Home

UV 100W COB Flood

image

Contents

1. Sh UV 100W COB Flood 1 x 100W UV LED User Manual Order code LEDJ185 Safety advice WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty CAUTION CAUTION TAKE CARE USING KEEP THIS EOUIPMENT THIS EOUIPMENT AWAY FROM RAIN MOISTURE AND LIOUIDS HIGH VOLTAGE RISK OF ELECTRIC SHOCK IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the eguipment e Never let the power cable come into contact with other If the eguipment is dropped or damaged disconnect the cables Handle the power cable and all mains voltage mains power supply immediately and have a gualified connections with particular caution engineer inspect the eguipment before operating again e Never remove warning or informative labels from the unit If the eguipment has been exposed to drastic Do not open the equipment and do not mo
2. 01 Safety eye IM 02 Earth point MENU ENTER UP DOWN 03 LED display 04 Function buttons 05 DMX input socket 06 DMX output socket 07 Captive power connection 08 Fuse F2A 250V www prolight co uk CE X f Please note The COB UV LED installed into this fixture has dispersed LED emitters you may notice that not all pixels will illuminate This is to enable better cooling across the chip and does not indicate a faulty LED www prolight co uk UV 100W COB Flood User Manual 3 Operating instructions DMX channel mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently To access the DMX channel mode press the MODE button on the rear of the unit to show AUG I on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the desired DMX address Now press the ENTER button to choose one of the 1 or 2 DMX channel modes using the UP and DOWN buttons and press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button 1 channel mode 2 channel mode Value 000 255 Master dimmer 0 100 000 255 Master dimmer 0 100 000 255 Flash speed slow to fast Static mode To access st
3. assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements for DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split www prolight co uk UV 100W COB Flood User Manual 5 DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR AEE RE DN RT OE XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Q Pin 2 Negative 3 Hot 3 Hot Special note Line termination When longer runs of cable are used Termination reduces signal transmission you may need to use a terminator on problems and interferance it is always the last unit to avoid err
4. atic behaviour advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibilities of erratic behaviour 3 pin Order ref CABL90 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in toa 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR socket Pin 1 GND screen 3 pin XLR socket Pin 2 Signal ami Pin HE GND screen Pin 3 Signal Pin 2 Signal Pin 4 N C Pin 3 Signal Pin 5 N C 5 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal gt wa 2 www prolight co uk UV 100W COB Flood User Manual 6 WEEE notice Correct Disposal of this Product Waste Electrical amp Electronic Eguipment Applicable in the European Union and other European countries Si with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environme
5. atic mode press ENTER until the display shows 00 on the LED display To adjust the brightness use the UP and DOWN buttons to select between 00 99 Press the ENTER button to confirm the setting Now use the UP and DOWN buttons to adjust the flash speed by selecting between L F OO CF99 Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Slave mode Press the MODE button on the rear of the unit to show 5L AL on the LED display and press the ENTER button to confirm the setting The unit will now run in seguence with the master unit To exit out of any of the above options press the MODE button Please ensure that all slave units are set to the same DMX channel mode as the master unit Sound active mode To access the sound active mode press the MODE button on the rear of the unit to show SUND on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from SHOO 5499 and press the ENTER button to confirm the setting Value 00 99 00 low 99 high To exit out of any of the above options press the MODE button Menu system Address setting ADD 1 A5 12 www prolight co uk UV 100W COB Flood User Manual 4 DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Eac
6. dify the unit temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors If your product fails to function correctly stop use Do not expose to flammable sources liquids or gases immediately Pack the unit securely preferably in the e Always disconnect the power from the mains when original packing material and return it to your Pro Light equipment is not in use or before cleaning Only handle dealer for service the power cable by the plug Never pull out the plug by pulling the power cable Repairs servicing and power connection must only be e Make sure that the available voltage is between carried out by a qualified technician THIS UNIT CONTAINS 110 240V 50 60Hz NO USER SERVICEABLE PARTS e Make sure that the power cable is never crimped or WARRANTY One year from date of purchase damaged Check the equipment and the power cable periodically Only use fuses of same type and rating OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operatio
7. h fixture reguires a start address from 1 512 A fixture reguiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is
8. n may lead to danger e g short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk UV 100W COB Flood User Manual 2 Product overview amp technical specifications UV 100W COB Flood Featuring COB chip on board technology the LEDJ UV 100W COB Flood is loaded with a 100W UV LED which is housed in a 50 reflector Control of the unit is facilitated via a 4 button menu and LCD display The whole fixture is enclosed in a robust cast aluminium housing e 1x 100W UV COB LED Beam angle 50 field angle 80 e 1 1kHz refresh rate e DMX channels 1 or 2 selectable e Stand alone sound active and master slave modes e 0 100 dimming with variable strobe e 4 push button menu with LED display e Captive power connection e 3 pin XLR in out sockets e Fan cooled e Supplied with hanging bracket and filter frame e Optional 10 ELUM102 or 25 ELUM103 lenses e Optional Barn Doors ELUMO41C In the box 1 x fixture amp 1x user manual Specifications UV 100W COB Flood Power consumption 110W Power supply 110 240V 50 60Hz Fuse F2A 250V Dimensions 303 x 300 x 180mm Weight 3 7kg Order code LEDJ185 280mm O POWER SUPPLY FUSE F2A 250V 100 240V 50 60Hz 5 a COB FLOOD Hf Wi
9. nt or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal CE f www prolight co uk UV 100W COB Flood User Manual 7 www prolight co uk UV 100W COB Flood User Manual 8

Download Pdf Manuals

image

Related Search

Related Contents

Nexus 4x4 User Manual  Manual PDF  PINTURA PISCINAS NEPTUNO  AIRCRAFT OPERATING INSTRUCTIONS Light  IMPORTANT – Please make certain that persons who  intext:Bedienungsanleitung filetype:pdf  Samsung Full HD Monitor S22D390Q LED(22") Priručnik za korisnike  取扱説明書 - ご家庭のお客さま/大阪ガス  EliteGroup P4S5A Motherboard  