Home

Preface 1 Change Log 2 List of Abbreviations 3

image

Contents

1. BUGFIX Changing of the Time Domain of a Storage Profile could modify other Settings In case the Time Domain of a Storage Profile was changed other settings like the Threshold Type or the Timer Interval Format within the Stop Trigger table could be modified unintentionally BUGFIX Wrong Detection of not existing Stop Events In case of a stop event like Value is 0 the stop trigger could fire even in case the value was never 0 after the start event This wrong behavior was caused by an internal status variable which was not reset at the moment of the start event BUGFIX Possible Memory Leak within the simulated Devices The clean up of send buffers for simulated devices could be missing in case of low memory conditions English Release 2014 11 54 81 CMS X Tools Change Log CMS 26 X Tools V 03 05 gt X Tools V 04 00 IR1 The following changes have been introduced in X Tools V 04 00 IR1 FEATURE Additional Analyzing Function GetStartTime The new Analyzing Function GetStartTime can be used in order to determine the start time of an offline data FEATURE Additional Analyzing Function GetStopTime The new Analyzing Function GetStopTime can be used in order to determine the stop time of an offline data FEATURE Additional Analyzing Function Sleep The new Analyzing Function Sleep can be used in order to pause the processing of the parent Analyzing Script for the specified am
2. BUGFIX Disabling of the User Account Anonymous It was not possible to disable the user account Anonymous BUGFIX Not ending editing within Trees even after the Tree has been resized In case editing of a tree item had been started and the width of the tree was changed afterwards the editing did not stop automatically and caused wrong graphical effects BUGFIX Corrected writing of offline Data through the STS The STS did not access its to be written offline data properly while it was writing it As a result another system like the ANS or the MTS could also access the currently written offline data in parallel to the STS in which case the read information may have been invalid English Release 2014 11 21 81 CMS X Tools Change Log CMS BUGFIX Improved zooming for very small Time Intervals within the MTC yt T001 The minimal period of time which can be displayed by the MTC yt T001 is 25 ns In case the zooming rectangle was used and its defined time interval was less than 25 ns the MTC yt T001 zoomed in y direction only Now the time interval at the t axis is being set to 25 ns in case the zooming rectangle defined a time interval of less than 25 ns BUGFIX Missing Check of the available Memory before the Start of Analyzing Models Scripts Before the start of Analyzing Models and Analyzing Scripts the available physical memory was not checked As a result it was possible that the X Tools Server consumed too much w
3. BUGFIX Possible Crash because of improper Access to Data The synchronization of the access to the reference counters of data was not strong enough and could lead to situations where a data was freed by X Tools although it was still in use As a result log entries like The han dle to signal xyz was closed too many times and also crashes of the X Tools Server could appear BUGFIX Possible Crash because of improper Access to Data within the Monitoring System A certain timing could clear the copies of data within the Monitoring Engine while they were accessed by other threads and as a result the X Tools Server could crash BUGFIX Possible appearing of unwanted Values in Action based Operating Modes The action based operating modes of Analyzing Models and Analyzing Scripts have considered not only the present data values but also the stored event information like source present start stop data available start stop In some cases additional values were added at the moments of an event The rules for the gen erating of events have been changed so that the relevant events like source present start or data available start do not appear earlier than the first probe any more BUGFIX Possible Crash because of a too early Return of LoadData A certain timing could cause the Analyzing Function LoadData to detect a finished loading although the actual loading was still in progress As a result LoadData c
4. FEATURE Source Machine Information for all System Log Entries The information about the source machine is now being added to each system log entry In case of environ ments with multiple X Tools Servers and or in cases where the X Tools Client and the X Tools Server are run ning at different machines the information about the source machine identifies the source of each system log entry FEATURE Additional Minimum Time Format for Analyzing Models and Analyzing Scripts The Offline Time Configuration table of Analyzing Model Editors and Analyzing Script Editors now provides the additional minimum time format Use Start Time of the Analyzing Model Analyzing Script In case this time for mat is being chosen the first calculated timestamp matches the start time of the Analyzing Model Analyzing Script exactly English Release 2014 11 5 81 CMS X Tools Change Log CMS FEATURE Reset Functionality for IEEE1394 Devices All IEEE1394 devices can be reset by X Tools now Under certain circumstances it was possible before that an IEEE1394 device stopped to respond In order to enable this reset functionality the according device must be of product version A2 or later FEATURE Improved loading of very big Offline Data Files In previous versions it was not possible to load offline data files which were bigger than the available amount of RAM even in case a data reduction was configured for the loading Now X Tools can load also very b
5. The Loading Mode Changes and Interval did not work properly under certain conditions BUGFIX Storage Profiles and Storage Mode Changes and Interval The Storage Mode Changes and Interval did not work properly under certain conditions BUGFIX Advanced Export using Export Mode Changes and Interval The Export Mode Changes and Interval did not work properly under certain conditions BUGFIX Operation of hidden Menu Bar in Editors Clicking onto menu bars which were set to hidden did not result in the according operation in some cases BUGFIX Invalid Check of the Header Mask Within Device Profiles of ION ARCNET Spy T001 ION PROFIBUS DP Spy T001 and ION PROFIBUS DP T001 devices the check of the header mask could fail in rare cases because a wrong internal offset was being used BUGFIX Possible Hang during the Startup of Configuration Files In very rare cases there was a possibility for a hung during the startup of a Configuration File BUGFIX Disabled Previous and Next Buttons within the System Log Viewer Under certain conditions the Previous and Next buttons of the System Log Viewer have not been enabled as it should be BUGFIX Default Values for Bit Arrays in Device Profiles The names for the default values of bit arrays within Device Profiles were generated with an index starting from O instead of starting from 1 BUGFIX lt F2 gt stops to work with
6. as a result the parent Analyzing Program suspended when it detected such a data at its input BUGFIX Possibly missing Vales at the End of each stored offline Data File The last values before the end of the stored offline data file could be missing The biggest effects of this behav ior could be seen within offline data files which should contain a post trigger time because there were no values stored during the post trigger time in some cases BUGFIX Possible Crash in case of Analyzing Models or Analyzing Scripts which contain more than one Instance of the Analyzing Function MonLog An internal race condition could cause a crash in case the Analyzing Function MonLog was used more than once within an Analyzing Model or Analyzing Script BUGFIX Too early return of the Analyzing Function Start In case the Analyzing Function Start was configured to wait until its to be started Configuration File has en tered the status stopped again it sometimes could return also after a suspend and resume of its to be started Configuration File In this case the to be started Configuration File still could be in status suspended or started at the moment after Start has returned BUGFIX Unwanted suspend of sequential Analyzing Scripts which call Analyzing Functions like Start In case an Analyzing Function like Start has returned an error code e g because its to be started Configura tion File could not be started the parent Anal
7. printMVF The printMVF command line argument can be used in order to print a Monitoring View FEATURE Passing of Command Line Arguments via a Web Browser The X Tools Client registers for the URI scheme xtools As a result the command line arguments of the X Tools Client also can be called via links out of web browsers FEATURE Additional Log Entries about erroneous third Party Analyzing Functions In case an error is detected within the interface of a third party Analyzing Function an according log entry is created FEATURE New Setup All variants of X Tools are delivered with a new setup FEATURE Advanced Cursors and Frequency Markers within automatic Reports In case the advanced cursors and or the frequency markers of a MTC yn T001 are turned on at the moment when the Monitoring View is saved they are added also to the image of each automatic report which is created through the Monitoring View afterwards FEATURE Improved Labels for Advanced Cursors and Frequency Markers within the MTC yn T001 Via the context menu of each advanced cursor frequency marker within the MTC yn T001 it is possible now to choose whether the label and or the value shall be displayed at the bottom and or at the top of the vertical line FEATURE Each Subharmonic and Harmonic can be moved The MTC yn T001 allows to move each of the displayed subharmonics and harmonics FEATURE Improved loading of Offline Data In case the loading
8. button has been pressed BUGFIX Possible Flood of Log Entries in case of low Disk Space In case there was no more space available at the disk to which the log entries should be stored there was a possibility to end up in a large amount of log entries about log entries which could not be written BUGFIX Possible Crash of the Storage System in case its Input Data disappears and reappears There was a possibility to end up with a crash of the Storage System in case the input data of the Storage Pro file disappeared and reappeared English Release 2014 11 33 81 CMS X Tools Change Log CMS BUGFIX Possible Crash of the Storage System in Combination with very long File Paths There was a possibility to end up with a crash of the Storage System in case the path to the to be stored offline data files was very long longer than 512 bytes BUGFIX Possible Flood of Log Entries when using the simulated ION BinaryInput T001 In case the simulated ION Binarylnput T001 was configured with a sample time of bigger than 250 ms a lot of log entries about a too slow simulation could occur BUGFIX Possible Corruption of the Time Correction In case of bad timing the occurrence of a single timestamp error could cause a corruption of the time correction which lead to several log entries before the time correction could recover again BUGFIX The ANF Start handles stopping Configuration Files wrongly In case the ANF Start is being used in or
9. table within the MVE Standard T001 can be used in order to define and run simple calcula tions The MTS Explorer displays the available libraries of Analyzing Functions and User Functions now in the same way like the ANS Explorer and allows to drag Functions directly into the Formula Editor table FEATURE Additional Analyzing Function ShellExecute The new Analyzing Function ShilExe can be used in order to call a Windows shell command FEATURE Additional Analyzing Function WaitForFileSplitting The new Analyzing Function WaitForFS can be used in order to wait until the specified Storage Profile has completed another file splitting Afterwards further processing like loading of the latest offline data files can be performed FEATURE Additional Analyzing Function ExportData The new Analyzing Function ExpriData can be used in order to export an offline data from the MDS Explorer to a csv file FEATURE Additional Analyzing Function InputConstant The new Analyzing Function InConst can be used in order to pass constant values to Analyzing Models The output of this Analyzing Function can be linked also to input arguments of type parameter like the number of points of the Analyzing Function Buffer which is not possible with the output of other Analyzing Functions FEATURE Additional Monitoring Chart MTC ynt T001 The new Monitoring Chart can be used in order to visualize 1 dimensional buffers e g a spec
10. BUGFIX Constant connect and disconnect of CTN WatchGuard T001 Devices In case of CTN WatchGuard T001 devices without any started Device Profiles these devices have been contin uously connected and disconnected because the life check did not work properly BUGFIX Attach detach of CTN WatchGuard T001 Devices did not produce Entries to the System Log Whenever a CTN WatchGuard T001 was connected to or disconnected from the X Tools Server the according message has not been added to the System Log BUGFIX Disappearing CTN WatchGuard T001 in Combination with Operating Mode Watchdog Devices of type CTN WatchGuard T001 disappeared after a short time of operation in case the chosen operat ing mode was Watchdog BUGFIX Missing Probes within the Data Streaming of CTN WatchGuard T001 Devices There were values missing in the data streaming from CTN WatchGuard T001 devices BUGFIX Missing attach detach Messages for the CTN WatchGuard T001 There were no attach detach messages for CTN WatchGuard T001 devices in some cases when the device disappeared reappeared BUGFIX Calculations with twice the same Signal with Analyzing Scripts The same signal could not be used for multiple arguments of a single Analyzing Function BUGFIX Device Profiles and Record Mode Interval only The Record Mode Interval only did not work properly under certain conditions BUGFIX Loading Profiles and Loading Mode Changes and Interval
11. Even after the Set as Standard button within the Chart Styles dialog of a Monitoring Chart had been pressed the currently configured chart background was not applied to the new Monitoring Charts of the same type which were created afterwards BUGFIX Wrong Indication of connected Links within the Analyzing Function Properties Dialogs In case of Analyzing Functions with a variable number of input arguments the Analyzing Function Properties dialogs of the AME Standard T001 and UFE Standard T001 could display the Link connected information for wrong input arguments BUGFIX Possible Communication Errors with ION SIMATIC TDC T001 Devices The communication between the X Tools Server and ION SIMATIC TDC T001 devices could run into an error and could cause connection breaks in case of certain packet lengths English Release 2014 11 66 81 CMS X Tools Change Log CMS 2 9 X Tools V 04 00 gt X Tools V 04 01 The following changes have been introduced in X Tools V 04 01 Feature Additional Analyzing Function ReadStringFromFile The new Analyzing Function ReadStringFromFile can be used in order to read a string from a ini file Feature Additional Analyzing Function ReadValueFromFile The new Analyzing Function ReadValueFromFile can be used in order to read a value Boolean Integer or Decimal from a ini file Feature Additional Analyzing Function WriteStringToFile The new Analyzing Function WriteStringT
12. are forwarded to the new Configuration File as default values of its provided parameters FEATURE Support of Frequency Markers also for Order Spectrums Frequency markers can be turned on also within a MTC yn T001 which contains an order spectrum FEATURE Opening of Monitoring Views in full Screen Mode In case the openMVF command line argument in order to open a Monitoring View the additional fullscreen command line argument can be passed in order to open the specified Monitoring View in full screen mode FEATURE Additional Item Configuration File Control for the MTC Mimic Board T001 The additional item type Configuration File Control can be used within the MTC Mimic Board T001 in order to show the current status of a Configuration File and in order to start or stop the Configuration File FEATURE Update Mechanism for the Installation of Hotfixes Future hotfixes come with an Update exe executable which automatically determines the current installation folder and which copies all of the binaries which are relevant for one or multiple hotfixes English Release 2014 11 69 81 CMS X Tools Change Log CMS FEATURE Manual Trigger for Monitoring Views Monitoring Views now can be configured so that they create a report at the moment when they are started After the report has been created the Monitoring View stops automatically FEATURE Parameters for Device Profiles All Device Profile Editors now allow to configure
13. for Storage Profiles In addition to the common states of all Configuration Files e g stopped started suspended paused Stor age Profiles now also point out via their icon when they are in status Triggering FEATURE 3D Visualization of 2 dimensional Buffers The new MTC ynm T001 can be used in order to visualize the data of 2 dimensional buffers in the 3 dimensional space The visualization can be moved and rotated freely and provides different ways of interpola tion like bars color gradients and surface FEATURE Firmware Update for Interface Nodes The firmware of Interface Nodes can be updated via X Tools and IEEE1394 FEATURE Sequence Control for Measurement and Analysis Tasks The powerful mechanism of sequential Analyzing Scripts allows to start and stop other Configuration Files In terface Profiles Device Profiles Analyzing Models Analyzing Scripts and Storage Profiles automatically It can be used in order to automate massive any measurement and analysis tasks FEATURE Start of a Monitoring View via the Command Line Storage Profiles now also can be configured to store offline data to the disk FEATURE Storage Profiles for offline Data Storage Profiles now also can be configured to store offline data to the disk Therefore also the SPE Binary T001 accepts dropping of offline data now FEATURE Smart Updating of the Information within Trees The X Tools Client now does not read information about Conf
14. BUGFIX Unwanted moving of Categories within the MDS Explorer In case a category should be copied from the Online Data branch of the MDX Explorer to the Offline Data branch of the MDS Explorer or vice versa a move operation was performed instead BUGFIX Possible Crash of the X Tools Server In case a Storage Profile was configured to a Storage Mode of Interval only the X Tools Server could crash in case the Storage Profile suspended at some moment and was stopped afterwards BUGFIX Not working automatic Update of User Functions In case the input interface of a User Function was created for an input argument of an Analyzing Function which was after a configurable input argument of this Analyzing Function the automatic update of the User Function failed during the opening within the UFE Standard T001 English Release 2014 11 52 81 CMS X Tools Change Log CMS BUGFIX Missing Alignment of Measurement Cursors within the MTC yt T001 In cases with multiple MTC yt T001 within one Monitoring View the cursor lines could be shifted a little bit away from each other after zooming operations BUGFIX Wrong Number of Values within the Info for Offline Data Files In some cases the information about offline data files which is visible within the ODL Standard T001 showed a number of values which was 1 or 2 too high BUGFIX Wrong last Probe within Offline Data Files In case there was a value with a timestamp at the mome
15. Dialogs In order to make the context menu of the Storage Parameters and Export Parameters available the value had to be edited at least once In addition there was an unneeded separator at the end of the context menu of these two cells BUGFIX Bad Handling of invalid Inputs within the Manual scale y Axis Dialog There was no warning and no other indication in case the entered minimal value was smaller than the entered maximal value No both values are written with red text and an according message is being displayed in case Apply or OK are being pressed In case of the Manual scale t Axis dialog there was an according message but the minimum time value and maximum time value texts did not turn to red BUGFIX No Connection to the X Tools Server in case of too low Values for the Connection Retries In case the Connection Retries within the Global Options Editor were set to 1 the X Tools Client was unable to connect to the X Tools Server at all BUGFIX Storing of Main Profiles with an invalid Pair of Passwords In case two different passwords were specified for a user within a Main Profile it still was possible to store the Main Profile after the according error message has been acknowledged English Release 2014 11 22 81 CMS X Tools Change Log CMS BUGFIX Storing of the User Accounts with an invalid Pair of Passwords In case two different passwords were specified for a user with
16. In case the Monitoring Charts within a MVE Standard T001 were scrolled to the left right top bottom some axis labels were not moved together with their Monitoring Chart and controls like the sliders were not operable any more BUGFIX Possible Crash in case of automatic Reports with the MTC ynm T001 In case the MTC ynm T001 was used within a Monitoring View and this Monitoring View had to create an auto matic report the X Tools Server could crash BUGFIX Possible Hang of the X Tools Server A certain timing could lead to a hang of the X Tools Server while it tried to terminate itself BUGFIX Possibly wrong Unit at the x Axis of a MTC yn T001 In case the MTC yn T001 displayed a spectrum and the values at the x axis were in MHz the axis unit was displayed as kHz BUGFIX Visualization Artifacts in case of a hidden Title Bar of a Monitoring Chart In case the title bar of a Monitoring Chart was hidden the buttons of the title bar still could be displayed behind the slider BUGFIX Possible Crash after opening of a Monitoring View which contains empty Monitoring Charts In case a Monitoring View was opened which contained an empty MTC Orbit T001 MTC Vector2D T001 MTC ynm T001 or MTC ynt T001 the X Tools Client could crash BUGFIX Wrong Names of Data Types The Analyzing Function Overview User Function Overview Analyzing Function Properties and User Function Properties dialogs have shown wrong names for inputs outputs of type
17. Moving to V 5 1 SP1 Update3 of the Automation License Manager The installer of X Tools now installs V 5 1 SP1 Update3 of the Automation License Manager CHANGE Improved CRC Checks for all Configuration Files The CRC of all Configuration Files is checked now before the file becomes available to X Tools CHANGE Changed minimal Ring Buffer Size within the Global Options of the X Tools Server The minimal value for the Default Ring Buffer Size within the global options of the X Tools Server has been changed from 1000 to 10 CHANGE Notification about unavailable Input Analyzing Functions In case a data is dragged from the MDS Explorer and dropped into the AME Standard T001 or UFE Standard T001 the status bar of the X Tools Client now provides a short information in case there is no input Analyzing Function available which could be inserted for the dropped data English Release 2014 11 46 81 CMS X Tools Change Log CMS CHANGE Review of the Log Entries from the X Tools Service All log entries of the X Tools Service have been reviewed in order to achieve a more common look and feel and improved quality of the provided information CHANGE Modified Detection of Configuration File States through Start and WaitForCF In case the Analyzing Functions Start and WaitForCF wait for the stop of a Configuration File a resume at tempt which can cause a stop and a start of the target Configuration File is not treated
18. Takeover of the Time Base during the Conversion of a Monitoring Chart In case a Monitoring Chart of one type e g MTC yt T001 or MTC yn T001 is converted into another type e g MTC yx T001 or MTC ynt T001 the time base from the source Monitoring Chart is taken over automatically as time base of the destination Monitoring Chart FEATURE Warning about skipped State Changes from the Analyzing Function MonCF In case the Analyzing Function MonCF is called too slowly it may not be able to report each of the requested state changes When this situation is detected an according warning is added to the system log FEATURE Improved Undo and Redo within the Analyzing System The AME Standard T001 ASE Standard T001 and UFE Standard T001 now allow to undo and to redo each operation which is performed within any of their editable cells CHANGE Increased maximal Number of Parameters which can be passed to StartEx The number of parameters which can be passed to the Analyzing Function StartEx has been increased from 64 to 128 parameters CHANGE Additional moving of Frequency Markers The harmonics of frequency markers and all value based frequency markers can be moved now like it already was possible to move the Main Frequency Marker CHANGE Output Data of simulated IFN VIB ACC Devices Each channel of a simulated IFN VIB ACC now outputs a kind of noisy sine CHANGE Reusing of an already existing ODL Standard T001 In case the Loa
19. thus the device cali bration which is performed during the production was not in effect BUGFIX Inconsistent File modified Flag within Monitoring Views Zooming shifting and scaling operations sometimes caused the file modified flag to be set and sometimes not Now any kind of zooming shifting and scaling does not set this flag BUGFIX Possibly missing Output of Values through User Functions There was a possibility to end up with an output interface for a User Function which did not receive any value during the execution of the User Function It was needed to delete and re create such output interfaces in previ ous versions of X Tools Now the situation should not occur any more and already stored wrong User Func tions from previous versions of X Tools are corrected automatically during the execution BUGFIX Possible Race Condition within the Analyzing Function InOrdRsmpl When the Analyzing Function InOrdRsmpl was used for online data calculations it may have been unable to determine the start place of the revolution BUGFIX Wrong automatic scaling within the MTC Orbit T001 and MTC Vector2D T001 The automatic scaling of the axes of the MTC Orbit T001 and of the MTC Vector2D T001 was sometimes too slow to update to the correct values In addition the origin could get lost to a position different to 0 0 in case the aspect ratio was unlocked and both axes were configured to auto scale independently BUGFIX Wrong
20. Bad Navigation through the Provided Parameters Table of the AME Standard T001 In editing mode the Provided Parameters table of the AME Standard T001 did not support the cursor keys for the navigation through its cells BUGFIX An Analyzing Model Analyzing Script which processes Offline and Scalar Data may never stop In case an Analyzing Model or Analyzing Script was configured to use both Offline Data and Scalar Data as input and in case the calculation mode was configured to action based the Analyzing Model or Analyzing Script may never have reached the status stopped Instead it remained in status started and it did nothing after it completed to process the available data probes BUGFIX Possible Crash within the Analyzing Function GetVFrmSD The Analyzing Function GetVFrmSD could end up in a crash in case it attempted to read from a data too early while the data was created or too late while the data was terminated BUGFIX Possible Visualization of Values which do not match the currently shown Point in Time In case two offline data from different time intervals were dropped into a Monitoring Chart the Monitoring Chart could show values from both offline data for one point in time BUGFIX Possible Change of the currently shown Point in Time of a paused Monitoring Chart In case the visualization of a Monitoring Chart was paused and another online data was dropped into the Moni toring Chart afterwards the shown po
21. Events in loaded Offline Data There was a possibility that the same event was added multiple times to an offline data during its loading from the disk BUGFIX Too many Messages in case too many Windows shall be opened The maximal number of dialogs within a workspace is 31 In case e g 50 Analyzing Models were dragged into the empty Analyzing Workspace at once there were 50 31 19 message boxes that no more windows could be opened BUGFIX Wrong initial File Location for new Analyzing Models Analyzing Scripts In case a new Analyzing Model Analyzing Script was created via the according context menu item from an Ana lyzing Model Files or Analyzing Script Files branch the initial File Location of the new Analyzing Mod el Analyzing Script was not being set to the File Location from which the context menu has been called instead the default File Location was used as initial File Location BUGFIX Editing of Bit Arrays within Device Profile Editors The operations copy cut and remove did not work properly for bit arrays within the Device Profile Data table of Device Profile Editors BUGFIX Enabling of empty Rows within the Loading Profile Editor Within the Loading Profile Editor it was possible to check the Enabled entry for empty rows BUGFIX Suspending of Storage Profiles in case the specified Trigger Data is not available Storage Profiles did not suspend in case they were triggered by data and the specified da
22. FEATURE Additional Analyzing Function IIRBandStopFilterChebyshev2 The additional Analyzing Function IIRBandStopFilterChebyshev2 calculates an up to 10 th order IIR Cheby shev2 filter FEATURE Additional Analyzing Function lIRHighPassFilterChebyshev2 The additional Analyzing Function IIRHighPassFilterChebyshev2 calculates an up to 20 th order IIR Cheby shev2 filter FEATURE Additional Analyzing Function IIRLowPassFilterChebyshev2 The additional Analyzing Function IIRLowPassFilterChebyshev2 calculates an up to 20 th order IIR Cheby shev2 filter FEATURE Additional Analyzing Function Impulser The additional Analyzing Function Impulser generates an impulse signal with a chosen shape FEATURE Additional Analyzing Function Random The additional Analyzing Function Random generates a random signal within defined range FEATURE Additional Analyzing Function InputBuffer2D The additional Analyzing Function InputBuffer2D reads 2 dimensional online or offline buffer data from the system FEATURE Additional Analyzing Function InputOrderResampling The additional Analyzing Function InputOrderResampling re samples simple online or offline data from the system to use it for order analysis e g order FFT FEATURE Additional Analyzing Function OutputBuffer2D The additional Analyzing Function OutputBuffer2D writes 2 dimensional online or offline buffer data to the system FEATURE Additional Analyzing Func
23. Monitoring System e CMS X Tools User Manual 06 Analyzing System o provides detailed information about the functionality which is provided by the Analyzing System e CMS X Tools User Manual 07 Storage System o provides detailed information about the functionality which is provided by the Storage System e CMS X Tools Release Notes o provides additional information about the released version of CMS X Tools 1 2 Validity of this Document This document is valid for the following software e CMS X Tools Pro V 04 02 e CMS X Tools ODV V 04 02 During the following pages these software packages will be referred to by the term X Tools The change log bases on the most powerful edition Professional less powerful editions may not contain all of the listed fea tures 1 3 Audience This document is intended for personnel involved in the commissioning and using of the software e X Tools English Release 2014 11 4 81 CMS X Tools Change Log CMS 2 Change Log 2 1 X Tools V 03 00 gt X Tools V 03 01 The following changes have been introduced in X Tools V 03 01 FEATURE Data Name Prefix for Analyzing Models The Analyzing Model Editor now supports data name prefixes for input and output data Similar to the data name prefixes within Device Profiles the data name prefixes within Analyzing Models can be used in order to increase the reusability of Analyzing Models in case of environments with multiple similar tasks e g
24. Mux now starts with 0 instead of 1 CHANGE Consideration of the internal processing Delay for slow Channels of the IFN VIB A For sample rates of 4 kHz and above an internal filter stage is being used by the IFN VIB A For the slower sample rate of 333 Hz an additional filter stage is added and a third filter stage is used for a sample rate of 14 Hz Each additional filter stage causes a certain processing delay which now is being deducted by the X Tools Server CHANGE Improved Data Supervision The internal mechanism of the data supervision for Device Profiles has been improved in order to achieve less dependencies to other tasks of the X Tools Server CHANGE Faster Reaction to attaching of IEEE1394 Devices The reaction of the X Tools Server to attaching of IEEE1394 devices has been improved so that these devices appear within X Tools faster now CHANGE Improved Device Communication The communication to all devices from all types of interfaces was serialized through a common entry point This serialization has been removed which allows calls to multiple devices simultaneously CHANGE Improved Startup of Device Profiles The data manager is not being locked during the whole startup phase of Device Profiles any more As a result all other modules still can access the already present data also while a Device Profile is being started which causes less moments where the X Tools Client seems to be not reacting CHANGE Faster Outputs f
25. Orbit or 2 dimensional Vec tor BUGFIX Wrong storing of the State of Items within the MDS Explorer The full path to each expanded collapsed item inside the MDS Explorer was stored together with the item count of each branch As the item count is changing whenever items are added or removed a lot of redundant infor mation could be stored within the Global Settings gsf xtc file This amount of redundant information could cause very big files a very high memory usage through the X Tools Client a not responsive X Tools Client and wrong remembering of the state of tree items BUGFIX Broken Communication to OPC UA Servers In case the X Tools Server was configured as OPC UA client it was unable to read the address space from any OPC UA server BUGFIX Possible Crash because of a corrupted Monitoring View A corrupted Monitoring View could cause a crash of the X Tools Server and or of the X Tools Client BUGFIX Wrong Log Entry about a changed String Size through OutStr The Analyzing Function OutStr could output a log entry about a changed string size also in situations where the string size did not change English Release 2014 11 64 81 CMS X Tools Change Log CMS BUGFIX Failed automatic Update of an Analyzing Model Analyzing Models which contained InConst could fail to be updated automatically BUGFIX Starting of a Formula via the Formula Editor may not work In case the X Tools Client was connected to mo
26. RAM in case of low Memory Conditions As a result a once suspended Stor age Profile was not able to resume any more BUGFIX Too high CPU usage of suspended Analyzing Models Scripts In several cases it was possible that a suspended Analyzing Model or Analyzing Script needed more CPU per formance than a running Analyzing Model Analyzing Script BUGFIX Possibility of invalid output Data Names within Analyzing Models Scripts Within Analyzing Models and Analyzing Scripts it was possible to specify invalid names for output data Now Analyzing Models and Analyzing Scripts do not accept data names any more which would not be valid file names BUGFIX Not stored Cycle Time Unit Within the AME Standard T001 and within the ASE Standard T001 the configured unit of the cycle time was not stored and restored to default with each opening of the editor BUGFIX High CPU Usage during the Opening of certain Analyzing Models In cases of Analyzing Models which contain the same output data names for different output functions the sys tem could end up in frequent suspend and resume operations which caused a lot of entries to the system log and an increased CPU usage BUGFIX Trees do not remember the User configured Settings Within the AME Standard T001 the ASE Standard T001 and the MVE Standard T001 the user configured set tings of tables were not remembered even in case the global option Remember Settings of Tables was config ured to Yes
27. Shutdown of the X Tools Server In case the Storage System is configured in a way where more data shall be stored than the available disk throughput allows it can happen that the internal file buffers of the X Tools Server rise up to several MBytes When the X Tools Server is being shut down in such a moment it outputs a log message now which shows the current size of the file buffer FEATURE Support for exporting of Orbit Data to csv Files The new orbit data now also can be exported to csv files via the MDS Explorer and via the ODL Standard T001 FEATURE Support for exporting and Importing of Device Profiles for IFN Al and IFN VIB A The Device Profile Editors for the IFN Al and IFN VIB A now allow to export and import the data definitions via the context menu of the Device Profile Settings table CHANGE X Tools Tray Application The tray icon of the X Tools Server now is provided via a separate application CHANGE The Analyzing Function Delay supports only equidistant Operating Modes From now on Delay can be used only within Analyzing Models and Analyzing Scripts which are configured for an equidistant operating mode CHANGE Case insensitive Input of the Analyzing Function WaitForConfigurationFile The provided state information can be of any uppercase or lowercase now In addition the returned status now has an initial uppercase letter and following lowercase letters CHANGE Speedup of the loading of Offline Data Fil
28. T001 which now is able to load also the data from the SIPLUS CMS2000 system FEATURE Loading of Data from wav Files The ODL Binary T001 has been replaced by the ODL Standard T001 which now is able to load also the data from WAVE wav files English Release 2014 11 36 81 CMS X Tools Change Log CMS FEATURE Loading of Data from csv Files The ODL Binary T001 has been replaced by the ODL Standard T001 which now is able to load also the data from CSV csv files FEATURE Number of Data within the MDS Explorer Each branch within the MDS Explorer now displays how many data are present below it and all of its sub branches FEATURE Additional Information about each X Tools Server within the MMS Explorer The sub items of each X Tools Server within the MMS Explorer now provide additional information about its current connection state and authorization state FEATURE Information about the currently connected Clients within the MMS Explorer The sub items of each X Tools Server within the MMS Explorer now provide detailed information about the currently connected clients FEATURE Number of Devices within the DMS Explorer The interface branches within the DMS Explorer now display how many devices are present below them FEATURE IEEE1394 Bus Reset via the DMS Explorer Via the context menu of the IEEE1394 T001 it now is possible to force an IEEE1394 bus reset FEATURE Handling of big File Buffers at the Moment of the
29. X Tools in case of manual Window Modes In case the window mode is manual and more than one window is being opened at once there was a possibil ity to receive a crash during the termination of X Tools BUGFIX Possible Crash during the Export of Data of extended Data Types e g a Spectrum Exporting of data of extended data types via the Master Data System Explorer resulted in a crash of the X Tools Server and in a following hang of the X Tools Client BUGFIX Ignored decimal Places in case of advanced Export of extended Data Types The setting of the Decimal Precision parameter of the Advanced Export dialog of the Master Data System Ex plorer was ignored during the export of extended data types BUGFIX Bad Routing within the Analyzing Model Editor For Analyzing Functions which had a number of outputs which was equal to or grater than the number of inputs the link routing algorithm tried to start the link beneath the block instead of right the block side because the be neath route was shorter Now all Analyzing Functions are a bit higher so that some additional space is available at the bottom of each Analyzing Function BUGFIX Execution ID Filter of the System Log Viewer did not show the first matching Log Entry In case the System Log Viewer was configured to show only the log entries of a certain execution ID the first entry from the System Log file which would have matched the specified filter settings was not being shown
30. always ended up with a compiler error BUGFIX Destroyed Device Profiles of ION SIMATIC S7 300 T001 and ION SIMATIC S7 400 T001 Device Profiles of ION SIMATIC S7 300 T001 and ION SIMATIC S7 400 T001 devices could be destroyed in case they were opened and saved within a DPE ION SIMATIC S7 BUGFIX Possible Crash when using the Mouse Wheel within Monitoring Charts In case the option Keep Width of Curve Area synchronized was active and the mouse cursor was above an area where there was no y axis below it using of the mouse wheel could lead to a crash of the X Tools Client BUGFIX Time Difference between CH1 2 and CH3 4 5 6 of the IFN VIB ACC A different internal processing delay was used for CH1 2 and CH3 4 5 6 of the IFN VIB ACC Now the internal processing delay is equal for all six channels of this device BUGFIX Possible Crash during the Termination of the X Tools Server A timing issue could lead to a crash during the termination of the X Tools Server BUGFIX Missing Refresh of the Treatment of Status Codes Table The contents of the Treatment of Status Codes tables within the AME Standard T001 and the ASE Standard T001 were not updated when a new Analyzing Model or Analyzing Script was dragged into an editor which con tained another Analyzing Model or Analyzing Script already BUGFIX Missing Refresh of the Example Cell within Data Style Dialogs The displayed example was not updated after the Default
31. and X Tools Server was established via a network tunnel which changed the used communication ports it could happen that the X Tools Server refused the connection to the X Tools Client because for the X Tools Client the used ports seemed to be wrong Now the X Tools Server uses an improved mechanism in order to verify whether the connection is consistent English Release 2014 11 32 81 CMS X Tools Change Log CMS BUGFIX Wrong Stop Times of offline Data In case of data which produced a value only once each few seconds there was a possibility that the stored of fline data files contained wrong stop times BUGFIX Missing Start Events of offline Data In case slow data has been stored there was a possibility that no start event has been added to the offline data file As a result the visualization and possible post calculation of the data could show wrong information BUGFIX Wrong Date for sent Emails The emails which were sent by X Tools had an improper format for their date Therefore some email clients were unable to display the sent date which was transmitted by X Tools BUGFIX Possible Crash within Rsmpl The initialization of the Analyzing Function Rsmpl could cause an access violation and a following crash BUGFIX Possible Crash when loading huge amounts of small offline Data Files The X Tools Server could crash during the loading of huge amounts of small offline data files BUGFIX Offline Data loading after the re in
32. another search was performed and the Find Results table could be updated although this is not wanted in this situation BUGFIX Improper Log Entry from the Analyzing Function FormatString In case the Analyzing Function FormatString was called in sequential operating mode with a data as parame ter the resulting error message did not point out the real reason of the error BUGFIX Possible Memory Leak in Combination with simulated Devices Every attach of a simulated device could cause a small memory leak In case of frequent attaching and detach of simulated devices a rising of the used memory could be observed BUGFIX Possible Crash when loading of multiple offline Data Files with Interval only A crash could occur in case multiple offline data files were loaded simultaneously with a loading mode of Inter val only and when the X Tools Server was re initialized before the Loading Progress dialog disappeared BUGFIX Possible Loss of configured Locations in case of low Memory Conditions In case the internal initialization of a location failed either because of low memory conditions or because of other effects this location was removed from the file location file permanently BUGFIX Possible Crash in Combination with Device Profiles for CTN WatchGuard T001 Devices In case the CTN WatchGuard T001 was running in Watchdog operating mode and when it was monitoring the current Storage Profiles the X Tools Serve
33. any more In case a password field contains an empty password the password field stays empty and does not display stars also when it does not have the input focus CHANGE Improved Log Entry of the X Tools Client in case the X Tools Server shuts down In case a connected X Tools Server shuts down the system log of the X Tools Client now does not report un expected error conditions any more CHANGE Changed behavior of Start Pause Continue Stop for Directories Previously the start pause continue stop commands of directories applied the chosen operation to all files be low the selected directory but not to the sub directories of the chosen directory Now the chosen operation is applied to all files of the selected directory to all sub directories of the selected directory and to all of their files and sub directories CHANGE Improved Device Management Engine The internal architecture of the Device Management Engine has been improved in order to reduce the possibility of malfunctions dead locks and crashes in case of high system loads CHANGE Separation between the X Tools Server Startup and the improved Availability Previously the Automated Startup entry from the global options was used in order to configure whether the X Tools Server shall be started as service during the login of a Windows user or not at all When the X Tools Server was started as a service it automatically was monitored and restored in case of severe error
34. based operating modes any more CHANGE Modified reading of Input Data with Data Name Prefixes In case a data name prefix is defined within the Analyzing Model Analyzing Script this data name prefix is ap plied in all cases where an input data is accessed CHANGE Improved Handling and Notifications about incompatible Executables In case an incompatible executable is detected during the startup of X Tools an according log entry is created and the affected executable is not loaded X Tools terminates automatically in case the incompatible executa ble is a mandatory one and X Tools starts up with the remaining functionality in case the incompatible executa ble is an optional plug in CHANGE Analyzing Function GetVFrmSD can not run in Time Slice based Operating Modes The Analyzing Function GetVFrmSD does not support the time slice based operating modes any more As a result it also is not possible any more to use this Analyzing Function within Analyzing Models CHANGE Changing of the Category of MonSpmEnv The Analyzing Function MonSpmEnv has been moved from the category Envelopes to the category Spec tral CHANGE Improved Column Widths within the Tables of the SPE Binary T001 The automatic update of the width of the tables within the SPE Binary T001 has been improved so that the values from all present columns are visible whenever it is possible This is relevant epecially when there are some tables whose width
35. case only the frequency marker should be displayed without any harmonics From now on a value of 1 is used instead as a result a value of 2 displays the frequency marker plus 1 harmonic The internal representation is not changed thus Monitoring Views from previous versions still show exactly the same number of harmonics within the MTC yn T001 CHANGE Naming of X Tools X Tools has been renamed from SIPLUS CMS X Tools to CMS X Tools CHANGE Moving of the OutReady Output Argument of MonAlrmSpm The OutReady output argument of the Analyzing Function MonAlrmSpm has been moved to the end of the output arguments of this Analyzing Function Analyzing Models can be updated automatically after this change Analyzing Scrips which contain MonAlrmSpm must be updated manually CHANGE Update of the Standard Fast Analysis Location A few Analyzing Scripts of the Standard Fast Analysis location have been updated In addition several new Analyzing Scripts have been added to this location BUGFIX Improved Scroll Bars within the ODL Standard T001 Within the ODL Standard T001 the Offline Data Files tree could become much bigger than the actual height of the ODL Standard T001 itself As a result two vertical scroll bars were displayed and scrolling from the top of the tree to its bottom always required to use both scroll bars BUGFIX Wrong handling of not supported Trigger Data Types In case
36. case the source file was stored with a storage mode of Interval only and with an interval of bigger than 1 second BUGFIX Too little Performance for the Storing to Disk There was a wrong sleeping configured for the thread which is storing the data of Storage Profiles to the disk As a result the writing was too slow because it was idle most time compared to the amount of data buffers which were prepared for writing This too little performance also was noticeable through constantly increasing memory usage of the X Tools Server English Release 2014 11 17 81 CMS X Tools Change Log CMS BUGFIX Unwanted automatic Stop of Storages Profiles during the Startup of the X Tools Server In case of very low memory conditions at the startup of the X Tools Server it was possible that the STS has stopped a to be started Configuration File automatically instead of suspending it BUGFIX Possibility for storing of wrong Values There was a possibility that X Tools has stored single wrong values into its offline data files This happened in rare cases with online data that has been produced by Analyzing Models Scripts BUGFIX CPU usage of the X Tools Client while Starting a Device Profile While starting a Device Profile the CPU usage of the X Tools Clientis noticeable reduced BUGFIX Storing the State of Visibility of the Toolbar and of the Title Bar The state of visibility of the toolbars and title bars within Monitoring Views is stored
37. connected via a low bandwidth connection froze the X Tools Client for the amount of time which was needed in order receive all relevant information from the server In ex treme cases even the connection between X Tools Client and X Tools Server broke down BUGFIX Analyzing Models Scripts did not suspend in some Cases In case of action based and once operating modes Analyzing Models Scripts did not suspend in case their input data disappeared BUGFIX Wrong Check of the Input of high Values within the Manual scale t Axis Dialog In case a high value was input to the Manual scale t Axis dialog the according message box was not precise enough In addition there were situations where the Manual scale t Axis dialog did not accept any new inputs as correct inputs after it has received a too high input once BUGFIX Importing of Normalization Parameters failed sometimes After exporting of a Device Profile the import failed under certain conditions because the import of the normali zation parameters was incorrect BUGFIX Improper Handling of offline Data Files which contain only one Probe X Tools was unable to properly store and load offline Data Files which contained only one probe in the case that this one and only probe was before the start time of the offline data file BUGFIX Frozen X Tools Client while opening of Monitoring Views X Tools was frozen for the amount of time which was needed in order to collect all
38. data file contains detailed information about the time zone of the computer at which it was stored The stored time zone information can be used by e g the MTS in order to display each loaded offline data with its original time base settings BUGFIX Wrong Taking over of the Normalization within Device Profile Editors In case a Device Profile was opened within a Device Profile already and another Device Profile with different normalization settings was dropped into the same Device Profile Editor the normalization of the first Device Profile was taken over by the dropped one under certain circumstances BUGFIX Low Memory Conditions could disable the System Log permanently In case the hard disk of the System Log File became full the X Tools Server stopped to send system log entries to the X Tools Client New log entries also did not appear at the X Tools Client after the low memory condition of the hard disk had been solved BUGFIX Resizing of Columns within the System Log Viewer In case the System Log Settings table was updating it was not possible to resize the present columns in parallel BUGFIX Improper Handling of the Access Right for new File Locations New file locations became visible to all users even in case they did not have the access right New File Loca tions BUGFIX Wrong Title Bar of empty User Account Editors In case an empty User Accounts Editor was opened its title bar contained a wrong entry BUGFIX Too many
39. end up in a hang BUGFIX Missing Pre Trigger Time in case of the Storage Mode Interval only In case the storage mode of a data was Interval only and a pre trigger time was specified this pre trigger time was ignored and only one value before the start trigger time was added to the offline data file BUGFIX The License of Software I O Nodes is not released during the Re Initialization of the X Tools Server In case a license for a software l O Node e g ION SIMATIC S7 PN ION SIMOTION T001 was leased at the moment when the X Tools Server was re initialized this license was not released during the re initialization Therefore the following attempt to lease the license failed during the further re initialization of the X Tools Server BUGFIX Possibly wrong Header of csv exported 2 dimensional Data Within the header column of exported csv data the number of column captions was equal to the number of rows of the 2 dimensional data Now the number of column captions is equal to the number of columns BUGFIX Wrong Index Calculation within and Visualization of the output Data of the ANF TLC The index calculation was wrong therefore all values were counted one class too low In addition the visualiza tion of the output data within the Monitoring System has used classes instead of ranges BUGFIX Wrong Visualization of the output Data of the ANF RFC The visualization of the output data within the Monitoring System
40. fast shut down and restart of the X Tools Client could run into the issue that the X Tools Server was not restarted together with the X Tools Client because the X Tools Server was still shutting down during the restart of the X Tools Client In this case the X Tools Client thought that the X Tools Server is online al ready and did not start it at all Now the X Tools Client waits during its own termination until the X Tools Server has been shut down CHANGE Maximal Interval of all Analyzing Functions which output Data to the System Previously the maximal interval for the recode mode was 3 6 seconds Now the maximal allowed interval is 3600 seconds one hour CHANGE SndEmail can send to multiple Recipients Multiple recipients can be configured now to receive an email which is being sent via the Analyzing Function SndEmail CHANGE Opening of corrupted Analyzing Scripts Previously there was a chance that corrupted Analyzing Scripts were opened by the Analyzing Script Editor In this case the content of the corrupted file was displayed by the edit box of the Analyzing Script Editor Now the Analyzing Script Editor refuses to open corrupted Analyzing Scripts and it displays an according message box CHANGE Tool Tip of Devices with not unique Name or UIK In case the name or UIK of a device is not unique the tool tip of the affected device within the DMX shows the according information now CHANGE The Fit to Chart Operation
41. file the loading sometimes did not return any value and an offline data with zero probes was displayed within the MDX BUGFIX Wrong loading of Offline Data Files which contain only two special Probes In case of offline data files which contain only two probes and when one of these probes is before the start time and the other probe is after the stop time of the offline data file the loading sometimes did not return any value and an offline data with zero probes was displayed within the MDX BUGFIX Wrong loading of Offline Data Files in case of the changes based Loading Modes In case a loading mode of Changes only or Changes and Interval was used the preceding and following probes could be added wrongly especially in case multiple files were appended together BUGFIX Crash within the ANF OutputTCP In case one input of the ANF OutputTCP was not connected the Analyzing Function could end up in a crash BUGFIX Wrong Outputs from the ANF ConvVToB1D In case the precision was being set to a value different than Decimal64 the created output values were wrong BUGFIX Wrong Reset of the Graph Buffer of the MTC yt T001 There was a possibility that the graph buffer of the MTC yt TOO1 has been reset without a reason This could be observed especially in case longer time intervals multiple hours were displayed After each reset only the values which were available within the ring buffer of the displayed data could be d
42. for smaller Heights of Monitoring Charts The minimal allowed height of Monitoring Charts has been reduced to 40 pixels of space which must remain available for the Curve Area FEATURE Improved moving of Windows Whenever the size or position of a window shall be changed the resulting size and position of the window is indicated during the drag operation During the drag operation a green frame shows positions which can be applied after the drop and a red rectangle shows positions which can not be applied FEATURE Adding of a Standard Fast Analysis Location A location with several basic Fast Analysis Scripts is delivered together with X Tools now This location is add ed to the X Tools Server automatically during its first initialization and whenever the file location file must be recreated BUGFIX Possible Crash in case of exporting of Data with an Export Mode of Interval Only In case Interval Only was chosen as export mode within the Advanced Export dialog of the ODL Standard T001 and the to be exported data was an extended data type e g 1 dimensional buffer spectrum a crash could occur BUGFIX Improper Support for Precisions different to Decimal64 by some extended Data Types The following Analyzing Functions did not process precisions different to Decimal64 properly in all cases InB1D OutB1D InB2D OutB2D As a result the values which were processed by these Analyzing Func
43. in seconds internally During the next opening of the Monitoring View the capture delay value in seconds was displayed and the configured capture delay format was not considered BUGFIX Wrong Visualization within the MTC ynt T001 In case the to be visualized data contained amplitudes with a value of 0 the visualization for these amplitudes could be wrong BUGFIX Wrong Background Grid Interval within the MTC yt T001 Under certain circumstances there could be vertical lines of the background grid of the MTC yt T001 missing BUGFIX Zoom in and Zoom out do not compensate each other In case a zoom in operation was performed within a Monitoring Chart and a zoom out operation was per formed afterwards the scaling was not the same as before the zoom in operation again BUGFIX Missing Data Values within the MTC yt T001 In case the MTC yt T001 had to display big time intervals it could happen that the values within the last to be visualized pixel column were missing BUGFIX Unwanted Save Screenshot Context Menu Item within Screenshots In case of some operating systems the Save Screenshot context menu item could be present within screen shots that had been created via the Save Screenshot context menu item of Monitoring Charts BUGFIX Possible Crash of the X Tools Server during its Termination A certain timing could cause a crash of the X Tools Server during its termination BUGFIX Possible Crash o
44. is added to the Undo Redo Buffer now Each Fit to Chart operation now also increases the undo redo buffer counter and can be undone redone CHANGE Pausing and Continuing does not clear the Undo Redo Buffer any more The undo redo buffer counters are not being reset to 0 any more when the Monitoring Chart is being paused or continued Therefore the last zooming and shifting operations can be undone redone also in case there were pausing and continuing operations in between CHANGE The ANF RemoveData works case insensitive now The file name which is being passed to the ANF RemoveData is case insensitive now Thus RemoveData removes the created offline data of another Configuration File regardless to its upper lowercase spelling English Release 2014 11 29 81 CMS X Tools Change Log CMS CHANGE Improved Detection of corrupted Configuration Files The detection of corrupted Configuration Files has been improved Previously X Tools could crash in worst case in case it attempted to load a corrupted Configuration File CHANGE Improved Commonness for the Naming of the X Tools Client and the X Tools Server The naming of the X Tools Client and of the X Tools Server has been reviewed in order to become more common at all places like the log files tool tips and tree branches CHANGE Removing of meaningless Log Entries Analyzing Models and Analyzing Scripts do not output log entries about the Code Position or Occurred a
45. is bigger than the current width of the SPE Binary T001 English Release 2014 11 75 81 CMS X Tools Change Log CMS CHANGE Speed Optimizations for the processing of Analyzing Scripts The processing of large amounts of memory through Analyzing Scripts has been improved so that such Analyz ing Scripts can run up to 50 faster However for most operations Analyzing Models still have a significant speed advantage against Analyzing Scripts CHANGE Implicit Outputs of scalar Data do not chang the Properties of the scalar Data anymore In case a scalar data is present already and its value shall be updated by an Analyzing Script with an instruction like s Name 1 this operation updates the value of the existing scalar data but it does not change any of its other properties like precision unit CHANGE Averaging of the Values of the Main Frequency Marker In case the Main Frequency Marker of the MTC yn T001 is linked to a data the average value of this data over the period of time which belongs to the currently visualized spectrum is used as value for the Main Frequency Marker CHANGE New Directory Structure for the X Tools Service All files of the X Tools Service are put into the new directory Service which is found parallel to the Client and Server directories of the X Tools installation CHANGE Running of the X Tools Server without Windows Administrator Rights The X Tools Server can be started also w
46. message boxes has been reduced CHANGE New Icon for Storage Profiles which are in Status triggering The icon for Storage Profiles which are ins status triggering has been changed from a small sandglass overlay to a fully purple icon CHANGE Renaming of the Default Button The Default button has been renamed to Restore Defaults English Release 2014 11 45 81 CMS X Tools Change Log CMS CHANGE Correlation between the Order of Monitoring Charts and the order within the Cursor Tables The order of data within the cursor tables of Monitoring Views now is always directly dependent to the order of the currently present Monitoring Charts The data from the Monitoring Chart in the upper left corner is shown topmost within the cursor table the data from the Monitoring Chart in the lower right corner is shown bottom most CHANGE Changed Registry Path for the X Tools Tray Previous versions of the setup of X Tools have put the X Tools Tray to the registry path of the local user as a result it was only started in case the user who ran setup logged in to Windows The new version of the setup puts the X Tools Tray to the path of the local system in which case the X Tools Tray is started when any user logs in to Windows CHANGE Log Entry for the queuing of append overwrite export Operations Whenever an append overwrite or export operation is started via the ODL Standard T001 an according log entry is cre
47. new Analyzing Function MonFrBlck can be used in order to monitor the maximal free memory block of the specified process FEATURE Additional Analyzing Function MonSM The new Analyzing Function MonSM can be used in order to monitor the memory usage through the whole system all running processes FEATURE Additional Analyzing Function MonST The new Analyzing Function MonST can be used in order to monitor the CPU usage through the whole system all running processes FEATURE Additional Analyzing Function NTPOffset The new Analyzing Function NTPOffset can be used in order to monitor the time difference between the cur rent system time and the specified time server FEATURE Additional Analyzing Function SetStts The new Analyzing Function SetStts can be used in order to set the status of a variable to a defined value FEATURE Additional Analyzing Function GetNoV The new Analyzing Function GetNoV can be used in order to determine the number of values of an offline data English Release 2014 11 61 81 CMS X Tools Change Log CMS FEATURE Improved handling of a variable Number of Arguments through Analyzing Scripts In case an Analyzing Function which provides a variable number of arguments is used within an Analyzing Script and the call of the Analyzing Function does not contain the separator in order to mark the last of the configurable arguments an according warning is added to the system log FEATU
48. of the Short Name entry BUGFIX Bad handling of huge Numbers of Parameters within several Dialogs The behavior of the Provided Parameters table within several dialogs has been improved For example the height of this dialog has a defined maximum of Ye of its parent editor now and the maximal numbe rof parame ters is checked properly BUGFIX Forgotten Window Mode The currently chosen window mode e g Tabbed could be forgotten after closing and re opening of a work space window like the Main Management Workspace BUGFIX Small Signal Lights could not be moved within the MTC Mimic Board T001 In some cases it was not possible to move a signal light with a width and height of 1 background grid interval BUGFIX Wrong Indication of Errors within the DPE ION SIMATIC TDC T001 The Connector column within the Device Profile Data table of the DPE ION SIMATIC TDC T001 displayed all entries with red text even in case the according entries were available within the currently known address book BUGFIX Graphic Artefacts in Combination with the Classic Mode of Windows 7 In case the hardware accelerated DirectX grahics library was configured in X Tools and the desktop of the used Windows 7 PC was configured to run in Classic Mode grapic artefacts like a shadowed rectangle could be present within the Monitoring System BUGFIX Lost Inputs within the AME Standard T001 and UFE Standard T001 In case
49. of the X Tools Server BUGFIX Missing Log Entries about the resume of Device Profiles In case a Device Profile suspended and resumed very frequently the log entry about the resume did not occur more often than once each 60 seconds BUGFIX Missing Data from the simulated ION PROFIBUS DP Spy T001 The simulation of the ION PROFIBUS DP Spy T001 produced some of its data with a wrong frame check sum This data did not reach the internal ring buffers of X Tools because PROFIBUS DP packets with a wrong frame check sum are skipped BUGFIX Possible Hang of the X Tools Server during the start of a Device Profile with invalid Data Names In case it was attempted to start a Device Profile which contains invalid data names the X Tools Server could end up in a hang BUGFIX Possibility for invalid Data Names within several Device Profile Editors Some Device Profile Editors allowed to enter invalid names for message channels In case the Message Chan nel Contents table was used afterwards in order to define data with default names these default names also contained invalid characters BUGFIX Wrong Icon during the Drag amp Drop of Data from the MDX In case a Drag amp Drop operation of data from the MDX was going on and data was added to removed from the MDX before the operation was completed the mouse cursor icon could get trapped in one icon state In this situation the mouse cursor icon did not change any more no matter whether the mous
50. of the creation of the screenshot was smaller than the allowed minimal width the created screenshot could contain additional elements from outside the Monitoring View BUGFIX Possible wrong Position of Controls within the Chart Styles Dialogs In case the DPI setting of Windows was bigger than 100 or 96 DPI the position of the controls within the Chart Styles dialog could be shifted In this situation no editing was possible within this dialog BUGFIX Wrong Group for new t Axes within the MTC yt T001 In case a new MTC yt T001 was created through dragging of a new data from the MDX Explorer the newly English Release 2014 11 51 81 CMS X Tools Change Log CMS dropped could be put onto a new t axis although it should match the already existing t axis This issue could happen only in case the new MTC yt T001 was opened within a Monitoring View had been opened from an existing file previously BUGFIX Possible Error within the Conversion of absolute to relative Timestamps The output data of Analyzing Models and Analyzing Scripts which have offline data with absolute timestamps as input and offline data with relative timestamps as output could be empty in case of action based operating modes BUGFIX Possible wrong Determination of the first Timestamp of Analyzing Models and Analyzing Scripts In case the configured cycle time was bigger than 1 second the first timestamp might not be set to a determinis tic value Now
51. of the kurtosis coefficient FEATURE Additional Analyzing Function Range The additional Analyzing Function Range calculates the maximal extent of the online or offline input signals FEATURE Additional Analyzing Function Skewness The additional Analyzing Function Skewness calculates the skewness of the online or offline input signals based on the Fischer s definition of the skewness coefficient English Release 2014 11 13 81 CMS X Tools Change Log CMS FEATURE Additional Analyzing Function StandardDeviation The additional Analyzing Function StandardDeviation calculates the sample standard deviation of the online or offline input signals FEATURE Additional Analyzing Function StandardDeviationN The additional Analyzing Function StandardDeviationN calculates the standard deviation of the online or offline input signals FEATURE Additional Analyzing Function Variance The additional Analyzing Function Variance calculates the empirical variance of the online or offline input sig nals FEATURE Additional Analyzing Function VarianceN The additional Analyzing Function VarianceN calculates the variance of the online or offline input signals FEATURE Additional Analyzing Function FormatString The additional Analyzing Function FormatString produces text strings in prepared format which can be pa rameterized that certain fields in format string are replaced by parameter string FEATURE Additiona
52. precision CHANGE Limitation for simultaneously served XSI Clients The X Tools Server is not able to handle more than one XSI Client simultaneously Whenever there is an XSI Client connected already and another XSI Client attempts to connect the connection itself is allowed but an according warning is written to the log file In addition none of the requests from the second XSI Client are served by the X Tools Server BUGFIX Lost information about paused online Data within Monitoring Charts In case the online data within a Monitoring Chart was paused and the providing X Tools Server was discon nected and reconnected it was not possible any more to zoom into the paused data Now zooming into the paused online data is still possible in case there are only a few seconds between the disconnect and the con nect BUGFIX Unwanted copying of Escape Characters out of the System Log Whenever log entries were copied from the System Log Viewer unwanted escape characters could be pre sent within the clipboard BUGFIX Lost Value during storing of a 2 dimensional Histogram During the storing of a data of type 2 dimensional Histogram it could happen that the resulting offline data file contained one value less than it should BUGFIX The Analyzing Function Random did not reach the provided Maximum Value In case of a precision of Integer32 the Analyzing Function Random did not reach the provided maximum value Instead th
53. some cases For example when a Device Profile attempted to resume the other Configuration Files also attempted to resume before it was granted that the resume will succeed as a result all other Configura tion Files could attempt to resume and suspend again very frequently in situations where the resume of the Device Profile failed to succeed BUGFIX Wrong Description Name within Explorer Trees Within the explorer trees of X Tools all Configuration Files contained a sub item of name Profile Description For Monitoring Views Analyzing Models Analyzing Scripts and User Functions this was wrong and has been changed to View Description Model Description Script Description and Function Description BUGFIX Unwanted Stop of Storage Profiles In case a Storage Profile was started which did not contain any enabled definition within its Data table the English Release 2014 11 49 81 CMS X Tools Change Log CMS Storage Profile was stopped automatically Instead such a Storage Profile becomes suspended now and at tempts to resume automatically in case its file at the disk is being changed BUGFIX Wrong Resolution of the Analyzing Function Impulser The configurable times of this Analyzing Function were interpreted as pure Integers internally As a result the created result always had a length of a multiple of 1 second shorter impulses were not possible BUGFIX Wrong Handling of Boolean Input Buffers
54. ten times the same calculation but for ten different input and output signals FEATURE Data Name Prefix for Analyzing Scripts The Analyzing Script Editor now supports data name prefixes for input and output data Similar to the data name prefixes within Device Profiles the data name prefixes within Analyzing Scripts can be used in order to increase the reusability of Analyzing Scripts in case of environments with multiple similar tasks e g ten times the same calculation but for ten different input and output signals FEATURE Editing and Input Focus Change via the Keyboard The keyboard can be used in order to access buttons and to move the input focus from one control to another control Nearly all operations can be performed now without using the mouse FEATURE Data Export to the DIAdem dat Format The Advanced Export dialogs of the MDX and Offline Data Loader now allow to export offline data also to the DlAdem dat format FEATURE Advanced Time Base Settings for Offline Data Via the Chart Options dialog of Monitoring Charts and via the Monitoring View Parameters table of the Monitor ing View Editor also the time base setting Use the local time of the Offline Data is available now In case this time base is being chosen all loaded offline data is being displayed with the time base which it had when it was being stored FEATURE Advanced System Log Viewer After a new System Log File has been opened the entries now are be
55. the Data Format Selection for Bit Arrays For data which is defined as bit signal within a Device Profile the data format can not be switched between big little Endian any more CHANGE Disabling of the Record Mode Changes and Interval The Record Mode Changes and Interval has been disabled within Device Profiles CHANGE Connector Names of the ION SIMATIC TDC T001 The names of the connectors of the currently downloading address book of ION SIMATIC TDC T001 devices are not being displayed any more CHANGE Time Domain of IEEE1394 Devices The name of the time domain which is being used by IEEE1394 devices has been changed from Time Domain 01 to IEEE1394 CHANGE Default Buffer Size for Device Profiles of SIMATIC SIMOTION Devices In case a new Device Profile is being created for ION SIMATIC S7 300 T001 ION SIMATIC S7 400 T001 ION SIMATIC S7 PN or ION SIMOTION T001 devices the default size of the message channel is being set to the maximal possible size of each device now CHANGE Minimal allowed Cycle Time for Analyzing Models Analyzing Scripts The minimal allowed cycle time for Analyzing Models and Analyzing Scripts has been changed to 5 us 200 kHz The granularity of the cycle time also has been changed to 1 ns steps English Release 2014 11 14 81 CMS X Tools Change Log CMS CHANGE Supported COM Ports For the connection to serial port devices only the COM ports 1 9 were supported so far Now al
56. the first timestamp always is a multiple of the configured cycle time since 1970 01 01 00 0 00 GMT BUGFIX Possible suspending of big Analyzing Models or Analyzing Scripts during the Startup In case the loading of all contained Analyzing Functions and User Functions took more than a few seconds Analyzing Models and Analyzing Scripts could suspend directly after this loading because the last calculated value was too old Now the first calculation starts not at the moment of the start but at the moment after the successful loading of all Functions and therefore also very big Analyzing Models and Analyzing Scripts can start without suspending BUGFIX Delayed Initialization within the Analyzing Function TLC The Analyzing Function TLC did not perform a calculation during the first time slice at which its InReady argu ment was true instead the calculation always started at the next cycle and the first time slice was somehow wasted BUGFIX Possibly missing Data after Data Snapshots In case a Monitoring Chart contained both online and offline data the created data snapshot may contain only the present online data and wrong log entries about the present offline data may appear within the System Log BUGFIX Possibly missing parallel storing through Storage Profiles which have offline Data as Input Storage Profiles which use offline data as input were not able to perform more than 2 storings in parallel even in case the start trigger dat
57. the fix a Storage Profile reaches stopped not before all of its offline data are ready at the disk BUGFIX Possible Error during the Restart of a Storage Profile The restart of a Storage Profile could fail in case the stop of the Storage Profile took longer than a few seconds English Release 2014 11 72 81 CMS X Tools Change Log CMS BUGFIX Possible Stop of a Storage Profile through the Resource Manager of X Tools In case of low memory conditions the resource manager of X Tools can suspend a Storage Profile In case the stopping of the Storage Profile took longer than a few seconds during the next resume attempt the Storage Profile could end up suspended forever BUGFIX Possible increased Memory Usage through the Analyzing Function MonCF In case the Analyzing Function MonCF was called less often than there were changes of the state of Configu ration Files within the system it could consume more and more memory because the Analyzing Function has collected all state changes and could deliver only one per call BUGFIX The Analyzing Function Sleep could delay the suspending of an Analyzing Script In case an Analyzing Script was processing the Analyzing Function Sleep at the moment when it should sus pend it could end up in the status suspending until the specified amount of time had been slept In applica tions with very log sleep intervals this could cause a noticeable hang of the Analyzing Script BUGFIX
58. the value of an input argument of an ANF USF was in editing mode and the left mouse button was clicked somewhere outside the edit box the entered value was lost BUGFIX Missing vertical Background Grid within the MTC yt T001 In case of certain combinations of offline data and displayed time intervals some of the vertical background grid lines and the according lables at the x axis could be missing within the MTC yt T001 BUGFIX Double Click onto Legend Entries might not work in Combination with manual Widths In case the width of a Monitoring View was defined manually and the horizontal scroll bar was not at its very left position it might have been impossible to open the Data Style dialog via a double click onto a legend entry English Release 2014 11 77 81 CMS X Tools Change Log CMS BUGFIX More tolerant reading of csv Files with offline Data In case a to be loaded csv file with offline data contained too little semicolons within its data rows the loaded offline data could end up with only O probes BUGFIX Wrong default Full Name and Short Name within the AME Standard T001 In case a configurable input argument like In0 of the Analzing Function Add was added as parameter of the Analyzing Model the created default full and short names were like Input and In instead of Input0 and In0 BUGFIX Checking of too many Events through the Input Analyzing Functions Each input Analyzing Function did che
59. through the Analyzing Function OutTCP The Analyzing Function always transmitted 8 Boolean values as one byte and the byte could get only the val ues 0 or 1 Now each Boolean value is transmitted as separate byte and again can get the values 0 or 1 BUGFIX Too high CPU Usage for the Visualization within the MTC yx T001 The MTC yx T001 used too many CPU resources in case it had to visualize online data which was recorded with high sample rates e g 192 kHz The CPU usage for this use case has been reduced significantly so that also very fast online data can be visualized by the MTC yx T001 BUGFIX Possible Hang of the X Tools Client because of the CTN WatchGuard T001 The Device Profile of CTN WatchGuard T001 devices could hang in a way which also could cause the X Tools Client to hang after the user tried to start or stop the Device Profile BUGFIX Inaccurate Code Positions within Error Messages from Analyzing Scripts In previous versions of X Tools Analyzing Functions reported a code position which matched the start of the Analyzing Function always Now the system can report the exact code position of the argument which has caused the error In case the error is not caused by a certain argument the system still returns the start of the Analyzing Function as code position BUGFIX Missing Offset Compensation for Devices of type ION Analoginput T001 The internal offset compensation for Devices of type ION AnalogInput T001 did not work
60. time which is before the real begin time BUGFIX Analyzing Functions which contain Parameters as Input Arguments could not be used within Time Slice based Analyzing Scripts An internal error within the parsing of input arguments let the interpreter think that somebody wants to change the constant input argument Changing of constant input arguments is not allowed therefore the Analyzing Script was suspended with an according log entry BUGFIX Possible Crash because of uninitialized Pointers within Analyzing Functions The following Analyzing Functions could cause a crash because the could access uninitialized pointers in cer tain situations ConvSpm GenAlrmBnd and TLC English Release 2014 11 41 81 CMS X Tools Change Log CMS BUGFIX Opening of multiple Dialogs from the X Tools tray icon It was possible to call the context menu of the X Tools tray icon multiple times and to open multiple X Tools Server Status and X Tools Connectivity dialogs via this way BUGFIX Possible Crash from storing of Extended Data Types A crash could occur in cases where the amount of memory which is needed to keep one probe of an extended data type e g a spectrum or a 1 2 dimensional buffer exceeded the currently configured STS allocation size BUGFIX Possible Hang within Interface Profile Editors A hang of the X Tools Client could occur in case the last empty line of an Interface Profile was first copied via lt Ctrl g
61. to show a graphical view of the process together with its relevant key values FEATURE Additional Analyzing Function GetNumberOfPoints The new Analyzing Function GetNoP can be used in order to determine the number of points of an offline da ta FEATURE Additional Analyzing Function ConvertToVDMA The new Analyzing Function ConvToVDMA can be used in order to convert the current value of any Integer or decimal data into the according VDMA code for OK warning critical and defect FEATURE Additional Analyzing Function IsPrcsBsy The new Analyzing Function IsPrcsBsy can be used in order to check whether the specified process reacts to Window messages whether it is busy or not FEATURE Additional Analyzing Function IsPrcsPrsnt The new Analyzing Function IsPrcsPrsnt can be used in order to check whether the specified process is pre sent currently FEATURE Additional Analyzing Function MonPC The new Analyzing Function MonPC can be used in order to monitor any of the performance counters which are maintained by Windows FEATURE Additional Analyzing Function MonPM The new Analyzing Function MonPM can be used in order to monitor the memory usage of the specified pro cess FEATURE Additional Analyzing Function MonPT The new Analyzing Function MonPT can be used in order to monitor the CPU usage of the specified process FEATURE Additional Analyzing Function MonFrBlick The
62. within the AME Standard T001 All places which support the Add Parameter and Remove Parameter context menu items now also support the Go to Parameter context menu item which allows to highlight the according parameter within the Provid ed Parameters table FEATURE Go to Input Output Interface Context Menu Item within the UFE Standard T001 All places which support the Add Input Interface and Remove Input Interface context menu items now also support the Go to Input Interface context menu item which allows to highlight the according input interface within the Provided Input Interfaces table In addition all places which support the Add Output Interface and Remove Output Interface context menu items now also support the Go to Output Interface context menu item which allows to highlight the according output interface within the Provided Output Interfaces table FEATURE Additional Analyzing Function CreateCF The new Analyzing Function CreateCF can be used in order to create a copy of an existing Configuration File without changing of the default values of the parameters which are provided by the to be copied Configuration File FEATURE Additional Analyzing Function CreateCFEx The new Analyzing Function CreateCFEx can be used in order to create a new Configuration File out of an already existing Configuration File The parameters which are passed to CreateCFEx
63. 001 MTC ynm T001 und MTC yx T001 did not apply all standard chart op tions when new Monitoring Charts of these types were opened For example in case the standard visibility of the legend was configured to be hidden the according setting was correct within the Chart Options dialog but the legend still was visible BUGFIX Double Error Message in case DirectX is not available On systems which do not support DirectX the according error message could be displayed twice in a row in stead of only once BUGFIX Possibly missing Log Entry about the Resume of a suspended Configuration File In case of resume operations which include a full stop and start of the Configuration File the actual log mes sage about the resume could be missing In such a case the last visible log entry is about the stop of the Con figuration File although the Configuration File is being resumed successfully and fully operational BUGFIX Unwanted Log Entries from the X Tools Service Under certain configurations the X Tools Service was able to create log entries each 30 seconds In this case it created about 2 MBytes of log file per day BUGFIX IEEE1394 Bus Reset caused by the ION PROFIBUS DP Spy T001 During the restart of the Device Profile of ION PROFIBUS DP Spy T001 devices the data supervision could send an invalid command sequence to the device In some cases the ION PROFIBUS DP Spy T001 could issue an IEEE1394 bus reset as reaction to this invalid command seque
64. ANGE Notification of very low Memory Conditions Previously a message box could be displayed in case of low memory conditions Now low memory conditions are ignored in case they can cause only temporary effects and low memory conditions lead to a crash in case they point to a severe error CHANGE Advanced appending overwriting and exporting of offline Data The handling of the preceding and of the following probes has been improved for all interval based appending overwriting and exporting operations CHANGE Removing of X Tools Server ini The file X Tools Server ini has been removed because it is not needed any more In addition the information about the main path has been removed from the global options of the X Tools Server CHANGE Faster editing within the Analyzing Model Editor Previously a message box was displayed to the user in case the user tried to connect two inputs or two outputs Now the second selected connector removes the selection from the previously selected connector automatical ly there is no message box any more and the editing can continue directly CHANGE Reloading of Device Profile Parameters within the DPE ION SIMATIC S7 Whenever the device profile parameters are being reloaded by this Device Profile Editor also the device type of the Device Profile is set to the device type of the current target device CHANGE Improved Shutdown of the X Tools Server through the X Tools Client Previously a
65. Analyzing Function H2D has set its OutReady output argument to true whenever the current calculation time was negative BUGFIX Wrong handling of the minimal Interval through logarithmic Axes In case the mouse lasso was used in order to zoom into a logarithmic axis to an interval which is below the min imal allowed interval the status of the axes after the zooming operation could become undefined BUGFIX Possible Crash of the X Tools Client during the automatic restoring of Monitoring Views In case Restore the Monitoring Views from the last Session was configured to Restore the Monitoring Views from the last Session during the Startup of the X Tools Client and a Monitoring View was open during the ter mination of the X Tools Client the following startup of the X Tools Client could end up with a crash BUGFIX Crash of the X Tools Client instead of the Conversion of a MTC yt TOO1 to MTC yx T001 The X Tools Client crashed in case the data from the legend of a MTC yt T001 was dragged and dropped onto the t axes BUGFIX Wrong updating of the Values of Input Arguments within AME and UFE In case the value of an input argument was changed within the AME Standard T001 or UFE Standard T001 and lt Enter gt was not pressed in order to end the editing the entered value was assigned to the next clicked input argument instead of assigning it to the edited input argument BUGFIX Possibly wrong Log Entries from MonAlrmSpm In
66. BUGFIX Not matching Stop Times for the Offline Data Files of a suspended Storage Profile In case a Storage Profile has been suspended its offline data files received slightly different stop times English Release 2014 11 9 81 CMS X Tools Change Log CMS BUGFIX Wrong Code Position within Error Log Entries from Analyzing Scripts The code positions within log entries which reported an error were correct only for the Analyzing Function which had been called first and where wrong for all other Analyzing Functions 2 2 X Tools V 03 01 gt X Tools V 03 02 The following changes have been introduced in X Tools V 03 02 FEATURE Default Values within the Data Style Dialog of Monitoring Charts The Data Style dialog of Monitoring Charts provides a possibility to choose Default for any of the settings there FEATURE Aligned Width of the Curve Area of Monitoring Charts In case of a Monitoring View Editor which contains multiple Monitoring Charts the width of all Curve Areas of all Monitoring Charts can be aligned FEATURE Synchronized Cursors within Monitoring Charts In case a Monitoring View contains multiple Monitoring Charts the cursors can be synchronized among all Mon itoring Charts now FEATURE Configurable Size of calculated Offline Data The maximum size of data created by Output Analyzing Functions was fixed to 50 MBytes Now the maximum size is configurable FEATURE Advanced automatic arrange Possibilities for Win
67. CHANGE Improved routing of Links within Analyzing Models and User Functions The automatic routing of links has been improved within the AME Standard T001 and UFE Standard T001 In addition the context menu items Reroute Links automatically and Reroute Link automatically can be used and it also is possible now to move single segments of a link manually CHANGE Faster stopping of Storage Profiles In case a Storage Profile is stopped through the user it always is stopped within not more than 3 seconds CHANGE Moving to V 1 4 0 of the OPC UA C SDK X Tools has been updated in order to use the current version of the OPC UA C SDK V 1 4 0 CHANGE More tolerant reading of csv Files with Offline Data The check of the syntax of to be read csv files has been modified so that also several cases of too little and or too many semicolons do not keep X Tools from importing of the contained offline data values BUGFIX Set as Standard did not work for the Time Base of Monitoring Charts Pressing of the Set as Standard button within the Chart Options dialog of a Monitoring Chart did not work for the configured Time Base value Instead of the set value each new Monitoring Chart was created with a value of Default BUGFIX Missing suspend of an Analyzing Script whose Input Data gets removed Under certain conditions an Analyzing Script whose input data got removed did not suspend Instead the Ana lyzing Scrip
68. CMS X Tools Change Log CMS SIEMENS Preface 1 Change Log 2 List of Abbreviations 3 CMS X Tools Change Log Contact Information 4 English Release 2014 11 English Release 2014 11 1 81 CMS X Tools Change Log CMS Safety Guidelines This document contains notices which you should observe to ensure your own personal safety as well as to avoid property damage The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring to property damage only have no safety alert symbol Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution Used with the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury gt gt gt Notice Used without the safety alert symbol indicates a potential situation which if not avoided may result in an undesirable result or state When several danger levels apply the notices of the highest level lower number are always displayed If a notice refers to personal damages with the safety alert symbol then another notice may be added warning of property damage Qualified Personnel The device system may only be set up and operated in conjunction with this documenta
69. Connection Attempts In case the ports which are reported by the currently connecting client and the ports which are seen by the X Tools Server are different an according entry is added to the system log Another log entry is added after the X Tools Server has verified whether the connection is valid although the port information is mismatching which can be the case when VPNs or other methods of port translation are being used BUGFIX Wrong coloring of Slider Bars The color of each slider always shall match the color of the topmost data which is assigned to the slider within the legend In some situations this rule was not kept BUGFIX Possible Errors with the Analyzing Functions GenAlrmBnd and MonAlrmSpm The Analyzing Function MonAlrmSpm did not recognize all changes of the alarm bands which were created by GenAlrmBnd as a result MonAlrmSpm could operate on outdated alarm bands This could occur especially but not only also in case GenAlrmBnd and MonAlrmSpm were running with different cycle times and or in case GenAlrmBnd was enabled and disabled with an interval different to the cycle time of MonAlrmSpm BUGFIX Lost Information about Storage Profiles in Status Triggering After closing and re opening of the STS Explorer the icon of Storages Profiles never showed whether it is cur rently triggering or not Instead the standard icon for Started was displayed BUGFIX Possibility of permanent suspend of D
70. E Export to csv with one Probe per File The Advanced Export dialogs of the MDS Explorer and of the ODL Standard T001 now allow to configure the File Creation Mode Via this setting the export can be configured to either create one file for all of the to be exported probes pairs of timestamp value or to create multiple csv files where each file contains only a sin gle probe FEATURE Configurable Priority of the X Tools Server The priority of the process of the X Tools Server now can be configured via the Process Priority setting from the global options FEATURE Calculations within the MTC yn T001 The toolbar of the MTC yn T001 has received the additional button Calculate Via the context menu of this English Release 2014 11 55 81 CMS X Tools Change Log CMS button automatic calculations can be configured so that the MTC yn T001 displays all of its contained spectrums with a unit of m s acceleration mm s velocity or mm displacement FEATURE Improved zooming at auto scaled Axes In case an axis is configured to automatic scaling the automatic scaling is turned off automatically at the mo ment when the user zooms or shifts this axis manually FEATURE Logarithmic scaling of Axes The axes of the following Monitoring Charts can be switched to Logarithmic now MTC yn T001 x and y axis MTC ynm T001 x y and z axis MTC yt T001 y axis and MTC yx T001 x and y axis FEATURE Support
71. English Release 2014 11 80 81 CMS X Tools Change Log CMS 4 Contact Information Should you have any questions concerning the software application please refer to the Industry Sector Tech nical Support Department Siemens AG Industry Sector Phone 49 0 911 895 7222 Monday to Friday 09 00 am to 05 00 pm CET CEST Fax 49 0 911 895 7223 Internet www siemens de automation service amp support Thank you for using one of the above mentioned contacts to ensure your inquiry is registered and can be pro cessed English Release 2014 11 81 81
72. GFIX Not symmetric Output of the GenWF Analyzing Function In case of rectangular output functions the GenWF Analyzing Function did not produce a symmetric output in rare case This issue occurred sometimes when the specified frequency was an exact multiple of the cycle time BUGFIX LNK LED of IEEE1394 Devices is not being turned on In rare cases it was possible that X Tools has established the connection to an IEEE1394 device without turning its LNK LED on In such a case the IEEE1394 device was working properly but its LNK LED did not indicate any activity BUGFIX Crash during the renaming of a Device In case the user started to rename a device and this device was detached afterwards a crash could occur when the user wanted to finish the renaming BUGFIX Improper Handling of Time Resets In case multiple devices have shared the same time domain and one of these devices has detected a problem with the time synchronization the other devices did not process the following time reset properly As a result the time synchronization between the affected devices could be lost BUGFIX Time Errors from the simulated ION ARCNET Spy T001 The simulation of the ION ARCNET Spy T001 was producing timestamp errors from time to time BUGFIX Never resuming Storage Profile in case of low Memory Conditions The calculation of the amount of RAM which is available for the Storage System contained an error which al ways reported too little available
73. Mode In very rare cases it was possible to set up a layout of windows which caused a hang or crash of the X Tools Client BUGFIX Possible Crash in case of extremely fast suspending and resuming of multiple Device Profiles In case multiple Device Profiles were constantly suspended and resumed very fast e g within less than a sec ond there was a possibility to end up in a crash of the X Tools Server BUGFIX Possible Hang during the Execution of Analyzing Models Scripts with extreme Memory Load In case of Analyzing Models and Analyzing Scripts which consume a very big amount of memory there was a possibility to end up in a hang of X Tools BUGFIX Possible Crash in Environments with hardware accelerated OpenGL and Remote Desktop There were some drivers which produced a crash in case the X Tools Client was configured to use OpenGL 1 1 hardware accelerated as graphics library The crash occurred in case the X Tools Client was started local ly first and via Remote Desktop afterwards The bugfix detects such situations and avoids the driver to crash BUGFIX The x Axes of the MTC yn T001 could not be removed The context menu item Remove Axis did not have any effects for the x axes of the MTC yn T001 BUGFIX Ignored Undo Redo Buffer Size after re opening of a Monitoring View After re opening of an existing Monitoring View the configured undo redo buffer size was ignored by the Moni toring Chart although it was written correct
74. RE Reading of Strings from OPC UA Servers Also data of type string can be read from OPC UA servers from now on FEATURE Providing of Strings to OPC UA Clients Also data of type string can be provided to OPC UA clients from now on FEATURE Adding of the Default Output Data Precision to Analyzing Models and Analyzing Scripts The new option Default Output Data Precision has been added to the Analyzing Model Parameters and Analyzing Script Parameters table of the AME Standard T001 and ASE Standard T001 It can be used in order to configure the precision of all output Analyzing Functions whose Precision input argument is set to Default FEATURE Smart decimal Places The new global option Smart decimal Places can be configured for the X Tools Client When it is turned on the system automatically extends the number of displayed decimal places so that the first non zero digit after the comma becomes visible FEATURE New Time Interval Format None use shortest Time Interval The new time interval format from the Offline Time Configuration table of Analyzing Models and Analyzing Scripts can be used in order to automatically determine and use the time interval of the input data FEATURE Support for Data of Type String for the ION SIMATIC TDC T001 Data of type String now can be acquired from devices of type ION SIMATIC TDC T001 FEATURE New Command Line Argument
75. a contained additional start events BUGFIX Wrong Format of the csv Export of 2 dimensional Buffers The values in x and z direction where mixed for the csv export of 2 dimensional buffers which could lead to wrong values within the exported csv file BUGFIX Files and Directories can not be deleted from Offline Data Locations of Type csv Via the ODL Standard T001 it was not possibly to delete files and directories from offline data locations of type CSV BUGFIX Possibly missing Value within Offline Data Files In case a Storage Profile was configured to use offline data as input the created offline data file could be stored without the last value from the original offline data This behavior occurred in case the last value of the input data was exactly at the moment of the stop time of the data BUGFIX Unwanted Changes within the Start Event and Stop Event Tables of the SPE Binary T001 Whenever a new data was dropped onto the Start Event and Stop Event tables of the SPE Binary T001 the value of the Threshold Type was automatically changed back to the default value BUGFIX Dropping of a lot of Data into the Monitoring System may not show all of the dropped Data In case more than 32 data were dropped into the Monitoring System multiple Monitoring Charts were opened this is correct However only the first Monitoring Chart got some data inside all other Monitoring Charts re mained empty
76. a data of not supported type e g a Spectrum was used as data for the start or stop trigger of a Storage Profile huge amounts of log entries were created and the Storage Profile did not suspend properly BUGFIX Cancel Loading may not work within the DPE ION SIMATIC TDC T001 The Cancel Loading button of the DPE ION SIMATIC TDC T001 did not cancel the loading of the address book BUGFIX Append and Advanced Append do not work with overlapping Stop and Start Times In case the output modes Append or Advanced Append were used by an output Analyzing Function the parent Analyzing Model Analyzing Script suspended in case the stop time of the already present offline data was identical to the start time of the to be appended offline data BUGFIX Possible Crash during the Initialization of the OPC UA Interface The X Tools Server could end up with a crash in case the initialization of the OPC UA interface returned an error BUGFIX Possibly lost Synchronization between Time Axis of one Group Dropping of another offline data into a Monitoring View which contained offline data already could end up with two t axes which were within the same group e g G1 but which displayed different time intervals English Release 2014 11 63 81 CMS X Tools Change Log CMS BUGFIX Possible Crash after pressing of Clear Log within the System Log Viewer Clearing of the currently displayed log entries via the Cle
77. alculation Time Under certain circumstances the internal buffers which are used during the processing of Analyzing Models and Analyzing Scripts could be re initialized too often In worst cases this could cause a suspend of the Analyzing Model Analyzing Script because it was not able to perform all calculations within the available amount of time BUGFIX Too high CPU Usage of Analyzing Models with very slow Cycle Times The X Tools Server could cause a high CPU usage during the start of an Analyzing Model The high CPU us age could be observed between the start of the Analyzing Model and the first calculated cycle of the Analyzing Model BUGFIX Possible Corruption of a User Function when it is converted from an Analyzing Model In case an Analyzing Model with provided parameters has been converted into a User Function the User Func tion could be corrupted so that it was not possible any more to open or to use it afterwards BUGFIX Possible reading of too old Values from the Ring Buffer of an online Data In case the ring buffer of an online data was filled up once and afterwards somebody e g the XSI dll started to read data from this ring buffer the returned data values could be from the beginning of the available time inter val instead of from the requested start time BUGFIX Possible Hang of the X Tools Server because of an interrupted Data Streaming In case an XSI client has disconnected from the X Tools Server while the data strea
78. all be updated or whether a new parallel installation shall be cre ated FEATURE Increased maximal Number of Points In addition to the so far maximum of 65536 values also input buffers with 131072 and 262144 values are sup ported by the Analyzing Functions FFT AppBhann AppBlack AppBlett App Hamm AppHann Avg Spm Cpstr and EnvHIb from now on FEATURE Import of iba dat Files iba users who have ibaFilesLite dll installed at their computer can use X Tools in order to import the data from iba dat files FEATURE Adding of missing Keyboard Shortcuts The standard keyboard shortcuts like lt Ctrl gt lt N gt lt Ctrl gt lt S gt lt Ctrl gt lt O gt lt Ctrl gt lt F4 gt lt Ctrl gt lt P gt lt Ctrl gt lt Y gt and lt Ctrl gt lt Z gt have been added to all editors and to all explorer trees FEATURE Improved switching between the MTC yn T001 and MTC ynt T001 Whenever a MTC yn T001 is switched into a MTC ynt T001 the resulting MTC ynt T001 remembers all set tings from the MTC yn T001 As a result the MTC ynt T001 can be switched back into a MTC yn T001 later and the resulting MTC yn T001 is identical again to the original MTC yn T001 Consequently the MTC yn T001 also remembers all settings from the MTC ynt T001 CHANGE Removing of Support for Time Slice based Operating Modes from the Analyzing Function GetVFrmSD The Analyzing Function GetVFrmSD does not support time slice
79. any more CHANGE Enabling of GenWF also for action based Operating Modes The Analyzing Function GenWF now can be used in action based operating modes also CHANGE Adding of unified Version Information to all Configuration Files All Configuration Files now contain the version of X Tools which has been used when the Configuration File was saved the last time CHANGE Unified Icons within the Select File Dialog The Select File dialog now uses the same icons for locations directories and Configuration Files as all of the explorer trees CHANGE Visualization of empty Units within Monitoring Charts Within the legend and within the cursor tables of all Monitoring Charts an entry like is being displayed for all data which does not provide a unit CHANGE Hiding of the Connection Type Column within the MPE Standard T001 The option UDP has been removed from the Connection Type column of the MPE Standard T0071 In addi tion this columns is hidden by default now CHANGE Improved Performance of the PROFIBUS DP T001 Interface The performance of the data transmission from the PROFIBUS DP T001 interface to the ring buffers of online data has been improved significantly CHANGE Less Resource Usage during loading of Offline Data Files The loading of offline data files now only uses the CPU in case no other task is using it Thus loading of offline data files may need a little bit longer now but does
80. ar Log button of the System Log Viewer could cause a crash of the X Tools Client BUGFIX The OPC UA Client could not receive any Data from OPC UA Servers A wrong timeout setting has keep the OPC UA client of X Tools from connecting properly to OPC UA servers As a result the OPC UA client could not read the available online data from OPC UA servers BUGFIX Global Option Files from Versions before V 04 00 IR2 could not be opened In case the Global Options File from a version of X Tools before V 04 00 IR2 was opened its contained global options were not available BUGFIX Possible Crash within the Storage System The X Tools Server could end up with a crash BUGFIX Possible Memory Leak within Storage Profiles In case a Storage Profile was configured to a start trigger like Value gt Threshold and the pre trigger time was rather long it could happen that the Storage Profile was unable to store any values to disk In this situation the Storage Profile also could start to consume more and more memory BUGFIX Possible Memory Fragmentation through output Analyzing Functions Output Analyzing Function which have output offline data could cause significant fragmentation of the address space of the X Tools Server because at the start of the Analyzing Model Analyzing Script they typically have allocated more memory than there was needed for their calculation result BUGFIX Scroll Bars within a MVE Standard T001 may not work properly
81. ard T001 at a moment where this editor did not show the vertical scroll bar the X Tools Client could crash BUGFIX OPC UA is not available The OPC UA functionality could not be used because the OPC UA DLLs could not be loaded properly BUGFIX Possible Crash of the X Tools Server A certain timing between the creation of data for an automatic report and the preparation of the automatic report could be affected by a race condition As a result the X Tools Server could attempt to access already freed memory and it could crash afterwards BUGFIX Wrong suspend of an Analyzing Model to which a String is passed In case a string was passed to an Analyzing Model via the Analyzing Function StartEx and in case this string contained a character which is not allowed within a data name the Analyzing Model suspended The according log entry that pointed that the passed parameter had an invalid format BUGFIX Possibly corrupted Data in case an older Time Interval is appended to a newer Time Interval The internal state of an offline data could become corrupted in case older parts were appended to already pre sent newer parts As a result some parts of the data may have been not displayed any more by the Monitoring System BUGFIX Offline Data with future Timestamps can not be stored exported via the MDS Explorer In case offline data with future timestamps should be stored or exported via the MDS Explorer the stor ing exporting did not complete b
82. as stop any more In addition the status code which is returned by these Analyzing Functions provides basic information about whether the target Configuration File was running normally before the stop or not CHANGE No output of the calculated Filter Frequencies through the Analyzing Function Orbit The Analyzing Function Orbit does not output the calculated filter frequencies any more because there are use cases where the filters have to be recalculated all the time and these use cases caused constant adding of log entries In addition the Analyzing Function does not output a log entry more often than once per minute in case it was unable to calculate the filter frequencies with a damping of greater than 35 dB CHANGE Changes about the automatic Update of Analyzing Models and User Functions In case the Analyzing Model or the User Function which shall be opened by the AME Standard T001 or UFE Standard T001 contains functions with conflicting interface definitions the displayed message boxes do not contain a list of the outdated functions any more In addition only one message box is displayed in case of up dates which can be completed successfully instead of two message boxes in the past The AME Standard T001 and the UFE Standard T001 also highlight functions with outdated interfaces now through a red back ground color for their lower rectangle Finally in case one function can not be updated the update is not can celled as a whole in
83. ase a change of the system time is detected now all of the currently started Configuration Files of the X Tools Server are restarted in a defined order This approach reduces the number of errors during the restart which could occur because of unavailable data CHANGE Reduced Memory Usage for the editing of Device Profiles for ION SIMATC TDC T001 Devices Opening of the Device Profile for an ION SIMATIC TDC T001 devices does not fill the whole Address Book tree any more Instead the tree is filled only when a branch is expanded through the user which gives a signifi cant smaller memory usage and faster loading times especially in case of bigger address books CHANGE Improved storing of preceding and following Probes through Storage Profiles The rules for adding of preceding and following probes have been defined more clearly and the implementation has been updated in order to follow these rules CHANGE Improved loading of offline Data Files with Gaps in between In case offline Data Files from different periods of time were loaded with the loading modes Interval only or Changes and Interval the loading attempted to fill also the gap between both intervals with values This could cause significantly bigger offline data files on the one hand and provided a wrong impression about the values of the loaded data for the time interval of the gap for this time interval the system does not have any infor mation available CHANGE
84. asic visualization and analysis tasks This edition does not handle any kind of online data and can not connect to any kind of devices FEATURE Support for Data of Type String Data of type String now can be acquired from devices of type ION SIMATIC S7 PN ION SIMATIC S7 300 T001 ION SIMATIC S7 400 T001 and ION SIMOTION T001 Data of type String also can be input and output by Analyzing Models and Analyzing Scripts from now on and it is possible to store load export such data There is no separate Monitoring Chart for the visualization of this data type at the moment FEATURE Additional Analyzing Function InputString The new Analyzing Function InStr can be used in order to read data of type string from the system and to use it within Analyzing Models and Analyzing Scripts FEATURE Additional Analyzing Function OutputString The new Analyzing Function OutStr can be used in order to write data of type string to the system out of Ana lyzing Models and Analyzing Scripts FEATURE Default Values of Analyzing User Functions within the ASE Standard T001 In case the lt Alt gt key is hold down while an Analyzing Function or User Function is inserted into the ASE Standard T001 the dropped Function is inserted together with its default values and additional comments about each of its input and output arguments FEATURE Formula Editor within the MVE Standard T001 The Formula Editor
85. ate control scripts which are widely independent to the current symbolic name of their location FEATURE Reports out of the AME Standard T001 and UFE Standard T001 The context menus of the AME Standard T001 and UFE Standard T001 now provide the Print Report and English Release 2014 11 43 81 CMS X Tools Change Log CMS Save Report items which can be used in order to print or save a report of the currently opened Analyzing Model or User Function FEATURE Restart of Configuration File The context menu of each started Configuration File now contains the entry Restart which can be used in or der to restart stop and start the Configuration File with one single operation FEATURE Data Snapshot for complete Monitoring Views The Store Data Snapshot button from the tool bar of Monitoring Charts now can be used in order to store a data snapshot only for the current Monitoring Chart or for the whole Monitoring View FEATURE Improvements of the X Tools Server Interface XSI The X Tools Server now allows multiple XSI Clients to connect to it simultaneously In addition the compres sion of the data exchange between X Tools Server and XSI Clients allows using of the available bandwidth more efficiently now the compression is available only for XSI Clients of V 03 05 or higher FEATURE Append and Overwrite for Output Analyzing Functions The output Analyzing Functions within Analyzing Models and Analyzing Script
86. ated immediately The log entry is added also in case another longer lasting ap pend overwrite export operation is in progress at the moment CHANGE Improved Format of Device Setup Files for ION SIMATIC TDC T001 Devices The format of Device Setup Files for ION SIMATIC TDC T001 devices has been optimized Such Device Setup Files are now read and written about 10 times faster In order to convert a Device Setup File from the old to the new format open the Device Profile which uses the Device Setup press the button of the Device Setup File parameter within the Device Profile Parameters table and choose Save As Overwrite the already existing Device Setup File in order to convert it to the new format CHANGE Usage of the low Fragmentation Heap The X Tools Client now uses the low fragmentation heap for all memory allocations In case of applications with frequent allocation and freeing of memory e g opening and closing of editors the low fragmentation heap allows to run the application longer without running into low memory conditions because of memory fragmenta tion CHANGE Removing of the Info Item from Trees The Info item has been removed from all trees of the X Tools Client The information which was provided below the Info item so far is shown directly at the level of the former Info item now CHANGE Improved Restart of Configuration Files after a Change of the System Time In c
87. ation of Configuration File States within Trees In case a directory or any of its sub directories contains a started or a suspended Configuration File the icon of the directory within the explorer tree of X Tools shows an according icon This indication allows to browse to the currently started suspended Configuration File very fast FEATURE Export of Data of Type 2 dimensional Vector to CSV Files Also data of type 2 dimensional vector can be exported to CSV files now FEATURE Overview Dialog for Analyzing Functions and User Function Via the Overview context menu item of each Analyzing Function and User Function from the ANS Explorer the Analyzing Function Overview and User Function Overview dialogs can be called now These dialogs are non modal and can stay open while the rest of X Tools can be used normally They provide detailed information about an Analyzing Function User Function and about all of its arguments thus they are a kind of help infor mation during the creation of Analyzing Models and Analyzing Scripts FEATURE Automatic temporary Update of Analyzing Models In case an Analyzing Model is started which contains outdated interface definitions the Analyzing Engine at tempts to update the Analyzing Model automatically and temporarily When the update succeeds the Analyzing Model is started and an according log entry is created FEATURE Detection of Analyzing Functions from third Parties I
88. automatic scaling within the MTC yt T001 The automatic scaling of the y axis of the MTC yt T001 could fail in case the difference between the minimal and maximal to be displayed axes values was smaller than the minimal allowed scaling interval BUGFIX Storage Profiles which store offline Data may not stop In case a Storage Profile was configured to store offline data there was a possibility that the Storage Profile did not stop after it has finished to process all offline data In this situation the Storage Profile stayed in status run ning or triggering forever BUGFIX Unclean Termination of Socket Connections In case the Interface Profile for the socket interface was stopped while the socket devices were streaming data the connection could be terminated without a prior notification to the devices Therefore the devices may have continued to stream data until they ran into their own timeout for the connection BUGFIX Wrong Timezone within exported csv Files In case the timestamp format for the export to csv was configured to Date Time ns Local Time the timestamps of all values were created in local time but the two timestamps within the header row were still in GMT BUGFIX Possibly wrong Stop Time of offline Data Files In case a Storage Profile was configured to store offline data from the MDS Explorer to offline data files with a stop trigger of type by Timer or by Date and Time the stop time of t
89. cally open the Monitoring Views during its startup which were opened during its last shutdown FEATURE Configurable Email Subject The new global option Email Subject can be used in order to configure which subject shall be used by X Tools when it sends a notification via email In case an Analyzing Function is being used for the sending of emails a different email subject can be configured there FEATURE Improved dropping of Analyzing Functions into the AME Standard T001 In case one or multiple Analyzing Functions are being dragged into the AME Standard T001 a rectangle shows the exact position to which the currently dragged function s would be dropped In case the dropping is possible the rectangle is filled with green color when the dropping is not possible e g because of too little available space the rectangle is filled with red color The mouse cursor icon also shows whether dropping is possible at the current position or not The same method is being used also in case Analyzing Functions are being moved within the Analyzing Model Editor FEATURE Safe overwriting of all Configuration Files Whenever a new version of a Configuration File is being written to disk a safe mechanism is being used so that it is guaranteed that either the previous or the new file will be valid even in case a severe error g power down occurs in the moment of the safe operation FEATURE Context Menu of the Pause and Continue Butto
90. case the specified alarm bands pointed to frequencies outside of the frequency range of the to be monitored spectrum wrong log entries about the violation of amplitudes outside the frequency range of the to be monitored spectrum could be created BUGFIX Wrong Log Entry about a wrong minimum or maximum Time Value In case a wrong minimum or maximum time value was passed to an Analyzing Model the created log entry did not point out this error Instead another derived error was output to the system log BUGFIX Passing of the Time Interval to an Analyzing Model It was not possible to pass a time interval value with a format different to s to an Analyzing Model because the Analyzing Model always has interpreted the passed time interval value in seconds BUGFIX Passing of None use Start Time of the Analyzing Model to an Analyzing Model It was not possible to pass a minimum time format of None use Start Time of the Analyzing Model to an Ana lyzing Model BUGFIX Wrong remembering of expanded and collapsed Branches within the MDX Explorer The MDS Explorer did not remember the expand collapse state of its contained items properly As a result most data was displayed collapsed when it was re added to the MDS Explorer and the Global Settings gsf xtc file could become very huge English Release 2014 11 65 81 CMS X Tools Change Log CMS BUGFIX Possible Hang of the X Tools Client after searching within the MDS Explo
91. ccess to Fast Analysis Scripts for Users different to Administrator In case the X Tools Client was connected to the X Tools Server with a user different to Administrator it was not possible to run any Fast Analysis Script via the MDX BUGFIX Wrong Path Information for Analyzing Models and Analyzing Scripts The internal mechanism which can be used by Analyzing Functions in order to determine the path of their par ent Analyzing Model Analyzing Script contained an error so that the path contained the Analyzing Models di rectory even in case this information was requested by an Analyzing Script Analyzing Functions like RemCnt and ShowPath were effected by this error BUGFIX Possibly wrong decoding within the Analyzing Function OutputTCP This Analyzing Function could handle the passed 1 dimensional buffer in a wrong way As a result it could transmit wrong values via the TCP connection and the receiver could see only 0 values BUGFIX Missing Visualization after a reconnect of the X Tools Server In case the connection to an X Tools Server got broken and re established while a Monitoring View was visual izing data from this X Tools Server the Monitoring View did not restore its status properly after the reconnect As a result the values of the contained data were not displayed any more BUGFIX Possibly wrong Order within the User Function Overview Dialog There was a possibility to end up with a User Function w
92. ch sec ond BUGFIX Possible Data loss during the Communication with UDP Devices In case multiple UDP devices e g ION SIMATIC S7 PN ION SIMOTION T001 were streaming data there was a possibility to loose single data packets BUGFIX Possible Crash when appending of offline Data There was a possibility to end up in a crash in case some offline data has been appended to already present offline data of matching name but different data type 2 3 X Tools V 03 02 gt X Tools V 03 03 The following changes have been introduced in X Tools V 03 03 FEATURE Cable Break Detection for the IFN VIB A The IFN VIB A now is able to send a notification to the X Tools Server whenever it detects a possible change of the status OK cable break or short circuit of any sensor cable Within the Device Profile Editor for the IFN VIB A it can be configured now how the X Tools Server shall react to such a possible change Therefore the new parameter Automatic Update of the Channel Status has been added to the DPE IFN VIB ACC FEATURE Support for Windows Server 2003 as Operating System In addition to Windows XP now also Windows Server 2003 is supported as operating system FEATURE New Monitoring Chart for y f x Visualizations The new MTC yx T001 allows to visualize data in form of y f x FEATURE User Function Files User Function Files can be created like Analyzing Models After a User Function File has been saved it appears Englis
93. ck all of the events of its input data at each call of the Analyzing Function Now only the new events are checked when the Analyzing Function is called BUGFIX Action based Analyzing Models Analyzing Scripts are unable to work with different Time Do mains In case an Analyzing Model Analyzing Script with a calculation mode of Action based was configured to take an offline data with absolute timestamps as input and to output an offline data with relative timestamps or vice versa the Analyzing Model Analyzing Script suspended directly at its start BUGFIX It was not possible to change the Order Window Tabs In case the window mode was Tabbed it was not able to change the order of the present tabs BUGFIX Improved Detection of IEEE1394 Devices In some cases it was possible that X Tools did not recognize all of the IEEE 1394 devices which were present within the Device Manager of Windows BUGFIX Passing of Data Identifiers to the Analyzing Function OutSclir The Analyzing Function OutSclr did not accept a data identifier like SomeData as input argument value BUGFIX Unwanted Change of the Position of the Measurement Cursors within the MTC yt T001 The position of the present measurement cursors could be changed at wrong moments for example after a zooming operation or after the MDS Explorer has been shown hidden In such situations also the displayed minimal maximal and average values within the Measurement Cursor
94. cted this er ror As a result it could show that it was running although it did not create any files or directories BUGFIX Wrong resuming through the Analyzing Function FFT In case the Analyzing Function FFT detected a wrong number of values within its input buffer it suspended and resumed its parent Analyzing Model Analyzing Script all the time As it is unlikely that the number of values within the input buffer changes the Analyzing Function suspends the parent Analyzing Model Analyzing Script now and does not attempt to resume BUGFIX Bad Log Entry from an Analyzing Model which received an invalid Data Name Prefix In case an Analyzing Model has been started with an invalid data name prefix for input and or output data the log entry complained about the resulting data name instead of explaining that the data name prefix is invalid BUGFIX Wrong Interpretation of textual Time Interval Formats through Analyzing Models In case the to be used time interval format was passed to an Analyzing Model as parameter the Analyzing Model could interpret the provided time interval format wrongly BUGFIX Disappearing Short Name within the Title Bar of Dialogs In case the title bar of a dialog was configured to show the short name this setting could be forgotton after op erations like saving of the edited file In this situation the long name of the dialog was displayed again although the check mark within the context menu still was in front
95. d Offline Data context menu item is chosen from the MDS Explorer or STS Explorer and there is an ODL Standard T001 opened already the already present ODL Standard T001 is brought to the front and no new ODL Standard T001 is opened CHANGE Default Time Base within the Monitoring View Parameters Table The default time base of the Monitoring View Parameters table of the MVE Standard T001 has been changed to Use the local Time of the Offline Data CHANGE New X Tools Server Status Dialog The X Tools Server Status dialog of the X Tools Tray has been changed so that it displays the available in formation in a more structured way now CHANGE New Position of the Provided Parameters Table within the AME Standard T001 The Provided Parameters table within the AME Standard T001 has been moved upwards This was done because several other editors start to provide a Provided Parameters table and all of them place this table at the same position now CHANGE New PathType Values for the Analyzing Function ShowPath The meaning of the already known values for the PathType input argument has changed so that Absolute English Release 2014 11 70 81 CMS X Tools Change Log CMS Path and Symbolic Path return only the path without the file name now In case also the file name is re quired the new values Absolute Path File Name and Symbolic Path File Name can be used
96. d clients already the X Tools Client outputs an according log entry now In addition in case the same English Release 2014 11 37 81 CMS X Tools Change Log CMS reason is present as description of the error of successive connection attempts an according log entry is added only for the first detected error CHANGE New default Colors for all Cursor Lines New default colors have been configured for the cursor lines of all Monitoring Charts CHANGE Additional default Location for offline Data In addition to the default location for offline data in the binary format of X Tools sdf xts another location for offline data in CSV format csv is created by default now CHANGE New export Location for CSV csv and DAT dat Files From now on the export of data files of format CSV csv or DAT dat must be performed into an offline data location of type CSV csv CHANGE Improved handling of corrupted offline Data Files The ODL Standard T001 now displays also offline data files which were recognized to be corrupted CHANGE Improved Log Entries about the Configuration of the X Tools Service During its termination the X Tools Server always updates the configuration of the X Tools Service according to the current settings from the global options From now on according log entries appear only in case any con figuration of the X Tools Service really had to be changed CHANGE Behavior of Analyzing Functions after a C
97. data names and other parameters as parameters of the Device Profile Such a Device Profile with parameters can be started via the Analyzing Function StartEx in order to pass the desired parameters to it or it can be used by the Analyzing Function CreateCFEx in order to prepare a new Device Profile with proper default parameters FEATURE Parameters for Monitoring Views The MVE Standard T001 now allows to configure data names and other parameters as parameters of the Moni toring View Such a Monitoring View with parameters can be started via the Analyzing Function StartEx in order to pass the desired parameters to it or it can be used by the Analyzing Function CreateCFEx in order to prepare a new Monitoring View with proper default parameters FEATURE Parameters for Storage Profiles The SPE Binary T001 now allows to configure data names and other parameters as parameters of the Storage Profile Such a Storage Profile with parameters can be started via the Analyzing Function StartEx in order to pass the desired parameters to it or it can be used by the Analyzing Function CreateCFEx in order to prepare a new Storage Profile with proper default parameters FEATURE Shifting of the Toolbar of Monitoring Charts In case the currently available width of a Monitoring Chart is so small that not all of the to be displayed toolbar buttons fit into the available width the toolbar can be shifted left and right via the right mouse button FEATURE
98. den In case the y Axes Area was hidden within the MTC yt T001 and MTC yn T001 it was not possible any more to shift the displayed curves into the y direction BUGFIX Possible Crash in case the Skin File has been corrupted The X Tools Client could crash during the loading of the skin file in case the skin file was corrupted BUGFIX Monitoring Charts were opened always at the Bottom In case data has been dropped into a Monitoring View Editor and a new Monitoring Chart had to be opened because of the drop the new Monitoring Chart was placed always at the bottom of the Monitoring View Instead the Monitoring Chart is opened at the position where the mouse cursor has been released now which can be left right at the bottom or at the top of an already existing Monitoring Chart BUGFIX Unwanted Change of the Column Width within the Advanced Load Store Export Dialogs Within the Advanced Append Advanced Overwrite Advanced Store and Advanced Export dialogs the width of the columns could change whenever a new value was entered into any of the editable cells BUGFIX Possible Crash because of the deleting of a Location There was a possibility that X Tools could crash when the root directory of one of its locations was deleted from outside Typically the root directories of locations of X Tools can not be deleted from outside because they are locked BUGFIX Disconnects because of Network Tunnels In case the connection between X Tools Client
99. der to start a Configuration File which stops immediately Start wait ed endlessly for the start or stopping of this Configuration File BUGFIX The ANF Start handles corrupted Configuration Files wrongly In case the ANF Start is being used in order to start a Configuration File which is corrupted Start did not return immediately Instead it waited for the timeout time before it returned BUGFIX The ANF Start handles suspending Configuration Files wrongly In case the ANF Start is being used in order to start a Configuration File which suspends immediately Start did not return even in case DoNotWait was specified as parameter Start also did not return after the timeout in case Wait was specified as parameter BUGFIX Wrong Visualization of moderate and thick Grids within the MTC ynm T001 In case the MTC ynm T001 displayed two data where one of them was configured to Surface and the other one to Grid with moderate or thick lines the position of the data which was displayed as grid was wrong BUGFIX High CPU Usage during the Stopping of Configuration Files through the ANF Stop In case of single core computers a high CPU usage could be observed during the stopping of Configuration Files out of Sequence control scripts which used the ANF Stop BUGFIX Possible Crash in case of fast start and stop of an Interface Profile Fast start and stop of an Interface Profile could end up in acrash
100. ding of some data there is not saving confirmation being displayed to the user any more CHANGE Improved Behavior of the Previous Entries and Next Entries Buttons of the System Log Viewer Now the Previous Entries button is enabled whenever there is at least one entry available before the currently displayed oldest entry In addition the Next Entries button is enabled whenever there is at least one entry available after the currently displayed newest entry CHANGE Basic Protection of started Configuration Files In case a Configuration File is started the X Tools Client does not allow to delete rename or move its file within the explorer tree CHANGE Default rendering Mode The default rendering mode within Monitoring Charts has been changed from Fast to Minimal and Maximal Value CHANGE Behavior of paused Device Profiles In case a Device Profile is paused it now continues to perform all operations except adding of values into its ring buffers Thus log entries about errors within the received data now also can be created for paused Device Profiles CHANGE Start Index of the Analyzing Function GetBffrM The index of the Analyzing Function GetBffrM now starts with O instead of 1 CHANGE Integral for sequential Analyzing Scripts The Analyzing Function Integral now also can be used in Analyzing Scripts which are configured to an Oper ating Mode of Sequential BUGFIX Suspe
101. ditional Analyzing Function IIRLowPassFilterButterworth The additional Analyzing Function IIRLowPassFilterButterworth calculates an up to 20 th order IIR Butterworth filter FEATURE Additional Analyzing Function IIRHighPassFilterButterworth The additional Analyzing Function IIRHighPassFilterButterworth calculates an up to 20 th order IIR Butterworth filter FEATURE Additional Analyzing Function IIRBandStopFilterButterworth The additional Analyzing Function IIRBandStopFilterButterworth calculates an up to 10 th order IIR Butter worth filter FEATURE Additional Analyzing Function AverageSpectrum The additional Analyzing Function AverageSpectrum calculates an average spectrum FEATURE IEEE1394 Gap Count Monitoring X Tools checks the gap count of all present IEEE1394 devices now and re initializes the IEEE1394 bus in case it detects that not all of the present IEEE1394 devices share the same gap count Inconsistent gap counts at the IEEE1394 bus can cause data loss and interrupted data transmission from IEEE1394 devices in combination with IEEE1394b host adapters FEATURE Configuration of the Target Name of Configuration Files via Drag amp Drop The Target Name of each configuration file which is opened within its editor now can be switched between the local file system of the client and any of the currently connected servers by simply dragging of the Main item for the local file system of the client or of any S
102. dows The context menus of X Tools Client windows provide additional possibilities for automatic arrange Tile hori zontally Tile vertically and Tile automatically FEATURE Hiding of Configuration Areas Via context menu it is possible to show or hide the Configuration Area of the following editors MVE Standard T001 AME Standard T001 and ASE Standard T001 FEATURE Support of SIPLUS CMS4000 ION SIMATIC S7 PN Support of the new software I O Node SIPLUS CMS4000 ION SIMATIC S7 PN FEATURE Simultaneous changing of the Storage Mode within Storage Profiles Within the SPE Binary T001 it is possible now to change the Storage Mode of multiple Data simultaneously FEATURE Simultaneous changing of the Loading Mode within Loading Profiles Within the LPE Binary T001 it is possible now to change the Loading Mode of multiple Data simultaneously FEATURE Apply to selected and Apply to all for all Record Storage Loading Mode Columns The Apply to selected and Apply to all context menu entries now are available for the Rec ord Storage Loading Mode columns of all Device Profile Editors Storage Profile Editors and Loading Profile Editors FEATURE Adding of Device Versions to the System Log Whenever a device is being attached to the X Tools Server the version of the device is added to the system log FEATURE lt F5 gt can be used in order to refresh the Contents of Trees In case a tree ha
103. e Profile or an Analyzing Script has been re named the icon of the affected Configuration File was not updated accordingly English Release 2014 11 23 81 CMS X Tools Change Log CMS BUGFIX Unwanted moving of Window Tabs There was a possibility that the window manager behaved as if the left mouse button would be pressed above the tabs of tabbed windows even though the left mouse button was not pressed any more As a result the win dow tabs could be moved without the left mouse button being pressed BUGFIX Improper Conversion from Strings to Integer Values within the Analyzing System A string like 1234abc was converted to an integer value of 1234 No in case a string like 1234abc is being provided as input of an argument of type integer an error message is being created BUGFIX Unwanted Conversion of String Values for Input Arguments which do not support Strings Input values of type string where converted to a value even in case the input argument did not list strings as supported data types Especially in combination with Boolean input arguments this could lead to undetermined results BUGFIX Improved Handling of Characters which are not allowed within the Names of Data A string like 1234abc was converted to an integer value of 1234 No in case a string like 1234abc is being provided as input of an argument of type integer an error message is being created BUGFIX Wrong Log Entries about T
104. e Windows kernel This memory leak was able to consume all of the available non paged memory in which case most system functions stopped to work In worst case also a blue screen could occur BUGFIX Visualization of binary Bars In case binary bars with a value of 1 were visualized within the MTC yt T001 the filling of the bar was not being done after the last known timestamp from the data In case of data which was recorded with a record mode of Changes only the filling was always missing because of this effect BUGFIX Missing suspend of Storage Profiles in case of an unavailable Storage Location In case the storage location of a Storage Profile was not present the Storage Profile could stay in status start ed instead of suspending This wrong behavior occurred in case the size of the ring buffer was very low when it contained less than 10 seconds of data English Release 2014 11 30 81 CMS X Tools Change Log CMS BUGFIX Data Supervision Entries in case of slow Sample Rates of the IFN VIB ACC In case one channel of an IFN VIB ACC was configured to a sample rate of 14 Hz the data supervision could have created a log entry even though the data from the other channels was available constantly BUGFIX Wrong loading of Offline Data Files which contain only a single Probe before their Start Time In case of offline data files which contain only one probe and when this probe is before the start time of the of fline data
105. e data files were appended one after the other and each of them contained exactly one probe one pair of timestamp value the appending could fail silently and no additional values were added to the existing offline data BUGFIX Applying of the Security Updates for OpenSSL The used components of OpenSSL have been updated to V 1 0 1h This hotfix includes updates for the follow ing third party DLLs libeay32 dll libxml2 dll and uastack dll BUGFIX Missing Check Mark within the Context Menu of the MTC yn T001 In case the sliders were hidden none of the sub items of the Show Sliders context menu had a check mark Now the check mark is displayed properly in front of the No sub item BUGFIX Missing support for Decimal32 through the Analyzing Function OutSpm The Analyzing Function OutSpm output its data with a precision of Decimal64 always even in case another Precision was configured BUGFIX Missing support for Decimal32 through the Analyzing Function InSpm The Analyzing Function InSpm was not able to handle input data with a precision different to Decimal64 BUGFIX Unwanted re appearing of the Configuration Area In case the Configuration Area within the AME Standard T001 UFE Standard T001 and or MVE Standard T001 was hidden it could re appear automatically in different situations even though it still was configured to be hidden BUGFIX Suspend through the Analyzing Function GetVFrmSD in Combination with O
106. e data transmission In case such a notification is being received it is added to the System Log of the X Tools Server now FEATURE Additional Format for the Data Type Spectrum The data type Spectrum is able to handle order spectrums from now on FEATURE Visualization of the Unit at the x Axis of the MTC yn T001 In case a frequency spectrum is being visualized the unit is displayed as Hz now Contrary in case an order spectrum is being visualized the unit is displayed as 1 now FEATURE Detection of invalid PROFIBUS DP Packets by the ION PROFIBUS DP Spy T001 In case an invalid PROFIBUS DP packet is being delivered by the ION PROFIBUS DP Spy T001 the packet is ignored and its data is not added to the internal buffers of X Tools A PROFIBUS DP packet is identified as inva lid in case its start delimiters do not match its length fields do not match its end delimiter is wrong or its frame check sum is wrong FEATURE Advanced support for the lt Open Context Menu gt Key from the Keyboard The lt Open Context Menu gt key from the keyboard can be used within all trees now in order to open the context menu of the currently selected tree item FEATURE Double Click onto an Input Argument within the AME Standard T001 starts editing A double click onto an input argument of an Analyzing Function within the AME Standard T001 now behaves like the lt F2 gt key for the currently selected input argument and starts to edit the valu
107. e highest possible output was maximum 1 English Release 2014 11 38 81 CMS X Tools Change Log CMS BUGFIX Possible Crash when ANE dll is missing In case the ANE dll is missing and a change of the system time is detected there was a possibility for the X Tools Server to end up in a crash BUGFIX Loading of big offline Data Files It was not possible to load big offline data files even with a loading mode like Interval only because the calcula tion of the estimated memory usage was wrong BUGFIX Improved Memory Allocation within the Analyzing Function Delay In previous versions this Analyzing Function was able to re allocate its internal memory once each time slice which could cause heavy usage of kernel time BUGFIX Missing update of changed UlKs The X Tools Server did not recognize a changed UIK in case the UIK of one device was changed between its disconnect and the following connect BUGFIX Failed open of User Function Files with conflicted Names Out of the AME Standard T001 t was not possible to open a User Function via the Open context menu item in case the name of the User Function was equal to the name of an existing Analyzing Function BUGFIX Possible Memory Leak when opening and closing of the Monitoring System A memory leak could occur in case the Monitoring System was opened and closed several times in a row BUGFIX Missing apply of Standard Chart Options The Monitoring Charts MTC yn T
108. e of Lines was configured the resampling within InOrdRsmpl could produce inaccurate results The difference between the input data and the output data of InOrdRsmpl could be seen clearly within the Monitoring System in this case BUGFIX Possibly missing Files after a Data Snapshot In case a data snapshot from the Monitoring System had to store multiple files of identical name at the same time it could happen that only the first of these files was created Now a unique file name is granted for every offline data file which is created by the data snapshot BUGFIX Format of Log Entries from Triggers about offline Data with Relative Timestamps The format of the relative times within the log entries about start and stop triggers was wrong the determined timestamp was formatted as absolute time Now the correct format is used in case the timestamp format shall be relative English Release 2014 11 53 81 CMS X Tools Change Log CMS BUGFIX Incomplete Initializations after opening of a Storage Profile In case a Storage Profile was opened within a SPE Binary T001 already and another Storage Profile was dropped into the already present SPE Binary T001 some settings from the first Storage Profile could remain present For example in case the first Storage Profile had a Trigger Data Type of Numerical this value stayed Numerical even in case the Trigger Data Type of the second Storage Profile was Boolean
109. e of the input argument FEATURE Additional Analyzing Function InputAntiAliasingFilter The additional Analyzing Function InputAntiAliasingFilter reads anti aliasing filtered simple online or offline data from the system FEATURE Additional Analyzing Function RainflowCounting The additional Analyzing Function RainflowCounting calculates the rainflow counting algorithm FEATURE Additional Analyzing Function TimeAtLevelCounter The additional Analyzing Function TimeAtLevelCounter calculates the time at level counting algorithm FEATURE Additional Analyzing Function Exit The additional Analyzing Function Exit is able to stop execution of current time sliced program on current heartbeat FEATURE Additional Analyzing Function IsDataPresent The additional Analyzing Function IsDataPresent points out whether the specified online or offline data is cur rently present FEATURE Additional Analyzing Function RemoveAllDataFrom The additional Analyzing Function RemoveAllDataFrom removes all of the offline data which has been created by the specified Analyzing Model or Analyzing Script FEATURE Additional Analyzing Function Start The additional Analyzing Function Start starts the execution of the specified configuration file FEATURE Additional Analyzing Function Stop The additional Analyzing Function Stop stops the execution of the specified configuration file FEATURE Additional Analyzing Function Wa
110. e specified envelopes FEATURE Additional Analyzing Function ConvB1DToTS The new Analyzing Function ConvB1DToTS can be used in order to convert the values of a 1 dimensional buffer into a time series FEATURE Additional Analyzing Function SpmAdd The new Analyzing Function SpmAdd can be used in order to increase or decrease all amplitudes of the provided input spectrum FEATURE Additional Analyzing Function MonSpmEnv The new Analyzing Function MonSpmEnv can be used in order to monitor whether the values of the current input spectrum are within the specified envelopes FEATURE Additional Analyzing Function ConvPToV2D The new Analyzing Function ConvPToV2D can be used in order to convert polar coordinates into a 2 dimensional vector FEATURE Additional Analyzing Function ConvV2DToP The new Analyzing Function ConvV2DToP can be used in order to convert a 2 dimensional vector into polar coordinates FEATURE Additional Analyzing Function InV2D The new Analyzing Function InV2D can be used in order to read a 2 dimensional vector from the system so that it can be used within the Analyzing Model Analyzing Script FEATURE Additional Analyzing Function OutV2D The new Analyzing Function OutV2D can be used in order to write a 2 dimensional vector which has been created within the Analyzing Model Analyzing Script to the system English Release 2014 11 42 81 CMS X Tools Change Log CMS FEATURE Additio
111. e the new MTC yx T001 was not able to display a curve unless its y axis data was dropped into the MTC yx T001 again BUGFIX Possible Crash when creating a new t Axis within the MTC yt T001 In case the Create new t Axis context menu item from the legend of a MTC yt T001 was called while the visu alization was paused a crash could occur BUGFIX Possible Crash within the X Tools Service in case the Computer shuts down There was a race condition which could cause the X Tools Service to crash when it should terminate during the shut down of the computer BUGFIX Possible Crash within the X Tools Client There was a possibility to end up in a crash when the X Tools Server became disconnected exactly in the mo ment when a Configuration File was dropped in order to start its editing BUGFIX Inaccurate Log Entries for the automatic Restart of Analyzing Models Analyzing Scripts The log entries during the restart of Analyzing Models Analyzing Scripts after a change of the system time took place were not complete The last log entry for an Analyzing Model Analyzing Script pointed out that it was stopped which was not true the Analyzing Model Analyzing Script was restarted properly BUGFIX Unwanted expanding of all Items within the MDS Explorer In some situations pressing of lt F5 gt within the MDS Explorer did not only update all of the displayed items but it also expanded all of them BUGFIX Improved Log Entries in case of invalid
112. e was above a place which accepts the dragged data or not BUGFIX Wrong rendering of too big Values within Monitoring Charts In case a to be displayed value was out of range the Monitoring Charts could display wrong lines all over the screen BUGFIX The Cutoff Frequencies of all Filter Analyzing Functions were interpreted as Integers internal ly All filter Analyzing Functions interpreted the provided cutoff frequencies as integers internally The following Analyzing Functions were affected BP BS HP LP IRBPBT IIRBSBT IIRHPBT IIRLPBT IIRBPCH1 IIRBSCH1 ITRHPCH1 IIRLPCH1 IRBPCH2 IIRBSCH2 IRHPCH2 and IIRLPCH2 English Release 2014 11 34 81 CMS X Tools Change Log CMS BUGFIX Missing clean up in case of failed loading of offline Data In case the loading of offline data had to be cancelled because of not enough memory there was a possibility that the already loaded parts of the data were not freed from the memory properly BUGFIX Missing clean up during the stopping of Storage Profiles During the manual stop of Storage Profiles there was a possibility that not all of the allocated memory was freed In case of frequent start and stop operations a significant amount of memory could be used BUGFIX Wrong Hit Check for the Tool Tips within the AME Standard T001 After an Analyzing Function was expanded within the AME Standard T001 the hit test for the tool tip was not updated Therefore t
113. ed in order to be able to access and use the advanced Analyzing Functions CHANGE Improved Handling of the Address Book of ION SIMATIC TDC T001 Devices The address book is being saved only in case it is mandatory now and it can be saved to and opened from any location e g also to from the local client In addition downloading of the address book does not block the user interface of the X Tools Client any more CHANGE Advanced csv Export The format of exported csv files has been improved so that it is more common among the different data formats simple data types 1 dimensional buffers 2 dimensional buffers and spectrums and descriptive now CHANGE Further Improvements for more Commonness with Explorer Trees Not all operations which can be performed on explorer trees were handled absolutely identical by all of the pre sent explorer trees For example there were differences during the copy cut paste of tree items CHANGE Disabling of different Data Formats for Bit Arrays Within Device Profile Editors the data format of bit arrays can not be switched between Big Endian MSB first and Little Endian LSB first any more English Release 2014 11 15 81 CMS X Tools Change Log CMS CHANGE Improved direct Editing within the Analyzing Model Editor In case the value of an argument is being edited directly within the Analyzing Model Editor via the lt F2 gt key lt Cursor left gt and lt Cursor right gt do not end the editing
114. efore the system time has reached the timestamp of the offline data which was farthest in future BUGFIX Possible Corruption of old User Functions User Functions which were created by V 03 03 could become corrupted when they were opened with newer versions in case their internal return value state was inconsistent already BUGFIX Improper Handling of the Update Interval through the Analyzing Function H2D In case the configured update interval of H2D e g 100 ms was an integer multiple of the current cycle time e g 10 ms H2D has output one new value each update interval cycle time interval in this example it has output one new histogram each 110 ms instead of each 100 ms BUGFIX Missing Provided Parameters Table within Reports out of the AME Standard T001 In case a report was created out of an AME Standard T001 the report did not contain any information about the Provided Parameter table and its contents BUGFIX Possible Crash within the AME Standard T001 because of outdated Selections In case the context menu was called within the AME Standard T001 the previous selection of Functions and or input output arguments was not updated properly and the access to a wrong index could cause a crash BUGFIX Possible Crash because of a too early Access to Data A certain timing could lead to a situation where the Monitoring System tried to access a data which was not available yet and the X Tools Server could crash
115. end up in a crash BUGFIX Wrong handling of the IEEE1394 Bus Reset Count 0 In case the IEEE1394 bus reset count wrapped back from 255 to 0 the X Tools Server did not process this bus reset As a result the enumeration of present devices did not take place and the X Tools Server did not connect to any IEEE1394 devices until the next IEEE1394 bus reset took place BUGFIX Possibility for missing Clean Up after an IEEE1394 Bus Reset After an IEEE1394 bus reset took place there was a possibility that the necessary clean up of an address range failed In such a case it could happen that the following communications to IEEE1394 devices failed BUGFIX Possible Hang during the start resume of Device Profiles A failed start or resume of a Device Profile could cause a permanent hang of the X Tools Server because the necessary clean up was not being performed in some cases BUGFIX Permanently suspended Device Profiles In case of massive amounts of device attaches and detaches within short time there was a possibility that a Device Profile became suspended and never was resumed thus it stayed suspended forever BUGFIX Disappearing Stop Event Immediately The stop event Immediately was not being shown within the SPE Binary T001 in some cases BUGFIX Possible Memory Leak within the nonpaged Kernel Memory In case of huge amounts of IEEE1394 bus resets there was a possibility to end up with a memory leak within the nonpaged memory of th
116. ent offline data was exported BUGFIX Forwarding of Commands to wrong Locations In case the symbolic name of one Configuration File location e g Location was equal to the beginning of the symbolic name of another location e g Location X calling of commands like Start or Stop at directories of the first location could issue these commands also at directories of the second location BUGFIX Repeated renaming of Configurations Files could fail In case multiple Configuration Files of identical name were created and renamed repeatedly the rename opera tion could become blocked after some iterations BUGFIX Values with a Timestamp of 0 were not stored by the Storage System In case an offline data with relative timestamps contained a timestamp of 0 this probe was ignored by the Stor age System and was not added to the current offline data file BUGFIX InOrdRsmpl could cause a Crash In case the input data of the Analyzing Function InOrdRsmpl had a data type different to Decimal64 the func tion could end up in a crash BUGFIX InOrdRsmpl may not be able to initialize properly In case the input data for InOrdRsmpl was not present at the moment of the start of the Analyzing Mod el Analyzing Script InOrdRsmpl had a chance to initialize in a wrong way As a result it may not have pro duced any output afterwards BUGFIX The Output of InOrdRsmpl may be too inaccurate In case an interpolation mod
117. er lt F5 gt In some cases updating of the contents of an explorer tree via lt F5 gt also has changed the expand collapse state of items BUGFIX Unwanted append of offline Data from different Time Domains It was possible to append offline data with identical name from different time domains Undefined time intervals which were covered through the resulting offline data BUGFIX Impossible pausing within Monitoring Charts It was impossible to pause the visualization within Monitoring Charts in case one of the data from the Monitoring Chart was currently not available BUGFIX Unwanted continue after pausing within Monitoring Charts In case a Monitoring Chart contained data with only a few values the Monitoring Chart could automatically con tinue the visualization of online data a few seconds after it had been paused BUGFIX Wrong automatic Update of User Functions In case a User Function contained another User Function whose interfaces have changed the automatic update of the parent User Function could fail and result in an invalid internal status of the parent User Function BUGFIX Too long connecting to ION SIMATIC TDC T001 Devices In case the first connecting attempt to an ION SIMATIC TDC T001 device failed also the following connection attempts had a bigger chance to fail As a result it could take up to minutes until the connection could be estab lished successfully BUGFIX Possible Crash within the MVE Standard T001 I
118. er spectrum violates the specified frequency or order spectrum envelope FEATURE Additional Analyzing Function MonAmpl The new Analyzing Function MonAmpl can be used in order to monitor whether the specified frequency or order spectrum violates the specified alarm band This Analyzing Function also monitors the amplitude trend for the specified alarm band FEATURE Additional Analyzing Function MonAmpls The new Analyzing Function MonAmpls can be used in order to monitor all amplitude trends for the specified frequency or order spectrum and frequency or order spectrum envelope FEATURE Additional Analyzing Function InSpmEnv The new Analyzing Function InSpmEnv can be used in order to read frequency or order spectrum envelopes from the system FEATURE Additional Analyzing Function OutSpmEnv The new Analyzing Function OutSpmEnv can be used in order to write frequency or order spectrum enve lopes to the system FEATURE Additional Analyzing Function GetStrFrmSD The additional Analyzing Function GetStrFrmSD can be used in order to extract a single string out of a time series of data FEATURE Additional Analyzing Function GetLctnPath The additional Analyzing Function GetLctnPath can be used in order to determine the absolute path to an existing location FEATURE Additional Analyzing Function TLC2D The new Analyzing Function TLC2D can be used in order to calculate the time at level counting for
119. erver item for the according server from the explorer tree of the current system FEATURE Additional Column 1 T2 T1 for the Cursor Table of the MTC yt T001 The cursor table of the Monitoring Chart for y f t visualizations has received an additional column which dis plays the value of 1 T2 T1 which matches the frequency of the time period between the two cursors CHANGE Loading of Offline Data The former Storage Data Editor has been renamed to Offline Data Loader Loading of offline data via the Offline Data Loader now can be started directly via the context menus of the MDX and of the STX CHANGE Stop Time of offline Data Files In case of continuous storage the stop time of an offline data file now matches the start time of its following offline data file In previous versions the stop time of an offline data file was 1ns before the start time of its fol lowing offline data file English Release 2014 11 6 81 CMS X Tools Change Log CMS CHANGE Check of the Trigger Data Types When a Storage Profile is being started and it is configured to trigger by some data the data type of the input data for the trigger either binary or numerical now must match the data type which is configured within the Storage Profile In case the configured and the current data type do not match the Storage Profile is being sus pended CHANGE Suspending in Case of missing Trigger Data In case the input data
120. es The speed of the loading of offline data files has been improved CHANGE Additional Checks during the start of Device Profiles Previously the start of a Device Profile was considered to be successful after the target device has acknowl edged the start properly Now at least one valid data packet must be received additionally In case there is no valid data packet after the start of the Device Profile the Device Profile is being suspended CHANGE Changed Check of the Base Levels within the Analyzing Function MonAlrmSpm The Analyzing Function MonAlrmSpm now allows its BaseL1 to be greater than or equal to BaseL0 In addi tion BaseL2 can be greater than or equal to BaseL1 CHANGE Increased maximal Size for the Transmissions between X Tools Client and X Tools Server The maximal size of transmission between the X Tools Client and the X Tools Server has been increased The previous limit could cause transmission errors especially in case of transmissions of large encrypted User Function Files CHANGE New Format of exported csv Files The format of exported csv format has been optimized for less disk usage and more human readability Each exported csv file now also provides more meta information about its contained data CHANGE Improved Log Entry by the X Tools Client when it can t connect to the X Tools Server In case the X Tools Client can t connect to the X Tools Server because the server has the maximal amount of connecte
121. estamps and values of offline data with relative timestamps even in case the t axis was configured to show offline data with absolute timestamps As a result the displayed timestamps were wrong BUGFIX Missing Visualization of Values from Data with only 1 Probe In case some data with only one existing probe was put into the MTC yt T001 there was a chance that no value of this data was displayed by the MTC yt T001 BUGFIX Wrong initial Time Interval within the MTC yx T001 In case a MTC yt T001 was converted into a MTC yx T001 the slider of the MTC yx T001 could show a time interval e g 15 seconds which was different to the time interval that was used for the visualization of the curve e g 10 seconds BUGFIX Unused Postfix within the Legend of Monitoring Charts In case of Monitoring Views which have been created by older versions of X Tools there could be a kind of postfix displayed within the legend of each Monitoring Chart English Release 2014 11 78 81 CMS X Tools Change Log CMS BUGFIX Too little Height of the Provided Parameters Table within the AME Standard T001 The height of the Provided Parameters table within the AME Standard T001 could become so small that only one or two rows were visible although there would have been enough height available for more rows BUGFIX Wrong Capture Delay Value within the MVE Standard T001 Every capture delay value which was entered within the MVE Standard T001 was stored
122. ete or move a Configuration File which is not in status stopped at the moment CHANGE Removing of the Mode Parameter from the ANF OutTCP The Mode parameter has been removed from the ANF OutTCP CHANGE Improved Granularity of the Data Supervision The data supervision performs the check of the accordingly configured Device Profiles each 100 ms now in stead of 1000 ms CHANGE Minimal allowed Data Supervision Time The minimal allowed data supervision time has been changed to 500 ms instead of 1 ms CHANGE Review of the Log Entries about Device Profiles The log messages which are being used for the starting stopping and execution of Device Profiles have been reviewed CHANGE Increased Send Buffer Size for the Data Connection The size of the buffer which is being used for sending of data from the X Tools Server to a client has been in creased to 512 kByte English Release 2014 11 16 81 CMS X Tools Change Log CMS CHANGE Copy and move of items within the MDS Explorer In case data is being copied within the MDS Explorer from one category to another category the default opera tion is a move now The lt Ctrl gt key can be pressed in order to perform a copy instead of the move CHANGE No saving Confirmation for unchanged Monitoring Views In case a Monitoring View has been created and is being closed without a relevant change e g a change within one of the contained tables or ad
123. eters include the data name prefixes the cycle time and the offline time configuration CHANGE Removing of the internal Timeout from the Analyzing Function LoadData Before this change LoadData returned at latest after 200 seconds even in case the to be loaded data was not entirely loaded yet Now LoadData returns only in case a all of the to be loaded data has been loaded or b the parent Analyzing Program is stopped CHANGE Change of the Status Values which can be reported by the Analyzing Function GetStatus The integer values which represent a value status have been changed so that they match the values from the user manual now CHANGE No automatic abort of the Download of the Address Book from an ION SIMATIC TDC T001 In case one branch of the address book can not be downloaded an according log entry is created and the DPE ION SIMATIC TDC T001 continues to attempt to download the next and all following branches Before this modification the download was aborted automatically after the first error has been detected CHANGE Improved Selections within the AME Standard T001 and UFE Standard T001 In case the context menu is called above a not selected item within the AME Standard T001 or UFE Standard T001 the current selection is removed and the item from which the context menu has been called becomes selected CHANGE Increased maximal Size of Analyzing Scripts The maximal size of each Analyzing Script has been increased
124. evice Profiles after a Change of the System Time In case a change of the system time took place while a detaching and re attaching of devices was going on it could happen that all affected Device Profile suspended and did not resume ever again BUGFIX Not empty Directories can t be deleted via the MMS Explorer Deleting of directories which contained files did not work via the MMS Explorer Empty directories were deleted properly but stayed present within the MMX English Release 2014 11 40 81 CMS X Tools Change Log CMS BUGFIX Memory Leak during the detach of simulated Device Every attach of a simulated device caused allocation of some small amount of memory which was not freed again at the moment of the detach of the simulated device In case of big amounts of attaches and detaches of simulated devices the amount of not freed memory could become significant BUGFIX Possible Crash when attempting to edit the Cells of empty Columns within Tables A double click into the cell of an empty typically rightmost column within a table could result in a crash of the X Tools Client BUGFIX Possible Crash during the Start of Device Profiles which contain invalid Ring Buffer Sizes In case the currently to be started Device Profile contained an invalid too low or too big ring buffer size the X Tools Server could end up in a crash BUGFIX Unwanted Search within the System Log Viewer After pressing of the Clear Log Entries button
125. f 2 dimensional Vector Data with a Precision of Decimal32 The exported values of a 2 dimensional vector data were wrong in case the precision of the data was Deci mal32 BUGFIX Possibly missing Data Values within Monitoring Charts In case the currently visualized data disappears e g because the source X Tools Server disconnects and reappears afterwards it could be that no more values of the data were displayed by the Monitoring Chart English Release 2014 11 60 81 CMS X Tools Change Log CMS 28 X Tools V 04 00 IR2 gt X Tools V 04 00 The following changes have been introduced in X Tools V 04 00 FEATURE x64 Variants for x64 Operating Systems All editions of X Tools are available as x32 32 Bit and x64 64 Bit variants from now on The x64 variants can run on 64 bit operating systems as 64 bit processes which allows them to use much bigger amounts of memory FEATURE Support of SIPLUS CMS4000 IFN ANALOGINPUT DIST ANCE Support for the new hardware interface node IFN ANALOGINPUT DISTANCE FEATURE Support for scalar Data In addition to online and offline data also scalar data are supported by X Tools Scalar data are single values without time information and can be used in order to store key values or as parameters for analysis tasks FEATURE MTC Mimic Board T001 The new MTC Mimic Board T001 can be used in order to show the values of data as text in order to show the status of data via signal lights and in order
126. f the X Tools Client after turning on of Advanced Cursors or Frequency Mark ers In case the Advanced Cursors or Frequency Markers of a MTC yn T001 were turned on exactly at the moment when the currently displayed data disappeared the X Tools Client could end up in a crash BUGFIX Wrong Background of Measurement Cursor Labels within the MTC yt T001 The background of measurement cursor labels within the MTC yt T001 could be displayed with a very dark col or in case of Monitoring Views which were stored by older versions of X Tools BUGFIX Avoiding of wrong stop Events within Offline Data Files In case a Storage Profile was configured to store multiple data and one or multiple of these online data were configured with a too small ring buffer wrong stop events could land within all of the created offline data files BUGFIX Improved loading of Offline Data Files which contain wrong stop Events In case a wrong stop event a stop event although there are valid data values afterwards is detected during the loading of offline data files this stop event is ignored and not added to the resulting offline data BUGFIX Improved processing of the fullscreen Command Line Parameter Depending to the current input focus the fullscreen command line parameter could be not working properly in some cases As a result the X Tools Client could appear also in non fullscreen mode and or it did not open the configured Monitoring Views BUGFIX Big Backgro
127. ffline Data Loader was opened the Offline Data Loader was unable to create new offline data locations also after the reconnect of the X Tools Server in some cases BUGFIX Missing Events within offline Data Files Some of the events of signals like source present start stop have not been stored to the offline data files BUGFIX Possible Hang during the Termination of the X Tools Server Under rare conditions it was possible to run into a hang of the X Tools Server because of a dead lock within file monitors during their termination BUGFIX Missing Events within ANS generated online Data The ANS did not add the events which indicate the end of the data availability BUGFIX Overlapping offline Data could prevent the ANS to perform its Calculations In rare cases the STS could create overlapping offline data when loading this data from files The ANS could not process such offline data now the STS does not create overlapping offline data any more BUGFIX Too small Performance of Action based and cyclic Calculations The performance of Action based and cyclic calculations within the ANS has been improved significantly BUGFIX Improved Handling of possibly corrupted Data In rare situations it may happen that the system is unable to properly add additional information to a data e g because of very low CPU time or because of very low available memory Now the affected data is being marked in such cases and it is not bein
128. for a start or stop trigger of a Storage Profile is missing the Storage Profile now is being suspended until the input data for the trigger becomes available again CHANGE Spaces at the End of Data Names within Device Profile Editors In previous versions it was possible to enter data names with spaces at the end within several Device Profile Editors Now all spaces at the end of data names are being removed automatically after editing has been fin ished CHANGE Messages within the Analyzing Model Editor Several messages and icons of messages which occur during the editing within the Analyzing Model Editor have been improved CHANGE System Log Message in Case of a Detected Time Jump from a Device In case X Tools detect a jump in the incoming timestamps of a device an according log entry is being written In order to not overload the System Log in case of an erroneous device this message is not being sent more often than once per minute CHANGE Plausibility Check for the Time Correction Factors of PROFIBUS DP and Serial Port Devices The plausibility check for the time correction factors which already was present for IEEE1394 and socket devic es has been added for PROFIBUS DP and Serial Port devices too CHANGE Preceding and following Probes in Offline Data Files In case there is a value at exactly the start time of an offline data file no preceding probe is inserted into the offline data file any more In addition in case there i
129. g used by the rest of the system any more BUGFIX Possible Crash in Combination with Data of 0 Values Under certain conditions it was possible to run into a crash within the Analyzing System in case an input data of an Analyzing Model Analyzing Script was not available at the start of the Analyzing Model Script and a data of matching name but with 0 values was loaded afterwards BUGFIX Crash of the AME Standard T001 during copy Under certain conditions the AME Standard T001 could crash during a copy operation via the context menu or via the keyboard BUGFIX Constantly increasing Memory Usage of the X Tools Server In case a lot of device simulations have been used in order to create simulated data and in case some of the data definitions within the Device Profiles were configured to an Interval only record mode the X Tools Server seemed to be too slow to process all data and its memory usage was rising all the time BUGFIX Unwanted stop of an Analyzing Model Analyzing Script In case of Action based and cyclic operating modes there was a possibility that the Analyzing Mod el Analyzing Script has stopped automatically although it must suspend BUGFIX Crash when copying of Chart Options A crash could occur in case the chart options were being copied from one MTC to another MTC BUGFIX Bit Arrays of more than 8 Bits Size could not be imported to a Device Profile properly The size of bit arrays after the import always was t
130. ge mode is specified for some data e g Changes only for a Spectrum the SPM Binary T001 outputs an according warning to the system log after the Storage Profile has been started CHANGE Correcting of the Order of Input and Output Arguments of User Functions In case a User Function was called by an Analyzing Script it expected its input and output arguments in the order in which these arguments were added to the UFE Standard T001 Instead the new expected order is identical to the order of input and output arguments as it is defined within the UFE Standard T001 identical to as it can be seen within the User Function Overview dialog and identical to as it is used when lt Alt gt is pressed during the Drag amp Drop of the User Function into the ASE Standard T001 or into the Formula Editor table of the MVE Standard T001 CHANGE Version Checks for X Tools Server X Tools Service and X Tools Tray All binaries of X Tools now ensure that they communicate only with another binary of X Tools in case the major and minor version of both binaries are identical CHANGE Changed default Color within MTCs The default color for Text of selected Items Inactive within the Chart Styles dialog of each Monitoring Chart has been changed to white RGB 255 255 255 CHANGE Number of Harmonics within the Configure Frequency Markers Dialog Until now a value of 0 was used by the MTC yn T001 as Number of Harmonics in
131. h Release 2014 11 24 81 CMS X Tools Change Log CMS as a library like the built in Analyzing Functions and it can be used by other Analyzing Models and Analyzing Scripts like any of the built in Analyzing Functions FEATURE User Function Editor The User Function Editor can be used for the creation and maintaining of User Function Files like the Analyzing Model Editor can be used for the creation and maintaining of Analyzing Models FEATURE Improved Memory Management The available memory of the system is constantly monitored by the X Tools Server now In case the available memory becomes too low the X Tools Server automatically suspends the least important Configuration Files until the system has enough memory again As soon as there is enough free memory available the X Tools Server automatically starts to resume the most important Configuration Files again FEATURE Configurable Line Width of Cursors The width of the lines of the cursors can be configured via the Chart Styles dialog now FEATURE Labels for Measurement Cursors The measurement cursors within each Monitoring Chart now display their number 1 or 2 at the ends of the cursor lines FEATURE Labels for Binary Data within the MTC yt T001 Within the MTC yt T001 the names of binary data now can be shown directly within the curve area FEATURE Storing of Data Snapshots via Monitoring Charts Within its tool bar each Monitoring Chart provides an additiona
132. has used classes instead of ranges BUGFIX Leaving of the Safe Mode The re initialization of the X Tools Server did not disable the safe mode thus the safe mode could not be left without a restart of the X Tools Server BUGFIX Behavior of Output B of CTN WatchGuard T001 Devices in UPS Mode In case the CTN WatchGuard T001 is operated in UPS mode and the system shutdown is being initialized the relay of output B is attracted now When the shutdown is complete the power supply of the USB port is turned off by the computer and the relay is released automatically BUGFIX Timestamp Errors after the Restart of ION PROFIBUS DP T001 Devices There was a possibility to receive log entries about timestamp errors after a restart of ION PROFIBUS DP T001 devices through the data supervision English Release 2014 11 35 81 CMS X Tools Change Log CMS BUGFIX Wrong Undo and Redo within Monitoring Charts In some cases the undo and redo operations did not allow to go back forth step by step In case of an error an arbitrary position and zoom factor could be displayed instead of the expected last next position and zoom factor 2 4 X Tools V 03 03 gt X Tools V 03 04 The following changes have been introduced in X Tools V 03 04 FEATURE Support for Windows 7 as Operating System In addition to Windows XP and Windows Server 2003 now also Windows 7 is supported as operating system FEATURE OPC UA Client X Tools now can act as OPC UA clie
133. he AME Standard T001 displayed the tool tip for the collapsed Analyzing Function even in case the Analyzing Function was expanded BUGFIX Possible Memory Leak when starting and stopping of Device Profiles During the start and stop of Device Profiles there was a possibility that not all of the allocated memory was freed In case of frequent start and stop operations a significant amount of memory could be used BUGFIX Missing resume of Analyzing Models In case Automatic Takeover of changed Configuration Files was set to Do not perform automatic Takeover and a to be started Analyzing Model suspended because of missing input data this Analyzing Model did not resume ever even in case the input data appeared at a later moment BUGFIX Improved Enumeration of IEEE1394 Devices The previous enumeration of IEEE1394 devices stopped at the first device which did not answer properly Now also all of the following devices are checked so that a single device can not stop the operation of all other devic es any more BUGFIX Wrong Communication to IEEE1394 Devices In cases where more than 32 IEEE1394 devices I O Nodes and Interface Nodes were attached to the PC there was a possibility that not all of the attached IEEE1394 devices were recognized by X Tools BUGFIX Possible Hang of Storage Profiles after a Change of the System Time In case the system time was changed back into the past there was a possibility that Storage Profiles could
134. he resulting offline data file could be iden English Release 2014 11 50 81 CMS X Tools Change Log CMS tical to the stop time of the original offline data This is wrong in cases where the stop trigger has fired before the stop time of the original offline data BUGFIX Possibly wrong Default Names of Monitoring Charts Although the name of each Monitoring Chart must be unique within its Monitoring View the MVE Standard T001 could generate default names for new Monitoring Charts which were not unique BUGFIX Improved Detection of Logins under Microsoft Windows 7 Microsoft Windows 7 tends to notify all running applications about a change of the system time at the moment when somebody logs in via Remote Desktop There is no actual change of the system time in this case thus the X Tools Server catches this event and does not restart all of its measurement tasks in this situation restarting of all measurement tasks is the standard reaction to a change of the system time BUGFIX InB2D did not support all types of 2 dimensional Data 2 dimensional data with precisions different to Decimal64 could not be input by the Analyzing Function InB2D as a result the parent Analyzing Program suspended when it detected such a data at its input BUGFIX InB1D did not support all types of 1 dimensional Data 1 dimensional histogram data with precisions different to Decimal64 could not be input by the Analyzing Func tion InB1D
135. here the order of input and output arguments within the User Function Overview dialog was different to the order from the Provided Input Arguments and Provided Output Arguments tables of the UFE Standard T001 BUGFIX Possibly lost Changes within the UFE Standard T001 In case an existing User Function was opened within the UFE and the contents of the Provided Input Argu ments and or Provided Output Arguments tables were changes afterwards these changes could be lost after a following Move up or Move down operation BUGFIX Improper Import of Boolean Values The values of csv files which contain Boolean values could be imported improperly Within X Tools the import ed data values could have values different to 0 and 1 BUGFIX Storages Profiles may not store any Data in case a Space Character is part of the Path In case a space character was present at the end of some file directory name the Storage Profile did not store anything because the internal mechanism for the file directory creation failed There was no indication about this error and from the status of the Storage Profile it looked as if it was running properly BUGFIX Possible Corruption of a User Function In case a function was deleted within the UFE Standard T001 the edited User Function became invalid in case the deleted function provided the current return value of the User Function and additional output arguments BUGFIX Wrong Export o
136. id not match in same cases As a result Output0 could report a value to be present when this was not the case BUGFIX H2D did not set the Status of its Output0 Argument properly The value of the output argument OutReady and the status of the output argument Output0 of the Analyzing Function H2D did not match in same cases As a result Output0 could report a value to be present when this was not the case BUGFIX SetStts did not work within Analyzing Scripts It was not possible to use the Analyzing Function SetStts within Analyzing Scripts BUGFIX Missing Update of Scalar Data Values within the MTC Mimic Board T001 In some cases the MTC Mimic Board T001 did not update the displayed value of a scalar Data which was up dated by an Analyzing Script BUGFIX GetStatus did not accept Input Data of Type String The Analyzing Function GetStatus did not accept input data of type String BUGFIX Possible Crash during the stop of an Interface Profile for the Serial Port T001 Interface In certain situations the stopping of an Interface Profile for the Serial Port T001 interface could cause an inter nal deadlock and a following crash of the X Tools Server BUGFIX Possible Crash after opening of a Monitoring View Opening of a Monitoring View under low memory conditions could cause a crash of the X Tools Client BUGFIX Unnecessary Initializations of internal Buffers could increase the C
137. ig offline data files in case the amount of data after the data reduction fits into the available RAM FEATURE Copying of the Contents of the Cursor Tables from Monitoring Charts The contents of the Cursor Tables of Monitoring Charts can be selected and copied to the clipboard of Windows now From there these contents can be copied into any other compatible Windows application FEATURE Enabling Disabling of multiple Rows within Interface Profile Editors The additional context menu items Enable and Disable are available within the Connections tables of all Inter face Profile Editors now In combination with multiple selections of rows these context menu items can be used in order to enable disable the entries of multiple rows at once FEATURE Additional Analyzing Function GenerateAlarmBand The additional Analyzing Function GenerateAlarmBand generates an 1 dimensional buffer with information about the boundaries of an alarm band This information can be used to monitor a spectrum with the ANF Mon itorAlarmSpectrum FEATURE Additional Analyzing Function MonitorAlarmSpectrum The additional Analyzing Function MonitorAlarmSpectrum calculates alarm spectrums with the information generated by GenerateAlarmBand and monitors an input spectrum FEATURE Additional Analyzing Function GetBufferMember The additional Analyzing Function GetBufferMember returns the specified value from an 1 dimensional input buffer FEATURE Ad
138. iguration Files before their containing directory is being expanded within the explorer trees In case of a lot and or of big Configuration Files which are distributed via sub directories the expanding of sub directories becomes much faster with this kind of updating FEATURE Selection of Input Arguments within the AME Standard T001 via the Cursor Keys lt Cursor up gt and lt Cursor down gt now can be used in case to move the input arguments of an Analyzing Func tion up and down FEATURE Additional Access to the Parameters of Analyzing Models Scripts for Analyzing Functions Analyzing Functions are now able also in sequential mode to access the parameters of Analyzing Models and Analyzing Scripts e g the output data class and the operating mode FEATURE Re Initialization of the X Tools Server via the X Tools Client Via the context menu of a currently connected X Tools Server within the MMS Explorer the X Tools Server can be re initialized now This functionality is useful especially in scenarios where the X Tools Client and the X Tools Server are running at different computers and in case a global option which requires a restart of the X Tools Server has been changed English Release 2014 11 11 81 CMS X Tools Change Log CMS FEATURE Adding of Notifications from IEEE1394 I O Nodes to the System Log IEEE1394 I O Nodes can send notifications which contain information about some internal status e g a detect ed error during th
139. ime Errors after detaching and re attaching of IEEE1394 Devices There was a possibility to receive a wrong log entry about a detected time error after detaching and re attaching of an IEEE1394 device BUGFIX Improper Size of Message Boxes On some screen resolutions there was a possibility to receive an improper size for a message box As a result the displayed text could be cut BUGFIX Improved Security during the simultaneous Connection of multiple Clients In case multiple clients were connecting to one X Tools Server simultaneously there was a possibility that the X Tools Server recognized two sockets from two different clients as one single connection Such a configuration can not work and produced undetermined results BUGFIX Possible Crash during loading of several 10 000 offline Data Files at once There was a possibility to end up in a crash in case huge amounts of offline data several 10 000 files were loaded at once BUGFIX No File Splitting in case of the Post Trigger Setting On with parallel Storage In case the post trigger setting On with parallel Storage was configured it was possible to end up in a configu ration where no file splitting was performed any more BUGFIX Ignored Reconnect Settings The reconnect settings from the Global Options Editor of the X Tools Client were ignored in case the specified destination port was not reachable In such a situation multiple connection attempts could take place ea
140. in order to check whether some entry a value or a string is present within a ini file FEATURE Additional Analyzing Function GetCalculationTime The new Analyzing Function GetCalculationTime can be used in order to determine the timestamp which is being processed by the current calculation cycle FEATURE GetStartTime also accepts Strings and Variables as Data Name In addition to the offline data identifier e g DataName also a string e g DataName or a variable e g DataName can be passed to the Analyzing Function GetStartTime now FEATURE GetStopTime also accepts Strings and Variables as Data Name In addition to the offline data identifier e g DataName also a string e g DataName or a variable e g DataName can be passed to the Analyzing Function GetStopTime now FEATURE GetNumberOfValues also accepts Strings and Variables as Data Name In addition to the offline data identifier e g DataName also a string e g DataName or a variable e g DataName can be passed to the Analyzing Function GetNumberOfValues now FEATURE Configurable Output Time Base for Analyzing Models and Analyzing Scripts The Output Time Base of Analyzing Models and Analyzing Script can be configured now This setting allows to choose the time base time zone of the offline data which is created by each Analyzing Model Analyzing Script FEATURE Go to Parameter Context Menu Item
141. in the AME Standard T001 Under certain conditions it was possible that lt F2 gt stopped to enter the edit mode of input arguments Pressing of lt F2 gt did not have any effects in such cases BUGFIX Output Analyzing Function using Precision Integer8 Setting of the Analyzing Function property Precision to Integer8 for output functions did not work properly English Release 2014 11 18 81 CMS X Tools Change Log CMS BUGFIX Speedup of the Compression between X Tools Client and X Tools Server In case the X Tools Client and the X Tools Server were started up simultaneously a lot of CPU time has been wasted unnecessarily with the compression of their communication BUGFIX Immortal Message Box in case of Missing Storage Profile Editor and Loading Profile Editor In case a Storage Profile or Loading Profile is being dropped when there is no Storage Profile Editor or Loading Profile Editor available an according message box popped up Closing of this message box automatically opened the same message box again BUGFIX Reading of the Address Book of an ION SIMATIC TDC T001 In case the X Tools Client was connected to two X Tools Servers and both of these X Tools Server had an ION SIMATIC TDC T001 with identical name attached the address book could be loaded only from one of them BUGFIX Creating of Locations via the Offline Data Loader In case the connection to the target X Tools Server broke down unusually while the O
142. in the User Accounts Editor it still was possible to store the user accounts BUGFIX Storing of Main Profiles with an invalid Pair of Command and Data Ports In case the same value was specified for the command and for the data port within a Main Profile it still was possible to store the Main Profile and there was no indication to the user BUGFIX Always visible Legend within a Monitoring Chart Under certain conditions it was possible to enter a state of the legend where it was impossible to hide it BUGFIX Improper Initialization of the Time Zone of t Axes after re opening of a Monitoring View The time zone of t axes was not initialized properly after re opening of a Monitoring View As a result another group of t axes could be created in case additional data was dragged into the Monitoring View instead of adding this data to the already existing group BUGFIX Possible Crash after multiple Starts of a Device Profile for an ION SIMOTION T001 Under certain conditions it was possible to end up in a crash in case the Device Profile and parent Interface Profile of an ION SIMOTION T001 was stopped and started multiple times BUGFIX Mismatch in the displayed Data Values between the ODL Binary T001 and the MDS Explorer In case of offline data files which contain only one value the MDS Explorer displayed a value of O instead 1 present probes under certain circumstances BUGFIX Possible Hang or Crash when arranging of Windows in automatic
143. ing View the previously configured background color of the present Monitoring Charts was not restored Instead the default color was present within the Monitoring Charts after each opening of their Monitoring View BUGFIX Hang in Case the current Time Zone is being changed during the Termination In case the X Tools Server was terminated via its context menu and the time zone of the operating system has been change during the termination there was a possibility to hang X Tools BUGFIX Too many Log Entries about too many Log Entries There was a protection against log entry floods which does not allow a configuration file to put more than 10 000 entries into the System Log during one execution In case 10 000 log entries have been reached there was one additional log entry to the System Log for each additional log entry from the configuration file Now it is possible to put up to 250 entries into the System Log during 5 seconds BUGFIX Double Info Node for Storage Process Modules within the Storage System Explorer In case there were multiple Storage Process Modules present the Storage System Explorer could display more than one Info node for each of them BUGFIX Missing Context Menu Items for Offline Data Files within the Offline Data Loader The Expand and Collapse context menu items for Offline Data files were not displayed until they had been expanded at least once BUGFIX Possible Crash during the Termination of the
144. ing read and displayed from the end to the beginning In addition the Next Entries and Previous Entries buttons of the System Log Viewer can be used in order to scroll to the next or previous entries FEATURE Direct Editing of Input Arguments within the Analyzing Model Editor In order to change the value of an input argument of an Analyzing Function within the Analyzing Model Editor the according input argument can be selected via the mouse and the lt F2 gt key can be pressed afterwards in order to start editing of the value directly Like before a double click onto the input argument opens the Analyz ing Function Properties dialog where all input arguments can be edited within a table FEATURE Visible Sequence IDs within Error Messages of Analyzing Models In case an error message is being created by an Analyzing Model the sequence ID of the causing Analyzing Function is added as part of the message In several cases also the causing arguments can be highlighted di rectly within the Analyzing Model FEATURE Execution IDs for the System Log Entries of all Configuration File Types At a start of each configuration file Main Profile Interface Profile Device Profile Monitoring View Analyzing Model Analyzing Script or Storage Profile a unique execution ID is being assigned This execution ID can be used within the System Log Viewer in order to display only the messages which belong to a certain execution of a certain configuration file
145. int in time could be changed BUGFIX Possible processing of a Random Value through the Analyzing Function InAAF In case the Analyzing Function InAAF was processing online data it could read one wrong input value from the ring buffer of the online data each time when it has passed the end the highest index of the ring buffer English Release 2014 11 73 81 CMS X Tools Change Log CMS 2 11 X Tools V 04 02 IR1 gt X Tools V 04 02 The following changes have been introduced in X Tools V 04 02 FEATURE Graphical editing of Spectrum Envelopes The MTC yn T001 can be used now in order to create a spectrum envelope for a given reference spectrum Both frequency spectrum envelopes and order spectrum envelopes are supported The creation and modifica tion of spectrum envelopes is fully interactive can be be done both by mouse and via configuration dialogs FEATURE Viewing of Violations of Spectrum Envelopes The MTC yn T001 can be used now in order to show all violations of a spectrum envelope through the currently visualized spectrum FEATURE Additional Analyzing Function GetAlrmBnd The new Analyzing Function GetAlrmBnd can be used in order to receive information about the properties center width amplitudes of a certain alarm band of a spectrum envelope FEATURE Additional Analyzing Function MonSpmEnv2 The new Analyzing Function MonSpmEnv2 can be used in order to monitor whether the specified frequency or ord
146. isplayed and all older values were not visible any more within the MTC yt T001 BUGFIX Prefix Operators for the Function Arguments of Analyzing Scripts were ignored Within the list of function arguments Analyzing Scripts ignored the prefix operators and e g Variable or Variable Prefix operators did not have any effects and there also was no error message to inform the user BUGFIX Possible Memory Leak in case of low Memory Conditions during loading of Offline Data In case X Tools ran out of memory during the loading of offline data the loading was aborted but the memory of the already allocated offline data could not be freed any more until the X Tools Server was restarted BUGFIX Wrong Message Box while removing of Offline Data from the MDS Explorer In case multiple offline data categories contained the same offline data and all of these offline data were re moved at once either via the lt Del gt key or via the Remove context menu item a message box could appear which indicated an error during the remove although actually there was no error BUGFIX The Menu Bar could process Keys even in Cases where it did not have the Input Focus In case a button from the menu bar was selected via the lt Tab gt key and the input focus was changed by the mouse to a cell of a table of the same dialog some dialogs executed the menu bar button when lt Enter gt was pressed afterwards instead of executing
147. itForConfigurationFile The additional Analyzing Function WaitForConfigurationFile blocks the execution of a sequential Analyzing Script until the specified configuration file reaches one of the specified states FEATURE Additional Analyzing Function WaitForStartEventbyData The additional Analyzing Function WaitForStartEventbyData blocks the execution of a sequential Analyzing Script until the specified time event has been reached FEATURE Additional Analyzing Function IIRBandPassFilterChebyshev1 The additional Analyzing Function IIRBandPassFilterChebyshev1 calculates an up to 10 th order IIR Cheby shev1 filter FEATURE Additional Analyzing Function IIRBandStopFilterChebyshev1 The additional Analyzing Function IIRBandStopFilterChebyshev1 calculates an up to 10 th order IIR Cheby shev1 filter FEATURE Additional Analyzing Function lIIRHighPassFilterChebyshev1 The additional Analyzing Function IIRHighPassFilterChebyshev1 calculates an up to 20 th order IIR Cheby shev1 filter English Release 2014 11 12 81 CMS X Tools Change Log CMS FEATURE Additional Analyzing Function IIRLowPassFilterChebyshev1 The additional Analyzing Function IIRLowPassFilterChebyshev1 calculates an up to 20 th order IIR Cheby shev1 filter FEATURE Additional Analyzing Function IIRBandPassFilterChebyshev2 The additional Analyzing Function IIRBandPassFilterChebyshev2 calculates an up to 10 th order IIR Cheby shev2 filter
148. ithout Windows administrator rights because these rights are not needed for most of its operations In case there are Windows administrator rights necessary for an operation like for changes to the X Tools Service according messages and log entries are provided and the X Tools Server must be started with Windows administrator rights in order to become able to perform the operation CHANGE Signature for Executables All executables exe of X Tools are signed now and report Siemens AG as verified publisher CHANGE Moving to the ALM V 5 3 1 The Automation License Manager ALM V 5 3 1 is used by X Tools from now on CHANGE More tolerant Timeout within the DPE OPC UA T001 The DPE OPC UA T001 reads the to be expanded nodes in smaller potions now This allows to read also big ger OPC UA address spaces CHANGE New ALM Licenses The ALM licenses from V 04 01 can not be used for V 04 02 anymore Instead a new or an upgrade license must be used in order to run V 04 02 CHANGE Modified Selection of Points through the Analyzing Function Extrapolate The Analyzing Function Extrapolate uses a different strategy for the selection of points of the input data which are used for the calculation of the polynom The target of the new strategy is to achieve that the extrapolated data goes exactly through the start and the stop values of the input data BUGFIX Wrong loading of Offline Data Files with single Probes In case multiple offlin
149. itialization of the X Tools Client In case the X Tools Server was re initialized while there were still offline data loading tasks in the queue the remaining tasks were continued and the according offline data was loaded after the re initialization of the X Tools Server BUGFIX Possible Memory Leak after the re initialization of the X Tools Client In case the X Tools Server was re initialized while there was still some offline data loading in progress some fragments of memory could stay present also after the re initialization BUGFIX Possible Crash when opening of Monitoring Views which contain an empty MTC ynm T001 The X Tools Client could crash in case a Monitoring View was attempted to be opened which contained an empty MTC ynm T001 BUGFIX Possible Hang in case big Amounts of Text are pasted into the ASE Standard T001 The X Tools Client could hang in case a big amount of text was pasted into the edit control of the ASE Standard T001 Now not more than 32 000 characters can be pasted into this edit control BUGFIX Lost Visualization in case of a detach and re attach of a Device The currently paused visualization within a Monitoring View could loose all of its contained values in case the source device of the visualized data was detached and re attached BUGFIX Usage of Arrays within Time Slice based Analyzing Scripts It was not possible to use arrays within time slice based Analyzing Scripts Starting of such Analyzing Scripts
150. itoring Charts FEATURE Configurable Path and File Name for Monitoring View Reports The path and the file name of the report files which are created by Monitoring Views can be configured now via the new Storage Path and Storage File Name parameters of the Monitoring View Parameters table within the MVE Standard T001 FEATURE Improved Support for Time Zones within Analyzing Models and Analyzing Scripts The new option Output Time Base within the AME Standard T001 and ASE Standard T001 can be used in order to configure the time base time zone of the offline data which is created by the currently configured Analyzing Model Analyzing Script FEATURE Improved Support for Time Zones within Monitoring Charts The new option Time Base within the Manual scale t Axis respective Manual scale Renderer dialogs of Monitoring Charts can be used in order to configure the time base time zone of the data which is visualized by the Monitoring Chart FEATURE Splitting of Log Files In order to avoid endless growing of log files the new global options Maximum Log File Size and Maximum Log File Time can be used in order to configure the maximal allowed size and time of a log file In case either the maximal allowed size or the maximal allowed time is exceeded the log file is closed and a new log file is started FEATURE Support of Frequency Markers for the Analysis of Order Spectrums The MTC yn T001 now all
151. l Analyzing Function GetTime The additional Analyzing Function GetTime returns the amount of seconds which have elapsed since 1970 01 01 for the GMT time zone FEATURE Additional Analyzing Function MonitorConfigurationFile The additional Analyzing Function MonitorConfigurationFile monitors the state of the specified configuration file FEATURE Additional Analyzing Function MonitorDevice The additional Analyzing Function MonitorDevice monitors state of connected devices FEATURE Additional Analyzing Function MonitorDisk The additional Analyzing Function MonitorDisk monitors changes in the available space of a disk FEATURE Additional Analyzing Function MonitorSystemLog The additional Analyzing Function MonitorSystemLog monitors contents of XTS system log FEATURE Additional Analyzing Function SendEmail The additional Analyzing Function SendEmail sends textual messages via email to specified recipient FEATURE Additional Analyzing Function Resample The additional Analyzing Function Resample creates a 1 dimensional buffer with re sampled online or offline input data or values CHANGE One Device Profile Editor for all S7 Software I O Nodes All supported S7 software I O Nodes can be configured with the same Device Profile Editor DPE ION SIMATIC S7 This editor replaces the following editors DPE ION SIMATIC S7 300 T001 DPE ION SIMATIC S7 400 T001 and DPE ION SIMATIC S7 400 T002 CHANGE Disabling of
152. l button which can be used in order store the currently visualized data to the disk FEATURE Progress Dialogs for storing loading and exporting Operations Whenever a storing loading or exporting operation is in progress an according dialog is being displayed The displayed dialog shows the current status of the ongoing operation and also can be used in order to cancel the ongoing operation FEATURE Dialog for the direct Configuration of the Communication Ports of the X Tools Server Via the context menu of the X Tools Server from the task tray the X Tools Server Connectivity dialog can be called now There the current values of both communication ports can be seen and changed to other values FEATURE Status Dialog for the X Tools Server Via the context menu of the X Tools Server from the task tray the X Tools Server Status dialog can be called now There the basic information about the currently running Configuration Files is being displayed FEATURE Automatic Assigning of Sequence IDs within the Analyzing Model Editor The Analyzing Model Editor now can be used in order to assign the sequence IDs of the contained Analyzing Functions automatically The manual possibility for the configuration also stays available FEATURE Restoring of Monitoring Views during the Startup of the X Tools Client The new global option Restore the Monitoring Views from the last Session can be used in order to configure the X Tools Client to automati
153. log entry sometimes reported a stop of the Analyzing Model Analyzing Script BUGFIX Wrong Log Entry after appending of offline Data Files of mismatching Data Type In case the to be appended offline data files contained a data type which was different to the data type of the already present offline data with matching name there was a log entry that the header of the file could not be read BUGFIX Possible Hang of the X Tools Client in case of missing DLLs of the X Tools Server In case the ANE dll MTE dll or STE dll binaries of a connected X Tools Server were missing the X Tools Cli ent could hang or react very slow BUGFIX Wrong Detection of wrong Interface Types In case an Interface Profile had been started and stopped no Interface Profile of identical name could be start ed for another interface type BUGFIX Not working implicit Outputs within Time Slice based Analyzing Scripts Implicit outputs like A Bffr GenWF 1024 O false true did not work within Analyzing Scripts in case the internal output Analyzing Function was different to Out BUGFIX Time Domain mismatch within the Advanced Append Overwrite Export Dialogs In case the time domain which was specified within the Advanced Append Overwrite Export dialogs did not match the time domain of the to be appended overwritten exported offline data file the append overwrite export still attempted to process the offline data file Now an according erro
154. ly into the Chart Options dialog BUGFIX Other Windows can not be opened in case the MTS Explorer is undocked In case the MTS Explorer was undocked it was not possible to open any other window within the MTS Work space BUGFIX Changed Names of simulated Devices are not applied In case there was an Interface Profile for the simulation interface started already and another Interface Profile for the simulation interface is started afterwards the names of the simulated devices were not updated accord ing to the configuration of the new Interface Profile BUGFIX Automatic Startup of the X Tools Server may fail in case of Spaces within the Path Name In case the path to the executable of the X Tools Server contained space characters the automatic startup which is configurable via the Global Options Editor could fail BUGFIX Possible Hung after multiple Changes of the System Time In case multiple changes of the system time occurred within short time a few seconds there was a possibility to end up in a hang of the X Tools Server BUGFIX Possible Disorder when requesting Data from an ION SIMATIC TDC T001 In case Boolean and non Boolean values were requested from an ION SIMATIC TDC T001 simultaneously there was a possibility to receive corrupted data because of an disorder in the internal byte assignment BUGFIX Missing Status Update after renaming of Directories In case the directory of a start Configuration File e g a Devic
155. ly loaded offline data in these improperly loaded offline data some parts from the original offline data files could be missing BUGFIX Crash during the export of very big offline Data Files After the export of big offline data files resulting files of a few 100 MByte there was a possibility to receive a crash BUGFIX Wrong Dates within the Tool Tip of Monitoring Charts Under rate conditions it was possible to receive wrong dates within the tool tips of Monitoring Charts BUGFIX Wrong Timestamps within the Data from CTN WatchGuard T001 Devices In case the Device Profile of a CTN WatchGuard T001 device was configured to output binary data some timestamps of the incoming data were shifted in time wrongly English Release 2014 11 20 81 CMS X Tools Change Log CMS BUGFIX Support for the Mouse Wheel at the t axis of the MTC yt T001 The mouse wheel did not work at the t axis of the MTC yt T001 BUGFIX Outdated Information about attached CTN WatchGuard T001 Devices Basic information like the device name or its version was read only at the moment of the first connect Thus in case one device was detached and another devices was attached afterwards it could happen that still the infor mation from the previously attached device was used by X Tools BUGFIX Possible Crash during the storing of Data Storage Profiles with start and stop triggers could crash in rare conditions at the moment when a trigger was added or removed BU
156. ming was still in progress the X Tools Server could end up in a hang and a following crash BUGFIX An Analyzing Model may not resume at the Moment when its Input Data appears Under certain conditions an internal race condition could keep an Analyzing Model from resuming even after all of its necessary input data became available BUGFIX Too many Log Entries from MonCF in case it was used in Action based Operating Modes In case the Analyzing Function MonCF was used in an action based operating mode a single change of the state of the to be monitored Configuration File could cause continuous never ending log entries BUGFIX Possibly missing Data from OPC UA Servers In case multiple data were received from an OPC UA server and in case some of these data did not change ever the X Tools Server could run into timestamp errors and as a result it was not possible to use e g visual ize such a data BUGFIX No writing of Data to an OPC UA Server In case a Device Profile for an OPC UA server was configured to write data values to the OPC UA server it could happen that X Tools did not pass any value to the OPC UA server after the start of the Device Profile BUGFIX Too early Status Change to stopped from Storage Profiles A Storage Profile could reach the status stopped before it has finished to write all of its offline data values to the disk As a result a following attempt to load the latest offline data could fail After
157. n do Redo buttons now which calls the Chart Options dialog in order to change the size of the undo and redo buffers FEATURE Detection of Heap Corruption In case a corruption of the heap memory of X Tools is being detected a dump is being created automatically FEATURE Additional Global Option General logging Mode The General logging Mode can be used in order to configure which entries shall land within the log file and English Release 2014 11 26 81 CMS X Tools Change Log CMS which ones not The setting uses the priority of the log entry in order to decide whether it shall land within the log file or not FEATURE Additional Global Option Storage System logging Mode The Storage System logging Mode can be used in order to configure whether log entries about detected start or stop trigger events shall be added to the log file or not FEATURE Additional Analyzing Function ConvSpm The additional Analyzing Function ConvSpm can be used in order to integrate or derivate a spectrum For example an acceleration spectrum can be integrated into a velocity spectrum FEATURE Position Bars for the Drag amp Drop of Data into the Legend of Monitoring Charts Whenever a data is being dragged into the legend of a Monitoring Chart a position bar now displays the exact position to which the data would be dropped according to the current mouse position CHANGE Avoiding of massive Amounts of Log Entries in case
158. n Interface Profile for the socket interface as well as the system log entries which appear whenever a socket device gets connected disconnected have been improved CHANGE Meaning of the Storage Profile Triggers for Intervals The definition of the start conditions for the start and stop triggers of Storage Profiles which base on intervals join leave inside outside have been improved and the implementation has been slightly modified accordingly CHANGE Default Buffer Size for Analyzing Functions which produce extended Data Types The default size of the data buffer of data of extended data types e g a spectrum has been changed from 1 000 to 50 values in order to use less RAM in the default configuration BUGFIX Start Time of relative offline Data from Analyzing Models and Analyzing Scripts In previous versions the start time of relative offline data which was output by Analyzing Models and Analyzing Scripts was close to the specified Minimum Time Value but not exactly the specified Minimum Time Value there was a small jitter which was depending to the start time of the Analyzing Model Analyzing Script Now the start time of such data always matches the specified Minimum Time Value exactly English Release 2014 11 7 81 CMS X Tools Change Log CMS BUGFIX Time Zone Information within Offline Data Files In previous versions the time zone information bias and description was not stored by offline data files Now each created offline
159. n OutOrbit can be used in order to output a calculated orbit as online or offline data FEATURE Additional Analyzing Function InTCP The additional Analyzing Function InTCP can be used in order to receive TCP packets which are being sent by any external application or device The data from the received TCP packet can be decoded via GetVFrmB1D afterwards and the extracted values can be used like all other data values within X Tools FEATURE Additional Analyzing Function GetVFrmB1D The additional Analyzing Function GetVFrmB1D can be used in order to extract one or multiple data values out from the buffer which has been received via InTCP FEATURE Additional Analyzing Function GetVFrmSD The additional Analyzing Function GetVFrmSD can be used in order to extract a single value out of a time series of data FEATURE Additional Analyzing Function Pause The additional Analyzing Function Pause can be used in order to pause the execution of an already started Configuration File An according example Analyzing Script has been added to the example location FEATURE Additional Analyzing Function Continue The additional Analyzing Function Continue can be used in order to continue the execution of a currently paused Configuration File An according example Analyzing Script has been added to the example location FEATURE Loading of Data from the SIPLUS CMS2000 System The ODL Binary T001 has been replaced by the ODL Standard
160. n Output Arguments It was not possible to connect the InO In7 inputs of the Analyzing Function OR to output arguments of non Boolean types BUGFIX Link Boxes within the MTC Mimic Board T001 did not support to enter a manually It was not possible to enter a Backslash manually into the Edit Link Box dialog of the MTC Mimic Board TOO1 BUGFIX Passing of Parameters to X Tools via the URI Scheme could open another X Tools Client Under certain circumstances passing of parameters to X Tools via the Firefox web browser could open another X Tools Client instead of reusing of the already present X Tools Client BUGFIX Possible Crash during the renaming of an Offline Data via the MDS Explorer In case an offline data was renamed within the MDS Explorer at the moment when it was removed the X Tools Client could end up in a crash BUGFIX Possible Crash in case of Access to Data which were already deleted from the MDS Explorer In case the context menu of a data from the MDS Explorer was opened and afterwards the data got removed from the MDS Explorer the X Tools Client could end up in a crash at the moment when any of the items of the still open context menu was chosen BUGFIX H1D did not set the Status of its Output0 Argument properly The value of the output argument OutReady and the status of the output argument Output0 of the Analyzing English Release 2014 11 71 81 CMS X Tools Change Log CMS Function H1D d
161. n case an Analyzing Function is detected by X Tools which has not been provided by the SIPLUS CMS team but by a third party developer an according log entry is created by the X Tools Server The log entry also pro vides the detailed version of the detected Analyzing Function FEATURE Advanced Cursors within the MTC yn T001 The newly added advanced cursors within the MTC yn T001 can be used in order to visualize and measure harmonics subharmonics and sidebands of data English Release 2014 11 44 81 CMS X Tools Change Log CMS FEATURE Frequency Markers within the MTC yn T001 The newly added frequency markers within the MTC yn T001 can be used in order to visualize and measure any frequencies of interest A configurable Main Frequency Marker can be linked to a data like a rotary frequen cy and can be used in order to derive further information like defect frequencies harmonics subharmonics or sidebands directly from the current status of the monitored component FEATURE Quality of Service for online Data Each online data now provides detailed information about the last moment in time until which it is valid In case of different record modes e g Changes only and or in case of very slow sampled data this last moment in time can be far after the last timestamp within the ring buffer Knowing the last moment in time all following systems know exactly until which moment in time they can perform their processing One of the benefi
162. nal Analyzing Function LoadData The new Analyzing Function LoadData can be used in order to load data from offline data files and to make this data available as offline data FEATURE Additional Analyzing Function AddV2D The new Analyzing Function AddV2D can be used in order to add two 2 dimensional vectors FEATURE Additional Monitoring Chart MTC Vector2D T001 The new Monitoring Chart MTC Vector2D T001 can be used in order to visualize 2 dimensional vector data FEATURE Automatic Reports Monitoring Views now can be configured to create reports automatically Therefore also Monitoring Views can be started now a started Monitoring View creates a report of its contained Monitoring Charts whenever the specified trigger condition occurs This functionality of automatic reports is performed completely by the X Tools Server and does not need a connected X Tools Client during runtime FEATURE Fast Analysis via the MDS Explorer Within the ANS Explorer a Fast Analysis location can be created now All Analyzing Scripts which are present below this location can be called via the context menu entry Fast Analysis of the MDS Explorer The currently selected online or offline data from the MDS Explorer is used as input for the chosen Analyzing Script FEATURE Advanced File Associations X Tools now registers its file associations xtc xts and wav at Windows so that X Tools is started auto matically in case the user do
163. name can be specified within Main Profiles now in order to identify the computer and X Tools Server to which the X Tools Client shall connect FEATURE Exit Confirmation The X Tools Client can be configured to request an exit confirmation before it is being closed FEATURE Reporting of low Ring Buffer Sizes In case the ring buffer for the values of an online data is too small an according warning is being added to the system log FEATURE Switchable Unit of relative Timestamps Within the cursor table of the MTC yt T001 the unit of the timestamps of offline data with relative timestamps now can be switched between text ns us ms seconds minutes hours and days FEATURE Email Notifications for various System Events Via the Analyzing System it is possible now to send an email in case of an occurring event like the appearing of a certain log message reaching of some hard disk threshold changes in the state of a Configuration File or changes in the state of a device FEATURE Safe Boot Mode In case the safe boot mode is being enabled the X Tools Server can log all starts of Configuration Files In case of severe errors the X Tools Server does not automatically start the affected Configuration File during its next startup Together with the X Tools Service which can restart the X Tools Server in case of e g acrashora hang the safe boot mode is able to restore the X Tools Server in most cases FEATURE Additional State Triggering
164. nce BUGFIX Possibly permanent suspend of Analyzing Models and Analyzing Scripts The following Analyzing Functions contained an error which could cause a permanent suspend of their parent Analyzing Model or Analyzing Script AppBhann AppBlack AppBlett AppAppHamm AppHann Avg Spm ConvSpm Cpstr EnvHlb FFT Impulser Random RFC and TLC BUGFIX Memory Leak within the Analyzing Function TLC A memory leak could occur at each call of this Analyzing Function e g once each cycle of the parent Analyzing Model Analyzing Script BUGFIX Possible Memory Leak when storing of online Data In case the online data of a currently running Storage Profile disappeared for the first time e g because its Device Profile was stopped the memory of this online data was not released BUGFIX Improper handling of Locations which point to removable Disks Detaching of removable disks was not detected by X Tools even in case a location has pointed to a directory at this disk The behavior while reading and writing of files from and to such locations was undefined and could show different kinds of errors BUGFIX Possible Time Errors after the re attach of a Bus Cable Time errors could be detected after a detach and re attach of the bus cable of the following devices ION ARCNET Spy T001 ION CS31 Spy T001 and ION SIMOLINK T001 BUGFIX Expanding of the Analyzing Function RFC within the AME Standard T001 The Analyzing Fu
165. nction RFC could not be expanded within the AME Standard T001 after it was moved at least once English Release 2014 11 39 81 CMS X Tools Change Log CMS BUGFIX Possible Time Errors after Delays in the Socket Communication In case timeouts occurred during the socket UDP or TCP communication to a single device e g to a software l O Node these timeouts could freeze all socket communications When the processing of socket communica tion was resumed the processing of the old data packets which arrived in the meanwhile could lead to time errors BUGFIX Improved Memory Usage for loaded Offline Data In case of append operations on base of data from identical time intervals the allocated memory could be much higher than actually needed Now the allocated amount of memory matches exactly the number of probes with in the loaded offline data BUGFIX Input of invalid Characters within the X Tools Server Connectivity Dialog Although the allowed range for the configurable ports is 1 65536 it was possible to insert non integer charac ters like abc within this dialog BUGFIX Possible Crash when closing of a minimized X Tools Client In case a minimized X Tools Client was closed via the context menu a crash could occur BUGFIX Possibly wrong opening of a MTC yx T001 In case a MTC yt T001 has been converted into a MTC yx T001 there was a possibility that the original data from the MTC yt T001 got lost In this cas
166. nding of Storage Profiles in case of an unavailable Storage Location In case the Storage Location of a Storage Profile was unavailable or disappeared the Storage Profile did not suspend BUGFIX CPU usage of the X Tools Server at the Moment of File Splitting There were several cases possible where the CPU usage was rising up to 100 for several seconds at the moment of the file splitting BUGFIX Memory Leak in case of File Splitting The state of visibility of Toolbar within Monitoring Views is stored BUGFIX Memory Allocation while Storing Data Memory has been allocated wrongly in case the input data of a Storage Profile was not available BUGFIX Possible Crash when running a Storage Profile with Interval only There was a possibility for a crash in case a Storage Profile contained a Storage Mode of Interval only BUGFIX Too many stored Data after the Stop Trigger Event Under certain conditions it was possible that there were some data values being put into the offline data file which had timestamps after the stop event BUGFIX STS works in two Directories after it was suspended Under certain conditions it was possible that a single Storage Profile continued to store its data into two different directories simultaneously This happened sometimes after the Storage Profile was suspended because of low memory conditions BUGFIX Crash when loading of offline Data A crash could occur during the loading of offline data in
167. nline Data The Analyzing Function GetVFrmSD suspended its parent Analyzing Model Analyzing Script directly after the start in case it was used to get the value from an online data English Release 2014 11 76 81 CMS X Tools Change Log CMS BUGFIX Suspend through the Analyzing Function OutOrbit in case of unsupported Precisions In case the Analyzing Function OutOrbit was configured with a precision that it did not support the Analyzing Function suspended its parent Analyzing Model Analyzing Script Instead an according warning log entry is created now and the Analyzing Function uses the closest supported precision automatically BUGFIX Possible Crash in case the EnOutSpm Input Argument was false The X Tools Server could end up with a crash in case the Analyzing Function MonAlrmSpm was called with a value of false for its input argument EnOutSpm BUGFIX Possible Deadlock through started Monitoring Views A started Monitoring View could end up in a deadlock which caused that client connection slots were not re leased anymore In addition this deadlock also could cause a constant rising of the memory usage through the X Tools Server BUGFIX Improved handling of low Ring Buffer Sizes through Storage Profiles In case a Storage Profile had to store an online data whose ring buffer was very small an online data which contained less than 5 seconds of data within its ring buffer the Storage Profile may not have dete
168. nnns 61 2 9 X Tools V 04 00 gt X T00lS DA Did ande 67 2 10 X Tools V 04 01 gt X Tools V 04 02 l Rd ooccccoonoccccconoccnccononcccnnnoncncnnnncnnnnnonnnnnnnnn nn nnnnancnc nana ncnnnnnns 68 2 11 X Tools V 04 02 IR1 gt X Tools V DA Ol oooocccoonocccccononcnccononcncnnnancncnnnncncnnnonnnnnnnn nn nc canon cnc i rnaar anana 74 3 Listiof Abbreviations ii td acid 80 4 Contact Informations inanir a alaba 81 English Release 2014 11 3 81 CMS X Tools Change Log CMS 1 Preface 1 1 Purpose of this Document This document contains the change log for the software e CMS X Tools of CMS product line In order to learn about the usage and functionality of CMS X Tools the following documentation is available e CMS X Tools User Manual 01 Introduction o provides an introduction into the basic functionalities of CMS X Tools e CMS X Tools User Manual 02 Master Data System o provides detailed information about the functionality which is provided by the Master Data System e CMS X Tools User Manual 03 Main Management System o provides detailed information about the functionality which is provided by the Main Management Sys tem e CMS X Tools User Manual 04 Device Management System o provides detailed information about the functionality which is provided by the Device Management System e CMS X Tools User Manual 05 Monitoring System o provides detailed information about the functionality which is provided by the
169. not disturb any other task of X Tools any more CHANGE Removing of the Auto scroll Cursor Table option within the Chart Options Dialog The Auto scroll Cursor Table option has been removed Now the cursor table always is being scrolled auto matically so that the currently clicked entry from the legend becomes visible within the cursor table CHANGE The Analyzing Function Random replaces the built in Random of Analyzing Scripts The previously provided internal Random functionality of Analyzing Scripts is not supported any more and is being replaced by the Analyzing Function Random now CHANGE Modified Width of Bars within the MTC yn T001 The visualized width of the displayed bars now can be chosen between thin 1 3 of the width for the bar 2 3 for the empty space moderate 2 3 of the width for the bar 1 3 for the empty space and thick full width for the bar no empty space CHANGE Renaming of the Plug In for the X Tools Client The plug in for the X Tools Client at the side of the X Tools Server has been renamed from DME DPM Client T001 dll to DME DPM X Tools Client T001 dl l CHANGE Reporting of invalid Indexes from ION ARCNET Spy T001 Devices In case an invalid index is being received from an ION ARCNET Spy T001 an according entry is being added to the system log now CHANGE Protection of currently used Configuration Files Via the X Tools Client it is not possible any more to rename del
170. ns of Monitoring Charts The context menus of the Pause and Continue buttons of all Monitoring Charts now always contain both the Pause Visualization and the Continue Visualization entries no matter whether the visualization is currently paused or not English Release 2014 11 25 81 CMS X Tools Change Log CMS FEATURE Improved System Log Viewer The improved System Log Viewer now allows to filter the present log entries and to search for texts within the present log entries In addition the scroll bar of the System Log Entries table allows to scroll arbitrarily through all log entries of the currently opened log file FEATURE Priority System for Log Entries The new priority System now is being assigned to all log entries which shall not be disengageable like the initial log entries that contain the version information or the log entries which report the resuming of a Configura tion File FEATURE Adding of more detailed System Information to the System Log Whenever the X Tools Client or the X Tools Server are being started detailed information about the current system is added to the beginning of the log file In addition whenever an X Tools Client connects to an X Tools Server detailed information about the system of the client is added to the log file of the server and de tailed information about the system of the server is added to the log file of the client FEATURE Adding of Versi
171. nt Multiple OPC UA servers can be accessed simultaneously and can be used in order to browse their address room to receive online data from them and to write their values FEATURE OPC UA Server X Tools now can act as OPC UA server Multiple OPC UA clients can connect to X Tools as OPC UA server and can browse the online data of X Tools as well as receive the values of the online data FEATURE Advanced Versioning of binary Files The format of the version for all binary files has been changed from V xx yy ll zzzz to V xx yy zz hh In former versions binary files were accepted only in case their complete version information xx yy ll and zzzz was identical to the main executable Now the last part of the version information hh can be different to the main executable which allows updating of single files e g in case of a hotfix FEATURE Screenshots The context menu of each Monitoring Chart now allows to print and to save a screenshot of the current visuali zation FEATURE Additional Monitoring Chart MTC Orbit T001 The new Monitoring Chart allows visualize orbits including Smax and Spp The visualized orbits can be calcu lated via the ANF Orbit FEATURE Additional Analyzing Function Orbit The additional Analyzing Function Orbit can be used in order to calculate the orbit Smax and Spp out of the provided x and y data FEATURE Additional Analyzing Function OutOrbit The additional Analyzing Functio
172. nt of the stop of the offline data file this probe may have been not added to the offline data file Instead the first probe after the stop time was added to the offline data file BUGFIX Missing first Probes within Offline Data Files In case there was a value with a timestamp at the moment of the start of the offline data file the first probe may have been not added to the offline data file BUGFIX Renaming of Categories within the MDX In case the name of a category should be renamed the number in brackets which contains the number of data below this category also could be edited BUGFIX Possibly improper Memory Calculations In case of PC configurations with more than 4 GByte of installed physical RAM the calculation of the memory which is available for the X Tools Server could be wrong In such a case the X Tools Server may have re fused to start additional Configuration Files although there would have been enough memory available BUGFIX Possibly not working loading of csv Files In case append or overwrite was called multiple times for the loading of csv files the second and all following calls could fail and did not find any csv files which could be loaded BUGFIX Possibly wrong Stop Time within the Header of exported CSV Files In case the Advanced Export dialog was used for the exporting of data the stop time within the header of the exported file could be wrong in case only a part of the available interval of the pres
173. o point being created for each turn of the mouse wheel CHANGE Alarm Interval of MonDisk Previously the alarm interval was counted from the start time of the Analyzing Model Analyzing Script Now the alarm interval counter starts at the time of the last log entry about a detected alarm CHANGE Review of the Icons of all Message Boxes Some message boxes within the system did not have the proper icons The icons of all present message boxes have been reviewed so that they contain the proper icons now CHANGE Review of all Log Entries The priorities of all log entries have been reviewed In addition some log entries have been modified in order to achieve a more common look of all log entries CHANGE Review of the Message Box about the opening of corrupted Configuration Files The message boxes which are being used by editors in order to notify a user that a corrupted Configuration File could not be opened have been changed to a more common look and feel CHANGE Review of the contents of the Tool Tip of the X Tools Server The information which is being displayed by the tool tip of the X Tools Server has been reviewed CHANGE The assigned Chart Name must be unique within one Monitoring View Monitoring Views do not allow any more to assign the same Chart Name to multiple of their Monitoring Charts The name of each Monitoring Chart must be unique within its Monitoring View CHANGE Empty Password Fields do not contain Stars
174. of lt Enter gt for the cell of the table BUGFIX Wrong handling of big Initialization Log Files In case the Initialization Log File become bigger than 1 MByte it could not be deleted any more As a result the X Tools Server was started in Safe Mode each time when the safe command line parameter was specified e g through the X Tools Service BUGFIX Wrong Resolution for the positioning of the Cursor Lines The calculation from timestamps to screen coordinates was different for measurement values and cursor lines In rare cases this rounding difference caused the cursor line to be shifted by one pixel against measurement values The same effect could cause that the cursor lines where shifted wrongly by half of a nanosecond BUGFIX Wrong counting of the undo redo Buffer within Monitoring Charts The actual undo redo buffer within Monitoring Charts always kept one entry less than specified For example in case an undo redo buffer size of 10 values was specified only 9 operations could be undone BUGFIX Wrong updating of the Column Width within the System Log Viewer In case the width of the System Log Viewer has been changed e g by showing hiding of the MMS Explorer or by a manual change of the width of the System Log Viewer the Entry column has changed its width automat ically In some cases it could happen that the scroll bar started to hide a small part of the other columns in which case the Entry column had to be resi
175. of Timestamp Errors In case multiple entries about timestamp errors are generated from a single timestamp client not more than one message of a type is being added to the system log within each 60 seconds CHANGE Improved Recovery from Timestamp Errors In case timestamp errors occur constantly the system automatically suspends and resumes all Device Profiles of IEEE1394 devices This attempt helps to recover from situations where the CPU usage comes close to 100 because a constant CPU usage of close to 100 makes it impossible for X Tools to calculate all timestamps properly CHANGE Separation between Timestamp Errors and lost IEEE1394 Packets In case the timestamp error between any two measurement packets is an integer multiple of the current sample rate the X Tools Server now detects that the cause must be a lost IEEE1394 packet Therefore this case does not cause log entries about timestamp errors any more CHANGE The Analyzing Function GenAlrmBnd is an advanced Analyzing Function The Analyzing Function GenAlrmBnd can be used only in by the Professional edition of X Tools not by the Standard and Demo editions CHANGE The Analyzing Function IRHPCH2 is an advanced Analyzing Function The Analyzing Function IIRHPCH2 can be used only in by the Professional edition of X Tools not by the Standard and Demo editions CHANGE The Index of the Analyzing Function Mux starts at 0 instead of 1 The index of the Analyzing Function
176. of offline data runs into an error e g there is a mismatch between the already loaded offline data and the content of a to be loaded offline data file the already loaded part of the offline data is added to the MDS Explorer FEATURE Improved System Information The log entries about the current system information of X Tools Client and X Tools Server have been im proved so that they now report also the computer name the maximal commit charge the currently used code page and the proper processor architecture FEATURE Global searching of References The Find References dialog can be used in order to find the specified data name within any of the currently present Configuration Files CHANGE New default Output Data Precision of Analyzing Models and Analyzing Scripts The default precision of the output Analyzing Functions of new Analyzing Models and Analyzing Scripts has been changed from Decimal64 to Decimal32 English Release 2014 11 62 81 CMS X Tools Change Log CMS CHANGE Improved handling of not supported Data Types through the SPE Binary T001 In case a data of not supported type e g a Spectrum is dropped onto a Storage ID Start Trigger Data Name or Stop Trigger Data Name cell an according message box is displayed which points out that the type of this data is not supported at this place CHANGE Improved handling of not supported Storage Modes through the SPM Binary T001 In case a not supported stora
177. of the information for a newly opened Monitoring View Now all parts of the Monitoring View are being displayed gradually and in parallel to the reception of all information BUGFIX X Tools Clients constantly can not connect to an X Tools Server There were different situations where an X Tools Server needed several seconds for the processing of an in coming connection from an X Tools Client In case this processing took too long for the X Tools Client it broke the connection and retried to connect This lead to an X Tools Server which was not accessible any more for any clients because it constantly was processing old connections without a chance to handle new ones BUGFIX Possible Crash when detaching of IEEE1394 Devices In rare cases there was a chance to end up with a crash in case a currently data streaming IEEE1394 device was detached BUGFIX Possible Crash when Closing of an X Tools Client In case multiple X Tools Clients were closed simultaneously there was a possibility that one of them crashed BUGFIX No Visualization of Data in case of low Access Rights In case the Visualization of additional Data access right of a user was set to Do not allow visualizing of addi tional Data there was a possible that this user also did not see any data from preconfigured Monitoring Views BUGFIX Some Orders of appending of Data caused improperly loaded offline Data Some orders of appending of offline data files could case improper
178. ofile can be used in order to write a string to a ini file Feature Additional Analyzing Function WriteValueToFile The new Analyzing Function WriteValueToFile can be used in order to write a value Boolean Integer or Dec imal to a ini file CHANGE Adding of ALM based License Management The Pro Edition of X Tools now is protected by the ALM Automation License Manager which allows to ena ble different functionalities depending to the available licenses English Release 2014 11 67 81 CMS X Tools Change Log CMS 2 10 X Tools V 04 01 gt X Tools V 04 02 IR1 The following changes have been introduced in X Tools V 04 02 IR1 FEATURE Support for direct Communication with CMS2000 Devices X Tools is able to communicate directly with CMS2000 devices and to receive their current measurement data as standard online data like it is known from all other supported devices FEATURE Increased maximal Number of Points In addition to the so far maximum of 65536 values also input buffers with 131072 and 262144 values are sup ported by the Analyzing Function FFT from now on FEATURE Optional saving of new Monitoring Views The new global option Prompt to save new Monitoring Views allows to choose whether the X Tools Client shall pop up with an according message when a new unsaved Monitoring View is going to be closed FEATURE Toolbar Button Print Screenshot for Monitoring Charts The additional toolbar butt
179. on Print Screenshot has been added to all Monitoring Charts FEATURE Variable Size of Toolbar Buttons The new global option Size of Toolbar Buttons allows to choose whether the toolbar buttons e g within Moni toring Charts shall be displayed with normal 100 or double 200 size FEATURE Showing and hiding of Toolbar Buttons The new context menu item Hide this Button can be used in order to hide any of the toolbar buttons of a Moni toring Chart In addition also the Chart Options dialog allows to show and hide single toolbar buttons now FEATURE Indication of a missing License In case the X Tools Server is started and it can not find a proper license the icons of the X Tools Server with in the X Tools Tray and within the Explorer trees of the X Tools Client display a warning FEATURE Optional Output of Log Entries to a csv File For support purposes it is possible to turn on a parallel output of all log entries into a csv file The contents of this csv file can be sorted and filtered by third party applications like Microsoft Excel FEATURE Configurable Size of Monitoring Charts within the MVE Standard T001 The new options Define available Width manually and Define available Height manually within the Monitor ing View Parameters table of the MVE Standard T001 can be used in order to choose the exact width and height that is used by the MVE Standard T001 in order to display the present Mon
180. on Information of the X Tools Client to the System Log During the startup of the X Tools Client detailed version information is being written to its system log FEATURE Copying of Data from one Loading Profile Editor to another Loading Profile Editor The data from the tables of a Loading Profile Editor now can be copied to the tables of another Loading Profile Editor FEATURE Copying of Data from Loading Profile Editors to Storage Profile Editor and vice versa The data from the tables of Loading Profile Editors now can be copied to the data table of Storage Profile Edi tors Consequently the data from the data table of Storage Profile Editors now can be copied to the tables of Loading Profile Editors as well FEATURE Copying of Definitions from one Interface Profile Editor to another Interface Profile Editor The definitions from one Interface Profile Editor now can be copied to another Interface Profile Editor of match ing type FEATURE Copying of Definitions from one Main Profile Editor to another Main Profile Editor The definitions from one Main Profile Editor now can be copied to another Main Profile Editor of matching type FEATURE Drag amp Drop of the Categories from the MDS Explorer In case a category is dragged from the MDS Explorer into another system all of the below data are being dropped into the target system now FEATURE Automatic stop of Configuration Files in case their Directory is being renamed or deleted In ca
181. onitoring Chart was configured to display the time on base of the local time zone of the server from which it gets the data the displayed time did not react in case the time zone at the source server had been changed Now the server notifies all connected clients in case its local time zone is being changed and the Monitoring Charts also start to use the new time zone immediately BUGFIX Startup Files are not being saved when it is not needed any more There was a possibility that the startup files of the system were written during the startup of the system although their content did not change BUGFIX Removing of unused Scroll Bars There was a possibility that the scroll bars stayed present within a workspace even in case all of the contained dialogs had been closed already BUGFIX Maximizing of the Main Window did not work when the Main Title Bar was hidden In case the main title bar was hidden double clicking onto the appearing main title bar did not maximize the main window BUGFIX InB1D did not accept input Data which did not contain some optional Contents InB1D now uses default values whenever an optional content of the input data is not present BUGFIX Restoring of the Size of the Log Viewer Window within the ODL Binary T001 Minimizing of the Log Entries table and restoring of it did not lead to the initial height of the Log Entries table again BUGFIX Shifting of Data in y Direction when the y Axes Area is hid
182. ons from the included Analyzing Scripts FEATURE Find and Replace within the ASE Standard T001 The ASE Standard T001 provides a Find and Replace dialog now which can be used in order to search texts within the Analyzing Script and or to replace a given text through some other text FEATURE Exporting of additional Information to csv Files In addition to the already exported information also the precision of the exported offline data is added to the header of each csv file now In case of extended data types like spectrum 1 dimensional buffer also the type and the format of the extended data type are exported FEATURE Group Boxes within the AME Standard T001 and UFE Standard T001 The AME Standard T001 and UFE Standard T001 now allow to add additional organization to Analyzing Mod els and User Functions So called group boxes can be put around the present Functions in order to highlight groups of functionality and to add additional descriptive comments FEATURE Undo and Redo within the AME Standard T001 UFE Standard T001 and ASE Standard T001 The AME Standard T001 UFE Standard T001 and ASE Standard T001 now provide undo and redo operations in order to undo redo the last inputs within their Analyzing Model User Function Analyzing Script FEATURE Additional Parameters for Analyzing Models Analyzing Models can be configured to take additional parameters when they are called via StartEx The addi tionally possible param
183. ontext menu item all log entries of the currently executed Analyzing Model or Ana lyzing Script still could re appear at the moment when the Analyzing Model or Analyzing Script was stopped BUGFIX Slow scrolling within big System Log Files The speed of the scrolling within the System Log Viewer via the lt Cursor up gt lt Cursor down gt lt Page up gt and lt Page down gt keyboard keys has been improved BUGFIX Missing Detection of Changes through the UFE Standard T001 The UFE Standard T001 did not detect that its currently opened User Function was changed in case an input or output interface was added or removed English Release 2014 11 48 81 CMS X Tools Change Log CMS BUGFIX Possible Corruption of User Functions In case an Analyzing Function which was connected to an output interface was removed from the User Func tion the whole User Function could become corrupted BUGFIX The Visualization within the MTC Orbit T001 might become smaller and smaller Whenever the size of the MTC Orbit T001 was changed the scaling of the contained orbit was recalculated and the displayed orbit became smaller and smaller BUGFIX Possibly slow Creation of new offline Data Files In case the memory usage through the X Tools Server was close to the maximal allowed value the creation of new offline data files through a Storage Profile could last very long e g more than 150 seconds for 1500 files BUGFIX Unwanted expand collapse aft
184. ontinue The internal status of the following Analyzing Functions now is being reset after their parent Analyzing Mod el Analyzing Script has been paused and continued again Buffer Delay GenerateWaveForm Histo gram1D Histogram2D Impulser Integral and Stopper CHANGE Behavior of the Analyzing Function Start In case the target Configuration File exists but is not in status started or stopped already Start creates an according log entry and does not attempt to start the Configuration File any more CHANGE Internal Precision of the Analyzing Function Modulo The internal precision of the Analyzing Function Modulo has been changed from Integer to Decimal64 CHANGE Ignoring of WM_TIMECHANGE after a Login via Remote Desktop In case a user logs in to a Windows 7 computer via Remote Desktop the WM_TIMECHANGE window message is sent to all running applications although no change of the time takes place In case this notification is re ceived X Tools restarts all of its measurement calculation and storing tasks In order to avoid the restart in this situation WM_TIMECHANGE is ignored in case it is received within 10 seconds after a user has logged in via Remote Desktop CHANGE Additional Precision for the Analyzing Functions ConvertValueToBuffer1 D and GetValue FromBuffer1D The Analyzing Functions ConvertValueToBuffer1D and GetValueFromBuffer1D now also provide Deci mal64 as supported
185. or the CTN WatchGuard T001 The X Tools Server now allows to switch the outputs of a CTN WatchGuard T001 each 10 ms now instead of 1 second like it was so far CHANGE Self Test at the Start Resume of Device Profiles for IFN Al Devices In case the Device Profile for an IFN Al is being started or resumed the executed self test performs the deter mination of the hardware offsets but does not check the status of the inputs cable break yes no any more English Release 2014 11 27 81 CMS X Tools Change Log CMS CHANGE Cyclic Self Test for IFN Al and IFN VIB A Devices In case the cyclic self test is being configured to Determine Hardware Offsets during the Measurement no check of the status of the inputs is being done any more CHANGE Updated IEEE1394 Device Driver The IEEE1394 device driver has been upgraded to V 3 0 9 4 CHANGE Maximal undo redo Buffer Size within Monitoring Charts The maximal undo redo buffer size within Monitoring Charts has been changed from 100 to 99 CHANGE Height of the Data Table within the SPE Binary T001 The height of the Data table now is always an integer multiple of the height of one row In addition the height of the Data table now is not bigger than the visible height of the SPE Binary T001 itself CHANGE Improved undo redo for Mouse Wheel Operations within Monitoring Charts Previously each mouse wheel event created its own undo redo point Now there is only one undo red
186. orking memory after the Analyzing Model or Analyzing Script had been started BUGFIX Set to Default Context Menu within the Analyzing Function Properties Dialog The Set to Default context menu now is available also for record parameters edit boxes and buffer parameters edit boxes BUGFIX Possible Crash in case multiple X Tools Clients are being started simultaneously In case multiple X Tools Clients were started simultaneously there was a chance to receive a crash of several of the starting X Tools Clients In addition there was also a possibility to end up in a crash of the X Tools Server under certain conditions BUGFIX Possible Crash in case multiple X Tools Clients are being closed simultaneously In case multiple X Tools Clients were started from the same directory and closed simultaneously afterwards there was a chance to receive a crash of several of the closing X Tools Clients BUGFIX Possible Hang of the X Tools Client in combination with frequent Outputs to the System Log Some Analyzing Models and Analyzing Scripts are able to produce a large number of outputs to the system log In case the log entries of an Analyzing Model or Analyzing Script were output directly within the AME Standard T001 or ASE Standard T001 a significant slowdown could be observed over a time which also could look like a hang after a while BUGFIX Possibility of too late closing of opened Sockets There were several cases in which the
187. other within very little time it could happen that no more notifications about data values were sent at all From the point of view of the application which used the XSI it looked like the data streaming was stopped English Release 2014 11 47 81 CMS X Tools Change Log CMS BUGFIX Possible Crash within the DPE ION SIMATIC TDC T001 In case the information about the address book of the ION SIMATIC TDC T001 was not consistent there was a possibility to end up in a crash of the X Tools Client BUGFIX Corruption of User Function Files through the UFE Standard T001 In case the Analyzing Function which was assigned to the first output of the User Function was deleted the internal state of the complete User Function could become corrupted and the User Function became unusable BUGFIX Possible Log Entry Flood in case the Hard Disk is full In case the hard disk to which the log file is being written became full a lot of log entries about lost log entries could appear within the System Log Viewer of a connected X Tools Client BUGFIX Unwanted copy of Configuration Files In case a Configuration File was dragged with the mouse and dropped onto its own parent directory a copy of the dragged Configured File was created Now an according error message is displayed instead of the copy BUGFIX Wrong Log Entries during the suspend and resume of Analyzing Models Analyzing Scripts In case an Analyzing Model or an Analyzing Script was suspended the
188. ould return and the following access to the not finished data could lead to a crash of the X Tools Server English Release 2014 11 59 81 CMS X Tools Change Log CMS BUGFIX Timeout during the reading of an Address Book from an ION SIMATIC TDC T001 In case a packet with address book information from the ION SIMATIC TDC T001 to the X Tools Server con tained exactly 1464 bytes of data a timeout could be detected by X Tools because of a wrong internal check BUGFIX Possible Crash because of improper Access to Data within the Storage System A certain timing could cause a crash of the X Tools Server at a moment when a Storage Profile with a manual start stop trigger performed checks about a theoretic data start stop trigger These checks have been removed BUGFIX Possible Crash of the X Tools Client after the shut down of the X Tools Server In case a context menu for the X Tools Server was called before the shut down of the X Tools Server within any explorer tree of the X Tools Client and a context menu item was chosen after the shut down a crash of the X Tools Client could occur BUGFIX Wrong Information about Analyzing Functions with configurable Arguments The Analyzing Function Properties dialog could display wrong information about Analyzing Functions which provide a configurable number of input or output arguments in case some of the arguments of the Analyzing Function were used as parameter of the Analyzing Model BUGFIX No A
189. ount of time FEATURE Additional Analyzing Function StartEx The new Analyzing Function StartEx can be used in order to start an Analyzing Model with passing of parame ters to it FEATURE Additional Analyzing Function AddB2D The new Analyzing Function AddB2D can be used in order to add the amplitudes of two 2 dimensional buffers FEATURE Additional Analyzing Function Extrapolate The new Analyzing Function Extrapolate can be used in order to extrapolate the trend from a given time series into the future FEATURE Additional Analyzing Function GetStatus The new Analyzing Function GetStatus can be used in order to determine the status e g data is valid input not available or division by zero which belongs to each link like the value which is transported FEATURE Additional Analyzing Function RemCnt The new Analyzing Function RemCnt can be used in order to use a remanent counter within Analyzing Models and Analyzing Scripts The value of this counter is read from and written to a ini file which is put into the direc toy of the parent Analyzing Model Analyzing Script therefore it also stays remembered between restarts of the Analyzing Model Analyzing Script and of X Tools itself FEATURE Additional Output Mode Single Value for Output Analyzing Functions The additional output mode Single Value can be used in order to create offline data with exactly one probe timestamp val
190. ows to use the complete functionality of frequency markers not only for frequency spectrums but also for order spectrums FEATURE Go to Parameter Context Menu Item within the AME Standard T001 In case an input argument of an Analyzing User Function or any other setting of an Analyzing Model has been added as parameter of the Analyzing Model the Go to Parameter context menu item can be called in order to highlight the entry of the Provided Parameters table which belongs to this input argument setting English Release 2014 11 68 81 CMS X Tools Change Log CMS FEATURE Go to Input Interface Context Menu Item within the UFE Standard T001 In case an input argument of an Analyzing User Function has been added as input interface of the User Func tion the Go to Input Interface context menu item can be called in order to highlight the entry of the Provided Input Interfaces table which belongs to this input argument FEATURE Go to Output Interface Context Menu Item within the UFE Standard T001 In case an output argument of an Analyzing User Function has been added as output interface of the User Function the Go to Output Interface context menu item can be called in order to highlight the entry of the Provided Output Interfaces table which belongs to this output argument FEATURE Additional Analyzing Function TestEntryFromFile The new Analyzing Function TestEntryFromFile can be used
191. r could end up in a deadlock and a following crash BUGFIX Missing Update of the Example Row within the Data Style Dialog of Monitoring Charts After pressing of the Apply button the preview within the example row was not updated BUGFIX Possible Log Spam in case of missing Licenses for SIMATIC Devices In case a Device Profile for a SIMATIC device was started and no license was available the Device Profile sus pended and attempted to resume each 10 seconds where each attempt to resume caused another log entry Now the Device Profile suspends and does not resume until the Device Profile File is changed BUGFIX Correcting of Analyzing Scripts from the Example Location The following Analyzing Scripts from the example location caused constant log entries about too small ring buff er sizes when they were started ConvVToB1D 01 GenAlrmBnd 01 GetBffrM 01 H2D 01 and Rsmpl 01 BUGFIX Correcting of Analyzing Scripts from the Example Location The Analyzing Script Mux 01 from the example location was unable to run properly and suspended immediate ly when it was started BUGFIX Correcting of Analyzing Models and Analyzing Scripts from the Example Location The Analyzing Model TLC 02 and the Analyzing Script TLC 02 from the example location did not output any value BUGFIX Wrong Begin Time within the Header of exported CSV Data The begin time within the header of exported csv files could be point to a point in
192. r log entry is created instead BUGFIX Wrong Behavior of paused Interface Profiles Paused Interface Profiles of type Socket T001 or Serial Port T001 did not behave correctly Now devices are not being disconnected at the moment of pausing of their Interface Profile and while the Interface Profile is paused no new connections to devices are being established BUGFIX Device Profiles for OPC UA Devices don t work without a configured Input Data Device Profiles for OPC UA devices could not be started in case they did not contain any configured input data Now it is possible also to create Device Profiles which contain only output data BUGFIX Suspended Device Profiles of Software I O Nodes after a Change of the System Time In case Software l O Nodes e g ION SIMATIC S7 PN were attached to X Tools and streaming data at the moment of a change of the system time it could happen that the according Device Profiles suspended and did not resume ever BUGFIX Missing Start Value in case of the Analyzing Function Out with a setting of Changes Only In case the value of Record Mode was configured to Changes only the first value was not output In case all values after the first one have the same value no data values were output at all BUGFIX Resurrection of Log Entries In case the contents of the Log Entries table within an AME Standard T001 or ASE Standard T001 were cleared via the Clear Log c
193. re than one X Tools Server starting of a formula via the For mula Editor table of a MVE Standard T001 did not work properly The status within the Formula Editor table was not updated and the output data could not be removed from the system any more BUGFIX Possible Corruption of a User Function Removing of an Analyzing Function which provided input and or output arguments of the User Function could corrupt the User Function BUGFIX Removing of Manual scale Renderer from the MTC Vector2D T001 The context menu item Manual scale Renderer has been removed from the MTC Vector2D T001 because the configuration of the renderer is not supported by this Monitoring Chart BUGFIX Exit did not allow to exit during the first Cycle In case Exit tried to exit during the first cycle of an Analyzing Model Analyzing Script it output a wrong log entry and suspended the parent Analyzing Model Analyzing Script afterwards BUGFIX Possibly missing Line within the MTC yt T001 In case the t axis of the MTC yt T001 had to show a very long time interval tens of years the line of the visual ization could start in the middle of the Monitoring Chart instead of at the left of the Monitoring Chart BUGFIX Possible Crash in case OutSclrSir had to output an empty String In case an empty string was passed to the Analyzing Function OutSclrStr it could cause a crash BUGFIX Wrong handling of negative Timestamps through H2D The
194. rer In case a search was performed via the MDS Explorer when it contained hundreds or thousands of data the MDS Explorer could start to scroll for a long time first and the X Tools Client could end up with a hang after wards BUGFIX Visualization Artifacts within the MTC ynt T001 Some combinations of y axis and t axis scaling could create visualization artifacts in form of filled rectangles which have pointed to the center of the bottom of the cuboid BUGFIX Wrong handling of Record Modes through the Analyzing Function OutStr The output string contained random characters in case the chosen record mode was Changes only or Changes and Interval BUGFIX Possible Crash during the simultaneous Start of multiple Monitoring Views In case multiple Monitoring Views were started via a start of their parent directory the X Tools Server could end up in a crash BUGFIX Wrong Output of the Analyzing Function OutSir in combination with Record Modes In case the record modes Interval Only or Changes and Interval were used in combination with the Analyzing Function OutStr the output string values were wrong BUGFIX Possible Hang of Storage Profiles after a Change of the System Time A change of the system time could cause a hang of Storage Profiles In this situation the Storage Profile re mained in status stopping forever BUGFIX Monitoring Charts do not remember the Chart Background which was set as Standard
195. runcated to 8 bits In case longer bit arrays were to be im ported their values were lost BUGFIX Bit Arrays could not be deleted after the Import After importing of bit arrays into a Device Profile the according data definitions could not be deleted in some cases English Release 2014 11 19 81 CMS X Tools Change Log CMS BUGFIX Possible failed resume of a Device Profile right after the attach of its IEEE1394 Target Device Under certain conditions the system was unable to resume a Device Profile right after the attach of its IEEE1394 target device In such a case the resume always took place a few seconds later BUGFIX Missing Events in case of Suspend Resume of Device Profiles The data available start stop events were not added to the data of Device Profiles in case the Device Profile was suspended resumed As a result event using functionalities did not behave correctly in such situations e g Analyzing Models Scripts did not suspend resume properly when their input data from Device Profiles disap peared or re appeared BUGFIX Very fast suspend resume of Analyzing Models Scripts could freeze the X Tools Client In case there was an Analyzing Model Script which suspended and resumed very frequently the X Tools Client could be frozen After a while in this condition even a crash was possible BUGFIX Slow opening of a lot of Data from a remote Server within the Monitoring System Opening of data from a remote server which is
196. s table could be wrong or N A BUGFIX Exporting of Data did not work for Categories of the MDS Explorer In case Export or Advanced Export was chosen from the context menu of an offline data category of the MDS Explorer the Export Progress dialog got displayed but nothing else happened BUGFIX Missing Hotfix Information about DME EIM OPC UA Server T001 dll The X Tools Server did not create a log entry in case a hotfixed version of DME EIM OPC UA Server T001 dll was installed BUGFIX Wrong Time Base within the Tooltip of Monitoring Chart Sliders The sliders at the top of Monitoring Charts did not use their current time base for the times which were dis played within their tooltips BUGFIX Forgotten Display Time Update Setting within the MTC yx T001 The MTC yx T001 did not remember the configured settings for Update Display Time after Open and Update Display Time after Action BUGFIX Delayed Takeover of the Scaling Interval Settings within the MTC yt T001 The MTC yt T001 did not take over changed values of the Auto set Scaling Interval and Scaling Interval set tings after OK or Apply had been pressed within the Manual scale t Axis dialog Instead it was necessary to move the t axis after such a changed value in order to take over the new setting BUGFIX Unwanted Mixup of offline Data with absolute and relative Timestamps The MTC yt T001 was able to show the tim
197. s e g crashes All other startup types could not monitor the X Tools Server Now the Automated Startup entry does not influence the monitoring of the X Tools Server and the Automated Restart entry from the global options can be used instead in order to turn the monitoring on or off for any of the available startup types CHANGE Changed Scaling of Axis The scaling of axis has been changed Now the axis always displays the full value up to a certain amount of digits and the axis also displays the exponent directly The legend does not contain information about the scal ing any more and a tool tip is available which shows the full number of each entry of the axis English Release 2014 11 28 81 CMS X Tools Change Log CMS CHANGE Faster saving of new Files Whenever the Save As dialog is being opened the input focus is being set to the file name entry automatically and the user can start to enter the new file name directly CHANGE Keyboard Shortcuts for all Monitoring Charts The keyboard shortcuts of all Monitoring Charts have been reviewed so that now the behavior of all Monitoring Charts is more common Compared to previous versions there are more keyboard shortcuts available now CHANGE Greeting Message to SMTP Servers In case a username and password is specified for the connection to a SMTP server for sending of emails the EHLO welcome message is being used now instead of the HELO welcome message CH
198. s Servers FEATURE Detection of not synchronized System Times of Socket Devices In case two or more socket devices e g ION SIMATIC S7 PN ION SIMATIC TDC T001 are configured to share the same time domain the X Tools Server outputs a log entry in case it finds out that the system times of these devices are too far away from each other In this situation the time domain setting within X Tools must be changed or the system time synchronization of these devices must be added improved FEATURE Increased Address Room for the X Tools Server The X Tools Server now supports the IMAGE_FILE_LARGE_ADDRESS_AWARE flag This allows to use more memory in environments which have more then 2 GByte of working memory available See the user man ual for detailed information about how to gain more than 2 GByte of RAM for the X Tools Server FEATURE Zooming within the AME Standard T001 and UFE Standard T001 The currently opened Analyzing Model or User Function now can be zoomed within the AME Standard T001 and UFE Standard T001 This allows to keep a better overview also in case of larger Analyzing Models or User Functions FEATURE Special Syntax for the local Configuration File Location Control Analyzing Functions like Start Stop MonCF now can use a location name of when they shall refer to a Configuration File which is located within the same location as the parent Analyzing Script of the Analyzing Function This allows to cre
199. s a value at exactly the stop time of an offline data file no following probe is inserted into the offline data file any more CHANGE Default Target for opening of System Log Files In case All is being chosen as Source Name within the System Log Settings table of the System Log Viewer and the Oper button is being pressed the default Target Name is being set to Local Client now CHANGE Dropping of Analyzing Models Analyzing Scripts into non empty Editors In case an Analyzing Model Analyzing Script is being dropped into a non empty Analyzing Model Edi tor Analyzing Script Editor these editors now behave identical to the other editors of X Tools and allow to choose whether the previous file shall be saved or overwritten or whether a new editor shall be opened for the dropped Analyzing Model Analyzing Script CHANGE Messages within Device Profile Editors Several messages and icons of messages which occur during the editing of the Message Channel Contents table have been improved CHANGE Communication to the ION SIMATIC TDC T001 Old versions of the ION SIMATIC TDC T001 versions older than V 03 01 did not support the full command set which is being used by X Tools for the communication with the device X Tools does not support these older versions of the ION SIMATIC TDC T001 any more CHANGE System Log Entries for connecting Disconnecting of Socket Devices The system log entries which appear during the start stop of a
200. s the input focus and lt F5 gt is being pressed the information about the contents of the tree are being re read FEATURE The Address Book of ION SIMATIC TDC T001 can be stored to any Location In case a tree has the input focus and lt F5 gt is being pressed the information about the contents of the tree are being re read FEATURE Support of SIPLUS CMS4000 IFN ANALOGINPUT Support for the new hardware interface node IFN ANALOGINPUT FEATURE Support of SIPLUS CMS4000 IFN VIB ACC Support for the new hardware interface node IFN VIB ACC FEATURE No Message for unchanged Configuration Files In case a new Configuration File is being initialized by an editor and the editor is being closed afterwards without any modification to the Configuration File there is no more message which asks whether to save the Configura tion File FEATURE Automatic Takeover of changed Configuration Files The X Tools Server can be configured to automatically take over a Configuration File which has been changed at the disk In case this setting is active saving of a Configuration File either via X Tools or via the Windows English Release 2014 11 10 81 CMS X Tools Change Log CMS Explorer automatically restarts its execution on base of the new contents of the Configuration File in case the Configuration File was started already FEATURE Identification of the X Tools Server also via its Computer Name In addition to an IP address also a computer
201. s which produce offline data can be switched between append and overwrite now overwrite behaves like in previous versions and over writes already existing offline data with the results from the new calculation whereas append adds the results from the new calculation to the already existing offline data FEATURE Improved automatic Update of Analyzing Models and User Functions Previous versions of X Tools were not able to update Analyzing Models and User Functions automatically in some cases when the new versions of the to be updated Functions were bigger than the currently used ver sions Now all Functions which are below or right to the to be updated Functions are moved to the bottom and or to the right in case this is necessary FEATURE Searching within the MDS Explorer A search functionality now allows to search for online data online data categories offline data and offline data categories within the MDS Explorer FEATURE Searching within the ANS Explorer A search functionality now allows to search for Analyzing Functions and User Functions within the ANS Explor er FEATURE Additional Configuration for Notifications via Email The new global option Notification from the Improved Availability group of the X Tools Server can be used in order to configure whether the X Tools Server shall attempt to send an email notification during the first restart after an abnormal termination FEATURE Propag
202. s with multiple Firmware Versions In case of devices with multiple firmware versions both firmware versions are being written to the System Log at the moment of the connect CHANGE Message Box for the MTS in case of zooming when the Ring Buffer is not available any more During the visualization of data it always can happen that the data source disappears e g the source device is being detached At this moment also the ring buffer of the data is being removed In case the user pauses the visualization of some data after its ring buffer has been removed and zooms into this data a message box pops up and informs the user about the non availability of the detailed information CHANGE Moving to the latest Redistributable Files The latest version of the redistributable files from Microsoft have been added to the release version CHANGE Handling of empty Analyzing Models Scripts In case an empty Analyzing Model or an empty Analyzing Script is being started it suspends immediately and does not resume until its file at the disk is being updated CHANGE Introduction of the License Management The different editions of X Tools e g Standard or Professional now can be accessed by using of different li censes CHANGE Separation into basic and advanced Analyzing Functions The Analyzing Functions which are being delivered together with X Tools are separated into basic and ad vanced Analyzing Functions now where the according license is need
203. se a directory for Configuration Files is being renamed or deleted all of the contained Configuration Files are being stopped now FEATURE Automatic stop of Configuration Files in case their Location is being removed or deleted In case a location for Configuration Files is being removed or deleted all of the contained Configuration Files are being stopped now The startup files are not being changed by this operation thus all of the Configuration Files which were running at the moment of the remove would be started automatically in case the location would be added again FEATURE Automatic start of Configuration Files in case their Location is being added In case a location for Configuration Files is being added the startup files of the location are being processed and all of the according Configuration Files are being started automatically FEATURE Naming of Sliders Within Monitoring Charts the name of each slider now is displayed at the left side of the slider The name of a slider is used in order to identify it e g within the Manual scale Renderer dialog FEATURE Clearing of the Undo Redo Buffers of Monitoring Charts The current contents of the undo and redo buffers of all Monitoring Charts can be cleared via the context menu of the Undo Redo buttons now FEATURE Setting of the Undo Redo Buffer Size of Monitoring Charts The size of the undo and redo buffers of Monitoring Charts can be changed via the context menu of the U
204. so the COM ports above 9 can be used by the X Tools Server CHANGE Additional Status Information for ION PROFIBUS DP T001 Devices Additional status information is output now at each stop of the ION PROFIBUS DP T001 device The additional status information provides more details about the exact reason of the current stop CHANGE Initial Buffer Size of new Device Profiles for Software I O Nodes In case a new Device Profile for a software I O Node is being created and the initial buffer size can not be read from the target device the initial buffer size is being set to the maximal allowed buffer size CHANGE Allowed Range within the Manual scale y Axis Dialog The allowed range for the scaling of y axis has been changed in order to fit the different precisions and depend encies to exponents better CHANGE Only absolute Values for Frequencies The cursor table of the MTC yt T001 displays the calculated frequencies always as absolute value now also in case T2 T1 is a negative value CHANGE Default Width of the Columns of the Cursor Table In case the cursor table is being opened the width of its columns is adjusted automatically so that all contents of all columns are fully visible CHANGE Higher Granularity of the Timestamps from IEEE1394 Devices The timestamps of all IEEE1394 devices were rounded to full us so far Now also ns between 0 999 can be part of these timestamps CHANGE Additional Version Information for Device
205. sockets of a client lt gt server connection were not closed properly after the disconnect As a result these sockets stayed present within the system and could reduce the amount of available socket resources BUGFIX Possibility of a Deadlock during the closing of the X Tools Server In case multiple X Tools Clients were connected to one X Tools Server simultaneously and the X Tools Server was closed there was a possibility of a deadlock within the X Tools Server which prevented it from a clean shutdown BUGFIX Too long shutdown of the X Tools Client in case of a lot configured target X Tools Servers In case a lot X Tools Servers were configured within the currently started Main Profile the shutdown of the X Tools Client could last several tens of seconds independently to whether the connections actually could be established or not BUGFIX Too many copied Data Styles In case the data styles were copied from one data to another data the target data got all styles from the source data Instead the styles which are Default for the source data now stay also Default for the target data thus the copying of data styles can be used in order to selectively copy the styles of interest only BUGFIX Wrong Caption of the Manual scale y Axis Dialog of binary Axes The caption of the Manual scale y Axis dialog for binary y axes has been corrected BUGFIX Missing and wrong Context Menu within the Advanced Store Export
206. stead the AME Standard T001 and the UFE Standard T001 continue to updated all other functions CHANGE Remembering of the last used Target Name through the System Log Viewer The System Log Viewer now remembers the last used Target Name whenever it is closed In case it is opened via the System Log Viewer button from the menu bar of the Main Management System afterwards it automati cally connects to the last used Target Name again CHANGE Adding of the Restore Defaults Button to the Select Style Dialog The Restore Defaults button now is available to the Select Style dialogs of all Monitoring Charts and allows to set all settings back to the values which are delivered together with X Tools CHANGE The Index of the Analyzing Function DeMux starts at 0 instead of 1 The index of the Analyzing Function DeMux now starts with O instead of 1 CHANGE Stopping of Monitoring Views and Storage Profiles which operate on offline Data Whenever a Monitoring View or a Storage Profile which uses offline data as input would have to suspend be cause of any reason the according Monitoring View or Storage Profile now suspends BUGFIX Possible Crash in Case exactly 16 Alarm Band Inputs were used for MonAlrmSpm An improper memory allocation could cause a crash in cases where all 16 alarm band inputs were used BUGFIX Wrong Index Generation in case of the Precision Boolean within GetVFrmB1D In case the precision
207. t any more in case the only available information is N A CHANGE Updating of the DMS Explorer via lt F5 gt In case lt F5 gt is being pressed within the DMS Explorer also the list of currently connected devices is updated now Previously the update covered only the present files CHANGE Usage of the low Fragmentation Heap The X Tools Server now uses the low fragmentation heap for all memory allocations In case of applications with frequent allocation and freeing of memory e g storing of fast data pause continue within Monitoring Views or frequent start stop of Configuration Files the low fragmentation heap allows to run the application longer without running into low memory conditions because of memory fragmentation CHANGE Improved Speed for the loading of offline Data The loading of offline data files has been speed up several times CHANGE lt Cursor up gt within Combo Boxes In case the lt Cursor up gt keyboard key is being pressed while the topmost entry of the combo box is selected the combo box is not being left any more BUGFIX Memory Leak when opening of Analyzing Models During the opening of Analyzing Models there was a possibility for a memory leak In this case the allocated resources were not freed at the closing of the Analyzing Model BUGFIX Possible Crash in case there were no GDI Resources available In case the X Tools Client could not allocate needed GDI resources there was a possibility to
208. t lt C gt and pasted afterwards BUGFIX Possible Crash when copying of Configuration Files between X Tools Servers A crash could occur in case the source server from which the Configuration File shall be copied disappeared before the paste operation was started BUGFIX Possible Inconsistencies within User Functions The content of User Functions could become inconsistent in case the number of configurable arguments of a contained Analyzing Function was changed As a result the X Tools Client could crash at the moment of sav ing or the assignment of the inputs and outputs of the User Function could become wrong BUGFIX Frequent saving of the Contents of the Global Options Editor could clear the Entries of Combo Boxes In case the contents of the Global Options Editor were saved frequently the combo boxes could become empty after a while BUGFIX Possible Corruption of a User Function File In case the first output interface of a User Function File was deleted the User Function File could be corrupted 2 5 X Tools V 03 04 gt X Tools V 03 05 The following changes have been introduced in X Tools V 03 05 FEATURE Additional Analyzing Function ClcXYEnv The new Analyzing Function ClcXYEnv can be used in order to calculate envelopes for x y data FEATURE Additional Analyzing Function MonXYEnv The new Analyzing Function MonXYEnv can be used in order to monitor whether the values of the current x y input data are within th
209. t started to create hundreds of log entries about wrong resume attempts which instantly ended in another suspend BUGFIX Possibly wrong Values within the MTC ynt T001 The MTC ynt T001 could display wrong information about amplitudes with a value of O BUGFIX Possible Time Shift between the Values from two Devices with the same Time Domain In case two or more socket devices have shared the same time domain the calculated timestamps could differ by a static offset even in case both devices delivered identical relative timestamps BUGFIX Wrong Scaling and or Unit within the MTC yn T001 In case a frequency spectrum with maximal frequencies of several kHz was dropped so that a new MTC yn T001 was created the value and unit which were displayed at the very right of the x axis could be wrong BUGFIX Possible Stack Overflow within Analyzing Scripts because of implicit Scalar Data Outputs In case an implicit scalar data output like s Test 1 was used within a sequential Analyzing Script a stack overflow could occur after about 100 calls to this output BUGFIX Wrong initial Value from the Analyzing Function H2D The Analyzing Function H2D could output a value at the moment of its first call after the start of the Analyzing Model Analyzing Script This was wrong because at this moment the Analyzing Function could not have col lected the necessary input data BUGFIX The Analyzing Function OR did not support Links to non Boolea
210. t was possible to end up with a crash in case the Time Domain parameter from the Monitoring View Parame ters table was changed while the data of one or multiple MTCs was not available BUGFIX Deleting of a Location may not delete the Root Directory When a location was deleted it could happen that the empty root directory of the location remained present BUGFIX Possibly missing Values in case of Action based Analyzing Models and Analyzing Scripts Action based Analyzing Models and Analyzing Scripts could oversee values at the beginning of the processing in case there was no value at the exact moment of the start time of the Analyzing Model Analyzing Script BUGFIX Missing Log Entries about Locations which become available or unavailable There were no log entries at the moments when an already present location became unavailable and in case a currently unavailable location became available again BUGFIX Possibility to choose a wrong Server for the Selection of a to be used Loading Profile The ODL Standard T001 allowed to choose the Loading Profile from another X Tools Server via its Advanced Append Advanced Overwrite and Advanced Export dialogs This is wrong because the Loading Profile from another X Tools Server is not available during the actual append overwrite or export operation BUGFIX Too early Resume Suspended Monitoring Views Analyzing Models Analyzing Scripts and Storage Profiles attempted to resume too early in
211. tForCF now also accept Monitoring Views as input argument CHANGE Modification of the openMVE Command Line Parameter In case there is an X Tools Client running already the specified Monitoring View is opened within this X Tools Client All eventually already opened Monitoring Views which are not specified via openMVF are closed auto matically CHANGE Removing of the Support for Devices The following devices are not supported by X Tools any more ION ARCNET Spy T001 ION CS31 Spy T001 ION PROFIBUS DP T001 and ION SIMOLINK T001 CHANGE Naming of X Tools X Tools has been renamed from SIPLUS CMS4000 X Tools to SIPLUS CMS X Tools CHANGE Removing of the File Skin skn xtc The file which contained the skinning information for the X Tools Client has been removed The according in formation has been moved to the resources of X Tools Client exe CHANGE Stop of the Data Streaming at the Moment of pausing of a Device Profile When a Device Profile is paused the data streaming from the device to the X Tools Server is stopped now in order to reduce the CPU usage through the X Tools Server When the Device Profile is continued the data streaming is restarted CHANGE New Spacing within Standard Dialogs The spacing between controls has been reduced within the Loading Progress Export Progress and Storage Progress dialogs in order to provide a more compact appearing In addition also the spacing of all
212. ta became unavaila ble BUGFIX Time Wrap of ION SIMATIC S7 300 T001 ION SIMATIC S7 400 T001 ION SIMATIC S7 400 T002 and ION SIMOTION T001 Devices The time wrap value of the above devices has been changed from 4 294 967 296 to 3 600 000 000us BUGFIX Unwanted Change of the Format of Date and Time Cells After editing of the date or time of start or stop triggers within the Storage Profile Editor the format of the dis played date or time has been changed automatically to the formatting which was specified via the Control Panel of Windows Now X Tools always uses its own format for these dates and times BUGFIX Ignored Number of Digits after the Decimal Separator within the Loading Profile Editor The Time Interval cell of the Included Data Table of the Loading Profile Editor did not take over the number of digits after the decimal separator which has been specified via the Global Options Editor BUGFIX No Possibility to change the Password of the Administrator The password for the built in user account Administrator could not be modified by the user BUGFIX Forgotten Mark Types within Monitoring Charts Under rare conditions the Data Style dialog of Monitoring Charts has reset a previously configured mark type English Release 2014 11 8 81 CMS X Tools Change Log CMS BUGFIX X Tools did not start in combination with some Time Zone Settings In case the used operating system was configured to a time zone which does not kno
213. tion Only qualified personnel should be allowed to install and work on the equipment Qualified persons are defined as persons who are authorized to commission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning only in connection with devices or components from other manufacturers approved or recommended by Siemens This prod uct can only function correctly and safely if it is transported stored set up and installed correctly and operated and main tained as recommended A This device and its components may only be used for the applications described in the catalog or technical description and Trademarks All designations marked with are registered trademarks of Siemens AG Other designations in this documentation might be trademarks which if used by third parties for their purposes might infringe upon the rights of the proprietors Copyright Siemens AG 2014 All rights reserved Reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Disclaimer of Liability We have checked the contents of this document for agreement with the hardware and software described Since deviations cannot be precluded en
214. tion Cepstrum The additional Analyzing Function Cepstrum calculate the cepstrum of the online or offline input buffer FEATURE Additional Analyzing Function EnvelopeHilbert The additional Analyzing Function EnvelopeHilbert calculates the envelope of the online or offline input signals by using the Hilbert transformation FEATURE Additional Analyzing Function SelectiveRootMeanSquare The additional Analyzing Function SelectiveRootMeanSquare calculates the root mean square for the speci fied frequency range of the online or offline input spectrum FEATURE Additional Analyzing Function TotalHarmonicDistortion The additional Analyzing Function TotalHarmonicDistortion calculates the total harmonic distortion of the online or offline input signals FEATURE Additional Analyzing Function Crest The additional Analyzing Function Crest calculates the crest factor of the online or offline input signals FEATURE Additional Analyzing Function GetPeriod The additional Analyzing Function GetPeriod calculates the period of the online or offline input signals FEATURE Additional Analyzing Function Histogram2D The additional Analyzing Function Histogram2D creates the 2 dimensional histogram of the online or offline input signals FEATURE Additional Analyzing Function Kurtosis The additional Analyzing Function Kurtosis calculates the kurtosis of the online or offline input signals based on the Fischer s definition
215. tions could become corrupted BUGFIX Possible Crash in case of Conversions to Integer Data Types In case implicit outputs from Analyzing Scripts were used in order to output data of type Integer a crash could in cases where the input data had non zero digits after the comma BUGFIX Possible Hang of Monitoring Views A certain timing could lead to a deadlock and as a result to a hang of a Monitoring View during its attempt to resume BUGFIX Possible temporary Freeze of the X Tools Client The X Tools Client could temporarily freeze for seconds up to minutes in case of systems with a lot of ongo ing state changes of Configuration Files e g from started to stopped or vice versa BUGFIX Wrong handling of the Interpolation Mode None through the Analyzing Function InB2D In case the Analyzing Function InB2D was called with an interpolation mode of None it did not set the status of its OutputO properly As a result following Analyzing Functions could use wrong values for their calculations English Release 2014 11 56 81 CMS X Tools Change Log CMS 2 7 X Tools V 04 00 IR1 gt X Tools V 04 00 IR2 The following changes have been introduced in X Tools V 04 00 IR2 FEATURE Offline Data Viewer Edition of X Tools This new edition is provided in addition to the Professional edition of X Tools from now on It can be started in parallel to a Professional edition and allows to perform b
216. tirely we cannot guarantee full agreement However the data in the manual are reviewed regularly and any necessary cor rections will be included in subsequent editions Suggestions for improvement are welcomed Siemens AG Industry Sector P O Box 4848 90327 Nuremberg Siemens AG 2014 Germany Technical data subject to change English Release 2014 11 2 81 CMS X Tools Change Log CMS Table of Contents 1 Pri a a dario 4 1 1 Purpose of this DOCU ld 4 1 2 Validity of this Docume isese A A 4 1 3 AUGIONCS moonen e a a eevee te ee 4 2 Change LOs aatia e A A eee AEN Mee AER ER eee bh ed a a a e oi 5 2 1 X Tools V 03 00 gt X Tools V 03 014 oocconoccccnonoccconanoncncnnnoncnnnnno an aani a a aa 5 2 2 X Tools V 03 01 gt X TOOIS V 03 02 cooocccoonoccccconocccccononcncnnnoncncnnnoncncnnnnnnnnnnnn acc r cnn nr nr EARE RA 10 2 3 X Tools V 03 02 gt X Tools V 03 08 arpide rei iagen etara ee eet ein ee eee En KAA ARENIS TAER ka FA RAF IAA AEREE CALEN ETGEN 24 2 4 Po A A E o E EO P T E E A T E EE 36 2 5 X Tools V 03 04 gt X Tools V 03 05 onerarias diekin a a 42 2 6 X Tools V 03 05 gt X Tools V 04 00 IR1 eee eececeeeeeceeeeeeeneeeeeeaeeeee teases eeeaaeeeeeeaeeeeetaeeeeeeaeeeeneaa 55 2 7 X Tools V 04 00 IR1 gt X Tools V 04 00 IR2 ou ee eeeceeeeeeeneeeeeeeneeeeeeaeeeeeeaaeeeeeeaaeeeeetaeeeeeneaeeeeeaa 57 2 8 X Tools V 04 00 IR2 gt X Tools V D4 OO oooococonoccccconocccccononcccnnnoncncnnnnnnnnnnnnnncnnnnnn nn nana nn cc cane nnnci
217. to 1 MByte 1048576 characters CHANGE Removing of the Time Format YYYY MM from Time Axes The time format YYYY MM is not used by time axes any more because the distance between months is not equidistant Instead the time format YYYY MM DD is used in case there is enough space available and the time format YYYY is used when there is not enough space available CHANGE New Name for executable exe Files The exe files of X Tools have been changed in order to receive different names for each edition For example the executable files of the Professional edition now have the names X Tools Client Pro exe X Tools Server Pro exe X Tools Service Pro exe and X Tools Tray Pro exe BUGFIX Incorrect Operation in Combination with the third party Project Viewer Tool In case the XSI dll was used by the third party Project Viewer tool the data streaming could not be started in some cases In other cases also a crash of the X Tools Server was possible BUGFIX Possible Crash of the X Tools Server A certain timing could lead to a race condition during the preparation of an automatic report As a result the X Tools Server could attempt to access already freed memory and it could crash afterwards English Release 2014 11 58 81 CMS X Tools Change Log CMS BUGFIX Possible Crash of the X Tools Client In case the mouse wheel was used within the AME Standard T001 or UFE Stand
218. trum over the time in a 3 dimensional space The Monitoring Chart also can be switched to a view from the top spectrogram or from the front FEATURE More advanced automatic Updating of the Time Interval of a MTC yt T001 The value of Rescale t Axis after Open and of Rescale t Axis after Action can be configured to No Fit to Time Interval Update Start Time and to Update Stop Time now FEATURE More advanced automatic Updating of the Time Interval of a MTC yx T001 The value of Update Display Time after Open and of Update Display Time after Action can be configured to No Fit to Time Interval Update Start Time and to Update Stop Time now FEATURE More advanced automatic Updating of the Time Interval of a MTC yn T001 MTC ynm T001 MTC Orbit T001 or MTC Vector2D T001 The value of Update Display Time after Open and of Update Display Time after Action can be configured to No Show Start Time and to Show Stop Time now English Release 2014 11 57 81 CMS X Tools Change Log CMS FEATURE Formula Editor within the MVE Standard T001 The Formula Editor table of the MVE Standard T001 allows to run simple calculations directly within the Moni toring System FEATURE include Statements for Analyzing Scripts Analyzing Scripts can include other Analyzing Scripts from now on in order to access the variable constant and function definiti
219. ts of this feature is that it now is possible to have multiple Analyzing Models Analyzing Scripts in a row where always one Analyzing Model Analyzing Script inputs data which was output by previous Analyzing Models Analyzing Scripts FEATURE Support for Databases from V 2 x of the SIPLUS CMS2000 System In addition to databases from V 1 x of the SIPLUS CMS2000 System X Tools now also can read the data from databases which have been created by V 2 x of the SIPLUS CMS2000 System FEATURE Additional Analyzing Function ShowPath The Analyzing Function ShowPath is able to determine the absolute and or symbolic path to its parent Ana lyzing Model Analyzing Script The returned path can be used by following Analyzing Functions FEATURE Storage IDs Storage IDs can be used within Storage Profiles now in order to add the current value of a data to the path and or file name of the to be stored offline data FEATURE Advanced Path and File Name Configuration for Storage Profiles The Path Configuration and File Name Configuration dialogs within the SPE Binary T001 now allow to con figure the to be created directory paths and file names in a very flexible way CHANGE Maximal Number of Alarm Band Inputs for MonAlrmSpm The maximal number of alarm band inputs has been increased from 16 to 32 CHANGE Support for Monitoring Views through Control Analyzing Functions The Analyzing Functions Start Pause Continue Stop and Wai
220. ttons The global option Size of Toolbar Buttons provides an additional option for choosing of a medium 150 toolbar button size FEATURE Adding of the Average Column to the Measurement Cursors Table of the MTC yt T001 The Average column of the MTC yt T001 shows the average value of each data for the period of time between the current measurement cursors FEATURE Improved Customization within all Cursor Marker Tables of Monitoring Charts The cursor marker tables of all Monitoring Charts now allow to move and to re arrange the present columns In addition all columns which display a time allow to configure the format of the displayed times via the context menu of their column caption FEATURE Adding of the Type Input Argument to the Analyzing Function GetVFrmSD The Type input argument can be used in order to define whether the data which is specified via the Name input argument is an online data or an offline data FEATURE Adding of the Type Input Argument to the Analyzing Function IsDataPrsnt The Type input argument can be used in order to define whether the data which is specified via the Name input argument is an online data offline data or a scalar data FEATURE Update and parallel Installation via the Setup When the setup of X Tools is started and there is an older version of X Tools installed already the setup allows to choose whether the existing installation sh
221. two input data FEATURE Startup of X Tools with Startup Configuration Files The new global option Startup Type of the X Tools Server allows to choose whether the X Tools Server shall automatically restart all Configuration Files which were running during its shutdown or whether a certain Analyz ing Script shall be used in order to startup all Configuration Files in a defined order FEATURE Adding of Support for SIMATIC S7 12xx and SIMATIC S7 15xx CPUs SIMATIC S7 12xx and SIMATIC S7 15xx CPUs can be connected via the ION SIMATIC S7 1200 and ION SIMATIC S7 1500 The communication with both devices takes place over TCP IP and the Socket T001 inter face of X Tools FEATURE Parameters for Analyzing Scripts The ASE Standard T001 now allows to configure input arguments of Analyzing User Functions as parameters of the parent Analyzing Script Such an Analyzing Script with parameters can be started via the Analyzing Func tion StartEx in order to pass the desired parameters to it FEATURE Visualization of Frequency Spectrums as Order Spectrums within the MTC yn T001 The MTC yn T001 now allows to show the amplitudes of a frequency spectrum as order spectrum Therefore the x axis can be switched from Linear to Order and the frequency divider value can be provided as user entered number or as speed data English Release 2014 11 74 81 CMS X Tools Change Log CMS FEATURE Variable Size of Toolbar Bu
222. uble clicks onto or opens any of the files of X Tools FEATURE Automatic Symbolic Name within the Add Location Dialog In case the value of Symbolic Name within the Add Location dialog is empty at the moment when a new path is chosen for the Path cell the last directory name is inserted as default value for the Symbolic Name FEATURE Automatic Selection of dropped items within AME Standard T001 and UFE Standard T001 Whenever a new item is or multiple new items are dropped into the AME Standard T001 or UFE Standard T001 all of the newly dropped items automatically become selected after the drop This allows to move copy the newly dropped items easily FEATURE Support for lt Ctrl gt lt f gt within the System Log Viewer In case the System Log Viewer has the input focus at the moment and lt Ctrl gt lt f gt is being pressed the Find String cell within the System Log Settings table is put into editing mode and the new find string can be en tered directly FEATURE Adding of Information about installed Hotfixes to the System Log In case X Tools detects a binary file which contains a hotfix an according log entry is added to the system log FEATURE Update of the MDS Explorer via lt F5 gt In case the MDS Explorer has the input focus lt F5 gt can be pressed in order to re read all of the displayed in formation about online and offline data from all of the currently connected X Tool
223. ue While the calculation is running the one and only probe can be overwritten multiple times e g in order to store the maximal value of a curve at the moment when this maximum has been reached for the first time FEATURE Additional Output Mode Advanced Append for Output Analyzing Functions The additional output mode Advanced Append can be used in order to always append the current calculation results to the results from the last calculation and to limit the maximal size of the created output data at the same time The maximal allowed size of the output data can be configured and the output Analyzing Functions automatically remove the oldest probes of the output data in order to grant the configured maximal size FEATURE Connecting of Unit and Description within Analyzing Programs The Unit and Description input arguments of all output Analyzing Functions now can be connected via links Thus it becomes possible to connect the Unit and Description output arguments of input Analyzing Functions to the Unit and Description input arguments of output Analyzing Functions FEATURE Parameters for Analyzing Models The AME Standard T001 now allows to configure input arguments of Analyzing User Functions as parameters of the parent Analyzing Model Such an Analyzing Model with parameters can be started via the Analyzing Function StartEx in order to pass the desired parameters to it FEATUR
224. und Images within the MTC Mimic Board T001 could be displayed wrongly In case the background image within a MTC Mimic Board T001 had a width of more than 1024 pixels it could be displayed wrongly within automatic reports and when the Graphics Library was configured to OpenGL 1 1 no hardware acceleration English Release 2014 11 79 81 CMS X Tools Change Log CMS 3 List of Abbreviations Abbreviation Description AME Analyzing Model Editor ANF Analyzing Function ANS Analyzing System ANX Analyzing System Explorer ASE Analyzing Script Editor CTN Control Node DMS Device Management System DMX Device Management System Explorer DPE Device Profile Editor GOE Global Options Editor IFN Interface Node ION 1 O Node Input Output Node IPE Interface Profile Editor LPE Loading Profile Editor MDS Master Data System MDX Master Data System Explorer MMS Main Management System MMX Main Management System Explorer MPE Main Profile Editor MTC Monitoring Chart MTS Monitoring System MTX Monitoring System Explorer MVE Monitoring View Editor ODL Offline Data Loader UAE User Accounts Editor SLV System Log Viewer SPE Storage Profile Editor STS Storage System STX Storage System Explorer UFE User Function Editor UPS Uninterruptible Power Supply USF User Function XTC X Tools Client XTS X Tools Server
225. w daylight saving time X Tools was not able to startup at all BUGFIX Unwanted enabling of empty Rows within the Loading Profile Editor The Loading Profile Editor allowed to enable the last empty row within its Included Data and Excluded Data tables BUGFIX Ignored Difference of Time Domains within Interface Profiles for the Socket Interface Assume an Interface Profile for a socket interface which has established the connection to a socket device In this situation another Interface Profile can be started for the same socket interface directly without stopping of the previous Interface Profile before At the moment of the start of the second Interface Profile X Tools checks whether any of the currently connected socket devices is also present within the new Interface Profile In case yes the socket device keeps connected without any interruption The according check did not consider that the same device may have different time domain settings within these two Interface Profile thus it was possible that the socket device was not reconnected although its different time domain would have required a reconnect BUGFIX Improper highlighting of negative Gradients of the Normalization Although negative values for the gradient m of the normalization are allowed and could be stored all Device Profile Editors highlighted negative gradients with red color BUGFIX Background Color of Monitoring Charts is not restored After opening of a Monitor
226. was configured to Boolean the index was calculated wrongly As a result the values for the Boolean outputs did not use the proper values from the input data and the outputs provided wrong results BUGFIX Doubled Start Events within Offline Data Files In case some offline data was stored via a Storage Profile the resulting offline data files could contain double start events BUGFIX Possible Error within high precision decimal Operations The handling of high precision decimal calculations was not thread safe in all cases There was a small chance to see e g wrong visualizations within the Monitoring System because of this issue BUGFIX Possible suspend of Device Profiles for Software I O Nodes after a Time Change In case a change of the system time takes place while the Device Profile for a software I O Node e g ION SIMATIC S7 300 T001 ION SIMATIC S7 PN is running the Device Profile could suspend forever respec tive until it is stopped and started manually again The reason was a race condition between releasing of the necessary license because of the stop of the Device Profile during the recovering from the time change and the attempt to lease the license again during the restart of the Device Profile during the recovering from the time change BUGFIX Unwanted stop of the Data Streaming to the XSI In case the data streaming for a data was active already and XSIStariOnlineDataStreaming was called twice after each
227. yzing Script was suspended After the suspend it could start again from the beginning which caused the same suspend at the same place in most cases Now the parent Analyzing Script does not suspend any more in case Analyzing Functions like Start return an error BUGFIX Possible Crash after exporting or storing of offline Data A crash could occur in case offline data of certain spectrum data types was exported or stored via the MDS Explorer BUGFIX Wrong Handling of the Reset Input through the Analyzing Function TLC In case the Reset input argument of the Analyzing Function TLC became true the Analyzing Function has reset too much of its internal state information As a result the input data from the first cycle after Reset be came false again was lost BUGFIX Export to DIAdem did not work via the MDS Explorer In case the export of offline data to the DIAdem file format was started via the MDS Explorer the resulting file could be of 0 bytes size contrary exporting via the ODL Standard T001 worked properly already BUGFIX The Interpolation Mode None does not work properly in Action based Operating Modes In case the interpolation mode of the input Analyzing Functions InB1D InB2D and InSpm was None these inputs did not return any values in action based operating modes BUGFIX Possible wrong Width of Screenshots out from Monitoring Views In case the width of a Monitoring View at the moment
228. zed manually after the automatic resize BUGFIX Inverted Operation of Main Profiles There was a possibility that the X Tools Client started to show connected X Tools Servers after stopping of the English Release 2014 11 31 81 CMS X Tools Change Log CMS current Main Profile In this situation all X Tools Servers also disappeared from the X Tools Client when the Main Profile was started again BUGFIX Mouse Wheel Operations and the undo redo Buffer of the MTC ynm T001 Zooming operations via the mouse wheel where not added to the undo redo buffer of the MTC ynm T001 and therefore they could not be undone redone BUGFIX Global Variables within Analyzing Scripts could not be initialized with negative Values It was not possible to create and initialize global variables within Analyzing Scripts when the initial value was negative BUGFIX Storage Profiles for offline Data did not work for the Stop Triggers which were based on Data In case a Storage Profile was configured to store offline data and in case the stop trigger of this Storage Profile was configured to base on the value of a data the Storage Profile stopped even in case the specified data for the stop trigger was present as offline data BUGFIX Possible Crashes in case of low Memory Conditions Several places have been secured against crashes in case of low memory conditions BUGFIX Handling of Time Zone Changes of the X Tools Server through Monitoring Charts In case a M

Download Pdf Manuals

image

Related Search

Related Contents

Bryant 311AAV Furnace User Manual  Les thèmes du portail – Manuel d`utilisation  PDF版 - 消費者の窓  MANUAL DE INSTRUÇÕES BBW-2500 BALANCEADORA  Hampton Bay FNK8991A Instructions / Assembly  Pfister KSD-LCCC Installation Guide  B4-M500(black) - LaBoutiqueDuNet  Guia de utilização do manual de instruções    Guia de Usuario Español MVT600  