Home
What`s new v6.3.3
Contents
1. Change Log July 2010 Prodys PROCESAMIENTO DIGITAI INDEX New Automatic Jitter Buffer sssssessssssseessssseessssscessssscesssseeeesse 4 Enhanced N k redundancy protocol ssesesssesscsscsecssesscoscosessessessees 5 Shorter Time Between Packets for PCM and SIP ceceeeeee ee eee eee eeeees 5 Bandwidth and Overhead information including FEC info cee eee 6 ProntoNet Model and Version in SIP s User Agent field cece cece ee eee 7 New RTP automatic connection ssssssssesssesssoesesesseesesosssossseeseeess 7 PCM 20 bits 32 Khz in V4 protocol essesesssessesscssesscsscsscsscsscsseosess 9 New user configurable alarm description sssssssessessesscoscssesscssessees 9 Alarm warning on the front panel display cece ee eeeeeeeeeeeeeeeees 10 SDK available in portable units ssssessessessessessesscsscsscssesscsseesees 10 New SDK comMandS sssssrsessreisieseinsisetsnenssesriaisieneiess nsa seisieisinosi ane 11 New alarm event to notify unsuccessful scheduled Calls cce cece ee ees 11 LOOP activation and test tones cc cceccc cece cece cece cece cece eee eeeeeeeeeeeeeees 12 Ethernet port configuration on the front panel and web page 6 12 Some parameters can be changed when lines are connected 06 13 New numeric keypad on the dial window of the web page ceeeeeeees 14 Apt X at high bit
2. Voltage Out Of Range Backup O Voltage Out Of Range 3 3v System O Voltage Out Of Range 5v System O Temperature Out Of Range O Fan Failure Connection O LAN Not Present O LAN Traffic O ISDN Not Present O X21 Not Present O Line Disconnected Device Backup Active Device Backup Failed Scheduled Call Failed O Audio O No Audio Level Detected O Decoder Framed Lost O Decoder Not Framed O Backup O Backup Active O System O General O System Power Down Custom Description la 2b 3c 4d 5e 6f 7g 8h gi 10 Linea Desconectada Backup de equipos Activ Error en backup Sin Audio Sincronizaci n Perdida Sin Sincronizaci n 17p sorone Major Maj na Major Major Minor Properties Critical Major Critical Critical Critical Critical Critical Critical v Major Major Major Major Major Major Here follows the conditions that would raise this new alarm event Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com b Page 11 The scheduled call did not succeed A higher priority call was already in progress so it could not be established Itis not possible to set the network link defined for the call Itis not possible to select the compression mode defined for the call The column Value on the alarm log window will show which of the reasons above triggered the alarm new Loop activ
3. rates with double IP mode ccc cece eeeeeeeeeeeeees 14 Disconnection reason on the Call Log cece cece cece cece cece eee eeeeeeees 14 Possibility of ignoring IP remote disconnection orders ceccce cece ee ees 15 Auxiliary data at 19200 bpS ssessessesssssesscsscsscsscssesscssesscssesseose 15 New battery charge information on the front panel display 4 16 New menu layout on the Nomada IP and Nomada IP XL eceee cece ees 17 Call Log remains at the web when accessed via ProdysControl 6 17 New GPO option on Nomada IP and Nomada IP XL cceecc cece cece eee eees 17 Enhanced STUN Protocol ossuscusscanesnseganiaaticasnesesiavkesstinnncseeanneauseams 18 SIP Automatic disconnection sssssssssesesssseeessssecessseccessseceessseee 18 Model and firmware version on the user agent SIP field 00088 18 Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com b O Page 2 Accessing ProdysControl phone book and Windows 2000 0000008 18 3G ACCESS with roaming cece cece cece cece eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 19 The inverted parameter for Layer III on ISDN is available on the front panel MEDU lt scicascvdausas candesderads Ea ee E EDENE DEE TEETE EEEE ENEE EEEE 19 Wrong Vu Meter values via the SDK commandS ssessesseseessesseseess 19 I
4. O is available on Nomada IP and Nomada IP XL This option will activate a GPO when one of the mic line inputs was enabled and connected to the main line or PGR channel This option is called MIC LINE Input On Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com eee Page 17 New Enhanced STUN Protocol STUN Protocol The STUN protocol has been enhanced to achieve NAT traversal techniques STUN protocol was used in previous version just to get the public IP address when calling through a NAT device such as a router From this version onwards it has been used to get the ports used by the NAT device allowing the unit to establish IP connections through routers with no configuration as long as the router is not a symmetric NAT one this is a well know limitation of this protocol to achieve NAT traversal Ask to support prodys net for more information new SIP Automatic disconnection Automatic disconnection with SIP protocol Given that SIP does not define a way to detect that the audio connection dropped some different techniques can be used to do it We have adopted the most common one in this version if the decoder loses framing for at least 30 seconds the unit drops the line to inform the customer about such a situation Model and firmware version on the user agent SIP field The User Agent field of SIP protocol frames ind
5. SDN audio mode selection on the front panel sssssesessecsscsscssessess 19 Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Cc SE eee O Page 3 Date 01 07 2010 Version V6 3 3 Mew New Automatic Jitter Buffer From this version onwards it is possible to configure the jitter buffer to adjust itself automatically to the jitter of the network As it can be seen in the picture below when configuring the buffer to Auto a maximum value for the buffer might be defined in order to prevent the buffer from growing beyond a maximum delay level Codec 1 Configuration User Line Delay z V Max Delay PIRA Timedate S Password Manual buffer adjustment A Aux Data r Ii Version a j Alarms B Net Backup Device Backup i edi Bandwidth Limit Book 42 Scheduler gp Advanced 4 Streaming off Protocol Export Import Restore Default When the buffer is configured to adjust automatically to the jitter of the network this buffer will grow every time the measured jitter of network goes beyond the jitter buffer value till it reaches the maximum value when defined Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Cl eee OOO Page 4 The other option is to config
6. al O Scheduled Call Failed Audio O No Audio Level Detected Major Pa Decoder Framed Lost I 2 sido Fang on oo EE O Decoder Not Framed Major O Backup O Backup Active Major System General Major Z System Power Down Major Fe A In the following picture it can be seen how this description appears in a new column of the alarm log called Custom Description Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com eee SS Page 9 Alarms History C Enable Fiter Configure Alarm Category Active Seve Init Time End Time Value Custom Description Check all O Decoder 1 Framed Lost Audio No Major 22 03 2010 2 1 22 03 2010 2 10 55 PM Line 1 Framed Lost The audio framing got lost O Decoder 1 Framed Lost Audio No Major 22 03 2010 2 1 22 03 2010 2 12 00 PM Line 1 Framed Lost The audio framing got lost O Decoder 1 Framed Lost Audio No Major 22 03 2010 2 1 22 03 2010 2 18 45 PM Line 1 Framed Lost The audio framing got lost Report New Alarm warning on the front panel display From this version onwards when an alarm is still active this warning message will be shown on the front panel display HH EHH ALARM HHEHH ACTIVE An alarm event is still active when the condition that raised the alarm remains An alarm event is not checked when the alarm event finished meaning that the condition that activated the alarm is gone
7. ation and test tones This version includes a Test option in the audio configuration menu that permits loop activation and input and output test tone generation Loop activation is no longer located in the Sys menu New Ethernet port configuration on the front panel and web page With this new version the Ethernet port configuration can be checked both on the front panel menu in the INF gt LAN option and on the web page under the Ethernet port tab in the Configuration window Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com EES O Page 12 Configuration i Ethernet Port Configuration ae LAN Speed Current B 43 Interfaces z an VLAN 100 Full Duplex autonego Autonegotiation Modes 10 Half Duplex 10 Full Duplex 100 Half Duplex m Ra m m 4 i GPIO 10Half Duplex Audio 10 Full Duplex of Audio 100 Half Duplex pa 5 say La 100 Full Duplex i Timedate a Device Backup Export Import Restore Default 9 License gE Beneath Limi P Cancel Apply This information is specially helpful when configuring the Ethernet port to Auto mode New Some parameters can be changed when lines are connected In previous versions it was not possible to change some configuration variables when either one
8. but the alarm was not checked on the alarm log by the user In this situation no message will appear in the front panel display This new warning message on the front panel display will alternate with the main information window every few seconds Of course once the user enters the main menu this information will not appear till the user goes out from the menu or the user stop using it for some seconds This information will not appear only in the case the user has entered the information window by pressing the INF key on the front panel keypad This warning message will not appear in the Nomada IP and Nomada IP XL displays mew SDK available in portable units From this version on SDK commands can be used in all Prodys portable units PortaNet Nomada IP and Nomada IP XL Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Cae SE Page 10 _ New New SDK commands Some new SDK commands are available For more information about this please refer to the latest version of SDK User Manual available on the download section of Prodys web page along with this document New New alarm event to notify unsuccessful scheduled calls This new alarm event is called Scheduled Call failed and it was included in the connection section in the alarm configuration window Alarm O Monitor O Voltage Out Of Range Main O
9. he connection was dropped locally Manually disconnected The connection was terminated at the remote end Remotely disconnected The connection finished because a line drop Connection dropped New Possibility of ignoring IP remote disconnection orders A new option has been included in advanced options IP Ignore Remote Disconnect Request New Auxiliary data at 19200 bps The auxiliary data port has been modified to reach 14400 19200 38400 57600 and 115200 bps with the condition that the port at that velocity works with short data bursts and that the average speed doesn t exceed 9600 bps Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Pa SE Page 15 _ PA Co nfiguration 5 4 Interfaces RS232 Config gt aun RS232 Speed Line 1 115200 bps 38400 bps v G Control VLAN Audio VLAN Ports This setting only specifies the maximum physical value i F7 SNMP NOT the actual amount of ancillary data sent inside the LEP Ethernet Port audio data stream EE Sy ISDN Net i BA Line 1 L bA Line 2 Timedate SB Password A Aux Data Version Alarms Netw i Device Backup i A License new New battery charge information on the front panel display In the Nomada units the remaining time of battery charge is indicated on the front panel displa
10. icates now the product model and firmware version Example User Agent ProntoNet v6 3 3 Fix Accessing ProdysControl phone book and Windows 2000 This problem rarely appears on computers with Windows 2000 as operating system The problem appears when accessing the DIAL window via the ProdysControl software on one unit and selecting the Phone book tab Depending on the contents of the phone book ProdysControl Client application might freeze when accessing the phone book Even though this problem depends on the operating system and only appears on Windows 2000 it was fixed changing the way of access to the phone Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com eee SE Page 18 book on the OCX of the web page that is also used by ProdysControl to display the user interface ia 3G access with roaming When the SIM card used to access the 3G network was enabled for roaming and the roaming service was in use there were some problems to access and register with the provider Fix The inverted parameter for Layer III on ISDN is available on the front panel menu From this version onwards the inverted parameter for Layer III when sending audio over ISDN is also available on the front panel menu This parameter should be checked normally to assure compatibility with most of major manufacturers For more information abo
11. imit amp Book Bandwidth OverHead HE Scheduler nye gt a Aesaad Packet Size Min Audio Delay SE a i Multicast n Beas i Bandwidth OverHead MEE ay TX Packet Size Min Audio Delay 10 ms HG es MEA B Codec 2 RIP GRR fe Codec 1 Codec 2 Restore Default B Test New Bandwidth and Overhead information including FEC info The information about the required bandwidth and the overhead can be configured now to include information about the FEC mechanism Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com __ Page 6 A Configuration x2 IE Codec 1 Configuration gF RS232 GPIO Time Between Packets gE Audo Algorithm PCM z Ql Audio Sy Sys id Sys Timedate Password Aux Data Version amp Alarms Algorithm USERS TSM bps 48Khz 16 bits Mono Net Backup Device Backup Time Between Packets Packets per Second 9 License f Bandwidth Limit dites Book Bandwidth MEMES OverHeac MA Schedul a S S coe Packet Size MEMES Min Audio Delay lt q Streaming Multicast 4 Protocol f Profles Bandwidth ERAS OveHea EEA Packet Size BREA Min Audio Delay 4 As it can be seen in the picture above the user can get information about the overall bandwidth requirements audio FEC or just the requirements for either the audio or the FEC mechanisms individually Naw Pron
12. line or both of them were connected Now it is possible to access and make changes on the following sections of the configuration menu even thought either one or both lines are connected 1 It is possible to enter the ISDN configuration if the selected audio interface is not ISDN 2 The time and date configuration window is now accessible when lines are connected 3 The alarms configuration window is also accessible 4 Net BackUp configuration window can be configured while lines are Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com CC eee Sy Page 13 connected PEN New numeric keypad on the dial window of the web page A new numeric keypad is available at the Dial window of the web page to enter the destination address without the need of a physical keypad This is quite useful for those users that do not use a keypad but only the mouse to control their applications EZ DIAL BE Call Net Er Codec 1 Audio Mode MPEG L2 64kbps 48khz Mono Tx 83 3 3 3 Phone Book IP Phone Book ISDN Discover En Name IP Audio Mode To open the numeric keypad just click on the green keypad icon at the right side of the text box to enter the destination address Call Type Unicast Bidirectional v Target Codec 1 v Target Codec REW Apt X at high bit rates with double IP mode In previous versio
13. ns apt X was limited to 64kbps on the second line for IP connections From this version onwards it is possible to configure the encoder of line 2 at a bit rate of 128 kbps with apt X compression mode New Disconnection reason on the Call Log The disconnection reason is included in the Call Log This way the user can know the reason why any of the registered calls was terminated In case of an ISDN call the disconnection reason will be notified as a code A table with the disconnection Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com aa SE Page 14 _ codes for ISDN calls is available on the Prodys IP Family User Manual End Time Duration Disconnect Reason J 10 40 53 4M 23 03 2010 10 40 55 4M Od 00 00 02 16 J 10 40 53 AM 23 03 2010 10 40 55 AM Od 00 00 02 16 J 10 28 58 AM 23 03 2010 10 36 51 AM Od 00 07 53 Manually Disconnected J 4 41 06 PM 22 03 2010 4 45 59 PM Od 00 04 53 Manually Disconnected J 4 29 33 PM 22 03 2010 4 35 23 PM Od 00 05 50 Remotely Disconnected In this example we have two ISDN calls first two calls ended with termination code 16 meaning that the call was terminated normally by either of the two ends Below these two calls we have three IP connections One of them was terminated at the remote end and the other two calls were terminated locally In case of an IP connections there are three disconnection reasons T
14. tically but the word Stopped appears on the Decoder This is an indication that the unit is waiting to receive the incoming data When the first packets aimed at the specified port are received the word Stopped will change to Searching first and when the audio gets framed the audio configuration will be shown If the connection is lost the word Stopped will be shown again waiting for the reception of a new call Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com Page 8 New PCM 20 bits 32 Khz in V4 protocol V4 protocol permits now the coding of PCM using 20 bits and 32 KHz new New user configurable alarm description The user can enter a custom description for each alarm event This description will appear on the alarm log on a new column called Custom Description Please take a look at the picture below illustrating how to assign the sentence Audio framing got lost to the Decoder Frame lost alarm Alarm Value Custom Description Severity A O Voltage Out Of Range 3 3v System Major O Voltage Out Of Range 5v System Major O Temperature Out Of Range Major 3 O Fan Failure Minor Connection Popas LAN Not Present Critical O LAN Traffic Major O ISDN Not Present Critical O X21 Not Present Critical O Line Disconnected Critical O Device Backup Active Critical O Device Backup Failed Critic
15. toNet Model and Version in SIP s User Agent field SIP s User Agent field contains now information about which ProntoNet model generates the IP traffic Information about firmware version is also included in that field New New RTP automatic connection In the RTP configuration menu a new automatic answering mode compatible with Mayah and Luci has been implemented In this mode the unit is constantly scanning the RTP port and when incoming traffic is detected from another codec connects to this codec using the same audio configuration Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com cll Be OO Page 7 oft HP2 P OVE i HPS Q baj ine Streaming Protocol RIP a Ly v Test Configuration a Sys Local Port 5004 0 Timedate Automatic Answer Mode 8B Password Streaming will start automatically when incomming streams detected Version RTP Compatibility Ae Normative According to the standard for IP compatibility defined bi Normative According to the standard for IP compatibility define c y ee mi by the EBU group N ACIP La cca en gt Luci compatible mode he andwidth Linn j si i APT compatible mode a cheduler d g O Mayah compatible mode peu ie Profiles q S ir TX J ops 2 ay This new automatic mode works as follows after clicking on the connection bar Tx and Rx connect automa
16. ure the buffer manually as it was prior to this new version New Enhanced N k redundancy protocol This version supports an enhanced version of the Prodys N 1 Redundancy Protocol For more information about this please refer to the document Prodys Reliable Configurations pdf available on the Support Documents in the download section of Prodys Web Page a Shorter Time Between Packets for PCM and SIP In prior versions when the unit was configured to work with SIP protocol the audio mode was set to PCM and the FEC option was activated the shorter value for the Time Between Packets parameter was 5msc which caused packet fragmentation Now it is possible to set the Time Between Packets parameter to 4msc with the same configuration detailed above in order to avoid packet fragmentation Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com E O O Page 5 P Configuration EA Codec 1 Configuration RS232 GPO GPIO Time Between Packets audo Algorithm PCM x j Audio Ay Sys A I Sys a E late Timedate Bandwidth Usage SB Password amp Aux Data Type Audio FEC Version amp Alams Algorithm PCM 2304Kbps 48Khe 24 bits ST Net Backup a Backup Time Between Packets EI Packets per Second 375 9 License i ase Unicast OB Bandwidth L
17. ut this and ISDN compatibility in general please download the file ISDN Compatibility zip at the Support Document area in the download section of Prodys Web Page Fix Wrong Vu Meter values via the SDK commands The VU Meter values obtained via the SDK protocol were not correct nix ISDN audio mode selection on the front panel When the second line was connected on ISDN it was not possible to select any compression mode other than G711 on line 1 This issue has been fixed in this version Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com SS Page 19 _
18. y by pressing the INF key This time indication is an estimation based on the battery charge Prodys S L Tel 34 91 6896880 Fax 34 91 6943777 Email sales prodys net Web www prodys com ll Sa Page 16 New New menu layout on the Nomada IP and Nomada IP XL The main menu layout was changed on Nomada IP and Nomada IP XL units to ease access to the audio and presets options These two options are supposed to be accessed more often than any other so they have been moved to the top of the menu so that non experienced users might find them more easily The menu layout was changed so that the fist menu will be the following N O M A DIA M E NJ U A U D IT O P R JEJ JS E TIS MIEINJU Under the MENU option the user will find the rest of options as they were in previous versions New Call Log remains at the web when accessed via ProdysControl From this version onwards when the unit is being controlled via ProdysControl the call log entries remain accessible via the web interface In previous versions once the unit was accessed via ProdysControl the entries of the call log were removed and stored on the ProdysContol database This behaviour has been changed so that they remain available via the web page New New GPO option on Nomada IP and Nomada IP XL A new option to enable a GP
Download Pdf Manuals