Contents
1. SANN 9 1 MN 11 2 1 6 Ve ole 8 labs ae B I a EA ee ee nee ee eee eee 12 2 1 6 1 The Non W amp M approved ICON ccccccessccessseesssseeessssecsseeessssnsessssseesssssessssseessasesseas 12 210a 10 9 162 000 GO EE 12 Z163 LED TMe INCI Cel 10 EEE REE 12 3 Miscellaneous FONTANA eee anta 13 ESN 13 32 le PN 13 3 2 1 Command Line Parameters Example rrnrrrrnnrrrnnvrrnnnrrnnnvennnvrrsnvrrnnnvenssnvensnvnrnsnvrnsnnnrnnn 13 Appendix A Trouble Shooting Attention Scan rrrrrrnvvrnnnvrrnnvrnnnvrrnnnvennnvrrnnnvrnrnnvennnvrrnnnnsrnnvnssnvrssnnsne 15 Honeywell Enraf Attention Scan Instruction Manual 3 1 Overview Attention Scan is an Entis Pro add on It is installed on one or more Entis Pro workstations and intended to view level data from user selectable gauges with increased update rates Attention Scan connects to Enraf s Gauge Data Server EGDS Attention J Att entio n Attentio n Scan CIU Plus nt 2 J TE IU Prime HIMS HTG H04 Smartradar Hybrid Hydrostatic Tank gauging 3 Servo Tank gauging Smartradar Tank gauging Figure 1 Typical configuration Attention Scan together with EGDS Enraf Gauge Data Server forms a Client Server application One or more Attention Scan clients can be connected to one or more EGDS servers This is only limited by bandwidth usage Honeywell Enraf Attention Scan Instruction Manual 2 Getting Started First Use The applicati
2. Instruction Manual Entis Pro Attention Scan February 2013 PART NO 4416386 REV 0O Honeywell Enraf Attention Scan Instruction Manual 1 Honeywell Enraf Preface This manual describes how to operate the Entis Pro Attention Scan It has been written for system supervisors as well as engineers to provide them with all information to configure the system Safety and prevention of damage Notes have been used throughout in this manual to bring special matters to the immediate attention of the reader A note points out a statement deserving more emphasis than the general text Please do not hesitate to contact Honeywell Enraf or its representative if you require additional information Contact Information Head Office Delft the Netherlands Honeywell Enraf Delftechpark 39 2628 XJ Delft PO Box 812 2600 AV Delft The Netherlands Tel 31 0 15 2701 100 Fax 31 0 15 2701 111 E mail enraf helodesk honeywell com Website http www honeywell com ps 2013 Enraf B V Legal aspects The information in this manual is copyright property of Enraf BV the Netherlands Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by e Deviation from any of the prescribed procedures e Execution of activities that are not prescribed Attention Scan Instruction Manual Contents k VINN 4 gt STN a EE 5 2 am 08 10 EEE EE es 6 Zale TNT 7 ET N 3 EE EE 8 DEN SUM 9
3. NGAUGE_APPLICATI Occurs when a COM port is ON ERROR claimed by another application Possible double use of serial port Check for LOSE ERROR in use by another EGDS client other application that uses the serial port COULD NOT GREAT The application tries to open a remote port E SERIALDEVIGE E Occurs when serial port does that is not there Check Instrument RROR not exists configuration with the configuration tool Occurs when timeout Latency timeout value configured out of turnaround delay or retries are range Try to use a smaller non negative CONFIG ERROR out of range value or the default 5000ms Honeywell Enraf Attention Scan Instruction Manual 15 Occurs when the error is DEVICE UNKNOWN unknown Global exception in ERROR the code 1 If an illegal device is selected Serial Port number out of range Valid range Not COM1 255 or UDP TCP 1 31 through GUI 1 255 in XML configuration DEVICE ILLEGAL E 2 If the serial port configuration RROR is failing 1 When a client cannot No network connection Check network connect to the EGDS server cabling IP addresses and Firewall settings both at the client and the EGDS server 2 When the Ethernet layer machine NETWORKCONNECT UDP TCP of the EGDS server ION DENIED ERRO cannot connect to a R Gateway Device No network connection or performance issue Check network cabling reduce number of Attention Scan clients Check NETWORKCONNECT When client is losing Firewall settings
4. and the time indication Watchdog are used to indicate the health of the application The time system indication displays the local system time If the time appears to be stopped normal operation of the application is disrupted and eventual displayed data cannot be relied upon If the LED indicator seem frozen in either state lit or extinguished the application has difficulties retrieving valid data from the instrument Honeywell Enraf Attention Scan Instruction Manual 12 3 Miscellaneous Functionality 3 1 Always On top Since it is a monitoring application the Attention Scan application is configured for always on top use By minimizing the application it disappears from the desktop and active scanning is stopped to minimize bandwidth usage Upon restoring the application the scanning will resume If the Windows 7 Aero theme is configured in windows the minimized preview thumbnail will look like figure 10 AttentionScan Product Level it Ei GN Figure 10 Aero theme thumbnail preview The actual tank select is shown the tooltip describes the stopped situation 3 2 Command line Parameters During the installation a shortcut is made to the application in the Windows Start Menu only since it is part of the Entis Pro suite It is however possible to create your own shortcut with preconfigured group and instrument parameters lt Group Name gt and lt Instrument Name gt will have to be provided as parameters to Att
5. Attention Scan Instruction Manual 9 Honeywell Enraf Attention Scan Instruction Manual 10 2 1 5 Help The Help Button will show the user manual this file a non contextual help in PDF format Instruction Manual Entis Pro Attention Scan Figure 9 Coversheet Please note that hovering over the Help button will show the application About text It is important for the Help function to operate correctly that a suitable PDF reader is installed Honeywell Enraf Attention Scan Instruction Manual 11 2 1 6 Application Status Bar 16 27 18 The Status bar consists of three elements e The Non W amp M indication to indicate the application is not suitable for custodial processes e The application status indicating current action or error situations e The Watch dog LED Time indication indicating the health of the application 2 1 6 1 The Non W amp M approved icon da The main purpose of the application is high speed level scan The application is not certified for custodial transfer Therefore the Non W amp M indication indicates that the shown data is not suitable for custodial transfer 2 1 6 2 Application Status AttentonScan 1 0 0 0 The Application Status indicates the current status of the program Possible messages are application activities and or error conditions codes with a expanded description in the tooltip 2 1 6 3 LED Time indication 16 77 18 Both the LED yellow
6. both at the client and the ION LOST ERROR connection with the server EGDS server machine The application beside the error code name will also show an error number This is mainly intended to communicate to the service engineer in case of a support contact Honeywell Enraf Attention Scan Instruction Manual 16
7. ention Scan separated by a space and in this order Attention Scan will load the correct group and instrument and begin scanning 3 2 1 Command Line Parameters Example Step 1 Create a shortcut to the executable located in C Program Files Honeywell Enraf AttentionScan AttentionScan exe Refer to the Windows Help system on how to do this Honeywell Enraf Attention Scan Instruction Manual 13 Step 2 Open the properties of the shortcut i Am Attention Scan exe Shortcut Target type rer Target location Attention Scan Target Tat Attention Scan AttentionScan exe Start in CA Program FilesyvHoneywell EnrafiAttention Scar Shortcut key None Figure 11 Shortcut parameters Step 3 Change the Parameters to suit your needs In the shown example the ALL group and a Tank TK 01 note the space between the group and the tank is added to the shortcut This forces the Attention Scan application to start with the TK 01 tank from the ALL group to be preselected Step 4 Apply the settings and close the dialog by clicking the OK Button Honeywell Enraf Attention Scan Instruction Manual 14 Appendix A Trouble Shooting Attention Scan NO ERROR Occurs when there is no error This normally not shown Noise or instability Check Serial Connections between PC and CIU and or BCC ERROR Serial message checksum CIU field lines Check cable shielding Noise or instability Check Serial Connections betwee
8. instrument cannot be selected since the combo box will be empty Always first select a group and or instrument with the Select Group or Instrument button Groups and Instruments are user configurable through the configuration tool described in the Entis Pro Attention Scan Installation Guide part no 4416387 Honeywell Enraf Attention Scan Instruction Manual g 2 1 3 Display Scaling To create readability from great distance the Attention Scan application supports scaling the a p size of the data field in two ways Either by selection of the Font directly ME or by using the Enlarge and Diminish Font buttons the appearance can be changed AttentionScan Product Level me IUPRIME DEMOGAUGE_mm v D m 1 260 Bi AttentionScan 1 0 0 0 16 50 47 r AttentionScan Product Level JA DEMO FGDS DEMO CIUPRIME DEMOGAUGE_mm m Select an Instrument to display after the group is selected first 16 51 32 Figure 8 Scaling example 2 1 4 Start a New Instance Since the Attention Scan application will show one instrument at the time it can be started multiple times This is done by clicking the Start New Instance A ution Please note that more instances mean a higher load on the field bus It could lead to low responsiveness or i timeout errors Using many instances defeats the purpose of the application since this will degrade the overall performance Honeywell Enraf
9. n PC and CIU and or CRC ERROR Serial message checksum CIU field lines Check cable shielding Instrument does not respond Check addressing and or serial Connections TIMEOUT ERROR Communication time out between PC and CIU and or CIU field lines 1 On protocol level this occurs Possible problem with network interface or when a reply cannot be unscheduled disconnect Check network converted to a valid message connection routing 2 Occurs also when PARSING ERROR client server XML message fails Noise or instability Check Serial SERIALPORT_PARIT Occurs when serial port parity Connections between PC and CIU and or Y ERROR fails CIU field lines Check cable shielding Noise or instability Check Serial Connections between PC and CIU and or CHECKSUM ERROR Serial message checksum CIU field lines Check cable shielding Noise or instability Check Serial tec canon sommenarectetam Connections between PC and CIU and or LRC ERROR Serial message checksum CIU field lines Check cabre shielding OPEN ERROR device request 2 or more times other application that uses the serial port 1 Occurs when sending a Possible double use of serial port Check for request while the device is other application that uses the serial port closed DEVICE ALREADY C 2 Occurs when sending close LOSED ERROR device request 2 or more times DEVICE ALREADY _ Possible double use of serial port Check for OPENED BY NON E other application that uses the serial port
10. on can be started through the Start Menu under Entis Pro amp Enraf d Entis Pro jer RemoteViewer Documents d AttentionScan a AttentionScan Computer a Configure AttentionScan pm InstallShield Control Panel di Intel i LANDesk Management di Maintenance l Help and Support Devices and Printers Figure 2 Windows Start Menu When clicked the Main Screen is shown r AttentionScan Product Level PING Figure 3 Attention Scan main dialog Since there is no Instrument or Gauge selected yet a blank display shown Honeywell Enraf Attention Scan Instruction Manual 5 2 1 Controls These are the controls to use the Attention Scan application Select Group or Instrument Select Instrument Start a new instance Help Font settings AttentonScan 1 0 0 0 Not W amp M approved Application Status Watchdog LED Time indication Figure 4 Attention Scan main dialog controls In the following paragraphs each control is described separately Honeywell Enraf Attention Scan Instruction Manual 6 2 1 1 Select Group or Instrument Instruments are gathered in groups to create a structure The Select Group or Instrument button will start a new dialog to enable the user to either select a group or an instrument in a group Instrument Selector DEMO EGDS DEMO CIUPRIME DEMOGAUGE mm DEMO EGDS DEMO CIUPRIME DEMOGAUGE mm10 Figure 5 Group or Instrument Selector dialog The picture show
11. s several Instruments which are a member of the ALL group By selecting the group ALL the Select Instrument combo box is filled with all instruments from ALL group In this case these are DEMOGAUGE_mm DEMOGAUGE mm10 TK 01 TK03 AttentionScan Product Level EAG ma ENE DEMO EGDS DEMO CIUPRIME DEMOGAUGE mm DEMO EGDS DEMG CIUPRIME DEMOGAUGE mm10 Figure 6 Select Instrument Combo box Honeywell Enraf Attention Scan Instruction Manual 7 If an Instrument is selected directly from the Instrument Selector for example DEMOGAUGE mm the Select Instrument combo box is still filled with all instruments from the group of the selected instrument in this case ALL but additionally the instrument is selected directly AttentionScan Product Level an Lae A F E VA 5 IUPRIME DEMOGAUGE mm 3 2 m 1260 D AttentionScan 4 0 0 0 16 50 42 Figure 7 Select Instrument Combo box prefilled 2 1 2 Select Instrument DEMOGAUGE mm f The Select Instrument combo box is used to select an instrument from the previous selected group with Select Group or Instrument button by clicking the down arrow symbol The Select Instrument Selector will be empty initially because it will be filled with the instrument list from the selected group from the select group instrument function Refer to paragraph 2 1 1 If the group is not selected yet the
Download Pdf Manuals
Related Search
Related Contents
- Krups HP Color LaserJet 2605, 2605dn, 2605dtn Service Manual AudioSonic CD-1572 CD radio Canon Online-Handbuch - iP7200 series brochure Magnavox AZ6836 Owner's Manual Leslie #3300 Owner`s Manual NV-N50 - Panasonic 21g 64g 4g - STARTPRO Tecumseh RKA5512EXA Drawing Data Copyright © All rights reserved.