Contents

1. 54 User s Manual Zone and Area Entry Description 1 2 3 4 Delay 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Byp Stay Force 24Hr Digiplex LCD Keypad s 55 Exit Delay Area 1 is seconds Area 2 is seconds Area 3 is seconds Area 4 is seconds The entry delays appear in the Zone Description table 11 2 Access CODES For security reasons write only the user s name and not his or her access code Place a v in the sguares to identify which options are enabled 4 Digit Codes 6 Digit Codes 1 to 6 Digit Codes L Keypad Duress obeys code Area Full A 1234 Master Master Byp Stay Force r User Name Only System Master 1234 Vo NA VY v Code 02 03 04 05 06 07 08 56 User s Manual Keypad Duress obeys code Area Master Ful Byp Stay Force GA User Name 1534 Master 09 10 11 12 13 14 15 16 17 18 19 20 21
2. kry If enabled by the installer the One Touch Buttons section 4 6 or a keyswitch section 4 7 can also be used to arm the area 4 5 FORCE ARMING Force Arming allows you to arm your system when specific zones are open Certain zones can be programmed by the installer to remain unarmed when you initiate Force Arming Once the open zone is closed however the system will then arm 16 User s Manual it as well Only User Access Codes with the Force Arm option enabled can Force Arm the system This feature is commonly used when a motion detector is protecting an area that is occupied by a keypad During Force arming the motion detector will remain unarmed until you exit the area that it protects The system will then arm the motion detector How do Force Arm 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the button If you have access to more than one area press the area s na m the 0 button for all areas or use the Ca and CY buttons and press Ente when the area you want to Force Arm appears After the Confirmation Beep Force Arming will appear briefly on LCD screen and the exit delay timer will begin ay if enabled by the installer the One Touch Buttons section 4 6 or a keyswitch section 4 7 can also be used to arm the area Digiplex LCD Keypad s 17 4 6 ONE TOUCH BUTTONS At the touch of a button you can view the Area Status Displa
3. 22 23 24 25 26 27 28 Digiplex LCD Keypad s 57 Keypad Duress obeys code Area Full Ar User Name 1234 Master Master Byp Stay Force Only 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 58 User s Manual Keypad Duress obeys code Area Master Ful Byp Stay Force GA User Name Master 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Digiplex LCD Keypad s 59 11 3 SPECIAL BUTTONS AND FEATURES One Touch Buttons Place a v if the One Touch Button is activated Stay Arm pora Force Arm A ARM Regular Arm posa Disarm Stay lnstant Arm Panic Alarms Place a v if the Panic Button is activated silent or audible AREA 4 asray Auxiliary or OES 8 Ce 7 Bypass Programming INSTANT 5 Instant Arm DISPLAY 6 Keypad Settings KB 8 685 Emergency or Silent Silent Silent EVENT
4. 4 8 1 Timed Auto Arming If enabled you can set the time that an area will arm itself automatically Digiplex LCD Keypad s 19 How do set the Auto Arming timer 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the Co button 3 Press the Mem button If you have access to more than one area press the area s number or use the Ca and C v buttons and press the aco button when the area you want to program appears on screen 4 Enter the TIME you want the area to be armed according to the 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 5 Press the button to save and exit 4 8 2 No Movement Auto Arming Your system can be programmed to send a report to the Security Company and or arm the system if there is no activity in the area during a specified period of time Speak to your installer about this feature 4 9 BYPASS PROGRAMMING The installer can program certain zones with the bypass option so you can program the system to bypass certain zones when you arm the protected area When a zone is bypassed it will remain unarmed once the system is armed This option may be useful for example when renovating part of the protected area 20 User s Manual Bypassed zone s will be kept in memory until the area is armed Once the area is disarmed the system will unbypass the zones To bypass a zone The zone must have the Bypass option progr
5. After the Confirmation Beep Stay Arming should appear on the LCD screen and the exit delay timer will begin kry If enabled by the installer the One Touch Buttons section 4 6 or a keyswitch section 4 7 can be used to arm the area 4 4 INSTANT ARMING This feature is similar to Stay Arming Instant Arming will partially arm your system to permit you to remain in the protected area but all zones including the entry exit point are changed to instant alarm zones Therefore if any armed zone is breached the alarm will instantly be triggered Only User Access Codes with the Stay and Instant Arm option enabled will be able to Instant Arm Digiplex LCD Keypad s 15 4 4 1 Instant Arming with Delay Instant Arming with Delay functions like Instant Arming except the installer can program certain armed zones within the protected area s with an Entry Delay Timer lf these zones are accidenily triggered the timer will start to allow you enough time to disarm the area s How do Instant Arm 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the 5 button If you have access to more than one area press the area s number press the C o D button for all areas or use the C a and C v gt buttons and press when the area you want to Instant arm appears After the Confirmation Beep Instant Arming will appear briefly on LCD screen and the exit delay timer will begin
6. system is running on the back up battery This trouble can be programmed not to appear on the LCD screen when it occurs The AC Light on your keypad will be turned off during a power failure If this trouble occurs when your establishment is not experiencing a power failure call your Security Company for repairs Battery Trouble The back up battery is disconnected needs to be recharged or replaced AUX Current Limit Devices connected to the control panel have exceeded current limits The Auxiliary Output will shutdown until the trouble has been rectified Bell Current Limit The bell or siren connected to the control panel has exceeded current limits The Bell Siren Output will be shutdown until the trouble is rectified Bell Absent The control panel has detected that the bell or siren is not connected ROM check Error The control panel registers a memory error 34 User s Manual 7 0 2 Group 2 Communicator TLM Telephone Line Monitor The control panel is unable to access the telephone line Fail to Communicate 1 Fail to Communicate 2 Fail to Communicate 3 Fail to Communicate 4 The control panel has tried all assigned telephone numbers and has failed to communicate with the Security Company Fail to Communicate PC The control panel is unable to communicate with the Security Company s diagnostic software 7 0 3 Group 3 Modules Trouble Module Tamper The control panel registers that someone has triggered the ta
7. Erasing Access Codes 26 5 3 System Master Code 27 5 4 User Access Codes 27 TROUBLE DISPLAY iii iii 33 6 1 Event Record Display 38 ADDITIONAL FEATURES 40 7 1 Programmable Outputs PGMs 40 7 2 Keypad Settings 40 7 3 Set Time amp Date oo eee ee ee ee ER ee ee 42 7 4 Programming Chime Zones 42 7 5 Panic Alarms iniaa oe egg 44 7 6 Quick Function Buttons 45 FIRE AND BURGLAR ALARMS 46 8 1 Standard Fire Zone 46 8 2 Delayed Fire Zone 8 3 Fire Safety Tips 8 4 Minimizing Home Fire Hazards 49 8 5 Home Fire Warning System 50 8 6 Burglar Alarm ees ese ee ee ee ee ee ee ee 50 TESTING AND MAINTENANCE 51 9 1 Burglar Alarm Testing 51 9 2 Fire Alarm Testing 51 9 3 System Maintenance 51 9 4 System Test 52 SYSTEM CHECKLIST anene 53 10 1 Zone Description 53 10 2 Access Codes ee ee ee ee ee 56 10 3 Special Buttons a
8. Overview The LCD screen will guide you with detailed messages AC LIGHT ON AC power OFF Power failure CODE 01 T SELECT ACTION V STATUS LIGHT When Green ON z Zones closed v OFF Zone s open chy EE When the arrows FLASH Exit Delay Ca Ce appear in the a o screen use When Red 7 the arrow buttons ON z Area s armed to scroll through OFF Area s disarmed the current menu ACTION BUTTONS Each button s function is explained in the following sections of the manual Erases current data entry or Saves current data and reverts to the preceding step exits current menu Digiplex LCD Keypad s 7 3 1 AUDITORY FEEDBACK BEEP TONES When you enter information on the keypad the keypad will guide you with beep tones to communicate acceptance or rejection of your entries Confirmation Beep When an operation i e arming disarming is successfully entered or when the system switches to a new status mode the keypad emits an intermittent beep tone BEEP BEEP BEEP BEEP BEEP Rejection Beep When the system reverts to previous status or when an operation is incorrectly entered the keypad emits a tone BEEEEEEEEEEP 3 2 KEYPAD INDICATOR LIGHTS The state of the two colored lights on the keypad see Figure 2 1 page 7 represents a specific condition in your system 3 3 LCD SCREEN The LCD liguid crystal display is a 32 character screen that c
9. button 3 Press one of the following for the system to smv button send a test report to the Security Company pore button call the Security Company s diagnostic software aru button answer the Security Company s diagnostic software po button cancel the communication with Security Company Digiplex LCD Keypad s 45 9 0 FIRE AND BURGLAR ALARMS O eee 9 1 STANDARD FIRE ZONE During a fire alarm the bell siren emits an intermittent sound BEEP BEEP BEEP until silenced or reset If the zone is a Standard Fire Zone the system can immediately send an alert to your Security Company How do I disarm a false alarm 1 Enter your ACCESS CODE on the keypad 2 Call your Security Company guickly to advise them of the false alarm The Fire Zone may reset itself once the problem has A cleared If it does not simultaneously press and hold the and buttons for two seconds 9 2 DELAYED FIRE ZONE During a fire alarm the bell siren will emit an intermittent sound BEEP BEEP BEEP until silenced or reset If the zone is a Delayed Fire Zone there is an automatic delay before the system contacts the Security Company see Figure 8 1 This will prevent unnecessary reporting of false alarms If you are unable to cancel the fire alarm the system will send an alert Call your Security Company to advise them of the false alarm 46 User s Manual What do do if the fire alarm is accidentally t
10. open open zones within that area e Trouble s see section 7 0 if a trouble has occurred e Alarms in Memory see section 5 3 if an alarm has occurred 12 User s Manual 4 0 ARMING ee O When the system is armed the alarm system will respond to any breach in the zones according to the zone s programming For example if someone opens a window that is armed the alarm system will trigger the alarm and can alert your Security Company 4 1 EXIT DELAY TIMER When you arm the system it will start the Exit Delay Timer to provide you with enough time to exit the protected area before the system is armed The Status Light will flash green while the time elapses The timer can be assigned different time limits and the keypad can be programmed to display the time remaining and or beep while the time elapses on the timer Discuss these options with your installer 4 2 REGULAR ARMING This method is used for the everyday arming of the system All zones within the protected area must be closed to arm the system To check the status of the zones in each area refer to section 3 6 Area Status Display Digiplex LCD Keypad s 13 How do Regular Arm the system 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the button If you have access to more than one area press the area s number press the 0 button for all areas or use the Ca and Cv buttons an
11. to lock out access from the keypad for a specified period of time 6 2 ERASING ACCESS CODES To delete existing Access Codes follow the directions in Figure 5 2 on page 29 but press the Lean button in Steps 5 6 and 7 Once the information is erased press the button to save and exit 26 User s Manual 6 3 SysTEM MASTER CODE Default 123456 The System Master Code will give you access to all the features available on your system as well as the ability to add modify or delete any User Access Codes We suggest that you change this code to prevent others from accessing and changing your options without authorization How do I change the System Master Code 1 Enter the current SYSTEM MASTER CODE After Confirmation Beep Access Granted should appear PRG 2 Press the CO button 3 Press the acc button User code Enter a number should appear on LCD screen 4 Enter the numbers 0 and 1 5 Enter a NEW CODE 6 Press the button to exit 6 4 UseR Access CODES Your system supports up to 63 User Access Codes Codes are given a User Number between 02 and 64 User Number 01 is the System Master Code User Access Codes can be programmed with various options that will allow you to control the access to your system The System Master Code and codes with the Masterfeature can program User Access Codes with their User Options and Area Assignment Digiplex LCD Keypad s 27 If the keypad emits a
12. with its receiver or a Fire Loop connection trouble is occurring 7 0 8 Group 8 Clock Loss The time and date have been reset to the default This is the only trouble that we recommend that you correct Clock Loss 8 to Set will appear on the LCD screen after you press the button gra To correct the date and time from Normal Mode enter your ACCESS CODE press the button then follow the instructions below How do reset the time and date TEST 1 Press the button 2 To change the time place the underline under the desired number by using the a button and enter the hour and minutes according to the 24 hour clock i e 9pm is 21 00 3 To change the date place the underline under the desired num ber and enter the correct date according to year month day 4 Press the button to exit Digiplex LCD Keypad s 37 7 1 EVENT RECORD DISPLAY The Event Record Display will record the user initiated actions that occurred in your system as well as any alarms or troubles For example when a valid code is entered the User Access Code and the action taken arm disarm etc is recorded You have the choice of viewing the events in all the areas assigned to your User Access Code or by individual area In either case the most recent event is displayed first see Figure 6 1 gq You will only be able to view the events that occurred in the areas assigned to your User Access Code How do view the Event
13. DIGIPLE X h zadel LISTED yy AS Digiplex LCD Keypad CODE 01 T SELECT ACTION AC STATUS DGP 641 User s Manual RAD 1 0 TABLE OF CONTENTS INTRODUCTION ss ees Es EEN Se ROER SEE 6 WA Legends isi note ntivn SAN a eu Pe ee 6 BASIC OPERATION iii ees ERG EER SEER 7 2 1 Auditory Feedback Beep Tones 8 2 2 Keypad Indicator Lights 8 2 3 ICD SOBO znatni RE RR izk a te i 2 4 User Menu 2 5 Partitioned System 2 6 Area Status Display 11 ARMING sesecicscssec cesceccnscesecnndeccccnnnnecteceactcnezaes 13 3 1 Exit Delay Timer 0 eee ee ee ee ee ee 13 3 2 Regular Arming 3 9 Slay ArMING EE EE EE N 3 4 Instant Arming 3 5 FOGS AMIN OE RE EE RE 3 6 One Touch Buttons 18 3 7 Keyswitch Arming 19 3 8 AUtOSAFMING eise See ERGE EERS RR RS ERG REGS RE Fee AE Re 19 3 9 Bypass Programming 20 DISARMING eise EER EER ERGE EES ARE EER ERGE 23 4 1 Entry Delay Timer 23 4 2 Disarming an Armed System 23 4 3 Alarm Memory Display 25 ACCESS CODES ie is sae ne Ge kani ee ad 26 5 1 Keypad Lock out iese ee ee eee ee ee ee 26 5 2
14. Manual Press option on off Option Description INSTANT off Arm Only feature disabled INSTANT Arm Only feature enabled on Can arm assigned areas but CANNOT disarm ED off Stay amp Instant Arm feature disabled DISPLAY Stay amp Instant Arm feature enabled C6 on Can Stay or Instant Arm the system EVENT off Force Arm feature disabled EVENT Force Arm feature enabled on Can Force Arm the system JEST User Access Code obeys the keypad s on area assignment in a Partitioned System When you enter your User Access Code the keypad will permit access only to areas it controls ai Keypad obeys the User Access Code s area assignment The keypad will permit access to all the areas assigned to the User Access Code regardless which areas the keypad controls Digiplex LCD Keypad s 31 Table 2 Area Assignment In a Partitioned System the system can be divided into four distinct protected areas Programming access to a specific area or areas is called Area Assignment User Access Codes are only able to perform actions arming disarming etc in the area s the code is assigned Press button on off Area Assignment AREA 1 Access to Area 1 on AREA 2 Access to Area 2 C2 on des Access to Area 3 3 on AREA 4 Access to Area 4 C4 on All four buttons off Controls PGMs only if PGMs are programmed by the installer kry When the area s number is
15. OFF the User Access Code does not have access to that protected area 32 User s Manual 7 0 TROUBLE DISPLAY ee If your system is tampered with or experiences problems the Trouble Display will appear on the LCD screen Most of the trouble conditions can be programmed by your installer to be reported directly to your Security Company A keypad will only display troubles that occur in the area s to which it has been assigned Potential troubles have been sorted into eight groups The messages that the LCD screen will display after experiencing the trouble are listed below with a brief explanation of the cause We strongly suggest that you inform your Security Company of the trouble and allow them to service your system How do view the Trouble Display 1 When in Normal Mode see section 3 3 1 and Trouble s TRBL to View appears on the LCD screen 2 Press the rran button The Group heading will appear with the particular trouble causing the problem The Troubles by Group are listed below 3 Use the and Cv buttons to view the specific trouble If your keypad is in Confidential Mode see section 3 3 2 Troubles TRBL to View will not appear on the LCD screen until you enter your User Access Code or press a button depending on how your keypad was programmed Digiplex LCD Keypad s 33 7 0 1 Group 1 System AC Failure The control panel has detected a power failure This means that your
16. Record 1 Enter your ACCESS CODE 2 Press the ET button 3 To view events Press the C 0 button for all areas EAT Press the 1 button for only the First Area EA 2 Press the 25 button for only the Second Area Press the a button for only the Third Area AREA 4 Press the 4 button for only the Fourth Area 4 Use the v button to view subsequent events 5 Press the CLEAR button to exit 38 User s Manual Once you have entered the Event Record Display you can change the order that the Event Record screens see Figure 6 1 appear by pressing the C7 button If you already know the number of the event you want to view press the MEM button and then enter the event s number Figure 6 1 Event Record screens Identification screens FIRST AREA 001 1999 11 25 09 07 Area where the The number of event occurred the event IH The date and time the event occurred Event screens CODE ENTERED CODE 01 ka i The event s that occurred Messages like First Area and Code 01 shown in Figure 6 1 are pre programmed messages that your installer may have customized to suit your system For example First Area could be replaced by Warehouse The Number of the Event may cut off the last few letters of these custom messages For example Warehouse may appear as Wareh001 Digiplex LCD Keypad s 39 8 0 ADDITIONAL FEATURES ee eee 8 1 PROGRAMMABLE OU
17. Rejection Beep once you have completed all the steps you may have chosen an existing User Code or the Master code used to modify or create the code does not have access to the User Options or Area Assignment programmed You grant users access to the features or areas by turning ON or OFF the number corresponding to the option or area The option is considered ON when the number appears within the brackets You turn options ON and OFF by pressing the number buttons on the keypad see example Figure 5 1 Figure 5 1 Example of Activating Options All options are OFF The user does not have access to the options Press the 42 button 00 USER OPTIONS Denok 7 Option 4 is ON The user now has access to option 4 Press the 42 button again GOT USER OPTIONS eek Uke T 001 USER OPTiaNs Option 4 is now OFF The user no Dece T longer has access to option 4 28 User s Manual 1 2 3 4 8 7 Figure 5 2 Programming User Access Codes PARADOX FARILY 1999 11 25 10 36 v CODE 01 T SELECT action V v ACCESS CODE 1 IACCITO PROGRANV v USER NUNBERI 117 ENTER A NUMBERS v USER CODE 00 T Do not press 60769 v 000 USER OPTIONS EET T Do not press Ente v 000 ASSIGN AREA Enter your ACCESS CODE System Master Code or User Access Code with Master feature only Press Co to ente
18. SYSTEM TEST Speak to your installer before conducting a system test since the system must be programmed to respond to the test instructions It is normally recommended that you conduct the system test once a week but contact your installer for instructions concerning your particular system How do conduct the system test 1 Call Security Company to advise them that you are testing the system 2 Enter your ACCESS CODE 3 Press the button The system will test all its connections and can send a report to your Security Company If the system detects a problem the Trouble Display will show on the LCD screen see section 7 0 Call your installer for repairs 52 User s Manual 11 0 SYSTEM CHECKLIST ee ee Important Keep this information in a secure location 11 1 ZONE DESCRIPTION Is this a Partitioned System Yes No Area 1 Area 2 Area 3 Area 4 Place a v indicate the options and area s enabled for that zone if any Zone and Area Description 1 2 3 4 Entry Byp Stay Force 24Hr Delay 01 02 03 04 05 06 07 08 Digiplex LCD Keypad s 53 Zone and Area Entry Description 1234 Delay TPT CT I eT IE A PATA I ATA 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Byp Stay Force 24Hr
19. T be displayed e The Indicator Lights will not illuminate Depending on how your keypad was programmed by the installer you must either press a button or enter your User Access Code to illuminate the Indicator Lights and activate Normal Mode Digiplex LCD Keypad s 9 3 4 USER MENU Once you enter your User Access Code and are granted access to the system the LCD screen will display the User Menu as shown in Figure 2 3 From this menu you can access various features and other menus Depending on the User Options programmed on your User Access Code you will have access to some or all of the features and menus in the User Menu Press the desired Action Button see Figure 2 1 page 7 or scroll through the menu by using the Ca and v buttons on the right of the keypad and press the button Once you have completed an action i e arming disarming etc the LCD screen will return to Normal Mode Figure 2 3 User Menu PARADOX FARILY Normal Mode 1999 11 25 09 00 y Enter your access code If the USER ACCESS CODE codeis valid the LCD screen will briefly display ACCESS i GRANT ED and proceed CODE DI dy gerer Berig STEVE 10 User s Manual 3 4 1 Multiple action The Multiple action feature permits you to complete more than one action after entering the User Menu If your installer has enabled this feature the LCD screen will return to the User Menu after each action so you may perform another acti
20. TPUTS PGMs Your Digiplex system includes five programmable outputs PGMs that can be programmed by your installer A PGM triggers when a predetermined event or series of events occurs in your system The PGMs can be programmed to reset smoke alarms turn on light switches open or close garage doors and much more Ask your installer about this useful feature 8 2 KEYPAD SETTINGS You can modify the keypad settings to suit your needs see Figure 7 1 1 Scrolling Speed is how long the messages stay on the screen before moving to the next message 2 Backlight refers to the illumination behind the buttons and LCD screen 3 Contrast refers to how dark or pale characters on the screen will appear 40 User s Manual Figure 7 1 Modifying LCD screen settings Enter your ACCESS CODE 4 EE Press 0 6 AREA 1 AREA 2 AREA 3 Press 1 Press 2 Press 3 Scrolling Speed choose a number from zero to ten ten is the slowest Backlight choose a number from zero to seven seven is the brightest Contrast choose a number from zero to four four has the most contrast v Cy Ca To increase or decrease the numbers l Press o Press to exit Press CYD to move to the next setting Digiplex LCD Keypad s 41 8 3 SET TIME amp DATE If the wrong time and or date are displayed on the Normal Mode sc
21. ammed by the installer e Your User Access Code must be programmed to enable the Bypass option e Your User Access Code must have access to the zone s Area Assignment A Fire Zones cannot be bypassed 4 9 1 Zone Bypass How do bypass a zone 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the se button 3 Enter the zone number or use the Ca and C v buttons and press ave once the zone you want to bypass appears If zone bypassed does not appear on the screen and the key pad emits the Rejection Beep the zone may not have the bypass feature enabled 4 Press the button to exit Digiplex LCD Keypad s 21 4 9 2 Bypass Recall Bypass Recall reinstates all the zones that were bypassed the last time the system was armed How do activate Bypass Recall 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press the button 3 Press the men button Zones bypassed during the last time the system was armed are bypassed 4 Press the button to exit kr If you have a Partitioned System only the zones in the area s assigned to your User Access Code will be affected Use the Ca and C v buttons if you want to verify which zones were bypassed the last time the system was armed after you press the mem button Step 3 Bypassed or Zone Normal will appear below the zones If you
22. cume Fire or CD 8 e gt 60 User s Manual EVENT C7 Event Record Display and if alarm is Audible Audible Audible PGMs PGM When this occurs This is activated 1 11 4 OTHER INFORMATION Installed By Date Service provided by Tel Monitoring Station Tel Your account number is Alarm transformer location on circuit Location of Telephone Connections Digiplex LCD Keypad s 61 Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party ca
23. d press when the area you want to arm appears After the Confirmation Beep Regular Arming should appear on the LCD screen and the exit delay timer will begin the countdown to arming kry If enabled by the installer the One Touch Buttons section 4 6 or a keyswitch section 4 7 can also be used to arm the area 4 3 STAY ARMING Stay Arming will partially arm your system to permit you to remain in the protected area Based on your instructions your installer will program specific zones as Stay Zones These zones will not arm when you Stay Arm For example you can arm your doors and windows at home without arming the motion detectors so you will be protected while you sleep Only User Access Codes with the Stay and Instant Arm option enabled can Stay Arm the system Also see section 4 8 Auto Arming for another everyday arming option 14 User s Manual 4 3 1 Stay Arming with Delay Stay Arming with Delay functions like Stay Arming except the installer can program armed zones with an Entry Delay Timer lf these zones are accidently triggered the timer will start to allow you time to disarm the area s How do I Stay Arm 1 Enter your ACCESS CODE After Confirmation Beep Access Granted should appear 2 Press button If you have access to more than one area press the area s number eae the 0 button for all areas or use the Ca and Cv buttons and press ENTEB when the area you want to Stay dn appears
24. mper switch on a module ROM Check Error The control panel registers a memory error in a module TLM Trouble A module is unable to access the telephone line Fail to Communicate A module has failed to communicate with the Security Company Printer Trouble The control panel registers a problem with the printer Check printer for problems paper jam no paper no power etc before calling installer Digiplex LCD Keypad s 35 AC Failure Module power failure Battery Failure Module s battery is disconnected needs to be recharged or replaced Supply Output Module has exceeded current limits 7 0 4 Group 4 Bus Troubles Missing Keypad A keypad is no longer communicating with the control panel Missing Module A device no longer communicating with the control panel General Failure No communication between devices and the control panel Bus Overload Too many devices are connected on the Bus Bus Communication Error The Bus is having difficulty communicating with the devices and the control panel 7 0 5 Group 5 Zone Tamper The zone or zones that were tampered with will be displayed on the LCD screen 36 User s Manual 7 0 6 Group 6 Zone Low Battery If a wireless device s battery needs to be replaced the zone that it is assigned to will be displayed on the LCD screen Also the light on the device will flash to indicate this trouble 7 0 7 Group 7 Zone Fault A wireless device is no longer communicating
25. nd Features 60 10 4 Other Information 2 0 INTRODUCTION O eee Your Digiplex Security System is an advanced technology security system that will provide you with reliable security protection and powerful features that are easy to use The elegant and user friendly Digiplex LCD Keypad will allow you easy access to your security system s functions and information at the touch of a button The 32 character LCD screen will display messages and menus to guide you through the system s operations Your installer can even customize the messages for your home or business Since you will communicate your instructions to your system through the keypad please read this manual carefully and have your installer explain basic system operation 2 1 LEGEND A Indicates a warning or an important note Indicates useful information or tip WORD NUMBER Indicates information that must be entered on the keypad Italics Indicates references to features options or sections 6 User s Manual 3 0 BASIC OPERATION eee Everything you need to know about your security system is clearly displayed on the large LCD screen The menus and the prompt on the LCD screen provide simple step by step instructions on how to use your system and display what is occurring in your system The following sections will introduce you to the roles of the buttons the lights and messages on your Digiplex LCD Keypad Figure 2 1 Basic
26. ommunicates messages instructions and the status of your system The backlight contrast and scrolling speed are adjustable see section 8 2 Your installer can customize many of the messages to suit your needs 8 User s Manual 3 3 1 Normal Mode When no actions are being performed on the keypad the keypad will remain in Normal Mode as shown in Figure 2 2 on page 9 and will automatically display The current status of the zones for every area the keypad is assigned The Alarm Memory Display see section 5 3 if any alarms have occurred The Trouble Display see section 7 0 if any troubles are occurring The current state of the Indicator Lights Figure 2 2 Normal and Confidential Mode In Normal Mode the LCD screen will display Paradox Family and the time amp date as PARADOX FAMILI well as scroll the system zone and trouble 1999 11 25 03 00 status for every area to which the keypad is assigned In Confidential Mode the LCD screen will only display Confidential and the time amp CONFIDENTIAL date as shown Depending on how your 1999 11 25 09 99 keypad was programmed Normal Mode will only appear once a button is pressed or a User Access Code is entered 3 3 2 Confidential Mode The installer can program keypads not to display the status of your system automatically by changing the LCD screen to Confidential Mode In Confidential Mode The zones and status messages will NO
27. on without having to re enter your User Access Code Press the button to exit the User Menu 3 5 PARTITIONED SYSTEM Your installer can design your system to recognize up to four separate protected areas A separated system is called a Partitioned System which can be useful in situations where shared security systems are more practical For example a company that has both an office area and a warehouse area can arm and disarm each area separately and control the access to each area Therefore one person may have access to only one area whereas another person may have access to all areas Access to the areas is determined by the User Access Code 3 6 AREA STATUS DISPLAY In Area Status Display you will be able to see the status of the areas in a Partitioned System see section 3 5 for the area s the keypad is assigned If your LCD screen is in Confidential Mode see section 3 3 2 you must first press a button or enter your User Access Code to activate Normal Mode depending on how your keypad is programmed Digiplex LCD Keypad s 11 How do I see the status of the zones 1 Enter ACCESS CODE then press the button corresponding to the area CY Area 1 8 Area 3 AREA 4 AREA 2 C2 Area 2 C4 Area 4 2 Press CLEAR to exit In Area Status Display the following will scroll on the LCD screen e ready if all zones in the selected area are closed not ready if zones in the selected area are
28. ould be installed outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements 9 6 BURGLAR ALARM If your armed system is breached the burglar alarm devices specific to your system will be triggered If your keypad is in Normal Mode e The Status Light may flash red e In Alarm will appear on LCD screen Bell or siren may be activated In case of a burglar alarm leave the premises and A call your Security Company from a safe place 50 User s Manual 10 0 TESTING AND MAINTENANCE 10 1 BURGLAR ALARM TESTING Two people are needed to complete this test One person will watch the LCD screen on the keypad while the other person walks around the protected area and open the zones i e open the doors and window that are protected walk in the path of the motion detectors etc The LCD screen will display the opened zones If a zone does not register contact your installer Your installer will provide details on the best way to test your system 10 2 FIRE ALARM TESTING Do NOT use an open flame or burning materials to test your fire detection devices Your installer will provide details on the best way to test your system 10 3 SYSTEM MAINTENANCE Under normal use your system requires no maintenance other than regular testing We recommend that your installer change the battery every three years Digiplex LCD Keypad s 51 10 4
29. outside 3 Practice the escape plan freguently 4 Plan two ways to escape from every room if possible 5 Practice feeling the way out with eyes closed 6 Tell everyone never to stand up during a fire always crawl under the smoke and keep mouths covered 7 Instruct everyone never to return to a burning building for any reason it may cost them their life 8 Check smoke alarms regularly working smoke alarms dramatically increase everyone s chances of surviving a fire 9 4 MINIMIZING HOME FIRE HAZARDS How can you avoid the three most common causes of fires at home 1 Never leave cooking food unattended It s also the leading cause of fire injuries Cooking fires often result from unattended cooking and human error rather than mechanical failure 2 Stay alert when smoking Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resistant bedding and upholstered furniture are significant fire deterrents 3 Maintain your heating system Heating is the second leading cause of residential fires However heating fires are a larger problem in single family homes than in apartments Unlike apartments the heating systems in single family homes are often not professionally maintained Digiplex LCD Keypad s 49 9 5 HOME FIRE WARNING SYSTEM Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors sh
30. r Programming Menu From Programming Menu press ce Choose the 2 digit User Number you want to program or press C v to scroll the list of codes Code Empty will appear for an unused code Press once desired code appears Enter a User Code If you do not want to change an existing one press _a_ to reach the User Options screen Program the User Options from Table 1 Once the options are programmed press A to reach the Area Assignment screen Program Area Assignment from Table 2 Once the area s are programmed press CYD to return to the User Options screen or press to save and exit Digiplex LCD Keypad s 29 Table 1 User Options Options on the User Access Codes that activate access to features Press option on off Option Description off 25 off Master feature disabled EAL AREA 2 Master feature enabled 1 2 CD op si Modifies User Code only EA EA sih n 25 Full Master feature enabled Create or modify other User Codes User Options and Area Assignment according to its own User Options and Area Assignment 35 of Duress feature disabled AREA 3 Duress feature enabled 3 C3 on Can arm disarm and send a silent alarm to the Security Company For use when someone forces you to arm or disarm areas 4 off Bypass feature disabled AREA 4 on Bypass feature enabled Can deactivate zones using the Bypass feature 30 User s
31. reen you can reset them How do reset the time and date 1 Press the button TEST 2 Press the button 3 To change the time place the underline under the number you want to change by using the a button and enter the hour and minutes according to a 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 4 To change the date place the underline under the number you want to change and enter the correct date according to year month day 5 Press the ENTER button to exit 8 4 PROGRAMMING CHIME ZONES You can program the keypads to emit a rapid intermittent beep whenever designated zones are opened or only when opened between certain hours These zones are referred to as Chime Zones Your installer can program your Chimed zones to also beep upon closure 42 User s Manual Figure 7 2 Programming Chime Zones Enter your ACCESS CODE v Press CHIME Press C1D to Chime a zone Press 2 to set the time period zone s will beep when opened Enter the number of the zone you want to Chime or use Ca and Cy to scroll the list Enter the time that you want all Chimed zones to start beeping when opened HH MM t Press to Chime or Unchime the zone when it appears on the screen Enter the time you want all Chimed zones to stop beeping when opened HH MM L Pres
32. riggered 1 Press the button within 30 seconds of the alarm 2 Clear the problem from the area 3 If problem remains after 90 seconds the alarm will sound again Press CLeaf again The system will delay reporting the alert for another 30 seconds The Fire Zone may reset itself once the smoke has A cleared If it does not simultaneously press and hold the Gear and buttons for two seconds or speak to your installer Digiplex LCD Keypad s 47 Figure 8 1 Delayed Fire Zone Delayed Fire Zone triggered v Bell siren activated Transmission of the report delayed for 30 seconds Delay timer may appear on LCD screen v Has the problem been corrected YeS within the 30 second delay y No Yes Bell siren continues Has a second Delayed Fire Zone triggered within the 30 gt ee second delay Company y No Has been pressed within No the 30 second delay 4 Yes Bell siren silenced Transmission of the Fire Alert report delayed an additional 90 seconds Delay timer may appear on the LCD screen v No Problem corrected within the 90 second delay v Yes END Alarm disabled 48 User s Manual 9 3 FIRE SAFETY TIPS How should you prepare in case of a fire in your home or business 1 Remind everyone to escape first then call for help 2 Develop a fire escape plan and designate a meeting place
33. s to save v Press to exit Digiplex LCD Keypad s 43 8 5 PANIC ALARMS Your system can be programmed to send an alarm to your Security Company to request help from the police a medical facility the fire department or anyone you wish when you press a pre determined combination of buttons Ask your installer about programming these features in your system Emergency Panic EAT AREA Press amp hold the CTO and 3 buttons simultaneously for two seconds to generate an alarm The alarm can be programmed by the installer to be either silent or audible according to your preference Auxiliary Panic AREA 4 DISPLAY Press amp hold the 4 and 6 buttons simultaneously for two seconds to generate an alarm The alarm can be programmed by the installer to be either silent or audible according to your preference Fire Panic EVENT CHIME Press amp hold the C 7 gt and C 9 buttons simultaneously for two seconds to generate an alarm The alarm can be programmed by the installer to be either silent or audible according to your preference 44 User s Manual 8 6 QUICK FUNCTION BUTTONS You will only need to use the Quick Function Buttons upon your installer or Security Company s request Only the System Master Code or User Access Codes with the Master feature enabled will be able to access these functions How do access the Quick Function Buttons 1 Enter your ACCESS CODE PRG 2 Press the Co
34. used by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold R D o x2 T Y s Y s T E M s http www paradox ca PRINTED IN CANADA 06 99 K641EU 01
35. want to unbypass a zone or vice versa press the button 22 User s Manual 5 0 DISARMING ee When the system is disarmed the alarm system deactivates the zones so the alarm will not be triggered if zones are breached Any user can disarm the system unless their code has been assigned the Arm Only option 5 1 ENTRY DELAY TIMER Your installer will program designated entry points i e the front door with an entry delay This delay will allow you enough time to enter your code to disarm the system before the alarm is triggered 5 2 DISARMING AN ARMED SYSTEM You can only disarm the area to which your User Access Code is assigned User Access Codes with the Arm Only option cannot disarm area s Digiplex LCD Keypad s 23 How do disarm the system If you are disarming a Stay or Instant Armed area go to step 2 1 Enter through a designated entry The keypad will beep and begin the Entry Delay Timer 2 Enter your ACCESS CODE 3 Press the button If you have access to more than one area press the area s number press the 0 button for all areas or scroll and press when the area you want to disarm appears After Confirmation Beep Success Disarm should appear on LCD screen try If enabled by the installer a One Touch Button section 4 6 or a keyswitch section 4 7 can also be used to disarm the area How do disarm an accidentally triggered system 1 Enter your ACCESS CODE 2 Call
36. y see section 3 6 for a Partitioned System see section 3 5 Press and hold EAT AREA2 12 2 To view each protected area 35 as in a Partitioned System Your installer can also program your system to respond to certain features with just a touch of a button You will then have access to the following features without using your User Access Code by pressing and holding the desired button Press and hold anu To Regular Arm 55 To Instant Arm say To Stay Arm ai To change keypad settings fort To Force Arm 75 To view Event Record Display For Bypass Programming To Disarm a Stay or Instant armed area s For more information on these features please refer to their sections 18 User s Manual 4 7 KEYSWITCH ARMING Your installer can add a keyswitch to arm and disarm your system The keyswitch can be programmed to Regular Stay Force or Instant Arm and Disarm a specific area The keyswitch will also be programmed by the installer to function as a Maintained or Momentary keyswitch 4 7 1 Maintained Keyswitch To arm the system place in the on position To disarm the system place in the off position 4 7 2 Momentary keyswitch To arm the system place in the on position briefly then place it back in the off position Repeating this process will disarm the system 4 8 AUTO ARMING Your installer can program your system to allow you to arm your system automatically if specific conditions occur
37. your Security Company quickly to advise them of the false alarm 24 User s Manual 5 3 ALARM MEMORY DISPLAY Your system will record all the alarms that occurred during the last armed period If an alarm was triggered the keypad will display Alarms in Memory In case of a burglar alarm leave the premises and A call your Security Company from a safe place How do view the list of the alarms that occurred When an alarm has occurred the LCD screen will display Alarms in Memory MEM to View 1 Press the we button Each zone whose alarm was triggered will appear below Alarm in 2 Press the button to exit the Alarm Memory Display gq he Zones in alarm will remain in the Alarm Memory until the next time that area is armed Digiplex LCD Keypad s 25 6 0 ACCESS CODES Access Codes allow access the system These codes can be programmed to permit access to all or some features and areas The installer will program User Access Codes to be four digits six digits or variable from one to six digits in length Each digit can be any value between zero and nine 11 the installer programmed your system to accept a variable code length you may have to press the button after entering their User Access Code Only the System Master Code cannot be less than 4 digits 6 1 KEYPAD LOCK OUT If a consecutive number of invalid codes are entered on the keypad the installer can program the system