1. 5 TASE Identifying the wiring terminals on a ler ne the module 5 wines for 3 any ciut Traveler Neutral Red Other White 1 Line Hot Black 2 Neutral White 4 Traveler 3 way Ciel ed or Other Green Bare p04 LinetHOT Black 5 Load Black oo tien rn Parameter 9 level 1 Turn the connected lighting On Off Length 1 Byte and Dim Valid Values 1 99 default 1 indicates the number of levels the lighting will change 2 Add Include or Delete Exclude your WD 100 to from your network when the timer runs out 3 Assign your WD 100 to a specific Parameter 10 timer Group and or to include your Length 1 Byte WD 100 as part of your All ON or Valid Values 1 255 default 3 indicates OFF command the time duration of each level 4 Over the Air firmware by your The resolution is 10 milliseconds For gateway or static controller example a default value of 3 means the timer runs out every 30 milliseconds Using the combinations of these 2 parameters you can create a dim rate adjustment range as 5 Lifeline function which automatically notifies the associated modules and the network that a manually reset device is no longer in the network thus the corresponding association can create a dim rate adjustment range as becomes invalid short as 10 milliseconds to a very slow dim rate About the Z Wave 500 Series module You can use a Z Wave certified portable or static controller
2. aragon tech This product speaks with other Z Wave certified devices Wireless Dimmer Module WD 100 In Wall Dimmer A Z Wave certified controller of either portable or static is capable of setting up dragon tech products in your desired network Once the module is added you may assign it to a Group change its reaction when the All command ON or OFF is received Furthermore it can be set in Association with another Z Wave device to perform a specific function Please refer to the instructions manual of your remote controller for details and procedures on how these settings can be done Please note that the module will be OFF after a power failure About the rocker switch There is only 1 rocker switch on this module for manual operation that allows you to 1 Turn the connected lighting ON OFF and DIM by tapping the switch Tapping and releasing the upper part of the rocker turns the lighting ON Tapping and releasing the lower part of the rocker turns the lighting OFF Press and hold the upper part of the rocker to Dims Up the lighting Press and hold the lower part of the rocker INTRODUCTION dragon tech WD 100 is a member of the Z Wave family and communicates with other Z Wave certified devices in a control network WD 100 replaces a standard in wall light switch and turns it into a Z Wave controlled network device with dimming and On Off light control Each Z Wave device serves as a node to repeat the
3. eceiver 3 way circuit WD100 WS100 a Black Line WA100 20VAC 60Hz Load Neutral White Making connections Traveler Red Other Ground Load Line HOT Green Bare Black nen Black Connect the equipment into an outlet on a tircuit different from that to which the receiver is connected Consult the dealer or an experienced tadio TV technician for help Operation is subject to the following two conditions e This device may not cause interference e This device must accept any interference including interference that may cause undesired operation of the device Important Note To comply with the FCC RF exposure compliance requirements no change to the antenna or the device is permitted Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user s authority to operate the device Caution Exposure to Radio Frequency Radiation To comply with FCC C RF exposure compliance requirements a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons This device must not be co located or operating in conjunction with any other antenna or transmitter Please refer to WA 100 user manual for wiring instructions of the auxiliary switch The maximum length of Traveler wire may not exceed 200ft Gang Box To install the WD 100 in a gang or J box the tabs on the sides of the metal
4. es from various classes of products and these devices can be made by different manufacturers The dragon tech product introduced in this instructions manual has a Z Wave certification which guarantees such an interoperability Making connections Line HOT Ground Load Green Bare Black Black TheAtaveler terminal is not used in a ay circuit Do not remove the insulation pe on the Traveler terminal in this application FCC ID 2ABWCWD100 The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph The equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment uses generates and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuming the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and r
5. g WD100_08292014_En_v1 5 2 Quickly tap the top side ON of the rocker 3 times If you see the lighting turns OFF it means that iene has been reset z successfully and you may r tep 5 above to add the eerie int Ser network Otherwise please repeat the manual reset procedures Note if the module is previous Added Included in your network resetting it locally does not mean it has been removed from your network You may still need to Delete Exclude the module from the network by your controller if desired Use the manual reset procedure only in the event that the network primary controller is lost or otherwise inoperable Then quickly tap the bottom side OFF of the rocker 3 times The connected lighting can be controlled manually with a rocker Wirelessly with a remote controller
6. lem dragon tech s sole obligation under the foregoing warranty is to repair replace or correct any such defect that was present at the time of delivery or to remove the product and to refund the purchase price to customer The warranty does not extend to consequential or incidental damage to other products that may be used with this product For inquiry and customer service email to support dragontechind com All brand names shown are trademarks of their respective owners Warranty period limited 1 year from date of purchase JESE When proper wiring is completed secure the module to the wall box Restore power to the circuit to test if the connected lighting can be tumed ON OFF Dim manually by the rocker on the module before remounting the wall plate Also observe the status change of the LED indicators to ensure the module is in normal operating mode If WA 100 Auxiliary Switch is used for a 3 way connection please also test if it can control the lighting SGU Add include the module into your network by a Z Wave certified controller Please refer to the controller s instructions manual for details Manual Reset Note If Inclusion still fails after the 2nd attempt you need to first reset the module before repeating the above steps The manual reset method is as follows 1 Turn the connected lighting ON with the rocker dragon tech Products RM 302 Hanley House 776 778 Nathan Rd Mongkok Kowloon Hong Kon
7. signal in the network thus extending the overall Z Wave mesh wireless network range Different types and brands of Z Wave devices can associated with dragon tech WD 100 in your system and they will work together to optimize and expand the coverage of your Z Wave network Once setup is completed you can miey the conveni ence and leisure which WD 100 offers to Dim Down the lighting Simply release the rocker when the desired brightness level is reached during dimming 2 Add Inctude or Delete Exclude the module to from your Z Wave network with your primary controller Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done Normally the sequence is as follows when the inclusion or exclusion process is prompted by your primary controller single click and release the rocker switch gt the controller should show that the action was successful gt if the controller shows it was a fail repeat the procedure Note the orientation of the ON OFF on the rocker switch can be inverted by changing the following configuration with a controller if supported Parameter 4 Length 1 byte Valid values 0 or 1 default 0 Works with incandescent and dimmable florescent CFL or LED lighting 7 LED indicators for ON OFF Dimming level status e Can be controlled wirelessly or manually e Fits into standard single or multiple gang junction bo
8. the following method 1 Lift the air gap switch up to avoid ock electrical s 2 Push side tabs in and lift the cover plate up to release Only the bottom 4 LED indicators are ON when the connected lighting is at around half of it s full brightness 50 60 Note there are some occasions when the lighting is dimmed down to the minimum brightness level only the bottom LED is ON but it appears OFF visually Depending on the lighting devices used the behaviors vary You may check the actual lighting status with the indication of the bottom LED By default the LED indicators will go off in a few seconds after showing the dimming level You may check the lighting status by tapping the top of the rocker or the corresponding ON key on the controller to reactivate the LEDs About dimming The time interval of brightness change between dimming up and down can be adjusted by changing the following configuration with a controller if supported 3 Align the tabs of the replacement cover IREYA WARNING RISK OF SHOCK Make plate and push to snap in sure power is OFF before wiring Remove the wall plate and the existing switch if mounted at your preferred installation location You should label the wires connected to the screw terminals before disconnecting the switch Please check that the wiring configuration below is present in the wall switch box otherwise consult a qualified electrician
9. to communicate with the module 2 Depending on the capability of your controller or gateway software the following 3 simple to advanced operations can be performed Please refer to the controller s or gateway manual for details Association 1 WS 100 supports association command class WS 100 only supports group 1 for lifeline communication You can associate up to 5 Z Wave devices to group 1 4 Lifeline association only supports the manual reset event Wiring Information Use copper wires only UL specification the tightening torque for the screws is 14 Kgf cm 12 Ibf in Strip insulation 5 8 16mm Wire connection can be made either to Screw terminal 14 AWG or larger rated at least 80 C Hole 14 AWG rated at least 80 C 2 way circuit WD100 di Line 120VAC 60Hz Load l ee 5 For instructions on how to set lifeline associate please refer to your wireless controller instructions Model WD 100 Input power 120 VAC 60 Hz Max output loading 1x gang box 600W incandescent 150W dimmable CFL LED 2x gang box 500W incandescent 125W dimmable CFL LED 3x gang box 400W incandescent 100W dimmable CFL LED Radio frequency 908 4 916 MHz Wireless range up to 130ft line of sight between the controller and the other available nodes Normal operating temperature 77 F 25 C For indoor use only Interoperability with Z Wave devices A Z Wave network can integrate devic
10. x and standard wall plates Decorative keypad can be replaced manually to match color with other wall switches Over The Air firmware upgrade available with compatible gateway Z Wave static controller PC and software e Z Wave 500 Series module inside Internal resettable fuse to protect from surge Current e Manual reset capability WARNING RISK OF FIRE ELECTRICAL SHOCK amp BURNS DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENT No user serviceable parts are in this module The lighting connected to the WD 100 must not exceed 600W incandescent 150W dimmable CFL LED CAUTION To Reduce the Risk of Overheating And Possible Damage To Other Equipment Do Not Install To Control A Receptacle A If value 0 the connected light will turn ON by pressing the top side of the rocker switch and turn OFF by pressing the bottom side If value 1 the connected light will turn OFF by pressing the top side of the rocker switch and turn ON by pressing the bottom side About the 7 LED indicators There are in line 7 LED indicators on this module to display the connected lighting Status All 7 LED indicators are ON when the connected lighting is at full brightness 100 All 7 LED indicators are OFF when the connected lighting is shut off 0 Motor Operated Appliance A Non Dimmable Fluorescent Lighting Fixture Or A Transform er Supplied Appliance The color of the red switch is changeable by
11. yoke may need to be removed For single gang switch no changes should be required For dua or higher gang configuration where switches are next to each other the tabs need to be removed Simply take a pair of pliers grab the tabs and wiggle until the tabs break off This will lower the electrical rating of the module Please refer to the following details 1x gang box rating 600W incandescent 150W dimmable CFL LED with 2 side tabs IC 11786A WD100 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Z Wave is a registered trademark of Sigma Design dragon tech warrants to the original purchaser of this product that for the warranty period this product will be free from material defects in materials and workmanship The foregoing warranty is subject to the proper installation operation and maintenance of the product in accordance with installation instructions and the operating manual supplied to customer Warranty claims must be made by customer in writing within 30 days of the manifestation of a 2x gang box rating 500W incandescent 125W dimmable CFL LED with 1 side tabs 3x gang box rating 400W incandescent 100W dimmable CFL LED with no side tabs prob