Home
AIRREX DEHUMIDIFIER
Contents
1. 8 AIRREX Fora Happy amp Healthy Life AIRREX DEHUMIDIFIER USER S MANUAL ADH 1000 gt Thank you for purchasing an AIRREX DEHUMIDIFIER BEFORE operation please read this user s manual carefully gt Keep this manual readily available gt It is ESSENTIAL that you read the NOTES ON SAFETY carefully before use and follow them at all times gt This Dehumidifier is specified for use on a 230V 50Hz single phase power supply You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician gt The Warranty form is on Page 15 Please complete it now and keep in a safe place gt We have a policy of continual improving to our products The contents features and specifications in this manual are therefore subject to change without notice 8 AIPREXK esmas parace EDS Add For a Happy amp Healthy Life TABLE OF CONTENTS m SAFETY INSTRUCTIONS DESCRIPTION Front View Back View Control Panel OPERATION Running amp Stop Humidity Control Operation How to Set the Off Timer Error and Warning Indicators Continuous Running 6 For a Happy amp Healthy Life SAFETY INSTRUCTIONS The following instructions are for ensuring the user s safety and to prevent any physical injury or material damage Please read carefully and follow all instructions A There are two sectio
2. amp Healthy Life WARRANTY Applicable to first retail purchaser only AIRREX DEHUMIDIFIER give more reliable performance comfort and durability the more they are used They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing In the unlikely event you have any problems please contact your dealer or distributor If the problem is as a result of a production fault or failure repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions 1 The warranty period is 12 months from the date of first purchase 2 If the problem has been caused by customer error or misuse abuse or damage then all repairs will be charged for 3 This warranty applies to your country 4 Proof and date of purchase must be supplied 5 Please complete the details below and keep this warranty in a safe place 6 All transport charges back to the dealer are at the customers cost Keep all original packaging to facilitate return Return to customer will be at dealers cost if genuine warranty claim DESCRIPTION DEHUMIDIFIER MODEL ADH 1000 PRODUCT meme Woes o e Name CUSTOMER E DETAILS Address Telephone 8 AIRREX For a Happy amp Healthy Life e Designs and specifications of products are subject to change without prior notice for the improvement of products
3. being supervised not to be play with appliance IEC 60335 1 A2 oO For a Happy amp Healthy Life DESCRIPTION DIGITAL CONTROLLER ir AIR INLET AMBIENT AIR INTAKE EVAPORATOR FILTER CONDENSED WATER OUTLET DURING DEHUMIDIFYING CASTER REAR 10 CASTER FRONT LOCKABLE BACK HANDLE CONDENSER AIR OUTLET CONDENSER GRILLE PUMP BUTTON POWER CORD o For a Happy amp Healthy Life DESCRIPTION O Quiet Operation D Error Defrost Water full a QUIET OPERATION OFF TIMER 2 Power Use to power On Off OVA Raises or lowers setting humidity and sleep off time Q Fan Intensity Controls fan speed high medium low F3 F2 F1 2 Quiet Operation Set fan speed slower than Low FL the LED is on Off Timer To set the length of time once turned on that you wish the dehumidifier to run for You can set 024 hours Time intervals are 30mins up to 10 hours and then 1 hour between 10 and 24 hours Defrost When the temperature of the evaporator is below 4 C the defrost valve operate and Defrost led is on Comp When the compressor is operating the LED is On Error Error signal E1 High Pressure E2 Low Pressure E3 Defrost Sensor HU Humidity Sensor O Water Full Red light indicates Tank Full The compressor will shut off automatically Empty tank and check if condensate wafer pump operat
4. e well Display Display current humidity setting humidity and sleep time in case of setting them When the user set the sleep timer hr will be turned on A 6 For a Happy amp Healthy Life OPERATION O Quiet Operatio O Error Current Humidity O Defrost O Water full a Y Comp l em Li QUIET OPERATION OFF TIMER E hr Setting Humidity Li Lt 1 START BY PRESSING THE POWER BUTTON Dehumidifier will start up automatically To STOP the unit press the POWER button once again 2 To change fan speed press the Fan button F3 High F2 Medium F1 Low o For a Happy amp Healthy Life OPERATION Current Humidity CEM O Setting Humidity SS gt 7 Du Setting Humidity 45 ILI Setting Humidity gt ju 4 P J Li N 1 When power is ON the setting humidity is displayed Default of setting humidity is 60 2 When you push either v or 4 button the setting humidity is changed 3 The display showing the setting humidity will blink 3 times 4 Limits of Setting humidity Current Humidity Setting Humidity 0 99 30 80 Dehumidifier operates when current humidity is more than setting humidity Dehumidifying stops when current humidity is less than setting humidity A 6 For a Happy amp Healthy Life OPERATION Sett
5. ing Humidity Em 1 When dehumidifier is operating press the Off Timer Um Li button and set the length of time you want by pressing A or V Each time you press the button you will increase the time to off period by 30mins up to 10 hours and 1 hour thereafter up to 24 hours ne The display will show 5 for 30min and 1 for an hour Setting Humidity e g One and a half hours will show 1 5 Sr Ltd 2 When you have finished setting the time period the Off Timer lamp will be on which indicates Setting Humidity hr dehumidifier is in sleep Off Timer mode mii EL OFF TIMER LAMP IS ON E humidi hr ici DE 3 If you press the Off Timer button during its operation o y the remaining time will be shown i 1 rT EL Lt AFTER 1hr E 4 To CANCEL timing press Off Timer button for ONE 2 second It will then switch the timer off automatically This function enables you to set the length of time you want the dehumidifier to operate You can set the time period from 30min to 24 hours in 30min and 1 hour increments o For a Happy amp Healthy Life OPERATION 1 WATER FULL Display shows FU Current Humidity o water Full Edi When the water container is full FU is displayed Lf and the LED Water Full light will be on Setting Humidity 2 HIGH PRESSURE Current Humidity PRE a a El is displayed and the Error LED will be on when the pre
6. mage by damp humidity and dust o For a Happy amp Healthy Life TROUBLE SHOOTING TROUBL REMEDY Power plug correctly connected e Connect plug correctly POWER button OFF e Press POWER button to ON Blown fuse in electric panel e Replace fuse 5A Fuse blown e Exchange fuse in board 1A Breaker on switch board e Check load capacity and reset tripped e Filter blocked with dust e Clean Filter POOR e Dust in heat exchanger e Clean heat exchanger DEHUMIDIFYING e Obstacle against inlet side e Remove and allow 50cm clearance e Ambient temp too high e Use only below 35 C over 35 C MANUAL PUMPING If you move Dehumidifiers to another place it is necessary to empty condensate water in tank so press pump button to empty water in tank Pr A 18 For a Happy amp Healthy Life SPECIFICATIONS l iea Maximum 120 Capacity iter day Nominal 80 20 C 70 weer fe 0 6 CE TT Air Filter Vinyl Chloride Mesh Catridge Safety Device gt High pressure switch gt Low pressure switch gt 3 min delay timer gt Fan motor protection gt Automatic full tank shut off Thermostat protector for compressor mm er 5 Fuse in power box in Machine body 250V 5A o For a Happy amp Healthy Life o For a Happy amp Healthy Life A 6 For a Happy amp Healthy Life o For a Happy amp Healthy Life A 6 For a Happy
7. ns to these instructions WARNING and CAUTION The following symbols are for your guidance X You must NOT v You MUST Use a 230V 50Hz 1 Phase power supply only Wrong supply may cause a fire and or shock hazard Securely plug into an earthed supply Unless earthed may cause electric shock Do not use a damaged power cable plug or socket Short fire or shock hazard Do not remove plug by pulling cable or with wet hands Risk of fire and electric shock Before cleaning remove plug from socket Otherwise risk of electric shock Do not use an extension lead unless of the approved type Risk of fire and or electric shock Ensure mains plug is clean and securely plugged in Otherwise it may short causing smoke and fire Do not kink or sharply bend the power cable nor put any weight on it The insulation may be damaged causing fire and or electric shock Do not turn off by removing power plug Always turn off at control panel first Risk of electric shock and or malfunction Do not use this dehumidifier on unstable or inclined surfaces Always use on solid flat floor Risk of falling causing injury fire or malfunction O Keep this manual in a visible location near the dehumidifier for easy reference o For a Happy amp Healthy Life SAFETY NOTICE Do not place dehumidifier on uneven un
8. ssure of the compressor is too high Lo and the high pressure switch is open Current Humidity 3 LOW PRESSURE E a E2 is displayed and the Error LED will be on when the pressure of the compressor is too low 4 DEFROST SENSOR PROBLEM Current Humidity E z If the thermistor for defrost is short circuited a or cut E3 is displayed and the Error LED will be on Current Humidity 5 HUMIDITY SENSOR PROBLEM Ley yeu If the Humidity Sensor is short circuited or cut Hu is displayed and the Error LED will be on The machine s safety devices will automatically signal any problems via the display window on the control panel The information below shows how to read these signals A 6 For a Happy amp Healthy Life OPERATION 1 IF you press the off timer button for 5 seconds it operates continuously 2 Setting value is Setting Humidity changed to circle type SS Livi hr Setting Humidity 3 To cancel this mode press off timer button for 5 second A 6 For a Happy amp Healthy Life E CLEANING AND MAINTENANCE 1 To remove filters open the front case and pull towards you 2 2 Clean the filters with water or compressed air 3 Clean heat exchanger unit with a vacuum cleaner or compressed air 1 Turn OFF at control panel remove plug from socket Coil and store cable neatly 2 Keep machine suitably covered to prevent da
9. stable or inclined surface This could cause malfunction When storing the dehumidifier ensure that it is kept in a dry cool place To prevent corrosion and malfunction If not being used for some time or if lightening is present always unplug from power To prevent risk of electric shock short circuit or fire Do not spray water on to the dehumidifier nor use solvents such as benzene thinner or alcohol for cleaning There is a risk of electric shock and or short circuit the power cable is damaged this must be replaced by a fully qualified electrician To avoid danger of electric shock short circuit or fire GENERAL ADVICE BEFORE USE Ensure the safety of the location in which dehumidifier is to be used Ensure the floor or ground is smooth and sound Ensure you allow at least 1m air space all around the dehumidifier When in position LOCK the casters to prevent rolling Never use the dehumidifier at more than 2 incline FOR MAXIMUM EFFICIENCY Ensure correct electricity supply The proper electricity is 230V 50Hz It will be applied and adjusted as per customer s request You must supply power as per it s requirement only once it is adjusted Appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction IEC 60335 1 A2 Children