Home
PH201G (Style B) Distributor
Contents
1. Unit mm 180 160 Y 2 95 8 Mounting Holes Grounded Power code Figure 1 1 PH201G Au B Distributor External Dimensions Unit mm 180 160 2 95 8 Mounting Holes Figure 1 2 PH201G Au B TB Distributor External Dimensions IM 19B01E04 02E 2 2 1 lt 2 Installation gt 2 1 Installation Unpacking and Verifying Specifications This instrument was thoroughly inspected at the factory before shipment When you have received it please check visually to verify that no damage has occurred Also check that the spare fuse a standard accessory is present The model and suffix codes are inscribed on the nameplate attached to the front of the instrument Check the product model and suffix codes on the instrument s nameplate against those listed in Section 1 2 to verify that the product is exactly what was ordered Should any questions arise please contact your sales representative or YOKOGAWA sales office The spare fuse is located inside DISTRIBUTOR MODEL PH201G 80 138V AC 47 63Hz Figure 2 1 Location of Nameplate IM 19B01E04 02E 2 2 lt 2 Installation gt 2 2 PH201G Distributor Construction The PH201G distributor is a rack instrument It has a 2 piece construction that enables the internal
2. 1 3 External DIMENSIONS E 1 3 2 AP OR ARN RR IN E COR 2 1 2 1 Unpacking and Verifying Specifications nenea 2 1 2 2 PH201G Distributor Construction css rr nneeneaeeneaea aaa 2 2 2 3 Rack Constructions eine nennen it a Han a aa aa ana EEN 2 3 2 4 MOUNtING iscsi ceia ceda i ata oa dace E dau aaa dea odaia da ata oa aaa da sia 2 4 2 5 Removing the Internal Unit c eee nene nenea nenea nana nenea 2 6 2 6 External WIFI Doc aa aie anii pa Dada aa in Ea a ar aaa bi 2 7 3 Operating Principles e occ 3 1 3 1 Loop Isolation ssss is ns e i in ii a tii ina E it i 3 1 3 2 Communications Function cocnccconccnnnononnnncnnnncnnnnn canon canon cancer nana 3 2 4 O E 4 1 4 1 Components iia Ra 4 1 4 2 Pre Operation Checks ccecccseceesseeeeseeeeseeeeseeeeseeeesaeeeneeeeseeseseeeeseneeseeeenaes 4 2 4 3 Communication Output ueuurresssnsnnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnn 4 2 5 Maintenance id 5 1 5 1 F se Replacement nen een 5 1 6 Trouble shooting E 6 1 6 1 Troubleshooting Flowchart uuunensennnennnennnennnennnunnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 6 2 6 2 Part Replacement Procedure 22442204442024400nnnn0nnnnnnnnnannnnannnnan nennen 6 3 6 2 1 Power Unit Removal men aa 6 3 6 2 2 Main Card EE EE 6 3 6 2 3 Cover Removal nenea aaa amana aaa an 6 3 Customer Maintenance Parts List nssnsenseennnnnnnnnnnnnnnnnnn CMPL 19B1E4 01E
3. Revision Information ci an i IM 19B01E04 02E lt 1 Overview gt 1 1 1 Overview This distributor designed exclusively for use with these 2 wire transmitter supplies drive power to the 2 wire transmitter while simultaneously receiving 4 to 20 mA DC current signal from the transmitter and converting it to 1 to 5 V DC voltage signal it also simultaneously receives a digital signal superimposed on 4 to 20 mA DC signal and provides contact outputs during hold failure and or cleaning A current limiter function is built into this unit so it can continue to operate properly even with a short circuit on the transmitter side 1 1 Standard Specifications lt Input Output Signal Specifications gt Number of input points Number of transmitter units connectable 1 point Output signal 1 to 5 V DC 2 points Load resistance 2 KQ or more 1 to 5 V DC Output Isolation system Loop isolation type lt Mounting Form gt Mounting method Indoor rack mounting Connection method External signal connection M4 screw terminal connection Power supply Ground connection 100 V JIS C8303 ground type 2 plug connection 220V CEE 7VII European electrical device standard plug connection Cable length 300 mm External dimensions 180H x 48W x 300D mm Weight Approx 1 7 kg Including rack and case lt Standard Specifications gt Accuracy 0 2 of span Transmitter supply voltage 26 5 1 5 V DC Insulation resistance Between I
4. unit to be separated from the rack case The internal unit is connected to the rack case by a multi pin connector so that it can be inserted and removed without disconnecting the external wiring to the instrument s terminals However in the case of a terminal connected power supply wired distributor or if wiring is connected to the contact signal terminals on the internal unit that wiring must be removed The rack case terminal board cover can be used as a handle for pulling out the internal unit Input outpit terminal board Terminal cover and handle for pulling out internal unit Rack case These terminala are not used Multipin connector Grounded power plug Contact signal terminals Note The figure shows the Model PH201G ACI B distributor The PH201G AO B TB lacks a power cord with a ground plug having instead a power connection terminal board on the internal unit Figure 2 2 PH201G Distributor Construction IM 19B01E04 02E lt 2 Installation gt 2 3 2 3 Rack Construction The PH201G distributor can be mounted on the same rack as other YOKOGAWA rack instruments Figure 2 3 is a configuration for mounting several rack instruments as a group The angle iron used for mounting must be strong enough to support all of the instruments The example in Figure 2 3 illustrates general practice using an angle iron 40340 mm wide and 5 mm thick For safety and to prevent problems with the cables used for electri
5. 3 Refer to Figure 2 11 or 2 12 to identify the individual terminals to which to connect the wiring 4 After completing wiring be sure to reinstall the contact signal terminal cover and the internal unit serves also as a lock to prevent the internal unit from being removed from the case accidentally Check that the internal unit is firmly inserted OUT1 1 to 5V DC CMN Common OUT2 1 to 5V DC CMN Common CMN For safety barrier gt Not used Contact signals HOLD hold FAIL failure WASH cleaning Terminal for contact signals Terminal symbol A B C D F H J K 1 2 3 4 5 6 7 8 a b c d ef Note Terminal symbol mark of a to f for contact signals are not printed Figure 2 11 Terminal Assignment Diagram and Wiring For Units with a Power Cord IM 19B01E04 02E 2 8 lt 2 Installation gt OUT1 1 to 5V DC CMN Common OUT2 1 to 5V DC CMN Common CMN For safety barrier Not used Not used Power supply Contact signals HOLD hold Terminal symbol A B C D F H J K 1 2 3 4 5 6 7 8 a b c d ef Contact FAIL failure signal WASH cleaning terminals Power supply AC or DC either polarity Grounding Note Terminal symbol mark of a to f for contact signals are not printed Figure 2 12 Terminal Assignment Diagram a
6. O terminals and ground pin 100 MQ 500 V DC Between power supply pins and ground pin 100 MQ 500 V DC lt Operating Specifications gt Ambient temperature 0 to 50 C Ambient humidity 5 to 90 RH Non condensing Power supply Dual use AC DC 100 V DC power 20 to 130 V no polarity AC power 80 to 138 V 47 to 63 Hz 220 V DC power 120 to 340 V no polarity AC power 138 to 264 V 47 to 63 Hz Maximum current and power consumption 24 V DC Approx 200 mA 100 V AC Approx 7 VA 220 V AC Approx 11 VA IM 19B01E04 02E 1 2 lt 1 Overview gt lt Contact Output gt Contact rating 250 V AC maximum 100 VA 220 V DC maximum 50 VA Hold contact output N C 1 contact Normally energized Contact closes when power is off or during maintenance Failure contact output N C 1 contact Normally energized Contact closes when power is off or during failure Cleaning contact output 1 contact Close during cleaning only Used as drive contact for solenoid valve for cleaning lt Regulatory Compliance gt Korea Electromagnetic Conformity Standard Class A Ad 7171 AFS YES ATA 91711 HFS AP 144447724 EW ALGAE 9 BS FASHA ak 8AA AANA AE AS 208 gg 1 2 Model and Suffix Codes at BAA 7 N Model Suffix Code Option Code Specification ENEE Distributor Power Supply 100 VAC 220 V AC Style B Terminal for Power connection IM 19B01E04 02E lt 1 Overview gt 1 3 1 3 External Dimensions
7. unit and the case is properly mated 2 Check that external wiring to the terminal boards has been performed correctly 3 Ifthe unit has a power cord check that the grounded power plug is correctly inserted into the receptacle 4 3 Communication Output The individual relay contact outputs for fail wash and hold will be in the states shown below depending on whether the power is ON or OFF for a PH201G distributor and whether communications are ON or OFF for a 2 wire transmitter Table 4 1 a Transmitter u communications and power status PH201G power ES peer IM 19B01E04 02E lt 5 Maintenance gt 5 1 5 Maintenance 5 1 Fuse Replacement When a fuse open circuits investigate and deal with the cause and then replace the fuse as below If the cause of the loss of continuity is the fuse itself it is possible that the fuse holder is dirty or the contact is bad and this should be checked 1 Detach the open fuse by pulling it strongly in the direction indicated by the arrow in Figure 5 1 and remove it 2 Install a new fuse after checking its rating Fuse Rated current 1A P N A1609EF Figure 5 1 Fuse Replacement IM 19B01E04 02E lt 6 Trouble shooting gt 6 1 6 Trouble shooting If a problem occurs during operation take corrective action according to the troubleshooting flowchart in Section 6 1 Consult your YOKOGAWA service representative if serious tro
8. wires connecting to the contact signal output terminals and also the power wiring in the case of a terminal connected power wired model see Figure 2 6 Do not connect the wiring to the contact signal output terminals or to the power supply ground terminals of a terminal connected power model at this time wait until after the internal unit is plugged into the case in 4 below Figure 2 6 Wiring 3 Connect the wiring that has been pulled through the ducts to the appropriate terminals See Section 2 6 External Wiring concerning connections to individual terminals IM 19B01E04 02E lt 2 Installation gt 2 5 4 Plug the internal unit into the case being careful to make sure that you are inserting it in the proper location There are labels on the internal unit and the case If tag numbers have been assigned to the labels compare them and make sure that they match before inserting the internal unit see Figure 2 7 If using contact signal out puts or terminal connected power wiring connect the relevant wires to the appropriate terminals Label Front view Rack case Figure 2 7 Location of Labels 5 Replace the cover on the terminal section If the instrument has a power cord insert the power plug into the receptacle above the instrument see Figure 2 8 Figure 2 8 Placement of Internal Unit IM 19B01E04 02E 2 6 lt 2 Installation gt 2 5 Removing the Internal Unit
9. It is sometimes necessary to remove the internal unit from the case to make adjustments and carry out maintenance on the instrument This section describes the procedure for removing the internal unit in such cases To remove the internal unit it is not necessary to remove the terminal board wiring Because the internal unit and the terminal board case are connected by a multipin connector separating them at this connector enables the internal unit to be removed from the case while leaving the wiring to the terminal board in place However if there is wiring to the contact signal terminals on the front of the internal unit or if it is a terminal connected power wired model that wiring must be removed 1 Unplug the power cord from the receptacle 2 Pull the terminal cover down toward you The cover also serves as a handle for removing the internal unit Hook your fingers around the terminal cover and pull out the internal unit Figure 2 9 Figure 2 10 Internal Unit Removal 2 IM 19B01E04 02E lt 2 Installation gt 2 7 2 6 External Wiring 1 Mount round M4 screw crimp terminal lugs on the wires to be connected to the terminals 2 Ifthe internal unit is already installed in the rack case pull the terminal cover down away from the terminals and connect the wires Wiring to the terminals on the internal unit such as wiring to the contact signal terminals should also be done with their terminal covers removed
10. User s Manual PH201G Style B Distributor IM 19B01E04 02E vigilantplant YOKOGAWA 4 IM 19B01E04 02E Yokogawa Electric Corporation 6th Edition lt INTRODUCTION gt i INTRODUCTION This instruction manual describes the procedures for installing wiring and carrying out sim ple maintenance on the PH201G distributor used in the 2 wire Type Transmitter System Please read this instruction manual through completely before working with the PH201G Media No IM 19B01E04 02E 6th Edition Apr 2014 YK IM 19B01E04 02E All Rights Reserved Copyright 2000 Yokogawa Electric Corporation lt INTRODUCTION gt For the safe use of this equipment m Safety Protection and Modification of the Product In order to protect the system controlled by the product and the product itself and ensure safe operation observe the safety precautions described in this user s manual We assume no liability for safety if users fail to observe these instructions when operating the product If this instrument is used in a manner not specified in this user s manual the protection provided by this instrument may be impaired Be sure to use the spare parts approved by Yokogawa Electric Corporation hereafter simply referred to as YOKOGAWA when replacing parts or consumables Modification of the product is strictly prohibited The following symbols are used in the product and user s manual to indicate that there are precautions for s
11. afety m Notes on Handling User s Manuals Please hand over the user s manuals to your end users so that they can keep the user s manuals on hand for convenient reference Please read the information thoroughly before using the product The purpose of these user s manuals is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product No part of the user s manuals may be transferred or reproduced without prior written consent from YOKOGAWA YOKOGAWA reserves the right to make improvements in the user s manuals and product at any time without notice or obligation If you have any questions or you find mistakes or omissions in the user s manuals please contact our sales representative or your local distributor m Warning and Disclaimer The product is provided on an as is basis YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance IM 19B01E04 02E lt INTRODUCTION gt iii m Symbol Marks Throughout this user s manual you will find several different types of symbols are used to identify dif ferent sections of text This section describes these icons NWARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious inju
12. cal wiring use a plastic wiring duct and run the wiring that connects to the instruments through this dust Unless terminal board connection is specifically desired the rack instrument power supply and ground connections are provided via a power cord and plug a two prong plug with a ground connection JIS C8303 for 15 A 125 V service Connect this plug to a compatible receptacle See Figure 2 4 Unit mm Mounting screw hole M5 x 0 8 25 or more 25 or more Rack support Wiring duct Figure 2 3 Rack Configuration Example Receptacle strip separate from duct Receptacle strip mounted directly on duct Wiring duct Wiring duct Multi receptacle strip Multi receptacle strip Figure 2 4 Examples of Mounting a Receptacle Strip IM 19B01E04 02E 2 4 lt 2 Installation gt 2 4 Mounting The PH201G distributor can be mounted with the internal unit in the rack case but mounting is easier if the internal unit is removed 1 Insert the case into the rack Orient the case so that the multipin connector is on the left Align the two mounting holes on the case with the screw holes on the rack and fasten the case in place with two mounting screws M5x0 8 see Figure 2 5 Figure 2 5 Rack Case Mounting 2 Pass the electrical wires through the wiring duct and pull them out Run the wires connecting to the input output terminal board through the upper duct through the lower duct run the
13. nd Wiring For Units with Terminal Connected Power Supply Wiring IM 19B01E04 02E lt 3 Operating Principles gt 3 1 3 Operating Principles 3 1 Loop Isolation For a two wire transmitter approximately 26 5 V is supplied through a current regulator CL and a 4 to 20 mA current signal is obtained The current regulator orevents excessive current when there is a short circuit in the field wiring The current signal is converted to 1 to 5 V which passes through an output amplifier to become the output signal Communication output Wave shaping y Signal Fail 2 wire Transmitter Relay detection drive Wash circuit circuit r 0 Hold 1 OUT 2 Relay contact i outputs L OUT 1 CMN O CL Current regulator SWR Switching regulator power supply L1 L2 GND Figure 3 1 PH201G Distributor Block Diagram IM 19B01E04 02E 3 2 lt 3 Operating Principles gt 3 2 Communications Function If the communications setting of a 2 wire transmitter is set to communications ON as AC signal of approximately 500 Hz approximately 2 mA p p is superimposed on the 4 to 20 mA line Within this signal fail wash and hold signals are incorporated as serial signals The PH201G distributor distinguished ON and OFF individually for each of these three types of signals and outputs them as relay contact signals The signal update interval is approximately 1 2 seconds Notice Jumpe
14. r J1 in the upper middle of the printed circuit board is the Jumper associated with the communication operation Normally position of the jumper J1 is set to the lt a gt When the communication operation is not stable you can set to lt b gt IM 19B01E04 02E lt 4 Operation gt 4 1 4 4 1 Operation After mounting and wiring have been completed you need only turn on the power to set this instrument in operation Before beginning operation you should first perform the inspections and check in Section 4 2 Note that no operator actions or manipulations are required when this instrument is operating Components Note The figure shows the Model PH201G ACI B distributor The PH201G AO B TB lacks a power cord with a ground plug having instead a power connection terminal board on the internal unit Input output terminal board Q Internal unit Terminal cover and handle for pulling out Rack case internal unit Multipin connector Grounded power plug Contact signal terminals Figure 4 1 Components IM 19B01E04 02E 4 2 lt 4 Operation gt 4 2 Pre Operation Checks Before beginning operation inspect check the following Items 1 Pull out the internal unit and check that the fuse installation in the fuse holder at the rear of the internal unit is of the proper rating for the power source When returning the internal unit to the rack case make sure that the connector that connects the internal
15. ry A CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices A IMPORTANT Indicates that operating the hardware or software in this manner may damage it or lead to system failure A NOTE Draws attention to information essential for understanding the operation and features IM 19B01E04 02E iv lt INTRODUCTION gt 4 After sales Warranty E Do not modify the product E During the warranty period for repair under warranty consult the local sales representative or service office Yokogawa will replace or repair any damaged parts Before consulting for repair under warranty provide us with the model name and serial number and a description of the problem Any diagrams or data explaining the problem would also be appreciated e If we replace the product with a new one we won t provide you with a repair report e Yokogawa warrants the product for the period stated in the pre purchase quotation Yokogawa shall conduct defined warranty service based on its standard When the customer site is located outside of the service area a fee for dispatching the maintenance engineer will be charged to the customer m In the following cases customer will be charged repair fee regardless of war ranty period Failure of components which are out of scope of warranty stated in instruction manual Failure ca
16. uble is suspected IM 19B01E04 02E 6 2 lt 6 Trouble shooting gt 6 1 Troubleshooting Flowchart Communication error Is the 2 wire YES cable shielded NO Change to a shielded wire Is signal update taking place Is output 0 or below Does update take YES too much time Are ls the 5 communications s the fuse open ON at the 2 wire transmitter Replace fuse and recheck See Section 5 3 Check the noise on the 2 wire line Is output 100 or above Input output accuracy problem NE YES Recheck the Replace the main error condition card and recheck NO End gt Replace the power unit and recheck NO End Recheck the error condition IM 19B01E04 02E lt 6 Trouble shooting gt 6 3 6 2 Part Replacement Procedure The following shows the disassembly procedures to be used when replacing parts Disassembly should be limited to a minimum disassemble carefully and no more than necessary To reassemble after replacing a part perform the disassembly procedures in reverse order Power unit Figure 6 1 PH201G Distributor Construction Drawing 6 2 1 Power Unit Removal 1 Remove connector 3 from 1 2 Remove screw 4 in two places 3 Power unit 1 can be removed by pulling it out from main card 5 The card 5 and power unit 1 are connected by a connector 6 2 2 Main Card Removal 1 Remove screw 6 in si
17. used by usage of software hardware or auxiliary equipment which Yokogawa Electric did not supply Failure due to improper or insufficient maintenance by user Failure due to modification misuse or outside of specifications operation which Yokogawa does not authorize Failure due to power supply voltage frequency being outside specifications or abnormal Failure caused by any usage out of scope of recommended usage Any damage from fire earthquake storms and floods lightning disturbances riots warfare radiation and other natural changes m Yokogawa does not warrant conformance with the specific application at the user site Yokogawa will not bear direct indirect responsibility for damage due to a specific application m Yokogawa Electric will not bear responsibility when the user configures the product into systems or resells the product Maintenance service and supplying repair parts will be covered for five years after the production ends For repair for this product please contact the near est sales office described in this instruction manual IM 19B01E04 02E lt CONTENTS gt v PH201G Style B Distributor IM 19B01E04 02E 6th Edition CONTENTS INTRODUCTION WEE i For the safe use of this equipment esser ELLE ELLER ii After sales Warranty ET iv 1 ENEE een 1 1 1 1 Standard Specifications sees rr NEE LEE 1 1 1 2 Model and Suffix Codes s seere ELLE ELL nana ana rnne nene anne 1 2
18. ut Yokogawa products you can visit Yokogawa s home page at the following web site Home page http www yokogawa com an IM 19B01E04 02E
19. x places 2 Remove 5 from 1 and 7 6 2 3 Cover Removal 1 Cover 8 can be removed easily by spreading the rotating section IM 19B01E04 02E Customer Model PH201G B Maintenance DISTRIBUTOR Parts List ltem Parts No Qty Description 1 E9715YB Power Supply Unit for 100V Version 1 E9715YS 1 Power Supply Unit for 220V Version 2 A1609EF 1 Fuse 1A 3 Y9306JB 8 PanH Screw M3 x 6 4 K9312EF 1 Main Board Assembly 5 E9713CK 1 Cover 6 E9713EG 1 Cable Assembly for 100V Version E9713FS 1 Cable Assembly for 220V Version 7 S9079PB 1 Bushing YOKOGAWA All Rights Reserved Copyright O 1989 Yokogawa Electric Corporation CMPL 19B1E4 01E Subject to change without notice A 3rd Edition Mar 2012 Yokogawa Electric Corporation Revision Information e Title PH201G Style B Distributor e Manual No IM 19B01E04 02E Apr 2014 6th Edition Section 1 1 Addition of Regulatory Compliance Jun 2012 5th Edition Page layout changed by InDesign Feb 2010 4th Edition Some of illustrations has been replaced more clearly drawings no contents changed Jul 2007 3rd Edition All over revised Addition of For the safe use of this equipment and After Sales Warranty Sec 1 Overview revised corresponding to GS CMPL 19B1E4 01E revised to 2nd ed some parts added Mar 2002 2nd Edition Some error correction Nov 2000 1st Edition Newly published m If you want to have more information abo