Home

read me first !! platform software for dt- 6x60

image

Contents

1. READ ME FIRST PLATFORM SOFTWARE FOR DT 6X60 EMBEDDED NETWORK PROCESSORS RELEASE NOTES BUILDS 1 0 1 1 2 0 AND 2 1 RELEASE VERSION 2 1 379 Campus Drive Suite 100 N Somerset NJ 08873 fax 732 667 1091 phone 732 667 1080 email sales datatekcorp com Dateic http www datatekcorp com APPLICATIONS INC DT 6X60 Platform Release Notes Release 2 1 TABLE OF CONTENTS 2 Product Features 3 Release Changes 3 1 New for Build 2 1 u u J 9 3 1 1 New and Changed Commands 3 1 2 Other Changes 3 2 New for 2 9 3 2 1 New and Changed Commands 3 2 2 Command Output Changes 3 223 Other Changes 3 3 New ol a o Da a a u au u 10 3 3 1 New and Changed Commands 3 3 2 Command Output Changes 3 3 3 Other Changes 3 4 New for Build 1 0 11 3 4 1 New and Changed Commands 3 4 2 Command Output Changes 3 4 3 Other Changes 4 Installation Addendum 4 1 Obtaining Information from Datatek 4 2 Procedures For Upgrading to Build 2 x of the Platform Software 4 2 1 Conversion of DT 6X60 Platform Software to Build 2 1 From Build 2 0 or 1 X 14 4 2 2 Conversion of DT 6X60 Platform Software to Build 2 1 From Build 2 0 or 1 X For a
2. command called local offers a more convenient way to configure or reconfigure the platform IP parameters Syntax local simplex ipaddr lt IP address gt submask lt Subnet mask gt gateway lt Gateway IP address gt duplex ippublic lt shared IP address gt ipother lt IP address of other DT 6X60 gt Parameters not given on the command line are prompted Using the local command is more convenient than individually using the ipaddr submask gateway ippublic and ipother commands The simplex option may be used when converting the unit from redundant to simplex It causes the values of the ippublic and ipother parameters to be changed to none The duplex option may be used when converting the unit from simplex to redundant It causes the administrator to be prompted for the ippublic and ipother values OTHER CHANGES This release supports the two new features of the DT6backup DT6retrieve and DT6upgrade utilities which are the ability to bypass using FTP and the ability to do upgrades initiated by the support server This release supports future apps that use a very large number of TCP connections Flow control of the serial port console does not block use of the telnet console Excessively long flow control on the serial port will drop serial port output 3 2 NEWFOR BUILD 2 0 3 2 1 NEW AND CHANGED COMMANDS new command called console configures the list of closed user groups CUGs that defines which IP addres
3. 24 9459 25 9460 26 9527 27 9528 28 9625 29 9626 30 25 9627 lt tuna DT 6160 gt If the DT 6X60 platform software is not registered vfy app will show the application status as rfs ready for service The hardware information needed for the key generation process which is the MAC address and hardware serial number of the DT 6X60 can be obtained by running either the rstpass command or vfy mod command The same MAC address and serial number are also used in generating an application key Supply Datatek with this information and the software version two part build number of the platform to which you are upgrading and the software version s two part build number s of the application s that are resident or to be installed on the platform 4 3 1 SPECIAL CONSIDERATIONS FOR DUPLEX OPERATION Note that in a duplex operation the platform and applications must be registered on the standby also The keys are different because the standby has a different MAC address and hardware serial number than the active So obtain the MAC address and hardware serial number on the standby for key generation by Datatek Switchover will not work properly if the software on the standby is not registered 1 Note that the rstpass command supplies one other piece of information called access that is used only to generate a one time key for resetting a forgotten password to the
4. Articles 110 16 110 17 and 110 18 of the National Electrical Code ANSI NFPA No 70 Other Installations Exempt from the Enforcement of the National Electrical Code May Be Engineered According to the Accepted Practices of the Local Telecommunications Utility Fora unit used with an AC Wall Plug In Unit read and understand the following e The unit was tested with the Phi Hong Model PSA 30U 240 Wall Plug In Unit 110 240V AC 24V DC Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning Do not staple or otherwise attach the power supply cord to the building surfaces Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock The socket outlet shall be installed near the equipment and shall be readily accessible The Wall Plug In unit may be equipped with a three wire grounding type plug a plug having a third grounding pin This plug is intended to fit only into a grounding type power outlet Do not defeat the safety purpose of the grounding type plug Do not allow anything to rest on the power cord Do not locate this product where persons walking on it may abuse the cord Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled into the produc
5. above MULTIMATE 1 1 and above TN3270 13 0 and above X25PAD 23 1 and above ONSITE Not Available Yet 3 Registration Similar to the DT 6061 platform software the DT 6X60 platform software must be registered for each DT 6X60 on which it is installed In addition each application must be registered for each DT 6X60 on which it is installed An application is registered only once per DT 6X60 regardless of the number of instances of that application running on a particular DT 6X60 Note that the application s will not run after the new platform software is installed unless both the platform application s are registered Keys may be obtained in advance of the installation of software Changing either the release level or the version level requires that a new key be obtained and the re registration of the particular software entity See section 4 3 for details It is imperative that the installation addendum section be reviewed and followed in order to minimize any impact on your installations 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 4 Changing the Platform IP address Use the new local command beginning with build 2 1 to change all the IP parameters simultaneously Without the local command if you need to change the IP address ipaddr to another IP network the gateway or the submask values must be changed in a specific order as
6. before active and standby can communicate with one another To date these switches include certain models of Cisco Ethernet switches The customer must set up the configuration and test it before beginning live production as the delay required varies depending on the model of switch used It is impossible for Datatek or Tollgrade to try all models that a customer may chose to use Switchover problems have not been experienced to date when Ethernet switches from other manufacturers are used or when plain hubs are used 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Anew command called phy has been implemented Syntax phy auto 10hdx 100hdx The default is auto The last two options force the physical layer to 10 or 100 half duplex while auto allows auto configuration The phy configuration is independent for the two machines in a redundant configuration This command is used in conjunction with the delay parameter above when necessary but the recommendation is to not set the value for phy which means it will default to auto COMMAND OUTPUT CHANGES Vfy stby was changed to show the delay value Vfy mod was changed to show the value of the phy OTHER CHANGES None 3 4 New For BUILD 1 0 3 4 1 NEW AND CHANGED COMMANDS Q Two new options have been added to the stby command dlog and reset Syntax stby dlog Syntax stby reset Two new logs are available on the active system
7. downloading accessing or otherwise using the SOFTWARE you agree to be bound by the terms of this LICENSE If you do not agree to the terms of this LICENSE Manufacturer is unwilling to license the SOFTWARE to you In such event you may not use or copy the SOFTWARE and you should promptly contact Manufacturer for instructions on return of the unused product s for a refund 7 1 SOFTWARE LICENSE You may only install and use one copy of the SOFTWARE on the HARDWARE unless otherwise licensed by Manufacturer The SOFTWARE may not be installed accessed displayed run shared or used concurrently on or from different computers including a workstation terminal or other digital electronic device Devices Notwithstanding the foregoing and except as otherwise provided below any number of Devices may access or otherwise utilize the services of the SOFTWARE You may not reverse engineer decompile or disassemble the SOFTWARE except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation The SOFTWARE is licensed as a single product Its component parts may not be separated for use on more than one HARDWARE The SOFTWARE is licensed with the HARDWARE as a single integrated product The SOFTWARE may only be used with the HARDWARE as set forth in this LICENSE You may not rent lease or lend the SOFTWARE in any manner You may permanently transfer all of your rights under this LICENSE only a
8. follows 1 Delete the gateway value by entering gateway none 2 Change the IP address using the ipaddr command 3 Change the value of the submask to reflect the new network 4 Enter a new gateway address using the gateway command All three values must belong to the same subnetwork 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 1 INTRODUCTION These release notes highlight the product features modifications known caveats and any special considerations for the DT 6X60 products For detailed information on these products reference the DT 6X60 User s Manual 2 PRODUCT FEATURES The DT 6X60 Embedded Network Processor is a network applications computer that applies customer specific protocol operations protocol translation and termination of network connections that require such a function in a distributed network The DT 6X60 supports a multitude of applications and can support combinations of most applications simultaneously The elements common to all applications are provided by the DT 6X60 hardware and operating environment In addition the DT 6X60 has an SNMP agent that is completely independent of any application A pair of DT 6X60 s can be configured for active standby operation where the standby DT 6X60 automatically takes over as active and continues operations seamlessly if the active DT 6X60 fails The table below provides the comparison between the three memb
9. platform software using the register command see section 4 3 below for details on the registration process The application key s remain s the same there is no need to re enter the key s for the application s Using the console for the active DT 6X60 switchover from active to standby using the switchover command 10 Verify the previous standby machine is now the active machine and verify all the applications are operating as they did on the old active machine 11 Repeat steps 5 through 8 above for the new standby machine After both units have been upgraded if sean and age were previously set using the active console reset their values to their previous ones Note that the active machine will propagate these settings to the standby so there is no need to reconfigure the standby 4 3 REGISTRATION The DT 6X60 platform software requires a key for activation In addition any application running on platform software build 1 0 and above requires a key for activation After installing new platform software and rebooting before the DT 6X60 may return to service the software must be registered that is the key installed for this version of software The application s resident on this DT 6X60 platform build must be registered also Once the reboot is executed the application s will not run until the application registration process is completed One key is needed for the DT 6X60 platform and one key for each different application
10. resident on this DT 6X60 regardless of the number of instances of that application on this particular DT 6X60 Use the register command to register the DT 6X60 platform module and regapp command to register a resident application Changing either the release level or the version level requires that a new key be obtained and the re registration of the particular software entity If the key has been previously installed for an application and only new platform installed then only the platform software has to be re registered Similarly if only new application software is installed then only the application software must be re registered To obtain a key for new platform software run the register command which will produce the output similar to that shown below Contact Datatek with the information in order to obtain the software key Rerun the register command and enter the software key at the prompt or on the command line lt tuna DT 6160 gt register Product_Code DT 6160 MAC 0 96 29 2 55 219 HW_SERNUM 0 0 6 240 61 162 Build_Number 1 0 Build_Date Wed Apr 7 17 19 07 EST 2004 Enter key J No key entered lt tuna DT 6160 gt The vfy mod command displays the state of the registration 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 lt tuna DT 6160 gt vfy mod Module is DT 6160 Registered hostname tuna ippublic 192 168 8 250 status Active ipother 192 168 8 13 label tu
11. which pertain to the standby system alarm log showing the major alarms on the standby system A standby activity log The first log is viewed by entering any of the commands vfy stby stby or stby vfy The second log is viewed by entering the command stby dlog Both logs are cleaned out and restarted by entering the command stby reset All of the above commands are executed on the active system Two new options have been added to the ping command Syntax ping c lt count gt Syntax ping c The c lt count gt option specifies the number of times the ping command is executed It overrides the default of 3 The c option with no number means that the ping command executes indefinitely until the console user enters a del delete character in order to kill it COMMAND OUTPUT CHANGES The vfy app command when run on the serial console of the DT 6X60 now outputs the build number and date for each application properly installed The DT 6X60 can be either the active or standby machine in a duplex configuration Depending on the application involved it also may show the state or status of an application for that particular instance The output of the command has been corrected in this release to show the correct status when the module is not registered The vfy mod command now shows the product type DT 6160 or DT 6260 along with the registration status P 02 04 10 Datatek Applications Inc DT 6X60 Platform Release
12. 30 simultaneous instances and the DT 6260 48 instances of any application including X25PAD Note that a DT 6X60 still only supports one instance of MULTIMATE IP LTCN or IP VCON application and that is the only application that can be installed in the DT 6X60 at a time due to the way these applications function The functionality and command structure of the DT 6X60 products are similar to that of the DT 6061 DT 6X60 platform software started with build 16 1 of the DT 6061 as its base and it is upon that build the enhanced software capabilities of the DT 6X60 products have their origin along with of course the new faster and higher capacity hardware 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 3 RELEASE CHANGES The functionality and command structure of the DT 6X60 products are similar to that of the DT 6061 It is suggested that one review the functionality and command changes in the release notes for the platform software for the DT 6061 builds 14 15 16 and 16 1 if you have current DT 6061 s running on platform build 13 1 or earlier and are unfamiliar with the changes DT 6X60 platform software started with build 16 1 of the DT 6061 as its base and it is upon that build the enhanced software capabilities of the DT 6X60 products have their origin along with of course the new faster and higher capacity hardware 3 1 NEW FOR BUILD 2 1 3 1 1 NEW AND CHANGED COMMANDS
13. DATATEK Load modules for all the Datatek migration products are available only by sending email to either Bill Arndt at arndt datatekcorp com or Dan Conklin at conklin datatekcorp com All other documentation including release notes user manuals white papers etc can be accessed on the Datatek web site and downloaded for your use To insure that the correct version of the binary load module file have been retrieved and has not been corrupted during the transmission process the UNIX sum command can be used After unzipping if necessary and transmitting the file to the target UNIX host server from the PC to which the load module was initially sent from Datatek on the UNIX host Key in sum lt name of downloaded file gt The values returned must match the numbers shown below Key in sum basekupd dt6 Response 48914 866 basekupd dt6 Key in sum base1upd dt6 Response 5146 1794 base1upd dt6 Key in sum base2upd dt6 Response 26679 1860 base2upd dt6 For new hardware purchases the platform software and application load modules and keys see below were already preinstalled at the factory The customer only has to configure the module and applications per local needs UNIX is a registered trademark in the United States and other countries licensed exclusively through X Open Company Ltd 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 4 2 PROCEDURES FOR UPGRADI
14. DC or AC voltage sources See User s Manual before connecting to the power source The 48 V DC input terminals are only provided for installations in Restricted Access Areas locations Do not use this product near water for example in a wet basement Never touch non insulated wiring or terminals carrying direct current or leave this wiring exposed Protect and tape wiring and terminals to avoid risk of fire electric shock and injury to service personnel To reduce the risk of electrical shock do not disassemble this product Only trained personnel should perform servicing Opening or removing covers and or circuit boards may expose you to dangerous voltages or other risks Incorrect re assembly can cause electric shock when the unit is subsequently used For a unit intended to be powered from 48 V DC voltage sources read and understand the following e This equipment must be provided with a readily accessible disconnect device as part of the building installation Ensure that there is no exposed wire when the input power cables are connected to the unit Installation must include an independent frame ground drop to building ground Refer to User s Manual OOO OO OOOO D S This symbol is marked on the DT 6X60 adjacent to the ground earth area for the connection of the ground earth conductor e This Equipment is to be Installed Only in Restricted Access Areas on Business and Customer Premises Applications in Accordance with
15. MPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT WITH REGARD TO THE SOFTWARE AND THE ACCOMPANYING WRITTEN MATERIALS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHERS WHICH VARY FROM STATE JURISDICTION TO STATE JURISDICTION 7 7 SPECIAL PROVISIONS The SOFTWARE and documentation are provided with RESTRICTED RIGHTS Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and HARDWARE Software clause at DFARS 252 227 7013 or subparagraphs c 1 and 2 of the Commercial HARDWARE Software Restricted 3 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Rights at 48 CFR 52 227 19 as applicable Manufacturer is Datatek Applications Inc 379 Campus Drive Suite 100 Somerset NJ 08873 If you acquired the SOFTWARE in the United States of America this Software License are governed by the laws of the State of New Jersey excluding its choice of laws provisions If you acquired the SOFTWARE outside the United States of America local law may apply This LICENSE constitutes the entire understanding and agreement between you and the Manufacturer in relation to the SOFTWARE and supercedes any and all prior or other communications statements documents agreements or other information between the parties with respect to the subject matter he
16. NG TO BUILD 2 X OF THE PLATFORM SOFTWARE 4 2 1 CONVERSION OF DT 6X60 PLATFORM SOFTWARE TO BUILD 2 1 FROM BUILD 2 0 OR 1 X 1 Obtain the platform update software for build 2 x from Datatek and transmit it to your UNIX FTP host after unzipping The platform should already be running application s that are compatible with the DT 6X60 platform builds so there is no need to obtain new copies of the application s See the DT 6X60 User s Manual for the syntax of all commands From the DT 6X60 serial port console 2 Backup the configurations on your DT 6X60 to your host using the back command for safety Install the software module basekupd only using the install command and reboot Install the two software modules base1upd and 2 in that order using the install command Reboot Obtain a new key from Datatek and re register the platform software using the register command see section 4 3 below for details on the registration process The application key s remain s the same However there is no need to re enter the for the application s 7 Verify each application is operating the same as it was before the conversion Note that for the IP LTCN application additional conversion steps are required with respect to DT 4000 s and DT 4180 s See the IP LTCN Build 13 or higher Release Notes for additional detail 4 2 2 CONVERSION OF DT 6X60 PLATFORM SOFTWARE TO BUILD 2 1 FROM BUILD 2 0 OR 1 X FOR A REDUNDAN
17. Notes Release 2 1 OTHER CHANGES The standby reports major alarms when either the module and or the applications are not registered An alarm log is available on the active system for major alarms generated on the standby The log is viewed via the vfy stby command The SNMP object ID for the product code is the following for each of the DT 6XXX products 1 DT 6061 1 3 6 1 4 1 3791 3 7 2 DT 6160 1 3 6 1 4 1 3791 3 13 3 DT 6260 1 3 6 1 4 1 3791 3 14 The DT 6X60 will reject an attempt to install the DT 6061 platform software In a duplex configuration a DT 6X60 will reject any attempt to use a DT 6061 as the other partner The product types must be the same in a duplex configuration In a duplex configuration if an inconsistency is detected between the active and standby for example the active is a DT 6061 and the standby is a DT 6160 the standby will wait four and a half minutes disable the standby console and reboot 30 seconds later After rebooting if the inconsistency is still detected it repeats the cycle This prevents the active and standby from synchronizing thus disabling the ability to switchover from one to the other The four and one half minute interval allows the console operator time to investigate what the problem is and take corrective action 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 4 INSTALLATION ADDENDUM 4 1 OBTAINING INFORMATION FROM
18. ORT SOFTWARE support is not provided by Manufacturer or its affiliates or subsidiaries separate from the HARDWARE For SOFTWARE support please contact your supplier of the HARDWARE SOFTWARE support is limited to the warranty period stated below unless either a separate contract has been consummated between you and the manufacturer or the manufacturer has agreed in writing at the time of purchase by you of the software to an extension of the warranty Should you have any questions concerning this LICENSE or if you desire to contact Manufacturer for any other reason please refer to the address provided in the documentation for the HARDWARE 7 4 EXPORT RESTRICTIONS You agree that you will not export or re export the SOFTWARE to any country person or entity subject to U S export restrictions You specifically agree not to export or re export the SOFTWARE i to any country to which the U S has embargoed or restricted the export of goods or services which as of March 1998 include but are not necessarily limited to Cuba Iran Iraq Libya North Korea Sudan and Syria or to any national of any such country wherever located who intends to transmit or transport the products back to such country ii to any person or entity who you know or have reason to know will utilize the SOFTWARE or portion thereof in the design development or production of nuclear chemical or biological weapons or iii to any person or entity who has been prohibited fro
19. Redundant Duplex SYSTEM 4 3 Registration 4 3 1 Special Considerations for Duplex Operation 4 4 Constraint 5 Documentation http www datatekcorp com index php support release notes 6 Hardware Warranty 7 End User License Agreement for Software Software License Intellectual Property Rights Software Support Export Restrictions Limited Warranty No Other Warranties Special Provisions 8 Limitation of Liability 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Important Safety Instructions The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product When installing operating or maintaining this equipment basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following Read and understand all instructions Follow all warnings and instructions marked on this product For information on proper mounting instructions consult the User s Manual provided with this product The telecommunications interface should not leave the building premises unless connected to telecommunication devices providing primary and secondary protection This product should only be operated from the type of power source indicated in the User s Manual This unit must be powered from either 48 V
20. T DUPLEX SYSTEM 1 Obtain the platform update software from Datatek and transmit it to your UNIX FTP host after unzipping The platform should already be running application s that are compatible with build 2 platform builds so there is no need to obtain new copies of the application s See the DT 6X60 User s Manual for the syntax of all commands Using the console for the active DT 6X60 set scan 999 and age 2 using the stby cfg command If scan and age have not been previously set skip this step Using the console for the active DT 6X60 backup the configurations to your host for the applications on this DT 6X60 using the back command If the standby configuration is not up to date with the active use the console for the standby DT 6X60 to either retrieve the configuration from the backup obtained in the previous step or update the configuration directly from the active by executing the command stbyupd cfg Using the console for the standby DT 6X60 install the software module basekupd only using the install command and reboot Install the two software modules base1upd 2 in that order using the install command Reboot the standby At this point if automatic scanning was enabled previously it is now suppressed because the active is running older software 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Obtain a new key from Datatek and re register the standby
21. default value 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 4 4 CONSTRAINT The value for submask ipaddr and gateway must all belong to the same subnetwork If the subnetwork must be changed set the gateway value to none first then set ipaddr the submask and gateway to their new values in that order Then reboot 5 DOCUMENTATION The current version of the DT 6X60 user manual is Release Version 2 1 It is available for download from the Datatek web site www datatekcorp com at URL http www datatekcorp com index php support release notes 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 6 HARDWARE WARRANTY The warranty period for hardware shall be ninety 90 days from the date of shipment from Datatek Applications Inc Replacements and repairs are guaranteed for the longer of the remaining original warranty period or 30 days 7 END USER LICENSE AGREEMENT FOR SOFTWARE This License Agreement License is a legal contract between you and the manufacturer Manufacturer of the system HARDWARE with which you acquired software product s identified above SOFTWARE The SOFTWARE may include printed materials that accompany the SOFTWARE Any software provided along with the SOFTWARE that is associated with a separate end user license agreement is licensed to you under the terms of that license agreement By installing copying
22. ers of the DT 6xxx family DT 6061 DT 6160 DT 6260 Feature 1 5 RTU s LAN Interface T 10M 10 100M 10 100M Number of Instances Application s SNMP Agent 48V 36 72 DC Input Telnet Console for Apps Secure Shell SSH2 Closed User Groups See App See App See App Alarm Grid Connector Temperature Alarms Embedded DT 9001 to OnSite OnSite OnSite SNMP Trap App App App Applications are IP BHI 2 IP SLM X25PAD TN3270 B2APRT IP SPOOL IP LTCN IPVCON IP FANOUT ONSITE MULTIMATE others 3 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 A DT 6160 and DT 6260 differ only by the number of instances each supports 30 for the DT 6160 and 48 for the DT 6260 Note that either type of DT 6X60 can be powered over an ethernet cable with no other power input connections This is a new capability with the DT 6X60 products which is not available in the DT 6061 Also because the resources required by the X25PAD application has grown with the addition of several new features in the last few releases the DT 6061 may not support all 30 instances due to the resources required as the result of several new features in the last few X25PAD builds and how the application is configured for your installation However the system resources available on the DT 6X60 series are much larger and faster than those on the DT 6061 so a DT 6160 can support
23. lease The second field is the maintenance level of the software the version Various commands require both fields so when supplying build information to Datatek for key generation etc supply the complete two part build number Generally text showing only the first part means that whatever is being discussed applies to any and all versions of that release base 2 Platform and Application Compatibility Build 1 0 represents the first release of the platform software for the DT 6X60 that runs applications compatible with the older DT 6061 Embedded Network Processors All new releases of applications for the DT 6061 series starting January 1 2004 and built to run on platform build 16 0 or higher will run on DT 6X60 platform build 1 0 and later but not on build 15 or earlier of the DT 6061 Application software that currently runs on DT 6061 build 15 will continue to work on DT 6061 build 16 X but will not work on the new DT 6X60 hardware or on future platform releases for the DT 6061 See the table on the next page showing the compatibility of application software releases with current and future platform software releases 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Application Build Compatibility Table B2APRT 9 0 and above 6 1 and above IP E2A 4 1 and above IP FANOUT Not Available Yet IP LTCN 14 0 and above IP SLM 9 1 and above IP SPOOL 12 0 and above IP VCON 10 0 and
24. m participating in U S export transactions by any federal agency of the U S government 7 5 LIMITED WARRANTY Manufacturer warrants that a the SOFTWARE will perform substantially in accordance with the accompanying written materials for a period of ninety 90 days from the date of shipment from Datatek Applications Inc Software support is limited to the hours of 9 AM to 5 PM ET Monday through Friday excluding Datatek observed holidays Other coverage and extended warranty may be purchased at additional cost Any implied warranties on the SOFTWARE are limited to ninety 90 days Some states jurisdictions do not allow limitations on duration of an implied warranty so the above limitation may not apply to you Manufacturer s and its suppliers entire liability and your exclusive remedy shall be at Manufacturer s option either a return of the price paid or b repair or replacement of the SOFTWARE that does not meet this Limited Warranty and which is returned to Manufacturer with a copy of your receipt This Limited Warranty is void if failure of the SOFTWARE has resulted from accident abuse or misapplication Any replacement SOFTWARE will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer 7 6 No OTHER WARRANTIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW MANUFACTURER AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO I
25. na ipaddr 192 168 8 20 submask 255 255 255 0 gateway 192 168 8 1 mac addr 0 96 29 2 55 219 serial 0 0 6 239 61 162 build 1 0 rtu 5 built on Wed Apr 7 17 19 07 EST 2004 booted 3 08 days ago lt tuna DT 6160 gt Similarly to obtain a key for registering the application s run the regapp command tuna DT 6160 gt regapp 4J Unregistered applications ip_bhi Build 6 0 Fri Oct 25 08 44 47 EDT 2002 MAC Address 0 96 29 2 55 219 Serial Number 0 0 6 240 61 162 application registration key KEY J Usage regapp lt key gt lt tuna DT 6160 gt A typical output of the vfy app is displayed below lt tuna DT 6160 gt vfy J Installed applications b2aprt Build 7 0 Wed Oct 23 14 22 11 EDT 2002 ip_bhi Build 6 0 Fri Oct 25 08 44 47 EDT 2002 Not Registered ipspool Build 11 0 Mon Oct 6 14 27 15 EDT 2003 tn3270 Build 12 0 Fri Oct 18 13 32 56 EDT 2002 x25pad Build 22 0 Thu Jan 15 11 19 30 EST 2004 Running applications 1 b2aprt 9190 2 none 9193 none 9197 none 9202 none 9210 P 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 none 9223 none 9236 none 9237 none 9238 10 x25pad 9461 11 x25pad 9523 12 x25pad 9524 13 x25pad 9525 14 x25pad 9526 15 x25pad 9343 16 x25pad 9344 17 x25pad 9345 18 x25pad 9346 19 x25pad 9347 20 none 12054 _bhi unreg 21 9456 22 9457 23 9458
26. reof 8 LIMITATION OF LIABILITY To the maximum extent permitted by applicable law in no event shall Manufacturer or its suppliers be liable for any damages whatsoever including without limitation special incidental consequential or indirect damages for personal injury loss of business profits business interruption loss of business information or any other pecuniary loss arising out of the use of or inability to use this product even if Manufacturer has been advised of the possibility of such damages In any case Manufacturer s and its suppliers entire liability under any provision of this License shall be limited to the amount actually paid by you for the SOFTWARE and or the HARDWARE Because some states jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the above limitation may not apply to you Copyright 2003 2010 Datatek Applications Inc All Rights Reserved Printed in USA 02 04 10 Datatek Applications Inc
27. s part of a permanent sale or transfer of the HARDWARE provided you retain no copies you transfer all of the SOFTWARE including all component parts the media and printed materials any upgrades this LICENSE and if applicable the Certificate s of Authenticity and the recipient agrees to the terms of this LICENSE If the SOFTWARE is an upgrade any transfer must also include all prior versions of the SOFTWARE Without prejudice to any other rights Manufacturer may terminate this LICENSE if you fail to comply with the terms and conditions of this LICENSE In such event you must destroy all copies of the SOFTWARE and all of its component parts 7 2 INTELLECTUAL PROPERTY RIGHTS The SOFTWARE is licensed not sold to you The SOFTWARE is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties You may not copy the printed materials accompanying the SOFTWARE All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE is the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties This LICENSE grants you no rights to use such content All rights not expressly granted under this LICENSE are reserved Manufacturer and its licensors if any 3 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 7 3 SOFTWARE SUPP
28. sed similarity in the command set across the DT product line COMMAND OUTPUT CHANGES The CUG command error handling and error messages were improved Small changes were made in message punctuation A problem was fixed concerning deleted CUGs OTHER CHANGES The platform administrator can now telnet to 1023 the DT 6XXX platform for access to the serial console functions Some assignments such as the IP address gateway address and submask must still be performed via the console connected to the serial port but the rest of the platform commands can then be executed via the new telnet platform console or the current platform serial console The two sources of console input are merged and treated as a single console input and all console output is directed to both telnet and the serial port except for post shutdown and early booting messages which appear only on the serial port 3 3 NEW FOR BUILD 1 1 3 3 1 NEW AND CHANGED COMMANDS Q Anew parameter has been added to the stby cfg command Syntax stby cfg delay lt 0 20 gt In a duplex DT 6X60 configuration this parameter adds extra delay in the detection and switchover processes of approximately 6 seconds for each increment of delay The default is delay 0 Delay none or delay 0 uses the same parameters as previous implementations Setting this parameter is only recommended for network connections where an Ethernet switch between the active and standby introduces a long delay
29. ses are allowed to connect to the new platform telnet console See Other Changes section below The closed user groups must first be configured using the CUG command then they may be added to the console CUG list Syntax console cug lt cuglist gt cug none A new command vfy console was added to show the list of CUGs assigned to the new telnet platform console 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 Q Anew argument has been added to the diag command per user request Syntax diag killcon lt instance gt platform The diag killcon command provides a means to free up the telnet port of an instance or the platform in case someone left it connected and someone else needs to use it The telnet connection is broken without terminating the instance or rebooting the platform Since TCP does not provide an approved means for a third party to break the connection this command should not be routinely used It does not for example shut down or notify the far end telnet client Only when the client tries to send new input will it find out the connection is broken Datatek recommends use of the timeout configuration for the platform console and most application consoles Timeout configures a maximum idle time at which the console will automatically be logged out The command named reload has been added which is a synonym for the present retrieve command This command was introduced for increa
30. t c If the product has been exposed to rain or water d If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions because improper adjustment of other controls may result in damage and will often require extensive work by qualified technician to restore the product to normal operation If the product has been dropped or the cabinet has been damaged If the product exhibits a distinct change in performance Save These Instructions 02 04 10 Datatek Applications Inc DT 6X60 Platform Release Notes Release 2 1 IMPORTANT USER DOCUMENTATION IS AVAILABLE AT OUR WEB SITE Documentation http Awww datatekcorp com Sales sales datatekcorp com Two products are covered in these release notes DT 6160 and DT 6260 Generically these will be referred to as DT 6X60 in the descriptions below Only when necessary will an actual product name be used These products have many similarities with DT 6061 but have different power options and capabilities When systems are duplexed the same product must be used for both the active and standby processors SPECIAL INSTALLATION AND UPGRADE PROCEDURES New Build Numbers Build numbers beginning with the first release consist of two parts a release number and version level Technically this software is called software version 2 1 The first field is the base re