SR500A DC/DC converter
Contents
1. Specifications are subject to change without prior notice 5 6 09 12 energies PARALLEL CONNECTION Two or more SR500D or SR500L converters may be connected in parallel for increased power with or with out diodes or N 1 redundancy with external diodes as shown below It is recommended that the wiring from each unit to the load is kept identical for equal power sharing particularly when diodes are not used SRxxx D o o E MY LOAD o E d a Lull ALARMS SRxxx D ae Hil ALARMS Fig 1 Two SR500 D with external diodes Specifications are subject to change without prior notice Notes Specifications are subject to change without prior notice LY CNergles TERMS OF WARRANTY Innovative Energies Ltd warrants its power supplies for 24 months two years from date of shipment against material and workmanship defects Innovative Energies liability under this warranty is lim ited to the replacement or repair of the defective product as long as the product has not been damaged through misapplication negligence or unauthorized modification or repair Thank you for purchasing from Innovative Energies We trust your power supply will exceed your expectations and perform for years to follow Sincerely The Innovative Energies team Innovative Energies Limited Phone 64 9 835 0700 Freephone 0800 654 668 New Zealan
2. ovative Q pur O F Q gt energies User Manual ISO9001 Certified SR500A DC DC Converter Optional V I meter shown Model Codes SR500A Standard SR500D Standard with alarms SR500L D version with high volts alarm not available for gt 48VDC output versions Specifications are subject to change without prior notice www innovative co nz 6 09 12 energies Safety The user is responsible for ensuring that input and output wiring segregation complies with local standards and that in the use of the equipment access Is confined to operators and service personnel A low resistance earth connection is essential to ensure safety and additionally satisfactory EMI suppression see below HAZARDOUS VOLTAGES EXIST WITHIN A POWER SUPPLY ENCLOSURE AND ANY REPAIRS MUST BE CARRIED OUT BY A QUALIFIED SERVICEPERSON Electrical Strength Tests Components within the power supply responsible for providing the safety barrier between input and output are con structed to provide electrical isolation as required by the relevant standard However EMI filtering components could be damaged as result of excessively long high voltage tests between input output and ground Please contact our techni cians for advice regarding electric strength tests Earth Leakage The EMI suppression circuits causes earth leakage currents which may be to the maximum allowable of 3 5mA Ventilation High operating temp
3. 4 3 Kg Efficiency gt 85 Standard Power OK Standby With alarms DC OK Power OK Standby Indication LEDs Inrush current Soft start circuit Standby switch OPTIONS Turns off DC output Output power 500W Output voltage 13 8 24 30 36 48 96 108 120VDC Line regulation lt 0 2 over input range Alarms SR500D Input fail or converter in standby mode Load regulation lt 0 4 open circuit to 100 load DC low set at 83 V out Noise lt 1 SR500L As SR500D DC HIGH alarm Drift 0 03 C Earth fault using external alarm card Hold up time 15 20ms Alarm contacts C NO NC changeover rated 1A 50V DC 32VAC Thermal protection Yes self resetting Communications Port Choice of RS485 RS232 ethernet SNMP or ASCII Available only on SR500L models STANDARDS EMI To CISPR 22 EN55022 class A C tick Internal V I meter Add code INT METER Safety To IEC950 EN60950 AS NZS3260 ENVIRONMENTAL Operating 0 to 50 C ambient at full load temperature De rate linearly gt 50 C to no load 70 C Output fuse Fitted on rear panel ACCESSORIES SUPPLIED Mounting feet together with screws Storage temperature 10 to 85 C ambient Humidity 0 95 relative humidity non condensing Mating screw terminal plug for alarm outputs Crimp lugs for stud terminal versions Cooling Fan cooled DC screw terminal plug in connector for X version
4. is to ensure that the current rating of the terminal block is not ex ceeded CONNECTION LAYOUT fel ede H O DC OUTPUT DC OUTPUT Screw Conn Output Stud Conn Output 3 LED INDICATION CODES 3 1 A Standard version LED INDICATION 1 POWER OK LED indicates POWER Ok DC present on output terminals either from PSU or battery if DC PRESENT connected STANDBY DC ABSENT LED INDICATION 3 2 D Alarm version DC OK POWER OK STANDBY NORMAL DC LOW STANDBY As above 2 DC OK LED indicates DC output is present either from converter or battery if connected 3 POWER OK LED indicates input power on unless there is a short circuit on the output 4 DC LOW settings as in para 3 3 Specifications are subject to change without prior notice ovative energies 3 3 L version with DC high alarm DC OK LED Slow flash DC LOW __ Settings PSU 0 83 xVnom Charger 1 83V cell Fast flash DC_ HIGH Settings PSU 1 2 x Vnom Charger 2 5V cell 4 ALARM TERMINAL LAYOUT for D amp L versions Relay contacts shown in de energised state ie when there is a fault condition Alarm relays are energised when power supply is operating normally No DC HIGH alarm relay fitted on gt 48VDC versions eg SR500L92 108VDC output 5 FG Frame Ground Where provided this terminal provides a connection to the metal case for an earthing point 6 STANDBY FUNCTION Pu
5. d 1800 148 494 Australia Fax 64 9 837 3446 Email info innovative co nz Online www innovative co nz In Person 1Heremai Street Henderson Auckland New Zealand By Post PO Box 19 501 Auckland 1746 New Zealand Specifications are subject to change without prior notice
6. erature is a major cause of power supply failures for example it has been well documented that a 10 C rise in the operating temperature of a component will halve its expected life Therefore always ensure that there is adequate ventilation for the equipment Batteries and cooling fans also suffer shortened lifetimes if subjected to high ambient temperatures both should be included in a routine maintenance schedule to check for signs of reduced effi ciency Water Dust Every effort must be made in the installation to minimise the risk of ingress of water or dust Water will almost always cause instant failure The effects of dust are slower in causing failure of electronic equipment but all electrical equip ment should be cleaned free of any dust accumulation at regular intervals This is particularly important where internal fans are fitted Electromagnetic Interference EMI Switching power supplies and converters inherently generate electrical noise All wiring should be as short as practica ble and segregated from all equipment wiring which is sensitive to EMI Residual noise can be reduced by looping DC wiring through ferrite cable sleeves These are most effective as close to the power supply as possible and as many turns of the wire taken through the core and in the same direction as the core will accommodate Fuse ratings Check that the wiring and fuses or MCBs match the rating of the PSU or converter Adequate fuse protection o
7. f battery circuits is very important owing to the large potential currents available from batteries Connection polarity It is critical to check the polarity carefully when connecting DC power supplies and chargers to equipment Boost chargers and some float chargers usuall have reverse polarity protection RPP which can be electronic non destructive or by an internal fuse which needs to be replaced if a battery is connected in reverse Glossary of terms used in our user manuals PSU power supply unit BCT battery condition test ECB electronic circuit breaker ELVD electronic low voltage disconnect RPP reverse polarity protection EMI electromagnetic interference SNMP Simple Network Management LAN local area network DOD depth of discharge Protocol Specifications are subject to change without prior notice 2 ovative energies 1 INTRODUCTION The SR500A version described in this user manual is a DC DC converter suitable for 110VDC input 2 CONNECTIONS If used as a float charger always connect the positive output of the power supply to the positive terminal of the battery The charger may be permanently connected to float charge lead acid batteries but it is essential to periodically check the electrolyte level of flooded cells as there is always some evaporation Where screw plug in terminals are fitted on the 24V model there are two terminals provided for each polarity and both terminals must be used This
8. shing the STANDBY button turns the output of the power supply off If there is a battery con nected the DC OK LED remains on even though the power supply is turned off Specifications are subject to change without prior notice iS N YZ yr ovative energies www innovative co nz DC DC converter incl SR500D SR500L e isolated input to output e Designed amp built to industrial standards e Standalone bench top or fixed mounting op tional rack mount 2U x 19 e Front panel controls amp indication e Conservative design for long life e Precise voltage control e Optional relay alarm outputs e Optional communications port RS232 RS485 or Ethernet protocols available Modbus SNMP or ASCII code Optional internal V I meter shown Z367 24 Month Warranty SPECIFICATIONS All specifications are typical at nominal input full load and at 20 C unless otherwise stated PHYSICAL ELECTRICAL Input Fusing Overload protection 88 135VDC Input fuse Primary current limit external output fuse Input connector Output connector Alarm connectors opt Screw terminals M8 brass stud or plug in screw terminal block Plug in screw terminal block must be fitted for short circuit protection Enclosure Powder coated steel Isolation 1KV DC input output earth l Dimensions 225W x 70H x 304D mm excl terminals Output over voltage Output limited to 130 Vnom Weight
Download Pdf Manuals
Related Search
Related Contents
Marmitek DS831 Lettre du 20 décembre 2013 - Les services de l`État en Mayenne Please read manual carefully before starting experiment RayBio "service manual" UFT14型およびUFT32型ユニバーサル型フロート式 Certificat de conformité hors sol Delphin Jensen SMPS-600 User's Manual Installation & Quick Start Guide Copyright © All rights reserved.