1. 12 12 Declaration Conformity atv Page 13 R ESPINAR S L IDi 03 DESCRIPTION Control Panel INCUTERM DIGIT 1 Main switch When switching it on 1 it activates all the circuits of the oven 2 Safety thermostat Hydraulic safety thermostat class 3 1 it assumes the functions of temperature control in the case of failure of the main regulator 3 Thermostat handle immobilizing device Turning it clockwise immobilizes the thermostat handle to avoid involuntary displacements Turning it anti clockwise unblocks the thermostat handle allowing to turn freely the button Safety thermostat pilot light It lights when the Safety Thermostat works 5 Temperature and time microprocessor s controller see specific instructions for its use TECHNICAL SPECIFICATIONS Apparatus Bacteriological and culture oven Temperature range from 5 C to 80 C Temperature homogeneity 2 Temperature stability 0 2 Feeding voltage 115 230 V according to characteristics plate Net frequency 50 60 Hz Order error 2 at work temperature Resolution 0 1 3 13 R ESPINAR S L IDi 03 Modelo ID 20 ID 40 ID 50 ID 90 ID 150 ID 288 W 160 260 260 400 900 1000 CHARACTERISTICS Inside frame double chamber and inner door in stainless steel AIS
2. R ESPINAR S L 1Di O3 TRADE e 5 R ESPINAR S L a mn INSTRUCTION MANUAL FOR USE AND MAINTENANCE BACTERIOLOGICAL AND CULTURE INCUBATORS INCUTERM Models ID 20 ID 40 ID 50 ID 90 ID 150 ID 288 1 13 R ESPINAR S L IDi 03 A It is very important to keep these instructions with the apparatus in case of doubt of use If this apparatus should be sold or transferred ensure that this manual is given to the new owner for correct use and understanding of the apparatus This manual has been written for safety reasons read the instructions carefully before installing and use of this apparatus INDEX Description rsa ue tah a iets aca Page 3 Technical 3 4 ACCOSSOMOS 15 5 4 Install ei nn Page 5 Connection to the MAINS ooooocccccnnccnocococcncnnonanonononcnnannn Page 5 Microprocessor s description 6 FUNCTION ii 7 Functioning type 8 Start p INSTUCHONS adri Page 9 10 Satety thermostat omer o 5 10 Load distribution 11 Cleaning A 11 Reparation and Spare parts
3. 3 MAINTENANCE OF THE PROGRAMMED TEMPERATURE TIME TYPE a time can be programmed maintain the programmed temperature during this programmed time After passing it the equipment stops 4 WAITING TIME MAINTAINING TIME AND TEMPERATURE PROGRAMMED TYPE a waiting time can be programmed when switching on a work temperature a maintenance of programmed temperature time and stop the equipment Whichever of these types can be programmed by interest of the user 7113 R ESPINAR S L IDi 03 FUNCTIONING TYPE EDITION The main switch 1 of the equipment must be activated and the temperature s control off RUN pilot put out to edit the selected values of temperature waiting time and maintenance of temperature time To put out the RUN pilot press the START STOP key along one second Order temperature s programming press the thermometer key to enter in the edition of the temperature s order The pilot thermometer will light up intermittently and in the display will appear the selected value To modity it press the UP and DOWN keys until the wanted value in grades appear The edition boundaries depend on the scale depth If the order value has been modified it will appear twinkling To keep the modified value we will press again the thermometer key and we will go back to the initial situation lf we want to leave the order edition without keeping the modified value we will press the clock key the start stop key or we
4. 50082 1 R Espinar S L Av del Vall s 322 P I Els Bellots 08227 TERRASSA Barcelona SPAIN Tel 93 783 03 44 93 783 07 20 FAX 93 731 37 17 Web site http www cecot es raypa E mail raypa cecot es 13 13
5. will let pass 10 seconds time Delayed starting time programming press the clock key twice in a row to enter in the waiting time edition The timer pilot will light up intermittently and in the display will appear the programmed value To modify it press the UP and DOW_N keys until the wanted value will appear The boundaries of edition are compressed between 0 00 and 99 5 hours If its value has been modified it will appear twinkling To keep the modified value we will press the clock key once again and we will go back to the initial situation To leave the edition without keeping the modified value we will press the thermometer key the START STOP key or we will let pass 10 seconds time Maintenance time programming press the clock key once to enter in the maintenance time edition The clock pilot will light up intermittently and in the display will appear the programmed value lt works as the Delayed starting time programming But its edition boundaries are compressed between OFF 0 00 and 99 5 hours If the selected value is OFF the regulation will be done for an indefinite time and it will stop only if we stop the regulation pressing the start key 8 13 R ESPINAR S L IDi 03 When the control is on the RUN pilot lighted if we press the thermometer key the temperature order programmed will be showed lf the value is modified and kept it will only be operative during this execution because when finishing the execu
6. I 304 DIN 1 4301 Outside frame oven painted with epoxi resin Elastic joint of silicone Perforated trays in stainless steel AISI 304 DIN 1 4301 height adjustable with a device to remove the trays without overturning them Interior VIDUR glass door with magnetic shutting Adjustable ventilation device Digital temperature control and reading by microprocessor Heating by large surface heating elements placed at independent chamber that allows an optimum temperature stabilization ACCESSORIES Accessories that must be installed in the factory Ref Description BE 20 Stainless steel perforated tray AISI 304 Can be used up to 5 units in ovens ID 20 BE 40 Stainless steel perforated tray AISI 304 Can be used up to 7 trays in ovens 10 40 BE 50 Stainless steel perforated tray AISI 304 Can be used up to 6 trays in ovens ID 50 BE 90 Stainless steel perforated tray AISI 304 Can be used up to 9 trays in ovens ID 90 BE 150 Stainless steel perforated tray AISI 304 Can be used up to 9 trays in ovens ID 150 4 13 R ESPINAR S L IDi 03 BE 288 Stainless steel perforated tray AISI 304 Can be used up to 14 trays in ovens ID 288 A INSTALLATION Place the oven on a solid surface Don t install the oven in areas where there is danger of fire or explosion The oven is not fire proof for this reason it is not appropriate for drying evaporating baking enamel or similar substances which contain solvents that cou
7. e the oven If that happens the oven must be immediately cleaned and polished 11 13 R ESPINAR S L IDi 03 REPARATION AND SPARE PARTS Before any reparation disconnect the apparatus from the mains Please get in touch with your distributor if in doubt For safety reasons and a good function of the apparatus use original spare parts only If spare parts are needed state the serial number and the model of the apparatus indicated on the characteristic plate at the rear of the apparatus A GUARANTEES This equipment is guaranteed for a year against any manufacturing failure or faulty piece The guarantee doesn t cover damages produced by improper uses or by alien causes to R Espinar S L Any manipulation done by personnel non authorized by means of R Espinar S L automatically cancels this guarantee The guarantee and claims are excluded if these instructions are not followed R Espinar S L reserves all right to change technical specifications 12 13 R ESPINAR S L IDi 03 DECLARATION OF CONFORMITY The manufacturer Espinar S L Declares under its own responsibility that the apparatus Culture and Biological Ovens INCUTERM Models ID 20 ID 40 ID 50 ID 90 ID 150 and ID 288 It fulfils with the directives of security 73 23 CEE Low tension 89 336 CEE Electromagnetic Compatibility Beyond International Rules EN 61010 1 EN 61010 2 010 EN 50081 2 EN
8. f a maintaining time has been programmed when the temperature reaches the programmed value the red pilot will light up and the maintaining time will start to countdown Once it has past the regulation will stop and the RUN and clock pilots will put out If a maintaining time OFF has been programmed the clock pilot will remain always on 9 13 R ESPINAR S L Raups IDi 03 To stop the regulation manually we will do the same as for the starting we will press along 1 second the START STOP key NOTE in the first starting it is possible that the temperature overtakes in some grades the ordered temperature After some time the temperature will decrease once stabilised proceed to load the oven procuring to have the door closed the maximum possible time If in the control system exists an order error of 2 at working temperature increase the order in the same value as the value of the error detected because the real temperature of the oven is the one indicated in the microprocessor s display For example if a temperature of 37 has been programmed and once the temperature has stabilised it remains in 36 72C increase the order to 37 3 and thus the real temperature will be 37 indicated in the display SHUT DOWN Put the main switch 1 to the O position SAFETY THERMOSTAT Temperature s adjustment of the shooting of the safety thermostat 1 Displace the safety thermosta s handle 10 above the worki
9. ld burn or explode CONNECTION TO THE MAINS There is the characteristics plate situated at the rear indicating the voltage and power Check to make sure that your electrical installations have the same conditions The plug of the oven is a SCHUKO with central and lateral connection for security reasons the oven must be installed to ground 5 13 R ESPINAR S L IDi 03 MICROPROCESSOR S DESCRIPTION 6 13 R ESPINAR S L IDi 03 6 START STOP KEY key to start or to stop the execution program It is also to leave the edition of the orders or variables of configuration without keeping the modified value 7 UP KEY key to increase the values of the variables of edition and configuration 8 DOWN KEY key to decrease the values of the variables of edition and configuration 9 THERMOMETER KEY key to enter in the edition of the order of temperature and configuration parameters 10 CLOCK KEY key to enter in the edition of the waiting time and execution and to edit the configuration parameters FUNCTION TYPES The equipment can work in four different types 1 NORMAL TYPE the equipment will work only with a temperature maintenance and during an indefinite time 2 DELAYED STARTING TYPE work temperature and delay in the connection of the equipment to execute the selected program can be programmed and it will be executed automatically after passing the delayed time programmed
10. ng temperature 2 Start up the oven with the door open switching on the main switch 3 Turn slowly the safety thermostat s handle anti clockwise when the temperature is stabilised in the prefixed temperature until the characteristic acoustic sound is heard and the red pilot lights After that turn slowly the button clockwise keeping the rearm button pressed until the red pilot puts out Thus the safety thermostat remains fixed in 1 or 2 C above the working temperature Always when working at different temperatures the same operation must be realised 10 13 R ESPINAR S L IDi 03 LOAD DISTRIBUTION To use correctly the machine and for a homogeneous temperature distribution it is essential to keep in the inside of the oven a good air ventilation Therefore the object put in the oven must be placed leaving some space for the air circulation Do not put any load over the oven s floor at least over the first tray Do not place any load too close to the roof or walls of the oven put it at least at 3 cm distance CLEANING Cleaning regularly the oven keeps the equipment in good conditions of use The residuum in the oven must be cleaned they can change oven functions The frame and the inner door may be cleaned with any stainless steel cleaning product The outside of the frame can be cleaned with polishing liquids with silicone Some products or the steam that they produce can cause corrosive spots insid
11. tion the regulator recovers the order value programmed when the program was not on If the control is on RUN pilot lighted and at this moment the control is executing the waiting time at pressing twice the clock key the remaining waiting time value will be visualised If the clock key is pressed only once the maintaining time programmed will be visualised But if the control is executing the maintaining time the waiting time will not be visualised If any of these two values is modified and kept it will only be operative during this execution because at finishing it the regulator recovers the value programmed when the program was not on START UP INSTRUCTIONS Connect the oven to the mains Press the main switch 1 and it will light After passing some seconds the microprocessor s display will indicate the eguipmen s temperature If a working temperature waiting time or maintenance temperature time has been programmed press the START STOP key along 1 second and the RUN pilot will light up starting the programmed cycle Once the temperature is reached the thermometer pilot will make some light up light down cycles keeping the programmed temperature If a delayed starting time has been programmed while being executed the waiting time the TIMER pilot will be lighted up At finishing the time the TIMER pilot and the controller will put down and the regulation will start to bring the temperature to the programmed order I

Download Pdf Manuals