1. sve i PF Series Installation amp Operating Manual PM13500PF PM13500UF UV Option Warning Never leave children unsupervised around water Table of Contents LIMITED WARRANTY ADG Global Supply Pty Ltd will repair or replace any unit found to be defective within two years of original purchase Cutting 1 Safety guidelines or altering cord removing or defacing product labels voids any warranty consideration For warranty repair return only the part 2 Product Specification that is defective to your local dealer Please include a dated proof of purchase Damages or injuries resulting from negligence 3 Exploded Drawing shipping handling improper installation maintenance or misuse of the product are not covered by warranty This warranty 4 Installation gives you specific legal rights which vary from state to state 5 Open the lid To validate this warranty keep your proof of purchase copy of sales receipt 6 Filter Media Placement WARRANTY Ts Inlet Outlet Installation 8 Start up method 9 Backwash Method 10 UV light Usage and Replacement PM13500PUF Head Office Australia National Customer Service 1300 132 302 PO Box 2012 Malaga WA 6944 17 Oxleigh Drive Malaga WA 6090 www universalpumps com au a Phone 61 8 9249 7599 Fax 61 8 9249 7699 a moving water PHONE 1300 132 302 Universal Pumps Range by ADG Global Supply Pty Ltd Universal Pumps Range by ADG Global Supply Perth Adelaide Melbourn
2. e Sydney Brisbane 1 SAFETY GUIDELINES 3 DIAGRAM OF PARTS EXPLODED DRAWING Foremost we deeply appreciate your purchase of PondMate PF Series pressurised filter For the correct and safe usage of this product please read thoroughly and understand fully this user s manual before operating the pressurised filter Please understand our company will not be responsible for any disease wither or death of fish water plants and other organisms caused by incidents attributed to incorrect operating method or inadequate maintenance In effort to improve product quality we will make necessary modifications to our existing model without prior notification CAUTION 1 Please check immediately after purchase for damage or missing parts 2 Please install the unit in stable position above water level or bury the filter canister in the ground 3 Best used in ponds with volume capacity of 13 500L 3 600Gal or less 4 Before operation please check again for proper connection After initial start please observe a while to make sure no leakage or unusual working condition This product is limited to artificial pond only please do not use for any other purposes Install the unit on levelled surface and never place it horizontally or place object on top or encircle it with something Electric cord has been treated for waterproofing please use with caution since it won t be repair able or replaceable Inappropriate use of filter materials will result in r
3. educed flow therefore please use filter materials provided by our company Please use adequate length of connecting tube Overly long length will lead to tube bending which inhabits flow Please do not connect two filter units together or apply one to multiple ponds Regular cleaning of every part and replacing of gasket and sealant will reduce breakage and increase product life The maximum head height Qmax of the selected pump can t be over of 5 0m Reminder Before operating hand please unplug the power with dry hands Use this filter within the specified voltage rating parameter Keep the power cord plug and receptacle clean and dry Prevent children from operating the unit Do not use near flammable material 2 PRODUCT SPECIFICATION Pond Capacity Max Dimensions Inlet Outlet mm Flow Recommended Pump Qmax UV Lamp Dimensions Power Outlet Waste Litres Litres Inlet Tube Tube Outlet mm 25 25 32 32 435x370x642 PM13500PF PM13500PUF 25 25 UV Option 32 32 435x370x642 Handle Transparent Cover Top Lid Assembly Outlet Gasket Inlet Outlet Assembly UV Light EPF 13500U Glass Sleeve Assembly EPF 13500U Metal Hoop Guiding Water Tube M Bucket Gasket Black Filter Sponge Blue Filter Sponge Blue Filter Sponge Base Plate Assembly 4 Bio Ball 46 Bucket 4 Ball Valve Assembly 48 Pressure Releaser Gasket 49 Pressure Re
4. hten the inlet outlet assembly Wrap the waste oulet Ball Valve thread with sealing tape assembly o mm Gasket Inlet Outlet assembly A The hose connecting to the inlet port marked PUMP needs to have the other end connected to the water pump The hose connecting to the outlet port marked WORK needs to have the other end connected to the pond so that the filtered water can return to the pond waterfall or fountain The hose connecting to the ball valve assembly needs to have the other end connected to a sump or a sprayer for watering the plants Note Ifthe user will only use the largest diameter on the Inlet Outlet assembly for hose connection then the two smaller diameter sections can be sawed off for guaranteed flow and increased filter efficiency 5 START UP 5 1 Position the ball valve in closed condition CH Closed Condition 5 2 Make sure the water pump is submerged in pond with great connection Ensure that the hose connection is not bending 5 3 Rotate the handle so that the arrow will point to WORK Top Lid Top Lid eo ad Rotating Assembly Rotating Assembly Two Arrows Must Line Up Make sure the power plug is dry before plugging into receptacle that is positioned in a safe position without being rained on After start up make sure all parts are operating properly without leakage For PM13500PUF open the transparent cover to turn on the UV light observe whe
5. leaser Knob 4 INSTALLATION 4 1 Installation Position 1 Must be installed above water level 2 Must keep bucket levelled not easy to tilt over 3 For ease of operation and space saving the product is recommended to be buried in the ground Recommended Burrial Level 10cm Water Level 4 2 Opening of lid 1 Rotate to open the knob of the pressure releaser 2 Remove the metal hoop between the top cover and the bucket 3 Lift up the top cover by grabbing the inlet and waste outlet tube eer 4 3 Filter media placement 1 Please follow the placement order shown below to ensure best filtering Black filter p 1 Blue Filter Sponge Blue filter as Fir Sponge Blue filter Baso Plate Assorbly Base plate Assembly Bio Ball Bio balls 60pcs 2 After completing above step please close the top cover assembly and tighten with metal hoop Please have adult handle the mental hoop to prevent accidental nipping of the hand 4 INSTALLATION CONTINUED 4 4 Inlet Outlet Tube Installation 1 Included Assembly parts o cit Gasket Inlet Outlet Assembly Sealing Tape Ball Valve Assembly 2 Required Purchase parts Inlet Outlet 32mm 1 1 4 Hose or 26mm 017 Hose or 40mmid 1 2 Hose 20mm 03 4 Hose Waste Outlet Wrap the waste outlet thread with sealing tape then screw in the waste outlet assembly with ball valve Tighten to prevent leakage Place the gasket onto inlet outlet then screw on to tig
6. off the transparent cover A If the LED indicator does not light up after pressing then UV light might need replacing B The working hour of the UV light can be determined by pond capacity amp breeding type un 7 2 UV Light Bulb Replacement ee A Open up top lid assembly take out the middle Guiding Tube water guiding tube assembly B Gently pull out the quarts glass sleeve B C n C Pull out the failed UV bulb and then take off the bulb support frame Replace with a new bulb by attaching the support frame insert it into the receptacle and then slide the quarts glass sleeve back on Quartz Glass Sleeve Bulb Support Frame e t UV Light Bulb p
7. ther LED lights up which would indicate if UV light is functioning 6 BACK WASH 6 1 When the red rubber inside the annunciator rises to viewable level through the transparent cover there is too much waste accumulated inside the bucket and backwash is needed Turn off the water pump make sure UV light is in off position for PM13500PUF Rotate the handle 120 degrees to the CLEAN position 120 Arrows Line up Top Lid oe Rotatable Assembly Rotatable Assembly 6 BACK WASH CONTINUED 6 4 Rotate the handle 120 degrees to the CLEAN position C Open Condition 6 5 Make sure one end of the hose is connected to the ball valve and the other end connected to sump then turn on the water pump to begin backwash After water coming out of the waste outlet turns clean shut off the water pump Rotate the handle back to Work position and turn on the water pump back on to begin filtering process Since the waste will not be completely cleaned during the backwash it is recommended to take out the filter media for thorough cleaning after performing three times of backwash 7 UV LIGHT USAGE amp REPLACEMENT 7 1 UV Light Usage A Open up the transparent cover on the top lid B Turn on by pressing downward if the LED indicator lights up then the UV Light is working C Turn off by pressing o downward if the LED indicator light is off then the UV Light has stopped working D Close