Home
Data sheet DB EN IB IL 24 DI8/HD-PAC
Contents
1. 9 Connection notes and examples When connecting the sensors observe the as signment of the terminal points to the process data NOTE Malfunction The sensors and Us must be supplied from the same voltage supply Figure 5 Example of a connection of sensors when using external busbars The simplest way to meet this requirement is to use the IB IL PD 24V PAC terminal Wire the 24 V sensor connections to this terminal In this way they are supplied from the potential jumper Us of the Inline station 7984_en_01 PHOENIX CONTACT 7 IB IL 24 DI8 HD PAC 10 Application examples 11 Process data IB IL 24 DI 8 HD PAC Assignment of the terminal points to IN process data IBS IL 24 BK T U PAC IB IL PD 24V PAC Byte Bit Byte Byte 0 view Bt 7 6 5 4 3 2 j1 jo 1 1 Termi 2 4 1 4 2 3 1 3 2 2 1 2 2 1 nal point signal Status in LED 7 5 14 13 2 1 dicator For the assignment of the illustrated byte bit view to your INTERBUS control or computer system please refer to the DB GB IBS SYS ADDRESS data sheet Figure 6 Connection of sensors when using the IB IL PD 24V PAC terminal Figure 7 Connection of sensors when using external bus bars 7984 _en_01 PHOENIX CONTACT GmbH amp Co KG 32823 Blomberg Germany Phone 49 0 5235 3 00 8 PHOENIX CONTACT P O Box 4100 Harrisburg PA 17111 0100 USA e Phone 717 944 1300 www phoenixcontact com
2. kPa 106 kPa up to 3000 m above sea level 70 kPa 106 kPa up to 3000 m above sea level IP20 Ill IEC 61140 EN 61140 VDE 0140 1 Inline connectors Spring cage connection 0 08 mm 1 5mm 28 16 Inline data jumper 500 kbps 24 V DC nominal value max 5 5 mA DC 7 5VDC max 30 mA DC max 0 25 W at UL max 0 72 W 8 Spring cage connection 1 wire EN 61131 2 types 1 and 3 24V DC Typ 2 4 mA 3V DC 5V DC 11 V DC 30 V DC 1 ms 1 ms 30 m BE 190 81 129 8 bits 1 byte 0 byte 0 byte 8 bits A For the programming data configuration data of other bus systems please refer to the corresponding electronic device data sheet e g GSD EDS 7984_en_01 PHOENIX CONTACT 4 IB IL 24 DI8 HD PAC PROFIBUS telegram data Required parameter data 3 Byte Need for configuration data 4 Byte Electrical isolation isolation of the voltage areas 5 V supply incoming remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 5 V supply outgoing remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 7 5 V supply bus logics 24 V supply I O 500 V AC 50 Hz 1 min 24 V supply I O functional earth ground 500 V AC 50 Hz 1 min of the power supply units in the 24 V area is not permitted see also user manual A To achieve electrical isolation between the logic level and the I O area supply these areas from separate power supply units Interconnection Approvals For the lates
3. IB IL 24 DI8 HD PAC Inline digital input terminal 8 inputs 24 V DC AUTOMATION Data sheet 7984 _en_O1 PHOENIX CONTACT 2011 01 06 1 Description The terminal block has been developed for use in an Inline station It is used to acquire digital signals Features Connections for eight digital sensors Connection of sensors in 1 wire technology Diagnostic and status indicators This data sheet is only valid in association with the IL SYS INST UM E user manual Make sure you always use the latest documentation It can be downloaded from the product at www phoenixcontact net catalog e me D OGD OO GD GD 0 GD OO OD contac GD INSPIRING INNOVATIONS IB IL 24 DI8 HD PAC 2 Table of contents 1 DES CUDUO garments meee oy area Pama ream ie cent tweet tm OOO ee EY Bee aE mR npr ce 1 2 Table OF COMP INS reren R E EEE 2 3 qe 21d i ale da aa a a Re Ke Ee ene mete ee 3 4 Be STed alg fers Keo tc Caameeers meen cenea Steeneter o ert gira ote SO ae eee ere ee ee eee nen eee ee ee 3 5 AddiionaltaDle Ssnan aa aa eee ee eee 5 6 MernareCUtdiagr aN aaen a E A E A 6 7 Local status ANd diagnostic indicators ccecccsececeeeeceeeeneeeeeeeeneeesseeeseueeseeeeseeesseeesseeeaeeeseeenes 6 8 Terminal point ASSIGNMENT cccccecsssceseceeseeeeseesecenseeceueeseueeeseeteaeeseeessseesseeenseessaeetentensenees 7 9 Connection notes and examples ccccecccssccceeccceeeceuecceeceuceceuceceeecsu
4. dimensions Housing dimensions General data Color Green Weight 60g With connector Operating mode Process data mode with one byte Ambient temperature operation 25 GC 55 C Ambient temperature storage transport 25 C 85 C Permissible humidity operation 10 95 according to DIN EN 61131 2 Permissible humidity storage transport 10 95 according to DIN EN 61131 2 7984_en_01 PHOENIX CONTACT 3 General data Air pressure operation Air pressure storage transport Degree of protection Protection class Connection data Name Type of connection Conductor cross section solid stranded Conductor cross section AWG Interface Inline local bus Type of connection Transmission speed Power consumption Segment supply voltage Us Current consumption from Us Communications power UL Current consumption from UL Power consumption Power loss Digital inputs Number of inputs Type of connection Connection method Description of the input Nominal input voltage Nominal input current Input voltage range 0 signal Input voltage range 1 signal Delay at signal change from 0 to 1 Delay at signal change from 1 to O Permissible conductor length to the sensor Programming Data ID code hex ID code dec Length code hex Length code dec Process data channel Input address area Output address area Parameter channel PCP Register length bus IB IL 24 DI8 HD PAC 70
5. eeceueesaeeesueesueeseeesaueesaaes 7 10 Application example Seaan as eile cee eet ee aaa eee es eee aiatioes 8 11 PrOCOSS 6 5 2 Rea ee UR ea a oe a eee ee ee 8 7984 en_01 PHOENIX CONTACT 2 IB IL 24 DI8 HD PAC 3 Ordering data Description Type Order No Pcs PKt Inline digital input terminal complete with accessories connector and la IB IL 24 DI8 HD PAC 2700173 1 beling field 8 inputs 24 V DC single wire connection method Accessories Type Order No Pcs Pkt Connector for digital 1 2 or 8 channel Inline terminals Plug Adapter IB IL SCN 8 2726337 10 Labeling field width 12 2 mm Marking IB IL FIELD 2 2727501 10 Inline terminal for power distribution 24 V complete with accessories IB IL PD 24V PAC 2862987 1 connector and labeling field 24 V supply voltage is fed out from the seg ment circuit US Inline terminal for power distribution GND complete with accessories IB IL PD GND PAC 2862990 1 connector and labeling field connections for GND VARIOFACE front adapter for 8 channel Inline HD modules Plug Adapter FLKM 14 PA INLINE DIO8 2900889 1 Documentation Type Order No Pcs Pkt User manual English Automation terminals of the Inline product range ILSYS INST UME Data sheet English DB GB IBS SYS ADDRESS INTERBUS addressing 4 Technical data Dimensions nominal sizes in mm 140 5 119 8 Width 12 2 mm Height 119 8 mm Depth 71 5mm Note on
6. t approvals please visit www phoenixcontact net catalog 5 Additional tables Input characteristic curve Input voltage U V Typical input current I mA 30 lt U lt 0 7 0 3 0 12 6 1 32 9 2 32 12 2 36 15 2 36 18 2 36 21 2 36 24 2 40 27 2 40 30 2 40 7984 en_01 PHOENIX CONTACT 5 6 Internal circuit diagram Local bus 24V U 24V U Figure 1 Internal wiring of the terminal points Protocol chip Bus logic including voltage conditioning LED status indicator Optocoupler Digital input Explanation for other used symbols has been provided in the IL SYS INST UM E user manu ae al 7984 en_01 IB IL 24 DI8 HD PAC 7 Local status and diagnostic indicators Figure 2 Local status and diagnostic indicators Designa Color tion D Green Diagnostics bus and logic voltage Status of the inputs Function identification Light blue PHOENIX CONTACT 6 IB IL 24 DI8 HD PAC 8 Terminal point assignment IB IL PD 24V PAC IB IL 24 DI8 HD PAC IB IL PD GND PAC an Figure 3 Terminal point assignment Figure 4 Typical connection of sensors when terminals Terminal point Assignment for potential distribution are used Eee oe a The sensors can also be connected via external busbars En 1 2 2 2 signal input IN 3 IN 4 sure that the sensors and Ug are supplied from the same 1 3 2 3 Signal input IN5 IN6 voltage supply 1 4 2 4 Signal input IN 7 IN 8