1. 420 283 090 770 service and technical support tel 420 774 715 012 fax 420 283 090 771 oz a sapo y This electronically controlled system is among the best on the hydrotherapy market The Lux system is electronically controlled including electronically controlled water massage control of pump revolutions is a unique function of this system which gives you a maximum experience from the bath and maximum therapeutic effect The TM62 controller has the following functions functions are optional according to the system configuration Hydro water massage Air massage eventually Hydro and Air combined Pulsation Electronically controlled compressor Airpool and pump Whirlpool Disinfectant backwash system StreamClean with automatic filling filling is optional Illumination LED halogen Chromotherapy Water heating e Electronic control with display gives you possibility to set actual time massage time and water temperature Description of controller buttons Button description function after pressing the button Bath filled with water between the Fienie numbers of hours and minutes only the Bath without water both dots upper and higher upper dot blinks the lower dot is on all blink between the numbers of hours and minutes the time Illumination halogen LED CoolLight StreamClean backwash 1 press turn illumination on The long press starts the security count from 5 sec to 2
2. no massage is on 1 The long press of the appropriate massage button reverts into the timer mode With button 2 we can add 5 more minutes 3 With button 4 we can take away 1 minute The long press will remember the set value After switching the massage on the time of massage is taken away from set value and when it approaches zero massage is automatically switched off
3. press turn illumination off zero when it is confirmed during this time by the short press the disinfectant system with backwash of Chromotherapy hosepipes is activated 1 Press the control button activation of chromotherapy from disabled Cycle after long pressing the button mode to start up the 1 The disinfectant solution pump runs for 30s chromotherapy into cyclical 2 After 5s from the start of the disinfectant colour change mode solution pump the pressure water valve is 2 Second press stops the cycle at the enabled for 25s and the whole system is being desired colour backwashed with a mixture of water and 3 Third press switches the disinfectant solution chromotherapy off 3 The pressure water and the disinfectant solution pump are turned off water flows freely from Long press can enter the last chosen the nozzles into the bath and the disinfectant colour solution works for 60s If both lights are present in the system 4 The pressure water is turned on for 40s It than short press controlles the halogen rinses the system thoroughly with clean water light and long press the chromotherapy 5 The pressure water is turned off water flows There is no shortcut to last chosen freely from the nozzles for 60s colour The drying compressor is turned on for 60s only at system Combipool the system is dry and ready to be used Button description function after pressing the button Figure Bath f
4. Display description Activated mode Bath filled with water Empty bath All functions off Indication of water presence in the bath Actual time one dot flashing Indication of water absence in the bath Actual time both dots flashing between hours and minutes Filling Counting time since the start of filling the bath with water Drying Drying time countdown 20 0s Letter H Hygiene and the cycle countdown 4 Disinfectant min 10s 0s are shown The Flashing letter H backwash means insufficient disinfectant solution it is StreamClean necessary to refill the disinfectant solution into the disinfectant tank Enabled massage Actual time bath water temperature run time of the first enabled function are rotated every 3 seconds Heating enabled does not warm At the displayed temperature of the water the dot slowly blinks behind the first number the temperature of the water in the bath is higher than the temperature set up on the thermoregulator or the hydro massage is not switched on Heating enabled warms At the displayed temperature of the water the dot quickly blinks behind the first number Special notice Automatic Drying cycle of the airpool system pipe system will automatically start aprox 21min after last drying press of any button or after the last run function has terminated and there is no water in the bath tub cycle The maximum
5. bath time is set to aprox 21min This is also a recommended length of a massage Norte After that you have to turn the massage on again by pressing the appropriate button If the hydromassage has been running for all 21 min there must be at least 10 min break for cooling the pump before another use of the hydromassage In case of a non standard behaviour of the electronic controller press and hold and press Soft reset then release both buttons If the problem has not been solved it is necessary to unplug the power to the bath and after a while plug it in again iS In case the Soft reset has not helped to solve the non standard behaviour of the electronic aaa controller disconnect the power to the bath and reconnect it after a while Software After starting the supply and after the reset the software version is shown on the display for 1 version sec The form is following X xx X is the version S Standard xx is the version number automatic filling of the bath is active only if the system includes Disinfectant backwash StreamClean SaPHO HYDRO alR User s manual for operating hydrotherapeutic massage system Lux Whirlpool Airpool Combipool Software version 11 SAPHO Hydro amp Air s r o M lnick 87 250 65 L beznice Manufacture and sale of hydrotherapeutic systems www sapho hydroandair cz www hydromasaze cz e mail info hydromasaze cz tel 420 283 090 770 service and technical support tel
6. illed with water between the numbers of hours and minutes only the upper dot blinks the lower dot is on all the time Bath without water both dots upper and higher blink between the numbers of hours and minutes Water heating Turn on off 1 short press turn water heating on water heating works only when hydro massage is turned on 2 short press turn water heating off Central system shut down Press for a long time to turn off all functions Press for a long time activates the mode for the set of heating temperature see below Setting the temperature 1 long press in the mode of real time when massage systems are turned off to change the set temperature of the thermostat the set value is flashing The temperature can be changed by pressing gt and buttons 2 long press confirms the choice and remembers the chosen value The default value is set to 36 C it is always set up after the reset or switching the net power supply of the bath off Hydro massage Whirlpool massage 1 short press turn on water massage with the maximum output pump speed 2 short press turn on rolling water massage sinusoidal cycling from minimum to maximum 3 short press turn off the water massage The intensity of the massage speed of the pump can be regulated by the buttons gt Automatic Bath filling 1 short press enables the automatic bath filling with water at the temperature se
7. t on the thermostat and to the height of a water level sensor approximately at the lower edge of the safety overflow Display shows the time of filling The maximum filling time is set to 20min as a safety measure against overflowing If you need to add water into an already filled bath it necessary to use bath taps or shower Airpool air massage 1 press turn on air massage with the middle speed of blower 2 press turn on rolling air massage sinusoidal cycling from minimum to maximum 3 press turn off air massage The intensity of the massage revolutions of blower can be regulated with F buttons Drying 1 press enables drying of air massage distribution system with slow start of blowers The drying time is set to 20s The time of drying is showed on the display Repressing the button again turns off the drying earlier Setting revolutions of compressor or pump Increases Decreases intensity of water or air massage If both the water and air massage are running at the same time sets the last used function Setting actual time in the regime of image of the real time no massage is on 1 long press button adjust the hours 2 buttons can adjust the value 3 long press button will save the value into the memory The set of minutes is analogical but it is done with button hours are flashing to The set of lasting of the massage in the regime of image of the real time