Home

GSM-1000

image

Contents

1. www elsema com GSM Receiver with relay output GSM 1000 Application GSM 1000 12V AC DC application GSM 1000 240VAC application 240VAC Supply ID B TALITA Page 9 www elsema com GSM Receiver with relay output GSM 1000 Notes Authorised Numbers Position Phone Number Name 1 Se an ny A N p p en pi N pi Ge pi EN pi un pi pi N p oe pi D N pi N N N W N A N un D N N N N ee N U p Ge D Page 10 www elsema com GSM Receiver with relay output GSM 1000 Authorised Numbers Position Phone Number Name 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Page 11 www elsema com
2. E g The following number 0435792468 is to be setup as the first user the following SMS command is needed 1234 TEL0435792468 01 The authorised numbers are mobile numbers of all users who will be using their phones to operate the GSM 1000 e g If installed on a gate at home then all family member s mobile number Serial number is the position of all stored numbers authorised users 1 64 users It is strongly recommended that the first 2 numbers are mobile numbers not landline If inputs 1 amp 2 are used and is activated an SMS message will be only sent to the first 2 stored numbers serial numbers 01 amp 02 e Check which mobile number is located at a particular location Serial number o Pwd TEL Serial number E g If the user wants to see which number is stored on position 2 serial number 02 the following SMS command is needed 1234 TEL02 e Delete a user o Pwd TEL Serial number E g A user on position 13 serial number 13 has to be deleted from the user list the following SMS command is needed 1234 TEL 13 It is recommended to keep a list of all users and their numbers position If a new number is programmed on a location which already has a number stored the old number will be deleted and the new number is stored e Disable Digital Inputs Inputs are disabled as factory default o Pwd DA Page 4 www elsema com GSM Receiver with relay output GSM 1000 In order to use the digital inputs
3. it has to be enabled e Enable Digital Inputs Inputs are disabled as factory default o Pwd EA When the inputs are enabled the sensors will be armed after 10mins from the last received call If the sensors are triggered within the first 10mins these signals will be ignored After 10min when the sensors are active and if they are activated Relay 2 will switch ON a siren or warning light can be connected and a programmed SMS message will be sent to the first 2 numbers programmed serial number 01 amp 02 e Alarm inputs status ON or OFF o Pwd AL In order to check if the digital inputs are enabled or disabled the following SMS command is needed 1234 AL Reply SMS will be one of the following Alarm Inputs Disabled or Alarm Inputs Enabled e Allow access to all numbers calling the GSM 1000 o Pwd AA To allow access to anyone making a call to the GSM 1000 the following SMS command is needed Warning This will allow anyone who makes a call to operate the GSM 1000 1234 AA e Allow access only to authorised numbers calling the GSM 1000 o Pwd AU To allow access to authorised numbers only the following SMS command is needed 1234 A U This allows only the numbers that are authorised to operate the GSM 1000 This is set as factory default and is recommended for secure operation e Check authorised user s settings o Pwd AC To check if only authorised users or any number can operate the GSM 1000 the follow
4. GSM Receiver with relay output GSM 1000 GSM 1000 GSM receiver with relay output for opening sliding and swing gates and doors or switching devices Features Switches relay with free call from mobile phone Only authorised numbers can operate the GSM 1000 No call charges Operates from anywhere if GSM network is available Unlimited range Ignores unauthorised numbers Authorised numbers easily entered by SMS command 2 digital inputs for sensors or switches SMS confirmation of relay switching Secure Password protected 12 Volts DC power pack included Application Open close gates doors shutters garage doors with a free call Security alarm On Off lights pumps and machines Description The GSM 1000 works on latest GSM technology All you need is to insert a valid SIM card and program phone numbers of all users through simple SMS text commands When an authorised user makes a call to the receiver it rejects the call after a single ring and activates a relay Since the call is rejected the user is not charged for the call There are 2 digital inputs available which can be wired to motion sensor PIR door switch windows or any other type of NO normally open switch The GSM 1000 can be programmed to send different SMS messages for each input e g a reed switch from the kitchen window is wired to input 1 which will send an SMS message Kitchen Window when activated and a motion sensor PIR in you bedroom is c
5. ing SMS command is needed 1234 AC Reply SMS will be one of the following Allow all numbers cannot access it or Allow all numbers can access it Page 5 www elsema com GSM Receiver with relay output GSM 1000 e Setup Relay OFF delay o Pwd GOTtime The relay OFF delay can be set from 0 9 5sec The factory default is 0 5sec The number in the SMS command will be twice the relay OFF delay time E g If the relay OFF delay needs to be set at 5secs the following command is needed 1234 GOT10 Relay will stay ON for 5sec once activated e Check the relay OFF delay o Pwd GOT The SMS reply will tell the current setting e Change relay mode to Latching o Pwd GOT00 The relay will be set to latching mode The first call will switch ON the relay and the second call will switch OFF the relay This mode is only available to the first 3 users All other numbers will be ignored e Change Digital inputs from NO to NC Factory default is Normally Open NO o Pwd KEYNC The above SMS command will change the digital inputs from Normally Open NO to Normally Closed NC type If the input type is selected as NC type and is not used the inputs will have to be shorted out e Change Digital inputs from NC to NO o Pwd KEYNO The above SMS command will change the digital inputs from Normally Closed NC to Normally Open NO type e Check the GSM signal level o Pwd CSQ The above SMS command is used to chec
6. k the GSM network signal level the GSM 1000 is receiving The range is from 0 32 The minimum level for the GSM 1000 to work effectively is gt 12 If the signal level is too low even after connecting the antenna it is recommended to change your carrier to the one with a better coverage in that area Page 6 www elsema com GSM Receiver with relay output GSM 1000 e SMS confirmation of relay switching o Pwd R If the above feature is enabled the user will receive an SMS message every time the relay switches ON or OFF The following messages will be received The relay is ON or The relay is OFF This feature is disabled by factory default The above feature can be disabled by the following SMS command o Pwd N To check if the SMS confirmation feature is enabled the following SMS command is needed o Pwd M The following messages will be received Relay action return SMS ON or Relay action return SMS OFF e Program SMS message to be sent when input 1 or 2 is triggered o Pwd TEXT1sms message for input 2 o Pwd TEXT2sms message for input 1 This command includes double E g If the user wishes to change the factory default message for input two to kitchen window the following SMS command is needed 1234 TEXT1kitchen window The above command will store the SMS message which will be sent to 1 and 2 users when the respective inputs are triggered Maximum of 30 characters are allowed fo
7. ll If the sensors are triggered with in this 10minutes the signals will be ignored Commands must be in CAPITAL LETTERS Do not leave any space between the letters or words e g TEL is correct while tel is incorrect If the GSM 1000 is used to operate only a gate all the user has to do is to change the default password and enter the authorised numbers Keep a list of the authorised numbers for future reference If the SMS command sent to the GSM 1000 is incorrect a return SMS will be sent as follows Command error as please resend command Please check the command carefully make sure that it is in Capital letters and all characters are included If you cannot send or receive any SMS message from you phone to the GSM 1000 try adding in front of the phone numbers or the country code Page 3 www elsema com GSM Receiver with relay output GSM 1000 SMS Commands Below are the SMS commands needed for the GSM 1000 In the examples the default password is used 1234 Please replace this with your own password if you have changed it e Setup a new password o Pwd PWDnewpassword PWDnewpassword E g The default password is 1234 and it has to be changed to 8787 the SMS command needed is 1234 PWD8787 P W D8787 If your password is successfully changed the unit will send you an SMS message Password modified OK Password Changed to 8787 e Setup Authorised Numbers o Pwd TELauthorised number Serial number
8. onnected to input 2 which will send a message Bedroom when activated A 12V output is also available on the GSM 1000 which can activate a 12VDC siren or warning light when the either of the inputs are activated Refer to the wiring diagram The GSM 1000 works on GSM network therefore the receiver can be activated from anywhere in the country where GSM network is available For example you can open your gate or switch on your kitchen lights in Sydney from Melbourne by making a call from your mobile phone and without getting charged 12 Volts DC Power Pack Included Page 1 www elsema com GSM Receiver with relay output GSM 1000 Technical Data Power Source 12 Volts DC GSM Frequency 900 1800MHz Output Common C and Normally Open NO relay outputs rated at 3A 240VAC Shipping Weight 500 grams Dimensions 120 x 90 x 25 mm Safety Instruction Safe startup Do not use the GSM 1000 in places where GSM equipment is prohibited or might bring disturbance or danger Interference A Wireless equipment might interfere GSM network signals of the GSM 1000 and influence its performance Avoid using at Gas Stations Do not use GSM 1000 at a gas station Power off the unit when near fuels or chemicals EU Avoid using near blasting areas DANGER BLASTING AREA Please follow relevant restrictive regulations Avoid using the device in blasting places 7 Reasonable Use Please in
9. r each message The default message is Door Open Alarm e Reset the GSM 1000 to factory default o RESET The command RESET has to be sent within 3 minutes after the GSM is powered up A return SMS will be set to the user Reset ok after a successful reset Page 7 www elsema com GSM Receiver with relay output GSM 1000 Block Diagram cC Relay 1 NO gt Relay 2 o y p 9 WIS 42vDC Output Input 1 Input 2 ELSEMA euuswy WSO Power ON 12VDC power Led indicator Relay Status The LED lights up when either of the relay switches ON Orange flashing Searching for GSM network GSM Red Flashing Incoming call or SMS Green On Connected to the network C Common output of relay 1 Belay NO Normally Open output of relay 1 C Common output of relay 2 eee NO Normally Open output of relay 2 12VDC Output 12V DC output Can be used to connect siren or light Digital input 1 Can be used to connect Reed switch PIR or fire alarm Has to be NO Input 1 normally open type Digital input 2 Can be used to connect Reed switch PIR or fire alarm Has to be NO Input 2 normally open type 12V DC Supply Input supply Use power pack provided Relay 2 will only activate for 90sec when Input or Input 2 is activated Please check and make sure that the 12VDC supply is big enough to supply the GSM 1000 unit and the load Page 8
10. stall the product at a suitable place as described in this manual Avoid signal shielding by covering the mainframe f Maintenance FH All wiring and maintenance should be carried out only by qualified maintenance personnel Page 2 www elsema com GSM Receiver with relay output GSM 1000 Setup and Programming Instructions 1 2 3 4 10 11 12 Caller ID has to be enabled so that the GSM 1000 knows who s calling Insert the SIM card into the GSM 1000 The default password is 1234 All settings are through SMS commands please type the relevant SMS commands in your cell phone and send to the GSM 1000 controller SIM number Relay 1 switches ON for the programmed time factory default is 0 5sec for every incoming call from an authorised number If a call is made and relay 1 is On and another valid call is made before the relay switches OFF the off delay time is ignored and the relay switches OFF e g The off delay for relay 1 is set at 5 sec If a call is made and the relay is switched ON Another valid call is made 3sec after the first call relay 1 will switch OFF as soon as the second call is received Relay 2 switches ON for 90sec only when the sensors connected on Input 1 or Input 2 is triggered A programmed SMS message will also be sent to the 1 and the 2 users The function of the 2 input are the same Inputs 1 amp 2 will enter Armed mode after 10minutes from the last received ca