Home

Quick Start Guide IncuCountV3

image

Contents

1. effects Once set click on Profile or Image to close manual control box Always save profile parameters immediately after exiting the settings box 5 Determine if you will use a calibration image to subtract background for mare accurate counting Note that this may not always work as small defects in an agar plate can create problems after subtraction For best results always use a pristine plate or filter devoid of marks and bubbles To Save a calibration plate profile simply use the same camera settings already loaded into the camera parameters press Save and name the calibration file Then select Apply Calibration Image For the remainder of the steps involved in setting the count parameters REMEMBER TO ALWAYS ENSURE THAT Image AND Preview ARE SELECTED ON THE TOP MENU BAR 6 We suggest unselecting the Light Colonies button when measuring mast types of colonies Sometimes plaques and dark opaque agar give better counts when using light colony mode 7 Press the Count button to get an idea how things look at this point Colonies outlined in green will be counted Those outlined in red fall outside the counting parameters and will not be counted The red and green outlines change dynamically as you adjust the parameters You can stretch and pinch to zoom and expand to see the details Set the Counting Region by selecting this option under Manual tab on the menu bar Touch the Center button to see
2. re New Hampshire Avenue sute 125 Portsmouth NH 03801 Quick Start Guide IncuCount IncuCount Automated Colony Counter HARDWARE INSTALLATION Before setting up any new counting parameter please ensure the system is properly set up as described in the user manual SOFTWARE SET U Optimize and set up Colony Profile for each plate type to be counted 1 Select and then turn on overhead or backlit lighting The knobs are in the back of the system and have four different settings note which one you use for each Parameter Profile setting Backlit lighting is most commonly used because of the higher contrast it produces Overhead lighting is best for counting in color and or when using opaque matrices 2 Turn on Nexus tablet by holding the power button for 3 seconds The IncuCount application will automatically load 3 Place sample into the IncuCount system and then view image by selecting Image and Preview from the top menu bar The camera will autofocus and this focus can be adjusted later 4 Set camera controls Under Camera Controls in the menu bar select Manual First adjust focus if needed Next adjust Exposure Brightness and Contrast All four of these settings can be roughly set by pointing to the setting bar and dragging the bar to the desired setting area Fine tuning can be made by using the and buttons at the top of each bar Note that adjusting power line frequency can help modulate for LED flicker
3. the counting region highlighted in green Use the button to reduce the diameter by a few millimeters to help avoid spurious signals which are common to the edge of the plate www bulldog bie com tel re New Hampshire Avenue sute 125 Portsmouth NH038901 8 Set colony count parameters First select the Profile button or touch image to get back to main screen Press the small button next to the Min Size value Set the Min Size threshold smallest colony size to ignore small dust particles etc we suggest going one to three clicks smaller than your current plate to accommodate for plate to plate variation Next set the Max Size threshold in a similar manner by allowing a little extra size for variation The last setting is L to W Ratio which looks at the length to width comparison for each object and rejects it if the ratio is beyond a certain level This is a good way to get rid of irregularly shaped images that are not likely to be colonies As before give it a little leeway in case of plate to plate variation Save in Profile see the end of step 4 9 If you plan to count by color press the Color Chooser button A bar of 10 color squares will appear Touch the color that appear most appropriate Note that the colors don t always match perfectly so perform a COUNT to help optimize the best color bins to use for your counting application Save in Profile 10 Adjusting the Threshold count level is the la
4. st parameter needed for optimization This unlabeled slide bar is to the immediate right of the image while in the Profile screen By clicking and dragging the button get an idea where the counts are most accurate Then use the small buttons at the top and bottom of the slider to fine tune your counting Save this parameter setting This is now your final Colony Parameter file Save in Profile COUNTING Count Using Saved Colony Profiles 11 First check to make sure your colony profile is loaded 12 Press the Count button 13 After counting files can be saved under the File tab on the menu bar as a jpg by pressing Save Data If you d prefer to have a printed document then select Save POF Either of these can be viewed later by simply selecting Load Profile www bulldog bie com tel 570 4248 fax 66 0524

Download Pdf Manuals

image

Related Search

Related Contents

Philips docking system for iPod/iPhone/iPad DCB291  510-SMAN-E-4454-V1.5, Layout 1  Targus Twill 13.3"  TRUST WIRELESS ALARM SYSTEM 200N  Apprendre à pêcher pour la première fois au salon de l`agriculture !  A-9050 Amplificador estéreo integrado    USO DE ADOBE CONNECT Requisitos de uso Reserva de salas  BL67 - USER MANUAL FOR CANOPEN  Instruction Booklet  

Copyright © All rights reserved.
Failed to retrieve file