are rejected within this area unless they persist for 10 consecutive samples Samples are rejected within this area unless they persist for 10 consecutive samples Current value Aic Min Reading of Distance Max Reading P Figure 4 8 PARAMETER RANGE Out of Range Samples 0 250 Out of Range Samples sets the number of consecutive samples outside the Window necessary to
15. LOE Ultrasonic Level Sensors User Manual Web Enabled Controller Doc 9004258 Rev B 09 15 Table of Contents Mode seer ni Warranty and Warranty Restrictlons smnnnrnnnvnnvvnnnnnnvrnnnvnnvennnvnnvnnnnnnnvnnnnnnnennnennn iv Chapter 1 Specifications and Options essen 1 Dimens wc 1 IS dog Kotei 0 1 MM METTRE 2 3 Model Number Configurator xrsesvnnvnvnnvnvvvrnonnrnrnnenennnnenennenennnnenennennnnennnnennnnenennenennenenennenennenener 3 System Wiring Diagrams rnnrnvrnvnnrnnvnonnvnnonnnnvnnnnnvnnnnnnnvnnennennnnennennennnnennennennnnnnnennennennnnennennene 4 6 Chapter 2 Installation and Removal Procedures and Notes 7 Tools Needed peer 7 Connection m nenene 7 El ctrical mstallatio PC eee 7 hustallalon NOS conet een 8 Mounting IDSEEUCHIDHS uepurinpi ERR UP RCEQUR UD IRUYMEN COR VEx NM RUSEN RE PUR FDIRRU nupasssanesdocaionanovesnanuaipemesscaniaiens 8 OBL VU AN SEN He 9 13 Removal Instructions xcac ac nesses sees cecec cect wcesceveccade ves tcesenc pcecetencecuedctpcsvseeanuseeveceseeesdvimeecececcecevtniees 13 Chapter 3 Programming with Modbus TCP IP sess 14 Modbus Polling via Ethernet with Modbus TCP IP sess 14 15 LOE Generic Modbus Register List rsmnnnnnnnvrnonnvnnrnvnnennrnvnnennonnvnvnnnnnvnnnnnnnnnnnnnnnnnnennenne
16. When Change is pressed to assign a new sensor number Sensor Num ber to View DOES NOT update PARAMETER RANGE RS485 Sample Rate 1 60 Seconds RS485 Sample Rate determines how often the LOE polls the selected Modbus sensor Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Chapter 5 Maintenance General Care Your LOE series controller is very low maintenance and will need little care as long as it is installed correctly However in general you should Avoid applications for which the sensor was not designed such as extreme temperatures contact with incompatible corrosive chemicals and fumes or other damaging environments nspect the threads whenever you remove the sensor from duty or change its location Troubleshooting Should you have problems with your LOE here are some troubleshooting steps Checkthe received signal strength See Figure 4 9 If the signal strength is low alternately increase Pulses and Sensitivity See Figure 4 4 until the signal strength improves Ensure Temperature Compensation See Figure 4 4 is On set to 1 Setthe Gain Control to AutoSense See Figure 4 4 Ensure that Blanking See Figure 4 4 is accurately set to account for any unwanted targets between the sensor and the closest acceptable target See Figures 4 5 4 7 APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 39 G Calibra
17. al Parameter 3 Not Used ru Bottom Parameter 4 Not Used Distance Parameter 5 Not Used Empty Distance Bottom Radius 20 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Application Type 3 Standing Cylindrical Tank Parameter Parameter 1 Function Tank Diameter Diameter Tank with Parameter 2 Bottom Radius TO Conical Parameter 3 Cone Length Height Fun Bottom Parameter 4 Not Used Distance Parameter 5 Not Used Empt Distnte Cone Length aa Cone Diameter Application Type Tank Parameter Function 4 Standing Rectangular Parameter 1 Tank X Dimension a Tank with Parameter 2 Tank Y Dimension Chute Parameter 3 Application Type Parameter 4 Parameter 5 Tank Parameter Chute X Dimension Chute Y Dimension Empty Chute Length Height Distance Chute Length Na Chute Y Chute X Function 5 Horizontal Cylindrical Tank with Spherical Ends Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Tank Length Tank Diameter Radius of Ends Not Used Not Used Full Distance Diameter Empty Distance End Radius N Length Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 21 22 Application Type Tank Parameter Function 6 Spherical Tank Parameter 1 oues S EM e Full Tank Diameter Parameter 2 Not Used Distance Parameter 3 Not Used PD
18. ammable 5 Hz maximum 200 ms Ethernet TCP IP Modbus Ethernet TCP IP via embedded webserver LAN only Ethernet TCP IP to APG provided website 2 Isolated Solid State Relays RS 485 Modbus up to 10 slave sensors 48 VDC via POE requires injector or switch 12 28 VDC 40 mA 48 VDC 80 mA 24 VDC 130 mA Max Isolated SSRs 2 0 W Max 0 25 of detected range 0 1 inch 2 54 mm 40 to 60 C 40 to 140 F Yes IP65 PVDF PC PET Ceramic PVDF faced Mounting LOE 2126 LOE 3136 LOE 6126 Compatible APG Modbus Senors Ultrasonic Magnetostrictive Pressure Controllers Model Number Configurator Part Number LOE 2 NPT 3 NPT 2 NPT MNU MPX E1 MPX R1 PT 400 L5 PT 400 L31 PT 500 L5 PT 500 L31 DCR 1006A MND A A Model 2126 1 25 ft 305mm 7620mm 69 kHz 2 NPT threads 3136 1 5 40 ft 458mm 12192mm 43 kHz 3 NPT threads 6126 0 6 15 ft 178mm 4572mm 69 kHz 2 NPT threads APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com System Wiring Diagrams External 12 28 VDC Source Wiring we T a I 1012 28 VDC Power Supply N P4 Am cm gm TRAN 6666 J pooo ETHERNET PORT NOTE Power terminals for 24V and GND can only be used to power Modbus sensors if LOE is powered via POE If LOE is powered via 12 28 VDC supply Modbus
19. at the forward end of Blanking If Offset is more negative than Blanking is positive the net difference will be a loss in sensor maximum range See Figure 4 7 PARAMETER RANGE Max Distance Determined by sensor model Maximum Distance sets the maximum acceptable signal range up to the physical maximum of the sensor measured from the Zero Point Signals beyond the Maximum Distance are ignored Under Loss of Echo conditions the Distance reading will display the Maximum Distance LOE Readings gt Distance 0 00 15 00 Feet 481 Feet gt Signal Strength 0 100 100 Best Pulses Sensitivity 94 1 47 gt Temperature Readout in Celsius 24C Figure 4 9 Reading Type Range Distance Determined by model Distance displays the distance from the sensor to the detected target in the units selected in the Units parameter in the Application Parameters Menu See Figure 4 3 This reading is always Distance regardless of the Application Type selected in the Application Parameters Menu Reading Type Range Signal Strength 0 100 Signal Strength displays the strength of the signal being received by the sensor 0 represents the lowest quality signal and 100 represents the highest quality Reading Type Range Temperature Temperature displays the current temperature of the thermal device in the LOE sensor body Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsenso
20. automatically adjust the current Distance and move the Window PARAMETER RANGE Sample Rate 1 5Hz Sample Rate is the number of sample readings taken by the LOE every second PARAMETER RANGE Multiplier 0 1 999 Multiplier is used to calibrate the LOE sensor for variations in the speed of sound due to variations in atmospheres The default of 1 000 is used for most applications PARAMETER RANGE Temp Comp 0 Off 1 On Temperature Compensation activates or deactivates the LOE s internal temperature compensation circuit The speed of sound changes with changes in temperature therefore changes in temperature can affect distance measurements These effects can be minimized by activating temperature compensation 26 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG PARAMETER RANGE Offset 10 ft 10ft Offset is used to change the Zero Point of the LOE sensor The Zero Point of the sensor is the point from which the calculated distance is measured When the Offset is set to 0 the Zero Point of the sensor is at the face of the transducer See Figure 4 5 A positive setting will move the Zero Point forward in front of the sensor face See Figure 4 6 Setting the Offset to a negative number will move the Zero Point backward behind the sensor face See Figure 4 7 In all cases Blanking is measured from the end of Offset and the effective measurement zone of the sensor begins
21. e server type http loe xxx Some networks will block this direct access to the LOE If this is the case you will need to use the IP address of your LOE to access the embedded web server The IP address can be obtained two ways ask your local network administrator or logon to your APG provided website www levelandflow com H Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 10 Accessing LOE Embedded Web Server via Local IP Address Log on to your APG provided website and a list of sites will be displayed on your screen see Figure 2 4 Select the site where the new LOE is installed From the list of sensors at thie site select the sensor with the serial number that matches the new LOE See Figure 2 5 APG Automation Products Group Inc APG Currently Logged In John Doe 1025 west 1700 North irr eim 01 2012 Logan UT 84321 i 888 525 7300 sales apgsensors com www apgsensors com Sites Profile Logout r ABC Site 1 Greenville John Doe 435 753 7300 4 sensors APG Automation Products Group Inc Current Sites 3 ABC Site 2 Franklin John Doe 435 753 7300 5 sensors ACB Site 3 Sprinafield John Doe 435 753 7300 4 sensors View All Sensors by Site Figure 2 4 APG Currently Logged In John Doe 1025 west 1700 North Date October 01 2012 Logan UT 84321 888 525 7300 sales apgsensors com SORES ww
22. e 4 12 Trip Condition 3 Far Far activates the Trip whenever the Distance is greater than the Trip Distance setting Trip Condition 4 Inclusive Exclusive activates the Trip whenever the Distance is greater than the Trip Distance setting AND less than the Trip Distance Trip Window settings Trip Condition 5 Hysteresis Far Hysteresis Far activates the Trip whenever the Distance becomes greater than the Trip Distance Trip Window settings The Trip remains activated until the Calc Dist Level Volume becomes less than the Trip Value setting The Trip remains off until the Distance becomes greater than the Trip Distance Trip Window settings again APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 29 30 Trip Condition 6 Disable Trip Relay 16 Turn on Trip Relay 26 N A Disable de activates the Trip or SS Relay output Trip Condition 7 Loss of Echo Loss of Echo activates the output when the maximum calculated reading is reached Trip Condition 8 Timed Interval Timed Interval activates the output for a set amount of seconds every set amount of minutes See Figure 4 13 When Trip Type is set to 8 Trip Distance and Trip Window are changed to Interval Time minutes and On Time seconds INTERVAL TIME in minutes ON TIME in seconds Relay OFF open Relay ON closed I Figure 4 13 Trip Condition 9 Abrup
23. ee Figure 2 8 Unused registers i e those not associated to an attached sensor will return zeros when polled Function Code 04 reads the Input Registers No other functionality e g polling from or writing to Hold ing Registers is supported via Modbus TCP IP with the LOE Complete control functionality is available through the embedded web server and through your APG provided website www levelandflow com Data Address of registers decimal to hex minus 1 conversion Decimal Address Hex minus 1 Decimal Address Hex minus 1 299 12A 306 131 300 12B 307 132 301 12C 308 133 302 12D 309 134 303 12E 310 135 304 12F 311 136 305 130 312 137 14 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Total number of registers requested up to 14 given in hex 3t of Registers Hex equivalent 3t of Registers Hex equivalent 01 01 08 08 02 02 09 09 03 03 10 OA 04 04 11 OB 05 05 12 OC 06 06 13 OD 07 07 14 OE LOEGeneric Modbus Register List Input Registers 0x04 Register Returned Data 30299 Sensor Type 30300 Distance Level 1 Top in mm unsigned 30301 Distance Level 2 Bottom in mm unsigned 30302 Sensor Temperature Reading in C signed 30303 30304 Calculated 1 raw 30305 30306 Calculated 2 raw 30307 upper bits Version 30307 lower bits Signal Strength 30308 Battery Voltage 30309 upper bits Sensor Trip 1 Alarm 30309 lower bits Sensor Trip 1 Status 3031
24. emm 485 6e TI mete 9 40438 40439 o Parameter2Data NotUsd 0214748367mm 40442 40443 o Parameter4Data NotUsed 0214748367mm TENE Figure 4 17 This menu shows the contents of the second set of Holding Registers for the selected Modbus sensor See Figure 2 8 The register names and value restrictions are automatically configured for the type of sensor detected See Figure 4 15 Because register name and use varies by sensor including a full breakdown of the registers in this manual would be counterproductive Please see the user manual for each sensor for a full list of registers 34 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG LOE Utilty Menus Network Settings gt LAN IP Address 10 1 5 33 gt Remote IP Address 174 127 124 29 gt Subnet Mask 255 255 0 0 gt Default Gateway 1011 1 gt Primary DNS Server 10 1 3 1 gt Secondary DNS Server 10 132 gt MAC Address 0332180177 gt Port Number 6700 gt External Website Access On Checked On gt DHCP Success Checked On gt Alarm Filter On Checked On gt Domain Name www levelandflow com gt Domain Name IP Address 174 127 124 29 Undo Home Figure 4 18 The Network Settings are provided for advanced users only and should not normally requ
25. ire changes Each LOE ships with the DHCP enabled which means it will automatically connect to the the APG provided re mote website usually www levelandflow com and configure its own Network Settings when plugged into a port providing direct internet access H Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 35 Security Settings gt User Name gt Password Figure 4 19 The Security Settings allow users to set their own user name and password for logging into the embedded webpage Labels e Pee Analog Input Description gt Modbus Sensor 1 Description Figure 4 20 The Labels menu allow users to create custom labels for the Main Menu the LOE and the sensors attached to the LOE The Analog Input Description is for the LOE itself 36 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG gt Main Table Title LOE System gt Analog Input Description Main LOE Tank Main LOE Tank When labels are created in the Labels menu they will be reflected on the Main Menu page See Figure 4 21 RS 485 Network Settings 2400 Baud Figure 4 21 Checked or UnChecked 32400 Baud 9600 Baud Checked or UnChecked 9600 Baud Numb of Sensors On Line Sensor Number to View 0 to 10 1to 10 New Sensor Number O0 No Change or 1 to 10 1 to
26. istance sets the distance from the LOE sensor Zero Point See Figures 4 5 4 7 to the full level of the vessel being monitored Not used when Application Type is set to 0 Value PARAMETER RANGE Empty Distance 0 Sensor Maximum Empty Distance sets the distance from the LOE sensor Zero Point See Figure 4 5 4 7 to the empty level of the vessel being monitored Not used when Application Type is set to 0 Value Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG PARAMETER RANGE Application Type 0 Value Distance 1 Level 2 Volume of Standing Cylindrical Tank with or without Hemispherical Bottom 3 Volume of Standing Cylindrical Tank with or without Conical Bottom 4 Volume of Standing Rectangular Tank with or without Chute Bottom 5 Volume of Horizontal Cylindrical Tank with or without Spherical Ends 6 Volume of Spherical Tank 7 Pounds Linear Scaling 8 User Defined Units 9 Volume of Vertical Oval Tank 10 Volume of Horizontal Oval Tank Application Type is used to choose the parameter configuration to convert the distance of Distance into the configured reading on the Main Display Page See Figure 4 1 After selecting an Application Type and press ing Change the Application Parameters menu updates to reflect the parameters of the chosen application See Tank Parameters for an explaination of each Application Type and its associated parameters PARAMETER RANGE Vo
27. larm Designates the active trip point as a web alarm condition To initiate web alarm whenever the Trip Condition 3 is ON Trip Type would be set to 13 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Alarm Type TRIP TRIP 2 Inactive Alarm DISTANCE WINDOW Designates an inactive trip point as a web alarm condition To initiate a web alarm whenever the Trip Condition 3 is i ON OFF OFF Trip Type would be set to 23 IQ OED ee See Trip Condition 0 Near ON OFF ON TRIP TYPE 1 EXCLUSIVE gt lt gt lt gt Near activates the Trip whenever the Distance is less than the Trip Distance setting Trip Condition TRIP TYPE 2 ON ON 1 Exclusive HEER ee A og lt OFF e Exclusive activates the Trip whenever the Distance is less than the Trip Distance setting OR greater than the Trip OFF ON P P TRIP TYPE 3 Distance Trip Window settings FAR lt gt lt gt Trip Condition 2 Hysteresis Near OFF ON OFF TRIP TYPE 4 INCLUSIVE lt lt gt lt gt lt gt Hysteresis Near activates the Trip whenever the Distance becomes less than than the Trip Distance setting The Trip remains activated until the Distance becomes greater than the Trip Distance Trip Window settings The Trip then HYSTERESIS lt lt 2 gt remains off until the Distance becomes less than the Trip ON Distance setting again S ON gt Figur
28. lume Units 1 Feet 2 Million Feet 3 Gallons 4 Meters 5 Liters 6 Inches 7 Barrels Volume Units selects the units of measure for the configured reading on the Main Display Page See Figure 4 1 when a volumetric application is selected The settings is not used when the Application Type is set to 0 1 7 or 8 PARAMETER RANGE Units 1 feet 2 inches 3 meters Units is used to select the units of measurement for distance or level applications The units will also determine the resolution of Basic and Application Parameters The resolution is feet 0 01 inches 0 1 and meters 0 001 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 19 Tank Parameters Application Type Tank Parameter Function 0 Distance Parameter 1 Not Used Parameter 2 Not Used Parameter 3 Not Used Parameter 4 Not Used Parameter 5 Not Used Distance factory default measures the distance from the Zero Point of the Distance LOE sensor to the target surface TA Application Type Tank Parameter Function 1 Level Parameter 1 Not Used T Parameter 2 Not Used Parameter 3 Not Used Parameter 4 Not Used Parameter 5 Not Used Level calculates the depth or level of the vessel being monitored based on the Full Distance and Empty Distance Application Type Tank Parameter Function ped 2 Standing Cylindrical Parameter 1 Tank Diameter Tank with Parameter 2 Bottom Radius Hemispheric
29. nnenennennene 15 Modbus Programming of Individual Sensors esses 16 Chapter 4 LOE Embedded Web Server esses 16 Accessing the LOE Embedded Web Server eese 16 Navigating the LOE Embedded Web Server 2 22 ssssscecceeeceeeeeeeeeeeeeeeeeeeeeeteeaeeeeeeneeees 16 17 LOE Sensor Input Configuration Submenus xsrnrnnrnvnvnnvnvnnrnvrnennnnnnennenernvnenennenennenvenennnnr 18 31 Modbus Sensor Configuration Registers mrsrrnrnvnnrnvnvrnvnornvnvrnenonnnnennenennvnerennenennenennenenn 32 34 LOE Utility Menus o orvesvaipitt rien eirk OR n Rx ERXER EF XRETR E MR EN KR EDEN VEN RUE ER 35 38 Chapter 5 Maintenance rnsnrnnvrnnnnnnvnnnnnnnvnnnvnnnvnnnennnvnnnennvnnnnennvnnnnennvnnnnnnnvnnnvnnnennneenn 39 General EE EE EE eee 39 Troubleshooting e seeeias piri Epor Wood Varucerpa RERRENIE E VK NER PEE ERA VEDO KR RE eee 39 Calibration C H 40 Repair and Be Sr 40 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG LI Introduction Thank you for purchasing an LOE Ultrasonic Level Sensor and Web Enabled Controller from APG We appreciate your business Please take a few minutes to familiarize yourself with your LOE and this manual The LOE Ultrasonic Level Sensor and Web Enabled Controller offers a wide degree of integrated flexible remote and local control and monitoring f
30. or other agent or representative of APG which is not specifically set forth herein shall be binding upon APG APG shall not be liable for any incidental or consequential damages losses or expenses directly or indirectly arising from the sale handling improper application or use of the goods or from any other cause relating thereto and APG s liability hereunder in any case is expressly limited to the repair or replacement at APG s option of goods Warranty is specifically at the factory Any on site service will be provided at the sole expense of the Purchaser at standard field service rates All associated equipment must be protected by properly rated electronic electrical protection devices APG shall not be liable for any damage due to improper engineering or installation by the Purchaser or third parties Proper installation operation and maintenance of the product becomes the responsibility of the user upon receipt of the product Returns and allowances must be authorized by APG in advance APG will assign a Return Material Authorization RMA number which must appear on all related papers and the outside of the shipping carton All returns are subject to the final review by APG Returns are subject to restocking charges as determined by APG s Credit Return Policy Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Chapter 1 Specifications and Options Dimensions LOE 2126 LOE 6126
31. or your system The LOE can control up to 10 APG Modbus sensors any combination of level pressure magnetostrictive and ultrasonic and two output relay terminals All readings are available for control and monitoring via TCP IP for local or remote network access The LOE also had flexible power options it can use either POE or an independent 12 28 VDC power source Reading your label Every APG controller comes with a label that includes the controller s model number part number and serial number The LOE label also indicates the default IP address subnet mask and mac address Please ensure that the model number on your label matches your order APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com mac Warranty and Warranty Restrictions APG warrants its products to be free from defects of material and workmanship and will without charge replace or repair any equipment found defective upon inspection at its factory provided the equipment has been returned transportation prepaid within 24 months from date of shipment from factory THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT EXPRESSLY SET FORTH HEREIN WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE No representation or warranty express or implied made by any sales representative distributor
32. r Soft Target see Gain Control Sensitivity sets an upper limit for the amplification that can be applied to the echo If operating in Manual this parameter sets the gain When using manual gain control set Sensitivity to the minimum value that will allow the target to be reliably tracked through the full range of expected environmental conditions IMPORTANT Parameter values stored on the LOE will not update until the Change button is clicked PARAMETER RANGE Blanking Determined by sensor model Blanking sets the blanking distance which is the zone from the Zero Point of the sensor to the point from which the first echo will be accepted While blanking distance can be used to ignore unwanted targets such as welds seams pipe fittings or gaskets between the sensor and the closest acceptable target level such objects generally create additional reflections and echoes which are hard to filter out More often blanking distance is used for a sensor installed in a stand pipe Because of the physical properties of an ultrasonic sensor objects cannot be detected closer than approximately 1 foot from the face of most transducers 7 inches for LOE 6126 However this distance varies according to how much energy is being transmitted Pulses and the installation IMPORTANT Blanking is always measured from the Zero Point of the sensor See Fig ures 4 5 4 7 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com
33. rs com 27 LOE Trip Outputs and Settings 28 gt Tripl Dist 0 00 15 00 Feet 2 54 P Trip Window 0 00 1500Feet 104 gt Trip Type 30 i Output 0 to 29 3 Far 3 P Trip Dist 0001500Fee 50 gt Trip Window 0 00 15 00 Feet 1 04 P Trip Status Green ON Red OFF Tripi ON gt Trip Type 0 to 30 3 F 3 Output on TK P Trip Status Green ON Red OFF TPI ON Figure 4 10 Figure 4 11 The LOE has 2 output relays that can be configured to turn on or off based on the Distance reading of the sensor Trip Type Outputs are configured with two independent digits the first for Alarm Type Blank 1 or 2 and the second for Trip Condition 0 5 7 or 9 PARAMETER RANGE Trip Distance 0 Sensor Max Distance Trip Distance sets the value of the primary trip position which is closest to the Zero Point of the sensor PARAMETER RANGE Trip Window 0 Sensor Max Distance Trip Window sets the value from the primary trip position to the secondary trip position which is farther from the sensor s Zero Point Alarm Type Blank No Alarm Designates that no alarm is to be activated or deactivated on the remote APG provided website i e www levelandflow com for the indicated Trip Condition To initiate only the visual Trip Status indicator See Figure 4 11 for Trip Condition 3 Trip Type would be set to 3 Alarm Type 1 Active A
34. sales apgsensors com APG Effective Measurement Zone Zero Blanking Point Distance Offset 0 Figure 4 5 Sensor Max Offset Effective Measurement Zone l ji Zero Blanking Sensor Point Max Distance Offset 0 Figure 4 6 Effective Measurement Zone Ms pe Offset Zero Blanking Sensor Point Max minus Offset Offset lt 0 Figure 4 7 Sensor Max Distance PARAMETER Pulses RANGE 0 20 Pulses sets the maximum number of pulses the sensor can transmit when operating in AutoSense Hard Target or Soft Target see Gain Control or sets the number of pulses when operating in Manual The more pulses that are sent in a burst the stronger the returning echo When operating in Manual increase the strength of the transmission by increasing Pulses for detecting soft targets in damping environments In acoustically active environments or small enclosed areas decrease Pulses to reduce multiple echoes PARAMETER Gain Control RANGE 0 Manual 1 AutoSense 2 Hard Target 3 Soft Target Gain Control selects the control mode for the LOE sensor s gain settings Sensitivity and Pulses In AutoSense the sensor automatically adjusts the sensitivity and pulses for the best quality return signal Manual Hard Target and Soft Target are user controlled scenarios In Manual the user is in full control of Sensitivity and Pulses
35. st sensor 1 Sensor 2 Sensor 3 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com System Overview LOE with Modbus network SSR s and Internet Connection Server Hosting Website and Logged Data Computer on Internet Network Internet Connection Computer on Local Network Connection to Internet e e au qm sr MNU Ultrasonic Sensors Solid State Relays IP Co inm MP NM et MN MP Magnetostrictive Float Level Sensors 6 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Chapter 2 Installation and Removal Procedures and Notes Tools Needed Flat head screwdriver to remove knockouts for cables e If you are using a stand pipe to mount your LOE you will probably need tools to install the stand pipe Forany attached Modbus sensors please consult each sensor s user manual for installation notes and instructions NOTE For any APG sensor
36. t Change TRIP TYPE O NEAR TRIP TYPE 1 EXCLUSIVE TRIP TYPE 2 HYSTERESIS NEAR TRIP TYPE 3 FAR TRIP TYPE 4 INCLUSIVE TRIP TYPE 5 HYSTERESIS FAR TRIP TRIP DISTANCE WINDOW ON OFF le gt ON OFF ON le gt ON ON OFF lt gt OFF OFF ON gt lt gt gt OFF ON OFF le gt OFF OFF ON gt Figure 4 12 Abrupt Change activates the output whenever a user defined maximum rate of level change change in distance or level divided by elapsed time is exceeded Trip Distance defines the distance and Trip Window defines the time Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com External Website Communication Status gt Retry Time 30 to 180 Seconds 30 P Remote Call in 1 to 86400 Seconds 60 l Time 8 or 160 8 gt Remote Bytes Figure 4 14 The LOE embedded web server includes one parameter and two status reports for communication with the remote APG provided website i e www levelandflow com PARAMETER RANGE Retry Time 30 180 Seconds Retry Time sets the time delay in seconds between attempts by the LOE to contact the external website DISPLAY RANGE Remote Call in Time 1 86400 Seconds Remote Call in Time displays the duration of the last communication between the LOE and the external website DISPLAY RANGE Remote Bytes 8 or 160 Bytes
37. t Configuration Submenus Basic Parameters Application Settings Modbus Sensor Configuration Registers RS 485 Modbus Input Reg RS 485 Modbus Holding 1 RS 485 Modbus Holding 2 LOE Utility Menus Network Security Label RS 485 Network Settings The Menu Page also has a link back to the Main Display Page 16 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG Figure 4 1 Embedded WEB Server Main Display Network Security Labels Basic Parameters Application Settings RS 485 Network Settings RS 485 Modbus Holding Reg RS 485 Modbus Input 1 RS 485 Modbus Input 2 Figure 4 2 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 17 LOE Sensor Configuration Submenus LOE Application Settings gt Full Distance 0 00 15 00 Feet 44 gt Application Type HoriCylTank Spericalends gt Volume Units Gallons Ss gt Tank Parameter 1 TankLengh P Tank Parameter3 Radin of Hemisphere Ends 95 T gt Tank Parameter 4 Not Used 100 8 gt Tank Parameter 5 ____ NotUsed P Units 1eet 2 inches 3 meters Figure 4 3 The Application Parameters menu configures the application specific parameters applied to the calculated reading from the LOE sensor PARAMETER RANGE Full Distance 0 Sensor Maximum Full D
38. tion This procedure uses targets at known distances to calibrate the LOE sensor s accuracy A wall or other large flat object is recommended for the long range target Pointthe sensor at a target at a known distance near the maximum range of the sensor See Figure 5 1 e Adjust the Multiplier value until the distance reading on the sensor matches the actual measured dis tance to the target See Figure 4 4 e Point the sensor at a target near the minimum measurement range 1 plus any Blanking distance See Figure 5 2 Adjust the Offset value until the distance reading on the sensor matches the actual measured distance to the target See Figure 4 4 Repeat previous two steps until no further adjustment is required measure measure Figure 5 1 Figure 5 2 Repair and Returns Should your LOE require service please contact the factory via phone email or online chat We will issue you a Return Material Authorization RMA number with instructions Phone 888 525 7300 Email sales apgsensors com Online chat at www apgsensors com Please have your LOE s part number and serial number available See Warranty and Warranty Restrictions for more information 40 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG APG Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com 41 Automation Products Group Inc Tel 1 888 525 7300 Fax 1 435
39. user manual please visit http apgsensors com support Connection Notes Upto 10 Modbus sensors can be connected to the LOE in any combination SSR s are rated for 400V 130mA max IMPORTANT Each Modbus sensor must be connected to the network individually and assigned a unique Sensor Number before the next sensor can be added Electrical Installation e Use flat head screwdriver to remove knockouts on either side of LOE housing nsert included cable fittings in knockout holes Connect any output relays first Connect LOE to Ethernet network Connect independent 12 28 VDC supply if not using POE Connect and set up one Modbus sensor at a time IMPORTANT Multiple Modbus sensors added to the network simultaneously are all assigned the same Modbus address sensor number 1 Sensors MUST be added to the network individually Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Installation Notes Mount your LOE sensor so that it has a clear perpendicular sound path to the surface being moni tored Your sensor should be mounted away from tank or vessel walls and inlets See Figure 2 1 The sound path should be free from obstructions and as open as possible for the 9 off axis beam pattern e Ifyou are using a stand pipe please see our guide to stand pipes on our website http www apgsensors com about us blog how to install a stand pipe
40. w apgsensors com Sites Profile Site Name ABC Site 1 Location Greenville Route ABC Site 1 Sensors Site Information Contact John Doe Phone 435 753 7300 E mail johndoe apgsensors com 4 Sensor 1 Liquid A L000000016 2009 09 08 09 29 30 4941 Gallons Volume 93 Sensor 2 Liquid B L000000018 2009 03 11 15 25 18 45 51Feet Value 91 Sensor 3 Liquid C L000000022 2010 11 03 14 45 12 0 Gallons Volume 0 Sensor 4 Liquid D L000000030 2009 12 04 09 38 06 15Feet Value 100 Save as Excel File Printable view All sensor data for today readings in desending order Set site s Google map location Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com salesQapgsensors com Current Alarms for ABC Site 1 0 Sensor Site Serial Alarm Date Time Reading Figure 2 5 mu APG On the Sensor Information screen you will see APG HITS 1025 west 1700 annu Logan UT 84321 the IP Address of the newly installed LOE See mu 888 525 7300 s Automation Products Group Inc www apgsensors Figure 2 6 Type the LOE s IP address into your browser s address bar See Figure 2 7 Site Name Location Greenville Route Serial 1000000018 New Tab User Description1 User Description2 Liquid B Model LOE 2126 Serial Number L000000018 Units Feet Interval hh mm ss 00 05 00 BE mem eO Mountain Tim iP Address 10 1 5 96 d mibineiietemet Trom sensor Mar 11 2009 09