Home
Manual - Enovate Medical
Contents
1. STEP 2 si Remove VESA plate from the monitor LR mounting bracket STEP 3 Mount the VESA plate to monitor using the 4 M4x12 pan head screws provided Component Installation e MANUAL STEP 4 Place the monitor and attached VESA plate back into the monitor mounting bracket PLUG VGA CABLE TO PC AND POWER CORD FROM WCC CONTROLLER INTO MONITOR SEE PAGE 16 STEP 5 Close the display glass CPU Bracket The e750 is eguipped with a universal CPU bracket that will accommodate CPU s with maximum dimensions of 10 5 x 10 75 x 2 6 STEP 1 Loosen thumb screw and move CPU bracket to its upper most position STEP2 Put the CPU in place STEP 3 Loosen thumb screw and move the CPU bracket so it snugly holds the CPU in place Tighten thumb screw Adjustments KEYBOARD TRAY GAS SPRING ADJUSTMENT STEP 1 To adjust the keyboard tray closing tension turn adjustable gas spring bracket screw Turn clockwise to increase tension and counterclockwise t
2. R jim 2 57 11 To AC Power li TwoWay Additional Power Power Splitter To PC Power To PC USB e b m 1 Controller Box n 4 7 WCC y Power WCC CONTROLLER BOX Pre Wired for To PC Keyboard amp Mouse e To Monitor Pre Wired From Power Splitter THREE WAY SPLITTER To AC Power Three Way Power Splitter Pre Wired Additional To WCC Power In Power Source rz PC Power 4 Mount keyboard to keyboard tray with supplied 3M Dual Lock Squares Be sure keyboard does not cover round metal plate 5 Plug keyboard and mouse into the USB hub that is pre wired into the keyboard tray Cleaning Instructions Use non abrasive cleaners or mild cleaning solutions Do not use abrasive cleaners solvents polishes waxes or steam cleaning tools As a precaution to test the suitability of a cleaning product apply to an inconspicu ous area minimizing the time of exposure and the amount of cleaning agent dilut ing as recommended by the supplier in order to prevent any damage to the surface Contamination by intensively colored substances for example
3. 13325 3 Enter the 5 digit range code for the proximity sensor from the table below 4 Pause for 2 seconds 5 The green LED flashes twice for success The new range has been saved and activated RANGE CODE a Te me 26 Keypad Operations MANUAL 27 28 Warranty e MANUAL How We Help You Support services provided along with the standard warranty must be requested within the expressed warranty time frame for the product element e Technical support may request customer collaboration and assistance during diag nosis to provide for next business day service resolution Typically this requires but is not limited to e Identifying a primary contact representative with phone number and e mail ad dress to work with Enovate Medical and answer relevant questions e Providing the serial ID number and access to the product Performing basic troubleshooting activities as directed by Enovate Medical s Technical Support Resolution methods can include but are not limited to any of the following Verbal written instructions to correct the problem Shipping of replacement parts OR a product swap On site dispatch of an Enovate Medical authorized service technician If needed Enovate Medical will involve its design engineers or supplier partners for resolution assistance and customer s satisfaction Determination for resolving war ranty issues will be at Enovate Medical s sole discretion Technical Support Assist
4. Units Only Hardware HARDWARE INCLUDED 4x SNAPTOGGLE Anchor 1x Height Restriction Bracket Lift Models Only 8x H10x2 1 2 Pan Head Screw 2x 87 1 4 20 x 3 4 Button Head Screw Lift Models Only 4x 10 x 1 4 Standoff 10x Cable Tie amp Adhesive Pad DD TD M4 12mm Pan Head Screw P M4 x 16mm Pan Head Screw 4x Dual Lock Pads TOOLS NEEDED Drill 1 8 Allen Wrench Hardware MANUAL Ed Es Le Level Mounting MANUAL e750 with eLift Mounting Diagram NOTE It is recommended that the e750 is mounted to wall studs a 21 I I 3 I WALL STUDS li LI I d l 17 12 2 a I u I r 18 i gt I il i D Power Data Location i 18 46 2 1 1 i 20 50 5 E gt Y MI 1 5 LI 22 29 63 Lo a I 30 5 FLOOR Mounting MANUAL e750 Non Lift Mounting Diagram NOTE It is recommended that the e750 is mounted to wall studs WALL STUDS IA B M Power Data Location 1 1 E 46 2 60 5 29 63 L 40 5 FLOOR Mounting In Room Installation STEP 1 Determine your desired keyboard height The dimension
5. 2 50 Wallstation The Enovate Medical e750 Wallstation was designed to set a new standard in guality Enovate Medical s goal is to provide a wallstation ready for years of use and backed by a commitment of exemplary service and support Thank you for purchasing the Enovate Medical e750 Wallstation 2013 Enovate Medical LLC All Rights Reserved Content is subject to change without notification IMPORTANT WARNINGS Read the entire installation manual before you begin MOUNTING Installer must verify that the entire wall will safely support the combined weight of all attached eguipment and hardware Improper installation of this product can cause extensive property damage or serious personal injury either during or after installation It is the responsibility of the installer to ensure that all applications including wood concrete block brick steel etc are secured properly and are in compliance with local and national building codes California installations could require specific anchorage and additional mounting screws Check with local authorities for codes in your area Other seismic states have similar regulations WARNING Because wall surfaces and construction methods and materials vary it is imperative that you consult with the appropriate engineering architectural or construction professional to ensure hat your Wall computing station is mounted properly to handle the applied loads ELECTRICAL SHOCK HA
6. Tray Unlock Time Keyboard Light Opening State Open Mode User PIN only Close Mode Prox timeout Close switch or door close 20 Keypad Operations MANUAL USER FUNCTION LOCKING KEYBOARD TRAY PIN TO OPEN 1 Enter your assigned PIN code wait until green light flashes DO NOT PRESS THE 8 0 BUTTON 2 Pull keyboard tray down 3 Log on to computer NOTE You must be standing in front of the wallstation for keyboard tray to remain open TO CLOSE 1 Log off computer 2 Slide mouse toward back of keyboard tray away from edge 3 Press 8 4 to close keyboard tray NON LOCKING KEYBOARD TRAY TO OPEN 1 Pull keyboard tray down 2 Log on to computer NOTE You must be standing in front of the wallstation for keyboard tray to remain open TO CLOSE 1 Log off computer 2 Slide mouse toward back of keyboard tray away from edge 3 Press to close keyboard tray 21 Keypad Operations MANUAL eLift Models Only enovate Adjusting the Wall Unit Height 1 Press and hold the Up or Down switch to adjust the height of the wall unit There is a 12 height adjustment from the lowest keyboard height unless the height restriction bracket has been installed Activating the Keyboard Light 1 Press the enovate logo on the keypad to turn the light on MEDICAL MEDICAL 22 Keypad Operations MANUAL Administrative Functions All code entries require five key press
7. ZARD Cutting or drilling into electrical wires and cables can cause FIRE DEATH or SERIOUS PERSONAL NJURY Always make certain the area behind the mounting surfaces is free of electrical wires and cables before drilling into wall EXPLOSION AND FIRE HAZARD Drilling into gas plumbing can cause EXPLOSION FIRE DEATH or SERIOUS PERSONAL INJURY Always make certain the area behind the mounting surface is free of gas water waste or any other plumbing before drilling GROUNDING Connect the Enovate Medical Wall Station to a grounded receptacle SERVICE AND REPLACEMENT Do not attempt to service or replace any part of the Enovate Medical Wall Station unless directed to do so through Enovate Medcial approved documentation i e this User Manual or other instructions Only Enovate Medical or an Enovate certified entity may service or replace the wall station compo nents If any component on the wall station is missing or damaged the wall station must not be used Contact Enovate Medical immediately to request service If the unit is not working properly please contact Enovate Medical Customer Service toll free at 888 909 8930 or by email at support denovatemedical com ao P N o 12 14 15 16 19 Table Of Contents MANUAL WELCOME WARNINGS HARDWARE MOUNTING HEIGHT RESTRICTION BRACKET COMPONENT INSTALLATION UNIVERSAL CPU BRACKET ADJUSTMENTS CABLE MANAGEMENT KEYPAD OPERATIONS Lift amp or Locking
8. ance Service requests can be made at any time via Enovate MedicaUs support website or by phone 1 888 909 8930 www enovatemedical com support Support hours are Monday Friday 8 am 6 pm ET except holidays Enovate s Response Pledge Areply to all service requests within 2 hours of their submittal during business hours Service resolutions by the next business day 29 enovate MEDICAL 1152 Park Avenue Murfreesboro TN 37129 888 909 8930 f 615 896 8906 www enovatemedical com support enovatemedical com 2013 Enovate Medical LLC AU Rights Reserved
9. coffee mustard curry or red wine have to be removed immediately Keypad Operations Electronic Lift amp or Locking Units Only enovate MEDICAL 1 Keypad There are five keys that are used to enter 5 digit PIN codes LED A single multi color LED on the keypad provides feedback to the user as key sequences are pressed The LED can appear as green or red LED COLOR FLASH ONCE FLASH TWICE Each key press Successful operation Master Code There is one 5 digit Master PIN Code for use by the system adminis trator The Master Code is used to assign User PIN Codes and for other maintenance functions The factory default Master Code is 12345 User PIN Codes Up to 100 5 digit PIN Codes can be assigned for use by hospital personnel to access the wall cabinet keyboard When a user enters their valid PIN code the keyboard drawer unlocks and can be opened by user to allow access Additionally the LCD monitor is turned on and additional keys on the keypad become enabled for adjusting the height of the wall unit turning on the optional keyboard light and for closing the keyboard drawer The factory default User PIN Code is 54321 Reserved PIN Codes The following PIN codes are reserved for administrative usage These codes cannot be assigned as either the Master Code or as a User PIN Code Factory Defaults Summary For Locking Units All units are shipped from the factory with the following default values Keyboard
10. d Operations MANUAL How to Set the Close Mode for the Unit This option determines when the monitor will turn off The first option turns the monitor off when the proximity sensor timeout period expires due to the user walking away the user pushes the Close button or the keyboard tray is closed by the user The second option turns off the monitor only when the keyboard tray is actually closed all the way 1 Close the keyboard tray by pressing the Close switch 2 Enter the Master Code 3 Enter 13324 4 Enter the Close Code for the desired Close Mode from the table below Pause for 2 seconds 6 The green LED flashes twice for success The new Closing mode has been saved and activated 7 Press the Close switch CLOSE MODE DESCRIPTION CLOSE CODE Prox Timeout Close Switch or Door Close 11111 G1 How to Set the Proximity Sensor Delay Time 1 Enter the Master Code 2 Enter 13332 3 Enter the 5 digit time code for the reguired delay time from the table below 4 Pause for 2 seconds 5 The green LED flashes twice for success The new Delay Time has been saved and activated Be im famo pe sec ume amin jm fisse mm jm ke ums 1 0 ae man jem ma rose mur jem jme ke mm eem jm ose 5 2 11111 11112 11113 11114 11115 11121 11122 11123 11124 11125 25 Keypad Operations MANUAL How to Set the Proximity Sensor Range 1 Enter the Master Code 2 Enter
11. e for success All User PIN Codes have been deleted and the factory default PIN code 54321 restored 23 Keypad Operations MANUAL How to Turn On the USB Interface 1 Enter the Master Code 2 Enter 13321 3 Pause for 2 seconds 4 The green LED flashes twice for success The new state has been saved and activated When the USB interface is turned on key presses will be sent to the PC over USB just like a standard keyboard How to Turn Off the USB Interface 1 Enter the Master Code 2 Enter 13322 3 Pause for 2 seconds 4 The green LED flashes twice for success The new state has been saved and activated How to Set the Keyboard Light Opening State 1 Enter the Master Code 2 Enter 13331 3 Enter 11111 to turn the light on or 11112 to turn the light off at open 4 Pause for 2 seconds 5 The green LED flashes twice for success The new opening state has been saved and activated How to Set the Open Mode for the Unit 1 Close the keyboard tray by pressing the Close switch 2 Enter the Master Code 3 Enter 13323 4 Enter the Open Code for the desired Open Mode from table below 5 Pause for 2 seconds 6 The green LED flashes twice for success The new Opening mode has been saved and activated OPEN MODE DESCRIPTION OPEN CODE Open by User PIN only 11111 Open by User PIN or Close button press 11112 Open by pulling down the keyboard tray 11113 Option 3 is for non locking units only 24 Keypa
12. es Too few or too many key presses will result in a failed operation NOTE All administrative func tions must be completed with the keyboard tray in the closed position Please note that in all of the following examples it is advised to have all key strokes written down for the desired operation If there is a pause of 2 seconds or longer between any two keys the red LED will flash twice to indicate a failure To cancel an operation stop pressing keys and let the operation fail due to a timeout When an operation com pletes successfully there will be two green flashes Changing the Master Code 1 Enter the current Master Code 2 Enter the current Master Code again 3 Enter the new Master Code 4 Pause for 2 seconds 5 The green LED flashes twice for success The new Master Code has been saved and activated IMPORTANT RECORD YOUR MASTER CODE AND SAVE IT IN A SAFE PLACE Adding a User PIN Code 1 Enter the Master Code 2 Enter 13344 3 Enter the PIN Code to add 4 Pause for 2 seconds 5 The green LED flashes twice for success The PIN Code has been saved and activated Deleting a User PIN Code 1 Enter the Master Code 2 Enter 13341 3 Enter the PIN Code to delete 4 Pause for 2 seconds 5 The green LED flashes twice for success The PIN Code has been deleted Deleting All User PIN Codes and Restoring the Default PIN Code 1 Enter the Master Code 2 Enter 13342 3 Pause for 2 seconds 4 The green LED flashes twic
13. etal Stud STEP 3 Snap straps at wall by push ing side to side snapping off straps level with flange of cap Patented under one or more of the follow ng U S Patent Nos 4 993 901 5 028 186 5 161 296 5 238 385 6 161 999 7 144 212 7 320 569 and foreign counterparts thereof and of 4 650 386 and 4 752 170 Other patents pending TOGGLER and typeface symbol TA TB TC TH ALLIGATOR SNAPTOGGLE and SnapSkru are worldwide registered trademarks of Mechanical Plastics Corp eLift Models Only Height Restriction Bracket Optional The e750 has an optional height restriction bracket that can be installed if there is a low ceiling condition where vertical travel is limited Refer to the following diagrams for three mounting options The height restriction bracket should only be used to prevent ceiling damage When the wallstation comes into contact with the bracket it will shut the unit off Height restriction bracket mounting holes Mounting MANUAL COT R OPTION 1 Restricts vertical movement to 6 total Hole 3 LO Hole 2 Iw OPTION 2 Restricts vertical movement to 8 total 0 Hole3 oll O Hole 2 0 Hole 1 OPTION 3 Restricts vertical movement to 10 total Hole 3 Hole 2 O Hole 1 Component Installation MONITOR INSTALLATION STEP 1 Unlock and open the component door and display glass
14. o decrease tension NOTE Do not over adjust as this may defeat the closing mechanism LATERAL ADJUSTMENT Turn front spiral tech cam screw to increase or decrease door overlay DEPTH ADJUSTMENT Turn rear spiral tech cam screw to adjust door position HEIGHT ADJUSTMENT Rotate cam screw on plate to adjust door position Cable Management Cable Management eLIFT 1 Attach the USB cable from the WCC Controller Box to the PC 2 Plug LCD VGA cable into CPU 3 Plug the power from the three way splitter to the PC Power skip to page 18 To AC Power Three Way Power Splitter To PC USB To PC Power Yl Le b i j WCC itor Power Controller Box line z k VS WCC CONTROLLER BOX THREE WAY SPLITTER Power Pre Wired for Keyboard amp gt enote Ec B SENSOR Ea ar 0 du NGE Boves lh Ze bek To Monitor Pre Wired From Power Splitter To PC Power Cable Management NON LIFT 1 Attach the USB cable from the WCC Controller Box to the PC 2 Plug LCD VGA cable into CPU 3 Plug the power from the two way splitter to the PC Power
15. s on drawing see page 6 and 7 are shown for a keyboard height range of 30 5 to 42 5 Adjust dimensions as reguired for desired height STEP 2 Locate the exact center line of the wall studs STEP 3 Using a level mark two horizontal lines at the distance from finish floor shown on the drawing on page 6 and 7 STEP 4 Drill 4 1 2 holes through the center of the wall studs and install 4 SNAPTOGGLE brand metal stud wall anchors See wall anchor installation instructions on page 9 STEP 5 Screw Wallstation to the wall using the 10 Pan Head Screws provided Check the Wall Station for level before tightening completely NOTE Remove the monitor mounting bracket for easy access to the mounting key holes METAL STUD MOUNTING Back Plate Wall Metal Stud 7 E SNAPTOGGLE m 10x2 ve Pan Head Screw SNAPTOGGLE METAL STUD ANCHOR INSTALLATION STEP 1 Drill a 1 2 hole through cen ter of metal stud Hold metal channel flat alongside plas tic straps and slide channel through hole Must be 1 7 8 minimum clearance behind wall for channel rotation STEP 2 ao ETL Metal stud Hold ends of straps between Mim EES thumb and forefinger and NS pull toward you until channel rests flush behind wall Slide Ci di plastic cap along straps with other hand until flange of cap is flush with wall M
Download Pdf Manuals
Related Search
Related Contents
Manual USER`S MANUAL USER`S MANUAL - Trenz Electronic Operating Instructions (Hungarian) Samsung 320P Bruksanvisning www.disney.fr/toystoryjeuvideo questions-réponses TECDIS USER MANUAL User Manual - Tempco Electric Heater Corporation Lettori Biometrici e di Prossimità modd. FGR006 Copyright © All rights reserved.