Home

Installation and User`s Manual

image

Contents

1. coming in through the air combustion control 1 page 6 7 Let the fire burn until it creates the first embers Note Thin and dry pieces of wood should be used for lighting The model 480 NM RS never should be used with the the air combustion control 2 totally closed Normal Procedure After lighting 1 Open the door slowly spread the embers equally over the base of the stove 2 Place logs of approximately 1kg each horizontally Don t overload the appliance and check the recommended maximum load for your model on the chart for appliance characteristics 7 3 Close the door 4 Choose a position on the air combustion control to achieve a regular lasting burn avoid an excessive burn Note o You should only reload the stove when the previous load has been completely consumed Dont overload your stove e The paint coating the stove was not subjected to cooking in an oven so it will harden with the first time used Also why on first use emission of fumes and odors may occur Avoid inhalation and ventilate the surrounding space 16 adr Warning the appliance was not designed to work with the door open Do not open the door of your appliance suddenly this could overpressure the combustion chamber causing smoke or even flames to be released into the room Warning if you notice any adverse atmospheric conditions which affect the draw of the smoke it is advisable not to use the appliance Warning for well insula
2. of non combustible materials If the area where the equipment will be installed no longer fulfills this requirement appropriate measures should be taken for example a plate load distribution Flame resistant material should be placed high temperatures across the back of the stove with a minimum thickness of 20 cm It should be noted that the stove should never be physically restrained in any direction once should insure themselves the phenomena of thermal expansion that the materials will be subjected It is considered prudent that the clearance for expansion is approximately 5 mm to each side of the fireplace 10 adr Should never obstruct the vents It is also desirable that in homes with good insulation and Or possessing contiguous spaces with exhaustion is placed a grill vent connected to the outside of the house with about 100 cm2 Thus supplies the surrounding space with a good supply of oxygen in order not to exhaust and air masses moving in the right direction As for the air intake grilles must be taken into account that must be positioned so as not to be easy clogging When simultaneous with other heating appliances operating shall ensure the existence of sufficient oxygen Tubing You will only get the maximum efficiency from your appliance if the chimney is also efficient Before installing your ADF appliance check that the chimney is clean and unobstructed If you have any difficulties ask a professional to examine the chim
3. the fan chamber and the fans This operation should be carried out by a qualified professional Over time you may think that your appliance needs painting In this case paint the appliance using a high temperature spray paint provided by ADF You should only paint the appliance when it is completely cold Before painting carefully cover any nearby areas that you dont want to paint glass and hearth and follow the instructions on the paint can Clean the chimney and the neck of the chimney remove flame deflector at least once a year If necessary ask a qualified professional to do the job Periodically check and replace where necessary the sealing cord around the door Only use replacement pieces recommended by ADF This ADF appliance was designed in accordance with existing legislation so as to minimise eventual risks of a fire in the chimney However should this occur 1 Remain calm and check that conditions are safe enough for you to close down the appliance Completely close the door of the stove Completely close the admission of air and the flue The appliance should then go out by itself due to lack of oxygen If the area is unsafe then move away from the danger and immediately call the fire services for help using the European emergency number Before using the appliance again ask a qualified professional to carry out an inspection of the chimney 18 a adF The manufacturer of ADF stoves hereby decl
4. ares that all models described above are in compliance with general safety requirements However it cannot be held responsible if alterations have been made to the product without due written authorization from the Manufacturer Antonino Dias Fernandes Lda Zona Industrial da Relvinha Adress Sarzedo Apartado 55 3304 909 Arganil Solid fuel li NP EN 60335 2 102 Applicable regulations EN 13240 2001 CATIM Centro de Apoio Tecnol gico Industria Responsible entity for testing Metalomec nica Rua dos Pl tanos 197 Porto 19 8 Troubleshooting If you follow all the instructions described in this manual you shouldn t have any problems in enjoying your stove to the full However if you do need to seek technical assistance first check that a adr All the instructions provided in this manual have been followed II If there have been any changes around the appliance which could have resulted in the problem HI If the problem corresponds to any of the following points Problem s Possible Cause s Correction s Flue regulator is closed Damp or green wood Dirty or blocked chimney Burning poorly Damp or green wood and inefficiently Burning too fast The fire goes out Fan does not work Glass dirty Dirty or blocked chimney Not enough wood Wood is too light Door not properly adjusted Sealing cord worn out Damp or green wood Th
5. ature it is subject to different regulations which should be taken into account and complied with The need to gain access for the maintenance of the tubing must be taken into account therefore the fixing of the tubing should not be permanent adr The chimney must be at least 0 6m from the highest part of the roof In any other area which is not the highest point it should be at least 1 m above the roof Your chimney should be cleaned at least once a season adr Note e The equipment must not be cemented its surroundings under any circumstances leave enough space to be able to expand and contract freely typically 5mm around the perimeter space Desirable to connect at least one of the vents A q 8 e Should position the air inlet louvers so as not to be blocked e When installing the appliance all local regulations including those relating to national and european standards must be respected anti condensation system 1 Step Fit the smaller part of the pipe male in the hole of the equipment and in the other extremity of the pipe the diameter will be bigger female 2 Step If you want to dock installation accessories such as hat the use the bigger diameter female you must use an union to convert the diameter 13 a adF SOME OF THE MOST IMPORTANT CURRENT REGULATIONS e EN13384 1 2003 Chimneys Thermal and Fluid dynamic calculation methods Parte 1 EN 2006 Chimn
6. ce from i mm combustible materials Recommended fuel Width Flue Weight Height mm Depth mm outlet kg mm mm adr Warnings A wood burning stove is by nature an appliance which operates at high temperatures This means paying attention to potential situations of risk and making sure they are avoided With this in mind please pay particular attention a to children whose natural curiosity may put them at risk and therefore should be kept well away from any heating appliance The appliance you have just purchased must be installed by a professional to ensure it s proper and safe functioning Remember that all current safety regulations must be complied with The appliance must be installed in such a way as to make maintenance easy The incorrect installation of the appliance could cause serious damage to the appliance and put people and property at risk Before installing your appliance make sure that The floor is not inflammable The floor has adequate resistance capacity The room where the appliance is to be installed is well ventilated Safety distances from combustible materials are respected as mentioned in this manual e Your appliance must be installed in a non permanent way making access to it easy to ensure the general maintenance of both the appliance and chimney e The appliance must in no circumstances be cemented into its location adr Important Recomendations It is recommended that yo
7. conditions of installation handling and maintenance described in this manual were strictly complied with and no undue use or alterations or modifications to the appliance have taken place IV The warranty is limited to the replacement repair by ADF or its agent the admittedly damaged components and excludes any other sort of coverage or indemnity 21 adr 10 Warranty Certificate Qadir fabricante equipamentos t rmicos Warranty Certificate Name Adress of the importer Model Serial No Sold to Adress Zip Code Stamp and Signature AGENT Client Signature Note The guarantee covers the exchange and or restoration by ADF or its agent of the components that are acknowledged as damaged and excludes any other type of cover or compensation such as costs of removal and reinstallation of the appliance ATTENTION On being delivered check the state of the appliance The guarantee only covers damage caused during transport if notification has been given and marked on the document acknowledging reception of the appliance within a period of 48 hours 22 adf 2 acr fabricante de equipamentos t rmicos www adf pt adf adf pt 24
8. d If you have any difficulties ask a professional to examine the chimney Both the height of the chimney as well as breaks in pressure in the chimneys are directly related to your gt drawing so the line must have the most straight as possible or failing which trajectory never suffer higher angular deviation at 45 to the vertical It is also ideal that the construction of the conduct of the flue passes through the interior of the building thus ensuring better insulation and so avoid unwanted condensation originated by temperature differentials which sooner or later may damage the system Not suitable are the flue ducts from the outside and without insulation The chimneys must have individual outputs flues and is totally inadvisable grouping several chimneys in collective behaviors The outlet smoke pipes must have constant section from the output of the stove to exhaust venting to the atmosphere Recommended for the exits for fumes of fireplaces dimensions are defined in the Technical data table The hat of the chimney must not possess an obstructive manner towards the currents of outer air ie it must allow air to enter through the side exit can access the opposite side causing no air currents descendants chap u da chamin remate tubo duplo isolado tubo saida de fumos recuperador Encasing the fireplace The appliance must be installed in areas that have adequate bearing capacity and are composed
9. dgeable of the technical characteristics of the elements 14 a adF 6 Using the Equipment 820 NM RS Ignition LIGHTING FROM COLD 1 When using this appliance for the first time or after a prolonged break it is extremely important to carefully examine the chimney and check that it is clean and unobstructed If you have any problems ask a professional to carry out an inspection 2 The appliance was designed to function intermittently with intervals for loading wood of between 45 to 60 min 3 Completely open the air combustion control At the bottom of the stove place a product that burns easily firelighters pine needles pine cones or other 4 On the top of this place small logs stacked horizontally around 1Kg 5 Leave the door slightly open with a gap of 2cm This will allow air to get in and help the fire get started more quickly and efficiently Keep the air combustion control completely open 6 After 5 to 10 minutes close the door reduce the amount of air coming in through the air combustion control 7 Let the fire burn until it creates the first embers Note Thin and dry pieces of wood should be used for lighting Normal Procedure After lighting 1 Open the door slowly spread the embers equally over the base of the stove 2 Place logs of approximately 1kg each horizontally Don t overload the appliance and check the recommended maximum load for your model on the chart for appliance characteristic
10. e stove hasn t heated up sufficiently Fuction temperature not achived yet Energy Break Damp or green wood Open flue regulator Use drier wood Clean chimney Use drier wood Clean chimney Fill the stove with thicker wood Readjust the door Replace the cord Use drier wood Heat the stove well by opening the main air regulator put more wood verify connections Slightly open the air regulator mechanism Use drier wood If the problem still persists then contact us through our agents or directly so that our technical assistance services can help resolve the problem 20 a adF 9 Warranty conditions Warranty We provide five years of guarantee with your ADF appliance against manufacturing defects Exclusions Glass refractory Cord Tape Are not covered under warranty because they are oversized for use temperatures 700 800 C and its use is beyond the control of Manufacturer Flame deflector grill Ash are not covered by the guarantee because they are subject to wear and use which is outside the control of the manufacturer quality of firewood and operating systems Conditions of Guarantee I The appliance is within the time limits described above the beginning of this period of guarantee having begun on the date the appliance was purchased II Complaint must be presented to and validated by one of our agents and evaluated by ADF HI The
11. eys for appliances EN1857 2003 Chimneys Components flue liners EN1457 1999 Clay ceramic flue liners Requirements and test methods EN 1806 2006 Chimneys clay ceramic flue blocks for single wall chimneys Requirements and test methods o EN13069 2005 Chimneys clay ceramic outer walls for system chimneys Requirements and test methods o EN 13063 2006 system chimneys with clay ceramic flue liners Parte 1 Requirements and test methods for sootfire resistance e EN 12446 2003 Chimneys Components Concrete outer wall elements o EN 1443 2003 Chimneys General requirements e EN1856 1 2003 Chimneys Requirements for metal chimneys Part 1 System chimney products e EN1856 2 2004 Chimneys Requirements for metal chimneys Part 2 Flue liners and junctions 5 Fan kit diagram e The when installing the equipment must be incorporated in the fixed conduit means to disconnect the apparatus according to the legislation in force e If the supply cord is damaged it must be replaced by the manufacturer or his duly authorized agent because the power cord has special technical features Electric Scheme Operation of the Fan I Thermostat Low Speed O off II Manual High Speed Danger of Electrocution The tasks of handling and installation of the electrical components of the stove ADF must be carried out by professionally qualified person aware of the dangers and knowle
12. fabricante de equipamentos t rmicos Installation and User s Manual NM R Series 75 It is important to read this manual carefully before installing and using your appliance Vi 05 06 2014 2 adr Index 1 Introduction 3 2 Diagram of equipment 6 3 Technical Features 7 4 Installation 10 5 Fan kit Diagram 15 6 Using the equiment 16 7 Maintenance and Cleaning 17 8 Troubleshooting 20 9 Warranty Conditions 21 10 Warranty Certificate 22 ac 1 Introduction First of all we would like to congratulate you on purchasing your ADF appliance The result of a constant search for innovation and quality these appliances are designed and constructed in accordance with both current Portuguese and European legislation guaranteeing excellent heating performance in the homes where they are installed So that you can enjoy the full benefits of the appliance you have just purchased this manual will provide all the information you need for its correct installation and use Wood An ecological form of energy As a totally renewable resource wood is the most ecological and economical way of producing heat in your home The quantity of CO2 released during the combustion of wood is no higher than what would be released from its natural decomposition which has occurred over millions of years on the planet The carbon dioxide released in its burning and that which is absorbed during its useful life balances itself out which mea
13. ney Since both the height of the chimney and any breaks in pressure in the chimney are directly linked to its draft the conduits should have the straightest trajectory possible or where that is impossible the angle shouldn t exceed 45 Vertical indination is too oe _ sharp aon ae inclination INCORRECT CORRECT Ideally the flue conduit is constructed to pass up the inside of the building ensuring a better insulation and avoiding any unwanted condensation originating from differences in temperature that sooner or later could damage the system The tubing should be preferably in Stainless steel and thermally insulated along its whole length in order to avoid condensation specially in cold climates Chimneys should have a single flue and the grouping of several chimneys into a shared flue is not advised 11 0 adr The flue conduit for conveying the smoke must be unbroken from leaving the appliance to the evacuation of smoke into the atmosphere The form of the chimney cap must not obstruct currents of air from the outside In other words it must allow the air to enter through one side and leave through the opposite side so as not to cause descending currents of air The sizes recommended for flues for the appliance can be found on page 7 of this manual As you can see the correct installation of the chimney is a crucial aspect for obtaining the best possible performance from your appliance and given its technical n
14. ns it does not contribute to the green house warming effect of the planet Wood ash is a fertiliser that is rich in minerals and easily absorbed into the atmosphere in a totally ecological way Combustivel gt gt adr Wood Utilization Selection Not all wood has the same heating power In general opt for hardwoods such as oak beech or fruit trees the wood of which produces beautiful flames and embers that remain glowing for a long time Don t use logs that are too big Drying whatever wood you choose it must be completely dry damp or green wood doesn t heat as well since a large part of the energy is consumed in the evaporation of the water it contains Besides this damp wood produces a large amount of smoke and a poor flame which creates soot inside the stove on the glass and in the chimney Wood should be covered or sheltered from the rain but well ventilated Generally the wood should have a drying period of two years Avoid Using Resinous woods These woods release a lot of heat but burn quickly and produce embers and resin which dirty the chimney and the interior of the stove Never use Wood which has varnish paint cement and glues These can release toxic gases besides damaging the stove All ADF appliances are designed to burn wood and only wood that is dry with less than 20 humidity Damp wood or other types of fuel that are not recommended will lead to loss of guarantee a acr Hea
15. s 7 3 Close the door 4 Choose a position on the air combustion control to achieve a regular lasting burn avoid an excessive burn Note o You should only reload the stove when the previous load has been completely consumed Dont overload your stove e The paint coating the stove was not subjected to cooking in an oven so it will harden with the first time used Also why on first use emission of fumes and odors may occur Avoid inhalation and ventilate the surrounding space 15 a adF Using the Equipment 480 NM RS Ignition LIGHTING FROM COLD 1 When using this appliance for the first time or after a prolonged break it is extremely important to carefully examine the chimney and check that it is clean and unobstructed If you have any problems ask a professional to carry out an inspection 2 The appliance was designed to function intermittently with intervals for loading wood of between 45 to 60 min 3 Completely open the air combustion controls 1 and 2 air control Page 6 At the bottom of the stove place a product that burns easily firelighters pine needles pine cones or other 4 On the top of this place small logs stacked horizontally around 1Kg 5 Leave the door slightly open with a gap of 2cm This will allow air to get in and help the fire get started more quickly and efficiently Keep the air combustion control completely open 6 After 5 to 10 minutes close the door reduce the amount of air
16. t Propagation There are three forms of heat transmission in a Biomass appliance However it is through radiation that your appliance will gain the greatest benefits Your stove will naturally cause air movements which are sucked into the lower part and released through the upper part of the stove This phenomena is called natural convection You may also choose to install a fan in the base of the stove in order to obtain forced convection so as to increase the speed at which hot air is expelled and the distance that it reaches The fan is thermally controlled by a thermostat that is calibrated for 50 C So the venting begins when this temperature is reached and rests when temperature drops below this value a convection gt conduction do do A na hs VAN Nes radiation 2 Diagram of equipment NMR Series 820 NM RS 480 NM RS PE esse RE oe Air combustion control 820 NM R Released convection Air combustion control 1 480 NM RS Es Flue outlet Air combustion control 2 480 NM RS ER Ventilation Control Note the compartment beneath the combustion chamber should not be used as wood deposit adr 3 Thecnical Features Technical Features ES 820 NMR 480 NMR Nominal Heat Output 12 5 Energy Efficiency 73 OC 0 6 Average temperature of 450 combustion products P e 3 5 0 5 Chimney draft at nominal heat output Recommended maximum load Maximum humidity of wood Minimum distan
17. ted homes or those with forced air ventilation in the kitchen or bathroom it is advisable to place a ventilation grill on an outer wall near the appliance This safety mechanism is important to avoid oxygen in the room from running out and from avoiding smoke from the chimney The area of the fresh air grill should be at least 100 cm2 and should always be kept unblocked 7 Maintenance and Cleaning Your appliance can function for various years without any major maintenance operations However you can increase its operating life and considerably diminish the risks if you follow these principles of Cleaning and Maintenance Cleaning and maintenance operations should always be carried out when the appliance is cold Cleaning v empty the ash drawer often thus preventing contact with the ash grate your cause warping bearing in mind that these may remain hot enough until hours after flame extinction Y If sooting appears on the glass it can normally be removed by using a product specifically for cleaning glass If the darkening persists ask ADF or one of our agents for a cleaning product specifically to remove carbon residues 17 adr Maitenance V Fires When the cold season ends a time when your appliance can rest for some time carry out a comprehensive cleaning of ashes and any residue inside the stove without using any abrasive products With the help of an ash vacuum cleaner vacuum the burning chamber Clean
18. u engage your installation by a qualified and accredited professional Be careful the outside of the stove is hot Use suitable protective gloves whenever you need to touch any of the hot parts of the appliance or to load the wood while it is working Don t use your appliance as an incinerator Burning domestic waste could cause the release of toxic fumes and cause the early corrosion of the components of your appliance and the loss of guarantee The appliance is not a toy Keep children away from it Check that the flue system is properly sized ensuring a good run and that meets European standards so that no undue flue outlet to the surroundings occurs Keep any possible inflammable materials at a safe distance from the appliance minimum 1 5 metres NEVER use combustible liquids The first time you use your stove you may notice a slight odour from the curing of the paint Avoid inhaling it and ventilate the surrounding space well In the case of adverse weather conditions that disrupt the circulation of smoke is advisable not to utliza o equipment adr 4 Installation All local regulations including those that reference to national or European standards must be adhered to when installing the g apparatus s The Chimney You will only get the maximum efficiency from your appliance if the chimney is also efficient Before installing your ADF appliance check that the chimney is clean and unobstructe