1. Test point for optical input level scaled at 1V mW Pacific Broadband Networks 3 October 2011 Page 9 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 6 External Layout CPON HFC Y DFB SC Receiver with Return Path Transmitter forward path and return path on separate fibres pen LIGHTLINK CPON HFC Item Description MOUNTING HOLES x 4 EARTHING TERMINAL 11 16 Vdc 500 mA OPT IN OPT OUT RF IN OUT RF T P 20 dB POWER LED CON O A FP WO N 9 OPT IN LED 10 OPT LEVEL T P 11 OPT OUT LED 12 OPT LEVEL T P Page 10 of 20 11 16 Vde P pee 8 POWER Mgt D dD Dor OPT LEVEL OPT LEVEL 1V mW 1V mW OPTICAL MICRONODE TRANSMITTER RECEIVER Power pass E RF IN OUT 3 October 2011 RF T P 20dB For fixing the unit to a wall or mounting surface For correctly earthing the unit DC power socket Optical input connector Optical output connector RF signal input output Forward path RF test point Unit power indicator On green Unit powered on Off Unit not powered Optical input power level indicator Green OK 8 dBm 0 dBm Amber Low lt 8dBm Red High gt OdBm Test point for optical input level scaled at 1V mW Optical output power level indicator On green OK Off Low Test point for optical output level scaled at 1V mW Optical output present
2. this product may cause radio interference in which case the user may be required to take adequate measures The product herewith complies with the requirements of the following directives and carries C 4 the CE marking accordingly e The EMC Directive 89 336 EEC e The Low Voltage Directive 73 23 EEC The product was tested in a typical configuration with Pacific Broadband Networks FCC WARNING This equipment has been tested and found to comply with the limits for class A device pursuant to Part15 of FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment NICATI9 X Ns 7 AL ger Coy SSO generates uses and can radiate radio frequency and if not installed in and used in ya Y accordance with the instructions may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense For Compliance Information ONLY contact Australia Pacific Broadband Networks 8 10 Keith Campbell Court Scoresby Victoria 3179 Australia Phone 61 3 9780 5100 Fax 61 3 9763 5522 Email sales pbn com au Europe Pacific Broadband Networks Phone 31 36 536 8011 Fax 31 36 536 4367 Email sales pbneurope eu China Pacific Broadband Networks Phone 86 10 5791 0655 Fax 86 10 5791 0855
3. esena E E 12 3 9 OS UI Cy US Gr Oe O mariu T E A adetee mouse wiatacea saad aaeas 13 4 Technical Description casaertoastearsaes qirutera qrecaranmiteenirssacbavetiad saatecosumaimaes Sune ncd sn ataaeaiaieces GiamtannGiesiaban 14 4 1 CO OW e a sine Seee eaeaeenntece ag ssoee senatnet aeasaecoeh E see asequenescie Sees 14 4 2 BOCK Dla Ol all ee anes rncuussumene ginemansnuatead seasesseqanadaaginenanqouitantquarsneuquuinataiaroasia 14 MES 2161 C721 1 oe none on te nie ee ane ee ee ere ee 15 OPPO CVV GUY ossen eni Gree ooeeaeeoece EE EE sananeen Gassaee ae 17 7 DeClaraOn Ol Con orny eccrine a Aa eE EE ania 18 o NOS e E E E nec siuntuenaiesoatsa 19 Pacific Broadband Networks 3 October 2011 Page 3 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 1 Precautions WARNING This equipment is intended for indoor applications To prevent fire or electrical shock or damage to the equipment do not expose units to water or moisture Ensure adequate cooling and ventilation as specified e The installation and operation manual should be read and understood before units are put into use e Always replace protective caps on optical connectors when not in use e The typical connectors fitted are SC APC 8 Note 8 angle polished connectors must be used Blue connectors indicate SC PC and Green connectors indicate SC APC Unused RF terminals
4. is prohibited CPON HFC Product User Manual 2 3 Models and Options CPON HFC Y Z SC Options Y 0 Forward path receiver only no diplexer 4254 5 42 54 1000 MHz split diplexer 6585 5 65 85 1000 MHz split diplexer Z Optical Laser for return path transmitter 0 Forward path receiver only no return path transmitter DFB Isolated DFB laser 1310 nm 2 mW 3 dBm Not available for models with return path transmitter installed Option Z must be 0 CPON HFC units are shipped in boxes of ten Please order CPON HFC in multiples of ten units 2 4 Typical Applications 2 4 1 CPON HFC 0 0 SC Forward Path Receiver only HEADEND NETWORK CUSTOMER PREMISES Power Supply CPON HFC 0 0 SC 11 16 Vdc Direct wy A Yr OL ret i ERMA FR a a or via ae PBN OCMR DOWNSTREAM FORWARD PATH RF 1285 1600 nm r Television 1 1 Power Inserter Power Inserter 1 x 32 Optical Splitter 32 Set Top Box LTM15 EDFAM 2 4 2 CPON HFC 6585 DFB SC Receiver with 2mW return path transmitter 1310 nm 65 85 MHz split diplexer HEADEND NETWORK CUSTOMER PREMISES PBN OCMR Power Supply DOCSIS PC FORWARD PATH RF 1285 1600nm CPON HFC 6585 DFB SC 11 16 Vdc Modem Direct A at 7 orvia A 1 Power Inserter 1 x 32 Optical eX i i Splitter Television RF Splitter a UPSTREAM RETURN PATH RF 1310 nm Set Top Box Page 6 of 20 3 October 201 1 Pacific Broadband
5. providing simplex or full duplex RF connectivity Employing leading edge designs for optical and electronic circuitry inside a die cast metal housing the CPON HFC provides top class services and permits easy installation in home wiring closets or other confined spaces The core of the CPON HFC is a high performance low noise optical receiver module for CATV to 1 GHz together with an optional return path transmitter module The receiver unit is capable of handling a very large number of radio and television channels with full support for DOCSIS broadband cable modems 2 2 Features Delivers full bandwidth CATV services to 1 GHz The duplex unit is suitable for advanced DOCSIS with Telephony and Internet e High performance optical receiver for CATV delivery over glass fibre with 110 NTSC channels or 91 PAL channels capacity e Suitable for transmission of PAL or NTSC analogue TV channels as well as DVB C or DVB T digital television standards e Wide optical input range permits easy installation without on site alignment e Optional return path transmitter to suit DOCSIS compliant cable modems and RF based pay per view systems e Powered by 11 16 Vdc either through the coax or through the DC power port e The compact and sturdy enclosure fits easily into wiring closets or network termination boxes Pacific Broadband Networks 3 October 2011 Page 5 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent
6. Any product that has been opened or modified without prior written permission from PBN Replacement of parts necessitated by normal wear and tear Any consequential or implied damages Pacific Broadband Networks will not be liable for DFB Laser failure after 90 days from receipt of item Any claim for DFB Lasers will be presented to the laser vendor for replacement Pacific Broadband Networks will make every effort to replace faulty lasers although ultimate judgement is at the laser vendor s discretion Pacific Broadband Networks will provide all labour costs associated with the replacement of the laser within the one year warranty period Pacific Broadband Networks 3 October 2011 Page 17 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 7 Declaration of Conformity According to ISO IEC Guide 22 and EN45014 Manufacturer s Name Pacific Broadband Networks Manufacturer s Address 8 10 Keith Campbell Court Scoresby Victoria 3179 Australia Declares that the product CPON HFC Customer Premises Optical Node Product Name for HFC Delivery Conforms to the following standards Safety EN 80083 1 EN 60950 IEC 950 AS NZS 3260 1993 EN 60825 1 IEC 825 1 AS NZS 2211 1 Laser Safety EMC EN 50083 2 EN 55022 1994 IEC CISPR 22 1993 AS NZS CISPR 22 2006 CATV HFC EN 50083 Supplementary Information CE This is a class A product In a domestic environment
7. C to the OPT IN port and confirm received level via optical level test point The OPT LEVEL LED should be green when the optical input level is within the correct range CAUTION If the OPT IN LED is red the optical input level is too high and is at risk of damaging the unit 3 Ensure the RF output level is within the desired output range by making use of the 20 dB forward RF test point 4 Ensure unused FF ports and test points are terminated using 75 Q terminators 5 CPON HFC Y DFB SC units only Connect return path fibre to the OPT OUT port Confirm that the optical output level is between 0 3 dB with an optical power meter Note The RF output level and OMI return path setting are factory set for optimum use In the case where adjustment is required remove the 6 base screws and set FR Gain Control amp ATTN1 accordingly Pacific Broadband Networks 3 October 2011 Page 13 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 4 Technical Description 4 1 Overview The CPON HFC is designed as an economic home termination unit for broadband passive optical networks BPON with cable television RF CATV overlay permitting transmission of many hundreds of simultaneous analogue and digital radio and television programs in analogue PAL NTSC or digital DVB standards HEADEND l PASSIVE OPTICAL NETWORK l CUSTOMER PREMISES l l l l TERA l D
8. Email office pbn com cn Americas Pacific Broadband Networks Americas LLC Phone 1 703 579 6777 x 567 Fax 1 703 935 4506 Email sales pbnamericas com Page 18 of 20 3 October 201 1 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 8 Notes Pacific Broadband Networks 3 October 2011 Page 19 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited PBN Pacific Broadband Networks Offices China Beijing tel 86 10 5791 0655 Americas Florida tel 1 703 579 6777 AsiaPac Melbourne tel 61 3 9780 5100 Australia Melbourne tel 61 3 9780 5100 EMEA Netherlands tel 31 36 536 801 1 info pbnglobal com www pbnglobal com 2011 Pacific Broadband Networks All rights reserved Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited
9. Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 Installation 3 1 Equipment Inventory On receiving your new CPON HFC you should carefully unpack and examine the contents for loss or damage that may have occurred during shipping Refer to warranty registration if loss or damage has occurred The CPON HFC should consist of the following Qty Description CPON HFC unit Product user manual includes individual test sheet Warranty registration certificate 75 Q terminator as fitted DL _ ot Universal mains power supply plug pack 3 2 Packaging and Transportation Keep all packing boxes and packaging of the CPON HFC for future transport Use only the original packaging of the CPON HFC when transporting This packaging has been specifically designed to protect the equipment 3 3 Power and Cooling Requirements The CPON HFC requires an external supply of 11 16 Vdc The power consumption of the unit is up to 6 W depending on configuration A universal 12 Vdc power supply plug pack is supplied with the unit and is suitable for 95 265 Vac 50 60 Hz with selectable mains pins for Australia China Continental Europe New Zealand United Kingdom and United States fF LES N 22AWG 24668 The CPON HFC is specified for operation between 10 C to 60 C Ensure that the unit is mounted in such a way as to permit airflo
10. No optical output Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited 3 Internal Layout Item Description 1 N A 2 CONN6 3 N A 4 FR Gain Control 5 ATTN 6 OPT IN 7 OPT OUT CPON HFC Product User Manual Optical forward path receiver diode Jumper terminal for power via RF IN OUT Optical return path transmitter laser Not fitted for CPON HFC 0 0 SC model Forward Receiver Gain Control OMI adjustment attenuator Not fitted for CPON HFC 0 0 SC model Forward path optical input Return path optical output Not fitted for CRON HFC 0 0 SC model For CPON HFC 0 0 SC units this port will be labelled RF OUT Pacific Broadband Networks 3 October 201 1 Page 11 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 8 Powering the CPON HFC The CPON HFC can be powered by either the supplied universal mains adapter plug pack or by providing power through coaxial cabling 3 8 1 Using the Mains Adapter Connect the lead from the mains adaptor to the DC power socket on the CPON HFC unit Ensure that the power adaptor plug is correct for the region of operation Plug the mains adaptor into a nearby wall socket CAUTION DO NOT attempt to supply power via the supplied universal mains plug pack and an RF port simultaneously Doing so may cause permanent damage to
11. OWNSTREAM l J CATV 1550 nm CPON HFC l l i l wy l 4 Television l l a l l l l l l i CATV pe ae Pe E b food l 1 x 32 Optical Splitter g i s LTM15 EDFAM A bay CPON HFC CAUTION A direct connection between laser transmitter and receiver will result in a permanent damage to the optical receiver Therefore an optical splitter and or optical attenuator is placed between the laser transmitter and receiver to ensure that the optical input power of CPON HFC will be between 8 dBm and 0 dBm 4 2 Block Diagram r _ _ _ nr X X X rr Or rr er er rr rr er rr rr rr er rr rr er rr er er er re er er er ee ee 9 eg Power In Optical Output 2 1mm Internal OMI Control sinh seem a i ce ak a as ns ena Paes Test Point i DPX RF IN OUT both receiver and transmitter I Only fitted for models with i I I I Forward Path Receiver Forward Optical RX Optical Input Internal RF Output Control 8 0 dBm CPON HFC Page 14 of 20 3 October 2011 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 5 Specifications Forward Path Optical Wavelength Input level Recommended input level Connector Return loss Input level test point Forward Path RF RF output level RF bandwidth RF flatne
12. PBN Pacific Broadband Networks Light Link CPON HFC Customer Premises Optical Node for HFC Delivery Product User Manual Offices China Beijing tel 86 10 5791 0655 Americas Florida tel 1 703 579 6777 AsiaPac Melbourne tel 61 3 9780 5100 Australia Melbourne tel 61 3 9780 5100 EMEA Netherlands tel 31 36 536 801 1 info pbnglobal com www pbnglobal com 2011 Pacific Broadband Networks All rights reserved Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual Light Link CPON HFC Customer Premises Optical Node for HFC Delivery Product User Manual wena nen nen nena eee O EEO ROSES RSE EOS EERO RSE EO ESR E ORO RS REO EO ESR E ORO RSRE EO RSRO HORSES HORSES EO RSROSEORSRSEOHSRSGEORSRSGEOHSRSGEORSROGEOHSRSGEOHSRSGEOHSROGEOHSRSGEOHSRSGEOHSRSGEOHSEOGEOHSROGEOHSRSGHORSRSGEOHSROGEOHSROGEOHSRSGEOHSRSGESHSRSSEOHSRSSEOHSRESE _Lastupdate 8 October 201t Document version o 2 oZ Z Z Aa y l Document reference sss PBN CPON HFC Manual V4a Released 03 Oct11 Document status Released o 2 Prepared DY ss Pacific Broadband Networks a Preparedfor Product Users Page 2 of 20 3 October 201 1 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual Contents T CANONS srateeertrsedien ten ane A E E E A E E 4 2 68 6 065 16 unei E E E ee ee ae e
13. ee 5 2 1 B n E E EE EE E ee E AAE E A A E 5 2 2 FUSS nocmeeai ea EE E EE A EER EAER 5 2 3 Model and OPUONG prt cnc eect EE EE EEE 6 2 4 Typical APPICATONS serricornis 6 2 4 1 CPON HFC 0 0 SC Maer eee ene ee eee eee ee 6 24 2 GPON AFGC 6585 DRB SC isos cabs sce savesesvessesuseeatesssisasegnsebavectsbesnesnsbeaieseebeadeanssbavectebecseousese 6 eM SUTURE OV ccteasce satire ard ects act ade adineseate ste end sherieedvicadecuass ceed iced etree oaub aia tadidea EE 7 3 1 EOUIDMENT IVS IONY sacitcunsat cocuinasnsnarhaindmusdsraniiuaeed sev tmerasutbenadonsdedadiussesbineipennsnstbeiadansditetionestbseuaad 7 3 2 Packaging and TrANSPOrtatiON ccccccseeeeccceeeeeceeeeeeseeeeeesseeeeesseeeeeseeeeeesaueeessaneeessaeeeeesaags 7 33 Power and Cooling REQuire Ment ccccccccsssseseecceceeeeeeeeeeeeceeeeesaeeseeceeeeessueeaeeeeeeeeseseaasesss 7 3 4 POINT UN ace eerste he ccdarna tee acces oh arneniastion a hae pleated pehemnhaate aha aitictinglit Codie in siteiieinh dentate suuvesttaunien 8 3 5 External Layout CRON HPG 0 02 SC siicteceidecccchiabdensdadecqatdadseustadelexebiodleazsndetevsvindhectideiecsbicas 9 3 6 External Layout CPON HFC Y DFB SC si cccesedccccestectertecsiceceesiedeeceedcenees tecdendexsicexeaeeedeeeaeseues 10 our PTS Fre MeV OU suaceetetans smear itatetat caaateanavedarsnnananieca E 11 3 8 POWerING Te OPON HF O asarsaran ENEE EEE waareceone 12 361 USnothe Mans Adapter crimisoerisieia id n eia daid 12 382 FOWGMN VISARE PO
14. ility of Pacific Broadband Networks under this warranty is solely limited to repairing replacing or issuing credit provided that 1 The warranty registration has been completed and received by Pacific Broadband Networks Pacific Broadband Networks helpdesk is promptly notified in writing or by telephone that a failure or defect has occurred A return authorisation number is obtained from Pacific Broadband Networks helpdesk and clearly marked on the outside of the shipping container and all documents Customer is responsible for all shipping and handling charges C O D and freight collect will not be accepted without prior approval from Pacific Broadband Networks helpdesk The equipment in PBN s sole discretion has not been abused misused or operated under conditions outside manufacturer s specifications The warranty does not cover the following 1 O OD ND Oo Products purchased from someone other than an authorised Pacific Broadband Networks dealer Damage caused by accident negligence misuse abuse improper operation or failure to operate the equipment within the manufacturer s specifications Damage caused by fluctuation in electrical current lightning power surges etc Damage resulting from overhaul repair or attempt to repair caused by someone other than Pacific Broadband Networks qualified service personnel Any product in which the serial number has been defaced modified or removed
15. ins plug pack Operating Temperature Dimensions H x W x D Net Unit Weight Shipping Dimensions Shipping weight and volume 1310 nm 2 mW 3 dBm SC APC gt 45 dB 1V mW 5 45 MHz or 5 65 MHz 0 75 dB gt 14dB 20 dB 11 16 Vdc 400 mA 12 Vdc 450 mA 12 Vdc SC APC SCTE F type 2 1 mm concentric positive on centre pin 95 265 Vac 50 60 Hz with AU EU UK US mains pins 10 60 C ambient 115 x 163 x 38 mm CPON 0 38 kg Power pack 0 22 kg Box of 10 units 170 x 525 x 380 mm 34dm3 Box of 10 units 7 7 kg 2 A universal mains plug pack is supplied with the CPON HFC unit The plug pack is suitable for 95 265 Vac 50 60 Hz and has selectable mains pins for Australia China New Zealand Continental Europe United Kingdom and United States 3 CPON HFC optical receivers are supplied in bulk pack cartons of ten units including universal mains power plug packs Single unit packing is available as a customer option at an additional cost Page 16 of 20 3 October 2011 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 6 Product Warranty Pacific Broadband Networks warrants its equipment to be free of manufacturing defects in material and workmanship for a period of one year from date of shipment provided it is installed and operated in accordance with factory recommendations The liab
16. must be fitted with the supplied 75 Q terminators Dangerous voltages are present within the power supply adaptor at all times Mains power kills Do not operate the unit without all covers and panels properly installed Cleaning Use only a damp cloth for cleaning the unit Do not use spray cleaner of any kind Overloading Overloading wall outlets and extension cords can result in a risk of fire or electric shock Use appropriately rated electrical cords and power plug packs Damage requiring service Unplug unit and refer servicing to Pacific Broadband Networks qualified service personnel only Servicing Do not attempt to service this unit yourself Refer all servicing to Pacific Broadband Networks qualified service personnel only WARNING Exposure to class 1M laser radiation is possible Access should be restricted to trained personnel only Do not view exposed fibre or connector ends when handling optical equipment Page 4 of 20 3 October 2011 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 2 Introduction 2 1 Overview The Light Link CPON HFC customer premises optical node for FTTH networks offers full bandwidth cable television delivery plus broadband access via DOCSIS cable modems Fibre to the home FTTH is a reality today The CPON HFC is designed as an economic single port node customer premise deployment
17. ss RF output return loss RF output test point Link Performance CNR CSO CTB Forward Path CNR 66 D f Bef 0 Incident optical power dBm e 3 2 OM 4 0 OMI amp 5 0 OMI Pacific Broadband Networks 1285 1600 nm 8 dBm to 0 dBm gt 5 dBm SC APC gt 45 dB 1V mW 20 dBmV 54 1000 MHz or 85 1000 MHz 1dB gt 14dB 20 dB gt 46 dB gt 60 dB gt 65 dB 1 Measured in a typical 1310 nm transmission system with PBN LTM13 optical transmitter and 5 km of single mode fibre to the CPON HFC aligned for the recommended nominal optical input power of 5 dBm with 42 Cenelec carriers and 4 optical modulation index Relative Noise Bandwidth RNB 5 MHz for PAL television channels In 1550 nm systems the RF output levels are 1 dB more and the CNR performance is 1 dB better CNR performance for NTSC television channels with 4 MHz RNB is another 1 dB better 3 October 201 1 Page 15 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual Return Path Optical Wavelength Output level Connectors Return loss Output power test point Return Path RF RF bandwidth RF flatness RF input return loss RF input test point General Specifications External Power Supply CPON HFC 0 0 SC CPON HFC Y DFB SC Optical connectors RF connectors Power connector Universal ma
18. the unit 3 8 2 Powering via an RF Port To enable power through coax via RF OUT CPON HFC 0 0 SC units only or via RF IN OUT 1 Remove rear cover plate to reveal CPON HFC internal circuitry 2 Connect jumper plug to terminal CONN6 see Section 3 7 CAUTION DO NOT attempt to supply power via an RF port without the corresponding jumper plug installed Doing so may cause permanent damage to the unit DO NOT attempt to supply power via two RF ports simultaneously Doing so may cause permanent damage to the unit Note A jumper plug is factory supplied and factory fitted to 1 pin only Place jumper over both pins to enable power through coax operation Page 12 of 20 3 October 201 1 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 9 Setting up the CPON HFC WARNING Exposure to class 1M laser radiation is possible Access should be restricted to trained personnel only Do not view exposed fibre or connector ends when handling optical equipment 1 Connect the power pack to the unit via the POWER IN port and confirm the Power LED is green Before connecting the SC APC to the OPT IN port verify that the optical power level is between 8 dBm 0 dBm using an optical power meter Ensure optical power remains below 0 dBm so as to prevent damage or desensitisation of optical receiver 2 Connect SC AP
19. w around the front and sides at all times Pacific Broadband Networks 3 October 2011 Page 7 of 20 Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 4 Mounting The CPON HFC has four mounting holes The unit is designed to be a flexible and environmentally friendly unit and as such can be mounted in a number of ways to suit the required scenario However it is important to ensure that free air space is maintained across the heat dissipating fins at the top of the unit It is not recommended to mount the unit upside down POWER EPpen pie OPT LEVEL LIGHTLINK OPTICAL MICRONODE CPON HFC RECEIVER i Page 8 of 20 3 October 201 1 Pacific Broadband Networks Downloaded 12 10 2011 by pdhondt home nl Reproduction without consent is prohibited CPON HFC Product User Manual 3 5 External Layout CPON HFC 0 0 SC Forward Path Receiver Only Item Description 1 MOUNTING HOLES x 4 For fixing the unit to a wall or mounting surface 2 EARTHING TERMINAL For correctly earthing the unit 3 11 16 Vdc 500 mA DC power socket 4 OPT IN Optical input connector 5 RF OUT RF signal output 6 RF T P 20 dB Forward path RF test point 7 POWER LED Unit power indicator On green Unit powered on Off Unit not powered 8 OPT IN LED Optical input power level indicator Green OK 8 dBm 0 dBm Amber Low lt 8 dBm Red High gt 0 dBm 9 OPT LEVEL T P