1. Table 2 Memory modules population With a dual channel configuration identical memory modules are to be used for the individual population possibilities U41600 J Z156 1 76 Options Guide 21 Installing Removing Main Memory Main Memory 6 2 Installing Removing Main Memory Remove the side cover and the system fan as described in chapter Prepa ration on page 13 gt Unpack the memory module 1 Figure 10 Installing a memory module gt Push the holder on each side of the memory slot outward 1 gt Insert the memory module in the slot 2 while folding the side holders up until the memory module engages 3 Close the server connect it to the mains and switch it ON as described in chapter Completion on page 37 and following Proceed in the reverse order for removal 22 Options Guide U41600 J Z156 1 76 7 Accessible Drives CAUTION Refer to the safety notes in chapter Safety on page 7 and following Two free 5 25 inch bays are available for additional accessible drives CD ROM DVD ROM CD RW DVD DVD R RW CD RW or tape backup drive If a backup drive tape is to be installed a PCI SCSI controller is needed The 5 25 inch bays can be equipped as follows with accessible drives Figure 11 Accessible drives overview of the installation sequence pos slot drive 1 1 second tape 2 first tape 3 firs
2. Insert the system board into the housing by holding it at a slight angle and sliding the connectors into the connector panel Figure 21 Adjusting the system board B gt Carefully place the system board into the housing Make sure there are no cables jammed under the system board gt Adjustthe system board If necessary adjust the position of the system board with a gentle twisting motion When the system board is in the right position the centering rings engage in the holes indicated gt Fasten the system board with the 9 screws gt Reconnect all cables to the system board see cabling in the appendix and D2020 sticker Econel 200 Service Supplement 31 Replacing the System Board Replacement Routines gt Mount the processor s the heat sink s and the fan s and the memory modules onto the new system board Insert all controller in the relevant slots and reconnect the cables for description see Options Guide gt Re install the system fan and return the server to its original installation location gt Close the server for a detailed description see the Options Guide and reconnect the power plug Connect all external cables CAUTION After installing the new system board it is necessary to update the BIOS to ensure proper operation for description see the BIOS Manual 32 Service Supplement Econel 200 5 Appendix 5 1 Cabling The following table gives you
3. General Purposes Replacement Routines 4 1 2 Removing Mounting the Front Panel Remove the front panel when making the following replacements Replacing the operating panel cable Replacing the floppy disk drive Replacing the CD DVD drive Replacing the front fan Replacing the intrusion detection switch D You will find a detailed description in the Econel 200 Options Guide gt Remove the left side cover as described in section Removing Mounting the Side Cover on page 13 gt Detach the three unlocking levers on the side and fold out the front panel gt Remove the front panel carefully Proceed in the reverse order for mounting 4 1 3 Removing Mounting the System Fan Remove the system fan when making the following replacements Replacing the power supply unit Replacing memory modules Replacing the system board D You will find a detailed description in the Econel 200 Options Guide gt Remove the left side cover as described in section Removing Mounting the Side Cover on page 13 Disconnect the fan cable from the rear fan port on the system board see D2020 sticker gt Detach the unlocking lever and remove the fan Proceed in the reverse order for mounting 14 Service Supplement Econel 200 Replacement Routines Replacing the Operating Panel Cable 4 2 Replacing the Operating Panel Cable gt Remove the left side cover and the front panel a
4. Notational conventions U41600 J Z156 1 76 Options Guide 3 2 Procedure CAUTION The actions described in this manual should only be performed by techni cians service personnel or technical specialists Equipment repairs should only be performed by qualified staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock energy hazards fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability At first please take notice of chapter Safety on page 7 and following Make sure all necessary manuals see Additional server documentation on page 1 are available possibly print of the PDF files You will definitely need the Operating Manual for the server and the Technical Manual for the system board Shut down the server correctly switch it OFF pull out the power plug and open the server as described in the chapter Preparation on page 13 and following Expand or upgrade your server as described in the relevant chapter Close the server connect it to the mains and switch it ON as described in chapter Completion on page 37 and following Start the operating system and if necessary configure it as required see Operating Manual U41600 J Z156 1 76 Options Guide 5
5. 3 Safety il The following safety notes are also provided in the Safety manual This device complies with the relevant safety regulations for information technology If you have any questions about where you can set up the device contact your sales outlet or our customer service team CAUTION The actions described in this manual should only be performed by techni cians service personnel or technical specialists Any repairs on the device must be performed by authorized technically qualified personnel Any unauthorized openings and improper repairs could expose the user to risks electric shock energy hazards fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Before operating the device CAUTION e During installation and before operating the device observe the instructions on environmental conditions for your device e Ifthe device is brought in from a cold environment condensation may form both inside and on the outside of the machine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed e Transport the device in its original packaging or in other suitable packaging which will protect it against shock or impact U41600 J Z156 1 76 Options Guid
6. 4 1 1 Removing Mounting the Side Cover 13 4 1 2 Removing Mounting the Front Panel 14 4 1 3 Removing Mounting the System Fan 14 4 2 Replacing the Operating Panel Cable 15 4 3 Replacing the Temperature Sensor 17 4 4 Replacing the Floppy Disk Drive 17 4 5 Replacing the CD DVD Drive 19 4 6 Replacing the Power Supply Unit 21 4 7 Replacing the Front Fan o 23 4 8 Replacing the Intrusion Detection Switch 28 4 9 Replacing the ID Combo Print 29 4 10 Replacing the System Board 30 5 Appendix 2 4 n4 248 eo Reh bbe erg S dae os 33 5 1 Cabling 4 ata er E ee AA Sis 33 Index at 235 E RA e Mk EE 37 Econel 200 Service Supplement 1 Introduction The PRIMERGY Econel 200 server is an Intel based server for workgroups and small networks The server is suitable for use as a file server and also as an application information or Internet server 1 1 Overview of the Documentation Concept and target group of this manual This Service Supplement completes the information given in the Operating Manual the Options Guide and the Technical Manual of the system board The actions described in this manual should only be performed by service personnel Service CD Service partners of Fujitsu Siemens can order a Service CD On the CD the following manuals
7. Installing Removing SATA Hard Disk Drive SATA Hard Disk Drives 8 1 1 Cabling SATA Hard Disk Drives Two SATA hard disk drives gt Connect the power cable connector P16 to the relevant power connector of the second SATA drive You should read the accompanying documentation supplied with the drive beforehand gt Connect the SATA cable T26139 Y3928 V101 to the SATA interface of the second SATA drive the free cable is already connected to the system board and fixed with cable clips at the housing bottom see also figure 17 to the power supply Figure 17 Two SATA drives cabling 30 Options Guide U41600 J Z156 1 76 SATA Hard Disk Drives Installing Removing SATA Hard Disk Drive Four SATA hard disk drives If more than two SATA hard disk drives are installed an additional PCI SATA controller is necessary The four SATA hard disk drives will be connected to the SATA interfaces Port 1 Port 4 of the controller see figure 18 on page 32 gt Install the SATA controller in the lowest PCI slot see chapter Controllers in PCI Slots on page 33 gt Connect the power cable connector P17 and P18 to the relevant power connector of the third and fourth SATA drive You should read the accompa nying documentation supplied with the drive beforehand gt Connect the two SATA cables T26139 Y3928 V101 delivered with the controller to the SATA
8. fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
9. in section General Purposes on page 13 Release the sensor from the cable clamp and remove the cable The temper ature sensor is placed under the floppy disk drive see figure 2 on page 15 gt Connect the cable to the new sensor orient the sensor towards the front of the server and secure it with the cable clamp Close the server for a detailed description see the Options Guide and reconnect the power plug 4 4 Replacing the Floppy Disk Drive gt Remove the left side cover and the front panel as described in section General Purposes on page 13 gt Disconnect the power supply cable connector P11 from the floppy disk drive Disconnect the data cable T26139 Y1248 V201 from the floppy disk drive Econel 200 Service Supplement 17 Replacing the Floppy Disk Drive Replacement Routines Figure 4 Removing the slide in unit with floppy disk drive gt Remove the two screws 1 and pull the slide in unit with the floppy disk drive out of the location 2 Figure 5 Removing the floppy disk drive gt Remove two screws on both sides 1 lift the floppy disk drive in the direction of the arrow 2 and remove it from the slide in unit Insert the new floppy disk drive into the slide in unit and fasten it with two screws on each side 18 Service Supplement Econel 200 Replacement Routines Replacing the CD DVD Drive gt Insert the slide in unit into the h
10. is damaged during the installation or replacement of system expansions e You may only set those resolutions and refresh rates specified in the Technical data section of the monitor description Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service centre U41600 J Z156 1 76 Options Guide 9 Safety Batteries CAUTION Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the technical manual for the system board under Related Publications on page 41 Do not throw batteries into the trash can They must be disposed of in accordance with local regulations concerning special waste The battery must be disposed of in accordance with local regulations concerning special waste Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board see Related Publications on page 41 All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol ofthe heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead 10 Options Guide U41600 J Z156 1 76 Safety Notes on handling CDs DVDs and CD DVD drives CAUTION e Use only CDs DVDs in prope
11. is printed on paper treated with chlorine free bleach Contents 1 Introduction x o 2 ae ee PR ee a a aa 1 1 1 Overview of the Documentation 1 1 2 Expansions and Conversions 2 1 3 Notational Conventions aooaa 3 2 Procedure 2 s a a 20 0 0 a Rae S ab Q mus 5 3 Safely rr nt EE x en Be A Dh 7 4 Preparation EN waw a Cus g os e Bene 13 4 1 Opening the Housing 13 4 2 Removing the Front Panel 15 4 3 Removing the System Fan 2 2 2 nn 16 5 Prfocess rs E EE W S S A 17 5 1 Mounting Removing the Processor 17 5 2 Mounting Removing the Heat Sink 19 5 3 Mounting Removing the Fan 20 6 Main Memory 21 6 1 Slot Population Rules e 21 6 2 Installing Removing Main Memory 22 7 Accessible Drives 23 7 1 Installing the Tape Drive o s r s 24 7 1 1 Connecting the Drives 26 8 SATA Hard Disk Drives 27 8 1 Installing Removing SATA Hard Disk Drive 27 8 1 1 Cabling SATA Hard Disk Drives 30 9 Controllers in PCI Slots 33 9 1 Installing the PCI Controller e 33 10 Co mpleti n i 42s Ae is re aan 37 10 1 Mounting the System Fan 37 10 2 Mounting the Front Cover 38 10 3 Closing the Housing o 39 Related Publications 41 O AN 43 U
12. mechanical properties of a CD DVD and cause imbalance Damaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain conditions sharp edged pieces of broken CDs DVDs can penetrate the cover of the drive damage to the device and be thrown out of the device danger of injury particularly on uncovered body parts such as the face or neck You protect the CD DVD drive and prevent mechanical damage as well as premature wearing of the CDs DVDs by observing the following suggestions Only insert the CDs DVDs in the drive when needed and remove them after use Store the CDs DVDs in suitable sleeves Protect the CDs DVDs from exposure to heat and direct sunlight Service Supplement Econel 200 Safety Note about the laser The CD DVD drive is classified for laser class 1 according to IEC 60825 1 CAUTION The CD DVD drive contains a laser diode LED Sometimes the LED produces a stronger laser beam than laser class 1 Direct view into the laser beam is dangerous Never remove parts of the CD DVD drive assembly Modules with electrostatic sensitive components Systems and components that might be damaged by electrostatic discharge ESD are marked with the following label Ale When you handle components fitted with ESDs you must observe the following points under all circumstances Figure 1 ESD label e Remove the power plug from the power socket before inserting
13. on the rear side of the server U41600 J Z156 1 76 Options Guide 13 Opening the Housing Preparation Figure 3 Removing the side cover gt Slide the side cover approximately 2 cm a in the direction of the arrow 1 until the stop gt Remove the side cover 2 14 Options Guide U41600 J Z156 1 76 Preparation Removing the Front Panel 4 2 Removing the Front Panel For the installation of additional accessible drives the front panel is to be removed Figure 4 Removing the front panel gt Remove the side cover as described in section Opening the Housing on page 13 gt Detach the three unlocking levers 1 and open the front panel 2 gt Remove the front panel carefully U41600 J Z156 1 76 Options Guide 15 Removing the System Fan Preparation 4 3 Removing the System Fan For the installation of additional memory modules the system fan is to be removed Figure 5 Removing the system fan gt Remove the side cover as described in section Opening the Housing on page 13 gt Remove the fan cable from the connector rear fan on the system board see sticker D2020 gt Detach the locking lever 1 and remove the system fan 2 16 Options Guide U41600 J Z156 1 76 5 Processors CAUTION Refer to the safety notes in chapter Safety on page 7 and following CAUTION You may only use processors ofthe same
14. the grid as shown in figure 14 Pay attention to the direction of rotation and the airflow Fasten the fan with the four body bound rivets 1 Econel 200 Service Supplement 25 Replacing the Front Fan Replacement Routines Figure 15 Securing the front fan to the grid Press one bolt into each rivet to secure the fan to the grid Figure 16 Mounting the front fan gt Thread the cable through the opening 1 and pull it inside the housing 26 Service Supplement Econel 200 Replacement Routines Replacing the Front Fan Figure 17 Mounting the front fan gt Place the assembled fan at a slight angle into the appropriate opening 1 push it into the direction of the arrow 2 and secure it with the green rivet gt Attach the fan cable to the adapter cable see position 1 figure 11 on page 24 and thread the cables under the hard disk drive cage Route the adapter cable through the cable clamp see position 2 figure 10 on page 23 and reattach the adapter cable to the connector front fan on the system board see D2020 sticker gt Close the server for a detailed description see the Options Guide and reconnect the power plug Econel 200 Service Supplement 27 Replacing the Intrusion Detection Switch Replacement Routines 4 8 Replacing the Intrusion Detection Switch The intrusion detection switch monitors the removing of the left side cov
15. type on the system board The second processor must have the same type and clock rate as the first Use a suitable multiprocessor operating system if dual operation is required The upgrade kit includes one processor one heat sink and one processor fan 5 1 Mounting Removing the Processor gt Remove the side cover as described in section Opening the Housing on page 13 Take out the processor from its protective wrapper CAUTION Processors are components which are extremely sensitive to electro static discharges and must be handled with caution After taking a processor out of its protective wrapper set it on an insulated antistatic surface with the smooth side down Never slide a processor over a surface U41600 J Z156 1 76 Options Guide 17 Mounting Removing the Processor Processors s Figure 6 Installing the processor gt Release the socket lifter by pressing it sideways and pull it upward until it stops 1 Position the new processor over the socket and press it carefully into the socket 2 CAUTION The processor can only be installed in one particular direction Pay attention to the location mark on one of the corners Do not use force to press it into the socket to avoid damaging the pins or the processor Lock the processor into place in the socket by placing the socket lever in its original position Mount the heat sink and the processor fan as described in the next s
16. until it engages U41600 J Z156 1 76 Options Guide 39 Closing the Housing Completion Figure 24 Fastening the side cover gt Press the side cover onto the housing and tighten the two knurled screws 1 gt Return the server to its original installation location gt Reconnect any disconnected cables gt Connect the power plug to the grounded power outlet switch ON the power supply unit press the main power switch and press the ON OFF button 40 Options Guide U41600 J Z156 1 76 Related Publications PRIMERGY manuals are available as PDF files on the ServerBooks CD The ServerBooks CD is part of the ServerView Suite delivered with each server system The actual version of the necessary manuals can be downloaded free of charge from the Internet The overview page showing the online documentation availble in the Internet can be fount via the URL http manuals fujitsu siemens com choose intel based servers 1 Safety 2 Warranty 3 PRIMERGY ServerView Suite ServerStart 4 PRIMERGY Econel 200 Operating Manual 5 System board D2020 Technical Manual 6 D2020 Setup Utility Description 7 FastTrak S150 TX4 Quick Start Guide 8 FastTrak S150 TX4 User Manual 9 Configurator For partners and distributors only http extranet fujitsu siemens com cafe products primergy U41600 J Z156 1 76 Options Guide 41 Index A accessible drives 2 23 C control
17. 41600 J Z156 1 76 Options Guide 1 Introduction The PRIMERGY Econel 200 server is an Intel based server for workgroups and small networks The server is suitable for use as a file server and also as an application information or Internet server 1 1 Overview of the Documentation PRIMERGY manuals are available in PDF format on the ServerBooks CD The ServerBooks CD is part of the ServerView Suite delivered with each server system The PDF files for the manuals can also be downloaded free of charge from the Internet at ht1p manuals fujitsu siemens com you will find an overview page with the online documentation available on the Internet You can go to the PRIMERGY Server documentation by clicking on intel based Servers Concept and target group of this manual This Options Guide describes how to expand and upgrade the server The actions described in this manual should only be performed by technicians service personnel or technical specialists Additional server documentation To the PRIMERGY Econel 200 documentation set belong the following additional manuals Safety manual print version delivered together with the system PDF file available on the ServerBooks CD Warranty manual print version delivered together with the system PDF file available on the ServerBooks CD Operating Manual for the PRIMERGY Econel 200 PDF file available on the ServerBooks CD Technical Manual for the sy
18. PRIMERGY Econel 200 Server System Service Supplement Edition February 2005 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright O 2004 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers This manual is printed on paper treated with chlorine free bleach Contents 1 Introduction 00 4425 er do Dana Qu 1 1 1 Overview of the Documentation 1 1 2 Notational Conventions 3 2 Procedure sr sue s v s s a a e A 5 3 Salty A acim Be oe gl SL ne Ener dr med 7 4 Replacement Routines 13 4 1 General Purposes 13
19. an overview of the cables Part number Name T26139 Y3848 V101 Operating panel cable temperature sensor T26139 Y3718 V701 ID Combo T26139 Y3662 V304 IDE cable T26139 Y1248 V201 Floppy disk drive T26139 Y3576 V209 SCSI cable T26139 Y3609 V102 Front fan T26139 Y3736 V201 Intrusion detection switch T26139 Y3928 V101 SATA cable T26139 Y2361 V102 HDLED cable T26139 Y3646 V1 System fan Econel 200 Service Supplement 33 Appendix BELIZL ed age eed oqwogy Ql LOZA BYZLA q3 301 x e POSA Z99CA z Vivs aaa ao S AS Ja va S gt pu b 7 SS Es ada a SL 3 9 Abd LOLN BZBEA s z Auq z SL LOLA 8Z6EA u gt nud ESTIU HE Sid qqH vlvS N o de SO0ZA 9LGEA gt o ISOS e 3 8d SS ade s ISIS ld S 0 gt ic SS vw SSS jeued do LOLA 8P6EA Cabling Josuas duet PSU Figure 22 Basic cabling with two SATA hard disk drives Econel 200 Service Supplement 34 Cabling BELIZL xu 1d lqeO eyegq _ oquoy Al LOZACHPCL A UO Sd VOEA Z99EA VLVS dAq d9 E J MOd gal S ces vd
20. are available in PDF format Safety manual Operating Manual for PRIMERGY Econel 200 Technical Manual for the system board D2020 Options Guide for PRIMERGY Econel 200 Service Supplement PRIMERGY Econel 200 D2020 Setup Utility manual Econel 200 Service Supplement 1 Overview of the Documentation Introduction Information procedure Manual Detailed safety notes Safety Features and technical data of the server Installation and operation among other things External ports on the server Operation Configuration of the server Troubleshooting Information about the system board Features of the system board Pin assignment of the connectors Jumper settings LED indicators Replacing the battery Operating Manual Technical Manual Extensions and upgrades For some components only the installation il routine is described in the Options Guide Removing these components proceed in reverse order Extending replacing the main memory Replacing processor heat sink fan Installing accessible drives Installing SATA hard disk drives Installing controllers in PCI slots Options Guide Replacement routines Replacing the operating panel cable Replacing the temperature sensor Replacing the ID Combo print Replacing the floppy disk drive Replacing the CD DVD drive Replacing the power suppl
21. ck rails are locked in position Proceed in the reverse order for removal Connect the cables to the drive as described in the next section gt Close the server connect it to the mains and switch it ON as described in chapter Completion on page 37 and following U41600 J Z156 1 76 Options Guide 25 Installing the Tape Drive Accessible Drives 7 1 1 Connecting the Drives gt Connect the power cable connector P7 or P8 to the relevant power connector of the drive You should read the accompanying documentation supplied with the drive beforehand SCSI drives tape For the operation of additional backup drives tape a PCI SCSI controller is needed The PCI SCSI controller will be installed in one of the five PCI slots 1 5 see chapter Controllers in PCI Slots on page 33 gt Connectthe SCSI cable T26139 Y3576 V209 flat band cable delivered with the SCSI controller to the relevant SCSI interface of the tape drive You should read the accompanying documentation supplied with the drive and or the controller beforehand Connect the SCSI cable to the SCSI interface of the SCSI controller You should read the accompanying documentation supplied with the drive and or the controller beforehand 26 Options Guide U41600 J Z156 1 76 8 SATA Hard Disk Drives CAUTION Refer to the safety notes in chapter Safety on page 7 and following Up to three additional SATA hard disk drives can be install
22. e 7 Safety Installation and operation CAUTION The server automatically sets itselfto a voltage in the range of 100 V to 240 V Make sure that your local voltage is within this range This device has a specially approved power cable and must only be connected to a grounded insulated socket Ensure that the power socket on the device or the grounded wall outlet is freely accessible The power switch or the main power switch does not disconnect the device from the mains voltage To disconnect the line voltage completely remove the power plug from the grounded insulated socket CAUTION Always connect the device and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example the central processing unit is still running but the peripheral device e g storage subsystem has failed during a power outage Data cables must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Route the cables in such a way that they do not form a potential hazard make sure no one can trip over them and that they cannot be damaged When connecting up a device refer to the relevant notes in this man
23. ection CAUTION Never install a processor without heat sink and fan as otherwise the processor may overheat and fail causing the complete system board to fail Proceed in the reverse order for removal 18 Options Guide U41600 J Z156 1 76 Processors Mounting Removing the Heat Sink 5 2 Mounting Removing the Heat Sink I Hl A o Kl El EEN KH e K VV VVUC II I El Figure 7 Mounting the heat sink Remove the protective cover on the underside of the heat sink Place the heat sink onto the processor socket 1 CAUTION If you find an air flow arrow on the top of the heat sink place the heat sink in the way that the air flow arrow shows in direction of the server s rear side Fasten the heat sink by tightening the four screws in a crossover pattern 2 Proceed in the reverse order for removal U41600 J Z156 1 76 Options Guide 19 Mounting Removing the Fan Processors 5 3 Mounting Removing the Fan Figure 8 Mounting the processor fan Place the processor fan onto the lower edge of the heat sink a So the rubber buffers into the air duct are not damaged gt Tilt the fan in the direction of the arrow over the heat sink until the locking tab b engages in the ribs of the heat sink gt Connect the fan to the connector CPU fan 2 on the system board see the sticker on the side cover Close the server connect it
24. ed 8 1 Installing Removing SATA Hard Disk Drive gt Remove the side cover as described in section Opening the Housing on page 13 You find the necessary pre mounted EasyClick rails in the drive cage gt Remove the necessary EasyClick rails from the next free bay of the hard disk drive cage installation sequence from above downwara gt Unpack the new drive and make the desired settings You should read the accompanying documentation supplied with the drive beforehand U41600 J Z156 1 76 Options Guide 27 Installing Removing SATA Hard Disk Drive SATA Hard Disk Drives Interface Figure 15 Attaching the rails to the hard disk drive gt Press the EasyClick rails upper pin row into the mounting holes of the drive as shown in figure 15 Screws are not necessary the pins atthe rails engage into the mounting holes of the drive 28 Options Guide U41600 J Z156 1 76 SATA Hard Disk Drives Installing Removing SATA Hard Disk Drive Figure 16 Installing the hard disk drive gt Push the assembled drive with the rails into the free bay until the EasyClick rails are locked in position gt Attach the cables to the new drives described in the next section gt Close the server connect it to the mains and switch it ON as described in chapter Completion on page 37 and following Proceed in the reverse order for drives removal U41600 J Z156 1 76 Options Guide 29
25. er of the housing The intrusion detection switch is located behind the front fan gt Remove the left side cover as described in section General Purposes on page 13 gt Disconnect the cable from the system board connector Intrusion see D2020 sticker Figure 18 Removing the intrusion detection switch gt Loosen the two screws 1 and remove the intrusion detection switch from the holder CAUTION Make a note of the cable routing Place the new switch into the holder route the cable 2 under the hard disk drive cage and connect it to the Intrusion connector on the system board see D2020 sticker Close the server for a detailed description see the Options Guide and reconnect the power plug 28 Service Supplement Econel 200 Replacement Routines Replacing the ID Combo Board 4 9 Replacing the ID Combo Board The ID Combo board is located on the housing cover between the power supply unit and the operating panel module Remove the left side cover as described in section General Purposes on page 13 Figure 19 Removing the ID Combo board gt Remove the cable from the board 1 gt Loosen the screw 2 and remove the board gt Proceed in the reverse order to install the new board and reconnect the cable Close the server for a detailed description see the Options Guide and reconnect the power plug Econel 200 Service Su
26. escribed in section General Purposes on page 13 Figure 10 Disconnecting the cable The fan is connected to the system board via an adapter cable Unplug this adapter cable from the connector front fan 1 on the system board see D2020 sticker gt Release the adapter cable from the cable clamp 2 and slide it under the hard disk drive cage until the connector 3 will be visible on the other side ofthe cage see also next figure Econel 200 Service Supplement 23 Replacing the Front Fan Replacement Routines Figure 11 Disconnecting the adapter cable Disconnect the adapter cable from the fan cable 1 Make sure that the adapter cable does not slip back under the cage It serves as a pulling aid for routing the connecting cable of the new fan under the cage Figure 12 Removing the front fan Release the green body bound rivet 1 fold out the fan from the housing thread the cable through the opening 2 and remove the fan 24 Service Supplement Econel 200 Replacement Routines Replacing the Front Fan ES S body bound rivet Figure 13 Detaching the fan from the grid Push out the bolt from the body bound rivet 1 and pull out 2 the rivet gt Repeat the steps for the next three rivets direction of rotation l t airflow A Figure 14 Attaching the front fan to the grid gt Place the new fan onto
27. essary change the settings Please read the documentation for the installed PCI card Pay attention to the allocation of the PCI interrupts You find further infor mation in the Technical Manual for the system board D2020 PDF file available on the ServerBooks CD Proceed in the reverse order for removal U41600 J Z156 1 76 Options Guide 35 10 Completion CAUTION Refer to the safety notes in chapter Safety on page 7 and following 10 1 Mounting the System Fan Figure 21 Mounting the system fan Place the system fan into the relevant holes and press it in the direction of the arrow until it clicks audibly into place gt Connect the fan cable to the connector rear fan on the system board see sticker D2020 U41600 J Z156 1 76 Options Guide 37 Mounting the Front Cover Completion 10 2 Mounting the Front Cover Figure 22 Mounting the front cover Hook on the front cover 1 Swing the front panel in the direction of the arrow 2 until it engages 38 Options Guide U41600 J Z156 1 76 Completion Closing the Housing 10 3 Closing the Housing N E Figure 23 Mounting the side cover Place the side cover into the lower guide rail of the housing 1 Make sure that the cover is offset by approximately 2 cm a gt Hook the top edge of the cover on the housing and slide the side cover in the direction of the arrow 2
28. he left side cover as described in section General Purposes on page 13 gt Remove the system fan for a detailed description see the Options Guide gt Disconnect all power supply cables from the system board and from the drives see cabling in the appendix and release the cables from the cable clamps Jeo F A E Sp Figure 8 Removing the screws gt Remove the four fastening screws of the power supply unit at the rear of the server Econel 200 Service Supplement 21 Replacing the Power Supply Unit Replacement Routines Figure 9 Removing the power supply unit gt Remove the knurled screw 1 Remove the power supply unit by pushing it out from the holder 2 towards the front of the server gt Install the new power supply unit in the reverse order and secure it gt Connect all power supply cables to the system board see table and D2020 sticker and to the drives see cabling in the appendix Power supply cable System board connector D2020 connector P14 PC98 P13 PSU 12 V P1 PSU ATX gt Reinstall the system fan for a detailed description see the Options Guide Close the server for a detailed description see the Options Guide and reconnect the power plug 22 Service Supplement Econel 200 Replacement Routines Replacing the Front Fan 47 Replacing the Front Fan gt Remove the left side cover and the front panel as d
29. interface of the SATA drives see also figure 18 on page 32 gt Attach the HDLED cable T26139 Y2361 V102 delivered with the controller to the connector JP1 on the SA TA controller and the connector HDLED1 on the system board You should read the accompanying documentation supplied with the controller beforehand il Additional cables supplied with the SATA controller are not used U41600 J Z156 1 76 Options Guide 31 SATA Hard Disk Drives Installing Removing SATA Hard Disk Drive y Yod 49 j0 4U00 V 1VS IOd OW o bd f 49 0U09 v LVS 9d 94 0 Ld t VIVS t NYA N uod 1 llonuoo YLVS lode y TA ar VIVE Ken taai AJA DN z HOd J9 10 JUO9 Y 1YS GC 84 0 RQ zaya Hod 1 llonuo2 Y LYS ER aul Ri 0 D L Ada SC A ddns Jamod ay o 49 10 4409 V LVS 19d Figure 18 Four SATA drives cabling U41600 J Z156 1 76 Options Guide 32 9 Controllers in PCI Slots CAUTION Refer to the safety notes in chapter Safety on page 7 and following The system board offers five PCI slots for additional controllers The numbering of the slots takes place from down upward 2 6 9 1 Installing the PCI Controller gt Remove the side cover as described in section Opening the Housing on page 13 Figure 19 Removing the slot cover Swing the locking sw
30. is within this range e This device has a specially approved power cable and must only be connected to a grounded insulated socket e Ensure that the power socket on the device or the grounded wall outlet is freely accessible Econel 200 Service Supplement 7 Safety CAUTION The power switch or the main power switch does not disconnect the device from the mains voltage To disconnect the line voltage completely remove the power plug from the grounded insulated socket Always connect the device and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example the central processing unit is still running but the peripheral device e g an external drive has failed during a power outage Data cables must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Route the cables in such a way that they do not form a potential hazard make sure no one can trip over them and that they cannot be damaged When connecting up a device refer to the relevant notes in this manual Never connect or disconnect data transmission lines during a storm lightning hazard Otherwise you run the
31. ivel in the direction of the arrow 1 press onto the clip 2 and remove it Remove the PCI slot cover 3 U41600 J Z156 1 76 Options Guide 33 Installing the PCI Controller Controllers in PCI Slots CAUTION Keep the slot cover for further use Ifthe controller is removed again and not replaced with a new controller the slot cover has to be reinstalled to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures gt Unpack the new controller and make the desired settings You should read the accompanying documentation supplied with the controller beforehand Figure 20 Installing the controller gt Install the controller into the PCI slot 1 and press it carefully into the associated plug in location on the system board until it engages properly Place the clip onto the slot cover in such a way that the pin a puts into the opening of the cover 2 and press the clip in the direction of the arrow 3 until it engages Swing the swivel 4 in its locking position gt Ifrequired connect the cables to the controller and other components Close the server connect it to the mains and switch it ON as described in chapter Completion on page 37 and following 34 Options Guide U41600 J Z156 1 76 Controllers in PCI Slots Installing the PCI Controller Please check the relevant PCI slot settings in the BIOS Setup Utility D2020 lf nec
32. le gard S II r AY LOLN BZBEA X P P 3 ee aqa Da Kee 301 938 AYd Sp Z Did Zid ZS S ud S K 1 s 8 E 2 g 91d le vivs v 2 a L Aya 1 gt Sid E 1104 aS GGH VLVS O ie 60ZA 92S A z C ISOS 2 8d 2 ndo ade ISOS O ld J mo T Front fan Appendix vemo I LI anna SSS Igued do E L nd vo I LOLA 8V6EA ozoza Josu s duet P1 PSU 35 Service Supplement Figure 23 Basic cabling with four SATA hard disk drives Econel 200 Index E ESD devices sensitive to electrostatic discharge 11 ESD sensitive devices 11 L light emitting diode LED 11 lithium battery 9 M meaning ofthe symbols 3 N notational conventions 3 note about the laser 11 R replacement routines 13 CD DVD drive 19 floppy disk drive 17 front cover 14 front fan 23 ID Combo board 29 intrusion detection switch 28 operating panel cable 15 power supply unit 21 side cover 13 system board 30 system fan 14 temperature sensor 17 s safety 7 T target group 1 Econel 200 Service Supplement 37 Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Commen
33. ler 3 D dual operation 17 dummy module accessible drives 25 E EMC regulations 25 ESD devices sensitive to electrostatic discharge 12 ESD sensitive devices 12 F fan 20 front cover 15 38 H hard disk drives 27 heat sink 19 housing closing 39 opening 13 l information 2 L light emitting diode LED 11 lithium battery 10 M main memory 2 21 meaning of the symbols 3 multiprocessor operating system 17 N notational conventions 3 note about the laser 11 P PCI controller 33 PCI slots 33 processor 2 17 fan 20 heat sink 19 S SATA hard disk drive 3 system fan 16 37 T target group 1 U41600 J Z156 1 76 Options Guide 43 Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on PRIMERGY Econel 200 Server System U41600 J Z156 1 76 Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on PRIMERGY Econel 200 Server System U41600 J Z156 1 76 O FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujit
34. ler is needed The third bay is already occupied with a CD DVD drive The fourth lowest bay 3 5 inch is occupied by a 1 44 MB floppy disk drive Second processor The server can be upgraded to a so called dual processor system A dual processor system needs a multi processor operating system The second processor must have the same type and clock rate as the first 2 Options Guide U41600 J Z156 1 76 Introduction Notational Conventions SATA hard disk drives Upto four SATA hard disk drives can be installed Two SATA hard disk drives are controlled by the onboard SCSI controller If more than two hard disk drives are installed an additional PCI SATA controller is necessary Additional controllers in the PCI slots The system board offers one PCI E Express slot two standard PCI slots 33 MHz and two PCI X slots 66 MHz for additional controllers 1 3 Notational Conventions The following notational conventions are used in this manual text in italics indicate commands menu items or software programs quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data T CAUTION Pay particular attention to texts marked with this lil indicates additional information notes and tips Table 1
35. or removing components containing ESDs e You must always discharge yourself of static charges e g by touching a grounded object before working The equipment and tools you use must be free of static charges Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components e Only touch the components at the positions highlighted in green touch point Do not touch any exposed pins or conductors on a component Place all components on a static safe base You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 Econel 200 Service Supplement 11 4 Replacement Routines CAUTION Refer to the safety notes in chapter Safety on page 7 and following 4 1 General Purposes 4 1 1 Removing Mounting the Side Cover D You will find a detailed description in the Econel 200 Options Guide gt Terminate all applications and shut down the server correctly gt If your operating system has not switched OFF the server press the ON OFF switch gt Unplug the power plug from the power outlet gt f required remove the lock on the side cover gt Loosen the two knurled screws on the rear side of the server and slide the left side cover as far as it will go backward Remove the side cover Proceed in the reverse order for mounting Econel 200 Service Supplement 13
36. ousing and secure it with two screws gt Reconnect the cables Close the server for a detailed description see the Options Guide and reconnect the power plug 4 5 Replacing the CD DVD Drive gt Remove the left side cover and the front panel as described in section General Purposes on page 13 gt Disconnect the power supply cable connector P9 from the CD DVD drive gt Disconnect the data cable T26139 Y3662 V304 from the drive Figure 6 Removing the CD DVD drive Press both tabs ofthe EasyClick rails together 1 and pull out the drive 2 Econel 200 Service Supplement 19 Replacing the CD DVD Drive Replacement Routines Figure 7 Attaching the rails to the CD DVD ROM drive gt Release the two screws and remove the EasyClick rails from the drive gt Unpack the new drive and make the desired settings You should read the accompanying documentation supplied with the drive beforehand gt Mount the EasyClick rails into the lower holes of the new drive two screws gt Push the assembled drive with the rails into the free bay until the EasyClick rails are locked in position gt Reconnect the cables to the new drive Close the server for a detailed description see the Options Guide and reconnect the power plug 20 Service Supplement Econel 200 Replacement Routines Replacing the Power Supply Unit 4 6 Replacing the Power Supply Unit gt Remove t
37. pplement 29 Replacing the System Board Replacement Routines 4 10 Replacing the System Board Remove the left side cover as described in section General Purposes on page 13 Remove the system fan for a detailed description see the Options Guide Remove all cables from the connector panel Lay the server on the right side on a table Remove all cables which may be connected to the system board Y Y Y Y Y Remove the heat sink and the fan from the processor for description see the Options Guide gt Remove all installed controller for description see the Options Guide Take note of the slots of the controllers and the cabling Figure 20 Removing the screws gt Remove the 9 screws from the system board gt Lift the system board slightly using the marked socket of PCI slot 5 In this way you lift the system board out of the centering rings of the spacer bolts 30 Service Supplement Econel 200 Replacement Routines Replacing the System Board gt Carefully remove the system board from the casing at a slight angle This allows you to pull the connectors out of the connector panel gt Place the removed system board on an antistatic surface gt Remove the processor s and the memory modules for description see the Options Guide gt Unpack the new system board place it on an antistatic surface and check the settings for description see the Technical Manual for the system board
38. r condition in the CD DVD drive of your server to prevent data loss damage to the device and injuries e Therefore check each CD DVD for damage cracks breakage etc before inserting it in the drive Please note that any additional labels applied may change the mechanical properties of a CD DVD and cause imbalance Damaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain conditions sharp edged pieces of broken CDs DVDs can penetrate the cover of the drive damage to the device and be thrown out of the device danger of injury particularly on uncovered body parts such as the face or neck You protect the CD DVD drive and prevent mechanical damage as well as premature wearing of the CDs DVDs by observing the following suggestions Only insert the CDs DVDs in the drive when needed and remove them after use Store the CDs DVDs in suitable sleeves Protect the CDs DVDs from exposure to heat and direct sunlight Note about the laser The CD DVD drive is classified for laser class 1 according to IEC 60825 1 CAUTION The CD DVD drive contains a laser diode LED Sometimes the LED produces a stronger laser beam than laser class 1 Direct view into the laser beam is dangerous Never remove parts of the CD DVD drive assembly U41600 J Z156 1 76 Options Guide 11 Safety Modules with electrostatic sensitive components Systems and components that might be damaged by electros
39. risk of losing data if for example the central processing unit is still running but the peripheral device e g storage subsystem has failed during a power outage In emergencies e g damaged casing controls or cables penetration of liquids or foreign matter switch OFF the device immediately remove the power plug and contact your sales outlet or customer service team Proper operation of the system in accordance with IEC 60950 EN EN 60950 is only ensured ifthe casing is completely assembled and the rear covers for the installation openings have been put in place electric shock cooling fire protection interference suppression Service Supplement Econel 200 Safety CAUTION e Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment If you install other expan sions you may damage the system or violate the safety regulations and regulations governing RFI suppression Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet e The components or parts marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel e The warranty expires ifthe device is damaged during the installation or replacement of system expansions e You may only set those resolutions and refresh ra
40. s described in section General Purposes on page 13 Figure 2 Removing the operating panel cable gt Disconnect the operating panel cable from the temperature sensor The temperature sensor is placed under the floppy disk drive gt Remove the operating panel cable from the front panel connector on the system board see D2020 sticker and release the cable from the cable clamp 2 gt Press both tabs of the EasyClick rails together 3 and pull the slide in unit with the operating panel out from the location 4 Econel 200 Service Supplement 15 Replacing the Operating Panel Cable Replacement Routines s Figure 3 Removing the operating panel cable gt Disengage the locking mechanism 1 and remove the bezel from the slide in unit 2 Remove the two LEDs carefully in the direction of the arrow 3 from the holder Release the power button two screws and remove it in the direction of the arrow 4 from the holder Release the cables from the holders 5 and remove them Install the new operating panel cable in the reverse order and reconnect the temperature sensor and the system board Close the server for a detailed description see the Options Guide and reconnect the power plug 16 Service Supplement Econel 200 Replacement Routines Replacing the Temperature Sensor 43 Replacing the Temperature Sensor gt Remove the left side cover as described
41. stem board D2020 PDF file available on the ServerBooks CD D2020 Setup Utility PDF file available on the ServerBooks CD U41600 J Z156 1 76 Options Guide 1 Expansions and Conversions Introduction PRIMERGY ServerView Suite ServerStart PDF file available on the ServerBooks CD LSI SATA Software RAID User s Guide PDF file available on the ServerBooks CD If you need a backup of the ServerBooks CD send the details of your server via email address Reklamat PC LOG fujitsu siemens com Further sources of information manual for the monitor manual for ServerView server management documentation for the boards and drives operating system documentation information files of your operating system see also Related Publications on page 41 1 2 Expansions and Conversions Extension of the main memory The four slots two memory banks with two memory modules each are available for PC2700 DDRI 333 MHz registered SDRAM memory modules Each memory bank can be populated with 512 Mbyte or 1 Gbyte memory modules You find further information on the main memory in the Technical Manual for the system board D2020 PDF file available on the ServerBooks CD Additional accessible drives Two free 5 25 inch bays are available for additional accessible drives CD ROM DVD ROM CD RW DVD DVD R RW CD RW or tape backup drive If a backup drive tape is to be installed a PCI SCSI control
42. su has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format Ots fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at ht1p manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts
43. switch it OFF pull out the power plug and open the server as described in the chapter Replacement Routines on page 13 and following Replace the defective component as described in the relevant chapter Close the server Connect the cables Connect the server to the line voltage Start the operating system Vo vovovovov If necessary configure the server as required Econel 200 Service Supplement 5 3 Safety il The following safety notes are also provided in the Safety manual This device complies with the relevant safety regulations for information technology CAUTION The actions described in this manual should only be performed by service personnel Before operating the device CAUTION e During installation and before operating the device observe the instructions on environmental conditions for your device e f the device is brought in from a cold environment condensation may form both inside and on the outside of the machine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed e Transport the device in its original packaging or in other suitable packaging which will protect it against shock or impact Installation and operation CAUTION e The server automatically sets itself to a voltage in the range of 100 V to 240 V Make sure that your local voltage
44. t DVD or CD drive already available The fourth bay 3 5 inch is already occupied by a 1 44 MB floppy disk drive U41600 J Z156 1 76 Options Guide 23 Installing the Tape Drive Accessible Drives 7 1 Installing the Tape Drive gt Remove the side cover as described in section Opening the Housing on page 13 gt Remove the front cover as described in section Removing the Front Panel on page 15 Figure 12 Removing the dummy module gt Press both tabs of the EasyClick rails together 1 and pull out the dummy module 2 Figure 13 Removing the rails Release the screws and remove the EasyClick rails from the dummy module 24 Options Guide U41600 J Z156 1 76 Accessible Drives Installing the Tape Drive CAUTION Keep the dummy module for future use Ifthe drive is removed again and not replaced with a new drive the dummy module must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire gt Unpack the new drive and make the desired settings You should read the accompanying documentation supplied with the drive beforehand Figure 14 Attaching the rails to the CD DVD ROM drive gt Press the EasyClick rails into the lower mounting holes of the drive two screws Push the assembled drive with the rails into the free bay until the EasyCli
45. tatic discharge ESD are marked with the following label A Figure 1 ESD label When you handle components fitted with ESDs you must observe the following points under all circumstances Remove the power plug from the power socket before inserting or removing components containing ESDs You must always discharge yourself of static charges e g by touching a grounded object before working The equipment and tools you use must be free of static charges Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components Only touch the components at the positions highlighted in green touch point Do not touch any exposed pins or conductors on a component Place all components on a static safe base il You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 Options Guide U41600 J Z156 1 76 4 Preparation CAUTION Refer to the safety notes in chapter Safety on page 7 and following 41 Opening the Housing gt Terminate all applications and shut down the server correctly gt Switch OFF the power supply unit press the main power switch and remove the power plug from the grounded insulated socket gt f required remove the lock on the side cover Figure 2 Loosen the knurled screws gt Loosen the two knurled screws 1
46. tes specified in the Technical data section of the monitor description Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service centre Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the technical manual for the system board e Do not throw batteries into the trash can They must be disposed of in accordance with local regulations concerning special waste e The battery must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board e All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Econel 200 Service Supplement 9 Safety Notes on handling CDs DVDs and CD DVD drives CAUTION Use only CDs DVDs in proper condition in the CD DVD drive of your server to prevent data loss damage to the device and injuries Therefore check each CD DVD for damage cracks breakage etc before inserting it in the drive Please note that any additional labels applied may change the
47. to the mains and switch it ON as described in chapter Completion on page 37 and following Proceed in the reverse order for removal 20 Options Guide U41600 J Z156 1 76 6 Main Memory CAUTION Refer to the safety notes in chapter Safety on page 7 and following The system board supports up to 4 Gbyte main memory Four slots are available two slots each form a memory bank for the main memory Each memory bank can be populated with two 512 Mbyte or 1 Gbyte registered DDR RAM PC2 2700 memory modules The basic unit includes the first memory bank populated either with 1x 512 Mbyte 1 Gbyte or 2 Gbyte ECC with memory scrubbing and with Single Device Data Correction SDDC Chipkill function is supported 6 1 Slot Population Rules Bank 1 DIMM 1A r Bank 1 DIMM 1B Bank 2 DIMM 2A l E Bank 2 DIMM 2B 22 E Figure 9 Structure of the main memory in memory banks and memory modules The modules capacity can be different for the different memory banks e g pair 1A 1B can be populated with two 512 Mbyte modules and pair 2A 2B with two 1 Gbyte modules Following table shows the mandatory population order channel DIMM 1A bank 1 512 MB 512MB 1GB 512MB 1 GB A DIMM 2A bank2 z 1GB 1GB channel DIMM 1B bank 1 512MB 1GB 512MB 1GB B DIMM 2B bank 2 1GB 1GB memory size 512MB 1GB 2GB 3GB 4GB
48. ts on PRIMERGY Econel 200 Server System Econel 200 Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on PRIMERGY Econel 200 Server System Econel 200 PRIMERGY Econel 200 Server System Options Guide Edition December 2004 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright O 2004 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers This manual
49. ual Never connect or disconnect data transmission lines during a storm lightning hazard Otherwise you run the risk of losing data if for example the central processing unit is still running but the peripheral device e g storage subsystem has failed during a power outage Options Guide U41600 J Z156 1 76 Safety CAUTION e In emergencies e g damaged casing controls or cables penetration of liquids or foreign matter switch OFF the device immediately remove the power plug and contact your sales outlet or customer service team e Proper operation of the system in accordance with IEC 60950 EN 60950 is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place electric shock cooling fire protection interference suppression e Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment If you install other expan sions you may damage the system or violate the safety regulations and regulations governing RFI suppression Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet e The components or parts marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel e The warranty expires if the device
50. y unit Replacing the system fan Replacing the front fan Replacing the intrusion switch Replacing the system board Service Supplement BIOS setup BIOS Setup Utility Table 1 Overview of the Documentation Econel 200 2 Service Supplement Econel 200 Introduction Notational Conventions 1 2 Notational Conventions The following notational conventions are used in this manual text in italics indicate commands menu items or software programs quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown CAUTION Pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data D indicates additional information notes and tips Table 2 Notational conventions Econel 200 Service Supplement 3 2 Procedure CAUTION The actions described in this manual should only be performed by service personnel Before doing anything else please take notice of chapter Safety on page 7 and following gt Make sure all necessary manuals see service CD are available possibly print of the PDF files You will definitely need the Operating Manual and the Options Guide for the server and the Technical Manual for the system board Shut down the server correctly

Download Pdf Manuals

image

Related Search

Related Contents

Bionaire BCM630CN05EFM1 Humidifier User Manual  MANUAL DE USUARIO  RCA 26790 Cordless Telephone User Manual  Impex NS-1201E Owner's Manual  Manuel d`instructions  HP Deskjet D2600 Printer series  MLN juillet 09.indd - Mandelieu La Napoule  Video - Lassane  Victory Refrigeration UFS-2-S7 User's Manual  ACTIVE STEAM IRON WITH ANTI-SCRATCH TIP FER A  