1. 2 s sxssrrererenienezanen 1 OVEFVIEW e earen deaan a iaa r a a aaa aaa a E aaa a a a EEE E 2 Features Eee een 2 Packingikist es ee ie 2 Hardware Description ss Physical Dimensions esse 4 2 1 1 LED lndicators u rien 4 Table 2 1 EKI 2726FHPI LED Indicators 4 RJ 45 Pin Assignments u02 een eis 5 InstallatiON s s s0sssssseenenezenenea 7 DIN RAIL MOUNDIN esso E N 8 3 1 1 Assembling the DIN Rail Clip 8 Figure 3 1 Rear side of the Switch 8 3 1 2 Hanging the Industrial Switch nerssssnnnenssnnnnnnnnnennnnnnnnnn 9 wall Mounting sii ee 10 Grounding the Industrial Switch 11 Wiring the Power Inputs anne 11 Figure 3 2 Plugs for Power 1 amp Power 2 11 Figure 3 3 Captive Screws for Fixing WireS 12 Wiring the Fault Alarm Contacts 12 Figure 3 4 Terminal Block Plugs for Fault Alarm Contacts 12 Figure 3 5 Fault Alarm Wiring Example 12 Ethernet Cabling scinni taa aaraa pngna ee 13 3 6 1 Connecting the SFP Port 13 Figure 3 6 Transceiver to the SFP slot 13 Figure 3 7 Transceiver Inserted 13 Figure 3 8 LC connected to the transceiver 14 3 6 2 Disconnecting the SFP Portt 14 Figure 3 9 Remove LC connector ii 14 Figure 3 10Pull out from the SFP slot 14 Troublesh
2. 3 TD 3 RD 6 TD 06 RD I RD 2 1 TD 2 RD 2 TD Straight Through Cable Schema Switch Switch 3 TH 3 TD 6 TD 6 TD RD RD 2 RD 2 RD Crossover Cable Schema 5 EKI 2726FHPI User Manual m 10 100 1000Base T Pinouts The table below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5 BI_DC Bi directional pair C 6 BI_DB Bi directional pair B 7 BI_DD Bi directional pair D 8 BI_DD Bi directional pair D 10 100 1000Base T Cable Schema The following two figures illustrate the 10 100 1000Base T cable schema Switch Router or PC 1BIDA 1 BI_DB 2BIDA 2 BI_DB 3BIDB 3 BI_DA 6BIDB 6 BI_DA 4BIDC _ ________ 4BI_DD 5BI_DC 5 BI_DD 7 BILDD 7 BI_DC 8BI_DD 8 BI_DC Straight Through Cable Schema Switch Switch 1 BI_DA 1 BI_DA 2 BI_DA 2 BI_DA 3 BI_DB 3 BI_DB 6 BI DB 6 BI_DB 4 BI_DC 4 BI_DC 5 BI_DC Da 5 BI_DC 7 BI_DD gt lt 7 BI_DD Ve 8BI_DD 7 N 8 BI_DD Crossover Cable Schema EKI 2726FHPI User Manual 6 Chapter 3 Installation Caution 1 This equipment is intended for use in a Pollution Degree 2 indus trial environment VAN 2 This equipment is in
3. On Power input 1 or 2 has failed P Fail Red zur Off No failure occurs On The port is supplying power to the powered PoE indicator device Green Port 1 4 Off No powered device attached or power supplying fails On Connected to network Li Flashing Networking is active di Off Not connected to network Green On 1000M lower Off 100 10M On Connected to network 5 6 mini GBIC Green Flashing Networking is active Off Not connected to network EKI 2726FHPI User Manual 4 2 2 RJ 45 Pin Assignments The UTP STP ports will automatically sense for Fast Ethernet 10Base T 100Base TX or Gigabit Ethernet 10Base T 100Base TX 1000Base T connection Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each Tu wire pair j The table below shows the 10Base T 100Base TX MDI and MDI X port pinouts Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD m 10 100Base TX Cable Schema Switch Router or PC
4. for Fixing Wires Caution Use Copper Conductors Only 60 75 C tightening to 5 Ib in The wire gauge for the terminal block should be in the range A between 12 18 AWG 3 5 Wiring the Fault Alarm Contacts The fault alarm plugs are in the middle of the terminal block as the left picture shown below With a Normally Close circuit formed by wiring with an external power and a warning device a buzzer or a flashing LED system will detect the fault status includ ing the port linking failure managed industrial switch only and the power failure Please refer to the right picture below a wiring example for the fault alarm applica tion Figure 3 4 Terminal Block Plugs for Fault Alarm Contacts nt PWR2 pal PWR1 24Vdc 1A Resistance External Power Figure 3 5 Fault Alarm Wiring Example EKI 2726FHPI User Manual 12 3 6 3 6 1 Ethernet Cabling Use the four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long The small form factor pluggable SFP is a compact optical transceiver used in opti cal communications for both telecommunication and data communication Connecting the SFP Port To connect the transceiver and LC cable please take the steps shown as follows First insert the transceiver into the SFP slot Notice that the triangle mark indicates the bo
5. In this chapter the Industrial switch s dimensions definitions for LED indicators cabling information and wiring installation will be described 2 1 Physical Dimensions The PoE Industrial Switch dimensions W x H x D are 59 6mm x 152mm x 105mm as the figure shown below vieni 152 0 Dane e o o o 00 0 2 1 1 LED Indicators The diagnostic LED indicators located on the front panel of the industrial switch pro vide real time system information and operation status The table below provides the description status and definitions of the LED indicators for the switch Table 2 1 EKI 2726FHPI LED Indicators LED Color Description On Power input 1 is active Powerl Green l TE 7 Off Power input 1 is inactive On Power input 2 is active Power2 Green EE Off Power input 2 is inactive
6. User Manual EKI 2726FHPI 4 10 100 1000T 2 1000 Mini GBIC with 4 IEEE 802 3at High Power PoE Industrial Wide Temperature Switch AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2012 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 5 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for five years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to m
7. be easily monitored through LED indicators on the front panel which describe com mon problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in users may have a problem with the power cord Then check for loose power connec tions power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance If the Ethernet LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check your system s Ethernet devices configuration or status EKI 2726FHPI User Manual 16 Appendix B Technical Specifications B 1 Technical Specifications IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX Fast Ethernet IEEE 802 3ab 1000Base T Gigabit Ethernet PANNAN IEEE 802 3z 1000Base X Gigabit Ethernet over Fiber Optic IEEE802 3x Flow Control and Back Pressure IEEE802 3at Power over Ethernet Protocol CSMA CD Switch Architecture Back plane Switching Fabric 12Gbps Packet throughput ability Full Duplex 17 85Mpps 64bytes Transfer Rate 14 880 pps for Ethernet port 148 800 pps for Fast Ethernet port 1 488 000 pps for Gigabit Ethernet port MAC Address 8K entry MAC address table Connector 10 100 1000Base T 4 x RJ 45 1000Base X 2 x SFP PoE Pin Assignments RJ 45 port 1 4 support IEEE 802 3at End po
8. bly on the outside of the package and ship it prepaid to your dealer Part No Edition 2 Printed in Taiwan August 2012 EKI 2726FHPI User Manual ii Declaration of Conformity FCC Class A This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to pro vide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy lt may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures M Reorient or relocate the receiving antenna M Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Adva
9. ch Follow the instructions below to attach the industrial switch to ground 1 2 Caution When installing the industrial switch the ground connection must always i be made first and disconnected last On the top of the industrial switch locate and remove the dome screw which has a ground symbol beside it Attach the ground wire to the screw hole with the dome screw VI VI V2 V24 DC48V I a O O O 000 u C 0 CG 9 O 1A 24V co a MR Pral PWR FQ ig s o O 3 4 Wiring the Power Inputs Please follow the steps below to wire power lines from the terminal block to the com pliant external DC power source 1 2 3 Before wiring make sure the power source is disconnected Using the wire stripping tool strip a short piece of insulation from the output wires of the DC power source Identify the positive and negative feed positions for the terminal block connec tion See the symbols printed on the panel indicating the polarities and DC input power range in voltage Figure 3 2 Plugs for Power 1 amp Power 2 Insert the exposed wires into the terminal block plugs Only wires with insulation should extend from the terminal block plugs Note that the polarities between the wires and the terminal block plugs must be positive to positive and negative to negative 11 EKI 2726FHPI User Manual 5 Use a slotted screwdriver to tighten the captive screws DT000 DOVE Figure 3 3 Captive Screws
10. e is intended for reference purposes only AII product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2012
11. int Alternative A mode Each port provides 30W 55V power carring ability Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 LED Per unit Power 1 Green Power 2 Green P Fail Red Ethernet Link Activity Green Speed Green mini GBIC Link Activity Green PoE Green Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5e 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5e 6 cable EIA TIA 568 100 ohm 100m 1000Base T 2 pair UTP STP Cat 5E 6 or above cable EIA TIA 568 100 ohm 100m Power Supply DC 48V 2 5A redundant power with polarity reverse protection use DRP 240 48 the listed power supply manufactured by the MEAN WELL Company Power Consumption 5 5W Ethernet only Installation DIN Rail mounting Wall mounting Operating Temp 40 to 75 C 40 to 167 F Operating Humidity 5 to 95 Non condensing Storage Temp 40 to 85 C Dimensions IP 30 59 6mm W x 152mm H x 105mm D FCC Class A EMC CE EN61000 4 2 3 4 5 6 8 CE EN61000 6 2 CE EN61000 6 4 Safety UL 508 Hazardous UL cUL Class Division 2 Groups A B C and D Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration EKI 2726FHPI User Manual 18 EKI 2726FHPI User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guid
12. isuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visi
13. ntech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments Whether your new Advantech equipment is destined for the laboratory or the factory floor you can be assured that your product will provide the reliability and ease of operation for which the name Advantech has come to be known Your satisfaction is our number one concern Here is a guide to Advantech s cus tomer services To ensure you get the full benefit of our services please follow the instructions below carefully Technical Support and Assistance 1 Visit the Advantech web site at http support advantech com cn where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc Acomplete description of the problem The exact wording of any error messages iii EKI 2726FHPI User Manual EKI 2726FHPI User Manual Contents Chapter 1 Chapter 2 Chapter 3 3 1 3 2 3 3 3 4 3 5 3 6 Appendix A A 1 Appendix B B 1 Introduction
14. ooting mms 15 Troubleshooting roria el 16 Technical Specifications 17 Technical Specifications sssisness ne nehme nun 18 V EKI 2726FHPI User Manual EKI 2726FHPI User Manual vi Chapter 1 Introduction 1 1 Overview The High Power PoE Industrial Switch is a cost effective solution which meets the high reliability requirements demanded by industrial applications To solve the incon venience of wall outlet access the equipment is designed with power over Ethernet ports that comply with the IEEE 802 3at standard providing power as well as data over the conventional RJ 45 cables to the connected Powered Devices which need higher power consumption 1 2 Features m System Interface Performance RJ 45 ports support Auto MDI MDI X Function Embedded 4 port PoE Injection Store and Forward Switching Architecture Back plane Switching Fabric 12Gbps MAC Address Table with 8K entries m Power Input DC 48V Redundant Power Input Casel lnstallation IP 30 Protection Installation in a Pollution Degree 2 environment DIN rail and Wall mountings Design 1 3 Packing List Please refer to the package contents list below to verify them against the checklist POE Industrial Switch x 1 m User manual CD ROM x 1 Mm Removable Terminal Block x 1 Wall mount Kit 2 wall mount brackets with screws x 1 EKI 2726FHPI User Manual 2 Chapter 2 Hardware Description
15. tended for installation in an industrial control panel 3 1 DIN Rail Mounting 3 1 1 Assembling the DIN Rail Clip The DIN rail clip is screwed on the industrial switch when out of factory If not please refer to the following steps to secure the DIN rail clip on the switch 1 Use the included screws to secure the DIN rail clip on the industrial switch 2 To remove the DIN rail clip reverse step 1 GR DIN Rail Clip 9 Figure 3 1 Rear side of the Switch EKI 2726FHPI User Manual 8 3 1 2 Hanging the Industrial Switch Follow the steps below to hang the industrial switch on the DIN rail 1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail N i 2 Push the unit downward N 3 Check the DIN Rail clip is tightly fixed on the DIN rail 4 To remove the industrial switch from the track reverse the steps above 9 EKI 2726FHPI User Manual 3 2 Wall Mounting To hang the Ethernet switch on the wall please follow the steps below 1 2 3 Remove the DIN rail clip Prepare the two wall mount plates and six screws included Align the screw holes bewteen the wall mount plates and the unit as the figure illustrated Secure the plates to the unit with the accompanying screws EKI 2726FHPI User Manual 10 3 3 Grounding the Industrial Swit
16. ttom of the slot fel Inn triangle mark Figure 3 6 Transceiver to the SFP slot Figure 3 7 Transceiver Inserted 13 EKI 2726FHPI User Manual Second insert the fiber cable of LC connector into the transceiver Figure 3 8 LC connected to the transceiver 3 6 2 Disconnecting the SFP Port To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector from the transceiver and pull it out to release Figure 3 9 Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic part Figure 3 10 Pull out from the SFP slot EKI 2726FHPI User Manual 14 Appendix A Troubleshooting A 1 Troubleshooting Verify that you are using the included or appropriate power cord supplier adapter Please don t use the power supplier adapter with a non compliant DC output voltage or it will burn the equipment Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps connections or 1000 Category 5e above cable for 1000Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the Switch can