Home
FUM-1215CBPH / FUM-2407CBPH FUM-1230CBPH
Contents
1. Formula Charging time will depend on the capacity oy your battery and on how deeply is discharged The following equation calculates an approximate charging time CAP x DOD Charging time _ CC x 80 Where Charging time battery recharge time in hours CAP Battery capacity in ampere hours DOD Battery depth of discharge in per cent A fully discharged battery has a 100 DOD CC Charge current the rated current output of the charger in amperes 80 Typical charging efficiency fo lead acid batteries Example A group size battery rated at 100 amp hours is 40 discarged that is it has a DOD 40 Carging time with a FUM 1215CBPH is calculated as follows 100Ah x 40 Charging time 3 3 hours 15A x 80 Discharging time To achieve 50 cycling you should calculate your amp hour consumption between charging cycles and use a battery bank with twice that capoacity To calculate Amp hour consumption fisrt look at the rating plate on your AC appliance or tools Each appliance or toll will be rated in either AC amps or AC watt or AC VA volt amperes apparent power Use one of the following to calculate the DC amp hour draw for a 12V system AC amps x 10 if mains is 120VAC x 1 1 x hours of operation DC amp hours AC amps x 19 1 if mains is 230VAC x 1 1 x hours of operation DC amp hours AC watts 12 x 1 1 x hours of operation DC amp hours AC VA 12 x 1 1 x hours of operati
2. 0 00 OW GT a No FullWwat FUM 1215CBPH FUM 2407CBPH FUM 1230CBPH FUM 2415CBPH FUM 1260CBPH FUM 2430CBPH Multistage battery charger User manual Design Features PFC function except FUM 1215CBPH and FUM 2407CBPH Sleeping mode function Wide input voltage universal range operation except FUM 1215CBPH and FUM 2407CBPH LCD remote control Battery temperature sensor function Tri LED color indicator for different charge stage Adjustable charging mode switch for different lead acid battery types Prevent the battery overcharging and extend the battery life For recovery of the aging sulfated battery List of contents Important safety INStrUCtIONS cccccecccesseesceesseesscecssecsseeseeceaeesseeceaeesaeessaessseeseneeeaees 1 Installation location physical requirements for installation cscccssesseeseesteeeees 1 Charger OVERVIOW cccccccnesceelesevarvnacesttyecctaneyesdtasacateacduacedecsdania Cesenanedecvisvaretavesetesttecanseede 2 installation diagraMS ci iccsccea ccecsicesetcsnsepsnadsshesecensesacuvacdecha tassenestssuscestodecess Cadena sueeanieste 4 Charging voltage graphice deeded 5 Charger LCD remote CONIO cecccesecsseceseecseecseeessecsseecsaeeeeessaescatessueesneeseseesseessneess 6 Technical specifications i iecisvcies sce caaseeendtestvddcestvieleiiveccvedassianveteesaveecettesine a esedeteecetie late 7 Charging and discharging fOrmulde cccsccsssccsssesseessee
3. 1A 1A 1A 30A 30A Bulk stage 14 1V 15 3V 12 2V 13 5v 28 2v 30 6v 25 4v 27v 13 3V 60A 2A 2A 60A 60A 30 0M 30A 1A 1A 30A 30A Absortion stage 14 7v 14 1v 14 1v 14 1v 15 3v 12 2v 13 5v 29 4v 28 2v 28 2v 28 2v 30 6v 24 5v 27v I 60 0A 60 0A 6o oa 2 0A 2 0A 60A 60A 30 0A 30 0A 30 OA a oa 1 0A 30A 30A Absortion stage 13 5V 30 6V II 4A max 1A max Float stage 13 5V 2A max pa pen 27V 1A max pry ae Max current 60A 30A Conti ontinous 60A 30A current Recommended 180 600 Ah 12V a 90 300 Ah 24V a battery capacity Leakage current LIHA _ eae _ from battery Sleeping mode f nctio Yes 5A current output only Yes 2 5A current output only PROTECTION Overtemperaturd 55 5 2C 131 9 2F Overload Yes Oo ia utput short Yes circuit Microprocessor p Yes check ENVIRONMENT Working 15 45 2C 5 113 F temperature ade 20 90 RH non condensing storage 30 70 2C 22 158 F 10 95 RH conditions Temperature 0 05 2C 0 50 2C 32 122 2F coefficient ec OTHER Remote control Yes Dimension 335 x 142 x 72 mm Lx W x H Weight 3 5 Kgs Specifications subject to change without notice Tolerance for specifications 0 5V for 12V spec 1V for 24V spec 10 for current data User s manual 9 FUM 12xxCBPH 24xxCBPH FullWwat 8 Charging and discharging formulae Charging time
4. color inimi la nF Mode 4 020 Mode 5 023 Suitable for recovery sulfated gel battery i e diacharged batteries unused for long periods or the battery that never recharges completely This mode should be applied with the battery standby completely disconnected from orange the devices it runs Suitable for recovery sulfated lead storage battery i e diacharged batteries unused for long periods or the battery that never recharges completely This mode should be applied with the standby red lorange green gt LED color battery completely disconnected red from the devices it runs red green gt LED color AAA Mode 6 123 DC power supply 12 2V for 12V spec 24 5V for 24V spec Wi ol Mode 7 000 DC power supply 13 5V for 12V standby spec 27V for 24V spec green green 2 LED color User s manual FUM 12xxCBPH 24xxCBPH Fullwat 6 Charger LCD remote control fault indicator ON OFF battery volt ON OFF battery capacity ON OFF switch charging mode charging current power supply DC output volt fault indicator red lighting ON OFF ON OFF output current ON OFF switch 5 Mode 6 7 power supply mode 6 Over temperature protection fault indicator red lighting ON OFF 7 High battery volt protection User s manual 6 FUM 12xxCBPH 24xxCBPH Full
5. ventilation openings on the unit are not obstructed If mounting in a compartment ventilate the compartment with louvres or cut outs to prevent overheating Close to AC ee o Avoid the use of extended wire lengths if possible junction box Close to Avoid excessive cable lengths and use the recommended wire lengths and sizes batteries Undersized or overly long cables may affect charging accuracy 3 Inverter operation FUM 1215CBPH FUM 2407CBPH FUM 1230CBPH FUM 2415CBPH A Warning Don t reverse the and of the battery Or internal damage will result DC OUTPUT Black Sleeping Mode Normal Mode Note 1 Note 2 Charging Status Charging Mode Selection Please refer to page 5 Battery Temp Sensor Note 3 FUM 1260CBPH FUM 2430CBPH A Warning Don t reverse the and of the battery Or internal damage will result DC OUTPUT main Red Black ellie Sleeping Mode Note 1 Note 2 Slave Switch Note 4 Charging Status Remote control LCD Charging Mode Selection Please refer to page 8 Note 1 Sleeping mode Fan would stop and the charger working sound would be smaller so the output current would be 5A 12V spec or 2 5A 24V spec User s manual 2 FUM 12xxCBPH 24xxCBPH FullWwat Normal mode The charger would work as it maximum capacity according
6. 5A Conti ontinous 30A 15A current Recommended 75 250 Ah 12V 45 150 Ah 24V battery capacity Leakage current ey _ ae _ from battery Sleeping mode Yes SA current output only Yes 2 5A current output only function PROTECTION Overtemperaturd 55 5 2C 131 9 2F Overload Yes Output short Yes circuit Microprocessor Yes check ENVIRONMENT Working 15 45 2C 5 113 F temperature ade 20 90 RH non condensing storage 30 70 2C 22 158 F 10 95 RH conditions Temperature 0 05 2C 0 50 2C 32 122 2F coefficient ec OTHER Remote control Yes Dimension 252 x 142 x 72 mm Lx W x H Weight 2 5 Kgs Specifications subject to change without notice Tolerance for specifications 0 5V for 12V spec 1V for 24V spec 10 for current data User s manual ao FUM 12xxCBPH 24xxCBPH FullWwat Model FUM 1260CBPH FUM 2430CBPH INPUT Voltage range 90 264VAC Frequency range 45 65 Hz Efficiency 285 Power factor 1 0 at full load 5 Input socket IEC plug OUTPUT Mode selection M1 M2 M3 M4 M5 M6 M7 M1 M2 M3 M4 M5 M6 M7 Standby 14 7V 14 1V 14 1v 14 1v 15 3v 12 2v 13 5v 29 4v 28 2v 28 2v 28 2v 30 6v 25 4v 27v 2A 2A 2A 2A 2A 60A 60A 1A 1A
7. Wwat 7 Technical specifications Model FUM 1215CBPH FUM 2407CBPH INPUT Voltage range 180 264VAC Frequency range 45 65 Hz Efficiency 285 Power factor 0 5 at full load 5 Input socket IEC plug OUTPUT Mode selection M1 M2 M3 M4 M5 M6 M7 M1 M2 M3 M4 Standby 14 7V 14 1V 14 1V 14 1V 15 3V 12 2V 13 5V 29 4V 28 2V 28 2V 28 2V 1A 1A 1A 1A 1A 15A 15A 0 5A 0 5A 0 5A 0 5A M5 30 6V 0 5A M6 25 4V 7A M7 27V 7A Bulk stage 14 1v 15 3V 12 2v 13 5V 28 2V 15 3V 15A iA ta ane aan 30 6V 7A ak 30 6V 0 5A 25 4V 7A 27V 7A Absortion stage 14 7V 14 1V 14 1V 14 1V 15 3V 12 2V 13 5V 29 4V 28 2V 28 2V 28 2V I 15 0A 15 0A 15 0A 1 0A 1 0A 15A 15A 7 0A 7 0A 7 0A 0 5 0A Absortion stage i3 5V 30 6V II T T 1A max 0 54 max 30 6V 0 5 0A 24 5V 7A 27V 7A Float stage 12 2V 13 5V 13 5V 1A max 15A 15A 27V 0 5A max 24 5V 7A 27V 7A Max current 15A 7A Continous current 15A 7A Recommended battery capa ity 45 150 Ah 12V 30 90 Ah 24V Leakage current from battery Sleeping mode function lt 1mA lt 1mA Yes SA current output only Yes 2 5A current output only PROTECTION Overtemperaturd 55 5 2C 131 9 2F Overload Yes Output short Pan Yes circuit Microprocessor che
8. a sharp blow been dropped or otherwise damaged in any To avoid a risk of fire and electric shock make sure that existing wiring is in good electrical conditions and the wire size is not undersized Do not operate the inverter with damage or substandard wiring 2 Installation location physical requirements for installation Condition Description Clean Do not expose the charger to metal filings or any other form of conductive contamination The presence of conductive contamination can cause damage and void your warranty Cool For best performance the ambient air temperature should be between 15 C 5 F and 45 C 113 F the cooler the better At higher ambient temperatures the output current will be automatically reduced to protect the charger from high internal temperatures Dry The unit is intended for use in a dry location Do not allow water or other fluids to drip or splash on the charger Do not mount the charger in an area subject to rain spray or splashing bilge water Safe This battery charger is Ignition Protected so it can be installed in areas containing gasoline tanks or fittings which usually require Ignition Protected equipment It is safest not to install electrical equipment in these areas User s manual 1 FUM 12xxCBPH 24xxCBPH Condition Description Ventilated Allow at least 10 cm 4 inches of clearance around all sides of the charger for air flow Ensure that the
9. ck yes ENVIRONMENT Working 15 45 C 5 113 F temperature Working humidity Storage conditions 20 90 RH non condensing 30 70 2C 22 158 F 10 95 RH Temperature 2 9 o coefficient 0 05 2C 0 50 2C 32 122 2F OTHER Remote control Yes Dimension 213 x 142 x 72 mm Lx W x H Weight 1 9 Kgs Specifications subject to change without notice User s manual 7 FUM 12xxCBPH 24xxCBPH FullWwat Model FUM 1230CBPH FUM 2415CBPH INPUT Voltage range 90 264VAC Frequency range 45 65 Hz Efficiency 285 Power factor 1 0 at full load 5 Input socket IEC plug OUTPUT Mode selection M1 M2 M3 M4 M5 M6 M7 M1 M2 M3 M4 M5 M6 M7 Standby 14 7V 14 1V 14 1v 14 1v 15 3v 12 2v 13 5v 29 4v 28 2v 28 2v 28 2v 30 6v 25 4v 27v 2A 2A 2A 2A 2A 30A 30A 1A 1A 1A 1A 1A 15A 15A Bulk stage 14 1V 15 3V 12 2V 13 5v 28 2v 30 6v 25 4v 27v 1 3V30A 2A 2A 30A 30A 30 6V 15A 1A 1A 15A 15A Absortion stage 14 7v 14 1v 14 1v 14 1v 15 3v 12 2v 13 5v 29 4v 28 2v 28 2v 28 2v 30 6v 24 5v 27v I 30 0A 30 0A 3070A 2 0A 2 0A 30A 30A 15 OA 15 OA 15 OA 1 0A a oa 15A 15A Absortion stage 13 5V 30 6V II 2A max 1A max Float stage 13 5V 2A max EA EN 27V 1A max A aa Max current 30A 1
10. on DC amp hours In all formulas 1 1 is the factor for inverter charger efficiency Calculate the above for every AC appliance or tool you intend to use on your inverter This will give you the total number of amp hours used between recharges Size your battery bank using this number as a guideline A good rule to follow is to size the battery bank about two times mlarger than your total amp hour load requirement Plan on recharging when 50 discharged Many electrical motors have momentary starting requirements weel above their operational rating Strt up watts are listed where apprpiate Individual styles and brands of appliance may vary User s manual 10 FUM 12xxCBPH 24xxCBPH Fullwat NOTICE Lead acid battery is recommended for inverter charger models also the LiFePO batteries 9 Warranty We offer 12 months warranty from the date of purchase as stated in invoice or purchasing proof and will repair or replace any defective power invertir This limited warranty is void if the unit is abused modified installed improperly if the housing has been removed if the serial number is missing or if the original identification markings have been defaced altered or removed The supplier is not liable for any incidental consequential or other damages arising from the use cost of removal installation or troubleshooting of the customer s electrical systems Repair or replacement are your sole remedies and shall not be liable f
11. or damages whether direct incidental special or consequential even though cause by negligence or other fault This is only warranty and the company makes no other warranties express or implied including warranties of merchantability and fitness for a particular purpose v2 01 2013 User s manual 11 FUM 12xxCBPH 24xxCBPH
12. quipment in which the battery is installed User s manual 3 FUM 12xxCBPH 24xxCBPH Fullwat 4 Installation diagrams Before charging read the instructions for indoor use only Disconnect the supply before making or breaking the connection to the battery black negative red positive FUM 1215CBPH FUM 2407CBPH FUM 1230CBPH FUM 2415CBPH Main battery the red Cable Note 5 red positive 2nd battery the red terminal red positive black negative DC Negative Bus FUM 1260CBPH FUM 2430CBPH Note 5 Please connect the main battery cable prior to 2 battery ternminal if you just have 1 battery User s manual 4 FUM 12xxCBPH 24xxCBPH FullWwat 5 Charging voltage graph Mode 1 100 Suitable for recharging lead storage battery Mode 2 120 Suitable for recharging gel Eme standby storage battery eran ri e red orange Pes LED color is Mode 3 003 Suitable for recharging lead storage battery which is in good condition no sulfated situation and completely disconnected from the devices it runs because this mode has the additional stage the battery may reach voltage too high for standby them And the limited current orange delivered by the battery charger This is not able to provide power for devices and simultaneously charge the battery red lorange green gt LED
13. sseecseeceeeeseessseesseessaeesseeseneess 10 Warranty ennenen a aa S ATE EEE EA 11 FullWwat 1 Important safety instructions WARNING Before installing and using the charger read all instructions and cautionary marking on the charger the batteries and all appropriate sections of this guide General safety precautions Do not expose the charger to rain snow spray or bilge water To reduce risk of fire hazards do not cover or obstruct the ventilation openings Do not install the inverter in a zero clearance compartment Overheating may result The charger is designed to be permanently connected to your AC and DC electrical systems Never use chagers at a location where there is a danger of gas or dust explosions Use only attachments recommended or sold by the manufacturer Doing otherwise may result in a risk of fire electric shock or injury to persons Do not disassemble the charger Attempting to service the unit yourself may result in a risk of electric shcok of fire Internal capacitors remain charged after all power is disconnected The charger must be provided with an equipment grounding conductor connected to the AC input groung To reduce the risk of electrical shock disconnect both AC and DC power from the charger before attempting any maintenance or cleaning or working on any circuits connected to the charger Turning off controls will not reduce this risk Do not operate the charger if it has received
14. to its specifications Fan would run if it is necessary Note 3 Note 2 Battery temperature sensor To detect the battery temperature while charging please connect wire sensor to the battery housing metal part touches battery housing by adhesive or tape Note 4 The slave switch of the remote control just cuts out the output If you want to turn off the charger completely please switch off main switch of charger body Mounting Bracket optional accessory E bs E amf am FRONT VIEW SIDE VIEW TOP VIEW SIDE VIEW a ISOLATED DESIGN The DC battery charging circuits of this charger are galvanically isolated by a transformer from the AC power circuits This feature reduces the risk of electric shock b WARNING Explosive gases Prevent flames and sparks Provide adequate ventilation during charge Include a warning against recharging non rechargeable batteries If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent c Explosive gas precautions 1 The charger have been approved as Ignition Protected They may be installed in areas containing gasoline tanks and fittings which require Ignition Protected equipment It is safest not to install electrical equipment in these areas 2 To reduce the risk of battery explosion follow these instructions and those published by the battery manufacturer and the manufacturer of the e